STRAIGHT PIPES SERIES 1
Lenght L = 12 m
PRODUCER
INSTALL ENGINEERING SV LTD
DIAMETER
NOMINAL DIAMETER
DN
mm
20
25
32
40
50
65
80
100
125
150
200
250
300
350
400
450
500
600
700
800
JACKET PIPE DP
mm
90
90
110
110
125
140
160
200
225
250
315
400
450
500
560
560
630
710
800
900
SERVICE PIPE DM
mm
ф26.9x2.0
ф33.7x2.3
ф42.4x2.6
ф48.3x2.6
ф60.3x2.9
ф76.1x2.9
ф88.9x3.2
ф114.3x3.6
ф139.7x3.6
ф168.3x4.0
ф219.1x4.5
ф273.0x5.0
ф323.9x5.6
ф355.6x5.6
ф406.4x6.3
ф457.0x6.3
ф508.0x6.3
ф610.0x7.1
ф711.0x8.8
ф813.0x8.8
WEIGHT
WATER
CONTENT
kg/m
2.5
3.1
4.3
4.6
6.1
7.4
9.4
13.6
16.6
21.5
31.9
46.3
60.0
68.3
86.9
91.6
105,4
138.0
190,2
222.0
l/m
0.4
0.6
1.1
1.5
2.3
3.9
5.3
9.0
13.8
20.2
34.7
54.3
76.8
93.1
122.0
155.0
193.0
277.0
378.0
497.0
HOW TO ORDER:
АААA-DМ
DМ - Outer service pipe diameter in mm
ААAА - Item
0011 - For HDPE jacket pipe
0021 - For spiral folded jacket pipe
0031 - For steam service pipe with HDPE jacket pipe
0041 - For steam service pipe with spiral folded jacket pipe
Remarks:
- The service pipe can be produced from carbonic or
stainless steel, copper, polyethylene or another material,
according to client's order.
- The cover pipe can be produced from polyethylene or
galvanized sheet iron respectively for underground and
above-ground installation.
- When the working fluid is steam, the heat insulation is
increased with an additional heat-resistant layer,
determined according to steam temperature.
- Dimensions may vary according to client's request.
12 m
Dp
DM
4000 Plovdiv, 5 Dyakon Ilarion str
tel: (032) 635 542, fax: (032) 268 547
e-mail: [email protected]; www.installpipe.com
1
STRAIGHT PIPES SERIES 2
Lenght L = 12 m
PRODUCER
NOMINAL
DIAMETER
DN
mm
20
25
32
40
50
65
80
100
125
150
200
250
300
350
400
450
500
600
700
800
INSTALL ENGINEERING SV LTD
DIAMETER
JACKET PIPE DP
mm
110
110
125
125
140
160
180
225
250
280
355
450
500
560
630
630
710
800
900
1000
SERVICE PIPE DM
mm
ф26.9x2.0
ф33.7x2.3
ф42.4x2.6
ф48.3x2.6
ф60.3x2.9
ф76.1x2.9
ф88.9x3.2
ф114.3x3.6
ф139.7x3.6
ф168.3x4.0
ф219.1x4.5
ф273.0x5.0
ф323.9x5.6
ф355.6x5.6
ф406.4x6.3
ф457.0x6.3
ф508.0x6.3
ф610.0x7.1
ф711.0x8.8
ф813.0x8.8
WEIGHT
WATER
CONTENT
kg/m
3.0
3.5
4.6
5.0
6.5
8.0
10.1
14.8
17.7
21.5
35.1
51.1
65.5
75.7
96.3
101.0
118.0
153.6
210.0
246.0
l/m
0.4
0.6
1.1
1.5
2.3
3.9
5.3
9.0
13.8
20.2
34.7
54.3
76.8
93.1
122.0
155.0
193.0
277.0
378.0
497.0
HOW TO ORDER:
АААA-DМ
DМ - Outer service pipe diameter in mm
АААA - Item
0012 - For HDPE jacket pipe
0022 - For spiral folded jacket pipe
0032 - For steam service pipe with HDPE jacket pipe
0042 - For steam service pipe with spiral folded jacket pipe
Remarks:
- The service pipe can be produced from carbonic or
stainless steel, copper, polyethylene or another
material, according to client's order.
- The cover pipe can be produced from polyethylene
or galvanized sheet iron respectively for underground
and above-ground installation.
- When the working fluid is steam, the heat insulation
is increased with an additional heat-resistant layer,
determined according to steam temperature.
- Dimensions may vary according to client's request.
12 m
Dp
DM
4000 Plovdiv, 5 Dyakon Ilarion str
tel: (032) 635 542, fax: (032) 268 547
e-mail: [email protected]; www.installpipe.com
2
STRAIGHT PIPES SERIES 3
Lenght L = 12 m
PRODUCER
INSTALL ENGINEERING SV LTD
DIAMETER
NOMINAL DIAMETER
DN
mm
20
25
32
40
50
65
80
100
125
150
200
250
300
350
400
450
500
600
700
JACKET PIPE DP
mm
125
125
140
140
160
180
200
250
280
315
400
500
560
630
710
710
800
900
1000
SERVICE PIPE DM
mm
ф26.9x2.0
ф33.7x2.3
ф42.4x2.6
ф48.3x2.6
ф60.3x2.9
ф76.1x2.9
ф88.9x3.2
ф114.3x3.6
ф139.7x3.6
ф168.3x4.0
ф219.1x4.5
ф273.0x5.0
ф323.9x5.6
ф355.6x5.6
ф406.4x6.3
ф457.0x6.3
ф508.0x6.3
ф610.0x7.1
ф711.0x8.8
WEIGHT
WATER
CONTENT
kg/m
3.3
3.9
5.0
5.4
7.1
8.7
10.9
16.2
19.9
25.7
39.0
46.3
76.9
85.1
108.8
113.5
133.6
173.0
231.8
l/m
0.4
0.6
1.1
1.5
2.3
3.9
5.3
9.0
13.8
20.2
34.7
54.3
76.8
93.1
122.0
155.0
193.0
277.0
378.0
HOW TO ORDER:
ААAА-DМ
DМ - Outer service pipe diameter in mm
АААA - Item
0013 - For HDPE jacket pipe
0023 - For spiral folded jacket pipe
0033 - For steam service pipe with HDPE jacket pipe
0043 - For steam service pipe with spiral folded jacket pipe
Remarks:
- The service pipe can be produced from carbonic or
stainless steel, copper, polyethylene or another material,
according to client's order.
