Product Manual

Product Manual
Model DCT-6 Series
Version 1.2
August 31, 2016
Statement of Use
Each DataCartTM is designed to set a high standard for quality, ease of use, and customer satisfaction. Our goal
is to provide a product that is built to exacting standards and is ready for years of durable service. The DCT-6Li
complies with UL 60601-1 electromagnetic leakage and safety requirements when used in accordance with the
boundaries and suggestions of this manual.
TESTED TO COMPLY WITH:
 UL60601-1: Issued: 2003/04/25 Ed:1 Rev: 2006/04/26 UL Standard for Safety Medical Equipment, Part
1: General Requirements for Safety
RECOMMENDED SHIPPING AND OPERATING CONDITIONS:
 Temperature Range 25°F- 120°F / Humidity Range 10% - 80%
TERMS OF USE: Removing or damaging the serial number will void all cart warranties.
For maximum stability, lower the DataCartTM completely when transporting or rolling over thresholds or other
uneven surfaces.
Warranty Information: http://data-carts.com/downloads/warranty/
Cart Features
Option: Camera & Mount
Option: Large VESA
Display Mount with
Swivel and Tilt Handle
(RUI) Remote User Interface
/ Battery Charge Gauge
Contoured Steering
Handle
Large Medical Grade Laminate
Work Surface with Raised Edge
to Contain Items
Electric Sit/Stand Height
Adjustment
Computer Mouse Holder
Ergonomic Keyboard Tray with
Negative Tilt and Retractable
Left/Right Mouse Tray
Battery
Access Panel
Option: Locking Drawer
Electric Lift
Ergonomically Placed
Foot Rests
Laptop Mounting Solution
5 Lo ki g F o t Caste s
Page | 1
DataCartTM Battery Access
The cart is shipped with the fuses out of the fuse holders.
 Remove lower base access cover by removing (1) Philips head screw.
 Gently lift up and pull back to gain access to Battery and fuse holders.
There will be (2) fuses in a bag taped to the top of the Battery. (10 amps and 40 amps.)
 (2) Spare fuses will be twist tied to the fuse holders coming off the Battery.
 Remove bag and fully insert each rated fuse in the labeled fuse holders.
o The 10-amp fuse protects the lift column
o The 40-amp fuse protects the charging circuit
 You may now reinstall the back access cover.
The battery comes tested from the factory and it is recommended to do a full 12-hour initial charge before
first use.
DataCartTM Laptop / CPU Installation Setup
Unlock and pull work surface towards the rear before attempting to remove then gently lift-up to remove.
Position the Laptop / CPU on the flat surface inside the CPU pan.
 Connect all necessary peripherals at this time.
 (2) 120V AC Receptacles are located in CPU Pan for power.
 USB is located in CPU pan for communication between the power inverter and the CPU.
 Holes in the bottom of the CPU pan are provided to route all cables for all peripherals.
Re-install the work surface by making sure that the work surface rails slide onto the (4) pins on the sides of the
CPU pan and lock the pan.
NOTE: Default Code is 000
DataCartTM VESA Mount Monitor Attachment
Mount monitor with supplied screws that came from monitor manufacturer.
VESA mount is adjustable to view the monitor in the up, down, left and right directions.
 Route all cables through the removable cover in middle section of VESA mount.
 Leave plenty of slack in cables to allow for maximum movement in all directions
Page | 2
DataCartTM Keyboard Tray
The keyboard tray slides in and out, and is adjustable to angle up and down. The keyboard tray adjustment
handle is located on the left side to adjust the tension up and down.
 Pulling straight out on the handle allows the handle to be positioned for easy use.
 Under the keyboard is a slide-out mouse tray.
o The mouse tray will slide out to the left and right of the keyboard tray.
DataCartTM Height Adjustment
The height adjustment switch is located on the right side of the CPU pan enclosure.
 Adjust the height up and down by pressing the triangle buttons.
DataCartTM Locking Wheels
The front wheels have locks to prevent the cart from moving.
 Push each lever down with your foot to engage the locks.
 Push each lever up with your foot to release the locks.
DataCartTM Changing the Lock Combination
The combinatio is fa to set at -0- .
 The Lock must be set on the opening combination prior to resetting.
 On the underside outer edge of the lock there is a hole for the code reset button.
 Rotate the face of the lock until the code reset button comes into view.
o Push this pin in with a paper clip and keep it pushed in.
o Set your personal combination by turning the dials to the desired combination.
o Release the reset button and your combination is set.
*Be sure to save new combination*
Combo Lock
To lo k, otate lo k to lo ked positio . Rotate o e o
dials to your personal combination.
o e dials afte lo k is losed. To open the lock, turn
DataCartTM Battery Charging
The Remote User Interface (RUI) is your on/off button and output power indicator. Pressing the ON/OFF
button for more than 1 second will turn the output on or off. The green Output indicator will be on when
output power is on.
Page | 3
Pressing the Silence button when the MPM is in Battery mode will silence the audible alarm (audible alarm
may be disabled using MP View software)
The fou




