PDF

1.0.15 Version Software Release Notes
Cisco SES Controller Software
About These Release Notes
Cisco documentation and additional literature are available in a CD-ROM package, which ships with
your product. The Documentation CD-ROM, a member of the Cisco Connection Family, is updated
monthly. Therefore, it might be more current than printed documentation. To order additional copies of
the Documentation CD-ROM, contact your local sales representative or call customer service. The
CD-ROM package is available as a single package or as an annual subscription. You can also access
Cisco documentation on the World Wide Web at http://www.cisco.com, http://www-china.cisco.com, or
http://www-europe.cisco.com.
If you are reading Cisco product documentation on the World Wide Web, you can submit comments
electronically. Click Feedback in the toolbar, select Documentation, and click Enter the feedback form.
After you complete the form, click Submit to send it to Cisco. We appreciate your comments.
About the 1.0.15 Release
The 1.0 software release supports the Cisco WAN switching products: BPX 8600 series with SES
controller.
Software Release 1.0.15
Service Expansion Shelf (SES) PNNI and SVC Controller
Release 1.0.15 of the SES controller is compatible with the BPX 8600 series software Release 9.3.11
and with the later 9.3 releases. The SES controller is connected to the BPX 8600 series switch via a
BXM-155 (or T3/E3) port configured as a trunk. Redundant SES systems contain two controller cards
which offer APS protection on the ports connecting to the BPX.
Corporate Headquarters:
Cisco Systems, Inc., 170 West Tasman Drive, San Jose, CA 95134-1706 USA
Copyright © 2001. Cisco Systems, Inc. All rights reserved.
October 19, 2001 78-11020-08
About the 1.0.15 Release
Feature Overview
The SES controller is a VSI (Virtual Switch Interface) controller which provides a BPX 8600 series
wide-area switch the capability to create Switched Virtual Circuits (SVCs) and Soft Permanent Virtual
Circuits (SPVCs) using the UNI and PNNI protocols. One SES is required for each BPX 8600 series
node that will be originating, transporting, or terminating SVC/SPVC connections. The SES is offered
in redundant or non-redundant configurations.
Detailed Feature Information
As networks grow in size, PNNI becomes a critical element in the ability to scale a network. PNNI
provides a standard, interoperable, and scalable method to grow PVC (SPVC) networks to large sizes.
In addition, applications such as voice, video, and LAN require WAN switches to provide dynamic
connection capabilities in the form of SVCs. The SES provides the BPX 8600 series switch with a
centralized controller for establishing SPVCs and SVCs in both BPX 8600 series networks and in mixed
vendor environments. The BPX 8600 series switch in combination with the SES Controller
(Release 1.0) supports the following features:
•
ATM UNI 3.0/3.1 (CBR, VBR, UBR)
•
Point to Point SVCs, SPVCs, and SPVPs
•
PNNI 1.0 Single Peer Group
•
IISP with PNNI Inter-networking
•
E.164 & AESA/NSAP (DCC, ICD, E.164) addressing
•
Address filtering (source and destination)
•
ILMI 4.0
•
SPVC and SPVP endpoint provisioning (incl. ABR)
•
OC-3/STM-1, T3/E3 interfaces
•
OC-12/STM-4 interfaces
•
Intelligent CAC
•
Call Processor Redundancy (calls stable across switchover)
•
APS on controller uplinks to BPX
•
Connection and Path Trace facilities
•
Integrated management via CWM, SNMP MIBs
•
50K connections (SVC+SVP+SPVC+SPVP) per node
•
100K max endpoints per node (if all 50K conns are DACS)
•
99 UNI/PNNI SVC ports per node
•
100 calls per second
•
Dynamic partitioning and soft partitioning
•
SPVC support on feeder trunks
•
Dedicated Q-bin for control signalling
•
Graceful upgrade from SES PNNI 1.0.12 and 1.0.13 to l.0.14
1.0.15 Software Release Notes for the SES Controller
2
October 19, 2001 78-11020-08
Clarifications
Clarifications
N/A
Upgrade from SES 1.0.12, 1.0.13, or 1.0.14 to SES 1.0.15
This section covers the procedure for upgrading the Backup Boot and Runtime for the following
hardware:
Note
1.
Redundant Controller Card
2.
Single Controller Card (the PXM)
Some connectionions may take up to 60 minutes to recover after the controller is reset. For
more information, see the “Limitations” section on page 9.
Upgrade the Backup Boot Image
This section provides instructions for upgrading the Backup Boot images from 1.0.12/1.0.13/1.0.14 to
1.0.15. Boot upgrade can be graceful or non-graceful, depending on the type of card to be upgraded and
the configuration of the node.
Note
Since SES 1.0.13, 1.0.14 and 1.0.15 are using the same Boot image,(1.0.13, check software
compatibility matrix), there is no need to upgarde Boot image if it is upgarded from 1.0.13
or 1.0.14. Please skip the backup boot upgarde procedure and upgarde the run time image.
If SES is upgraded from 1.0.12 to 1.0.15, then it requires upgrade the Boot image before
the Runtime Image. Please use the boot image from the 1.0.13 Release.
Backup Boot Upgrade Procedure for Redundant Systems
Note
The procedure for upgrading the boot on active controller cards is the same procedure for
ugrading the boot on redundant controller cards. The difference is that you need to do this
procedure on the standby card and not on the active card, thus keeping the node in service
while doing the upgrades. Before you upgrade, FTP new Backup Boot firmware,
pxm1_001.000.013.000_bt.fw, to disk (should be the same as PXM FW procedure.)
To upgrade the boot on active controller cards on redundant systems, follow these steps:
Step 1
Use the following procedure to transfer the Backup Boot image to the card disk.
a.
From the SES, use the dspipif command at the active controller card to find the Node’s IP address.
The field internet address for lnPci 0 interface is the Node IP address.
b.
From the workstation containing the PXM Backup Boot image, enter ftp <Node IP address>.
c.
Enter the username cisco.
1.0.15 Software Release Notes for the SES Controller
October 19, 2001 78-11020-08
3
Upgrade from SES 1.0.12, 1.0.13, or 1.0.14 to SES 1.0.15
d.
Enter your password.
Note
Your password is supplied with the image.
e.
Enter cd C:/FW.
f.
Enter bin (for a binary transfer).
g.
Enter put <PXM Backup Boot image name>.
h.
Enter bye.
Step 2
From the SES, enter the dspcds command to determine standby card slot.
Step 3
Use the following procedure to verify that the Boot IP for both the active and standby card is unique:
a.
Use the bootchange command to find the Boot IP address for the active and standby card.
b.
Press enter until you see inet on ethernet (e). This is the Boot IP address for the active PXM1.
c.
To change this address to make it unique, type a new address at the inet on ethernet (e) prompt.
Note
Step 4
Changing the boot IP address on the active PXM1 also changes it on the standby
PXM1.
Use the cc command to change to the standby card.
ses1.1.PXM.a> cc 2
Step 5
From shellConn on the standby card, follow this procedure:
a.
Type sh to go to the shellConn.
ses1.2.PXM.s> sh
b.
issue sysBackupBoot command.
PXM1> sysBackupBoot
c.
Step 6
Press Return after you see disk sync message to get back to active PXM.
Exit or open a new telnet window and telnet into standby IP host inet address from Step 3. An alternate
way to get to the standby card is via the console port on the standby. Use the following procedure to reset
the card:
a.
Verify that the card is at the pxm1bkup> prompt. If it is not, reissue the sysBackupBoot shellConn
command on the standby card.
b.
Enter the sysPxmRemove command.
pxm1bkup>sysPxmRemove
After you issue the sysBackupBoot command, it takes about one minute for the active PXM to reset
the card. If the active PXM resets the standby PXM, wait until it comes to the standby state
(approximately four or five minutes), then telnet into the standby and repeat Step 5. After the
sysPxmRemove command is issued the active PXM can not reset the standby.
Step 7
Issue the cd C:/FW” command from pxm1bkup> prompt to get the FW directory.
pxm1bkup>cd “C:/FW”
1.0.15 Software Release Notes for the SES Controller
4
October 19, 2001 78-11020-08
Upgrade from SES 1.0.12, 1.0.13, or 1.0.14 to SES 1.0.15
Step 8
Enter the ls command to verify that the boot firmware file is there.
pxm1bkup>ls
Step 9
Enter the sysFlashBootBurn boot firmware file name command
pxm1bkup>sysFlashBootBurn“pxm1_001.000.013.000_bt.fw”
a.
Enter Y for Yes.
b.
When the pxm1bkup> prompt returns, issue the reboot command.
Flash Download completed...
value = 0 = 0x0
pxm1bkup> reboot
Step 10
Step 11
Login to active PXM.
a.
Enter the dspcds command to ensure the standby is in standby state.
b.
Enter the dspcd <standby slot #> command to verify the firmware was loaded successfully.
Load the Backup Boot onto the active PXM.
a.
Enter the switchcc command to change cards.
ses1.1.PXM.a> switchcc
b.
Login to the SES controller.
c.
Perform Step 5 through Step 10 on the new standby PXM.
Upgrade the Backup Boot on Non-Redundant Systems
The upgrade of the boot on a non-redundant controller card is non-graceful. This means the traffic gets
disrupted on the card during this operation. The upgrade can only take place when the card is in the
BOOT stage. Because there is only one controller card, there will be a node outage as well.
For non-redundant systems, follow these steps to upgrade the Backup Boot:
Step 1
Transfer Backup Boot image to the card disk using ftp as follows:
a.
From the SES, use the dspipif command at the active controller card to find Node’s IP address.
The field internet address for the lnPci 0 interface is the Node IP address.
b.
From the workstation containing the PXM Backup Boot image, enter the ftp <Node IP address>
command.
c.
Enter the username cisco.
d.
Enter your Password
Note
Step 2
Your password is supplied with the image.
e.
Enter cd C:/FW.
f.
Enter bin (for binary transfer).
g.
Enter put <PXM Backup Boot image name>.
h.
Enter bye.
Log in to the SES.
1.0.15 Software Release Notes for the SES Controller
October 19, 2001 78-11020-08
5
Upgrade from SES 1.0.12, 1.0.13, or 1.0.14 to SES 1.0.15
Step 3
At the shell, execute the sysBackupBoot command to put the controller card into the PXM Backup
prompt stage.
pxm1>sysBackupBoot
The PXM card resets.
Step 4
Login to the PXM.
Step 5
Enter the cd FW command at the pxm1bkup> prompt to get the FW directory.
pxm1bkup>cd “C:/FW”
Step 6
Enter ls command to verify the boot firmware file is there
pxm1bkup>ls
Step 7
Enter sysFlashBootBurn boot firmware file name command.
pxm1bkup>sysFlashBootBurn”pxm1_001.000.013.000_bt.fw”
Proceed as follows:
a.
Enter Y for Yes
b.
At the pxm1bkup> prompt, enter the reboot command.
pxm1bkup> reboot
The node resets.
c.
Login to the node.
Step 8
Login to active PXM
Step 9
Use the dspcd <active card> command to determine if the upgrade was successful.
ses1.1.PXM.a> dspcd 1
Upgrade the SES PNNI Runtime Image
This section provides instructions for upgrading the Runtime Images from 1.0.12/1.0.13/1.014 to 1.0.15.
The upgrade of the Runtime on the redundant controller card is graceful. This means the traffic will not
be disrupted. The new Runtime Image for 1.0.15 is pxm1_001.000.015.000_ses.fw.
Upgrade the Runtime Image on Redundant Systems
Follow these steps to upgrade the Runtime Image on redundant systems:
Step 1
Use FTP to transfer the Runtime Image to the card disk.
a.
Use dspipif at the active controller card to find Node’s IP address.
The internet address field is the Node IP address.
b.
Enter ftp <Node IP address>.
c.
Enter the username cisco.
d.
Enter your password.
1.0.15 Software Release Notes for the SES Controller
6
October 19, 2001 78-11020-08
Upgrade from SES 1.0.12, 1.0.13, or 1.0.14 to SES 1.0.15
Note
Your password is supplied with the image.
e.
Enter cd C:/FW.
f.
Enter bin (for binary transfer).
g.
Enter put <PXM Runtime Image name>.
h.
Enter bye.
Step 2
Enter the dspcds command to determine the standby slot.
Step 3
Enter the loadrev <standby slot> <image version> command to set the new version of run-time Image
on controller card, as in the following example:
ses1.1.PXM.a>loadrev 1 1.0(15.0)
The standby card is reset and will come up in the new revision.
Step 4
When the standby card is in the STANDBY state, execute the runrev <standby slot> <image version>
command to run the new version of Runtime Image on the controller card, as in the following example:
ses1.1.PXM.a>runrev 1 1.0(15.0)
The active card resets and the standby takes over as active. Both cards are running the new revision.
Step 5
When the standby card is in STANDBY again, you can use the abortrev <standby slot> <image version>
command to abort this upgrade if needed, as in the following example:
ses1.1.PXM.a>abortrev 1 1.0(15.0)
Step 6
Execute the commitrev <standby slot> <image version> command to commit the new version of
Runtime Image of controller card, as in the following example:
ses1.1.PXM.a>commitrev 1 1.0(15.0)
Step 7
The the dspcd command to verify successful upgrade.
ses1.1.PXM.a>dspcd 1
ses1.1.PXM.a>dspcd 2
Runtime Upgrade Procedure for Non-Redundant Systems
The upgrade of the Runtime on the a non-redundant controller card is non-graceful. That means the
traffic gets disrupted on the card during this operation.
For non-redundant systems, follow these steps.
Step 1
Use FTP to transfer the Runtime Image to the card disk as follows:
a.
Use dspipif at the active controller card to find Node’s IP address.
The internet address field is the Node IP address.
b.
Enter ftp <Node IP address>.
c.
Enter the username cisco.
d.
Enter your password.
1.0.15 Software Release Notes for the SES Controller
October 19, 2001 78-11020-08
7
Upgrade from SES 1.0.12, 1.0.13, or 1.0.14 to SES 1.0.15
Note
Step 2
Your password is supplied with the image.
e.
Enter cd C:/FW.
f.
Enter bin (for binary transfer).
g.
Enter put <PXM Runtime Image name>.
h.
Enter bye.
Set the new version of Runtime Image on controller card as in the following procedure:
a.
Enter the loadrev <slot> <image version> command as in the following example:
ses1.1.PXM.a>loadrev 1 1.0(15.0)
Note
No cards will reset.
b.
Reply Yes to the proceed question.
c.
Enter the dspcd command in the following example:
ses1.1.PXM.a>dspcd 1
The secondary revision on the PXM is set to new image version.
Step 3
Enter runrev to run the new version of Runtime Image on controller card.
a.
runrev <slot> <image version>
ses1.1.PXM.a>runrev 1 1.0(15.0)
b.
Card will reset and will run the new revision when it returns.
c.
dspcd
Example: ses1.1.PXM.a>dspcd 1
Step 4
At this point you can still abort this upgrade if needed. Use abortrev if needed.
ses1.1.PXM.a>abortrev 1 1.0(15.0)
Step 5
Execute commitrev to commit the new version of Runtime Image of controller card
a.
commitrev <slot> <image version>
commitrev 1 1.0(15.0)
b.
dspcd 1
ses1.1.PXM.a>dspcd 1
Procedure for Upgrading BXM Firmware and 9.3 Switch Software Releases
Perform the following steps:
Step 1
Upgrade BXM firmware to MFM. See Release Notes for BXM MFM firmware in Appendix A.
Step 2
Upgrade BCC switch software to Release 9.3.11.
1.0.15 Software Release Notes for the SES Controller
8
October 19, 2001 78-11020-08
Notes & Cautions
Note
Please use SES PNNI 1.0.13 Backup boot, pxm1_001.000.013.000_bt.fw.
Note
Please refer to 9.3.11 Release Notes for BCC switch software upgrades
SES Controller Bring Up Procedure
For detailed procedure changes, please see the on-line Cisco SES PNNI Controller Software
Configuration Guide at:
http://www.cisco.com/univercd/cc/td/doc/product/wanbu/ses/pnnicnf/index.htm
Compatible Releases
SES PNNI version 1.0.15 has been certified with the following releases:
•
BPX SWSW version 9.3.11 or later (see S/W Compatibility Notes Matrix, first and second bullets)
•
BXM Firmware version MFN or later (see S/W Compatibility Notes Matrix, first and second bullets)
•
Cisco View version 5.0
•
CWM version 10.4.10
•
BCC-3-64
•
BPX-BCC-4V or BPX-BCC-4V/B
•
MGX 8850 R1 1.1.32 and 1.1.34 (1.1.34 is not available as of 6/20/2001)
•
MGX 8220 5.0.16
For further information on the BXM card, please see Appendix A.
Note
The SES PNNI 1.0.14 is compatible with MFM BXM (See Table 1 for more information.)
Notes & Cautions
Limitations
Release 1.0.15 of the SES has the following system limitations:
•
If ports are brought up and down many times between the time the controller is reset (e.g. via
resetsys) and the time it is upgraded, there is a chance that some connection updates did not get to
the standby card (See CSCdt78006). As the system switches over during upgrade and the new active
card detects a mismatch between the PXM and the BXM, resync is triggered between PXM and the
BXM where mismatched connections will be deleted and re-added. In the worst case scenario
where all connections terminate on just one port and if there were 40000 connections, it may take
up to 60 minutes for the last connection to recover.
1.0.15 Software Release Notes for the SES Controller
October 19, 2001 78-11020-08
9
Notes & Cautions
•
The number of connections is always less then the max con value used in the addpart command.
This is due to the fact that each card needs 1 LCN for control VC. If it is PNNI, there is another VC
for RCC. Therefore, if the max con value is set to 9000 connections, only 8999 or 8998 connections
can be added.
•
The dspcons command does not support ranges for vpi/vci. If the users enters dspcons -vpi 2, this will
display all SPVCs with vpi >= 2 not just the SPVCs with vpi = 2.
•
The Route Optimization algorithm is node-by-node and based on connection mastership; it is not
distributed across the node. For example, if Node A is connected to Node C via Node B, Node A
only knows about the connections from A to B and not about the connections from B to C. This
limitation will not allow Node A to use route optimization for connections from B to C.
•
There is no check for preventing multiple masters of SPVC conns from pointing to the same slave.
When provisioning a second connection to a slave UPI/UCI that is already used, there will be no
warning at the CLI that the connection has failed.
•
In a large network, it can take up to 30 seconds (or more) to be able to accept new calls after a
switchover. This is because PNNI relearns the topology on a switchover. For the existing
connections, the control plane and the data plane doesn’t get affected on a switchover.
•
Node names are not required for each node. A node name can be entered and is distributed but there
is no check for uniqueness of it within the network. Multiple nodes with the same name doesn’t
cause any inconsistencies in PNNI routing.
•
BXM interface (OC and T3) traffic policing only works if cell rate is higher than 50 cells per second.
•
When master endpoint is deleted, slave endpoint is also deleted.
•
Starting from BXM firmware release MFL, due to limited memory space on the BXM card and code size
increasing, channel statistics level 0 is no longer supported on BXM cards (BXM-155-4, BXM-155-8,
BXM-622, BXM-622-2, BXM-T3-8, BXM-T3-12, BXM-E3-8, BXM-E3-12 models). When BXM card
firmware is upgraded to MFL or any post MFL release, regardless how many connections have been
provisioned, channel statistics level 0 is no longer supported. If a BXM card has channel statistics level
0 turned on, to upgrade its firmware to MFL or any post MFL release, two upgrade paths can be taken:
•
Change the BXM card to run channel statistics level 1. Statistics level 1 supports a maximum of 16K
connections on a card. If a card has more than 16K connections configured, some connections must
to be relocated to other BXM interfaces to reduce the total number of connections to be less than
16K. Reset the card after changing to statistics level 1.
•
Upgrade the BXM card to the BXM-E card. The BXM-E card can continue running statistics level
0. Statistics level 0 can support a maximum of 32K connections on a card.
Notes/Recommendations
•
Provisioning of SPVC connections is performed using a two-ended provisioning model, similar to the
way connections are provisioned using AR. This provisioning model enables more robust management
(including fault conditions) of both connection endpoints than does a model which only provisions the
master endpoint.
In order to establish a DAX or a routed SPVC, users need to first provision the slave endpoint then
provision the master endpoint to set up a connection. The traffic parameters and QoS parameters on
both master and slave endpoints must match in order to have a SPVC established.
Interoperability with other equipment using a single-ended provisioning model is supported, but the
provisioning must be done carefully. The operator must ensure that the slave provisioning matches
exactly with the parameters signaled from the master endpoint.
1.0.15 Software Release Notes for the SES Controller
10
October 19, 2001 78-11020-08
Compatibility Notes
•
For each SPVC add, delete, or modification, SES will generate a trap to CWM so that CWM can
sync up connection management database with SES/BPX switch in real time. The trap information
exchange between CWM and SES is handled by inter-system communication protocol. The
trap-handling rate normally is much slower than the script driven SPVC setup or delete rate. When
a user uses a script to do burst SPVC addition or deletion, due to limited trap queue size, the trap
queue may overflow and cause trap loss. If burst SPVC add/delete size is more than 1K connections,
it is recommended that user to pace his setup/delete rate to be 1 connection per sec to avoid trap loss.
•
The minSvccVci value for the partition is defaulted to 35 and the vci 33 and 34 are marked for future
control plane use.