- The cover pipe can be produced from polyethylene or
galvanized sheet iron respectively for underground and
above-ground installation.
- When the working fluid is steam, the heat insulation is
increased with an additional heat-resistant layer,
determined according to steam temperature.
- Dimensions may vary according to client's request.
12 m
Dp
DM
4000 Plovdiv, 5 Dyakon Ilarion str
tel: (032) 635 542, fax: (032) 268 547
e-mail: [email protected]; www.installpipe.com
3
PRE-INSULATED CURVED PIPES SERIES 1, 2 AND 3
Lenght L = 12 m
PRODUCER
DN
INSTALL ENGINEERING SV LTD
DIAMETER
mm
SERVICE
PIPE
mm
20
25
32
40
50
65
80
100
125
150
200
250
300
350
400
ф26.9x2.0
ф33.7x2.3
ф42.4x2.6
ф48.3x2.6
ф60.3x2.9
ф76.1x2.9
ф88.9x3.2
ф114.3x3.6
ф139.7x3.6
ф168.3x4.0
ф219.1x4.5
ф273.0x5.0
ф323.9x5.6
ф355.6x5.6
ф406.4x6.3
MAXIMUM BENDING
ANGLE Y
WEIGHT
JACKET PIPE
mm
Series 1 Series 2 Series 3 Series 1
90
110
125
2.5
90
110
125
3.1
110
125
140
4.3
110
125
140
4.6
125
140
160
6.1
140
160
180
7.4
160
180
200
9.4
200
225
250
13.6
225
250
280
16.6
250
280
315
21.5
315
355
400
31.9
400
450
500
46.3
450
500
560
60.0
500
560
630
68.3
560
630
710
86.9
kg/m
Series 2
3.0
3.5
4.6
5.0
6.5
8.0
10.1
14.8
17.7
21.5
35.1
51.1
65.5
75.7
96.3
Series 3 Series 1 Series 2 Series 3
35 O
35 O
35 O
3.3
O
O
35
35
35 O
3.9
O
O
35
35
35 O
5.0
O
O
35
35
35 O
5.4
O
O
35
35
35 O
7.1
O
O
35
35
35 O
8.7
O
O
35
35
35 O
10.9
O
O
35
35
35 O
16.2
O
O
35
35
35 O
19.9
O
O
35
35
35 O
25.7
O
O
25
25
25 O
39.0
O
O
20
20
20 O
46.3
O
O
15
15
15 O
76.9
O
O
15
15
15 O
85.1
O
O
15
15
15 O
108.8
HOW TO ORDER:
АААA-DМ/Y
Y - Bending angle in degrees
DМ - Outer service pipe diameter in mm
ААAА - Item
0051 - For Series 1
0052 - For Series 2
0053 - For Series 3
Remarks:
- The service pipe can be produced from carbonic or
stainless steel, copper, polyethylene or another material,
according to client's order.
- The cover pipe can be produced from polyethylene or
galvanized sheet iron respectively for underground and
above-ground installation.
- When the working fluid is steam, the heat insulation is
increased with an additional heat-resistant layer, determined
according to steam temperature.
- Dimensions may vary according to client's request.
Y
4000 Plovdiv, 5 Dyakon Ilarion str
tel: (032) 635 542, fax: (032) 268 547
e-mail: [email protected]; www.installpipe.com
4
PRE-INSULATED BENDS SERIES 1, 2 AND 3
Bending angle Y=90, 105, 120, 135, 150 and 165 degrees and upon request
PRODUCER
INSTALL ENGINEERING SV LTD
NOMINAL
DIAMETER
DN
mm
20
25
32
40
50
65
80
100
125
150
200
250
300
350
400
450
500
600
700
800
DIAMETER
JACKET PIPE
SERVICE
PIPE
mm
ф26.9x2.0
ф33.7x2.6
ф42.4x2.6
ф48.3x2.6
ф60.3x2.9
ф76.1x2.9
ф88.9x3.2
ф114.3x3.6
ф139.7x3.6
ф168.3x4.0
ф219.1x4.5
ф273.0x5.0
ф323.9x5.6
ф355.6x5.6
ф406.4x6.3
ф457.0x6.3
ф508.0x6.3
ф610.0x7.1
ф711.0x8.8
ф813.0x8.8
LENGTH
mm
Series 2
110
110
125
125
140
160
180
225
250
280
355
450
500
560
630
630
710
800
900
1000
Series 1
90
90
110
110
125
140
160
200
225
250
315
400
450
500
560
560
630
710
800
900
HOW TO ORDER:
ААAА-DМ/Y
Y - Bending angle in degrees
DМ - Outer service pipe diameter in mm
АААA - Item
0111 - For Series 1 with HDPE jacket pipe
0112 - For Series 2 with HDPE jacket pipe
0113 - For Series 3 with HDPE jacket pipe
0121 - For Series 1 with spiral folded jacket pipe
0122 - For Series 2 with spiral folded jacket pipe
0123 - For Series 3 with spiral folded jacket pipe
L
mm
Series 3
125
125
140
140
160
180
200
250
280
315
400
500
560
630
710
710
800
900
1000
1000
1000
1000
1000
1000
1000
1000
1000
1000
1000
1200
1200
1200
1200
1200
1600
1600
1600
1700
1850
0131 - For steam Series 1 with HDPE jacket pipe
0132 - For steam Series 2 with HDPE jacket pipe
0133 - For steam Series 3 with HDPE jacket pipe
0141 - For steam Series 1 with spiral folded jacket pipe
0142 - For steam Series 2 with spiral folded jacket pipe
0143 - For steam Series 2 with spiral folded jacket pipe
Remarks:
- The service pipe can be produced from carbonic or
stainless steel, copper, polyethylene or another
material, according to client's order.
