PDF

Installation and Warranty Notes for the
Cisco LRE 48 POTS Splitter
November 2002
This installation note provides instructions for installing the Cisco LRE 48 POTS Splitter with the
Catalyst Series of Long-Reach Ethernet (LRE) switches. (POTS is also known as plain old telephone
service.)
The Cisco LRE 48 POTS Splitter, also referred to as the splitter, is a set of filters that is used in installations
where LRE traffic shares the same telephone lines as existing voice, integrated services digital network
(ISDN), or Smart Phone services. The splitter separates the LRE traffic from the other telephone
services, sending the high-frequency LRE traffic to a Catalyst LRE switch and the low-frequency
telephone services to a private branch exchange (PBX) switch.
Note
Installation of a POTS splitter is only necessary if voice and data services share the same wire pair.
No configuration of the splitter is necessary. After connecting the devices to the splitter, the splitter
automatically separates the LRE and telephone traffic.
Caution
The Cisco LRE 48 POTS Splitter is a nonhomologated splitter that is not certified for connection to a
public switched telephone network (PSTN). Connecting the splitter directly to a PSTN can damage the
splitter and possibly any other equipment connected to it, such as LRE switches or LRE customer
premises equipment (CPE) devices. If telephone services will be sent directly to a PSTN, you must use
a homologated POTS splitter. Verify the regulations in your area or country regarding direct connections
to a PSTN. For more information about homologated POTS splitters, contact your Cisco sales
representative.
Corporate Headquarters:
Cisco Systems, Inc., 170 West Tasman Drive, San Jose, CA 95134-1706 USA
Copyright © 2002. Cisco Systems, Inc. All rights reserved.
Contents
Contents
This document has the following sections:
•
“Cisco Limited Lifetime Hardware Warranty Terms” section on page 2
•
“Conventions” section on page 3
•
“Description” section on page 5
•
“Installation” section on page 8
•
“Troubleshooting” section on page 21
•
“Technical Specifications” section on page 21
•
“Connectors and Cables” section on page 22
•
“Translated Warnings” section on page 24
•
“Obtaining Documentation” section on page 28
•
“Obtaining Technical Assistance” section on page 29
Cisco Limited Lifetime Hardware Warranty Terms
There are special terms applicable to your hardware warranty as well as services you may use during the
warranty period. Your formal Warranty Statement, including the warranty applicable to Cisco software,
appears in the CD which accompanies your Cisco Product. Follow these steps to access and download
the Cisco Information Packet and your warranty document from the CD or from Cisco.com.
1.
Launch your browser and go to the following URL:
http://www.cisco.com/univercd/cc/td/doc/es_inpck/cetrans.htm
The Warranties and License Agreement page appears.
2.
To view the Cisco Information Packet, perform these steps:
a. Click the Information Packet Number field and make sure that the part number 78-5235-02E0
is highlighted.
b. Select the language to view the document.
c. Click Go. The Information Packet page appears.
d. From this page you can review the document online or click the PDF icon to download and print
the document in Adobe Portable Document Format (PDF).
Note
3.
You must have Adobe Acrobat Reader in order to view and print a PDF file. If you do
not have the viewer, click the Get Acrobat Reader icon at the bottom of the page to go
to the Adobe.com website and download the reader.
To view translated and/or localized warranty information about your product, follow these steps:
a. Enter the following part number in the Warranty Document Number field:
78-6310-02C0
b. Select the language to view the document.
c. Click Go. The Cisco Warranty page appears.
Installation and Warranty Notes for the Cisco LRE 48 POTS Splitter
2
78-12550-05
Conventions
From this page you can review the document online or click the PDF icon to download and print the
document in Adobe Portable Document Format (PDF).
You may also contact our Service and Support website for assistance at:
http://www.cisco.com/public/Support_root.shtml.
Duration of Hardware Warranty
As long as the original End User continues to own or use the Product, provided that: fan and power
supply warranty is limited to five (5) years. In the event of discontinuance of product manufacture, Cisco
warranty support is limited to five (5) years from the announcement of discontinuance.
Replacement, Repair or Refund Procedure for Hardware
Cisco or its service center will use commercially reasonable efforts to ship a replacement part within ten
(10) working days after receipt of the RMA request. Actual delivery times may vary depending on
Customer location.
Cisco reserves the right to refund the purchase price as its exclusive warranty remedy.
To Receive a Return Materials Authorization (RMA) Number
Please contact the party from whom you purchased the product. If you purchased the product directly
from Cisco, contact your Cisco Sales and Service Representative.
Complete the information below and keep for ready reference.
Product purchased from:
Their telephone number:
Product Model and Serial number:
Maintenance Contract number:
Conventions
This document uses these conventions and symbols for notes, cautions, and warnings:
Note
Caution
Means reader take note. Notes contain helpful suggestions or references to materials not contained in
this manual
Means reader be careful. In this situation, you might do something that could result in equipment
damage or loss of data.
Installation and Warranty Notes for the Cisco LRE 48 POTS Splitter
78-12550-05
3
Conventions
Warning
Waarschuwing
Varoitus
This warning symbol means danger. You are in a situation that could cause bodily
injury. Before you work on any equipment, be aware of the hazards involved with
electrical circuitry and be familiar with standard practices for preventing accidents.
Dit waarschuwingssymbool betekent gevaar. U verkeert in een situatie die lichamelijk
letsel kan veroorzaken. Voordat u aan enige apparatuur gaat werken, dient u zich
bewust te zijn van de bij elektrische schakelingen betrokken risico’s en dient u op de
hoogte te zijn van standaard maatregelen om ongelukken te voorkomen.
Tämä varoitusmerkki merkitsee vaaraa. Olet tilanteessa, joka voi johtaa
ruumiinvammaan. Ennen kuin työskentelet minkään laitteiston parissa, ota selvää
sähkökytkentöihin liittyvistä vaaroista ja tavanomaisista onnettomuuksien
ehkäisykeinoista.
Attention
Ce symbole d’avertissement indique un danger. Vous vous trouvez dans une situation
pouvant entraîner des blessures. Avant d’accéder à cet équipement, soyez conscient
des dangers posés par les circuits électriques et familiarisez-vous avec les
procédures courantes de prévention des accidents.
Warnung
Dieses Warnsymbol bedeutet Gefahr. Sie befinden sich in einer Situation, die zu einer
Körperverletzung führen könnte. Bevor Sie mit der Arbeit an irgendeinem Gerät
beginnen, seien Sie sich der mit elektrischen Stromkreisen verbundenen Gefahren und
der Standardpraktiken zur Vermeidung von Unfällen bewußt.