•
In the case of obtaining optimized routes while performing PNNI on demand route lookup it is
recommended to change the routing policy to best fit option.
Required Workarounds
N/A
Compatibility Notes
Table 1
SES Controller - Hardware Compatibility Matrix
Latest Boot Code Version
Minimum
Boot Code
Version
BXM
Firmware
SWSW
CWM
1.0.10
pxm1_001.000.001.000_bt.fw
1.0.01
MFH
9.3.10
10.3
PXM1
1.0.11
pxm1_001.000.011.001_bt.fw
1.0.11
MFJ
9.3.10
10.4
PXM1
1.0.12
pxm1_001.000.011.001_bt.fw
1.0.11
MFL
9.3.11
10.4
PXM1
1.0.13
pxm1_001.000.013.000_bt.fw
1.0.13
MFM
9.3.11
10.4
PXM1
1.0.14
pxm1_001.000.013.000_bt.fw
1.0.13
MFN
9.3.11
9.3.24
10.4.10
PXM1
1.0.15
pxm1_001.000.013.000_bt.fw
1.0.13
MFN
9.3.11
9.3.24
10.4.10
Board Pair
SES PNNI
Version
PXM1
Table 2
SES Controller - Hardware Compatibility Matrix
OC3 Combinations (Shipping/Customer Configurations)
No.
Description
Front Card (PXM)
PXM UI Back Card
PXM Uplink Back Card
1
MMF OC3
SES-PXM-CNTL-4-155
PXM-UIA
MMF-4-155
(with 4 port OC3)
Rev: A0 or later
Rev: A0 or later
SES-PXM-CNTL-4-155
PXM-UIA
SMFIR-4-155
(with 4 port OC3)
Rev: A0 or later
Rev: A0 or later
P/N 800-06454-01 or later
2
SMF-OC3,
Intermediate
Range
P/N 800-06454-01 or later
SMFIR-4-155/B
Rev: A0 or later
1.0.15 Software Release Notes for the SES Controller
October 19, 2001 78-11020-08
11
Compatibility Notes
T3/E3 Combinations (Shipping/Customer Configurations)
No.
Description
Front Card (PXM)
PXM UI Back Card
PXM Uplink Back
Card
1
T3
SES-PXM-CNTL-2T3E3
PXM-UIA
BNC-2T3
(with 2 port T3E3)
Rev: A0 or later
Rev: A0 or later
SES-PXM-CNTL-2T3E3
PXM-UIA
BNC-2E3
(with 2 port T3E3)
Rev: A0 or later
Rev: A0 or later
P/N 800-06699-01
2
E3
P/N 800-06699-01
Table 3
Feeder SW tested with SES SPVCs - Hardware Compatibility Matrix
Feeder
MGX 8850 R1
Release
1.1.34
HW Cards
MGX 8220
5.0.16
PXM-1
FRSM-4T1/4E1/4T1-C/4E1-C
PXM1-2T3E3
SRM-T1E1
PXM1-4OC3
SRM-3T3
PXM1-OC12
CESM-4T1/4E1
SRM-3T3
CESM-8T1/8E1
CESM-8E1
AUSM-4T1/4E1
CESM-8T1
FRSM-8T1/8E1
AUSMB-8E1
AUSM-8T1/8E1
AUSMB-8T1
AUSMB-8T1/8E1
CESM-T3
AUSMB-8T1/8E1
CESM-E3
FRSM-HS1
FRSM-8E1
FRSM-HS1/B
FRSM-8T1
FRSM-HS2
FRSM-HS2
IMATM-T3T1/E3E1
FRSM-2CT3
IMATMB-T1/E1
FRSM-2T3
FRSM-2E3
FRSM-HS1/B
VISM-8T1
VISM-8E1
RPM
RPM-PR
1.0.15 Software Release Notes for the SES Controller
12
October 19, 2001 78-11020-08
Known Anomalies
Known Anomalies
The following is the list of known anomalies in this SES PNNI delivery. Included with each is a brief
discussion of the problem. A more in depth discussion is available in the release note enclosure of the
problem record in Bug Navigator.
The following bugs are applicable on to the PXM software.
Table 4
PXM Software Bugs
Bug ID
Description
S1 BUGS
S2 BUGS
CSCdt08059
Symptoms:
Telnet daemon allowed user access into switch without authentication
Conditions:
While in boot mode, you can telnet to the node. Access via telnet during boot mode
is not restricted.
Workaround:
None.
CSCdt12655
Symptoms:
Too many stat collection ftp errors.
Conditions:
Unknown
Workaround:
None
CSCdt78006
Symptoms:
Conditions:
Workaround:
CSCdu19130
Symptoms:
Node with 50K routed connections crashed, and there was no response to some CLI
commands, such as dsppnports and dspcons. After executed the abortrev command
on the other node in the network.
Conditions:
There are 50K routed connections between node pswpop7/pswbpx2 and
orses18/svcbpx23 via node pswpop6/pswbpx6. I did loadrev and runrev to upgrade
a the orses18 node from 1.0 to 1.1. Everything was fine after upgrade. Then I did
abortrev to bring theorses18 node back to the 1.0 image. After abortrev was
executed on the pswpop7 node, it suddenly crashed. Many tasks were deleted. No
responses to some cli commands like dsppnports, dspcons, dspconinfo, etc. but
dspdate, dsplogs, dsperrs worked fine.
Workaround:
None.
1.0.15 Software Release Notes for the SES Controller
October 19, 2001 78-11020-08
13
Known Anomalies
Table 4
PXM Software Bugs
Bug ID
Description
CSCdu22913
Symptoms:
The SSI_SRAM_WIN_TIMEOUT Redman Error causes the standby PXM1 reset.
Condition:
There are about 50k routed SPVC connections between two Orion/BPX nodes. One
Orion node has redundant PXM1 cards. Pull out the Y-cable on the feeder trunk. The
RedmanError SSI_SRAM_WIN_TIMEOUT causes standby PXM1 reset.
Workaround:
Unknown.
CSCdu24540
Symptoms:
The dbsvr command failed to upgrade after standby reset when used script to
dncon/upcon.
Condition:
There were about 50K routed spvc connection between node orses18/svcbpx23 and
node pswpop7/pswbpx2. Ran script to dncon/ upcon on orses18, at the same time
reset standby PXM1 on orses18. dbsvr failed to upgrade.
Workaround:
Unknown.
S3 BUGS
CSCds74052
Symptoms:
Given a redundant SES node, pull out the trunk back-card from the active PXM's slot.
This causes the active PXM to reboot and the standby PXM to take over as the active
front-card. The previously-active PXM card should come up as the standby card but
instead, it keeps rebooting.
Condition:
Not known as yet. It is suspected that some task is trying to access the NOVRAM on
the (absent) trunk back-card.
Workaround:
None. Do not pull the trunk back-card out while the front-card is in either the active
or standby role.
S4 BUGS
CSCdt85179
Symptoms:
Connectivity to BPX is lost. LMI root task has been deleted on the SES.
Conditions:
This happens when the “Run Protocol By card” option is run on the BXM, causing
LMI to run on the BXM instead of the BCC.
Workaround:
Currently, BPX does not support LMI 4 on BXM, whereas it is required to run 4.0 on
SES (because of IP connectivity features needed on the SES). Hence, DO NOT RUN
Protocol by Card on the BXM.
1.0.15 Software Release Notes for the SES Controller
14
October 19, 2001 78-11020-08
Problems Fixed in Release 1.0.15
Problems Fixed in Release 1.0.15
Table 5
PXM Software Bugs
Bug ID
Description
S1 BUGS
CSCdu39060
Symptoms:
Active PXM resets during a loadrev to upgrade Standby.
Conditions:
DbSvrIO Tlb Load Exception on Active PXM.
Workaround:
None
Problems Fixed in Release 1.0.14
Table 6
PXM Software Bugs
Bug ID
Description
S2 BUGS
CSCds78285
Symptoms:
Connections in failed or BuildingVC state.
Conditions:
CAC policy was not downloaded to some of the BXMs.
Workaround:
None
CSCdu65624
Symptom:
As the standby PXM coming up after loadrev on a node. Ram Sync Err occurred and
the standby PXM went to Failed state.
Condition:
Upgrading the node.
Workaround:
None
Known Anomalies from Previous Releases
The following anomalies were identified in previous releases.
Bug ID
Description
CSCdt33599
Closed - problem was due to a wrong configuration.
1.0.15 Software Release Notes for the SES Controller
October 19, 2001 78-11020-08
15
Problems Fixed in Release 1.0.13
CSCdt37734
Un-reproducible. Failed to configure SPVC Prefix.
CSCdt45706
Un-reproducible. Standby PXM has a state of “mismatch”.
CSCdu32539
Duplicate of CSCds74267 - fixed in 1.0.13
Problems Fixed in Release 1.0.13
Table 7
PXM Software Bugs
Bug ID
Description
S1 BUGS
CSCds75999
Symptoms:
The SSCOP reset happens after switch over to standby, and connections get derouted.
Conditions:
During any resync, failures occur on control VCs in the active card. The standby
doesn't know the failure and doesn't unbind on the LCNs. This causes an
inconsistency with the VSI proxy and causes the SSCOP to go down during
switchover.
Workaround:
None.
CSCds76260
Symptoms:
Traps are not received from the switch. Some traps get lost, or no traps are delivered.
Conditions:
The following conditions result in a standalone PXM system:
1.
On a redundant system, the standby PXM card is reset.
2.
On a redundant system, the standby PXM is removed and never reinserted.
3.
On a standalone system, a standby PXM is removed, and never gets re-inserted.
4.
On a standalone system, a standby PXM is added, but fails.
Workaround:
When traps are not being received, reset the active pxm card.
Due to the bug introduced into the system, the trap client task flushes its queues and
sends a lost trap to the CWM/external world. The shm generates a card removal for
the standby PXM. In this event, flush the queues and stop sending out the traps. This
problem persists until you insert a standby card and a card becomes available for the
standby PXM, or until the active PXM card is rebooted.
Note
Any time we get a card unavail from the standby pxm, this state persists until
a card avail is received by the trap client task. Inserting a standby card and
unplugging it will cause us to get into this state.
1.0.15 Software Release Notes for the SES Controller
16
October 19, 2001 78-11020-08
Problems Fixed in Release 1.0.13
Table 7
PXM Software Bugs (continued)
Bug ID
Description
CSCds85557
Symptoms:
The standby card continuously resets.
Conditions:
This occurs when the operator replaces the standby card with a PXM which has an
upgrade configuration.
Workaround:
Execute the sysClrallcnf command on the standby PXM only.
CSCds90529
Symptoms:
SSCOP links go into a Release/Reset state, causing all the connections to be
rerouted/derouted or stay in fail state.
Conditions:
SSCOP and PNNI links could be reset or released due to errors while
re-synchronization is happening. The connections are being removed from the
Service Module (AXSM) causing SSCOP and PNNI failures.
Workaround:
Down the port and up it again.
CSCdt16078
Symptoms:
SPVCs derouted on newly active PXM card.
Conditions:
This problem is found in MGX 8850 shelf after runrev.
Workaround:
Waiting for all the connections to be rerouted.
CSCdt36063
Symptoms:
The dsppnports command on a PXM card does not show the output.
Conditions:
On executing dsppnports on a PXM card, pnCcb task is suspended.
Workaround:
Switchover to a standby PXM, or enter the resetsys command on the active PXM
card.
CSCdt70757
Symptoms:
SPVC Connections did not route after node upgrade.
Conditions:
Upgrading the node.
Workaround:
None.
1.0.15 Software Release Notes for the SES Controller
October 19, 2001 78-11020-08
17
Problems Fixed in Release 1.0.13
Table 7
PXM Software Bugs (continued)
Bug ID
Description
CSCdt74499
Symptoms:
The node rejects CLI commands.
Conditions:
This occurs when you execute the dsppnports and dsppnni-link commands.
Workaround:
None.
CSCdt87745
Symptoms:
When cong_display command is executed “outStanding status enquiry congestion” is
persistently on.
Conditions:
An edge node that had SPVC connections routed via this node was rebooted.
Workaround:
None.
CSCdt96649
Symptoms:
1. dspcons shows conn in FAIL state, but dspconinfo shows conn in OK state 2. Alarm
file contains status as clear 3. No trap is sent to CWM when a DAX conn in AIS
Conditions:
When an interface is failed
Workaround:
None
CSCdu17620
Symptoms:
PNNI tries to route a new call using VPI/VCI pair that has already been assigned to
an active call over the PNNI trunk.
Conditions:
UNKNOWN
Workaround:
Issue the resetsys command to clear this condition.
S2 BUGS
CSCds54946
Symptoms:
VP connections are slow to route.
Conditions:
Some deroute might have failed, causing some dangling VC in AXSM. What it means
that some VCs are left in use in AXSM.
Workaround:
After some time, RESYNC detects the error and connection is cleaned up at the
AXSM.
1.0.15 Software Release Notes for the SES Controller
18
October 19, 2001 78-11020-08
Problems Fixed in Release 1.0.13
Table 7
PXM Software Bugs (continued)
Bug ID
Description
CSCds68426
Symptoms:
Sometimes, after a non-graceful upgrade, some DAX SPVP stay in a failed state.
Conditions:
This condition can occur after a non-graceful upgrade which accompanies a system
reboot. Happens for DAX connections.
Workaround:
None Enter the dncon and upcon commands to recover the connection.
CSCds77133
Symptoms:
Calls fail to re-route. Release cause: user not responding.
Conditions:
This occurs when an ABR traffic congestion flag is set on a Via-node
Workaround:
PXM Switchover will remove the problem on the newly active PXM.
CSCds77137
Symptoms:
A connection is not routed with master state as down VSI half and not in any queue
and admin is up.
Conditions:
This occurs when you run the dncon, upcon, rrtcon commands while there are lots
of connections in the routing queue.
Workaround:
Run dncon and upcon commands again.
CSCds79085
Symptoms:
When the dsppnports command is executed, the interface is in the “building-vc”.
state.
Conditions:
Multiple AXSM switchovers lead to this problem.
Workaround:
Once the interface is in the “building-vc” state, enter dnpnport followed by
uppnport to bring the interface to oper-up.
CSCds86171
Symptoms:
Ports stay in ILMI query and do not go to operational status.
Conditions:
In cases of congestion or burning new firmware if ilmi responses are lost from the
card for all retries during resync.
Workaround:
Down and up port from SES controller should solve the problem.
1.0.15 Software Release Notes for the SES Controller
October 19, 2001 78-11020-08
19
Problems Fixed in Release 1.0.13
Table 7
PXM Software Bugs (continued)
Bug ID
Description
CSCds86265
Symptoms:
Summary display of tasks is awkward to get from CLI.
Conditions:
Always.
Workaround:
Enter the dsptask command as follows:
dsptask
CSCds86694
12
Symptoms:
When the resetcd command is given, an unexpected system reload occurs.
Conditions:
Unknown.
Workaround:
None.
CSCds87127
Symptoms:
SNMP does not respond, or lost traps occur after the switchcc command is executed
on the redundant node. This problem is very rare.
Conditions:
1.
When you execute the switchcc command on a node with a redundant PXM, the
standby PXM becomes active, but any communication with the switch via SNMP
does not get any response
2.
The standby PXM might drop the first few traps when it becomes active because
it could not transition fast enough.
Workaround:
None.
CSCds88236
Symptoms:
An SSCOP reset happens after a switch over to the standby, and connections get
derouted.
Conditions:
During any resync failures on control VCs in the active, the standby doesn't know the
failure and doesn't unbind on the LCNs. This causes an inconsistency with the VSI
proxy and causes SSCOP to go down during switchover.
Workaround:
None.
1.0.15 Software Release Notes for the SES Controller
20
October 19, 2001 78-11020-08
Problems Fixed in Release 1.0.13
Table 7
PXM Software Bugs (continued)
Bug ID
Description
CSCdt03684
Symptoms:
A pnport is stuck in building VC, preventing SVCs and new SPVCs from getting
routed.
Conditions:
The upport/dnport command was executed on an AXSM port to get rid of some
phony e-ais/rdi alarms
Workaround:
None.
CSCdt06911
Symptoms:
The pnport both side of the pnni-link goes to attempt state. The SSCOP on both sides
is in established state. There are no alarms etc on any of the pnport, SSCOP, port of
the line of both nodes.
Conditions:
The PNNI port goes into attempt when a delred, addred is followed very quickly by
a switchcc.
Workaround:
By disabling the PNNI node using cnfpnni-node disable, and re-enabling it the link
can be brought up. This is NOT service affecting.
CSCdt07085
Symptoms:
SPVCs stayed in conditioning state
Conditions:
The node terminating the master end of one of the two failed spvcs was rebuilt
Workaround:
UNKNOWN
CSCdt07366
Symptoms:
The pnport on the local side goes to vc building state and SSCOP
is in unknown state. The remote node shows that pnport is up and the pnni-link is in
attempt state.
Conditions:
The pnport which has Y-red configured goes to building vc state. The SSCOP is in
the unknown state on the local side. The condition occurred with switchcc after the
the Y-red is deleted.
Workaround:
Bringing the pnport down (dnpnport) and up (uppnport) the pnport
come out from the vc building state.
1.0.15 Software Release Notes for the SES Controller
October 19, 2001 78-11020-08
21
Problems Fixed in Release 1.0.13
Table 7
PXM Software Bugs (continued)
Bug ID
Description
CSCdt11521
Symptoms:
vsiProcessVxlCommitRsp: no leg, but has Pep error message keep pop up on PXM
Conditions:
Reset multiple AXSM cards
Workaround:
It'll stop generate error message after AXSM comes up
CSCdt12043
Symptoms:
After multiple switchcc failed to telnet to a node.
Conditions:
Disk IP address not configured for LAN (lnPci0). During switchover, no ARP
broadcast sent to declare new IP address <--> MAC address mapping.
Workaround:
Make sure the Disk IP address (lnPci0) of this node is configured.
CSCdt12816
Symptoms:
Adtech conformance tests for SSCOP give an inconclusive result
Conditions:
the Adtech does not expect a response to BGREJ PDU in idle state
Workaround:
None.
CSCdt14860
Symptoms:
dsplog shows some event log are getting dropped
Conditions:
This occurs when the same event is generated multiple times in a short period of time.
The default interval is 1 tick = 1/100 second
Workaround:
None.
CSCdt19936
Symptoms:
Port stuck in building vc
Conditions:
Power off/on or reset node
Workaround:
Issue dnpnport portID then uppnport portID command
1.0.15 Software Release Notes for the SES Controller
22
October 19, 2001 78-11020-08
Problems Fixed in Release 1.0.13
Table 7
PXM Software Bugs (continued)
Bug ID
Description
CSCdt22626
Symptoms:
CAC is set for ABR for 2%. Have 2 connections big PCR CBR connection and ABR
connection. If CBR is routed first, then ABR con is not able to route.
Conditions:
ABR connection is not routed due to no bandwidth although pnni has enough
bandwidth
Workaround:
dncon on the CBR connection rrtcon on ABR upcon on the CBR connection
CSCdt23284
Symptoms:
Dax connections go into failed state.
Conditions:
When upgraded from 2.1(0.15) to 2.1(0.30).
Workaround:
Down one of the pnni port and up again.
CSCdt27655
Symptoms:
The Cumulative RM fixed round trip time parameter (octet 9) is not included in the
ABR setup parameter.
Conditions:
When initiating an SPVC ABR call, the cumulative RM FRTT octet is not included
in the ABR setup parameter.
Workaround:
None.
CSCdt31293
Symptoms:
Able to add 2 master to the same slave endpoint for dax connections
Also, this will lead to dspcons mess-up
Conditions:
add slave endpoint
add master endpoint to slave endpoint NSAP address
add another master endpoint (with different vpi vci) to the same slave endpoint NSAP
address and vpi vci
Workaround:
None.
1.0.15 Software Release Notes for the SES Controller
October 19, 2001 78-11020-08
23
Problems Fixed in Release 1.0.13
Table 7
PXM Software Bugs (continued)
Bug ID
Description
CSCdt34888
Symptoms:
VBR3 and UBR2 routed SPVC connection remain in FAIL state. Dspcon on that
connection shows “Unsupported combination of traffic parameters” as the Last Fail
Cause.
Conditions:
If frame discard is requested on the VBR3 or UBR2 SPVC connections (via
addcon/cnfcon), then these connections fail to route.
Workaround:
Do not program frame discard on pep (addcon/cnfcon with frame discard disabled).
CSCdt37734
Symptoms:
Fail to configure SPVC prefix.
Conditions:
SPVC prefix can be configured only if there is no connection in the node.
Unfortunately, there are six dangling legs in CM for three dax connections.
Workaround:
None
Status:
Unreproducible
CSCdt37525
Symptoms:
cli command dnpnport/uppnport of NNI port timeout. pnRedman was busy sending
to standby while the standby is in failed status showing in dspcds. syncRam shouldn't
allow application (pnRedman) to send to standby when standby is in failed status.
Conditions:
p2spvc4.8.PXM.a > dspver
Image Type Shelf Type Card Type
Version Built On ---------- ------------------- ------------ ------------ Runtime
MGX
PXM45 2.1(50.43)A
Feb 1 2001, 03:54:17 Boot
MGX
PXM45 2.1(50.43)A The MGX(p2spvc4) node has a 100k SPVC routed connections.
Workaround:
None.
CSCdt38260
Symptoms:
pnport went into vc failure state
Conditions:
setrev was executed on AXSM
Workaround:
None.