- The cover pipe can be produced from polyethylene
or galvanized sheet iron respectively for underground
and above-ground installation.
- When the working fluid is steam, the heat insulation
is increased with an additional heat-resistant layer,
determined according to steam temperature.
- Dimensions may vary according to client's request.
L
Y
L
4000 Plovdiv, 5 Dyakon Ilarion str
tel: (032) 635 542, fax: (032) 268 547
e-mail: [email protected]; www.installpipe.com
5
BEND SHELLS
Bending angle Y = 90, 120, 135 and 150 degrees and upon request
PRODUCER
INSTALL ENGINEERING SV LTD
POLYETHYLENE PIPE DIAMETER D
LENGTH L
90
110
125
140
160
180
200
250
mm
360
370
380
420
440
470
540
700
HOW TO ORDER
0150-D/Y
Y - Bending angle in degrees
D - Outer diameter of polyethylene pipe in mm
Remarks:
- The shell, which is produced from
polyethylene, is consisted of two parts,
joined by bolts.
- After installation, the space between
the shell and the service pipe is filled
with polyurethane foam.
L
Y
L
D
4000 Plovdiv, 5 Dyakon Ilarion str
tel: (032) 635 542, fax: (032) 268 547
e-mail: [email protected]; www.installpipe.com
6
PRE-INSULATED T-PIECES SERIES 1, 2 AND 3
Deviation angle: 90 degrees
PRODUCER
INSTALL ENGINEERING SV LTD
NOMINAL DIAMETER
MAIN PIPE DNM
BRANCH PIPE DNO
mm
mm
25-200
25-80
100-200
100-200
250-800
25-80
250-800
100-200
250-800
250-600
LENGTH
L1
mm
1200
1500
1200
1500
1800
L2
mm
1000
1000
1200
1200
1500
HOW TO ORDER
АААA-DNM/DNO
DNО - Branch service pipe nominal diameter in mm
DNM - Main service pipe nominal diameter in mm
АААA - Item
0211 - For Series 1 with HDPE jacket pipe
0231 - For steam Series 1 with HDPE jacket pipe
0212 - For Series 2 with HDPE jacket pipe
0232 - For steam Series 2 with HDPE jacket pipe
0213 - For Series 3 with HDPE jacket pipe
0233 - For steam Series 3 with HDPE jacket pipe
0221 - For Series 1 with spiral folded jacket pipe 0241 - For steam Series 1 with spiral folded jacket pipe
0222 - For Series 2 with spiral folded jacket pipe 0242 - For steam Series 2 with spiral folded jacket pipe
0223 - For Series 3 with spiral folded jacket pipe 0243 - For steam Series 2 with spiral folded jacket pipe
Remarks:
L2
-The service pipe can be produced from carbonic or stainless steel, copper,
polyethylene or another material, according to client's order.
- The cover pipe can be produced from polyethylene or galvanized sheet iron
respectively for underground and above-ground installation.
- When the working fluid is steam, the heat insulation is increased with an additional
heat-resistant layer, determined according to steam temperature.
- Dimensions may vary according to client's request.
- The branch pipe diameter cannot exceed the diameter of the service pipe.
L1
4000 Plovdiv, 5 Dyakon Ilarion str
tel: (032) 635 542, fax: (032) 268 547
e-mail: [email protected]; www.installpipe.com
7
PERPENDICULAR T-PIECES SERIES 1, 2 AND 3
Deviation angle 90 degrees
Length - Main pipe 1.2 m, branch pipe 0.7 m
PRODUCER
INSTALL ENGINEERING SV LTD
NOMINAL DIAMETER
MAIN PIPE DNM
mm
25-200
BRANCH PIPE DNO
mm
25-200
HOW TO ORDER
АААA-DNM/DNO
DNО - Branch service pipe nominal diameter in mm
DNM - Main service pipe nominal diameter in mm
АААA - Item
0311 - For Series 1 with HDPE jacket pipe
0312 - For Series 2 with HDPE jacket pipe
0313 - For Series 3 with HDPE jacket pipe
0321 - For Series 1 with spiral folded jacket pipe
0322 - For Series 2 with spiral folded jacket pipe
0323 - For Series 3 with spiral folded jacket pipe
0331 - For steam Series 1 with HDPE jacket pipe
0332 - For steam Series 2 with HDPE jacket pipe
0333 - For steam Series 3 with HDPE jacket pipe
0341 - For steam Series 1 with spiral folded jacket pipe
0342 - For steam Series 2 with spiral folded jacket pipe
0343 - For steam Series 2 with spiral folded jacket pipe
Remarks:
700
1200
-The service pipe can be produced from carbonic or
stainless steel, copper, polyethylene or another material,
according to client's order.
- The cover pipe can be produced from polyethylene or
galvanized sheet iron respectively for underground and
above-ground installation.
- When the working fluid is steam, the heat insulation is
increased with an additional heat-resistant layer,
determined according to steam temperature.
- Dimensions may vary according to client's request.
- The branch pipe diameter cannot exceed the diameter
of the service pipe.