Avvertenza
Questo simbolo di avvertenza indica un pericolo. Si è in una situazione che può
causare infortuni. Prima di lavorare su qualsiasi apparecchiatura, occorre conoscere
i pericoli relativi ai circuiti elettrici ed essere al corrente delle pratiche standard per
la prevenzione di incidenti.
Advarsel
Dette varselsymbolet betyr fare. Du befinner deg i en situasjon som kan føre til
personskade. Før du utfører arbeid på utstyr, må du være oppmerksom på de
faremomentene som elektriske kretser innebærer, samt gjøre deg kjent med vanlig
praksis når det gjelder å unngå ulykker.
Aviso
Este símbolo de aviso indica perigo. Encontra-se numa situação que lhe poderá causar
danos fisicos. Antes de começar a trabalhar com qualquer equipamento, familiarize-se
com os perigos relacionados com circuitos eléctricos, e com quaisquer práticas
comuns que possam prevenir possíveis acidentes.
¡Advertencia!
Este símbolo de aviso significa peligro. Existe riesgo para su integridad física. Antes
de manipular cualquier equipo, considerar los riesgos que entraña la corriente
eléctrica y familiarizarse con los procedimientos estándar de prevención de
accidentes.
Varning!
Denna varningssymbol signalerar fara. Du befinner dig i en situation som kan leda till
personskada. Innan du utför arbete på någon utrustning måste du vara medveten om
farorna med elkretsar och känna till vanligt förfarande för att förebygga skador.
Installation and Warranty Notes for the Cisco LRE 48 POTS Splitter
4
78-12550-05
Description
Description
The Cisco LRE 48 POTS Splitter is a passive unit and does not require any power input. It provides the
separation of the LRE high-frequency signals and the low-frequency signals of the other telephone
services on the same telephone line. The splitter has these features:
Note
•
Supports 48 lines carrying LRE traffic and telephone services
•
Allows voice- and ISDN-band signals to pass through without interference from LRE data traffic
•
Isolates the very-high-data-rate digital subscriber line (VDSL)-based signals used to carry LRE
traffic from other telephone services
•
Provides six RJ-21 connectors to connect to up to two LRE switches (12 or 24 LRE ports each), a
PBX switch (48 ports maximum), and up to 48 Cisco LRE CPE devices
Cisco LRE products are designed to share lines with analog, ISDN, and digital private branch exchange
(PBX) switch telephones that use the 0 to 700 kHz frequency range. Digital telephones connected to
digital PBX switches that use frequencies above 700 kHz do not work when sharing a line with LRE
signals. Due to the proprietary nature of digital PBX switches, some digital PBX switch services use
frequencies above 700 kHz.
Figure 1 shows the Catalyst series of LRE switches that can attach to the splitter.
Supported Catalyst LRE Switches
Version Number
Description
WS-C2912-LRE-XL
4 fixed autosensing 10/100 ports
12 LRE ports
WS-C2924-LRE-XL
WS-C2950T-8-LRE
Switch
INPUT
PWR
OUTPUT
PWR
RESET
WS-C2950T-24-LRE 24 LRE ports
2 Small Form Factor Pluggable
(SFP) module slots
2 fixed autosensing 10/100/1000
ports
10X
11X
FAN
4 fixed autosensing 10/100 ports
24 LRE ports
8 LRE ports
2 Small Form Factor Pluggable
(SFP) module slots
2 fixed autosensing 10/100/1000
ports
9X
TEMP
12X
Cisco RPS
300
Cisco RPS
300
INPUT
PWR
OUTPUT
PWR
RESET
9X
TEMP
10X
11X
FAN
1
2
3
4
SYST
RPS
RATING
100-127/200-24
1.0A/0.5A
5
12X
6
CONSOLE
7
8
STAT
0V~
50-60HZ
SPEED
MODE
Catalyst
2950 SERIES
LRE
1A
2A
1B
2B
1
SYST
RPS
RATING
100-127/200-24
1.0A/0.5A
CONSOLE
2
3
4
5
6
7
8
9
10 11
12
STAT
0V~
50-60HZ
SPEED
MODE
13 14
15 16
17 18
19 20
21 22
23 24
Catalyst
2950 SERIES
LRE
1A
2A
81734
Figure 1
1B
2B
Installation and Warranty Notes for the Cisco LRE 48 POTS Splitter
78-12550-05
5
Description
In a typical installation, the splitter is attached to one or two LRE switches, the PBX switch, and a patch
panel or wiring bundle connecting to several Cisco LRE CPE devices that are installed in rooms of a
multidwelling tenant building. Figure 2 shows an example of an installation with 1 LRE switch, 12 LRE
CPE devices, and the splitter.
Figure 2
LRE Installation Example
Cisco 575 LRE
CPE
CPEs
installed in separate
building units
POTS
Telephone
Up to 4921 feet
(1500 meters)
existing
telephone wire
CPE
CPE
CPE
CPE
CPE
CPE
CPE
CPE
CPE
CPE
CPE
CPE
Internet
router
Cisco
LRE 48 POTS
Splitter
Management
gateway
Catalyst LRE
switch
PSTN
PBX
50148
Internet
Note
Digital telephones connected to digital PBX switches that use frequencies above 700 kHz do not work
when sharing a line with LRE signals. [CSCdu73260]
Note
If the building does not use a PBX switch and telephone services are sent directly to an outside PSTN,
you need to provide a homologated POTS splitter instead of the Cisco LRE 48 POTS Splitter. For more
information about homologated POTS splitters, contact your Cisco sales representative.
The splitter has 48 internal ports and, through 6 RJ-21 connectors, connects to the LRE switches, the
PBX switch, and a patch panel or wiring bundle. Two RJ-21 connectors on the front of the splitter
connect to the LRE switches. Figure 3 shows the front panel of the splitter.
Installation and Warranty Notes for the Cisco LRE 48 POTS Splitter
6
78-12550-05
Description
Figure 3
Front Panel
LRE A
LRE B
SPLIT
TER
Connectors to
LRE switches
51283
Cisco LR
E 48
P OT S
Table 1 lists the front-panel connectors and their functions.
Table 1
Front-Panel Connectors
Port
Function
LRE A
Connects ports 1 through 24 to an LRE switch
LRE B
Connects ports 25 through 48 to an LRE switch
Four RJ-21 connectors on the rear of the splitter connect to the PBX switch and the patch panel or wiring
bundle. Figure 4 shows the rear panel of the splitter.