1.0.15 Software Release Notes for the SES Controller
24
October 19, 2001 78-11020-08
Problems Fixed in Release 1.0.13
Table 7
PXM Software Bugs (continued)
Bug ID
Description
CSCdt38632
Symptoms:
Syntax for the command routeNetAdd failed
Conditions:
At the cli prompt type the command
Workaround:
None.
CSCdt41956
Symptoms:
SAR frame transmit failed and ssiFrameXmt failed error messages are recorded in
event log.
Conditions:
Switchcc executed every 8 minutes.
Workaround:
None.
CSCdt43448
Symptoms:
from dsppnports, there are failed three spvc connections at both orion node (svcpop2)
and MGX node(p2spvc4).
Conditions:
Both Orion node svcpop2 and MGX node p2spvc4 have redundancy cards and
multiple pnni interfaces. About 99K spvc connections are configured and routed on
the node. Upgraded the FW to 1.1(50.44)A and system went to reset. After reset
system, the spvc connections start to reroute. Once finished rerouting, there are still
three connections failed. Chi and Qian were looking into this problem and collecting
necessary informations. (02/12/2001)
Workaround:
None.
CSCdt44343
Symptoms:
Event log files are not ordered in chronological order
Conditions:
on a redundant node, as a card comes up in standby mode. The file number sequence
is off.
Workaround:
None.
CSCdt45643
Symptoms:
Route Op Start/Stop messages are dropped incorrectly.
Conditions:
None
Workaround:
None.
1.0.15 Software Release Notes for the SES Controller
October 19, 2001 78-11020-08
25
Problems Fixed in Release 1.0.13
Table 7
PXM Software Bugs (continued)
Bug ID
Description
CSCdt47978
Symptoms:
dbgcon command is available at cli level. Enabling it globally can increase load on
the CPU. The current fix prints a warning message.
Conditions:
Not applicable
Workaround:
None.
CSCdt50122
Symptoms:
Node-name missing at higher levels when dsppnni-node is done.
Conditions:
Execute the dsppnni-node command.
Workaround:
None.
CSCdt59596
Symptoms:
Trap 60078 (cwCoreCardSwitch) was sent with cwTrapSlotNumber and
cwTrapIndex in reversed order so old active slot number would be wrong.
Conditions:
The trap is sent after a PXM switchover.
Workaround:
None.
CSCdt66184
Symptoms:
addcon, dspcons, dspcon, delcon, cnfcon are only available at the
CISCO_GP access level.
Conditions:
Commands are available on AXSMS.
Workaround:
You must log in as cisco to access these commands.
CSCdt75586
Symptoms:
Control VC stays in attempt states. QE SAR shows discards/errors on the GLCN.
Conditions:
We suspect that QE VC queue is not purged when the connection is deleted. It causes
the cell memory leak in QE. Pretty soon the cell memory will reaches the threshold
so the incoming cell will get discarded.
Workaround:
Switchover to standby.
1.0.15 Software Release Notes for the SES Controller
26
October 19, 2001 78-11020-08
Problems Fixed in Release 1.0.13
Table 7
PXM Software Bugs (continued)
Bug ID
Description
CSCdt75394
Symptoms:
Alarms do not sync up during CWM cold start.
Conditions:
1. CWM cold start.
2. too many alarms in switch.
Workaround:
None.
CSCdt78822
Symptoms:
Memory is never freed.
Conditions:
Failure cases of dspconstats command.
Workaround:
None.
CSCdu00481
Symptoms:
ANYUSER can delcon/cnfcon.
Conditions:
ANYUSER level is just for checking status (dsp commands). But I found a user at
ANYUSER level can do both delcon and cnfcon.
Workaround:
Unknown.
S3 BUGS
CSCdp43597
Symptoms:
Confusing trap sent when voltage is above threshold.
Conditions:
When DC voltage is above threshold an event is logged that specifies an “Above
threshold” alarm. However, a “Below threshold” trap is generated.
Workaround:
None.
1.0.15 Software Release Notes for the SES Controller
October 19, 2001 78-11020-08
27
Problems Fixed in Release 1.0.13
Table 7
PXM Software Bugs (continued)
Bug ID
Description
CSCdp93160
Symptoms:
When errors are injected on the working line, the working line status changes from
OK to an alarm state (depending on the bit-error rate, the state could be SigF, ALM
or some other state). The protection line should still be OK and APS should switch
to the protection line.
If CSCdp93160 (this bug) happens, the errors injected on the working line also show
up on the protection line, causing its status to change from OK to one of SigF, ALM
or other similar alarm states. Therefore, the APS sub-system (wrongly) thinks that
both lines are in error and switches back and forth between the two as and when it
finds the protection line toggling between OK and alarm states. Due to this, traffic
may be impacted.
Conditions:
Unknown.
Workaround:
None.
CSCdr40795
Symptoms:
No command available for clearing connection statistics.
Conditions:
Clearing connection statistics.
Workaround:
None
CSCds10778
Symptoms:
Standby PXM gets reset by the active PXM.
Conditions:
Rerouting is going on massive scale, we have SPVC journaling also at the same time
and user executes provisioning commands which requires disk writes and standby
journaling updates. At that time sometimes standby is reset by active pnRedman.
Workaround:
When massive rerouting is going on, avoid too many provisioning commands on the
system.
CSCds12952
Symptoms:
Calls are released on the active card but not on the standby PXM.
Conditions:
Delete of a port goes to the standby card before bulk release calls does.
Workaround:
None.
1.0.15 Software Release Notes for the SES Controller
28
October 19, 2001 78-11020-08
Problems Fixed in Release 1.0.13
Table 7
PXM Software Bugs (continued)
Bug ID
Description
CSCds15154
Symptoms:
Port goes into Building VC
Conditions:
When configuring the signaling parameters for a given port. If sigvci and rccyci have
been changed and then brought back to their default values of 5 and 18, the port may
go to Building VC.
Workaround:
Down the port and up the port should bring the port to UP again.
CSCds55940
Symptoms:
Card alarm is generated when core redundancy is lost.
Conditions:
When core redundancy is disabled using cnfndparms.
Workaround:
None
CSCds62761
Symptoms:
SPVC are allowed to be added on failed PNNI interface.
Conditions:
When you run the addcon command on a failed PNNI interface.
Workaround:
Do not add an SPVC on a failed PNNI interface.
CSCds69318
Symptoms:
dspcds command output shows alarms.
Conditions:
When you execute the dspcds command on standby PXM card.
Workaround:
Ignore alarms displayed on the standby PXM card.
CSCds82118
Symptoms:
Control chars in file names' are printed as is during listing of the files.
Conditions:
Accidental creation of file(s) with control characters in its (their) name(s).
Workaround:
None.
1.0.15 Software Release Notes for the SES Controller
October 19, 2001 78-11020-08
29
Problems Fixed in Release 1.0.13
Table 7
PXM Software Bugs (continued)
Bug ID
Description
CSCds87891
Symptoms:
addcon screen help is not correct for the VCI range.
Conditions:
When addcon is issued.
Workaround:
None.
CSCds91053
Symptoms:
Observed following message on screen... call vsim_free_pdata.
Conditions:
When BXM is reset during lot of connection rerouting/derouting.
Workaround:
None.
CSCdt04611
Symptoms:
Copychan command used to build 1000 connections at a time appears to be causing
the ethernet interface to hang.
Conditions:
Ethernet chip appears to freeze. User loses connectivity to the switch.
Workaround:
Possibly a PXM switchover may resolve the ethernet connectivity issue.
CSCdt12510
Symptoms:
Intuitive error message appears when a connection is added on an existing endpoint.
Conditions:
When connection is added on an existing end point.
Workaround:
Do not add a connection on an existing end point.
CSCdt33174
Symptoms:
After formatting the PXM hard disk, the sysVersionSet command returns an error
about not being able to open C:/SHMDB/forced_version
Conditions:
2.0.12 code was used.
Workaround:
Before issuing the sysVersionSet command, create a /SHMDB directory and FTP the
four files from a working node's /SHMDB directory on to the node.
1.0.15 Software Release Notes for the SES Controller
30
October 19, 2001 78-11020-08
Problems Fixed in Release 1.0.13
Table 7
PXM Software Bugs (continued)
Bug ID
Description
CSCdt15090
Symptoms:
SES APS line reverts when it is configured for non-revertive mode.
Conditions:
When an APS line is set for bi-direction and non-revertive mode.
Workaround:
No work around.
CSCdt79361
Symptoms:
BPX clock source was not visible to SES.
Conditions:
When SES was attached to BPX.
Workaround:
Do not include the following commands in the list of PXM1 CLI commands:
CSCdt95688
•
cnfclksrc
•
delclksrc
•
dspclksrcs
Symptoms:
cnfsig returns syntax error.
Conditions:
Interface in provisioning state does not accept some values for t310.
Workaround:
Bring the port operationally up and then issue cnfsig with desired t310 values.
1.0.15 Software Release Notes for the SES Controller
October 19, 2001 78-11020-08
31
Problems Fixed in Release 1.0.12
Problems Fixed in Release 1.0.12
Table 8
Bug ID
Problems Fixed in 1.0.12
Description
S1 BUGS
CSCdt11833 Symptoms:
Standby controller card goes to failed state.
Conditions:
Upon performing loadrev after a clrcnf.
Workaround:
Do a setrev on slot 14(for Orion) or slot 32(for POPEYE2) with version number 0.0
CSCds65556 Symptoms:
The controller was out of memory and restarted.
Conditions:
Seems a rare scenario caused probably due to links repeatedly going up and down
resulting in deroute plus reroute of 50000 spvcs.
Workaround:
None.
CSCds73043 Symptoms:
Task suspends during its sync process.
Conditions:
Sending a single buffer to peer under ipcMblk resource contrain might cause an
exception since syncRam tries to access the memory which is taken by other task
already.
Workaround:
None.
S2 BUGS
CSCds82333 Symptoms:
Call is released on one node but does not get released on the peer.
Conditions:
Caused when lot of status enquiry happens when the nodes are highly congested. This
happens very rarely.
Workaround:
Clearing the connection manually.
CSCdt20186 Symptoms: Connection cannot be set up.
Conditions: When a Generic Identifier Transport IE of an invalid length (more than 33
bytes including the IE header) is received, the whole message is discarded. Therefore,
connection cannot be set up.
Workaround: Avoid sending Generic Identifier Transport IE of invalid length.
1.0.15 Software Release Notes for the SES Controller
32
October 19, 2001 78-11020-08
Problems Fixed in Release 1.0.12
Table 8
Bug ID
Problems Fixed in 1.0.12 (continued)
Description
CSCdt41939 Symptoms:
Connections as displayed by CWM are incomplete. Modifications on the connections
don’t show up on the CWM GUI. Connections exist on the switch and don’t show up
in CWM.
Conditions:
This can happen when there is a high volume of traps, for example when a script is
being run to delete a large volume of connections.
Workaround:
A configuration upload could be done to correctly synch the CWM with the switch
after the script has finished.
Another work around is, if a user needs to add/delete more than 1000 connections at
one time, he/she should pace the SPVC connections add/delete rate to avoid trap
overflow. The recommended rate is 1 conns/sec.
Further Problem Description: When there is a high volume of traps, especially on an
SES node, traps can be silently discarded by the switch after a burst of about 1000 traps
has been generated on a given card.
CSCdr50289 Symptoms:
XBAR plane available Multicast event buffer got corrupted.
Condition:
When XBAR plane available multicast is generated, which happens after standby
inserted.
Workaround:
None.
CSCds63497 Symptoms:
TLB exception on one of the ftp tasks.
Conditions:
Noticed only once - on a heavy loaded system. On the PXM card only.
Workaround:
If redundancy is enabled, conduct a switchover. On a standalone card, you would need
to reset the system. When the exception happens, one of the 4 ftp tasks on the pxm will
no longer be available to process requests.
CSCds89112 Symptoms:
SPVC connection failed to come up after power cycle.
Condition:
Slave connection has not been released while master still try to reestablish the call.
Workaround:
Do PXM switchover using switchcc
1.0.15 Software Release Notes for the SES Controller
October 19, 2001 78-11020-08
33
Problems Fixed in Release 1.0.12
Table 8
Bug ID
Problems Fixed in 1.0.12 (continued)
Description
CSCds07908 Symptoms:
lower E3 bank spvp’s in error after power cycle
Conditions:
shelf power cycle off/on
Workaround:
None
S3 BUGS
CSCds68731 Symptoms:
PXM card never goes active or standby. After a period of time, card is reset.
Condition:
PXM1 backcard is removed/not present. This can cause access to the disk to be slower
than usual. OPCONN task expects disk access to be complete in 1 minute. If not,
IPCONN task refuses to go active.
Workaround:
None if PXM1 backcard is required to be removed.
CSCds70657 Symptoms:
Last Fail Cause need to be more intuitive.
Condition:
SPVC was provisioned on an interface where correct SCT was not configured for the
interface.
Workaround:
None.
Close Comments: The DDTS is closed with the following reasons:
We cannot return a cause value other than the defined values in the UNI/PNNI spec. in
the RELEASE/RELEASE COMPLETE message. There are issues related to
UNI/PNNI conformance testing which prevents from sending proprietary/new cause
values.
1.0.15 Software Release Notes for the SES Controller
34
October 19, 2001 78-11020-08
Problems Fixed in Release 1.0.11
Problems Fixed in Release 1.0.11
Table 9
Bug ID
Problems Fixed in 1.0.11
Description
S1 BUGS
CSCds64807 Symptoms:
After you add the connections, then you change the number of LCNs in your partition,
if the number of the connections is more than LCN number, some of the connections
would be failed. If you reset the Service module, the connections failed routing may
be no deterministic. That is, before routed connection may be failed while some failed
connections may be successfully routed.
Conditions:
Workaround:
Do not change the LCN number below the provisioned SPVCs.
CSCds69959 Symptoms:
System reload due to pnCccb crash
Conditions:
dspconstats
Workaround:
None
CSCds84187 Symptoms:
After loadrev standby PXM keeps resetting
Conditions:
1.
Forced download was ON or Standby PXM did not have correct image file
2.
Running an old boot code that does not have a fix for CSCds85557
Workaround:
abortrev to bring up standby to old release.
Make sure forced download is OFF _ see CSCds72007
Use boot with fix for CSCds85557.
S2 BUGS
CSCdr64839 Symptoms:
Remove the TBC from the standby PXM's slot, then remove the active PXM, forcing
a switchover. Now, reinsert the TBC in the active (previously the standby) PXM's slot.
Conditions:
The TBC reinsertion event was not being reported to the SHM, causing incorrect
information to be displayed by commands such as dspcds.
Workaround:
None.
1.0.15 Software Release Notes for the SES Controller
October 19, 2001 78-11020-08
35
Problems Fixed in Release 1.0.11
Table 9
Bug ID
Problems Fixed in 1.0.11 (continued)
Description
CSCdr91876 Symptoms:
After a power cycle to the shelf.
Conditions:
Standby PXM1 card is stuck in Init state
Workaround:
Reset the standby PXM1 card
CSCds01154 Symptoms:
Sometimes some connections are in discontinuity state
Conditions:
Multiple PXM switchovers
Workaround:
Wait for resync to be over
CSCds04661 Symptoms:
Conns are in AIS
Conditions:
a.
resetcd (PXM or BXM)
b.
dnpnport/uppnport (PNNI trunk)
c.
rebooting via nodes
Workaround:
on PXM shellconn, issue following command:
vsim_debug_reset_slave_sesId (slaveIpc), where slaveIpc is the any valid BXM slot no
-1
CSCds07843 Symptoms:
This problem manifests itself only when a switchapsln CLI command is executed by
the user on the active front-card.
When the user issues a switchapsln command to either cause a (a) manual, or (b) forced
APS line switchover, the command returns without a feedback message to the user
whether the switch was completed successfully, or if it failed.
Conditions:
At present, the APS module doesn’t care about the actual result of the APS switchapsln
command. It assumes that the user will issue a subsequent dspapsln to verify the effect
of the APS switchover command previously issued.
Workaround:
In the absence of the output message from the switchapsln CLI command, the user
should issue a dspapsln CLI command to verify that the switchover command had the
desired effect.
1.0.15 Software Release Notes for the SES Controller
36
October 19, 2001 78-11020-08
Problems Fixed in Release 1.0.11
Table 9
Bug ID
Problems Fixed in 1.0.11 (continued)
Description
CSCds13879 Symptoms:
The port ends up in Building Vc state.
Conditions:
The port is brought up and down multiple times.
Workaround:
Bring the port down and up once.
CSCds14865 Symptoms:
Sometimes it takes approximately 2 hours to re-route 50K spvc connections.
Conditions:
The occurrence is very rare. It happens sometimes when switchover is done multiple
times
Workaround:
None.
CSCds17876 Symptoms:
The node allows SPVCs with VCI less than 32 to be added.
Conditions:
With the port's minsvccvci set to 32, attempts to add SPVCs with VCI less than 32 are
not rejected.
Workaround:
In order to properly use SPVCs with VCI values less than 35 (default), perform the
command before adding SPVCs with low VCI values.
cnfpnportrange <portid> -minsvccvci <desired minimal VCI value>
Since the VCI range below 32 is not recommended by ATM Forum and more control
VCs are reserved below VCI=35, a warning message listed below will be displayed
when the minSvccVci is changed to be below 35:
Note
MinSvccVci HAS BEEN ASSIGNED A VALUE LESS THAN
35.
CSCds18228 Symptoms:
If a connection fails to route in its first attempt, the subsequent reroute will be only
after 5 seconds. This constant cannot be modified by cli.
Conditions:
A single connection, upon a failure to reroute the first time may take 5-6 seconds to
reroute.
WorkAround:
None
1.0.15 Software Release Notes for the SES Controller
October 19, 2001 78-11020-08
37
Problems Fixed in Release 1.0.11
Table 9
Bug ID
Problems Fixed in 1.0.11 (continued)
Description
CSCds18328 Symptoms:
The switch has changed the default value of SvccVci from 32 to 35. This has not been
reflected in the MIB variable cwspMinSvccVci in CISCO-WAN-SVC-MIB.my.
Conditions:
From the MIB, a user would assume the SvccVci value is 32, yet when the user tries
to configure SVC or SPVC, the switch only allow configuration for 35 and above.
Workaround:
The user can configure SVC or SPVC with VCI only from 35 or above if the user
decides to use the default value. The user can also do an snmp GET of this variable for
the interface.
CSCds25863 Symptoms:
delpnport deletes all SPVCs on it
Conditions:
When delpnport is issued on PXM
Workaround:
Don't issue delpnport when there is a SPVC on it
CSCds36438 Symptoms:
Standby card does not come up after a restoreallcnf.
Conditions:
The database for the standby card is corrupted.
Workaround:
Perform sysClrallcnf on the standby card.
CSCds47032 Symptoms:
SNMP subagent does not respond to requests.
Conditions:
This problem occurs only if the memory partition used by the SNMP subagent runs out
of memory. This was seen when many connections were being added and deleted from
a test system in the presence of a memory leak in connection add.
Workaround:
Switchover to standby card
CSCds56895 Symptoms:
Some ports with ILMI on will be stuck in autocfg state.
Conditions:
Power cycle the ses and bpx.
WorkAround:
Bring the port down & up administratively and the port will be up.
1.0.15 Software Release Notes for the SES Controller
38
October 19, 2001 78-11020-08
Problems Fixed in Release 1.0.11
Table 9
Bug ID
Problems Fixed in 1.0.11 (continued)
Description
CSCds57013 Symptoms:
Dsplog command will show an entry for memory allocation fail. And this is usually
logged by an SNMP process (snmpMA, snmpMgmt, for example). The system may
switch side when this happens.
Conditions:
When adding connections on SES, there is a memory leak in SNMP subagent.
Workaround:
User can add connections from CLI. There is no workaround for user using snmp to
add connections at this time.
CSCds59748 Symptoms:
dspcons does not have an option for a bit failure connections
Conditions:
dspcons
Workaround:
None
CSCds60816 Symptoms:
After resetsys, previous Standby card becomes Active
Conditions:
After executing the resetsys command
Workaround:
None
CSCds61996 Symptoms:
Dsplog command will have an entry for memory allocation fail. And this is usually
logged by an SNMP process (snmpMA, snmpMgmt, for example). The system may
switch side when this happens.
Conditions:
When deleting connections on SES, there is a memory leak in SNMP subagent.
Workaround: User can delete connections from CLI.
Workaround:
None.
1.0.15 Software Release Notes for the SES Controller
October 19, 2001 78-11020-08
39
Problems Fixed in Release 1.0.11
Table 9
Bug ID
Problems Fixed in 1.0.11 (continued)
Description
CSCds63933 Symptoms:
When T301 timer times out, the PXM displays the explanation for the cause code as
invalid.
. > cause code - cause = (0x13)Invalid, IE_cause = (0x13)Invalid, location =
Private Network.
Conditions:
This occurs only when user has dbgsig turned on while the T301 timer expires The
PXM should display: (0x13)no answer from user (user alerted).
Workaround:
The problem only occurs when user has dbgsig turned on.
CSCds65708 Symptoms:
SVPCs calls are retried with same VPI on PNNI links after crankback due to VPI not
being available.
