Collecting units Range of enclosures for HV substations HV substations The solution for > HV/HV and HV/MV substations dp_011_a Strong points 3TT 3TC enclosure These enclosures are designed to regroup the intermediary connections between: • The voltage and current measurement transformers or the tapchanger terminals of the transformer and the LV control cabinet. Advantages Weather conditions The enclosures are MINIPOL boxes (see the SOCOMEC general catalogue), with excellent resistance to weather conditions and UV. 46 Public distribution catalogue Turnkey enclosures The enclosures are delivered assembled and pre-wired. They are ready to be installed on delivery. Flexible configuration With these scalable solutions, SOCOMEC can adapt the solution to best suit your needs. Do not hesitate to contact us for more information. Easy wiring Weather conditions Turnkey enclosure Flexible configuration Compliance with standards > > > > > Function Easy wiring The careful design of these enclosures provides a functional connection of the cables on the different terminals and devices. Connecting the input and output cables at the base of the enclosures is made easier with a removable plate, or, on request, grommet or glands. > > > > S705 HN 46-R-01 IEC 61439 IEC 60269 IEC 60947-3 Collecting units Range of enclosures for HV substations TT collecting units Composition Characteristics coff_402_a TT enclosures, designed to regroup and protect the circuits between the voltage transformers and the LV control cabinet, are equipped with: • IP43 aerator mounted on each side of the enclosure. • A condensate outlet device is mounted on the base section. • Busbar and crossover grounding stud. • Removable closing plate on the base. • Enclosure nameplate on the door. This enclosure is mounted, assembled and pre-wired. Fibreglass-reinforced polyester Colour RAL 7035 Enclosure material IP Enclosure IP55, aerator IP43 1 x 6mm² for voltage terminals; 1 x 25mm² for fuse disconnect switches Connecting cables References Description Internal devices Reference 1TT enclosure 1 fuse disconnect switch 1P+N equipped with 10Agl fuses 8 M6/8 voltage cable terminals 7P70 0001 2TT enclosure 2 fuse disconnect switches 1P+N equipped with 10Agl fuses 10 M6/8 voltage cable terminals 7P70 0002 3TT enclosure 1 fuse disconnect switch 3P+N equipped with 10Agl fuses 8 M6/8 voltage cable terminals 7P70 0003 Dimensions H (mm) W (mm) D (mm) 1TT enclosure Type 400 300 200 2TT enclosure 400 400 200 3TT enclosure 400 400 200 W-70 W+55 W+79 P P-25 minip_005_b_1_gb_cat E H 20 H-30 W D H+54 H+30 H-58 MINIPOL Public distribution catalogue 47 Collecting units Range of enclosures for HV substations 3TC collecting units Composition Characteristics coff_402_a The 3TC enclosure, designed to regroup the connections between the current transformers and the LV control cabinet, is equipped as standard with: • IP43 aerator mounted on each side of the enclosure. • A condensate outlet device is mounted on the base section. • Busbar and crossover grounding stud • Removable closing plate on the base • Enclosure nameplate on the door This enclosure is mounted, assembled and pre-wired. Fibreglass-reinforced polyester Colour RAL 7035 Enclosure material IP Enclosure IP55, aerator IP43 Connecting cables 1 x 10mm² for "current" terminals References Description Internal devices Reference 3TC enclosure 14 current connection terminals with a 10 mm² rod, 16 mm pitch. 