PDF

Installation Notes for the Catalyst 2360 Switch
Reversible Fan Module
For more information about using the fan module, see the Catalyst 2360 Switch Hardware Installation
Guide on Cisco.com.
For translations of the safety warnings, see the Regulatory Compliance and Safety Information for the
Catalyst 2360 Switch on Cisco.com.
Contents
•
Product Overview, page 1
•
Fan Module Installation, page 4
•
Finding the Fan Module Serial Number, page 6
•
Technical Specifications, page 6
•
Related Publications, page 7
•
Obtaining Documentation and Submitting a Service Request, page 7
Product Overview
The switch has a dual-direction fan module that comprises two fans (Figure 1). The orientation of the
fan module sets the direction of the air flow through the switch—either air intake at the ports or air
exhaust at the ports. The switch air flow direction should match the air flow direction of other devices
in the same rack. To change the air flow direction, remove the fan module, rotate it 180 degrees
(Figure 2), and re-insert it.
The fan module is hot-swappable.
Table 1
Fan Module Part Number and Description
Part number
Description
C2360-FAN
Reversible fan module with two fans
Americas Headquarters:
Cisco Systems, Inc., 170 West Tasman Drive, San Jose, CA 95134-1706 USA
Product Overview
Figure 1
Fan Module
1
2
C2360-FAN
AIRFLOW DIRECTION
254084
4
3
3
1
Fan module
3
Fans
2
Air flow direction indicator
4
Captive screw
Figure 2
Fan Module Rotation
C2360-FAN
AIRFLOW DIRECTION
1
C2360-FAN
AIRFLOW DIRECTION
254093
2
Figure 3 shows the fan orientation for airflow into the ports and shows the original switch chassis.
Installation Notes for the Catalyst 2360 Switch Reversible Fan Module
2
OL-22152-02
Product Overview
Figure 3
Fan Orientation for Airflow into Switch Ports (Original Switch Chassis)
EXHAUST AT PORTS
C2360-FAN
MGMT
BASE T
EXHAUST AT PORTS
AIRFLOW DIRECTION
INTAKE AT PORTS
E
INTAKE AT PORTS
CONSOL
100-240~
PWR OK
100-240~
135W
2-1A,
50-60H
z
135W
254086
C2360-FAN
AIRFLOW DIRECTION
PWR OK
2-1A,
50-60H
z
Figure 4 shows the fan orientation for airflow into the ports and shows an updated switch chassis.
Figure 4
Fan Orientation for Airflow into Switch Ports (Updated Switch Chassis)
R
E
V
E
R
S
IB
LE
FA
N
C2360-FAN
EXHAUST AT PORTS
AIRFLOW DIRECTION
AIRFLOW IN PORTS
R
E
V
E
R
S
IB
LE
FA
P
S
U
1
MGMT
BASE T
100-240~
PWR OK
P
S
U
2
AIRFLOW OUT PORTS
N
E
AIRFLOW IN PORTS
CONSOL
100-240~
135W
2-1A,
50-60H
z
135W
254801
C2360-FAN
AIRFLOW DIRECTION
PWR OK
2-1A,
50-60H
z
Figure 5 shows the fan orientation for airflow out of the ports and shows an original switch chassis.
Installation Notes for the Catalyst 2360 Switch Reversible Fan Module
OL-22152-02
3
Fan Module Installation
Figure 5
Fan Orientation for Airflow out of Switch Ports (Original Switch Chassis)
C2360-FAN
AIRFLOW DIRECTION
EXHAUST AT PORTS
INTAKE AT PORTS
MGMT
BASE T
EXHAUST AT PORTS
E
INTAKE AT PORTS
CONSOL
100-240~
PWR OK
100-240~
135W
2-1A,
50-60H
z
135W
254087
C2360-FAN
AIRFLOW DIRECTION
PWR OK
2-1A,
50-60H
z
Figure 6 shows the fan orientation for airflow out of the ports and shows an updated switch chassis.
Figure 6
Fan Orientation for Airflow Out of Ports (Updated Switch Chassis)
R
E
V
E
R
S
IB
LE
FA
N
C2360-FAN
AIRFLOW DIRECTION
AIRFLOW OUT PORTS
INTAKE AT PORTS
R
E
V
E
R
S
IB
LE
FA
P
S
U
1
MGMT
BASE T
100-240~
PWR OK
P
S
U
2
AIRFLOW OUT PORTS
N
E
AIRFLOW IN PORTS
CONSOL
100-240~
z
135W
2-1A,
50-60H
z
135W
254802
AIRFLOW DIRECTION
C2360-FAN
PWR OK
2-1A,
50-60H
An airflow direction label is on each side of the fan slot in the switch back panel. Align the fan-module
airflow direction indicator (Figure 1) with one of the direction indicators on the back panel (Figures 3
through 6).
Fan Module Installation
•
Installation Guidelines, page 5
•
Tools that You Need, page 5
•
Installing a Fan Module, page 5
Installation Notes for the Catalyst 2360 Switch Reversible Fan Module
4
OL-22152-02
Fan Module Installation
Installation Guidelines
•
Do not force the fan module into the slot. The switch pins can be damaged if they are not aligned
with the module.