4000 Plovdiv, 5 Dyakon Ilarion str
tel: (032) 635 542, fax: (032) 268 547
e-mail: [email protected]; www.installpipe.com
8
PARALLEL T-PIECES SERIES 1, 2 AND 3
PRODUCER
MAIN PIPE DNM
mm
25-400
125-500
INSTALL ENGINEERING SV LTD
NOMINAL DIAMETER
BRANCH PIPE DNO
mm
25-100
125-300
LENGTH L
mm
1200
1500
HOW TO ORDER
АAАА-DNM/DNO
DNО - Branch service pipe nominal diameter in mm
DNM - Main service pipe nominal diameter in mm
АAАА - Item
0411 - For Series 1 with HDPE jacket pipe
0412 - For Series 2 with HDPE jacket pipe
0413 - For Series 3 with HDPE jacket pipe
0421 - For Series 1 with spiral folded jacket pipe
0422 - For Series 2 with spiral folded jacket pipe
0423 - For Series 3 with spiral folded jacket pipe
0431 - For steam Series 1 with HDPE jacket pipe
0432 - For steam Series 2 with HDPE jacket pipe
0433 - For steam Series 3 with HDPE jacket pipe
0441 - For steam Series 1 with spiral folded jacket pipe
0442 - For steam Series 2 with spiral folded jacket pipe
0443 - For steam Series 2 with spiral folded jacket pipe
Remarks:
- The service pipe can be produced from carbonic or
stainless steel, copper, polyethylene or another material,
according to client's order.
- The cover pipe can be produced from polyethylene or
galvanized sheet iron respectively for underground and
above-ground installation.
- When the working fluid is steam, the heat insulation is
increased with an additional heat-resistant layer,
determined according to steam temperature.
- Dimensions may vary according to client's request.
- The branch pipe diameter cannot exceed the diameter
of the service pipe.
150
L
4000 Plovdiv, 5 Dyakon Ilarion str
tel: (032) 635 542, fax: (032) 268 547
e-mail: [email protected]; www.installpipe.com
9
T-PIECES SHELLS
Deviation angle 90 degrees
Main pipe length = 450 mm
PRODUCER
INSTALL ENGINEERING SV LTD
NOMINAL DIAMETER
MAIN PIPE DNM
BRANCH PIPE DNO
mm
mm
125
110
140
125
160
125
140
180
125
140
160
200
160
180
LENGTH L2
mm
190
200
220
210
300
215
220
230
240
HOW TO ORDER
0450-DNM/DNO
DNО - Branch service pipe nominal diameter in mm
DNM - Main service pipe nominal diameter in mm
L2
450
Remarks:
- The shell, which is produced
from polyethylene, is consisted
of two parts, joined by bolts.
- After installation, the space
between the shell and the
service pipe is filled with
polyurethane foam.
DNM
4000 Plovdiv, 5 Dyakon Ilarion str
tel: (032) 635 542, fax: (032) 268 547
e-mail: [email protected]; www.installpipe.com
10
PRE-INSULATED AIR RELEASE/DRAINAGE UNITS SERIES 1, 2 AND 3
Length L = 1.2 m
PRODUCER
INSTALL ENGINEERING SV LTD
NOMINAL DIAMETER
DN
mm
SERVICE PIPE DM
mm
25
32
40
50
65
80
100
125
150
200
250
300
ф33.7x2.3
ф42.4x2.6
ф48.3x2.6
ф60.3x2.9
ф76.1x2.9
ф88.9x3.2
ф114.3x3.6
ф139.7x3.6
ф168.3x4.0
ф219.1x4.5
ф273.0x5.0
ф323.9x5.6
DIAMETER
JACKET PIPE DP
mm
Series 1
Series 2
Series 3
90
110
125
110
125
140
110
125
140
125
140
160
140
160
180
160
180
200
200
225
250
225
250
280
250
280
315
315
355
400
400
450
500
450
500
560
HEIGHT
Н
mm
409
414
417
423
431
438
450
463
477
502
530
570
HOW TO ORDER
ААAА-DM/DNK
DNK - Nominal valve diameter in mm
DM - Outer service pipe diameter in mm
ААAА - Item
0511 - For Series 1 with HDPE jacket pipe
0512 - For Series 2 with HDPE jacket pipe
0513 - For Series 3 with HDPE jacket pipe
0521 - For Series 1 with spiral folded jacket pipe
0522 - For Series 2 with spiral folded jacket pipe
0523 - For Series 3 with spiral folded jacket pipe
0531 - For steam Series 1 with HDPE jacket pipe
0532 - For steam Series 2 with HDPE jacket pipe
0533 - For steam Series 3 with HDPE jacket pipe
0541 - For steam Series 1 with spiral folded jacket pipe
0542 - For steam Series 2 with spiral folded jacket pipe
0543 - For steam Series 2 with spiral folded jacket pipe
Remarks:
-The service pipe can be produced from carbonic or
stainless steel, copper, polyethylene or another material,
according to client's order.
- The cover pipe can be produced from polyethylene or
galvanized sheet iron respectively for underground and
above-ground installation.
- When the working fluid is steam, the heat insulation is
increased with an additional heat-resistant layer,
determined according to steam temperature.
- Dimensions may vary according to client's request.