7P70 0004 Dimensions Type 3TC enclosure MINIPOL 48 Public distribution catalogue minip_005_b_1_gb_cat W-70 W+55 W+79 P P-25 H-30 20 E H H+54 H+30 H-58 W D H (mm) W (mm) D (mm) 400 300 200 Collecting units Range of enclosures for HV substations 3TC collecting units Composition Characteristics dp_011_a The 3TT-3TC enclosure, designed to regroup and protect the circuits between the voltage and current transformers and the LV control cabinet, is equipped with: • IP43 aerator mounted on each side of the enclosure. • A condensate outlet device is mounted on the base section. • Busbar and crossover grounding stud • Removable closing plate on the base • Enclosure nameplate on the door This enclosure is mounted, assembled and prewired. Fibreglass-reinforced polyester Colour RAL 7035 Enclosure material IP IP55 enclosure, IP43 aerator 1 x 6 mm² for voltage terminals, 1 x 10 mm² for current terminals and 1 x 25 mm² for fuse disconnect switches Connecting cables References Description Internal devices Reference 3TT 3TC enclosure 1 fuse disconnect switch 3P+N equipped with 10Agl fuses 8 M6/8 voltage cable terminals 14 current connection terminals with a 10 mm² rod, pitch of 16 mm. 7P70 0005 Dimensions Type 3TT 3TC enclosure H (mm) W (mm) D (mm) 600 500 230 MINIPOL minip_005_b_1_gb_cat W-70 W+55 W+79 P P-25 H-30 20 E H H+54 H+30 H-58 W D Public distribution catalogue 49 Collecting units Range of enclosures for HV substations Fuse disconnect switches on TT and 3TC enclosures Composition Characteristics rm_070_a rm_075_a The RMSC is a 3-padlock modular fuse disconnect switch equipped with additional security devices: • A safety mechanism prevents any of the grippers from unintentional opening. The user must pass under the cradle to open the disconnector, making this action absolutely voluntary. • A system allows the cradle lock to be padlocked when closed , making it impossible to open the gripper in the event of the cradle coming away by accident. The switch is equipped with an auxiliary contact, which can send a signal (fuse blown, fuse presence) or have an early shut-off function. IEC 60269-1,-2. CE compliance. Electrical features according to IEC 60947-3 Reference standards Thermal current Ith (20 C) 50 Rated insulation voltage Ui (V AC) 690 Prospective short-circuit current (kA eff) 100 Rated impulse withstand voltage Uimp (kV) 8 References Description Internal devices Reference RMSC 1P+N 50A, single-pole + neutral fuse disconnect switches with lock cradle and auxiliary contact, for 14x51 cylindrical fuses 57C2 5032 RMSC 3P+N 50A, 3-pole + neutral fuse disconnect switches with lock cradle and auxiliary contact, for 14x51 cylindrical fuses 57C2 5034 Characteristics Copper wiring recommended (mm2) Fuse rating (A) 16 … 20 Max. torque (Nm) Available current adjustment depending on the temperature 2.5 Temperature (°C) 25 4 20 1 32 6 30 0.95 3 K x In 40 8 40 0.9 50 10 50 0.8 Voltage and current (rated values) 0.1 A to 10 A / 250 VAC Voltage and current (min operating values) 1 mA / 4 VDC Temperature -20 °C to + 125 °C Dimensions 66 50 96 117 Public distribution catalogue 53 118,25 117 106 dp_067_a_1_x_cat 3P+N 96 1P+N Collecting units Range of enclosures for HV substations Collecting units J and H Composition Characteristics coff_402_a J and H enclosures, designed to regroup the intermediate connection between the power transformer (J) or the auto-transformer (H) and the LV control cabinet, are equipped as standard with: • IP43 aerator mounted on each side of the enclosure. • A condensate outlet device is mounted on the base section. • Busbar and crossover grounding stud • Removable closing plate on the base • Enclosure nameplate on the door This enclosure is mounted, assembled and pre-wired. Fibreglass-reinforced polyester Colour RAL 7035 Enclosure material IP IP55 enclosure, IP43 aerator 1 x 6mm² for voltage terminals and 1 x 10mm² for current terminals Connecting cables References Description Internal devices Reference Enclosure J 60 M6/8 voltage cable terminals 6 current connection terminals with a 10 mm² rod, pitch of 16 mm. 7P70 0006 Enclosure H 15 M6/8 voltage cable terminals 11 current connection terminals with a 10 mm² rod, pitch of 16 mm. 7P70 0007 Dimensions H (mm) W (mm) D (mm) Enclosure type J Type 800 600 300 Enclosure type H 400 400 200 MINIPOL minip_005_b_1_gb_cat W-70 W+55 W+79 P P-25 H-30 20 E H H+54 H+30 H-58 W D Public distribution catalogue 51
© Copyright 2026 Paperzz