Conditions:
During SVPC connection routing/derouting
Workaround:
None
CSCds72034 Symptoms:
SPVC conns are in AIS
Conditions:
Pull out and pull in of UNI port
Workaround:
Down and up the UNI port using dnpnport and uppnport cmd on PXM
CSCds79424 Symptoms:
Port stuck in building-vc.
Conditions:
A card is pulled out and put back-in.
Workaround:
Use one of the following options:
1.
Down the port and up it again
2.
Pull out the card and put it back-in.
CSCds82333 Symptoms:
Call is released on one node but does not get released on the peer.
Condition:
Caused when lot of status enquiry happens when the nodes are highly congested. This
happens very rarely.
Workaround:
Clearing the connection manually.
1.0.15 Software Release Notes for the SES Controller
40
October 19, 2001 78-11020-08
Problems Fixed in Release 1.0.11
Table 9
Bug ID
Problems Fixed in 1.0.11 (continued)
Description
S3 BUGS
CSCdr52821 Symptoms:
Given a redundant SES with the PXM in slot 1 active and PXM in slot 2 standby. Have
ports provisioned with connections on them. Remove TBC from slot 2. Next, remove
the active PXM from slot 1, causing a PXM switchover. Now, reinsert the TBC in
slot 2.
Condition:
Once the PXM in slot 2 has taken over as the active PXM, the ports stay in the
Undefined state.
Workaround:
None.
CSCdr63291 Symptoms:
While converting PVCs with maximum traffic parameters through CWM conn_proxy,
conversion fails frequently for nrt-vbr1, vbr2, vbr3, cbr1 subtypes.
Conditions:
This problem is not reproducible.
Workaround:
None.
CSCdr87238 Symptoms:
The addpnni-node command has confusing syntax. The syntax says lowest ---if true,
the pnni node is set to the lowest level. But when entered true in the command it gives
error. The actual thing to enter is lowest. This was modified in the syntax help.
WorkAround:
None
CSCdr95869 Symptoms:
Programming the new Novram fails.
Condition:
The new Novram(AT93C66) required a different programming sequence.
Workaround:
None.
CSCds08804 Symptoms:
Cannot change minbw to a value greater than some value (which can vary from port to
port) using cnfpnportcac.
Conditions:
None
Workaround:
None
1.0.15 Software Release Notes for the SES Controller
October 19, 2001 78-11020-08
41
Problems Fixed in Release 1.0.11
Table 9
Bug ID
Problems Fixed in 1.0.11 (continued)
Description
CSCds10860 Symptoms:
dsppnni-ptse with -detail option was not displaying the complete information.
Condition:
When, user selects -detail option true, ptse print function was not calling CLI next
adopter.
Workaround:
In ptse print function modified the return code to allow the print function to print all
the information
CSCds11973 Symptoms:
dsppnportrsrc displays different portrsrc information on Active and Standby.
Conditions:
Change in rsrc information in switch is not updated to Redman.
Workaround:
Added warning when command is executed on standby Warning: Resource values are
not in sync with the active and may not be valid
CSCds12952 Symptoms:
Calls are released on the active card but not on the standby PXM.
Conditions:
Delete of a port goes to the standby card before bulk release calls does.
Workaround:
None.
CSCds23132 Symptoms:
Incoming SNMP requests generate the following error on the console:
Illegal call: getSnmpPduHeaderInfo unsupported in the PXM1 version of POPEYE2.1
Conditions:
PXM1 systems using Release 2.1 of the Cisco MGX88 50 firmware
Workaround:
None.
CSCds26236 Symptoms:
Controller type DC-8-T3E3 that support for PXM-1 had the same id as DC-8_T3E3
that support for AXSM-1. Conditions: Same controller type for the DC-8-t3E3 was
using for different target.
Workaround:
None.
1.0.15 Software Release Notes for the SES Controller
42
October 19, 2001 78-11020-08
Problems Fixed in Release 1.0.11
Table 9
Bug ID
Problems Fixed in 1.0.11 (continued)
Description
CSCds32434 Symptoms:
When a SPVC is call is established it's corresponding FAIL causes also will be
recorded if there is any. So if a SPVC call goes through without any problems then the
corresponding FAIL cause should be as No Fail
Condition:
After establishing the call execute dspcon to see the status of the call and see the Fail
cause if there is any. If the call goes through without errors the Last Fail cause field
was showing as SPVC Established which is not appropriate. So on request from
COVAD the Last Fail cause for a call with no errors was changed to No Fail.
Workaround:
None
CSCds49105 Symptoms:
Taking the standby PXM from one node and placing into the standby of another node
can cause the LAN interface of the old node to become disabled.
Conditions:
On a node with redundant PXMs, the boot IP and disk IP addresses for the LAN are
the same.
Workaround:
Pull ethernet cable when switching cards between nodes.
CSCds54170 Symptoms:
SETUP with incorrectly coded Called/Calling Party Number IE is allowed.
Condition:
This occurs when the Called/Calling Party Number is an AESA less than 20 octets in
length. It should be treated as IE with invalid content.
Workaround:
The problem will occur only if the Called/Calling Party Number is an AESA less than
20 octets in length.
CSCds56244 Symptoms:
The cause code in the Release message will not carry QOS unavailable when the end
to end CDV or CTD fails.
Conditions:
Whenever a call is initiated with an end to end CTD or CDV value which cannot be
supported on the node, the routing failure cause code will be only Destination
Unreachable.
Workaround:
None.
1.0.15 Software Release Notes for the SES Controller
October 19, 2001 78-11020-08
43
Problems Fixed in Release 1.0.11
Table 9
Bug ID
Problems Fixed in 1.0.11 (continued)
Description
CSCds62587 Symptoms:
When user executes tstdelay no information displayed on console.
Condition:
When no error in command syntax
Workaround:
Added display message to display Test started; Use dspcon to see test results when user
executes tstdelay or tstconseg
CSCds63506 Symptoms:
No defect will be exposed to user.
Workaround:
None
CSCds65459 Symptoms:
Ambiguous err code of network busy during connection provisioning
Conditions:
When provision an SPVC for a master endpoint where slave endpoint is already busy
with another master endpoint.
Workaround:
None
CSCds68717 Symptoms:
The MIB table 'cwspCacConfig' cannot be accessed.
Conditions:
The reason this table cannot be accessed is because an enum structure change was not
reflected in agent.
Workaround:
User can examine Cac parameters from CLI. There is no workaround for user using
snmp to access this table at this time.
1.0.15 Software Release Notes for the SES Controller
44
October 19, 2001 78-11020-08
Problems Fixed in Release 1.0.10
Problems Fixed in Release 1.0.10
Table 10
Problems Fixed in Release 1.0.10
Bug ID
Description
S1 BUGS
CSCdr76366
Symptoms:
SNMP GET on mib variable cwaChanOperStatus returns OK even the
connection is in FAIL state.
Conditions:
The reason for this bug is that when Conn Oper Status is determined, only the
connection state is checked but not the state of the interface. So when SNMP
gets retrieving this variable, it returns a wrong value.
Workaround:
None.
CSCdr76372
Symptoms:
Traffic does not pass with few connections.
Conditions:
1.
resetcd BXM
2.
burning BXM fw
Workaround:
On PXM shellconn, issue following command:
vsim_debug_reset_slave_sesId (slaveIpc), where slaveIpc is the any
valid BXM slot no - 1
CSCdr80672
Symptoms:
Port may stay in down in progress due to nodal congestion and nodal
congestion is always on.
Conditions:
Some failed testing or too much svc traffic. But this occurrence is very rare
Workaround:
None
CSCdr83226
Symptoms:
The node will perform system reload.
Conditions:
When delete partition on BPX for BXM ports.
Workaround:
None.
1.0.15 Software Release Notes for the SES Controller
October 19, 2001 78-11020-08
45
Problems Fixed in Release 1.0.10
Table 10
Problems Fixed in Release 1.0.10 (continued)
Bug ID
Description
CSCds06087
Symptoms:
The problem is an unexpected system reload.
Conditions:
When a crankback occurs due to AVCR not available, the source node
processing this crankback will have this problem.
Workaround:
None
CSCds09752
Symptoms:
The problem is an unexpected system reload.
Conditions:
When a load info from the service module is received and it is processed, such
load info processing will have this problem.
Workaround:
None.
CSCds09897
Symptoms:
The problem is an unexpected system reload.
Conditions:
Under rare conditions, when a crankback occurs due to AVCR not available
and when the node is also not reachable, the system will have this problem.
Workaround:
None
CSCdp93160
Symptoms:
When errors are injected on the working line, the working line status changes
from OK to an alarm state (depending on the bit-error rate, the state could be
SigF, ALM or some other state). The protection line should still be OK and
APS should switch to the protection line.
If CSCdp93160 (this bug) happens, the errors injected on the working line also
show up on the protection line, causing its status to change from OK to one of
SigF, ALM or other similar alarm states. Therefore, the APS sub-system
(wrongly) thinks that both lines are in error and switches back and forth
between the two as and when it finds the protection line toggling between OK
and alarm states. Due to this, traffic may be impacted.
Conditions:
Unknown.
Workaround:
None.
1.0.15 Software Release Notes for the SES Controller
46
October 19, 2001 78-11020-08
Problems Fixed in Release 1.0.10
Table 10
Problems Fixed in Release 1.0.10 (continued)
Bug ID
Description
S2 BUGS
CSCdu22689
Symptoms:
When the addshelf command was administered, a communication failure error
message appeared, and the user could not add the shelf.
Conditions:
The node name was the same for both the BPX and the SES.
Workaround:
The SES node name must be different from the node name of the attached BPX.
CSCdr47657
Symptoms:
Rarely some SPVC connections can not be added back after deletion.
Conditions:
Delete large SPVE connection and re-add same set of connections.
Workaround:
None.
CSCdr51004
Symptoms:
The CLI prompt takes some time to appear after entering q to quit from the
display commands.
Conditions:
It is seen for commands like dsppnports, dsppncons, dsppnni-path and other
commands involving multiple pages of output.
Workaround:
None.
CSCdr54204
Symptoms:
Calls will not get routed through the nodes in the network.
Conditions:
Some calls will not get rerouted problem.
Workaround:
None.
CSCdr62399
Symptoms:
When a PNNI command is executed when the cli is displaying the prompt
indicating that the cli is in the init state, it can cause the cli command task for
that session to get a task exception.
Conditions:
When the cli is displaying the prompt with a .i (for example:
hostname.7.pxm.i>) it means that the system is still booting up. Some
commands are currently not blocked in this state.
Workaround:
Do not issue configuration commands until the cli issues the prompt:
hostname.7.pxm.a>
1.0.15 Software Release Notes for the SES Controller
October 19, 2001 78-11020-08
47
Problems Fixed in Release 1.0.10
Table 10
Problems Fixed in Release 1.0.10 (continued)
Bug ID
Description
CSCdr63937
Symptoms:
redCoveringSlot field in the PXM redundancy MIB is not 0, when the primary
slot is Active.
Conditions:
When the primary slot is Active, PXM redundancy MIB does not give the
correct.
redCoveringSlot.
Workaround:
None.
CSCdr68627
Symptoms:
Port/ports on a node stays in building VC.
Conditions:
The problem occurs once when BXM and PXM software are upgraded
simultaneously.
Workaround:
Reload the BXM card(s), which is having the port(s) stuck in building VC.
CSCdr68691
Symptoms:
Spvc calls does not try to re-route
Conditions:
This problem may not be easy to reproduce, but a configuration of two or more
switches with SPVC’s and resetting the BXM cards while there were lots of
connections may cause it to happen.
Workaround:
None
1.0.15 Software Release Notes for the SES Controller
48
October 19, 2001 78-11020-08
Problems Fixed in Release 1.0.10
Table 10
Problems Fixed in Release 1.0.10 (continued)
Bug ID
Description
CSCdr70711
Symptoms:
Interfaces remain in Down State though interface is physically up and ILMI on
the interface is also up.
Conditions:
This has been observed only once and happened when BPX-SES was
undergoing overnight script based testing. As part of the test, the following
sequence of operations were being performed continuously:
1.
Down all ports.
2.
Wait for 5 minutes.
3.
Perform PXM switchover.
4.
Wait fro 5 minutes.
5.
Up all ports.
6.
Wait for 30 minutes.
7.
Perform PXM switchover.
8.
Repeat the above sequence 1 -7.
Workaround:
None
CSCdr74666
Symptoms:
RTM Proxy software module in CWM (Cisco Wan Manager) misses traps from
the switch
Conditions:
RTM Proxy in CWM tries to Upload traps (snmp mib walk) from the Upload
table. Sometimes, the trap in question is not available in the switch.This is
happening in a normal case (where there are not too many traps being sent from
the switch).
Workaround:
None.
CSCdr76381
Symptoms:
The user may notice that a connection shows FAIL on CWM GUI while the
same connection showed DOWN state on CLI.
Conditions:
When dncon is executed from CLI, the switch will send a
cwaChanDown(60307) trap followed by a cwaChanFail(60304). On CWM
side, the CONN FAIL state overwrites CONN DOWN states in its database.
However executing dspcon of the same connection, the same connection will
have DOWN state.
Workaround:
None.
1.0.15 Software Release Notes for the SES Controller
October 19, 2001 78-11020-08
49
Problems Fixed in Release 1.0.10
Table 10
Problems Fixed in Release 1.0.10 (continued)
Bug ID
Description
CSCdr78847
Symptoms:
The system stopped routing and stayed in congestion.
Conditions:
When the slave don’t have enough resources for all the connections or slave
failed.
Workaround:
Change the slave configuration and give enough resource. Then, switch-over.
CSCdr79020
Symptoms:
Subnetmask field is modified when modifying the Netmask attribute.
Conditions:
After using ipifconfig to configure the IP and Netmask, the user entered
dspipif to view it. The subnetmask field was modified instead of the Netmask
attribute.
Workaround:
Do not use NET_MASK unless you want to build a complicated SNMP
network by using subnet.
CSCdr82247
Symptoms:
DAX SPVCs will remain in Fail state.
Conditions:
This condition will happen when there is a large number of DAX connections
and the PXM or BCC is switched to the redundant cards or if the BXM is
rebooted or if the BXM cards are pulled out and plugged back in.
Workaround:
None.
1.0.15 Software Release Notes for the SES Controller
50
October 19, 2001 78-11020-08
Problems Fixed in Release 1.0.01
Problems Fixed in Release 1.0.01
Table 11
Bug ID
Problems Fixed in Release 1.0.01
Description
S1 BUGS
CSCdr28772 Symptoms:
Some pnni ports with ILMI on go down temporarily and come up. The calls are
de-routed and re-routed back.
Conditions:
This happens on a large network which has 50k spvc endpoints. The node has at least
14 trunks spread across 6 BXM cards. Pull out one of the cards and re-insert the card.
Workaround:
None.
CSCdr40383 Symptoms:
The exception log from crash is lost from dsperr after system reset.
Conditions:
Task monitor automatically resets a card when it crashes.
Workaround:
None.
CSCdr45402 Symptoms:
In some rare situation, vsi congestion bit was set. This resulted in the number of
connections fail to route.
Conditions:
Unknown.
Workaround:
None.
CSCdr45891 Symptoms:
1K call drop after unplugging the active PXM card.
Conditions:
The connection pending counter was 1532 (threshold is 500). This was due to message
drops on the SIGAPI Epid.
Workaround:
None.
1.0.15 Software Release Notes for the SES Controller
October 19, 2001 78-11020-08
51
Problems Fixed in Release 1.0.01
Table 11
Bug ID
Problems Fixed in Release 1.0.01 (continued)
Description
CSCdr46104 Symptoms:
Exception in pnCcb task causing the active processor to
reset.
Conditions:
Observed on de-routing and re-routing SPVCs over an IISP link.
Workaround:
None.
CSCdr46257 Symptoms:
SPVCs are getting re-routed on different NNI ports. They are released and then gets
routed on different port.
Conditions:
If we do many ( >4) consecutive switchovers then sometime this happens.
WorkAround:
Please avoid doing more than 3-4 consecutive switchovers or overnight switchovers.
S2 BUGS
CSCdr42002 Symptoms:
If the lkup command is left at the prompt Type <CR> to continue, Q<CR> to stop:
when the session times out or if ctl-C is hit when the lookup command is at this prompt
then the terminal port may become locked and unusable.
Conditions:
Unknown
Workaround:
Do not leave the CLI session idle while executing lkup and do not use ctl-C to exit
from a lkup command. No other known workarounds.
CSCdr43767 Symptoms:
Crash of Trap Server task (trapSvrTask) on the SES-PXM.
Conditions:
This problem occurs when there are more the 10K SPVCs setup and the BXM is
unplugged. The problem is intermittent.
Workaround:
Do not unplug the BXM cards during operation.
CSCdr45917 Symptoms:
In some rare situation, SPVCs connections are getting dropped. This resulted in the
number of connections do not match at nodes and specifically at both ends of the links.
Conditions:
Unknown.
WorkAround:
None.
1.0.15 Software Release Notes for the SES Controller
52
October 19, 2001 78-11020-08
Problems Fixed in Release 1.0.01
Table 11
Bug ID
Problems Fixed in Release 1.0.01 (continued)
Description
CSCdr46108 Symptoms:
Node stopped responding on quitting dspnni-ptse. The CLI was unavailable for typing
any further commands.
Conditions:
This one time occurrence was on a PNNI node attached to a RADCOM simulator that
simulates around 100 PNNI nodes and links. The node had 5 IISP links.
Workaround:
None.
CSCdr47016 Symptoms:
Some spvc connections can not be added back after deletion
Conditions:
Delete large spvc connection and re add same set of connections
Workaround:
None
CSCdr47505 Symptoms:
After repeated switchovers, few connections may re-route along other links. The
connections and the link do recover. This is because SSCOP on a link with connections
routed on it may go to Reset state temporarily and come back up.
Conditions:
Repeated switchovers at around one per 30 minutes.
WorkAround:
None
CSCdr47720 Symptoms:
SPVC_ERROR receiveReleaseComplete: null svc or softVcInfo
seen in system error log.
Conditions:
Observed while derouting and rerouting SPVCs over IISP links by downing and upping
IISP links.
Workaround:
None
CSCdr47782 Symptoms:
Standby PXM reloads
Conditions:
When there is too much traffic going on to standby from Active, sometimes connection
path gets congested and it may take more than 5 sec.
WorkAround:
None
1.0.15 Software Release Notes for the SES Controller
October 19, 2001 78-11020-08
53
Problems Fixed in Release 1.0.01
Table 11
Bug ID
Problems Fixed in Release 1.0.01 (continued)
Description
CSCdr47903 Symptoms:
Runtime image corrupted when FTPing; PXM pair has some boot IPaddr.
Conditions:
Unknown.
Workaround:
None.
CSCdr47937 Symptoms:
CWM shows connection as OK after upload.
Conditions:
After doing an upload.
Workaround:
Query for chan state.
CSCdr47997 Symptoms:
Task tDbgOutTsk is suspended after down and up PNNI link many time.
Conditions:
Unknown.
Workaround:
None.
CSCdr48012 Symptoms:
System switchover after cannot access shell mode for a while.
Conditions:
Unknown.
Workaround:
None.
CSCdr48230 Symptoms:
Trunk port goes into building VC when cnfrsrc is done.
Conditions:
Unknown.
Workaround:
None.
CSCdr48427 Symptoms:
PNNI trunk in ILMI Query after burning FW.
Conditions:
Unknown.
Workaround:
None.
1.0.15 Software Release Notes for the SES Controller
54
October 19, 2001 78-11020-08
Additional Deliverables
Table 11
Bug ID
Problems Fixed in Release 1.0.01 (continued)
Description
CSCdr48563 Symptoms:
Ports in Provisioning state with active calls.
Conditions:
Congestion caused by faulty feeder trunk. This is a very infrequent.
Workaround:
None.
CSCdr48832 Symptoms:
PNNI database took too long to update after down/up link (SLT).
Conditions:
Unknown
Workaround:
None.
Additional Deliverables
SNMP MIB
The SES controller MIB is being provided with the delivery of Release 1.0.00 of the SES controller
software on CCO. The MIB is in standard ASN.1 format and is included in the same directory where the
SES controller software is located within CCO. The SNMP SES controller MIB file can be compiled
with most standards-based MIB compilers.
Refer to Appendix E, SNMP Management Information Base, in the Cisco SES PNNI Controller Software
Configuration Guide, Release 1.0.01 for a description of the MIBs supported by the SES controller.
Default Values
There have been no changes.
1.0.15 Software Release Notes for the SES Controller
October 19, 2001 78-11020-08
55
BXM Firmware MFM Release Notes
BXM Firmware MFM Release Notes
About the Firmware MFM
BXM Firmware version M.F.M. supports all the existing interfaces and models of BXM hardware.
Following table outlines various levels of hardware revisions supported for BXM firmware version
M.F.M.
