Staff report DATE: January 13, 2009 TO: Chair and Directors Electoral Areas Services Committee FROM: Debra Oakman, CMA Chief Administrative Officer RE: DEVELOPMENT VARIANCE PERMIT AND FLOODPLAIN RELIEF APPLICATIONS FILES: 3090-20 / DV 10B 08 3160-20 / FR 1B 08 FOLIO NO.: 771 03535.000 PID NO.: 003-867-951 APPLICANT: David Robinson (0775700 BC LTD.) AGENT: Graham Elvidge, Allan Diamond Architect LEGAL DESCRIPTION: Lot 7, District Lot 224, Comox District, Plan 18066 CIVIC ADDRESS: 1209 Mayfair Road OCP BYLAW: Bylaw No. 2042, Rural Comox Valley OCP Bylaw, 1998 OCP DESIGNATION: Residential ZONING BYLAW: Bylaw No. 2781, Comox Valley Zoning Bylaw, 2005 ZONE: Residential One (R-1) PURPOSE The applicant wishes to construct a new single family dwelling and detached garage on the subject property. The proposed siting of the dwelling requires the approval of a front and rear yard setback variance. In addition, the proposed siting of the detached garage requires the approval of a front and right side yard setback variance. Lastly, the proposed siting of the single family dwelling also requires floodplain relaxation from the Strait of Georgia. POLICY ANALYSIS The Local Government Act (LGA) grants authority to local governments under Section 922 of Part 26 “Planning and Land Use Management” to vary provisions of a bylaw, on applications by a landowner, through the issuance of a development variance permit. EXECUTIVE SUMMARY The applicant wishes to have the setbacks of the single family dwelling and detached garage varied, as well as, the floodplain setback for the dwelling relaxed to permit the siting of the proposed structures. Planning staff supports these variances due to the configuration of the property, the loss of approximately 8.0 metres (26.2 feet) of land due to wave action and the area required for the septic field, the building envelope for the property is significantly reduced. In addition, the Ministry of Transportation and Infrastructure (TRAN) has granted a permit for the road setback variances. Lastly, Levelton Engineering’s geotechnical engineer supports the reduction of the floodplain setback. Based on the above, planning staff recommends the issuance of the development variance permit (DVP) and floodplain relief. Staff Report – DV 10B 08 – FR 1B 08 (Robinson-Allan Diamond Architects Page 2 RECOMMENDATIONS THAT the board approve development variance permit DV 10B 08 (Robinson-Allan Diamond Architect) for the construction of a new single family dwelling with a front yard setback reduction from the required 4.5 metres (14.8 feet) to 3.3 metres (10.8 feet) and a rear yard setback reduction from the required 4.5 metres to 1.75 metres (5.7 feet); and the construction of a detached garage with a front yard setback reduction from the required 4.5 metres (14.8 feet) to 1.0 metre (3.3 feet) and a right side yard setback variance from the required 1.75 metres (5.7 feet) to 1.0 metre (3.3 feet); AND FURTHER THAT the floodplain management provisions as contained in Bylaw No. 2782, being the “Floodplain Management Bylaw, 2005”, be varied for the proposed single family dwelling for the purposes of relaxing the required floodplain setback from 15.0 metres (49.2 feet) to 11.5 metres (37.7 feet) from the natural boundary of the sea for the property described as Lot 7, District Lot 224, Comox District, Plan 18066 (1209 Mayfair Road) in accordance with the geotechnical reports dated September 11, 2008 and November 28, 2008, by Levelton Engineering Solutions; AND FURTHER THAT the geotechnical reports by Levelton Engineering Solutions dated September 11, 2008 and November 28, 208 be registered on title by covenant; AND FINALLY THAT the manager of legislative services be authorized to execute the permit. Respectfully: D. Oakman Debra Oakman, CMA Chief Administrative Officer BACKGROUND The subject property is located in a residential area of Lazo North (Electoral Area ‘B’) and is zoned Residential One (R-1). The parcel is 0.15 hectares (0.37 acres) in area and is bounded by the Mayfair Road beach access to the northwest and the Strait of Georgia to the northeast (subject property map attached). The former mobile home has been removed from the parcel and the applicant wishes to develop the property by constructing a new single family dwelling and detached garage. The applicant has also recently received regional district approval for the construction of a new engineered cement shoreline protection device within 1.0 metre (3.3 feet) of the natural boundary of the sea in order to safeguard the property from further storm action. The initial plans for the development met the required floodplain setback as the applicant originally applied for the installation of the new foreshore protection wall approximately 4.0 metres (13.1 feet) from the existing natural boundary to gain back a portion of the 8.0 metres (26.2 feet) of land that had been lost due to erosion. Following discussions with the Integrated Land Management Bureau (ILMB), which is the authority responsible for crown land, staff confirmed that any land below a newly established natural boundary is under the jurisdiction of the crown. As such, this proposal would not be permitted unless an application for a license of occupation was submitted and approved by ILMB. As a result, the applicant chose to revise the plans and apply to place the new wall within 1.0 metre (3.3 feet) of the existing natural boundary, as permitted by ILMB. The outcome of this amendment, however, resulted in an overall reduction to the area between the proposed dwelling and the natural boundary and ultimately the requirement for a floodplain relaxation. In order to permit the proposed siting of the dwelling and detached garage, a DVP and floodplain relief are required. Staff Report – DV 10B 08 – FR 1B 08 (Robinson-Allan Diamond Architects Page 3 PLANNING ANALYSIS Allan Diamond Architects have provided a site plan which identifies the siting of both the single family dwelling and detached garage (site survey attached as Schedule ‘A’). As part of the review process, the site plan revealed that two variance requests are associated with each of the proposed structures, the single family dwelling and detached garage accessory building, as well as, floodplain relaxation for the dwelling. Specifically, planning staff confirmed that the