CC/QP-231-04/D-0 №2014-S43 Test Report Test Name: Material Outgassing Test Test Material: Fiberglass Insulation Blanket Material Source: Suzhou Long-Range Cryogenic Insulation Material Co., Ltd National Center For Quality Supervision And Inspection of Cryogenic Vessels CC/QP-231-04/D-0 National Center For Quality Supervision And Inspection of Cryogenic Vessels Test Report №2014-S43 Sample Name Page 1, ttl 3 pages Fiberglass Insulation Blanket Type — Trademark LR Samples submitted by Suzhou Long-range Cryogenic Insulation Material Co., Ltd Sample specification Samples produced by Suzhou Long-range Cryogenic Insulation Material Co., Ltd Sample submitted on May, 2014 2014-S43 Sample deliverer Feng Jing Jun National Center For Quality Supervision And Inspection of Cryogenic Vessels Test date May 20th, 2014 -May 27th, 2014 No. of submitted samples Samples tested by Test Sample Sample No. Outgassing rate at normal atmospheric temperature Test result is provided on Page 3 of the Report Test Result (Special seal for inspection report) Issued on: Aug.28th, 2014 Remarks Approved by: Examined by: Prepared by: CC/QP-231-04/D-0 National Center For Quality Supervision And Inspection of Cryogenic Vessels Test Report №2014-S43 Page 2, ttl 3 pages Beginning and ending date May.20th, 2014 - May.27th, 2014 Environmental conditions Ambient temperature 22.9℃~24.6℃ Atmospheric pressure — Relative humidity 28%~29% Main Instruments or devices Seq. Instrument or device name Instrument or Instrument Measurement range Expiry date device model No. or device No. 1 Vacuum gauge DISPLAY ONE (1×105~1×10-5)Pa 230001 20141010 2 Electronic balance XS105DU (0~100)g 112525335 20140822 3 Humiture meter VC230B (-10~50)℃ H48 20150520 Instruments status before test: Instruments status after test: Normal Test sample status before test: Test sample status after test: No damage Remarks: Normal No damage CC/QP-231-04/D-0 National Center For Quality Supervision And Inspection of Cryogenic Vessels Test Report №2014-S43 Page 3, ttl 3 pages Outgassing rate at different pumping time at normal atmospheric temperature is shown in Table I Corresponding outgassing rate change curve is shown in Figure 1. Table 1 Outgassing rate in a static state for 1 hour within 2h, 4h, 6h pumping time at normal atmospheric temperature Outgassing Rate (Pa.m³/s.g) Time (min) pumping time 2h 10 1.27×10 20 7.30×10 30 5.34×10 40 4.48×10 50 3.87×10 60 3.54×10 pumping time 4h pumping time 6h -7 1.18×10 -7 1.18×10 -7 -8 6.60×10 -8 6.36×10 -8 -8 5.19×10 -8 4.56×10 -8 -8 4.13×10 -8 3.54×10 -8 -8 3.39×10 -8 2.92×10 -8 -8 3.06×10 -8 2.59×10 -8 Note: Sample weight M=12.89g Pa•m3/s•g 1.00E-06 ● Pumping 2h ▲ Pumping 4h Pumping 6h 1.00E-07 1.00E-08 0 Table 1 10 20 30 40 50 60 70 min Chang curve of outgassing rate at different time at normal atmospheric temperature
© Copyright 2026 Paperzz