Table 12
Front Cards
Model Num
FW
model
Description
HW Rev
FW
Rev
BXM-155-4
4 port OC3 Line Module (Front Card)
F
B
MFM
MFM
BXM-155-8
8 port OC3 Line Module (Front Card)
F
B
MFM
BXM-622
1 port OC12 Line Module (Front Card)
F
D
MFM
BXM-622-2
2 port OC12 Line Module (Front Card)
F
D
MFM
BXM-T3-8
8 port T3 Line Module (Front Card)
F
B
MFM
BXM-T3-12
12 port T3 Line Module (Front Card)
F
B
MFM
BXM-E3-8
8 port E3 Line Module (Front Card)
F
B
MFM
BXM-E3-12
12 port E3 Line Module (Front Card)
F
B
MFM
BXM-155-8DX
8 port OC3 Line Module (Front Card)
F
A0
MFM
BXM-155-8D
8 port OC3 Line Module (Front Card)
F
A0
MFM
BXM-155-4DX
4 port OC3 Line Module (Front Card)
F
A0
MFM
BXM-155-4D
4 port OC3 Line Module (Front Card)
F
A0
MFM
BXM-622-2DX
2 port OC12 Line Module (Front Card)
F
A0
MFM
BXM-622-2D
2 port OC12 Line Module (Front Card)
F
A0
MFM
BXM-622-DX
1 port OC12 Line Module (Front Card)
F
A0
MFM
BXM-T3-12EX
12 port T3 Line Module (Front Card)
F
A0
MFM
BXM-T3-12E
12 port T3 Line Module (Front Card)
F
A0
MFM
BXM-T3-8E
8 port T3 Line Module (Front Card)
F
A0
MFM
BXM-E3-12EX
12 port E3 Line Module (Front Card)
F
A0
MFM
BXM-E3-12E
12 port E3 Line Module (Front Card)
F
A0
MFM
BXM-E3-8E
8 port E3 Line Module (Front Card)
F
A0
MFM
BXM-155-4
4 port OC3 Line Module (Front Card)
F
C
MFM
BXM-155-8
8 port OC3 Line Module (Front Card)
F
C
MFM
BXM-622
1 port OC12 Line Module (Front Card)
F
E
MFM
BXM-622-2
2 port OC12 Line Module (Front Card)
F
E
MFM
BXM-155-8DX
8 port OC3 Line Module (Front Card)
F
A0
MFM
BXM-155-8D
8 port OC3 Line Module (Front Card)
F
A0
MFM
1.0.15 Software Release Notes for the SES Controller
56
October 19, 2001 78-11020-08
New Features supported in BXM Firmware MFM
Table 12
Front Cards (continued)
Model Num
FW
model
Description
HW Rev
FW
Rev
BXM-155-4DX
4 port OC3 Line Module (Front Card)
F
A0
MFM
BXM-155-4D
4 port OC3 Line Module (Front Card)
F
A0
MFM
BXM-622-2DX
2 port OC12 Line Module (Front Card)
F
A0
MFM
BXM-622-2D
2 port OC12 Line Module (Front Card)
F
A0
MFM
BXM-622-DX
1 port OC12 Line Module (Front Card)
F
A0
MFM
Table 13
Back Cards
Model Num
Description
HW Rev
FW Rev
MMF-155-4
4 port multi-mode fiber back card
A
na
MMF-155-8
8 port multi-mode fiber back card
A
na
SMF-155-4
4 port single-mode fiber intermediate-reach back card
A
na
SMF-155-8
8 port single-mode fiber intermediate-reach back card
A
na
SMFMR-155-4
4 port single-mode fiber long-reach back card
A
na
SMFMR-155-8
4 port single-mode fiber long-reach back card
A
na
SMF-622
1 port intermediate-reach OC12 back card
A
na
SMF-622-2
2 port intermediate-reach OC12 back card
A
na
SMFMR-622
1 port long-reach OC12 back card
A
na
SMFMR-622-2
2 port long-reach OC12 back card
A
na
XLR-622
1 port extra long-reach OC12 back card
A
na
XLR-622-2
2 port extra long-reach OC12 back card
A
na
BPX-T3/E3-12
12 port T3/E3 back card
A
na
BPX-T3/E3-8
8 port T3/E3 back card
A
na
RDNT-LR-622-2
2 port long-reach OC12 redundant back card
A
na
RDNT-SM-622-2
2 port intermediate reach OC12 redundant back cards
A
na
RDNT-SM-622
1 port intermediate reach OC12 redundant back cards
A
na
RDNT-LR-155-8
8 port long-reach OC3 redundant back cards
A
na
RDNT-SM-155-4
4 port intermediate-reach OC3 redundant back cards
A
na
RDNT-SM-155-8
8 port intermediate-reach OC3 redundant back cards
A
na
New Features supported in BXM Firmware MFM
Bug fix only.
1.0.15 Software Release Notes for the SES Controller
October 19, 2001 78-11020-08
57
New Features supported in BXM Firmware MFK
New Features supported in BXM Firmware MFK
LCN cac with policing parameters set by PNNI controller. (Look at “Notes & Cautions” entry 10 for
warnings).
New Features supported in BXM Firmware MFJ
Bug fix only.
New Features supported in BXM Firmware MFH
1.
Dynamic partitioning feature is supported on the BXM card by default. Remote Shell Feature
through the BCC CLI provides a mechanism to turn off this feature.
2.
SPVC feeder support.
New Features supported in BXM Firmware MFF
Bug fix only
New Features supported in BXM Firmware MFE
Bug fix only
New Features supported in BXM Firmware MFD
Bug fix only
New Features supported in BXM Firmware MFC
1.
Support for SES (PNNI controller)
2.
BootCore enhancement to support multi-vendor flash-SIMMs
3.
1 msec granularity for tstdelay measurement.
1.0.15 Software Release Notes for the SES Controller
58
October 19, 2001 78-11020-08
New Features supported in BXM Firmware MFB
New Features supported in BXM Firmware MFB
1.
Multiple VSI (2.2) partition feature. Three partitions are supported
2.
Hitless Connection Density Upgrade for BXM
3.
SCR and PCR policing at less than 50 CPS for T3/E3 BXMs
4.
Control Traffic Shaping
New Features supported in BXM Firmware MFA
Multiple VSI (2.2) partition feature. (Two partitions)
New Features supported in BXM Firmware MEC
There is no new feature in release MEC
New Features supported in BXM Firmware MEB
There is no new feature in release MEB
New Features supported in BXM Firmware MEA
1.
VSI version 2.2 (single partition)
2.
ITUT Annex B and configurable Signal Degrade (SD) and Signal Failure (SF) thresholds for
SONET Linear APS on BXM-OC3 and BXM-OC12 (1+1, 2 card, 1:1).
The current default thresholds are as follows:
BIP count
Condition
10^-4
SF detected
10^-5
SD detected & SF clear
10^-6
SD clear & SF clear
New Features supported in BXM Firmware MDA
1.
Support for Virtual Trunking
2.
Support for BXM Multi-Level Channel Statistics
3.
SONET Linear APS on BXM-OC3 and BXM-OC12 (1+1, 2 card, 1:1)
4.
Support for card based LMI and ILMI
1.0.15 Software Release Notes for the SES Controller
October 19, 2001 78-11020-08
59
New Features supported in BXM Firmware MDA
Clarifications:
1.
The OC-3 MultiMode Fiber backcards do not support Y-cable redundancy.
2.
Upgrade from VSI 1.1 to VSI 2.2 is supported in this release. See upgrade section on page 9.
3.
APS 1:1 is not supported for VSI. (Bug CSCdp42996) APS 1:1 should not be configured on ports
intended to be used by PNNI or MPLS, as after switchover traffic flow is stalled on the protection
line for releases before MFE. However in MFE, this problem is fixed.
4.
Total BW allocated to all VSI partitions on a BXM should not be more that OC12 rate i.e., 1412832
cells/s. Currently BCC swsw allows uses to configure more than OC12 rate, in which case all the
PNNI connection commit requests would be NACKed by BXM
Special Installation/Upgrade Requirements
BXM cards with M.C.B/M.D.A firmware or later can be smoothly migrated to the M.F.A or above
version of firmware by using y-cable redundancy. To upgrade a BXM card pair in y-red configuration,
first upgrade the standby card with the MFA or above firmware version and wait for all the configuration
to be downloaded into the card. Do a switchyred to switch to the card with firmware M.F.A or above
version and burn the other card also with desired version MFA or above firmware. Follow the standard
firmware upgrade procedure for downloading and burning the firmware into the cards.
If BCC swsw version is 9.1.18 and dspnovram shows 0 or 4 for Number of Channel Stats it should be
OK to go directly to MFC or above versions directly from MCC.
Features obsoleted
1.
VSI 1.0 is obsoleted by VSI 2.2 in this release.
2.
Channel statistics level 0 is no longer supported for BXM-155-4, BXM-155-8, BXM-622,
BXM-622-2, BXM-T3-8, BXM-T3-12, BXM-E3-8, BXM-E3-12 models.
However it is still supported for all the other models (BXM-155-8DX, BXM-155-8D,
BXM-155-4DX, BXM-155-4D, BXM-622-2DX, BXM-622-2D, BXM-622-DX, BXM-T3-12EX,
BXM-T3-12E, BXM-T3-8E, BXM-E3-12EX, BXM-E3-12E, BXM-E3-8E)
Notes & Cautions
1.
2.
3.
BXM Model F firmware is intended for use with 9.3 switch software. BXM Model F firmware may
be used to upgrade BXMs during the upgrade process from switch software release 9.2 to 9.3. BXM
Model F firmware has not been tested for compatibility with release 8.4, 8.5, and 9.1 switch
software. It is compatible with IOS version 12.05t2 for MPLS.
M.F.E is a not on CCO, as it an orion specific release.
Burn firmware should not be interrupted. Card resets in the middle of burn firmware will result in
the BXM being maintained in the core state (Identified by blinking yellow LED), or failed state
(Identified by a solid red led). In this case the dspcds screen will report the card as FAILED. This
state can be recovered by reburning the firmware into the card.
1.0.15 Software Release Notes for the SES Controller
60
October 19, 2001 78-11020-08
New Features supported in BXM Firmware MDA
4.
Protection Switching based on BER on BXM may not comply to standards. The GR-253 & ITU-T
G.783 requires that switching be completed within 60 msec from the time the error starts. BXM is
unable to detect BER threshold crossing until the next poll, which occurs every 250 msec. Thus,
switching time may be up to 250 msec under certain circumstances.
5.
In APS 1+1 default configuration, both backcard LEDs show green when primary card is active and
selection is from PROT line. When primary card is active and it is selecting from PROT, PROT
backcard should be green, since it is carrying traffic. WORK backcard should also be green since
that is the physical path for the primary (and active) card to pass traffic. So backcard LED green
means the backcard is directly or indirectly carrying traffic and pulling the backcard will cause
traffic disruption. (CSCdm53430)
6.
In APS 1+1 default configuration and a manual W->P is on and a switchyred is issued, a manual
W->P event is logged. By default, on switchyred the new active card comes up in “clear” state. But
in this case since there is a manual W->P on, the APS line switches to PROT and the switching is
logged. (CSCdm53404)
7.
In APS 1+1 default configuration if the selected line is PROT and last user request is clear and a
switchyred is issued, line switches to WORK. If the last user request is “clear”, full automatic APS
switching is in effect with the working line being active by default. When there is no last user switch
request to switch to any particular line, the working line will become active. (CSCdm53420)
8.
When APS Annex B is added to local end which has the Secondary card active, the APS trunk goes
into Comm Failure for few seconds and then clears. If Secondary card is active, then do a switchyred
to make Primary card active and then add APS Annex B. (CSCdm46359).
9.
MFL supports LCN cac for class of services. Controller will reserve some LCNs for control VC as
default. These reserved LCN can not be used by any class of service any more in MFL. If all the
LCNs for the partition has been used in a version earlier than MFL, after MFL is updated in the
switch, some connections may not be added because they try to use LCNs reserved for control VC
which is not allowed. You need to configure more LCNs for the partition to make sure there is
enough LCNs for all the connections.
10. While upgrading from firmware, on OC3, 1 port OC12 BXM cards, if stats level on BXM is greater
than 1, the upgrade should take place according to the one of the following upgrade procedures:
– Upgrading from firmware revision MEA or higher
– Upgrading from firmware revision lower than MEA
1.0.15 Software Release Notes for the SES Controller
October 19, 2001 78-11020-08
61
New Features supported in BXM Firmware MDA
Upgrading from Firmware Revision MEA or Higher
Step 1
Step 2
SWSW should be upgraded to 9.2.30 or higher first,
Upgrade the firmware to MFL.
Upgrading from Firmware Revision Lower than MEA
Step 1
Firmware should be upgraded to MEC.
Step 2
Upgrade the swsw to 9.2.30 or higher revision.
Step 3
Upgrade the firmware to MFL to avoid the card mismatch.
Known Anomalies
The following is the list of known anomalies for the BXM firmware.
Table 14
Known Anomalies for the BXM Firmware
Bug ID
Description
Apply to SES
CSCdt36089
Symptom:
YES
BXMs on the via node do not detect AIS cells from AXSM.
Condition:
100K spvc routed through via node. Not all conns. at remote end see AIS
when failure occurs.
Workaround:
None
CSCdt32588
Symptom:
YES
Cells continuously get dropped when pumping traffic on spvcs.
Conditions:
Cells get corrupted when pumping traffic in SPVCs
Workaround:
no workaround
CSCdt29821
Symptom:
YES
Connections are in failed state
Conditions:
Stats was enabled when spvcs were added
Workaround:
Delete some SPVCs and then re-add them with stats disabled.
1.0.15 Software Release Notes for the SES Controller
62
October 19, 2001 78-11020-08
New Features supported in BXM Firmware MDA
Table 14
Known Anomalies for the BXM Firmware (continued)
CSCdt29475
YES
Symptom:
Egress QE dropping packets result in loss of connection.
Condition:
Ports were stuck in provisioning state while connections were routing.
Workaround:
None.
CSCdt27294
YES
Symptom:
After executing resetsys on the redundant pxm1 cards, the SES becomes
unreachable on the bpx.
Condition:
The Orion node (SES / BPX) has redundant pxm1 card and 96K spvc were
configured.
Workaround:
UNKNOWN.
CSCdt26321
Symptom: Card error 0xb0000005 causes BXM in failed state when the
YES
number of connections for one card goes to 31.6k.
Condition:
intermittent.
Workaround:
None.
CSCdt21547
YES
Symptom:
There is no command available to clear SPVC statistics on SES controller.
Condition:
Function not implemented.
Workaround:
None.
CSCdt13171
YES
Symptom:
After dellp, traffic is not right when VP connection and cnfln VC shaping
enabled.
Condition:
reproducible.
Workaround:
None.
1.0.15 Software Release Notes for the SES Controller
October 19, 2001 78-11020-08
63
New Features supported in BXM Firmware MDA
Table 14
Known Anomalies for the BXM Firmware (continued)
CSCdt21569
Symptom:
YES
CAC policy not downloaded to some BXM, causing connection fails or
building VC.
Conditions:
Intermittent
Workaround:
None.
CSCds78285
Symptom:
YES
CAC policy not downloaded to some BXM cards.
Condition:
Ports go into building VC state
Workaround:
None
CSCds16136
Symptom:
YES
Channel Mismatch appears as status even though LOS was still present.
Conditions:
In near succession, recovery of LOS on Working line and appearance of
LOS on Protection line.
Workaround:
No.
CSCds47753
Symptoms:
YES
Card error will happen in standby VrmDekConnEndPoint Try to delete
Condition:
When standby syncs up with active, it tries to delete a not existing
connection.
Workaround:
The card error indicates that there is a invalid try of deleting a non-existing
connection. It should not create any problem in existing or new connection.
Still this problem will be analyzed more.
CSCdr85398
Symptom: 2 nodes with 2 PNNI controllers cnfpnportrange command used to
YES
force a LOC, missing COA point trap dnpnport/uppnport, restarting ILMI
session, results in COA trap.
Conditions:
when ILMI session is first initialized, or restarted, if SysUpTime doesn’t
change, COA trap shouldn’t not be sent to controller. When an LOC is
detected by ILMI on BXM and it is followed by a “Loss of Attachment
Point” when connectivity is re-established, ILMI on slave does not give a
“Loss of Attachment Point” trap.
WorkAround:
None
1.0.15 Software Release Notes for the SES Controller
64
October 19, 2001 78-11020-08
New Features supported in BXM Firmware MDA
Table 14
Known Anomalies for the BXM Firmware (continued)
CSCdr06316
NO
Symptoms:
VPC connection drops cells over BXM trunks.
Condition:
reproducible.
Workaround:
None
CSCdr11810
NO
Symptoms:
BXM does not report Abit when SPVC feeder is provisioned without AR
feeder segment.
Conditions:
Reproducible.
Workaround:
None.
CSCdr45464
NO
Symptom:
0B card error are reported. on BXM-oc3 cards.
Condition:
When the cards in yred. Most probably a bad hardware.
Workaround:
No workaround.
CSCds01128
NO
Symptom:
LOS occurs sometimes on several trunks.
Conditions:
Unknown. According to the bug report, once in a while for a couple of
minutes.
Workaround:
recovers on it’s own.
CSCds21403
YES
Symptom:
After downing the NNI ports, ports went into provisioning state due to
running buffer leakage.
Condition:
Seen only once
Workaround:
Reset the card and continue, no known workaround
1.0.15 Software Release Notes for the SES Controller
October 19, 2001 78-11020-08
65
New Features supported in BXM Firmware MDA
Table 14
Known Anomalies for the BXM Firmware (continued)
CSCdr45566
NO
Symptom:
cnftrafficgen does not work correctly
Conditions:
Unsupported.
Workaround:
None
CSCds69832
NO
Symptoms:
0x52 message returns default value for the UBR connection.
Conditions:
UBR connection get command issued by BCC.
Workaround:
No work around
Table 15
Bugs Fixed in MFL
CSCds15145
Symptom:
Max BW could be configured as less than Min.
Condition:
This might happen as the policy parameter might not be checked for the
consistency.
Workaround:
Do not configure Max below min.
CSCds06835
Symptom:
Nodes become unreachable if CC traffic traverses to the destination node via
a UXM-BXM virtual trunk.
Conditions:
CC traffic is passed across virtual trunks.
Workaround:
Change the trunk configuration with cnftrk command to restrict CC traffic
on virtual trunks.
CSCds75221
Symptom:
When Issuing the command dspconstats for ABR or UBR connection it does
not report the CLP0 and CLP1 correctly.
Conditions:
Statistics for ABR and UBR not updated.
Workaround:
None
1.0.15 Software Release Notes for the SES Controller
66
October 19, 2001 78-11020-08
New Features supported in BXM Firmware MDA
Table 15
Bugs Fixed in MFL (continued)
CSCdt38554
Symptom:
After executing resetsys on the node(svcpop2) pxm1 cards. there
are two ports stuck in building vc.
Condition:
The node(svcpop2) has 100k routed spvc connections.
Workaround:
UNKNOWN
CSCdt45966
Symptom:
Checksum calculation is not correct in BXM.
Condition:
Connection conditioning via bulk set cmd.
Workaround:
Uppnport/dnpnport on UNI and NNI port and do switchyred to kick resync.
CSCdt48062
Symptom:
Port gets stuck in building VC state.
Condition:
Connection admission control.
Workaround:
Establish connections of various service type and bandwidth requirements.
Table 16
Bugs Fixed in MFK
CSCdt21322
Symptom:
BXM load info returned to controller is wrong when maxbw set to 0
Condition:
reproducible
Workaround:
None.
CSCdp16050
Symptom:
maxvc functionality for CAC not working
Conditions:
reproducible
workaround:
none.
1.0.15 Software Release Notes for the SES Controller
October 19, 2001 78-11020-08
67
New Features supported in BXM Firmware MDA
Table 16
Bugs Fixed in MFK (continued)
CSCdt04632
Symptoms:
For a vsi partition, the reporting available number of LCN is greater than the
maximum number of LCN configured for that partition.
Conditions:
When the port group unused LCN is less than the maximum LCN configured
for the partition and the unused LCN for the port group plus the LCN that
still left from the reserved (min-curr) is greater than the max of the partition.
Workaround:
None.
CSCds85653
Symptom:
BXM card error of cb_if.c 1588 CbCoreTxEvent(): Failed core_cbmsg_put:
return.
Condition:
Continually doing switchcc with large amounts of AR/SPVC connections
Workaround:
Reset BXM card
CSCds76142
Symptom:
BXM card shows standby-failed status
Condition:
Download firmware on standby card
Workaround:
Reset BXM card.
CSCds65105
Symptom:
When pumping the ATM CBR traffic at the rate over = of port line rate
(BXM-622), at the egress dspchstats shown the number of cells. From
Network’ twice larger than ‘To Port’.
Conditions:
DAX conn from BXM-622 port 1-2 on the same node with ADTECH
generate traffic.
Workaround:
None
CSCdr19696
Symptom:
user never gets to know when the line is out of SD/SF condition. both the aps
lines always show in OK state in dspapsln
Conditions:
APS Line switches to stby line because of SD/SF condition. dspapsln will
still show OK for both the lines. This way, user will never get to know when
this line has come out of SD/SF condition.
Workaround:
Use rsh command to get all the aps line’s status.
1.0.15 Software Release Notes for the SES Controller
68
October 19, 2001 78-11020-08
New Features supported in BXM Firmware MDA
Table 17
Bugs Fixed in MFJ
CSCds61912
Symptom:
After downloading new firmware(MF30), card in failed state.
Condition:
Downloading MF30 firmware release.
Workaround:
Don’t use MF30 which is a development release between MFH and MFJ.
CSCds11506
Symptom: Min guaranteed cell rate shows a cell less than configured.
Conditions: Setting min BW to say 3333334 and policy BW% to 5859
Workaround: Increase the minBW by few cells.
