CID_ISTHMUS_logic_brochure_(A)

CARBOSTENT
TM
ISTHMUS
Technical data
LOGIC
Stent characteristics
- Stent material: L605 Cobalt Chromium alloy
- Strut surface coating: CarbofilmTM
- 2 radiopaque markers
- Zero stent foreshortening upon expansion
The force of performance
Delivery system
TM
CoCr stent with Carbofilm technology for a bio- nducer surface
UCL
ø 1.71 mm
Device Specifications
Sheath compatibilty: 6F compatible
Guidewire compatibility: .035”
6 fold balloon
Usable Catheter Length (UCL): 75 and 135 cm
Order Information
Length
Size
6.0mm
7.0mm
8.0mm
9.0mm
10.0mm
19mm
29mm
39mm
135
75
135
75
135
ICLC6019L
ICLC7019L
ICLC8019L
ICLC9019L
ICLC10019L
ICLC601S
ICLC7019S
ICLC8019S
ICIL9019S
ICLC10019S
ICLC6029L
ICLC7029L
ICLC8029L
ICLC9029L
ICLC10029L
ICLC6029S
ICLC7029S
ICLC8029S
ICLC9029S
ICLC10029S
ICLC6039L
ICLC70039L
ICLC8039L
ICLC9039L
ICLC10039L
49mm
75
135
ICLC6039S
ICLC6039S ICLC7049L
ICLC8039S ICLC8049L
ICLC9039S ICLC9049L
ICLC10039S
-
59mm
75
135
75
ICLC7049S
ICLC8049S
ICLC9049S
-
ICLC7059L
ICLC8059L
ICLC9059L
-
ICLC7059S
ICLC8059S
ICLC9059S
-
Please contact your local sales representative for product availability
0311 IC0701555610/A
0373
CARBOSTENT
TM
ISTHMUS
LOGIC
Manufactured by: CID S.p.A.
Strada per Crescentino, sn - 13040 Saluggia (VC) Italy
www.cidvascular.com
The images shown within this document are of a purely illustrative nature and are not intended to depict reality.
Bio nducer surface
Radiopaque markers
6F compatible with all sizes
CARBOSTENT
TM
ISTHMUS
LOGIC
Innovative, bio nducer surface
CarbofilmTM, the latest coating from CID, allows a further
Flexible, cell design
Complete stent strut endothelialization
increase in density of pure Carbon while reducing it’s overall
The cellular design guarantees excellent flexibility for optimal conformability to the artery
anatomy, optimal vessel coverage and high, uniform radial force for calcified lesions.
thickness to <0.3μm. This innovative technology brings an
even closer similarity to the diamond structure of pure Carbon
and its exceptional bio/haemo compatibility.
Outstanding radial force
0,8
+ 43%
+ 25%
0,7
0,6
Platinum precision
Radiopaque platinum markers at each end of the stent guarantee pin-point placement.
bar
0,5
and no stent foreshortening
0,4
0,3
0,2
The unique cell architecture, made of cobalt-chromium, with zero foreshortening upon
expansion allows precise positioning.
0,1
0
Competitor B
Stainless Steel
Competitor A
Co-Cr
Isthmus Logic
Co-Cr
CARBOSTENT
TM
ISTHMUS
Technical data
LOGIC
Stent characteristics
- Stent material: L605 Cobalt Chromium alloy
- Strut surface coating: CarbofilmTM
- 2 radiopaque markers
- Zero stent foreshortening upon expansion
Delivery system
UCL
ø 1.71 mm
Device Specifications
Sheath compatibilty: 6F compatible
Guidewire compatibility: .035”
6 fold balloon
Usable Catheter Length (UCL): 75 and 135 cm
Order Information
Length
Size
6.0mm
7.0mm
8.0mm
9.0mm
10.0mm
19mm
29mm
39mm
135
75
135
75
135
ICLC6019L
ICLC7019L
ICLC8019L
ICLC9019L
ICLC10019L
ICLC601S
ICLC7019S
ICLC8019S
ICIL9019S
ICLC10019S
ICLC6029L
ICLC7029L
ICLC8029L
ICLC9029L
ICLC10029L
ICLC6029S
ICLC7029S
ICLC8029S
ICLC9029S
ICLC10029S
ICLC6039L
ICLC7039L
ICLC8039L
ICLC9039L
ICLC10039L
49mm
75
135
ICLC6039S
ICLC7039S ICLC7049L
ICLC8039S ICLC8049L
ICLC9039S ICLC9049L
ICLC10039S
-
59mm
75
135
75
ICLC7049S
ICLC8049S
ICLC9049S
-
ICLC7059L
ICLC8059L
ICLC9059L
-
ICLC7059S
ICLC8059S
ICLC9059S
-
Please contact your local sales representative for product availability
0311 IC0701555610/A
0373
Manufactured by: CID S.p.A.
Strada per Crescentino, sn - 13040 Saluggia (VC) Italy
www.cidvascular.com
The images shown within this document are of a purely illustrative nature and are not intended to depict reality.