atte ha ge gauge lights help ou k o the atte
ha ge le el:
All 4 lights on – battery full
¼ light o G ee – battery ¼ full (75% empty).
¼ light o Yello li ki g – st Lo Batte
a i g i utes e ai i g
¼ light o Red, li ki g – Critical Low Battery warning – se o ds e ai i g .
Recharging Battery: Plug AC cord into 120V AC grounded outlet. Charging will begin automatically.
During recharge each light will blink slowly while that portion of the battery is being recharged.
 For example, 1 light ON, 2nd light blinking means; battery is between 25% and 50% charged, etc.
 Battery is not fully charged until all 4 lights are on without blinking.
Service Required: If eithe Red o Yello
a i g lights a e ON; so e t pe of “e i e is e ui ed.
 Service NOW: RED Alert -- power down your workstation and stop using the cart. Turn the cart power
OFF and disconnect from the wall.
 Service SOON: YELLOW Warning -- power down your workstation as soon as you can. Stop using the
cart. Turn the cart power OFF and disconnect from the wall
For more information regarding the battery and power system, please use the link below to view:

http://data-carts.com/images/uploads/pdfs/POWERVAR_MPM_software_direct_R5.pdf
Technical Specifications
Wo k “u fa e: . 5 W
L
 Height Adjustment: 31.5 Lo x 46 High
Wheelbase: 1 W
L
Weight (Basic Cart Only): 114 lbs.
Battery: Lithium Iron Phosphate
Page | 4
Warnings
Important Warnings
Electrical Shock Warning
The above symbols represent safety warnings that require significant attention when seen on the EMC cart or
in the user manual. Failure to do so could result in minor injury, major injury, or even death.
SERVICE AND REPLACEMENT Do not attempt to service or replace any part of the DataCartTM unless
directed to do so through DataCartTM approved documentation (i.e., this User Manual or other instructions).
Only DataCartTM or a DataCartTM -certified entity may service or replace the cart components. If any
component on the cart is missing or damaged, the cart must not be used. Contact your Reseller or DataCartTM
immediately to request service.
MAINTENANCE
 During preventive maintenance cart should be turned off and unplugged
SAFE WORKING LOADS
 Safe working loads labels must be abided by for all parts
MAXIMUM WEIGHTS:
 Standard Monitor 16 lbs.
 Dual Monitors 8 lbs. on each VESA
 Laptop tray 10 lbs.
 Keyboard tray 5 lbs.
GROUNDING
 Connect the DataCartTM to a e ui ale t e epta le
to ensure ground.
a ked Hospital O l
o
Hospital G ade
DANGEROUS VOLTAGE
 Do not remove battery cover—there may be live parts inside, even when the DataCartTM is
turned off.
DO NOT OPEN THE BATTERY AND POWER SYSTEM COMPARTMENT
 Unauthorized personnel opening the power system compartment may cause injury and/or death.
If the unit is not working properly, please contact Lund Industries, Inc.
DO NOT USE THE UNIT IN OR NEAR WATER OR OTHER LIQUIDS
 If the unit becomes wet, unplug it immediately, wipe away any excess liquid and allow it to dry
before use.
DO NOT TRANSPORT THE CART UP OR DOWN STAIRS
TRANSPORTING
 For maximum stability, lower the DataCartTM completely when rolling over thresholds or other
uneven surfaces.
COIL CORD
 Make sure the coil cord is secure prior to moving the cart
 When disconnecting, pull the plug rather than the cord itself
 Do not use if cord is damaged – contact Lund Industries for a replacement.
Page | 5