Figure 4
Rear Panel
Connectors to
patch panel
LINE B
PBX B
LINE A
51979
PBX A
Connectors to
PBX switch
Table 2 lists the rear-panel connectors and their functions.
Table 2
Rear-Panel Connectors
Port
Function
LINE A
Connects ports 1 through 24 to a patch panel connecting up to 24
LRE CPE devices. These CPE devices are controlled by the LRE
switch attached to the LRE A connector on the front of the splitter.
PBX A
Connects ports 1 through 24 to a PBX switch that supplies the other
telephone services through the LRE CPE devices connected to
LINE A.
Installation and Warranty Notes for the Cisco LRE 48 POTS Splitter
78-12550-05
7
Installation
Table 2
Rear-Panel Connectors (continued)
Port
Function
LINE B
Connects ports 25 through 48 to a patch panel connecting up to 24
LRE CPE devices. These CPE devices are controlled by the LRE
switch attached to the LRE B connector on the front of the splitter.
PBX B
Connects ports 25 through 48 to a PBX switch that supplies the
other telephone services through the LRE CPE devices connected to
LINE B.
Installation
This section describes how to install the splitter.
EMC Regulatory Statements
U.S.A.
U.S. regulatory information for this product is at the back of this document.
Taiwan
Hungary
This equipment is a class A product and should be used and installed properly according to the Hungarian
EMC Class A requirements (MSZEN55022). Class A equipment is designed for typical commercial establishments for which special conditions of installation and protection distance are used.
Figyelmeztetés a felhasználói kézikönyv számára:
Ez a berendezés “A” osztályú termék, felhasználására és üzembe helyezésére a magyar EMC “A” osztályú követelményeknek (MSZ EN 55022) megfeleloen kerülhet sor, illetve ezen “A” osztályú berendezések csak megfelelo kereskedelmi forrásból származhatnak, amelyek biztosítják a megfelelo
speciális üzembe helyezési körülményeket és biztonságos üzemelési távolságok alkalmazását.
Installation and Warranty Notes for the Cisco LRE 48 POTS Splitter
8
78-12550-05
Installation Guidelines
Package Contents
•
Cisco LRE 48 POTS Splitter
•
Installation and Warranty Notes for the Cisco LRE 48 POTS Splitter
•
Mounting kit containing these items:
– Four rubber feet for mounting the splitter on a table, shelf, or desk
– Two rack-mounting brackets
– Four number-8 Phillips flat-head screws for attaching the brackets to the splitter (19-inch rack
mount)
– Four number-8 Phillips truss-head screws for attaching the brackets to the splitter (23- or
24-inch rack mount)
– Four number-12 Phillips machine screws for attaching the brackets to a rack
Installation Guidelines
The splitter can be installed on a desk, in a rack, or on a wall.
Note
To mount the splitter on a wall, you need two special wall-mount brackets (Cisco part number
wallmount-1ru=). To order these brackets, contact your Cisco sales representative.
Note
Wall-mounting is only recommended for installations with one splitter and one LRE switch. If you will
be connecting two LRE switches to the splitter, we recommend mounting the components in a rack. (See
the “Installing the Splitter in a Rack” section on page 10.)
Installing the Splitter on a Table or Shelf
Follow these steps to install the splitter on a table or shelf:
Step 1
Locate the adhesive strip with the rubber feet in the mounting-kit envelope.
Step 2
Attach the four rubber feet to the recessed areas on the bottom of the unit.
Step 3
Place the splitter on the table or shelf.
Installation and Warranty Notes for the Cisco LRE 48 POTS Splitter
78-12550-05
9
Installation Guidelines
Installing the Splitter in a Rack
Warning
To prevent bodily injury when mounting or servicing this unit in a rack, you must take special
precautions to ensure that the system remains stable. The following guidelines are provided to ensure
your safety
•
If the rack is provided with stabilizing devices, install the stabilizers before mounting or servicing
the unit in the rack.
•
When mounting this unit in a partially filled rack, load the rack from the bottom to the top with the
heaviest component at the bottom of the rack.
•
If the rack is provided with stabilizing devices, install the stabilizers before mounting or servicing
the unit in the rack.
The supplied rack-mounting brackets can be attached to a 19-, 23-, or 24-inch rack. Figure 5 shows
which mounting holes to use.
Bracket Mounting Points
19" rack
mount point
24" rack
mount point
23" rack
mount point
19" rack
mount point
24" rack
mount point
23" rack
mount point
54725
Figure 5
To install the splitter in a 19-, 23-, or 24-inch standard rack, follow these instructions:
•
Attaching the brackets to the splitter
•
Mounting the splitter in a rack
Attaching the Brackets to the Splitter
The bracket orientation and screws that you use depend on whether you are attaching the brackets for a
19-, 23-, or 24-inch rack. Use two of the supplied screws to attach each bracket, according to the rack
size:
•
For a 19-inch rack, use the supplied Phillips flat-head screws to attach the long side of the bracket
to the splitter.
•
For a 23- or 24-inch rack, use the supplied Phillips truss-head screws to attach the short side of the
bracket to the splitter.
Installation and Warranty Notes for the Cisco LRE 48 POTS Splitter
10
78-12550-05
Installation Guidelines
Figure 6 shows how to attach a bracket to one side of the splitter. Follow the same steps to attach the
second bracket to the opposite side of the splitter.
Figure 6
Attaching Brackets to the Splitter
LRE B
Cisco L
P OT S
RE 48
S P L IT
TER
19" Configuration
Phillips
flat-head
screws
LRE B
Cisco L
P OT S
RE 48
S P L IT
TER
Phillips
truss-head
screws
51293
23" and 24" configuration
Installation and Warranty Notes for the Cisco LRE 48 POTS Splitter
78-12550-05
11
Installation Guidelines
Mounting the Splitter in a Rack
After the brackets are attached to the splitter, use the four supplied Phillips machine screws to securely
attach the brackets to the rack, as shown in Figure 7.
Figure 7
Mounting the Splitter in a Rack
LRE A
LRE B
Cisco LR
E 48
PO
ER
51294
TS SP LI
TT
Phillips machine screws
The splitter can be mounted above or below an LRE switch. Figure 8 shows the splitter mounted below
an LRE switch.
Figure 8
Mounting the Splitter in a Rack Under an LRE Switch
INPUT
PWR
OUTPUT
PWR
RESET
TEMP
FAN
9X
10X
11X
12X
Catalyst
2900
LRE XL
LRE A
LRE B
Cisco LR
E 48
SP LIT
TE R
51281
POTS
If the splitter will be connected to two LRE switches, we recommend mounting the splitter between the
two switches. (See Figure 9.)