CSCdr19696
Symptom:
user never gets to know when the line is out of SD/SF condition. Both the
aps lines always show in OK state in dspapsln
Conditions:
APS Line switches to stby line because of SD/SF condition. dspapsln will
still show OK for both the lines. This way, user will never get to know when
this line has come out of SD/SF condition.
Workaround:
Use rsh command to get all the aps line’s status.
CSCds32845
Symptom:
Connection commits rejected with reason: “no resources even when
resources are actually available”.
Condition:
Enabling/disabling a virtual trunk.
Workaround:
Resetting the BXM after disabling a VT on any interface on the card.
1.0.15 Software Release Notes for the SES Controller
October 19, 2001 78-11020-08
69
New Features supported in BXM Firmware MDA
Table 17
Bugs Fixed in MFJ (continued)
CSCds37237
Symptom:
When upgrade BXM firmware image to BXMMFH from images between
BXMMFC-BXMMFF, if the network migration flag was enabled in a card
before the upgrading, then after burning the new image to the card, the
network migration flag becomes disabled mistakenly.
Condition:
The problem only happens to the card whose previous image is
BXMMFC-BXMMFF, and the network migration flag was enabled before
upgrading, and BXMMFH has to be the new image.
Workaround:
Upgrading to image BXMMFH+ (not including BXMMFH), will not have
any problem. network migration flag is always enabled, and no user
command available any more to disable it.
Only for the situation you need to upgrade image to BXMMFH and your
card’s previous images is BXMMFC-BXMMFF, you may see the problem.
Issue either the “rsh <slot> cdcfg netwotk dis” command before the
upgrading, or issue the “rsh <slot> cdcfg netwotk ena” command after the
upgrading, to enable the netwotk migration flag on BXMMFH.
CSCds59710
Symptom:
Loss of traffic on a VPC connection added with VPI=0
Conditions:
SWSW: 9.3.10
BXM FW: MFF
The port on which the VPC connection has been added has a VSI ctrlr
attached to it and the Ctrlr is usingVPI=0 and VCI=x for its signalling
channel.
Workaround:
If a VPC connection exists with VPI=0, on the port to which a Ctrlr is to be
added, configure the signalling channel on the controller side to use a VPI
other than 0.
CSCds63578
Symptom:
SW errors 105 logged on BXM while adding VSI connections. Subsequent
card errors saying CB_TASK restarted.
Condition:
This error sometimes happen when a VSI partition is enabled/disabled many
times.
Workaround:
Reset the BXM.
1.0.15 Software Release Notes for the SES Controller
70
October 19, 2001 78-11020-08
New Features supported in BXM Firmware MDA
Table 17
Bugs Fixed in MFJ (continued)
CSCds65105
Symptom:
When pumping the ATM CBR traffic at the rate over = of port line rate
(BXM-622), at the egress dspchstats shown the number of cells “From
Network” is twice as large than ‘To Port’.
Conditions:
DAX conn from BXM-622 port 1-2 on the same node with ADTECH
generate traffic.
Workaround:
None
CSCds67854
Symptom:
SPVC cannot be routed over the virtual trunk even when enough bandwidth
and lcn are available. Routed connections discard some traffic.
Condition:
Routing connections of different service types over the virtual trunks.
Workaround:
None.
CSCds04137
Symptom:
Channels remain mismatch after lockout is cleared
Conditions:
In ITU-T Annex B protocol for APS, when a condition causes a switch to
occur while a lockout request is present, the channel change will not
re-synchronize even after the lockout is cleared.
Workaround:
No
CSCds53645
Symptom:
ABR connections (PNNI) not programmed properly for redundant slave.
Condition:
Switchyred
When connection is added, redundant card is not there and inserted at later
stage.
When connection is added, no redundant config, addyred at later stage.
Workaround:
None
1.0.15 Software Release Notes for the SES Controller
October 19, 2001 78-11020-08
71
New Features supported in BXM Firmware MDA
Table 18
Bugs Fixed in MFH
CSCds14495
Symptom:
Dynamic Partitioning and SPVC AIS generation would not work on a card
until a rsh command is issued to enable the network migration flag and reset
the card.
Conditions:
When a card comes up and has never enabled the network migration flag for
life time. This network migration flag is used for enabling dynamic
partitioning and SPVC AIS, status report generations. By default, the flag is
disabled.
Workaround:
Use the “rsh <slot> cdcfg netmig en/dis” command to enable/disable the
flag, then reset the card once in a liftime.
Table 19
Bugs Fixed in MFF
CSCds08448
Symptom:
ERS (explicit rate stamping) is working only first virtual trunk and NOT for
subsequent VTs (standard ABR)
Condition:
When ERS is enabled on a card basis using “cnfabrparm”, the mapping is
done on a port-by-port basis. The port_vi is used but for virtual trunks, this
mapping does not hold true. Need to change the mapping to the physical
port.
Workaround:
On any physical port, just set up one virtual trunks. Or a physical trunk.
Multiple VTs on the same physical port will cause a problem
CSCdr79610
Symptom:
Change booking factor for a class of service, get rejected.
Condition:
When there are some connections established, and some of the class of
service have used bandwidth exceeding their reserved, change booking
factor for any class of the service may get rejected.
This is because it fails the check which should only be called when
cos_min_bw in
the policy parameters is changed. This check should not be called when
booking factor is changed.
Workaround:
Disable that partition, change the booking factor, then enable the partition
again. Or keep the used_bw for all cos under teh cos_min_bw, you will be
able to change booking factor freely.
1.0.15 Software Release Notes for the SES Controller
72
October 19, 2001 78-11020-08
New Features supported in BXM Firmware MDA
Table 19
Bugs Fixed in MFF (continued)
CSCdr76334
Symptom:
Connect OC3 port on BXM with 7200 router, connect 2 OC3 ports back to
back. enable ILMI on router, and ILMI, protocol on card cnfrsrc VSI part 1
disable NebDiscovery on ports.when running cnfnodeparm 56 0|1 and With
VSI disabled, peer info is transmitted to peer. delcntrl, and cnfrsrc deleting
VSI partition, fails to disable Peer information as well.
Condition:
ilmi_enable_from_contrl bit was not cleared when delctrlr, or vsi partition
deleted, thus vsi code kept issuing get requests and responding to peer
information.
in AR/VSI hybrid networks, and for backward compatibility either BXMs
w/o NebDisc, or swsw versions. Topo traps are not sent to downrev’d swsw
versions, and are controllable by sw software for versions including the
feature.
Code was added to properly support disabling of VSI functionality using
delctrlr or cnfrsrc at BCC in addition to existing dnpnport at the VSI
controller. support for backrev’d cards added, and corrections to logic in Ilmi
FSM state machine to properly send TopoTrap to BCC.
Workaround:
None
CSCdr79936
Symptom:
Stats files not generated/missing on some 15 minutes intervals.
Conditions:
When system time is changed at 15 minutes boundaries.
Workaround:
Minimize system time and card config changes.
CSCdr83144
Symptom:
Card error of:
N. Fatal from 0x17: 0x25120075 0x809b5f90 0x367e 0x1
Conditions:
switchyred, switchcc or reset PXM when there are spvc connections with
stats enabled.
Workaround:
None
CSCds11484
Symptom:
Available cell rate reported by BXM is incorrect.
Conditions:
Sum of the minimum bandwidths of all the interfaces on a BXM reaches
OC12.
Workaround:
Reduce minimum BW on all interfaces by half.
1.0.15 Software Release Notes for the SES Controller
October 19, 2001 78-11020-08
73
New Features supported in BXM Firmware MDA
Table 19
Bugs Fixed in MFF (continued)
CSCdr89217
Symptom:
Software Error Log of 9098
Conditions:
cnfrsrc of partition 3 using MEB firmware
Workaround:
None
CSCdr89966
Symptom:
Card Error of 0x41030006
Conditions:
PXM controller is upgraded/re-booted
Workaround:
None
CSCdp89085
Problem:
The total call count becomes negative on the BXM interface. However,
this problem has not been reproducible.
Symptoms:
If this problem happens, the following card error is displayed:
’vsi_rsrc_pfns.c 483 VrmRetLcnResources 3, 16316’
workaround:
A related bug CSCdr86894 which reported an incorrect number of total
call counts, has been found to be the result of an uninitialized variable in
vsi_rsrc_conn_pfns.c: VrmRsrcClrRCMP().
The debugging information embedded in this function may be helpful in
verifying the negative call count problem if it is reproduced.
1.0.15 Software Release Notes for the SES Controller
74
October 19, 2001 78-11020-08
New Features supported in BXM Firmware MDA
Table 20
Bugs Fixed in MFE
CSCdp05098
Symptom:
Cell discards occur for ABRFST/ABRSTD conns when the traffic burst is
greater than the MBS
Conditions:
This occurs when the traffic burst size is fixed to 140000 cells at 70000 cps.
The conn are configured with PCR=72000/72000, MBS=1000/1000 and ICR
7200/7200. This is the expected behavior since the configured MBS < the
actual burst size.
Workaround:
Increase the MBS and ICR using cnfcon.
CSCdr59731
Symptom:
port 11.1 is connected to 11.2 and ILMI are up and running on both ports.
Enable neighbor discovery on 11.1, then 11.2.
The 0x71 responses/traps from BXM fw is not predictable. At least two
variations are observed:
Variation 1. port 11.2 has it’s neighbor’s info but port 11.1 doesn’t.
Variation 2. both port 11.1 and 11.2 only know the IP addresses of their
neighbors. The Neighbor’s IFName are missing. Problem was observed in
MF17, but code changes in more recent builds had already repaired the
problem.
Conditions:
when ILMI session restarts, remnants of IfName, IpAddr from previous
session left. Clr/reset IfName,IpAddr in MIB, on ILMI session restart In
FMSStart, pIlmiProcessFsmStart() calls a new function
IlmiClrPeerAndSendTopoTrap(pcb_ptr->session_id)
Workaround:
None
CSCdr79936
Symptom:
Stats files not generated/missing on some 15 minutes intervals.
Conditions:
When system time is changed at 15 minutes boundaries.
Workaround:
Minimize system time and card config changes.
1.0.15 Software Release Notes for the SES Controller
October 19, 2001 78-11020-08
75
New Features supported in BXM Firmware MDA
Table 20
Bugs Fixed in MFE (continued)
CSCdm16800
Symptom:
Card error 0xc000007 appears in the card error log.
Conditions:
This error indicates that an unknown type of cell which is not expected has
arrived in the egress QE.
Workaround:
Engineering has done in-depth investigation into this case. We are convinced
the problem does not affect user traffic or the node in any other way.
Therefore, the symptom will not be reported as a card error. The fix has been
incorporated into MEE firmware.
CSCdp22930
Symptom:
N/A
Conditions:
cbus rd/wr operations set up in the PUUMBA chip when performing cbus
rcv/xmit.
Workaround:
None
CSCdp74680
Symptom:
Even if the interface is in LOS, the spvc’s do not generate ingress AIS into
the network.
Conditions:
Connection is added after the interface goes into LOS.
Workaround:
None
CSCdr44250
Symptom:
Private image did not allow as many OAM cells to flow as public image.
Conditions:
This occurred by undoing a hardware fix in a private image.
Workaround:
This was never introduced into the Public view and no workaround is
required.
CSCdr45986
Symptoms:
Standby and active block checksum value do not match and resync happens
on switchover.
Conditions:
When active card has many spvc connections derouted it happens.
Workaround:
None.
1.0.15 Software Release Notes for the SES Controller
76
October 19, 2001 78-11020-08
New Features supported in BXM Firmware MDA
Table 20
Bugs Fixed in MFE (continued)
CSCdr71473
Symptom:
Unreachable BXM, sw errors and cd errors on the BPX.
Conditions:
LMI is enabled when controller either slow to respond or un-reachable.
Workaround:
Disable LMI.
CSCdp97307
Symptoms:
When executed “rsh <slot> vsi cm VsiIs” without parameter. The card will
crash.
Conditions:
Always.
Workaround:
Pullout the card and reinsert.
CSCdr86894
Symptoms:
Many ports have VC failure because BXM has no resource to build the CVC.
Conditions:
intermittent
Workaround:
Reset BXM card.
CSCdr57712
Symptom:
Multi_partition fails to report all virtual trunks.
Condition:
In case of virtual trunks with different partition.
Workaround:
Reset the BXM card.
CSCdr77238
Symptom:
Switch General Info does not contain bulk set capability bit. With newer
images of PXM bulk set will not work with BXM images prior to MFD.
Condition:
PXM Images later than 07/06/2000 contains logic to identify the bulk set
capability of the slave. BXM images prior to 07/06/2000 will not have this
bit set because it is newly introduced parameter in VSI spec.
Workaround:
No Workaround. Need to upgrade to MFD.
1.0.15 Software Release Notes for the SES Controller
October 19, 2001 78-11020-08
77
New Features supported in BXM Firmware MDA
Table 21
Bugs Fixed in MFD
CSCdr29278
Symptom:
Originally the card used to get frozen not responding to any request from the
controller, as the TCB database was corrupted. But it has been protected
now. But whenever a null pointer is being inserted into the TCB list a card
error is being flagged. It is a harmless card error (not service affecting).
Conditions:
The cause is unknown.
Workaround:
none.
CSCdp63445
Symptom:
ABR and UBR connections loose traffic when VC shaping is turned on.
Conditions:
Enabling of VC shaping on port terminating ABR and UBR connections.
Workaround:
Leave VC shaping disabled.
CSCdr30454
Symptom:
Connections (LCNs) can not satisfied because of insufficient memory.
Condition:
When channel stat level is set to 0.
Workaround:
Use chan stat level (cnfcdparm) 1, 2 or 3.
CSCdr14247
Symptom:
The correct state of an SPVC is not reflected in connection bulk traps for
large number of connections (> 1000). Sometimes Connection states keep
toggling between AIS and CLR state when the conns are actually in AIS state
Conditions:
AIS cells generated by the RCMP on different connections arrive too close
to each other in the same second. This sudden burst of cells overwhelm the
Class of service buffers (QBINs) in the Egress direction and get discarded.
This causes remote end of the trunk to detect a loss of AIS cells and declare
connection a CLR.
Workaround:
None.
1.0.15 Software Release Notes for the SES Controller
78
October 19, 2001 78-11020-08
New Features supported in BXM Firmware MDA
Table 21
Bugs Fixed in MFD (continued)
CSCdr40204
Symptom:
Service rate for VBR traffic when WFQ is enabled is at SCR (instead of
PCR) even when there is no congestion for enhanced cards (1210 QE &
Sabre)
Condition:
For enhanced cards, when WFQ is enabled, the local congestion is monitored
at the Egress side by the hardware. In order to do this, a few variables that
need to be initialized. There were some problems with the initialization
routine, causing inaccurate tracking of the congestion level.
Workaround:
None. Has been fixed.
CSCdr42885
Symptom:
All the ports on a BXM slave go into provisioning state.
Condition:
Controller looses communication with the BXM. This happens when AAL5
driver in the BXM mal-functions and does not free the message buffers of
the application processes (ILMI/VSI etc). Eventually BXM runs out of
message buffers.
Workaround:
Reset the BXM card.
CSCdr49056
Symptom: Invalid Part id in SPVC stats after controller is added.
Condition:
This problem happens when SFM receives the vsi message before adding the
controller. This is possible to happen when there is a delay between 52 and
61 message. Since 52 add the control vc it will receive the frame and give it
SFM task. But SFM won’t have any information for that partition and will
report the error saying that invalid partition. Since this is possible to happen
as per design, the card is removed now.
CSCdr40234
Symptom:
Service rate for UBR traffic when WFQ is enabled much lower than PCR
even when there is no congestion for enhanced cards (1210 QE & Sabre)
Cause:
For enhanced cards, when WFQ is enabled, the local congestion is monitored
at the Egress side by the hardware. In order to do this, a few variables that
need to be initialized. There were some problems with the initialization
routine, causing inaccurate tracking of the congestion level.
Workaround:
None. Has been fixed.
1.0.15 Software Release Notes for the SES Controller
October 19, 2001 78-11020-08
79
New Features supported in BXM Firmware MDA
Table 21
Bugs Fixed in MFD (continued)
CSCdr49060
Symptom:
When doing a cnfcon for ABR connection, service rate drops to MCR rate
even when there is no congestion. This is when WFQ is enabled and the
inherent VSVD is not used.
Cause:
There are a certain parameters associated with WFQ that are required in
order for WFQ to work. However, for ABR connections, when a cnfcon is
done, once it is detected that VSVD is not enabled, the structure (Sabre rate
RAM) which holds all these parameters is cleared out. This would cause
WFQ not to operate properly.
Workaround:
No need. Fix is done.
CSCdr43012
Symptom:
All the ports on a BXM slave go into provisioning state.
Condition:
Controller looses communication with the BXM as AAL5 driver in BXM
gets stuck.
Workaround:
Reset the BXM card.
CSCdr52195
Symptom:
All the ports on a BXM slave go into provisioning state.
Condition:
Controller looses communication with the BXM as AAL5 driver in BXM
gets stuck.
Workaround:
Reset the BXM card.
1.0.15 Software Release Notes for the SES Controller
80
October 19, 2001 78-11020-08
New Features supported in BXM Firmware MDA
Table 21
Bugs Fixed in MFD (continued)
CSCdr36963
Symptom:
When PNNI controller goes down then comes up, it couldn’t establish its
control call to the BXM partition, thus VC failure is displayed in PNNI
controller for that partition.
Condition:
This problem only happens under the following conditions:
1.
The policy parameters for the partition have been configured as nonzero
at some of the class of service,i.e. the reserved minimum bandwidth of
some class of service are nonzero.
2.
Delete/disable that partition. BXM suppose to release all resources.
However, it only released resources at partition level, but leave the
reserved resources at cos level unchanged. As result, when this partition
is enabled again, the internal CAC calculation at partition level became
negative. That caused the first control call setup request fail.
Workaround:
Reset the BXM card will clear the VC failure.
CSCdr33867
Symptom:
Connect OC3 port on BXM with 7200 router, enable ILMI on router, and
ILMI, protocol on card and Neighbor Discover, Object 0x31, Peer’s IfName
is not null terminated.
Conditions:
Some peer.ifName’s are null terminated, some aren’t a PDU containing valid
nonzero length peer.ifName doesn’t always include’\0’; and is stored
accordingly in the MIB. added a test if peer.ifName is non-zero in length,
and isn’t null terminated, concatenate the’\0’char and bump
peer.ifNameLen++ count Added logic CbIlmiStatsReport, ilmi_proc.c
pIlmiFsmGetResponseEventAtS3, pIlmiFsmGetResponseEventAtS9,
ilmi_fsm_evt.c to ensure TopoTrap, and ILMIStats report are correctly
formated.
Workaround:
None.
CSCdp48306
Symptom:
on NNI side, when cross connect is established with VPI>1000 (0x3e8) the
first nibble is getting chopped off and traffic is flowing on VPI 0xe8 due to
bad programming of connection.
Conditions:
This happens if on NNI side VPI > 0xff.
Workaround:
None.
1.0.15 Software Release Notes for the SES Controller
October 19, 2001 78-11020-08
81
New Features supported in BXM Firmware MDA
Table 21
Bugs Fixed in MFD (continued)
CSCdr51875
Symptom:
Virtual Trunking causing Unreachability
Conditions:
•
At least Two virtual trunks share a common port at one node, but their
remote endpoints terminate on different nodes.
•
The virtual trunks are used to carry networking (rt_op) traffic.
•
The simplest example follows below:
node_A ---- vtrk ----
/---- vtrk ---- node_C
/
/
node_B
(vtrks share common port)
With this topology, “node_A” sees “node_C” as unreachable and vice-versa;
however, “node_A” communicates to “node_B”, and “node_B”
communicates to “node_C”.
Workaround:
CSCdr57805
•
Customers who are already using VT wraparound should continue to do
so under 9.2.3x until the fix is available.
•
BXM virtual trunking (no VT wraparound) can still be implemented
using software release 9.2.2x.
•
If virtual trunks are not yet in use, the VT wraparound solution can be
implemented in release 9.2.3x
Symptom:
Card errors show up indicating “CB_TASK is ready”
Condition:
CB_TASK gets busy processing VSI messages and this causes root task to
incorrectly assume that CB_TASK is not in a sane state. Actually a firmware
change incorrectly reduced the polling interval by the root task such that it
was polling the states of tasks sooner than it is supposed to.
Workaround:
None. Ignore these card errors as these are benign.
1.0.15 Software Release Notes for the SES Controller
82
October 19, 2001 78-11020-08
New Features supported in BXM Firmware MDA
Table 21
Bugs Fixed in MFD (continued)
CSCdr56931
Symptom:
After resetsys on PXM or bouncing the feeder/control port or reset of BXM
card, some virtual trunks go into vc failure/building vc state.
Condition:
resetting PXM or pulling out the cable connecting the BXM feeder port to
the controller or resetting the BXM cause the interface set policy parameters
to be sent to the BXM. This cause ingress BW to be recomputed. CB_TASK
passes VI numbers 0 to 31 to the CAC module which expects the range 0 to
15. This caused the problem by over-indexing the CAC structures.
Workaround:
None.
CSCdr59241
Symptom:
Building VC status on UNI ports after repeated enabling/disabling of
partition with the control port.
Cause:
Controller does not send policy parameters for control port upon enabling of
partition. When disabling partition, COS max bandwidth was zeroed out.
With no policy parameters from which to obtain the new values, COS max
bandwidth is stuck at zero; thus not allowing ant control to be established.
