Read an overview of the wear trial and our testing results - Gore-Tex

Field Durability of Barrier and Seam Performance of
GORE® CHEMPAK® Selectively Permeable Fabric in
XRT Suits
© 2009 W. L. Gore & Associates, Inc.
_______________________________________________________________________________
Abstract: Law enforcement professionals are concerned about the durability of current
ChemBio PPE. To evaluate improved functionality and durability of one of the GORE®
CHEMPAK® selectively permeable fabrics, W. L. Gore & Associates undertook an eighthour field trial of the fabric used in Extended Response Team (XRT) suits. Based on
chemical permeation tests, the study indicated that the GORE® CHEMPAK® barrier
used in these suits met representative chemical permeation criteria per NFPA 1994,
Class 3 requirements after eight hours of wear. Additionally, suit inspection and endusers’ feedback indicated the suit was more durable and comfortable than standard
CBRN protective suits.
Objective1
Many first responders point out that ChemBio personal protective equipment
(PPE) tends to lose protective capabilities after extended use. This is extremely
detrimental, as any loss of protection increases risk of harm to the first responder.
Additionally, the suits tend to be extremely hot and cause first responders to be
delayed due to lengthy donning time. Gore undertook an eight-hour field trial to
evaluate and quantify the chemical permeation performance of GORE®
CHEMPAK® selectively permeable fabric, as used in the Extended Response
Warning: The data in this paper is derived from specific reported and evaluated field data. This
paper does not represent data or performance that will necessarily result from other field tests or
in use. No products, including garments, footwear, or gloves can provide absolute protection,
even when new. Additionally, product performance will decline with wear, tear, abrasion, and
other damage associated with use.
1
Field Durability of GORE® CHEMPAK®
Selectively Permeable Fabric in XRT Suit
Team (XRT) suit, after a long period of use. Furthermore, this study was used to
elicit feedback from end-users on the reliability and breathability of the light
weight XRT suit.
Background
W. L. Gore & Associates developed a ChemBio protective fabric to be used in
the XRT suit, a single-use, breathable suit designed for quick donning without
requiring any additional chemical taping. The fabric used in the suit is tailored to
meet the demands of ChemBio protection, durability, and comfort from the first
responder community. Since ChemBio protective materials can be tested in a
variety of ways, which can often lead to confusion about the level of protection
actually offered by a material, Gore certifies its ChemBio products to relevant
third-party standards. Although several standards are in development, NFPA
1994 Standard on Protective Ensembles for First Responders for CBRN Terrorism
Incidents, 2007 edition is the only one recognized by the Department of
Homeland Security as of January 2009.
This standard offers an excellent basis for characterizing a barrier material’s
permeation resistance against chemical warfare agents and toxic industrial
chemicals. However, since NFPA 1994 does not specify minimum standards for
permeation performance after wear, Gore undertook this field trial to provide
additional information for first responders regarding material and seam durability
after realistic usage.
Trial Details
The XRT ensemble used in the trial was a single-piece coverall with an attached
hood and fully integrated gloves and booties. It was created to Gore’s
specifications using a GORE® CHEMPAK® selectively permeable fabric, and this
ensemble was given to members of a participating law enforcement team. All
Page 2
Field Durability of GORE® CHEMPAK®
Selectively Permeable Fabric in XRT Suit
members were required to wear a full-face air purifying respirator, and some
members chose to wear additional equipment such as gun belts, load-bearing
vests, etc.
The trial was a single extended evaluation of the suit during simulated warm
zone operations in response to a CBRN terrorism incident. During the eight-hour
period, the suits underwent two full don-and-doff cycles and three partial donand-doff cycles.
Temperatures during the day ranged from 58°F to 83°F, and it was bright and
sunny while the participants underwent various selected activities: a two-mile
brisk hike, range shooting with hand guns and shotguns, navigation through an
obstacle course, and on-scene intelligence gathering. In addition, the entire
group was asked to respond to fourteen questions about the performance of
the garment and provide feedback using a ranking system.
Testing and Analysis
All participants successfully completed the eight-hour field trial without
experiencing discomfort due to heat stress, thermal burden, or sweat buildup.
After the field trial was completed, Gore performed chemical permeation tests
on material and seams according to methodology specified in NFPA 1994 [2007
edition] for Class 3 garments. Thirty representative samples were selected from
the garments, and ten samples each were used for three chemicals from the
standard: a blister agent, a nerve agent, and a toxic industrial chemical. The
results for each chemical permeation test were then tabulated and compared
to the Class 3 performance requirements as stated in NFPA 1994 [2007 edition].
Results and Conclusions
Inspection of the suits after the wear trial revealed no seam failures, rips, or
Page 3
Field Durability of GORE® CHEMPAK®
Selectively Permeable Fabric in XRT Suit
punctures through the protective barrier. The permeation test results indicated
that the GORE® CHEMPAK® selectively permeable fabric used in the XRT suit
exceeded the NFPA 1994, class 3 requirements — even after eight hours of wear
— for permeation of the selected chemicals. These results should give the user a
great deal of confidence in the barrier’s protective properties in similar
situations. Furthermore, the end-user feedback solicited from this test showed
that the XRT suit was more comfortable, allowed longer engagement, and was
easier to doff and don than traditional CBRN ensembles.
Selection of ChemBio PPE is a critical and multifaceted decision that must take
into account both “out-of-bag” and “after-wear” protective performance.
While there are many lab tests that can be useful in determining these factors,
the only true test is actual field usage. As always, common sense, regular
inspection, good judgment, and compliance with manufacturer’s care
instructions should be used to maximize the protective capability and life of PPE.
For further details regarding this field trial, please contact Gore at 800.431.GORE
(800.431.4673) or at [email protected].
Page 4