- Valve dimensions: DN25, DN40 and DN50
Н
1200
4000 Plovdiv, 5 Dyakon Ilarion str
tel: (032) 635 542, fax: (032) 268 547
e-mail: [email protected]; www.installpipe.com
11
PRE-INSULATED STOP VALVES SERIES 1, 2 AND 3
Length L = 1.5 m
PRODUCER
INSTALL ENGINEERING SV LTD
NOMINAL DIAMETER
DN
mm
SERVICE PIPE DM
mm
25
32
40
50
65
80
100
125
150
200
250
300
ф33.7x2.6
ф42.4x2.6
ф48.3x2.6
ф60.3x2.9
ф76.1x2.9
ф88.9x3.2
ф114.3x3.6
ф139.7x3.6
ф168.3x4.0
ф219.1x4.5
ф273.0x5.0
ф323.9x5.6
DIAMETER
JACKET PIPE DP
mm
Series 1 Series 2 Series 3
90
110
125
110
125
140
110
125
140
125
140
160
140
160
180
160
180
200
200
225
250
225
250
280
250
280
315
315
355
400
400
450
500
450
500
560
HEIGHT
Н
mm
WIDTH
B
mm
480
485
495
500
505
515
525
545
565
585
625
665
110
110
110
110
110
110
125
125
125
160
160
160
HOW TO ORDER
ААAА-DM
DM - Outer service pipe diameter in mm
ААAА - Item
0561 - For Series 1 with HDPE jacket pipe
0562 - For Series 2 with HDPE jacket pipe
0563 - For Series 3 with HDPE jacket pipe
Remarks:
B
- The service pipe is produced from carbonic steel
P235GH/ W.nr. 1.0345 (~St. 37.0).
- Shaft - stainless steel AISI 316L.
- Ball - stainless steel AISI 304.
- Ring - PTFE reinforced carbon.
- Sealing - PTFE reinforced carbon.
- The cover pipe is produced from polyethylene for
underground installation.
- Dimensions may vary according to client's request.
Н
1500
4000 Plovdiv, 5 Dyakon Ilarion str
tel: (032) 635 542, fax: (032) 268 547
e-mail: [email protected]; www.installpipe.com
12
PRE-INSULATED ANCHOR POINTS SERIES 1, 2 AND 3
Length L = 2.0 m
PRODUCER
INSTALL ENGINEERING SV LTD
NOMINAL
DIAMETER DN
mm
SERVICE PIPE DM
mm
25
32
40
50
65
80
100
125
150
200
250
300
400
ф33.7x2.3
ф42.4x2.6
ф48.3x2.6
ф60.3x2.9
ф76.1x2.9
ф88.9x3.2
ф114.3x3.6
ф139.7x3.6
ф168.3x4.0
ф219.1x4.5
ф273.0x5.0
ф323.9x5.6
ф406.4x6.3
DIAMETER
JACKET PIPE DП
mm
mm
mm
Series 1
Series 2
Series 3
90
110
125
110
125
140
110
125
140
125
140
160
140
160
180
160
180
200
200
225
250
225
250
280
250
280
315
315
355
400
400
450
500
450
500
560
560
630
710
HEIGHT
H
mm
WIDTH
t
mm
STRESSED
AREA
cm2
200
220
220
240
280
300
350
400
450
550
650
700
850
25
25
25
25
25
30
30
30
30
35
40
40
40
191
243
243
289
452
392
565
765
875
1385
1730
1885
2560
HOW TO ORDER
ААAА-DM
DM - Outer service pipe diameter in mm
ААAА - Item
0571 - For Series 1 with HDPE jacket pipe
0572 - For Series 2 with HDPE jacket pipe
0573 - For Series 3 with HDPE jacket pipe
Remarks:
- The service pipe can be produced from carbonic or stainless steel,
copper, polyethylene or another material, according to client's order.
- The cover pipe can be produced from polyethylene or galvanized
sheet iron respectively for underground and above-ground
installation.
- When the working fluid is steam, the heat insulation is increased
with an additional heat-resistant layer, determined according to
steam temperature.
- Dimensions may vary according to client's request.
t
Н
2000
4000 Plovdiv, 5 Dyakon Ilarion str
tel: (032) 635 542, fax: (032) 268 547
e-mail: [email protected]; www.installpipe.com
13
PRE-INSULATED DOUBLE PIPES
Length L = 12 m
PRODUCER
INSTALL ENGINEERING SV LTD
DIAMETER
NOMINAL DIAMETER
2 х DN
mm
25
32
40
50
65
80
100
125
150
JACKET PIPE PIPE Dp
mm
140
160
160
200
225
250
315
400
450
STEEL PIPE DM
mm
ф33.7x2.3
ф42.4x2.6
ф48.3x2.6
ф60.3x2.9
ф76.1x2.9
ф88.9x3.2
ф114.3x3.6
ф139.7x3.6
ф168.3x4.0
WEIGHT
DISTANCE C
kg/m
7.1
9.1
9.6
13.1
16.5
20.7
30.7
41.5
51.0
mm
19
19
19
20
20
25
25
30
40
HOW TO ORDER
АААA-DМ
DМ - Outer service pipe diameter in mm
АААA - Item
0014 - For HDPE jacket pipe
0015 - For spiral folded jacket pipe
Remarks:
-The service pipe can be produced from
carbonic or stainless steel, copper,
polyethylene or another material, according to
client's order.
- The cover pipe can be produced from
polyethylene or galvanized sheet iron
respectively for underground and aboveground installation.
- Dimensions may vary according to client's
request.
12 m
Dp
DM
С
DM
4000 Plovdiv, 5 Dyakon Ilarion str
tel: (032) 635 542, fax: (032) 268 547
e-mail: [email protected]; www.installpipe.com
14
PRE-INSULATED CURVED DOUBLE PIPES
Length L = 12 m
Maximum bending angle Y = 35o
PRODUCER
INSTALL ENGINEERING SV LTD
DIAMETER
WEIGHT
NOMINAL
DIAMETER
2 х DN
STEEL PIPE
JACKET PIPE PIPE
mm
25
32
40
50
65
80
100
125
150
mm
ф33.7x2.3
ф42.4x2.6
ф48.3x2.6
ф60.3x2.9
ф76.1x2.9
ф88.9x3.2
ф114.3x3.6
ф139.7x3.6
ф168.3x4.0
mm
140
160
160
200
225
250
315
400
450
kg/m
7.1
9.1
9.6
13.1
16.5
20.7
30.7
41.5
51.0
HOW TO ORDER
АААA-DМ/Y
Y - Bending angle in degrees
DМ - Outer service pipe diameter in mm
АААA - Itam
0016 - For HDPE jacket pipe
0017 - For spiral folded jacket pipe
Remarks:
- The service pipe can be produced from
carbonic or stainless steel, copper,
polyethylene or another material, according
to client's order.