Workaround:
Older PXM image does send policy parameters even for the partition with
the control port. Control port does not require policy parameters to be sent
from controller. Default it to the max bandwidth configured for the partition.
1.0.15 Software Release Notes for the SES Controller
October 19, 2001 78-11020-08
83
New Features supported in BXM Firmware MDA
Table 21
Bugs Fixed in MFD (continued)
CSCdr51970
Symptom:
Change CAC policy parameters will cause the available BW for some cos to
be negative.
Condition:
Current implementation does not validate the CAC policy parameter change.
It will always take the value. However, in some cases, improper policy
parameters change will cause the avail_bw at cos level go negative. In this
particular scenario, the current used bandwidth of a cos is equal to its
reserved minimum bandwidth.Then the user changed the policy parameter to
make this cos min_bw to smaller number. Now current_used_bw for this cos
is greater than its reserved, and it has to obtained bw from the common pool
to maintain its currently used bw. However, the user changed the policy
parameter again, to increase the reserved bw for another cos, which caused
the common pool to be zero.Therefore, by normal calculation, the previous
cos avail_bw becomes to negative. Decreasing cos_min_bw to be less than it
is currently used_bw is an invalid operation and should get rejected,
otherwise it will mess up the CAC.
Workaround:
Delete some connections to release bandwidth before decreasing cos
minimum bandwidth.
CSCdr66273
Symptom:
The encoding is in the reverse of the expected value by UNI4.0 spec.
Conditions:
STD ABR connections.
Workaround:
No work around.
Table 22
Bugs Fixed in MFC
CSCdp63445
Symptom:
ABR and UBR connections loose traffic when VC shaping is turned on.
Condition:
Enabling of VC shaping on port terminating ABR and UBR connections
Workaround:
Leave VC shaping disabled.
CSCdr11396
Symptom:
Data transfer has affected while running OAM loopback
Conditions:
All user data is dropped when send in 960 cps of oam.
Workaround:
None
1.0.15 Software Release Notes for the SES Controller
84
October 19, 2001 78-11020-08
New Features supported in BXM Firmware MDA
Table 22
Bugs Fixed in MFC (continued)
CSCdp11511
Symptom:
BPX treats segment oam loopback different from end-to-end oam loopback
cells.
Conditions:
Workaround:
CSCdr13208
Symptom:
BXM CD errors while running OAM cells.
Conditions:
1.
One PVC has 2880 cps of data and 960 cps of oam cells,
2.
Another PVC has 2880 cps of data and 960 cps of oam cells,
Workaround:
None
CSCdr13196
Symptom:
BPX reports SWERR 105
Conditions:
SWERR105 logged while running OAM loopback test
Workaround:
None reset the BXM card
CSCdr13182
Symptom:
tstdelay/tstcon/tstconseg for all PVCs on that card will fail.
Conditions:
When user sending in >= 960 cps of oam loopback cells.
Workaround:
CSCdr13151
Symptom:
dspportstats always show Tx port = 0.
Conditions:
sending in >= 960 cps of oam loopback cells.
Workaround:
None.
1.0.15 Software Release Notes for the SES Controller
October 19, 2001 78-11020-08
85
New Features supported in BXM Firmware MDA
The following bugs are fixed in MFB.
Table 23
Bugs Fixed in MFB
CSCdm52254
Symptom:
Random BIP-8 errors show up on T3 when running in direct map (HEC)
mode. There is no such thing as a BIP-8 error in the direct map mode. But
this counter should report 0 in this mode.
Conditions:
This is totally random due to the fact that an uninitialized (don’t care)
counter variable is accumulated in every poll period. This counter is not even
read from hardware in the HEC mode.
Workaround:
Ignore BIP-8 errors when the T3 trunks are configured in the HEC mode.
CSCdp58969
Symptom:
cb_get.c CB_VPC_STATUS_POLL SoItcSend Failed upon VSI Failure.
Conditions:
When VSI receives and transmits lot of vsi message AAL5 drive will get into
deadlock problem if it had missed a DMA interrupt.
Workaround:
None. Upgrade to MEF or newer version of firmware.
CSCdp57596
Symptom:
CB_TASK on BXM goes into deadlock state causing VSI session to be lost
Conditions:
This happens when both Ingress and Egress queue semaphore is taken by
IDLE_TASK and it never released in an error condition
Workaround:.
None. Upgrade to MEF or newer versions of firmware.
CSCdp25220
Symptom:
Avail Buffer on BXM = 0 on LVC flapping for xtag interfaces.
Conditions:
Same as CSCdp58969. During this condition AAL5 driver doesn’t release
the transmission buffer.
Workaround:
None. Upgrade to/MEF or newer versions of firmware.
CSCdp59328
Symptom:
EPD bit was not set for interslave control vc.
Condition:
When vsi get congestion (same as CSCdp58969).
Workaround:
None. Upgrade to/MEF or newer versions of firmware.
1.0.15 Software Release Notes for the SES Controller
86
October 19, 2001 78-11020-08
New Features supported in BXM Firmware MDA
Table 23
Bugs Fixed in MFB (continued)
CSCdp92916
Symptom:
Commands executed on stdby card affect APS line.
Condition:
Series of commands executed in stdby card affects APS line.
Workaround:
None.Upgrade to MEF or newer version of firmware.
CSCdp39723
Symptom:
Aps not functioning in 9.2.21 w/FW ME18@sprintf for Bidirectional
w/Nonrevertive.
Condition:
Reversion was happening due to spurious SF/SD events.Fixed by setting the
right values for SF/SD thresholds.
Workaround:
None.Upgrade to MEF or newer version of firmware.
CSCdp20848
Symptom:
SF switchover does not occur after dncd/upcd execution on Annex B 1+1
APS.
Condition:
When the dncd command is executed, SWSW sends 0x27 CBUS message.
The handler for this message was putting the lines in loopback and shutting
down the laser. Also it was changing the line state in SoCdDown() to DOWN
state. This caused subsequent upcd (0x05/0x04) message to re-initialize the
lines disabling the S/UNI interrupts in the process.
Workaround:None.Upgrade to MEF or newer version of firmware.
CSCdp24224
Symptom:
WTR does not occur after LOS recovery on protection line.
Conditions:
The meaning of primary and secondary channels were changed immediately
upon switchover instead of waiting for the expiry of WTR. This caused the
clearing of the failure to be accounted against the secondary channel and
thus there was no WTR. Fixed by introducing a Preparation switch mode
where-in the current active channel will remain as the secondary until a
WTR occurs or a primary section mismatch pre-empts that state. At the
expiry of WTR, the preparation switch mode is complete and the current
active channel becomes the primary.
Workaround:None.Upgrade to MEF or newer version of firmware.
1.0.15 Software Release Notes for the SES Controller
October 19, 2001 78-11020-08
87
New Features supported in BXM Firmware MDA
Table 23
Bugs Fixed in MFB (continued)
CSCdp32646
Symptom:
WTR Timer does not work and reversion occurs during SF switchover.
Condition:
Added a preparation switch mode where the current active channel is the
secondary channel. At the expiry of WTR, the secondary channel is changed
to the become the primary channel.
Workaround:
None.Upgrade to MEF or newer version of firmware.
CSCdp35156
Symptom:
BPX APS reverts back to the working line before WTR time has expired.
Condition:
TR was being pre-empted by a spurious SD condition. Fixed by setting the
right thresholds for SF/SD based on BER.
Workaround:
None.Upgrade to MEF or newer version of firmware.
CSCdp60696
Symptom:
Both lines fail when only one line in alarm.
Conditions:
After the standby card comes out of reset, its S/UNI states are not reliable
for a period of 1.5 seconds and the S/UNI reports LOS clear on the WORK
line. This gets conveyed to the active card and then the Manual switch gets
priority and becomes the current local request. This causes a switch back to
WORK. When the active card’s S/UNI monitors the WORK line, it discovers
that the line is in LOS and immediately switches back. The oscillations
continue and the line goes into LOCKOUT due to excessive switching. In the
Lockout mode only the WORK line is active and thus the defect.
Workaround:
None.Upgrade to MEF or newer version of firmware.
CSCdp65320
Symptom:
Need a trap when BPX puts APS in lockout.
Condition:
Send the traps in the right sequence. First send the Lockout trap and then the
failed to switch trap if there is a switch attempt while lockout is in effect.
Workaround:
None.Upgrade to MEF or newer version of firmware.
1.0.15 Software Release Notes for the SES Controller
88
October 19, 2001 78-11020-08
New Features supported in BXM Firmware MDA
Table 23
Bugs Fixed in MFB (continued)
CSCdp25130
Symptom:
APS Non-revertive bidirectional feature.
Condition:
Resolved.
Workaround:
None.
CSCdp79156
Symptom:
TDP signalling cross connect VSI request rejected by BXM.
Conditions:
If BPX is configured with trunks and virtual trunks the virtual trunks are
initialized properly with qbin size.
Workaround:
None.Upgrade to MEF or newer version of firmware.
CSCdp62213
Symptom:
Switching from bi-direction APS to un-directional APS generates mismatch
err.
Condition:
The alarms generated while the line was in bi-dir mode was not cleared when
it was changed to uni-dir mode. Fixed by clearing all alarms when
re-configuring the lines.None.
Workaround:
None.Upgrade to MEF or newer version of firmware.
CSCdp89972
Symptom:
Node rebuild caused 3 BXM cards failed.
Condition:
Moved the allocation and initialization of the Connection database to the
SoCoEnterStandby function instead of in the 0x50 handler (SoCdUp).
Workaround:None.Upgrade to MEF or newer version of firmware.
CSCdp86147
Symptom:
The removal of Rx cable of APS trunk leading to loss of Frm and Prot Sw
Byt Fail.
Condition:
While removing the Rx cable of APS working line (configured to trunk)
working line goes to Loss of Frm and dsptrks shows the trunk in alarm. After
connecting cable back the APS Alarm status shows “Prot Sw Byt FAIL.”
Workaround:
None.Upgrade to MEF or newer version of firmware.
1.0.15 Software Release Notes for the SES Controller
October 19, 2001 78-11020-08
89
New Features supported in BXM Firmware MDA
Table 23
Bugs Fixed in MFB (continued)
CSCdp84386
Symptom:
Connectivity w/BXM lost due to missing DMA completion interrupts.
Conditions:
Aal5 driver will be in deadlock and never transmits and receives.
Workaround:
None.Upgrade to MEF or newer version of firmware.
CSCdp38148
Symptom:
Resetcd slot 11 on BPX causes local APS switching.
Conditions:
re-impose the selector and bridge states on both ACTIVE and STANDBY
cards after.
a Y-red switchover, re-discover the line states and re-execute and external
requests.Also include a STABILITY timer before the line state is processed.
Workaround:
None.Upgrade to MEF or newer version of firmware.
CSCdm92931
Symptom:
APS line switchover occurs upon card removal when lockout is set.
Condition:
Workaround:
None Upgrade to MEF or newer version of firmware.
CSCdp49749
Symptom:
node unreachable after resetting two nodes in the network.
Condition:
Workaround:
None.
CSCdp49640
Symptom:
When the FCES feature is enabled on the BXM, the NNI data transfer stops.
Conditions:
The ABR parameters like NRM,CRM,FRTT,MCR,ICR were not getting
programmed when the FCES is turned on using th cnfcon command. Adding
the connection with the FCES enabled behaved properly.
Workaround:
None.
1.0.15 Software Release Notes for the SES Controller
90
October 19, 2001 78-11020-08
New Features supported in BXM Firmware MDA
Table 23
Bugs Fixed in MFB (continued)
CSCdm62817
Symptom:
tstconseg command sometimes does not work.
Conditions:
Execute tstconseg multiple times with high loop count (10).
Workaround:
None
CSCdm84853
Symptom:
BW reported via interface load info is erroneous.
Condition:
When forward and backward BW for VSI connections is different.
Workaround:
None.
CSCdp62213
Symptom:
Switching from bi-dir to uni-dir mode APS generates APS architecture
mismatch error.
Condition:
When APS pair is configured from bi-dir mode to uni-dir mode the other side
indicates APS architecture mismatch error, and then the other side is also
configured from bi-dir mode to uni-dir mode, the APS architecture mismatch
error does not clear.
Workaround:
delete APS and then add APS again - it defaults to uni-dir.
CSCdp59729
Symptom:
addlnlocrmt causes node unreachable.
Conditions:
addlnlocrmtlp causes node unreachable even though there are other parallel
trunks.
Workaround:
No known workaround
CSCdp67673
Symptom:
dspapsln does not show ARCH_MIS any more
Conditions:
dspapsln does not show ARCH_MIS when caused for the second time on the
same trunk.
Workaround:
No known workaround.
1.0.15 Software Release Notes for the SES Controller
October 19, 2001 78-11020-08
91
New Features supported in BXM Firmware MDA
Table 23
Bugs Fixed in MFB (continued)
CSCdp46399
Symptom:
Need documentation to explain how to setup port groups for FW MEF
(me26).
Conditions:
Workaround:
No known workaround.
CSCdp49749
Symptom:
Node unreachable after resetting two nodes in the network.
Conditions:
When combus message 0x52 is sent down to BXM, we were not handling the
case when message says activate the lcn, but delete the vpi-vci pair specified
in the command.
Workaround:
None.Upgrade to MFB.
CSCdp28931
Symptom:
No RDI-P generated when loss of Cell Delineation occurs.
Condition:
Workaround:
CSCdp59727
Symptom:
Addlnlocrmt causes node unreachable.
Conditions:
Workaround: Reset the BXM card.
1.0.15 Software Release Notes for the SES Controller
92
October 19, 2001 78-11020-08
New Features supported in BXM Firmware MDA
The following bugs are fixed in MFA
Table 24
Bugs Fixed in MFA
CSCdm53420
Symptom:
switchyred causes APS line to switch when last user request is clear
Conditions:
APS 1+1 configuration. The protection line was active and the “last user
switch request” was clear. When a switchyred was performed, APS line
switched to working line active.
Workaround:
CSCdm93274
Symptom:
OC3 back card LED is wrong after reset/pull cards.
Condition:
Multiple APS lines on a card and perform switchyred when working line is
active and Secondary card is active.
Workaround:
None.
CSCdm04312
Symptom:
The problem is a false failure is declared against the SIMBA Multicast
Record RAM.
Conditions:
The problem occurs when Self Test is activated against a Y-Redundant pair
of BME Cards (BXM-622 cards loaded with the multicast BME firmware)
that have more than 1000 connections programmed through them.
Workaround:
Disable Self Test via the cnftstparm command.
CSCdm50659
Symptom:
Trunk alarms are not generated when random bit errors are injected onto a
trunk using an Adtech Sx14 test set at a rate of 10E-3. There are trunk
statistics generated but no trunk alarm because the statistics that cause
alarms on do not meet the threshold for MAJOR or MINOR alarms.
1.0.15 Software Release Notes for the SES Controller
October 19, 2001 78-11020-08
93
New Features supported in BXM Firmware MDA
Table 24
Bugs Fixed in MFA (continued)
CSCdm50659
Symptom:
Trunk alarms are not generated when random bit errors are injected onto a
trunk using an Adtech Sx14 test set at a rate of 10E-3. There are trunk
statistics generated but no trunk alarm because the statistics that cause
alarms on do not meet the threshold for MAJOR or MINOR alarms.
Conditions:
This was generated in a lab environment with test equipment that was set to
inject bit errors randomly through the entire bandwidth. Some HCS errors
were generated as well as Path unavailable and Path Farend unavailable.
Workaround:
Lowering the alarm threshold for MAJOR and MINOR HCS errors can help
to generate a trunk alarm. Use the cnflnalm command and modify the Hcserr
alarm thresholds to .01 for MAJOR and .0001 for MINOR. These thresholds
are as low as they can be set currently.
CSCdk42527
Symptom:
Rx Queue becomes full after LOS on the feeder trunk.
Conditions:
After LOS condition on the feeder trunk.
Workaround:
Reset the feeder trunk.
CSCdm16505
Symptom:
AIS not sent on VP ABRFST/ABRSTD connection.
Conditions:
LOS on trunk between 2 nodes.
Workaround:
None.
CSCdm81534
Symptom:
ICR of abrfst on BXM-155 falls down to MCR after resetcd.
Conditions:
Change the ICR after resetcd before start sending traffic.
Workaround:
None.
CSCdm61493
Symptom:
When BIP8 errors are received on an E3 line or trunk at a rate of 10E-3, the
line or trunk will not declare any alarm.
Conditions:
When high rates of BIP8 errors are received.
Workaround:
None.
1.0.15 Software Release Notes for the SES Controller
94
October 19, 2001 78-11020-08
New Features supported in BXM Firmware MDA
Table 24
Bugs Fixed in MFA (continued)
CSCdk81384
Symptom:
BXM slot errors keeps on incrementing on a BCC3 node, but the reading of
‘EAP ARFD’ should only be interpreted when using the dual receiver feature
on a BCC4 node.
Conditions:
BXM slot errors on a BCC3 node.
Workaround:
None.
CSCdk80483
Symptom:
TX cell loss counts in dsptrkerrs increase continuously.
Conditions:
When there is trunk configured.
Workaround:
None.
CSCdm04312
Symptom:
The problem is a false failure is declared against the SIMBA Multicast
Record RAM.
Conditions:
The problem occurs when Self Test is activated against a Y-Redundant pair
of BME Cards (BXM-622 cards loaded with the multicast BME firmware)
that have more than 1000 connections programmed through them.
Workaround:
Disable Self Test via the cnftstparm command.
CSCdm09295
Symptom:
Reconfig of FCES from enable to disable does not work, as a result traffic
burst is restricted to MCR.
Conditions:
Every time changing an existing connection from FCES enable to disable.
Workaround:
Delete the connection and add back a new one with FCES disable.
CSCdm39186
Symptom:
Card fatal error occurred when running in standby mode under the heat
condition. As a result, the card reset periodically.
Conditions:
Card running in standby mode under heat condition.
Workaround:
None.
1.0.15 Software Release Notes for the SES Controller
October 19, 2001 78-11020-08
95
New Features supported in BXM Firmware MDA
Table 24
Bugs Fixed in MFA (continued)
CSCdm09882
Symptom:
Log non fatal message related to the RCMP errors.
Conditions:
It is mainly seen in the heat chamber.
Workaround:
Make sure the TEST FREQUENCY and TIMEOUT variables under
cnftstparm for BXM are set to 4000/3700 level.
CSCdm31923
Symptom:
AIS/YEL alarm doesn’t go away even after the alarm is clear from the other
end
Conditions:
It happens on the E3 when the LOOP TIME parameter is set to YES in the
trunk or line configuration.
Workaround:
None
CSCdm92916
Symptom:
Operational commands (dncd, resetcd, remove) on standby card impact
active APS line When active line is PROT line and a switchover of cards
occur, WORK line becomes active line on the newly active cards.
Conditions:
APS 1+1 Annex B and PROT is active line. switchyred or resetcd on the
active card causes line to switchover from PROT to WORK.
Workaround:
None.
CSCdm92931
Symptom:
APS line switchover occurs upon card removal/insertion when lockout is set.
Conditions:
When Lockout is set, removing/inserting the card makes it happen.
CSCdm52585
Symptom:
DspVsiPartInfo shows very large Available LCN field.
Conditions:
When the sum of min-lcns is greater than the max(max lcns) on a port group.
Workaround:
None.
1.0.15 Software Release Notes for the SES Controller
96
October 19, 2001 78-11020-08
New Features supported in BXM Firmware MDA
Table 24
Bugs Fixed in MFA (continued)
CSCdp18840
Symptom:
The CBR.2 Calls do not pass traffic above 50 Cells/second.
Condition:
VSI controller establishes CBR.2 connection and it does not fill in the PCR
field.
Workaround:
Fill the PCR value also with the CR value.
CSCdp17741
Symptom:
2-portgroup card reports 1 port group at the channel stats level 2 and 3.
Condition:
When channel stats level 2 or 3 are configured on BXm-622-2 port and
BXM-155 reports only one port group.
Workaround:
Auto Route connections are not affected by this. But for VSI connections
there is no work around.
CSCdp22930
Symptoms:
Intlock missing for rd/wr operation.
Workaround:
Reassert intLock on commbus ISR to prevent SCC access from getting
interrupted.
CSCdp33894
Symptom:
standby APS line shows status as Path AIS upon switchyred or on APS
switchover on LOS.
Conditions:
switchyred on APS, the prot. line report Path AIS.
Workaround:
None. Upgrade to ME26/MED or later versions of BXM firmware.
CSCdp36324
Symptom:
last user request affects switching on BPX.
Conditions:
Workaround:
CSCdp31325
Symptom:
UBR cells are policed unnecessarily below PCR.
Conditions:
Always.
Workaround:
None.
1.0.15 Software Release Notes for the SES Controller
October 19, 2001 78-11020-08
97
New Features supported in BXM Firmware MDA
Table 24
Bugs Fixed in MFA (continued)
CSCdp36155
Symptom:
BXM-E OC3/OC12 does not show supporting APS HW 1+1 in dspcd
command and otherwise also.
Condition:
BXM-E OC3/ OC12 card with HW rev < ‘C’
Workaround:
None.
CSCdp32853
Symptom:
The BXM enhanced cards keep getting reset and card errors are logged and
node may go into degraded mode, when command “addapsln slot1.port1
slot2.port2 1” is issued.