Installation and Warranty Notes for the Cisco LRE 48 POTS Splitter
12
78-12550-05
Cabling Recommendations
Figure 9
Mounting the Splitter in a Rack Between Two LRE Switches
INPUT
PWR
OUTPUT
PWR
RESET
TEMP
9X
10X
FAN
11X
12X
Catalyst
2900
LRE XL
LRE A
LRE B
Cisco LR
POTS
E 48
SP LIT
TE R
INPUT
PWR
OUTPUT
PWR
RESET
TEMP
FAN
9X
10X
11X
12X
LRE XL
51280
Catalyst
2900
Cabling Recommendations
Connecting the splitter to a switch or patch panel requires a male-to-male RJ-21 cable, Category 3 or
above.You can order RJ-21 cables from your cable vendor, or you can order these cables from your Cisco
sales representative:
•
CAB-5-M120M120-5= (Category 5 cable with 90-degree, male-to-male RJ-21 connectors)
•
CAB-5-M180M120-5= (Category 5 cable with 120-degree, male-to-male RJ-21 connectors)
The screws that you need to secure the cable to the switch are shipped with the cable. Contact your Cisco
sales representative for more information.
Note
If you order cables from your cable vendor or decide to make cables yourself, refer to the “Connectors
and Cables” section on page 22.
Facing Cables in the Same Direction
If you decide to use cables that have 120-degree RJ-21 connectors, you need to decide whether the cables
face to the right, to the left, or from the middle of the splitter before you order them. (See Figure 10 and
Figure 11.) Some cables have large connectors and a thick coating around the cable. If they are not
installed in the same direction, they do not fit easily on the splitter connectors.
Installation and Warranty Notes for the Cisco LRE 48 POTS Splitter
78-12550-05
13
Cabling Recommendations
Figure 10
Connecting the Wiring Trunk Cables (Front View)
LRE A
LRE B
Cisco LR
E 48
PO
TS SP LI
TT
ER
Either both cables are
routed to the right.
LRE A
LRE B
Cisco LR
E 48
PO
TS SP LI
TT
ER
54657
Or both cables are
routed to the left.
Installation and Warranty Notes for the Cisco LRE 48 POTS Splitter
14
78-12550-05
Cabling Recommendations
Figure 11
Connecting the Wiring Trunk Cables (Rear View)
LINE B
PBX B
LINE A
PBX A
Either cables are
routed on the right.
LINE B
PBX B
LINE A
PBX A
Or cables are
routed on the left.
LINE B
PBX B
LINE A
Or cables are divided between
the left and right.
54730
PBX A
Securing Cables
Each cable must be secured to the splitter by one of the following methods:
•
For a 90-degree connector, use two screws. (See the top of Figure 12.)
•
For a 120-degree connector, use a screw and a cable tie. (See the bottom of Figure 12.)
Note
The cable tie is not included with the connector and cable assembly.
Installation and Warranty Notes for the Cisco LRE 48 POTS Splitter
78-12550-05
15
Cabling Recommendations
Figure 12
Securing a Cable to the Splitter
LRE A
Screw
Screw
RJ-21
connector
Cable to
wiring trunk
LRE A
RJ-21
connector
Cable to
wiring trunk
0.20 inch
(5 mm)
Cable tie
54656
Screw
Installation and Warranty Notes for the Cisco LRE 48 POTS Splitter
16
78-12550-05
Connecting to LRE A, PBX A, and LINE A
Connecting to LRE A, PBX A, and LINE A
Ports 1 through 24 of the splitter connect to the LRE A, PBX A, and LINE A connectors. To connect
these ports to a Catalyst LRE switch, PBX switch, and patch panel, follow these steps:
Step 1
Connect one end of a wiring trunk cable (not included) to the LRE A connector on the front of the
splitter. (See Figure 13.)
Figure 13
Connecting LRE A to an LRE Switch
INPUT
PWR
OUTPUT
PWR
RESET
9X
TEMP
FAN
10X
11X
12X
Catalyst
2900
LRE XL
LRE A
LRE B
Cisco LR
E 48
SP LIT
TE R
51983
POTS
Step 2
Connect the other end of the wiring trunk cable to the LRE port on the front of the LRE switch.
Step 3
Connect one end of another wiring trunk cable (not included) to the PBX A connector on the rear of the
splitter. (See Figure 14.)
Figure 14
Connecting PBX A to a PBX Switch
LINE B
PBX B
LINE A
PBX A
5-3A
50/60Hz
~
DC OUT
PUT
1
CONSOL
E
53025
100-240V
To PBX
Step 4
Connect the other end of the wiring trunk cable to the PBX switch.
Step 5
Connect one end of another wiring trunk cable (not included) to the LINE A connector on the rear of
the splitter. (See Figure 15.)
Installation and Warranty Notes for the Cisco LRE 48 POTS Splitter
78-12550-05
17
Connecting to LRE A, PBX A, and LINE A
Figure 15
Connecting LINE A to a Patch Panel
LINE B
PBX B
LINE A
PBX A
5-3A
50/60Hz
~
DC OUT
PUT
1
CONSOL
E
To
patch
panel
Step 6
53027
100-240V
To PBX
Connect the other end of the wiring trunk cable to the patch panel or wiring bundle that connects the
LRE CPE devices 1 through 24.
You do not need to configure the splitter. The splitter now separates the high-frequency LRE data from
the low-frequency telephone services on ports 1 through 24, sending the LRE traffic to the LRE switch
and the other telephone services to the PBX switch.
Installation and Warranty Notes for the Cisco LRE 48 POTS Splitter
18
78-12550-05
Connecting to LRE B, PBX B, and LINE B
Connecting to LRE B, PBX B, and LINE B
Ports 25 through 48 of the splitter are connected to the LRE B, PBX B, and LINE B connectors. To
connect these ports to an LRE switch, PBX switch, and patch panel, follow these steps:
Step 1
Connect one end of a wiring trunk cable (not included) to the LRE B connector on the front of the
splitter. (See Figure 16.)
Figure 16
Connecting LRE B to an LRE Switch
INPUT
PWR
OUTPUT
PWR
RESET
TEMP
9X
10X
FAN
11X
12X
Catalyst
2900
LRE XL
LRE A
LRE B
Cisco LR
POTS
E 48
SP LIT
TE R
INPUT
PWR
OUTPUT
PWR
RESET
TEMP
FAN
9X
10X
11X
12X
LRE XL
51984
Catalyst
2900
Step 2
Connect the other end of the wiring trunk cable to the LRE port on the front of the LRE switch.