dwelling requires both a front and rear yard variance, as well as, floodplain relief and the detached garage requires both a front and right side yard setback variance. Variance Requests Firstly, the single family dwelling requires both a front and rear yard setback variance. Secondly, the detached garage requires a front and right side yard setback. The applicant is seeking approval of the variances in order to permit the siting of these structures as initially proposed. The site plan confirms that the single family dwelling, is proposed within 3.3 metres (10.8 feet) of the front yard lot line and 1.75 metres (5.7 feet) of the rear yard lot line. It also confirms that the detached garage is proposed within 1.0 metre (3.3 feet) of the front lot yard lot line and 1.0 metre (3.3 feet) of the rear yard lot line. During the review of the application, staff has found cause for support of the variance requests. Firstly, the configuration of the property, specifically the designation of the front and rear yards, results in the largest setback requirements at both ends of the narrowest portion of the lot (see Schedule ‘A’). Typically, the front and rear sides of the property are situated at opposite ends of the longest section of the parcel. However, in this case a total of 9.0 metres (29.6 feet) of setback is required along a portion of the parcel that is approximately 19.0 metres (62.0 feet) in length. Secondly, the loss of approximately 8.0 metres (26.2 feet) of land adjacent to the foreshore and the required setback from the natural boundary significantly reduces the land available at the east side of the property. Lastly, due to environmental protection of the foreshore and marine environment, the septic system is located at the far west corner of the property, farthest away from the foreshore. As such, the area required for the septic system further reduces the building envelope for the development. Floodplain Relaxation With respect to the floodplain relief portion of this application, the design of the single family dwelling adheres to the 1.5 metre (3.3 foot) flood construction level required by Bylaw No. 2782, however, the proposal does not meet the required 15.0 metre (49.2 foot) setback requirement from natural boundary. As the applicant would like to maintain the original design, they are requesting relief of the required 15.0 metre (49.2 foot) floodplain setback to permit the proposed siting of the single family dwelling. Although the outermost foundation wall of the dwelling is proposed at 13.2 metres (43.3 feet) from the natural boundary, there is a patio roof post proposed at 11.5 metres (37.7 feet) from the natural boundary. To account for the siting of the post, the floodplain relaxation is requested for 11.5 metres (37.7 feet) from the natural boundary of the sea. To address any potential issues arising from the floodplain relaxation and to provide geotechnical requirements associated with the development, the applicant retained Levelton Engineering to complete a geotechnical assessment. Tom Oxland, P.Eng. of Levelton Engineering, prepared two reports, dated September 11th and November 28th, 2008. The reports state that the dwelling would be safe under the proposed conditions, specifically the construction of a higher seawall and an increase in the general site/yard elevation, and the property would be safe from a geotechnical perspective for the single family residence use intended (report attached as Schedule ‘B’). As part of the approval process and to release the regional district from any liability, the planning department requires that these reports form a schedule to the development permit and be registered on title. Given that this geotechnical report will be registered on title, planning staff supports floodplain relief for the single family dwelling, at 11.5 metres (37.7 feet) from the natural boundary of the sea. Staff Report – DV 10B 08 – FR 1B 08 (Robinson-Allan Diamond Architects Page 4 In summary, as cause for the variances are present and as planning staff does not foresee the relaxations as having an adverse effect on adjacent property owners, staff supports the approval of the aforementioned variances and floodplain relief to permit the siting of the proposed single family dwelling and detached garage. CITIZEN/PUBLIC RELATIONS IMPLICATIONS Adjacent property owners will be notified a minimum of ten days prior to the electoral areas services committee (EASC) meeting regarding the variance. Any additional resident correspondence or comments received by planning staff will be provided to the committee at the February 16, 2009 EASC meeting. INTERDEPARTMENTAL INVOLVEMENT/IMPLICATIONS This application was forwarded to the operational services department on January 15, 2009 for review and comment. These comments were received on January 21, 2009 and state that the subject property, at 1209 Mayfair Road, is serviced by CVRD water however no negative impacts are anticipated from the proposed variances or floodplain releif. In addition, there is no sewer service to this property and thus no objections in that regard. Respectfully submitted: T. Knight Thomas Knight Manager of Planning Services Property Services Branch Prepared by: A. Nelson, Planning Technician II Staff Report – DV 10B 08 – FR 1B 08 (Robinson-Allan Diamond Architects Page 5 DV 10B 08 – FR 1B 08 – DP 18B Subject Property Map Staff Report – DV 10B 08 – FR 1B 08 (Robinson-Allan Diamond Architects Page 6 Front Left Side Figure 1: View of Property from Foreshore Rear Front Figure 2: View of Property from Mayfair Road Left Side Front Rear Right Side Figure 3: View from Right Side of Property to Foreshore Figures 1-3 Staff Report – DV 10B 08 – FR 1B 08 (Robinson-Allan Diamond Architects Page 7 LEFT Schedule ‘A’ Mayfair Road Dwelling Rear Yard Variance to 1.75m RIGHT FRONT Dwelling Front Yard Variance to 3.3m REAR Proposed location of Shoreline Protection Wall. Wall is permitted to extend a Dwelling Floodplain maximum of 1.0 metresRelaxation to 11.5m beyond the present natural boundary. Garage Front Yard Variance to 1.0m Garage Right Side Yard Variance to 1.0m Site Plan Staff Report – DV 10B 08 – FR 1B 08 (Robinson-Allan Diamond Architects Page 8 Staff Report – DV 10B 08 – FR 1B 08 (Robinson-Allan Diamond Architects Schedule ‘B’ Page 9
© Copyright 2026 Paperzz