- The cover pipe can be produced from
polyethylene or galvanized sheet iron
respectively for underground and aboveground installation.
- Dimensions may vary according to client's
request.
Y
4000 Plovdiv, 5 Dyakon Ilarion str
tel: (032) 635 542, fax: (032) 268 547
e-mail: [email protected]; www.installpipe.com
15
PRE-INSULATED BENDS DOUBLE PIPE
Bending angle Y=90, 105, 120, 135, 150 and 165 degrees and upon request
PRODUCER
INSTALL ENGINEERING SV LTD
NOMINAL DIAMETER
2 х DN
STEEL PIPE
mm
25
32
40
50
65
80
100
125
150
mm
ф33.7x2.3
ф42.4x2.6
ф48.3x2.6
ф60.3x2.9
ф76.1x2.9
ф88.9x3.2
ф114.3x3.6
ф139.7x3.6
ф168.3x4.0
DIAMETER
JACKET PIPE PIPE
mm
140
160
160
200
225
250
315
400
450
LENGTH
L
mm
1000
1000
1000
1000
1000
1000
1000
1000
1000
HOW TO ORDER
ААAА-DМ/Y
Y - Bending angle in degrees
DМ - Outer service pipe diameter in mm
АААA - Item
0114 - For HDPE jacket pipe
0115 - For spiral folded jacket pipe
Remarks:
- The service pipe can be produced from
carbonic or stainless steel, copper, polyethylene
or another material, according to client's order.
- The cover pipe can be produced from
polyethylene or galvanized sheet iron
respectively for underground and above-ground
installation.
- Dimensions may vary according to client's
request.
L
Y
L
4000 Plovdiv, 5 Dyakon Ilarion str
tel: (032) 635 542, fax: (032) 268 547
e-mail: [email protected]; www.installpipe.com
16
PRE-INSULATED T-PIECES DOUBLE PIPE
Deviation angle 90 degrees
PRODUCER
INSTALL ENGINEERING SV LTD
NOMINAL DIAMETER
MAIN PIPE DNM
BRANCH PIPE DNO
mm
mm
25-100
25-100
125-150
125-150
LENGTH
L1
mm
1200
1500
L2
mm
700
700
HOW TO ORDER
ААAА-DNM/DNO
DNО - Branch service pipe nominal diameter in mm
DNM - Main service pipe nominal diameter in mm
АААA - Item
0314 - For HDPE jacket pipe
0315 - For spiral folded jacket pipe
Remarks:
L2
L1
- The service pipe can be produced from carbonic
or stainless steel, copper, polyethylene or another
material, according to client's order.
- The cover pipe can be produced from
polyethylene or galvanized sheet iron respectively
for underground and above-ground installation.
- Dimensions may vary according to client's request.
- The branch pipe diameter cannot exceed the
diameter of the service pipe.
4000 Plovdiv, 5 Dyakon Ilarion str
tel: (032) 635 542, fax: (032) 268 547
e-mail: [email protected]; www.installpipe.com
17
TRANSITION UNITS SINGLE/DOUBLE PIPE
PRODUCER
INSTALL ENGINEERING SV LTD
DIAMETER
NOMINAL DIAMETER
2 х DN
mm
25
32
40
50
65
80
100
125
150
SERVICE PIPE DM
mm
ф33.7x2.3
ф42.4x2.6
ф48.3x2.6
ф60.3x2.9
ф76.1x2.9
ф88.9x3.2
ф114.3x3.6
ф139.7x3.6
ф168.3x4.0
JACKET PIPE DE/Dp
mm
90/140
110/160
110/160
125/200
140/225
160/250
200/315
200/400
225/450
LENGTH L
DISTANCE C
mm
1600
1600
1600
1600
1600
1800
1800
2000
2100
mm
310
330
330
340
360
380
475
500
530
HOW TO ORDER
АААA-DМ
DМ - Outer service pipe diameter in mm
ААAА - Item
0580 - For HDPE jacket pipe
0581 - For spiral folded jacket pipe
Remarks:
- The service pipe can be produced from
carbonic or stainless steel, copper, polyethylene
or another material, according to client's order.
- The cover pipe can be produced from
polyethylene or galvanized sheet iron
respectively for underground and above-ground
installation.
- Dimensions may vary according to client's
request.
L
Dp
С
DЕ
4000 Plovdiv, 5 Dyakon Ilarion str
tel: (032) 635 542, fax: (032) 268 547
e-mail: [email protected]; www.installpipe.com
18
PRE-INSULATED AIR RELEASE/DRAINAGE UNITS DOUBLE PIPE
Length L = 1.2 m
PRODUCER
NOMINAL DIAMETER
2 x DN
mm
25
32
40
50
65
80
100
125
150
INSTALL ENGINEERING SV LTD
DIAMETER
SERVICE PIPE
mm
ф33.7x2.3
ф42.4x2.6
ф48.3x2.6
ф60.3x2.9
ф76.1x2.9
ф88.9x3.2
ф114.3x3.6
ф139.7x3.6
ф168.3x4.0
JACKET PIPE
mm
140
160
160
200
225
250
315
400
450
HEIGHT
Н
mm
437
445
451
463
479
495
520
548
581
HOW TO ORDER
АААA-DM/DNK
DNK - Nominal valve diameter in mm
DM - Outer service pipe diameter in mm
АААA - Item
0514 - For HDPE jacket pipe
0515 - For spiral folded jacket pipe
Remarks:
- The service pipe can be produced from carbonic
or stainless steel, copper, polyethylene or another
material, according to client's order.
- The cover pipe can be produced from
polyethylene or galvanized sheet iron respectively
for underground and above-ground installation.