Step 3
Connect one end of another wiring trunk cable (not included) to the PBX B connector on the rear panel
of the splitter. (See Figure 17.)
Installation and Warranty Notes for the Cisco LRE 48 POTS Splitter
78-12550-05
19
Connecting to LRE B, PBX B, and LINE B
Figure 17
100-240V
5-3A
50/60Hz
Connecting PBX B to a PBX Switch
~
DC OUT
PUT
1
LINE B
PBX B
CONSOL
E
LINE A
PBX A
100-240V
5-3A
50/60Hz
~
CONSOL
E
To PBX
To
patch
panel
53028
DC OUT
PUT 1
To PBX
Step 4
Connect the other end of the wiring trunk cable to the PBX switch.
Step 5
Connect one end of another wiring trunk cable (not included) to the LINE B connector on the rear of
the splitter. (See Figure 18.)
Figure 18
100-240V
5-3A
50/60Hz
Connecting LINE B to a Patch Panel
~
DC OUT
PUT 1
LINE B
PBX B
CONSOL
E
LINE A
PBX A
5-3A
50/60Hz
~
DC OUT
PUT
1
CONSOL
E
To
patch
panel
To PBX
To
patch
panel
54655
100-240V
To PBX
Installation and Warranty Notes for the Cisco LRE 48 POTS Splitter
20
78-12550-05
Troubleshooting
Step 6
Connect the other end of the wiring trunk cable to the patch panel or wiring bundle that connects the
LRE CPE devices 25 through 48.
The splitter now separates the high-frequency LRE data from the low-frequency telephone services on
ports 25 through 48, sending the LRE traffic to the LRE switch and the other telephone services to the
PBX switch.
Troubleshooting
Table 3 describes how to detect and solve a problem.
Table 3
Common Problem and Its Solution
Symptom
Possible Causes
Corrective Action
Intermittent or failed POTS
connection.
RJ-21 connectors not correctly
attached to splitter.
Secure connectors by using cable ties
and screws.
For more information about troubleshooting connections to LRE devices, refer to these documents:
•
Catalyst 2900 Series XL Hardware Installation Guide
•
Catalyst 2950 Desktop Switch Hardware Installation Guide
•
Cisco LRE CPE Hardware Installation Guide
Technical Specifications
Table 4 and Table 5 list the technical specifications and agency approvals.
Table 4
Technical Specifications
Environmental Ranges
Operating temperature
32 to 113°F (0 to 45°C)
Storage temperature
–4 to 149°F (–10 to 65°C)
Operating humidity
10 to 85% (noncondensing)
Storage humidity
5 to 95% (noncondensing)
Operating altitude
Up to 10,000 ft (3000 m)
Storage altitude
Up to 15,000 ft (4570 m)
Power Consumption
0W
Note
Impedance
The Cisco LRE 48 POTS Splitter is a
passive device. It has no power
requirements.
150 ohms
Physical Dimensions
Installation and Warranty Notes for the Cisco LRE 48 POTS Splitter
78-12550-05
21
Connectors and Cables
Table 4
Technical Specifications (continued)
Environmental Ranges
Dimensions (H x W x D)
1.73 x 17.5 x 13.5 in.
(4.4 x 44.5 x 34.2 cm)
Weight
9 lb (4 kg)
Table 5
Agency Approvals
EMC
FCC Part 15 Class A
EN 55022B Class A (CISPR22 Class A)
VCCI Class I
BSMI
CE
Connectors and Cables
The Cisco LRE 48 POTS Splitter has six RJ-21 connectors. Each connector has 50 pins. (See Figure 3
and Figure 4.) One cable (not included) is required for each connection. Table 6 and Table 7 list the
pinouts.
Table 6
RJ-21 Cable Pinouts for LRE A, LINE A, and PBX A
Pins
Circuit
Pins
Circuits
1, 26
1, tip/ring
14, 39
14, tip/ring
2, 27
2, tip/ring
15, 40
15, tip/ring
3, 28
3, tip/ring
16, 41
16, tip/ring
4, 29
4, tip/ring
17, 42
17, tip/ring
5, 30
5, tip/ring
18, 43
18, tip/ring
6, 31
6, tip/ring
19, 44
19, tip/ring
7, 32
7, tip/ring
20, 45
20, tip/ring
8, 33
8, tip/ring
21, 46
21, tip/ring
9, 34
9, tip/ring
22, 47
22, tip/ring
10, 35
10, tip/ring
23, 48
23, tip/ring
11, 36
11, tip/ring
24, 49
24, tip/ring
12, 37
12, tip/ring
25, 50
No connection
13, 38
13, tip/ring
Installation and Warranty Notes for the Cisco LRE 48 POTS Splitter
22
78-12550-05
Connectors and Cables
Table 7
RJ-21 Cable Pinouts for LRE B, LINE B, and PBX B
Pins
Circuit
Pins
Circuits
1, 26
25, tip/ring
14, 39
38, tip/ring
2, 27
26, tip/ring
15, 40
39, tip/ring
3, 28
27, tip/ring
16, 41
40, tip/ring
4, 29
28, tip/ring
17, 42
41, tip/ring
5, 30
29, tip/ring
18, 43
42, tip/ring
6, 31
30, tip/ring
19, 44
43, tip/ring
7, 32
31, tip/ring
20, 45
44, tip/ring
8, 33
32, tip/ring
21, 46
45, tip/ring
9, 34
33, tip/ring
22, 47
46, tip/ring
10, 35
34, tip/ring
23, 48
47, tip/ring
11, 36
35, tip/ring
24, 49
48, tip/ring
12, 37
36, tip/ring
25, 50
No connection
13, 38
37, tip/ring
Installation and Warranty Notes for the Cisco LRE 48 POTS Splitter
78-12550-05
23
Translated Warnings
Translated Warnings
Warning
Waarschuwing
Varoitus
To prevent bodily injury when mounting or servicing this unit in a rack, you
must take special precautions to ensure that the system remains stable. The
following guidelines are provided to ensure your safety:
•
This unit should be mounted at the bottom of the rack if it is the only unit
in the rack.
•
When mounting this unit in a partially filled rack, load the rack from the
bottom to the top with the heaviest component at the bottom of the rack.
•
If the rack is provided with stabilizing devices, install the stabilizers before
mounting or servicing the unit in the rack.