Conditions:
BXM enhanced OC3 cards with 4 port and FW rel earlier that
M.E.22/M.F.09
Workaround:
Use one of the following options:
CSCdp17741
1.
Do not addapsln on second port onwards for BXM-E OC3 4 port card.
2.
Replace the BXM-E 4 port card with 8 ports card.
Symptom:
2-portgroup card reports 1 port group at the channel stats level 2 and 3.
Condition:
When channel stats level 2 or 3 are configured on BXm-622-2 port and
BXM-155 reports only one port group.
Workaround:
Auto Route connections are not affected by this. But for VSI connections
there is no work around.
1.0.15 Software Release Notes for the SES Controller
98
October 19, 2001 78-11020-08
New Features supported in BXM Firmware MDA
Table 24
Bugs Fixed in MFA (continued)
CSCdp11025
Symptom:
Enter the dspapsln to get the screen to display apsln status.When the
working line is taken out the LOS appears on the working line. when the
protection line is taken out both the working and protection display LOS.
When the protection line is put back in the LOS/Alarms on the protection
should clear. They do not.
Conditions:
Physically remove and add the rx or both rx and tx lines as follows:
1.
Remove the working line.
2.
Remove the protection line.
3.
Add the protection line back.
Workaround:
None.
CSCdm73220
Symptom:
Trunks or Virtual Trunks does not allow traffic going through.
Conditions:
SWSW 9.1 with ME level of firmware. Trunks or VTs configured on
BXM/BXM-E.
Workaround:
None.
The following bugs are fixed in MEC.
Table 25
Bugs Fixed in MEC
CSCdm66131
Symptom:
After addapsln trunk goes to LOS
Conditions:
Both ends have secondary card active, add aps 1+1 to one end, then add aps
to the other end, the trunk sometimes goes into LOS.
Workaround:
CSCdm64366
Symptom:
APS 1+1 manual switch sometimes does not work after a while after several
manual switch and auto switch.
Conditions:
Secondary card is active and several manual switch and auto switches are
performed.
Workaround:
1.0.15 Software Release Notes for the SES Controller
October 19, 2001 78-11020-08
99
New Features supported in BXM Firmware MDA
Table 25
Bugs Fixed in MEC (continued)
CSCdm62809
Symptom:
APS 1+1 bidirectional non-revertive switches back to working line when line
condition clears on working.
Conditions:
APS 1+1 configured in bidirection non-revertive mode.
Working line is in LOS, current active line is protection, clear LOS on
working line.
Workaround:
CSCdm69974
Symptom:
Card errors (0x25170076) occur when only one Virtual Trunk is configured
in a physical port.
Workaround:
None.
CSCdm65813
Symptom:
APS switches back o working line incorrectly.
Conditions:
Switch sequence W->P, P->W and then W->P, then cause LOS on WORK
line and put the cable back, APS switches to working line.
Workaround:
None.
CSCdm77212
Symptom:
When addshelf command is executed, it comes back with a communication
breakdown.
Condition:
Channel level stats is set to 0 so that BXM reports wrong max channels.
Workaround:
CSCdm74316
Symptom:
Re-adding VSI shelf does not work until a resetcd is executed on the LSC
control port.
Conditions:
Load information on an interface is 4 bytes more that MAX_VSI_MSG
So the message gets dropped on BXM, so VSI controller is in discovery state
forever.
Workaround:
None.
1.0.15 Software Release Notes for the SES Controller
100
October 19, 2001 78-11020-08
New Features supported in BXM Firmware MDA
Table 25
Bugs Fixed in MEC (continued)
CSCdm75722
Symptom:
No control VC after BXM is reset.
Conditions:
When resync request comes down from the VSI controller with 19 checksum
blocks, the length check done on BXM does not include padding.
Workaround:
None.
CSCdm74968
Symptom:
0B card error causing BXM to reset.
Conditions:
Over night jobs running on controller cards.
Workaround:
None.
CSCdp02190
Symptom:
tstdelay timed out when going through BNI trunk.
Conditions:
more that 12 VTs on an interface causes wrong port-vi mapping while
considering STI_SHIFT/NO_SHIFT from 13 th VT/port onwards.
Workaround:
None.
CSCdm78335
Symptom:
dspvsistatus rarely shows the VSI programming status as Done
Conditions:
Primary and secondary port has two different VPI range.
Workaround:
None.
CSCdm26752
Symptom:
Card errors continuously logged with “SoItcSend failed” message.
Conditions:
RAS oam_lpbk is on and switchyred is executed several times in a job.
Workaround:
None.
CSCdm93839
Symptom:
Card resets on receiving oam loopback cells at high rate.
Conditions:
oamlpbk is enabled with high OAM traffic on large number of connections.
Workaround:
None.
1.0.15 Software Release Notes for the SES Controller
October 19, 2001 78-11020-08
101
New Features supported in BXM Firmware MDA
Table 25
Bugs Fixed in MEC (continued)
CSCdm52254
Symptom:
BIP-8 code errs occurs on routing trunks.
Conditions:
T3 card used in HEC mode can randomly have this problem.
Workaround:
None.
CSCdm44183
Symptom:
BXM-155 4DX was not able to recover after resetting the card.
Conditions:
Traffic is sent at a rate >= 383 cps on a terminated connection on BXM-E
card and then card is reset.
Workaround:
None.
CSCdm90997
Symptom:
BXM-E trunk and port stats are always zero in TX direction.
Condition:
port terminated on BXM-E card or trunk passing through BXM-E card.
Workaround:
None.
CSCdm80991
Symptom:
Unable to add 3 segment connections using CM GUI.
Condition:
Feeder connected to BXM card of BPX routing node and for, BXM trunk
configuration, ILMI/LMI protocol is enabled as CARD based.
Workaround:
None.
CSCdm82688
Symptom:
Traffic Shaping problems with VT with and without wrap-around solution.
Conditions:
Large deviations in CDV values.
Workaround:
None.
1.0.15 Software Release Notes for the SES Controller
102
October 19, 2001 78-11020-08
New Features supported in BXM Firmware MDA
Table 25
Bugs Fixed in MEC (continued)
CSCdm94372
Symptom:
(see explanation
below)
Trunks sometimes drop cbr traffic.
Conditions:
If a trunk is configured to full line rate on BXM cards, then traffic is dropped.
Workaround:
None.
CSCdp00063
Symptom:
Node unreachability is experienced on VTs (virtual trunks).
Conditions:
Multiple VTs are configured on a trunk interface of the BXM/BXM-E.
Workaround:
Configure only one VT per trunk interface.
Logic to calculate actual cell transmission rate in a BXM card is as follows (CSCdm94372):
if (configured cell rate == full line cell rate) then transmitted cell rate = full line cell rate
else transmitted cell rate = from equation below or from table 1
1470588
transmitted – cell – rate = --------------------------------------------------------------------------------------------------------------------------------------------1470588
1 -⎞
⎛ integer – round – up ⎛ ------------------------------------------------------------⎞ + -------⎝
⎝ configured – cell – rate⎠ 256⎠
Example 0-1
If a trunk is configured at 100,000 CPS, the actual transmitted cell rate is then 98,013 CPS any traffic
sent over 98,013 CPS would be discarded. Therefore, only rates in the table or computed from the
equation should be used. Otherwise cell loss may be experienced
1.0.15 Software Release Notes for the SES Controller
October 19, 2001 78-11020-08
103
New Features supported in BXM Firmware MDA
The following is the list of bugs fixed in release MEB.
Table 26
Bugs Fixed in MEB
CSCdm50469
Symptom:
Software error 105 and malloc card errors happened continuously.
Conditions:
When jobs that cause reroutes of connections (e.g. switchcc, hitless rebuild)
are run for a long time, sometimes BXM card freezes with malloc card errors
and software error 105.
Workaround:
None.
CSCdm50723
Symptom:
After deleting APS, switchyred causes temporary LOS when the other end
still has APS.
Conditions:
One end has APS 1+1, other end was added with APS 1+1 and line is up
between the two ends. Then APS is deleted from one end. The primary card
is active on non APS end. On switchyred on the non APS end there is a
temporary LOS. If APS was never added to one end, then switchyred does
not result in temporary LOS.
Workaround:
Instead of deleting APS first and then doing a switchyred, do a switchyred
first and then delete APS. This does not result in temporary LOS.
CSCdm63038
Symptom:
BXM card fails with breakpoint error.
Conditions:
When tx cell rate of a trunk is reduced to zero, BXM card fails with break
point error (division by zero).
Workaround:
None.
1.0.15 Software Release Notes for the SES Controller
104
October 19, 2001 78-11020-08
New Features supported in BXM Firmware MDA
The following is the list of bugs fixed in release MEA:
Table 27
Bugs Fixed in release MEA
CSCdm09882
Symptom:
Log non fatal message related to RCMP errors.
Conditions:
It is mainly seen in the heat chamber.
Workaround:
None.
CSCdm18186
Symptom:
AIS status could be randomly be displayed in dspcon.
Conditions:
When the connection AIS signal is constantly changing, the
dspcon/dspchstats OAM status will not be accurate for all the connections
on the card.
Workaround:
None.
CSCdm26380
Symptom:
Software error 9098 occured during switchyred BXM.
Conditions:
This problem occurs on cards with the APS channels halved option set and
then doing a cnfrsrc on a port that belongs to the second port group. Note that
this fix will cause a card mismatch on active cards with channel halved
option turned on.
Workaround:
None.
CSCdm31923
Symptom:
AIS/YEL alarm doesn’t go away even after the alarm is clear from the other
end.
Conditions:
It happens on the E3 when the LOOP TIME parameter is set to YES in the
trunk or line configuration.
Workaround:
None.
CSCdm37519
Symptom:
Trunks go to Communication Fail after burning firmware.
Condition:
When MC10 is burnt into BXM-OC12 with trunks.
Workaround:
None.
1.0.15 Software Release Notes for the SES Controller
October 19, 2001 78-11020-08
105
New Features supported in BXM Firmware MDA
Table 27
Bugs Fixed in release MEA
CSCdm37709
Symptom:
APS line fails to clear channel mismatch after lockout.
Conditions:
Bi-direction APS 1+1. Local end has locked out of protection set. Then
WORK cable is pulled out on local end to cause LOS. Lockout is then
cleared and then the WORK cable is put back. This causes a channel
mismatch on the far end and the mismatch never clears.
Workaround:
None.
CSCdm38647
Symptom:
This bug has been fixed in MEA such that the firmware reports the correct
number of port groups. The side effect of this fix is that the Switch Software
could mismatch the BXM card. If there is a card mismatch then down all the
lines/trunks on the card and up them again.
Conditions:
When the user loads the MEA firmware on the BXM card running MDA with
APS halved channeled enabled, then the card will come up in mismatched
state.
Workaround:
None.
CSCdm46658
Symptom:
switchapsln command does not work for APS AnnexB line.
Conditions:
Annex B configuration if hitless rebuild is done when active line is PROT,
then switchapsln does not work after hitless rebuild.
Workaround:
None.
1.0.15 Software Release Notes for the SES Controller
106
October 19, 2001 78-11020-08
New Features supported in BXM Firmware MDA
The following is the list of bugs fixed in release MDA:
Table 28
Bugs Fixed in release MDA
CSCdm38647
Symptom:
MDA fw may report incorrect number of port-groups when APS channels are
set to halved.
Conditions:
When user attempts to add all the channels available on the card on one
port-group, it may be allowed even though the BXM may not have enough
memory to support it. Also, this may cause a mismatch state when MDB
firmware is burnt.
Workaround:
Down all the line/trunks on the card and up them again.
CSCdm23713
Symptom:
VI numbers are not modified by firmware.
Conditions:
When one or more trunks are failed in the network, there may be a combreak
in the network.
Workaround:
Set all the Virtual trunks to restrict CC traffic.
CSCdm23827
Symptom:
APS alarm may clear on switchyred.
Conditions:
After entering the switchyred command, an existing a LOS/LOF alarm may
get cleared. This will only happen when the line has switched to protection
before the card switchover is performed.
Workaround:
None.
CSCdm23752
Symptom:
BXM fw does not allow a networking channel on VTs to configured for
egress only.
Conditions:
BXM firmware allowed configuration of networking channel to be
bidirectional only.
Workaround:
None
1.0.15 Software Release Notes for the SES Controller
October 19, 2001 78-11020-08
107
New Features supported in BXM Firmware MDA
Firmware Filenames and Sizes
BXMMFL.000
65536
BXMMFL.001
65536
BXMMFL.002
65536
BXMMFL.003
65536
BXMMFL.004
65536
BXMMFL.005
65536
BXMMFL.006
65536
BXMMFL.007
65536
BXMMFL.008
65536
BXMMFL.009
65536
BXMMFL.010
65536
BXMMFL.011
65536
BXMMFL.012
65536
BXMMFL.013
65536
BXMMFL.014
65536
BXMMFL.015
65536
BXMMFL.016
65536
BXMMFL.017
65536
BXMMFL.018
65536
BXMMFL.019
65536
BXMMFL.020
65536
BXMMFL.021
65536
BXMMFL.022
65536
BXMMFL.023
65536
BXMMFL.024
60128
BXMMFL.025
14
BXMMFL.026
2
BXMMFL.IMG
784
BXMMFL.img
784
1.0.15 Software Release Notes for the SES Controller
108
October 19, 2001 78-11020-08
Related Documentation
Related Documentation
The following Cisco publications contain additional information related to the operation of this product
and associated equipment in a Cisco WAN switching network.
Table 1
SES PNNI Controller Release 1.1 Documentation
Title
Description
Cisco SES PNNI Controller Software Configuration Guide, Describes how to configure, operate, and maintain the SES
Release 1.1
PNNI Controller.
DOC-7813539=
Cisco SES PNNI Controller Software Command Reference, Provides a description of the commands used to configure and
operate the SES PNNI Controller.
Release 1.1
DOC-7813541=
Cisco MGX and SES PNNI Network Planning Guide
DOC-7813543=
Provides guidelines for planning a PNNI network that uses the
MGX 8850 and the MGX 8950 switches and the BPX 8600
switches. When connected to a PNNI network, each BPX 8600
series switch requires a SES for PNNI route processing.
Obtaining Documentation
The following sections explain how to obtain documentation from Cisco Systems.
World Wide Web
You can access the most current Cisco documentation on the World Wide Web at the following URL:
http://www.cisco.com
Translated documentation is available at the following URL:
http://www.cisco.com/public/countries_languages.shtml
Documentation CD-ROM
Cisco documentation and additional literature are available in a Cisco Documentation CD-ROM
package, which is shipped with your product. The Documentation CD-ROM is updated monthly and may
be more current than printed documentation. The CD-ROM package is available as a single unit or
through an annual subscription.
1.0.15 Software Release Notes for the SES Controller
October 19, 2001 78-11020-08
109
Obtaining Technical Assistance
Ordering Documentation
Cisco documentation is available in the following ways:
•
Registered Cisco Direct Customers can order Cisco product documentation from the Networking
Products MarketPlace:
http://www.cisco.com/cgi-bin/order/order_root.pl
•
Registered Cisco.com users can order the Documentation CD-ROM through the online Subscription
Store:
http://www.cisco.com/go/subscription
•
Nonregistered Cisco.com users can order documentation through a local account representative by
calling Cisco corporate headquarters (California, USA) at 408 526-7208 or, elsewhere in North
America, by calling 800 553-NETS (6387).
Documentation Feedback
If you are reading Cisco product documentation on Cisco.com, you can submit technical comments
electronically. Click Leave Feedback at the bottom of the Cisco Documentation home page. After you
complete the form, print it out and fax it to Cisco at 408 527-0730.
You can e-mail your comments to [email protected].
To submit your comments by mail, use the response card behind the front cover of your document, or
write to the following address:
Cisco Systems
Attn: Document Resource Connection
170 West Tasman Drive
San Jose, CA 95134-9883
We appreciate your comments.
Obtaining Technical Assistance
Cisco provides Cisco.com as a starting point for all technical assistance. Customers and partners can
obtain documentation, troubleshooting tips, and sample configurations from online tools by using the
Cisco Technical Assistance Center (TAC) Web Site. Cisco.com registered users have complete access to
the technical support resources on the Cisco TAC Web Site.
Cisco.com
Cisco.com is the foundation of a suite of interactive, networked services that provides immediate, open
access to Cisco information, networking solutions, services, programs, and resources at any time, from
anywhere in the world.
Cisco.com is a highly integrated Internet application and a powerful, easy-to-use tool that provides a
broad range of features and services to help you to
•
Streamline business processes and improve productivity
•
Resolve technical issues with online support
1.0.15 Software Release Notes for the SES Controller
110
October 19, 2001 78-11020-08
Obtaining Technical Assistance
•
Download and test software packages
•
Order Cisco learning materials and merchandise
•
Register for online skill assessment, training, and certification programs
You can self-register on Cisco.com to obtain customized information and service. To access Cisco.com,
go to the following URL:
http://www.cisco.com
Technical Assistance Center
The Cisco TAC is available to all customers who need technical assistance with a Cisco product,
technology, or solution. Two types of support are available through the Cisco TAC: the Cisco TAC
Web Site and the Cisco TAC Escalation Center.
Inquiries to Cisco TAC are categorized according to the urgency of the issue:
•
Priority level 4 (P4)—You need information or assistance concerning Cisco product capabilities,
product installation, or basic product configuration.
•
Priority level 3 (P3)—Your network performance is degraded. Network functionality is noticeably
impaired, but most business operations continue.
•
Priority level 2 (P2)—Your production network is severely degraded, affecting significant aspects
of business operations. No workaround is available.
•
Priority level 1 (P1)—Your production network is down, and a critical impact to business operations
will occur if service is not restored quickly. No workaround is available.
Which Cisco TAC resource you choose is based on the priority of the problem and the conditions of
service contracts, when applicable.
Cisco TAC Web Site
The Cisco TAC Web Site allows you to resolve P3 and P4 issues yourself, saving both cost and time. The
site provides around-the-clock access to online tools, knowledge bases, and software. To access the
Cisco TAC Web Site, go to the following URL:
http://www.cisco.com/tac
All customers, partners, and resellers who have a valid Cisco services contract have complete access to
the technical support resources on the Cisco TAC Web Site. The Cisco TAC Web Site requires a
Cisco.com login ID and password. If you have a valid service contract but do not have a login ID or
password, go to the following URL to register:
http://www.cisco.com/register/
If you cannot resolve your technical issues by using the Cisco TAC Web Site, and you are a Cisco.com
registered user, you can open a case online by using the TAC Case Open tool at the following URL:
http://www.cisco.com/tac/caseopen
If you have Internet access, it is recommended that you open P3 and P4 cases through the Cisco TAC
Web Site.
1.0.15 Software Release Notes for the SES Controller
October 19, 2001 78-11020-08
111
Obtaining Technical Assistance
Cisco TAC Escalation Center
The Cisco TAC Escalation Center addresses issues that are classified as priority level 1 or priority
level 2; these classifications are assigned when severe network degradation significantly impacts
business operations. When you contact the TAC Escalation Center with a P1 or P2 problem, a Cisco TAC
engineer will automatically open a case.
To obtain a directory of toll-free Cisco TAC telephone numbers for your country, go to the following
URL:
http://www.cisco.com/warp/public/687/Directory/DirTAC.shtml
Before calling, please check with your network operations center to determine the level of Cisco support
services to which your company is entitled; for example, SMARTnet, SMARTnet Onsite, or Network
Supported Accounts (NSA). In addition, please have available your service agreement number and your
product serial number.
This document is to be used in conjunction with the documents listed in the “” section.
AccessPath, AtmDirector, Browse with Me, CCIP, CCSI, CD-PAC, CiscoLink, the Cisco Powered Network logo, Cisco Systems Networking
Academy, the Cisco Systems Networking Academy logo, Fast Step, Follow Me Browsing, FormShare, FrameShare, GigaStack, IGX, Internet
Quotient, IP/VC, iQ Breakthrough, iQ Expertise, iQ FastTrack, the iQ Logo, iQ Net Readiness Scorecard, MGX, the Networkers logo, Packet,
RateMUX, ScriptBuilder, ScriptShare, SlideCast, SMARTnet, TransPath, Unity, Voice LAN, Wavelength Router, and WebViewer are trademarks
of Cisco Systems, Inc.; Changing the Way We Work, Live, Play, and Learn, Discover All That’s Possible, and Empowering the Internet Generation,
are service marks of Cisco Systems, Inc.; and Aironet, ASIST, BPX, Catalyst, CCDA, CCDP, CCIE, CCNA, CCNP, Cisco, the Cisco Certified
Internetwork Expert logo, Cisco IOS, the Cisco IOS logo, Cisco Press, Cisco Systems, Cisco Systems Capital, the Cisco Systems logo,
Enterprise/Solver, EtherChannel, EtherSwitch, FastHub, FastSwitch, IOS, IP/TV, LightStream, MICA, Network Registrar, PIX, Post-Routing,
Pre-Routing, Registrar, StrataView Plus, Stratm, SwitchProbe, TeleRouter, and VCO are registered trademarks of Cisco Systems, Inc. and/or its
affiliates in the U.S. and certain other countries.
All other trademarks mentioned in this document or Web site are the property of their respective owners. The use of the word partner does not imply
a partnership relationship between Cisco and any other company. (0108R)Copyright © 2001, Cisco Systems, Inc.
All rights reserved.
1.0.15 Software Release Notes for the SES Controller
112
October 19, 2001 78-11020-08