- Dimensions may vary according to client's
request.
- Valve dimensions: DN25, DN40 and DN50
Н
1200
4000 Plovdiv, 5 Dyakon Ilarion str
tel: (032) 635 542, fax: (032) 268 547
e-mail: [email protected]; www.installpipe.com
19
PRE-INSULATED VALVES DOUBLE PIPE
Distance between valves 200 mm
PRODUCER
INSTALL ENGINEERING SV LTD
NOMINAL DIAMETER
2 х DN
mm
25
32
40
50
65
80
100
125
150
SERVICE PIPE DM
mm
ф33.7x2.3
ф42.4x2.6
ф48.3x2.6
ф60.3x2.9
ф76.1x2.9
ф88.9x3.2
ф114.3x3.6
ф139.7x3.6
ф168.3x4.0
DIAMETER
JACKET PIPE DP
mm
140
160
160
200
225
250
315
400
450
HEIGHT
Н
mm
409
422
435
451
463
483
519
540
578
LENGTH
L
mm
1500
1500
1500
1500
1500
1500
1500
1500
1500
HOW TO ORDER
АААA-DM
DM - Outer service pipe diameter in mm
АААA - Item
0564 - For HDPE jacket pipe
0565 - For spiral folderd jacket pipe
Remarks:
- The service pipe can be produced from carbonic or
stainless steel, copper, polyethylene or another
material, according to client's order.
- The cover pipe can be produced from polyethylene
or galvanized sheet iron respectively for underground
and above-ground installation.
- Dimensions may vary according to client's request.
200
Н
L
4000 Plovdiv, 5 Dyakon Ilarion str
tel: (032) 635 542, fax: (032) 268 547
e-mail: [email protected]; www.installpipe.com
20
PRE-INSULATED ANCHOR POINTS DOUBLE PIPE
Length L = 2.0 m
PRODUCER
NOMINAL
DIAMETER DN
mm
25
32
40
50
65
80
100
125
150
INSTALL ENGINEERING SV LTD
SERVICE PIPE DM
mm
ф33.7x2.3
ф42.4x2.6
ф48.3x2.6
ф60.3x2.9
ф76.1x2.9
ф88.9x3.2
ф114.3x3.6
ф139.7x3.6
ф168.3x4.0
DIAMETER
JACKET PIPE DP
mm
140
160
160
200
225
250
315
400
450
HEIGHT
H
mm
250
300
300
300
350
400
450
550
650
WIDTH
t
mm
20
20
20
20
30
30
30
35
40
STRESSED
AREA
cm2
337
505
505
390
565
765
810
1120
1720
HOW TO ORDER
ААAА-DM
DM - Outer service pipe diameter in mm
АAАА - Item
0574 - For HDPE jacket pipe
0575 - For spiral folded jacket pipe
Remarks:
- The service pipe can be produced from carbonic or stainless
steel, copper, polyethylene or another material, according to
client's order.
- The cover pipe can be produced from polyethylene or galvanized
sheet iron respectively for underground and above-ground
installation.
- Dimensions may vary according to client's request.
t
Н
2000
4000 Plovdiv, 5 Dyakon Ilarion str
tel: (032) 635 542, fax: (032) 268 547
e-mail: [email protected]; www.installpipe.com
21
AXIAL COATED COMPENSATORS
Nominal pressure PN = 16 bar
PRODUCER
T-COMP Denmark
NOMINAL
DIAMETER
DN
mm
32
40
50
65
80
100
125
150
175
200
250
300
350
400
450
500
OUTER
DIAMETER
Du
mm
73.0
73.0
86.0
102.0
123.0
139.7
168.3
193.7
219.1
268.0
323.9
355.6
406.0
460.0
510.0
560.0
MAXIMUM
AXIAL FORCE
ELONGATION
∆L
mm
N/mm
100
63
100
57
100
71
100
77
100
124
125
105
125
108
125
120
125
126
125
152
125
203
125
241
125
265
125
404
125
434
125
482
LENGTH
L
mm
605
605
605
640
620
795
765
755
750
745
815
875
790
790
790
790
HOW TO ORDER
0600-DN/∆L
∆L - Maximum elongation in mm
DN - Nominal diameter in mm
Du
L
4000 Plovdiv, 5 Dyakon Ilarion str
tel: (032) 635 542, fax: (032) 268 547
e-mail: [email protected]; www.installpipe.com
22
AXIAL COATED COMPENSATORS
Nominal pressures PN = 16 и 25 bar
PRODUCER
T-COMP Denmark
NOMINAL
DIAMETER
DN
mm
32
40
50
65
80
100
125
150
175
200
250
300
350
400
450
500
600
OUTER DIAMETER
Du
mm
16 bar
73.0
73.0
86.0
102.0
123.0
139.7
168.3
193.7
219.1
268.0
323.9
355.6
406.0
460.0
510.0
560.0
675.0
25 bar
132
160
185
220
247
272
326
385
417
468
519
572
683
MAXIMUM
ELONGATION
∆L
mm
16 bar 25 bar
200
200
200
200
200
180
250
180
250
180
250
180
250
180
250
180
250
180
250
180
250
180
250
180
250
180
250
180
250
180
AXIAL FORCE
N/mm
16 bar
25 bar
32
29
36
38.5
62
136
53
119
54
133
60
146
63
180
76
203
102
201
121
312
133
313
202
306
217
344
241
288
289
431
LENGTH
L
mm
16 bar
1100
1100
1100
1350
1150
1450
1400
1400
1400
1350
1470
1600
1450
1450
1450
1450
1500
25 bar
1100
1100
1100
1100
1150
1200
1200
1200
1200
1200
1200
1200
1300
HOW TO ORDER
0604-DN-∆L-PN