Om lichamelijk letsel te voorkomen wanneer u dit toestel in een rek monteert
of het daar een servicebeurt geeft, moet u speciale voorzorgsmaatregelen
nemen om ervoor te zorgen dat het toestel stabiel blijft. De onderstaande
richtlijnen worden verstrekt om uw veiligheid te verzekeren:
•
Dit toestel dient onderaan in het rek gemonteerd te worden als het toestel
het enige in het rek is.
•
Wanneer u dit toestel in een gedeeltelijk gevuld rek monteert, dient u het rek
van onderen naar boven te laden met het zwaarste onderdeel onderaan in het
rek.
•
Als het rek voorzien is van stabiliseringshulpmiddelen, dient u de
stabilisatoren te monteren voordat u het toestel in het rek monteert of het
daar een servicebeurt geeft.
Kun laite asetetaan telineeseen tai huolletaan sen ollessa telineessä, on
noudatettava erityisiä varotoimia järjestelmän vakavuuden säilyttämiseksi,
jotta vältytään loukkaantumiselta. Noudata seuraavia turvallisuusohjeita:
•
Jos telineessä ei ole muita laitteita, aseta laite telineen alaosaan.
•
Jos laite asetetaan osaksi täytettyyn telineeseen, aloita kuormittaminen sen
alaosasta kaikkein raskaimmalla esineellä ja siirry sitten sen yläosaan.
•
Jos telinettä varten on vakaimet, asenna ne ennen laitteen asettamista
telineeseen tai sen huoltamista siinä.
Installation and Warranty Notes for the Cisco LRE 48 POTS Splitter
24
78-12550-05
Translated Warnings
Attention
Warnung
Avvertenza
Pour éviter toute blessure corporelle pendant les opérations de montage ou de
réparation de cette unité en casier, il convient de prendre des précautions
spéciales afin de maintenir la stabilité du système. Les directives ci-dessous
sont destinées à assurer la protection du personnel :
•
Si cette unité constitue la seule unité montée en casier, elle doit être placée
dans le bas.
•
Si cette unité est montée dans un casier partiellement rempli, charger le
casier de bas en haut en plaçant l'élément le plus lourd dans le bas.
•
Si le casier est équipé de dispositifs stabilisateurs, installer les stabilisateurs
avant de monter ou de réparer l'unité en casier.
Zur Vermeidung von Körperverletzung beim Anbringen oder Warten dieser
Einheit in einem Gestell müssen Sie besondere Vorkehrungen treffen, um
sicherzustellen, daß das System stabil bleibt. Die folgenden Richtlinien sollen
zur Gewährleistung Ihrer Sicherheit dienen:
•
Wenn diese Einheit die einzige im Gestell ist, sollte sie unten im Gestell
angebracht werden.
•
Bei Anbringung dieser Einheit in einem zum Teil gefüllten Gestell ist das
Gestell von unten nach oben zu laden, wobei das schwerste Bauteil unten im
Gestell anzubringen ist.
•
Wird das Gestell mit Stabilisierungszubehör geliefert, sind zuerst die
Stabilisatoren zu installieren, bevor Sie die Einheit im Gestell anbringen
oder sie warten.
Per evitare infortuni fisici durante il montaggio o la manutenzione di questa
unità in un supporto, occorre osservare speciali precauzioni per garantire che
il sistema rimanga stabile. Le seguenti direttive vengono fornite per garantire
la sicurezza personale:
•
Questa unità deve venire montata sul fondo del supporto, se si tratta
dell’unica unità da montare nel supporto.
•
Quando questa unità viene montata in un supporto parzialmente pieno,
caricare il supporto dal basso all’alto, con il componente più pesante
sistemato sul fondo del supporto.
•
Se il supporto è dotato di dispositivi stabilizzanti, installare tali dispositivi
prima di montare o di procedere alla manutenzione dell’unità nel supporto.
Installation and Warranty Notes for the Cisco LRE 48 POTS Splitter
78-12550-05
25
Translated Warnings
Advarsel
Aviso
Unngå fysiske skader under montering eller reparasjonsarbeid på denne
enheten når den befinner seg i et kabinett. Vær nøye med at systemet er stabilt.
Følgende retningslinjer er gitt for å verne om sikkerheten:
•
Denne enheten bør monteres nederst i kabinettet hvis dette er den eneste
enheten i kabinettet.
•
Ved montering av denne enheten i et kabinett som er delvis fylt, skal
kabinettet lastes fra bunnen og opp med den tyngste komponenten nederst i
kabinettet.
•
Hvis kabinettet er utstyrt med stabiliseringsutstyr, skal stabilisatorene
installeres før montering eller utføring av reparasjonsarbeid på enheten i
kabinettet.
Para se prevenir contra danos corporais ao montar ou reparar esta unidade
numa estante, deverá tomar precauções especiais para se certificar de que o
sistema possui um suporte estável. As seguintes directrizes ajudá-lo-ão a
efectuar o seu trabalho com segurança:
•
Esta unidade deverá ser montada na parte inferior da estante, caso seja esta
a única unidade a ser montada.
•
Ao montar esta unidade numa estante parcialmente ocupada, coloque os
itens mais pesados na parte inferior da estante, arrumando-os de baixo para
cima.
•
Se a estante possuir um dispositivo de estabilização, instale-o antes de
montar ou reparar a unidade.
Installation and Warranty Notes for the Cisco LRE 48 POTS Splitter
26
78-12550-05
Related Documentation
¡Advertencia!
Varning!
Para evitar lesiones durante el montaje de este equipo sobre un bastidor, o
posteriormente durante su mantenimiento, se debe poner mucho cuidado en
que el sistema quede bien estable. Para garantizar su seguridad, proceda
según las siguientes instrucciones:
•
Colocar el equipo en la parte inferior del bastidor, cuando sea la única
unidad en el mismo.
•
Cuando este equipo se vaya a instalar en un bastidor parcialmente ocupado,
comenzar la instalación desde la parte inferior hacia la superior colocando
el equipo más pesado en la parte inferior.
•
Si el bastidor dispone de dispositivos estabilizadores, instalar éstos antes de
montar o proceder al mantenimiento del equipo instalado en el bastidor.
För att undvika kroppsskada när du installerar eller utför underhållsarbete på
denna enhet på en ställning måste du vidta särskilda försiktighetsåtgärder för
att försäkra dig om att systemet står stadigt. Följande riktlinjer ges för att
trygga din säkerhet:
•
Om denna enhet är den enda enheten på ställningen skall den installeras
längst ned på ställningen.
•
Om denna enhet installeras på en delvis fylld ställning skall ställningen
fyllas nedifrån och upp, med de tyngsta enheterna längst ned på ställningen.
