PDF

Installation Notes for the Catalyst 2360 Switch
Power Supply Module
For more information about using the switch power supply module with the switch, see the
Catalyst 2360 Switch Hardware Installation Guide on Cisco.com.
For translations of the safety warnings, see the Regulatory Compliance and Safety Information for the
Catalyst 2360 Switch on Cisco.com.
Contents
•
Product Overview, page 1
•
Power Supply Module Installation, page 3
•
Finding the Power Supply Serial Number, page 4
•
Technical Specifications, page 5
•
Related Publications, page 6
•
Obtaining Documentation and Submitting a Service Request, page 6
Product Overview
Table 1
Power Supply Module Part Number and Description
Part number
Description
PWR-C49-300AC
135-W AC power supply module
The 135-W AC power supply module is an autoranging unit that supports input voltages between 100
and 240 VAC.
The power supply module ships with an 18-AWG power cord.
Figure 1 shows the power supply module.
Americas Headquarters:
Cisco Systems, Inc., 170 West Tasman Drive, San Jose, CA 95134-1706 USA
Product Overview
Figure 1
135-W AC Power Supply Module
1
2
100-240
~
3
254083
PWR OK
2-1A,
50-60Hz
4
135W
5
6
1
Power supply
4
Latch release lever
2
Power cord connector
5
LED
3
Locking latch
6
Captive screw
The power supply module has one status LED. (Table 2)
Table 2
Power Supply Module LED
Power Supply Module LED
Off
No AC input power or DC output failure
Green
AC input power present and DC output OK
Do not operate the switch with an empty power supply slot. If no power supply is installed in a power
supply slot, install a power supply slot cover (Figure 2).
Figure 2
Power Supply Slot Cover
1
2
254085
3
1
Blank cover
2
Release latch
3
Captive screw
Installation Notes for the Catalyst 2360 Switch Power Supply Module
2
OL-22151-02
Power Supply Module Installation
Power Supply Module Installation
•
Installation Guidelines, page 3
•
Tools that You Need, page 3
•
Installing or Replacing a Power Supply, page 3
Installation Guidelines
Caution
Warning
•
Do not force the power supply module into the slot. The switch pins can be damaged if they are not
aligned with the module.
•
A partially connected power supply module can disrupt the system operation.
•
Unplug the power cord from the power-supply module before removing or installing the module.
Do not operate the switch with an empty power-supply module slot. For proper chassis cooling, both
module slots must be populated with either a power supply or a blank cover.
Blank faceplates and cover panels serve three important functions: they prevent exposure to
hazardous voltages and currents inside the chassis; they contain electromagnetic interference (EMI)
that might disrupt other equipment; and they direct the flow of cooling air through the chassis. Do not
operate the system unless all cards, faceplates, front covers, and rear covers are in place.
Statement 1029
•
Make sure that the power supply modules are securely seated before you move the switch.
Warning
Do not reach into a vacant slot or chassis while you install or remove a module or a fan. Exposed
circuitry could constitute an energy hazard. Statement 206
Warning
Only trained and qualified personnel should be allowed to install, replace, or service this equipment.
Statement 1030
Tools that You Need
You need a flat-blade screwdriver to loosen the captive screw on the power supply.
Installing or Replacing a Power Supply
Note
Figure 3 shows an updated switch chassis, but the process applies to any switch chassis.
Installation Notes for the Catalyst 2360 Switch Power Supply Module
OL-22151-02
3
Finding the Power Supply Serial Number
Step 1
Turn off the power at its source. If you are not replacing a power supply, go to Step 4.
Step 2
Unplug the power cord from the power supply module connector.
Step 3
Using a flat head screwdriver, loosen the captive screw.
Step 4
Move the release latch on the left side of the power supply to the right to unlock it. If you are not
replacing a power supply, go to Step 6.
Step 5
Grasp the captive screw, and pull out the power supply. (Figure 3).
Caution
Do not leave the power-supply slot open for more than 90 seconds while the switch is operating.
Step 6
Install the new power supply into the slot, and gently push it in. (Figure 3). When correctly inserted, the
power supply is flush with the switch rear panel.
Step 7
Move the release latch left, to the locked position.
Figure 3
Installing a Power Supply in the Switch
R
E
V
E
R
S
IB
LE
FA
N
P
S
U
1
MGMT
BASE T
AIRFLOW DIRECTION
E
100-240~
C2360-FAN
PWR OK
P
S
U
2
AIRFLOW IN PORTS
CONSOL
135W
PWR OK
254089
2-1A
50-60H
z
100-240~
2-1A
50-60H
z
135W
Step 8
Tighten the captive screw.