•
A partially connected fan module can disrupt system operation.
•
The fan module is hot-swappable. When replacing a fan, complete the replacement procedure before
a CLI message shows that the switch is overheating (approximately 5 minutes).
•
The switch continues to operate when one fan fails. If one fan fails, the Fan LED turns amber. If the
second fan fails, the switch sends an error message, writes a failure log to flash memory, and shuts
down.
•
Make sure that the fan module is securely seated before you move the switch.
Warning
Do not reach into a vacant slot or chassis while you install or remove a module or a fan. Exposed
circuitry could constitute an energy hazard. Statement 206
Warning
Only trained and qualified personnel should be allowed to install, replace, or service this equipment.
Statement 1030
Tools that You Need
You need a flat-blade screwdriver to loosen the captive screw on the fan module.
Installing a Fan Module
Note
Warning
See a video demonstration of the fan installation:
http://www.cisco.com/en/US/prod/collateral/switches/ps5718/ps10920/vds_cis_108148_cat2360_fan_i
nstallation.html
Do not reach into a vacant slot or chassis while you install or remove a module or a fan. Exposed
circuitry could constitute an energy hazard. Statement 206
Step 1
Using a flat blade screwdriver, loosen the captive screw.
Step 2
Grasp the captive screw and pull out the fan module.
Caution
Replace a failed fan module before a CLI message shows that the switch is overheating (approximately
5 minutes).
Step 3
Align the air-flow direction indicator on the fan module with the one of the direction indicators on the
switch (Figures 3 through 6), and push the module into the slot. When correctly inserted, the fan module
is flush with the switch rear panel.
Installation Notes for the Catalyst 2360 Switch Reversible Fan Module
OL-22152-02
5
Finding the Fan Module Serial Number
Step 4
Tighten the captive screw. When the fan is operating, the fan LED on the switch front panel is green.
The switch continues to operate when one fan fails. If one fan fails, the Fan LED turns amber. If the
second fan fails, the switch sends an error message, writes a failure log to flash memory, and shuts down.
Finding the Fan Module Serial Number
If you contact Cisco Technical Assistance regarding a fan module, you need to know the serial number.
Figure 7 shows the serial number location.
Catalyst 2360 Switch Fan Module Serial Number
207618SN, 781-00680-01
Figure 7
SN: XXXNNNNXXXX
Technical Specifications
Table 2
Fan Module Environmental and Physical Specifications
Environmental Ranges
Operating temperature
23 to 113° F (–5 to 45° C)
Storage temperature
–40 to 158° F (–40 to 70° C)
Relative humidity
10 to 90% (noncondensing)
Altitude
Up to 10,000 ft (3049 m)
Physical Specification
Dimensions (H x W x D)
1.64 x 1.81 x 7.89 in. (4.2 x 4.6 x 20 cm)
Weight
0.54 lb. (0.25 kg)
Installation Notes for the Catalyst 2360 Switch Reversible Fan Module
6
OL-22152-02
Related Publications
Table 2
Fan Module Environmental and Physical Specifications (continued)
Operating Specification
Airflow
60 cubic feet per minute (CFM)
Related Publications
•
Catalyst 2360 Switch Getting Started Guide
•
Catalyst 2360 Switch Hardware Installation Guide
•
Regulatory Compliance and Safety Information for the Catalyst 2360 Switch
•
Installation Notes for the Catalyst 2360 Switch Power Supply Module
•
Installation Notes for the Catalyst 2360 Switch Fan Module
•
Release Notes for the Catalyst 2360 Switch
•
Catalyst 2360 Switch Software Configuration Guide
•
Catalyst 2360 Switch Command Reference
•
Catalyst 2360 Switch System Message Guide
•
Cisco IOS Software Installation Document
Obtaining Documentation and Submitting a Service Request
For information on obtaining documentation, submitting a service request, and gathering additional
information, see the monthly What’s New in Cisco Product Documentation, which also lists all new and
revised Cisco technical documentation, at:
http://www.cisco.com/en/US/docs/general/whatsnew/whatsnew.html
Subscribe to the What’s New in Cisco Product Documentation as a Really Simple Syndication (RSS) feed
and set content to be delivered directly to your desktop using a reader application. The RSS feeds are a free
service and Cisco currently supports RSS Version 2.0.
This document is to be used in conjunction with the documents listed in the “Related Publications” section.
Cisco and the Cisco Logo are trademarks of Cisco Systems, Inc. and/or its affiliates in the U.S. and other countries. A listing of Cisco's trademarks
can be found at www.cisco.com/go/trademarks. Third party trademarks mentioned are the property of their respective owners. The use of the word
partner does not imply a partnership relationship between Cisco and any other company. (1005R)
Any Internet Protocol (IP) addresses used in this document are not intended to be actual addresses. Any examples, command display output, and
figures included in the document are shown for illustrative purposes only. Any use of actual IP addresses in illustrative content is unintentional and
coincidental.
© 2010 Cisco Systems, Inc. All rights reserved.
Installation Notes for the Catalyst 2360 Switch Reversible Fan Module
OL-22152-02
7
Obtaining Documentation and Submitting a Service Request
Installation Notes for the Catalyst 2360 Switch Reversible Fan Module
8
OL-22152-02