•
Om ställningen är försedd med stabiliseringsdon skall dessa monteras fast
innan enheten installeras eller underhålls på ställningen.
Related Documentation
You can order printed copies of documents with a DOC-xxxxxxx= number.
The following publications provide more information about products associated with the
Cisco LRE 48 POTS Splitter:
Catalyst 2900 Series XL and 3500 Series XL Switches
•
Release Notes for the Catalyst 2900 Series XL and Catalyst 3500 Series XL Switches (not orderable,
but is available on Cisco.com)
•
Catalyst 2900 XL and Catalyst 3500 XL Software Configuration Guide (order number
DOC-786511=)
•
Catalyst 2900 Series XL and Catalyst 3500 Series XL Command Reference (order number
DOC-7812155=)
•
Catalyst 2900 Series XL Hardware Installation Guide (order number DOC-786461=)
Catalyst 2950 Desktop Switches
•
Release Notes for the Catalyst 2950 Desktop Switches (not orderable, but is available on Cisco.com)
•
Catalyst 2950 Desktop Switch Software Configuration Guide (order number DOC-11380=)
•
Catalyst 2950 Desktop Switch Command Reference (order number DOC-11381=)
Installation and Warranty Notes for the Cisco LRE 48 POTS Splitter
78-12550-05
27
Obtaining Documentation
•
Catalyst 2950 Desktop Switch Hardware Installation Guide(order number DOC-11157=)
•
Installation Notes for Small-Form-Factor Pluggable Modules (order number DOC-7815160=)
Cisco LRE CPE
•
Cisco LRE CPE Hardware Installation Guide (order number DOC-7811469=)
Obtaining Documentation
The following sections provide sources for obtaining documentation from Cisco Systems.
World Wide Web
You can access the most current Cisco documentation on the World Wide Web at the following sites:
•
http://www.cisco.com
•
http://www-china.cisco.com
•
http://www-europe.cisco.com
Documentation CD-ROM
Cisco documentation and additional literature are available in a CD-ROM package, which ships
with your product. The Documentation CD-ROM is updated monthly and may be more current than
printed documentation. The CD-ROM package is available as a single unit or as an annual subscription.
Ordering Documentation
Cisco documentation is available in the following ways:
•
Registered Cisco Direct Customers can order Cisco Product documentation from the Networking
Products MarketPlace:
http://www.cisco.com/cgi-bin/order/order_root.pl
•
Registered Cisco.com users can order the Documentation CD-ROM through the online Subscription
Store:
http://www.cisco.com/go/subscription
•
Nonregistered CCO users can order documentation through a local account representative by calling
Cisco corporate headquarters (California, USA) at 408 526-7208 or, in North America, by calling
800 553-NETS(6387).
Documentation Feedback
If you are reading Cisco product documentation on the World Wide Web, you can submit technical
comments electronically. Click Feedback in the toolbar and select Documentation. After you complete
the form, click Submit to send it to Cisco.
Installation and Warranty Notes for the Cisco LRE 48 POTS Splitter
28
78-12550-05
Obtaining Technical Assistance
You can e-mail your comments to [email protected].
To submit your comments by mail, for your convenience many documents contain a response card
behind the front cover. Otherwise, you can mail your comments to the following address:
Cisco Systems, Inc.
Document Resource Connection
170 West Tasman Drive
San Jose, CA 95134-9883
We appreciate your comments.
Obtaining Technical Assistance
Cisco provides Cisco.com as a starting point for all technical assistance. Customers and partners can
obtain documentation, troubleshooting tips, and sample configurations from online tools by using the
Cisco Technical Assistance Center (TAC) Web Site. Cisco.com registered users have complete access to
the technical support resources on the Cisco TAC Web Site.
Cisco.com
Cisco.com is the foundation of a suite of interactive, networked services that provides immediate, open
access to Cisco information, networking solutions, services, programs, and resources at any time, from
anywhere in the world.
Cisco.com is a highly integrated Internet application and a powerful, easy-to-use tool that provides a
broad range of features and services to help you to
•
Streamline business processes and improve productivity
•
Resolve technical issues with online support
•
Download and test software packages
•
Order Cisco learning materials and merchandise
•
Register for online skill assessment, training, and certification programs
You can self-register on Cisco.com to obtain customized information and service. To access Cisco.com,
go to the following URL:
http://www.cisco.com
Technical Assistance Center
The Cisco TAC is available to all customers who need technical assistance with a Cisco product,
technology, or solution. Two types of support are available through the Cisco TAC: the Cisco TAC
Web Site and the Cisco TAC Escalation Center.
Inquiries to Cisco TAC are categorized according to the urgency of the issue:
•
Priority level 4 (P4)—You need information or assistance concerning Cisco product capabilities,
product installation, or basic product configuration.
•
Priority level 3 (P3)—Your network performance is degraded. Network functionality is noticeably
impaired, but most business operations continue.
Installation and Warranty Notes for the Cisco LRE 48 POTS Splitter
78-12550-05
29
Obtaining Technical Assistance
•
Priority level 2 (P2)—Your production network is severely degraded, affecting significant aspects
of business operations. No workaround is available.
•
Priority level 1 (P1)—Your production network is down, and a critical impact to business operations
will occur if service is not restored quickly. No workaround is available.
Which Cisco TAC resource you choose is based on the priority of the problem and the conditions of
service contracts, when applicable.
Cisco TAC Web Site
The Cisco TAC Web Site allows you to resolve P3 and P4 issues yourself, saving both cost and time. The
site provides around-the-clock access to online tools, knowledge bases, and software. To access the
Cisco TAC Web Site, go to the following URL:
http://www.cisco.com/tac
All customers, partners, and resellers who have a valid Cisco services contract have complete access to
the technical support resources on the Cisco TAC Web Site. The Cisco TAC Web Site requires a
Cisco.com login ID and password. If you have a valid service contract but do not have a login ID or
password, go to the following URL to register:
http://www.cisco.com/register/
If you cannot resolve your technical issues by using the Cisco TAC Web Site, and you are a Cisco.com
registered user, you can open a case online by using the TAC Case Open tool at the following URL:
http://www.cisco.com/tac/caseopen
If you have Internet access, it is recommended that you open P3 and P4 cases through the Cisco TAC
Web Site.
Cisco TAC Escalation Center
The Cisco TAC Escalation Center addresses issues that are classified as priority level 1 or priority
level 2; these classifications are assigned when severe network degradation significantly impacts
business operations. When you contact the TAC Escalation Center with a P1 or P2 problem, a Cisco TAC
engineer will automatically open a case.