Step 9
Plug the power cord into the power supply and into an AC-power outlet. Turn on the power at the power
source.
Step 10
Confirm that the LED on the power supply and the Power LED on the switch front panel are green. See
Table 2 for a description of the power supply module LED.
Finding the Power Supply Serial Number
If you contact Cisco Technical Assistance regarding a power supply module, you need to know the serial
number. Figure 4 shows the serial number location.
Installation Notes for the Catalyst 2360 Switch Power Supply Module
4
OL-22151-02
Technical Specifications
Figure 4
Catalyst 2360 Switch Power Supply Serial Number
207619SN, 781-00681-01
SN: XXXNNNNXXXX
Technical Specifications
Table 3
Power Supply Module Environmental and Physical Specifications
Environmental Ranges
Operating temperature
32 to 113° F (0 to 45° C)
Storage temperature
–40 to 158° F (–40 to 70° C)
Relative humidity
10 to 90% (noncondensing)
Altitude
Up to 10,000 ft (3049 m)
Physical Specifications
Weight
C2360-PWR-135WAC
C2360-PWR-COVER
1.7 lb (0.77 kg)
0.165 lb (0.075 kg)
Dimensions (H x W x D)
C2360-PWR-135WAC
C2360-PWR-COVER
1.5 x 4 x 7.5 in (3.8 x 10.2 x 19.1 cm)
1.5 x 4 x 1 in (3.8 x 10.2 x 2.5 cm)
Installation Notes for the Catalyst 2360 Switch Power Supply Module
OL-22151-02
5
Related Publications
Table 4
Power Supply Module Power Specifications
Power Specifications
Maximum output power
135 W
Input voltage range and frequency
100–240 VAC, 50–60 Hz
Input current
2–1 A
Output ratings
12 V @ 11.3 A
Total input BTU1
Total output BTU
548 BTUs per hour
1
460 BTUs per hour
1. The total input and total output BTU ratings refer to input power to the power supply and output power to the switch. The
BTU ratings are based on 100 VAC.
Related Publications
•
Catalyst 2360 Switch Getting Started Guide
•
Catalyst 2360 Switch Hardware Installation Guide
•
Regulatory Compliance and Safety Information for the Catalyst 2360 Switch
•
Installation Notes for the Catalyst 2360 Switch Power Supply Module
•
Installation Notes for the Catalyst 2360 Switch Fan Module
•
Release Notes for the Catalyst 2360 Switch
•
Catalyst 2360 Switch Software Configuration Guide
•
Catalyst 2360 Switch Command Reference
•
Catalyst 2360 Switch System Message Guide
•
Cisco IOS Software Installation Document
Obtaining Documentation and Submitting a Service Request
For information on obtaining documentation, submitting a service request, and gathering additional
information, see the monthly What’s New in Cisco Product Documentation, which also lists all new and
revised Cisco technical documentation, at:
http://www.cisco.com/en/US/docs/general/whatsnew/whatsnew.html
Subscribe to the What’s New in Cisco Product Documentation as a Really Simple Syndication (RSS) feed
and set content to be delivered directly to your desktop using a reader application. The RSS feeds are a free
service and Cisco currently supports RSS Version 2.0.
This document is to be used in conjunction with the documents listed in the “Related Publications” section.
Cisco and the Cisco Logo are trademarks of Cisco Systems, Inc. and/or its affiliates in the U.S. and other countries. A listing of Cisco's trademarks
can be found at www.cisco.com/go/trademarks. Third party trademarks mentioned are the property of their respective owners. The use of the word
partner does not imply a partnership relationship between Cisco and any other company. (1005R)
Installation Notes for the Catalyst 2360 Switch Power Supply Module
6
OL-22151-02
Obtaining Documentation and Submitting a Service Request
Any Internet Protocol (IP) addresses used in this document are not intended to be actual addresses. Any examples, command display output, and
figures included in the document are shown for illustrative purposes only. Any use of actual IP addresses in illustrative content is unintentional and
coincidental.
© 2010 Cisco Systems, Inc. All rights reserved.
Installation Notes for the Catalyst 2360 Switch Power Supply Module
OL-22151-02
7
Obtaining Documentation and Submitting a Service Request
Installation Notes for the Catalyst 2360 Switch Power Supply Module
8
OL-22151-02