To obtain a directory of toll-free Cisco TAC telephone numbers for your country, go to the following
URL:
http://www.cisco.com/warp/public/687/Directory/DirTAC.shtml
Before calling, please check with your network operations center to determine the level of Cisco support
services to which your company is entitled; for example, SMARTnet, SMARTnet Onsite, or Network
Supported Accounts (NSA). In addition, please have available your service agreement number and your
product serial number.
THE SPECIFICATIONS AND INFORMATION REGARDING THE PRODUCTS IN THIS MANUAL ARE SUBJECT TO CHANGE WITHOUT
NOTICE. ALL STATEMENTS, INFORMATION, AND RECOMMENDATIONS IN THIS MANUAL ARE BELIEVED TO BE ACCURATE BUT
ARE PRESENTED WITHOUT WARRANTY OF ANY KIND, EXPRESS OR IMPLIED. USERS MUST TAKE FULL RESPONSIBILITY FOR
THEIR APPLICATION OF ANY PRODUCTS.
THE SOFTWARE LICENSE AND LIMITED WARRANTY FOR THE ACCOMPANYING PRODUCT ARE SET FORTH IN THE INFORMATION
PACKET THAT SHIPPED WITH THE PRODUCT AND ARE INCORPORATED HEREIN BY THIS REFERENCE. IF YOU ARE UNABLE TO
LOCATE THE SOFTWARE LICENSE OR LIMITED WARRANTY, CONTACT YOUR CISCO REPRESENTATIVE FOR A COPY.
The following information is for FCC compliance of Class A devices: This equipment has been tested and found to comply with the limits for a Class
A digital device, pursuant to part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference when
the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio-frequency energy and, if not installed
and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a
residential area is likely to cause harmful interference, in which case users will be required to correct the interference at their own expense.
Installation and Warranty Notes for the Cisco LRE 48 POTS Splitter
30
78-12550-05
Obtaining Technical Assistance
The following information is for FCC compliance of Class B devices: The equipment described in this manual generates and may radiate
radio-frequency energy. If it is not installed in accordance with Cisco’s installation instructions, it may cause interference with radio and television
reception. This equipment has been tested and found to comply with the limits for a Class B digital device in accordance with the specifications in
part 15 of the FCC rules. These specifications are designed to provide reasonable protection against such interference in a residential installation.
However, there is no guarantee that interference will not occur in a particular installation.
Modifying the equipment without Cisco’s written authorization may result in the equipment no longer complying with FCC requirements for Class
A or Class B digital devices. In that event, your right to use the equipment may be limited by FCC regulations, and you may be required to correct
any interference to radio or television communications at your own expense.
You can determine whether your equipment is causing interference by turning it off. If the interference stops, it was probably caused by the Cisco
equipment or one of its peripheral devices. If the equipment causes interference to radio or television reception, try to correct the interference by
using one or more of the following measures:
• Turn the television or radio antenna until the interference stops.
• Move the equipment to one side or the other of the television or radio.
• Move the equipment farther away from the television or radio.
• Plug the equipment into an outlet that is on a different circuit from the television or radio. (That is, make certain the equipment and the television
or radio are on circuits controlled by different circuit breakers or fuses.)
Modifications to this product not authorized by Cisco Systems, Inc. could void the FCC approval and negate your authority to operate the product.
The Cisco implementation of TCP header compression is an adaptation of a program developed by the University of California, Berkeley (UCB) as
part of UCB’s public domain version of the UNIX operating system. All rights reserved. Copyright © 1981, Regents of the University of California.
NOTWITHSTANDING ANY OTHER WARRANTY HEREIN, ALL DOCUMENT FILES AND SOFTWARE OF THESE SUPPLIERS ARE
PROVIDED “AS IS” WITH ALL FAULTS. CISCO AND THE ABOVE-NAMED SUPPLIERS DISCLAIM ALL WARRANTIES, EXPRESSED
OR IMPLIED, INCLUDING, WITHOUT LIMITATION, THOSE OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE AND
NONINFRINGEMENT OR ARISING FROM A COURSE OF DEALING, USAGE, OR TRADE PRACTICE.
IN NO EVENT SHALL CISCO OR ITS SUPPLIERS BE LIABLE FOR ANY INDIRECT, SPECIAL, CONSEQUENTIAL, OR INCIDENTAL
DAMAGES, INCLUDING, WITHOUT LIMITATION, LOST PROFITS OR LOSS OR DAMAGE TO DATA ARISING OUT OF THE USE OR
INABILITY TO USE THIS MANUAL, EVEN IF CISCO OR ITS SUPPLIERS HAVE BEEN ADVISED OF THE POSSIBILITY OF SUCH
DAMAGES.
CCVP, the Cisco logo, and the Cisco Square Bridge logo are trademarks of Cisco Systems, Inc.; Changing the Way We Work, Live, Play, and Learn is a
service mark of Cisco Systems, Inc.; and Access Registrar, Aironet, BPX, Catalyst, CCDA, CCDP, CCIE, CCIP, CCNA, CCNP, CCSP, Cisco, the Cisco
Certified Internetwork Expert logo, Cisco IOS, Cisco Press, Cisco Systems, Cisco Systems Capital, the Cisco Systems logo, Cisco Unity,
Enterprise/Solver, EtherChannel, EtherFast, EtherSwitch, Fast Step, Follow Me Browsing, FormShare, GigaDrive, HomeLink, Internet Quotient, IOS,
iPhone, IP/TV, iQ Expertise, the iQ logo, iQ Net Readiness Scorecard, iQuick Study, LightStream, Linksys, MeetingPlace, MGX, Networking Academy,
Network Registrar, Packet, PIX, ProConnect, ScriptShare, SMARTnet, StackWise, The Fastest Way to Increase Your Internet Quotient, and TransPath are
registered trademarks of Cisco Systems, Inc. and/or its affiliates in the United States and certain other countries.
All other trademarks mentioned in this document or Website are the property of their respective owners. The use of the word partner does not imply a
partnership relationship between Cisco and any other company. (0705R)
Installation and Warranty Notes for the Cisco LRE 48 POTS Splitter
Copyright © 2001–2002, Cisco Systems, Inc.
All rights reserved.
Installation and Warranty Notes for the Cisco LRE 48 POTS Splitter
78-12550-05
31
Obtaining Technical Assistance
Installation and Warranty Notes for the Cisco LRE 48 POTS Splitter
32
78-12550-05