PN - Nominal pressure in bar
∆L - Maximum elongation in mm
DN - Nominal diameter in mm
Du
L
4000 Plovdiv, 5 Dyakon Ilarion str
tel: (032) 635 542, fax: (032) 268 547
e-mail: [email protected]; www.installpipe.com
23
ONE-TIME AXIAL COATED COMPENSATORS
Nominal pressures PN = 16 и 25 bar
PRODUCER
T-COMP Denmark
NOMINAL
DIAMETER
DN
mm
25
32
40
50
65
80
100
125
150
175
200
250
300
350
400
450
500
600
OUTER DIAMETER
Du
mm
56.0
73.0
73.0
86.0
106.0
122.0
139.7
168.3
193.7
219.1
268.0
323.9
355.6
406.4
457.2
508.0
560.0
675.0
MAXIMUM
ELONGATION
∆L
mm
50
50
50
50
70
70
80
80
100
100
120
120
140
140
140
150
150
150
AXIAL FORCE
LENGTH
L
mm
275
275
275
275
335
345
390
400
475
475
515
515
660
650
650
660
660
690
N/mm
176
204
177
224
219
180
212
226
261
648
361
362
353
617
505
528
537
864
HOW TO ORDER
0601-DN-∆L-PN
PN - Nominal pressure in bar
∆L - Maximum elongation in mm
DN - Nominal diameter in mm
Du
L
4000 Plovdiv, 5 Dyakon Ilarion str
tel: (032) 635 542, fax: (032) 268 547
e-mail: [email protected]; www.installpipe.com
24
AXIAL COMPENSATORS
Nominal pressures PN = 10, 16 и 25 bar
PRODUCER
T-COMP Denmark
NOMINAL
DIAMETER
DN
mm
25
32
40
50
65
80
100
125
150
200
250
300
350
400
450
500
600
AXIAL FORCE
MAXIMUM
ELONGATION
∆L
mm
N/mm
10 bar 16 bar 25 bar 10 bar 16 bar 25 bar
10
10
10
127
127
236
10
10
10
146
146
236
20
20
15
204
204
252
25
20
20
172
208
381
30
30
15
130
233
310
35
35
20
184
203
320
35
35
25
94
234
328
35
35
25
233
233
442
40
40
30
151
247
441
40
40
30
173
259
574
55
40
30
174
323
631
55
40
30
310
383
748
55
45
35
393
445
685
55
45
30
366
715
1394
55
45
30
418
817
1568
55
45
30
465
908
1618
55
45
30
558 1089
2427
LENGTH
10 bar
175
180
235
245
220
240
200
245
220
235
260
265
285
305
265
265
265
L
mm
16 bar
175
180
235
225
235
230
245
245
230
245
245
245
270
310
275
275
275
25 bar
175
175
215
240
205
220
210
230
230
230
250
250
255
260
270
240
250
HOW TO ORDER
0602-DN-∆L-PN
PN - Nominal pressure in bar
∆L - Maximum elongation in mm
DN - Nominal diameter in mm
L
4000 Plovdiv, 5 Dyakon Ilarion str
tel: (032) 635 542, fax: (032) 268 547
e-mail: [email protected]; www.installpipe.com
25
AXIAL COMPENSATORS WITH FLANGES
Nominal pressures PN = 10, 16 и 25 bar
NOMINAL
DIAMETER
DN
mm
25
32
40
50
65
80
100
125
150
200
250
300
350
400
450
500
600
AXIAL FORCE
MAXIMUM
ELONGATION
∆L
mm
N/mm
10 bar 16 bar 25 bar 10 bar 16 bar 25 bar
10
10
10
127
127
236
10
10
10
146
146
236
20
20
15
204
204
252
25
20
20
172
208
381
30
30
15
130
233
310
35
35
20
184
203
320
35
35
25
94
234
328
35
35
25
233
233
442
40
40
30
151
247
441
40
40
30
173
259
574
55
40
30
174
323
631
55
40
30
310
383
748
55
45
35
393
445
685
55
45
30
366
715
1394
55
45
30
418
817
1568
55
45
30
465
908
1618
55
45
30
558 1089
2427
LENGTH
10 bar
90
95
145
160
140
160
125
170
145
165
195
200
225
250
225
225
240
L
mm
16 bar
130
140
200
195
205
210
230
240
220
245
265
280
315
360
325
335
345
25 bar
135
139
185
215
190
215
220
246
260
270
305
310
335
360
370
370
380
HOW TO ORDER
0603-DN-∆L-PN
PN - Nominal pressure in bar
∆L - Maximum elongation in mm
DN - Nominal diameter in mm
L
4000 Plovdiv, 5 Dyakon Ilarion str
tel: (032) 635 542, fax: (032) 268 547
e-mail: [email protected]; www.installpipe.com
26
SHRINKABLE CASINGS
Length 500 - 700 mm
PRODUCER
HDPE pipe
diameter
D
mm
63
75
90
110
125
140
160
180
200
225
250
280
315
355
400
450
500
520
560
630
670
710
800
900
1000
SALLING PLAST AS Denmark
Casing inner
diameter
DВ
mm
77
89
103
125
140
156
177
197
218
244
269
300
336
377
425
474
530
556
590
660
713
749
838
949
1060
Length L
Casing wall
thickness
w. mastix
mm
500 - 700
500 - 700
500 - 700
500 - 700
500 - 700
500 - 700
500 - 700
500 - 700
500 - 700
500 - 700
500 - 700
500 - 700
500 - 700
500 - 700
500 - 700
500 - 700
500 - 700
500 - 700
500 - 700
500 - 700
500 - 700
500 - 700
500 - 700
500 - 700
500 - 700
mm
3,0
3,0
3,0
3,0
3,0
3,0
3,0
3,5
3,5
3,5
4,0
4,0
4,5
5,0
5,5
6,5
7,5
7,8
8,8
9,8
12,3
11,1
12,5
14,0
15,6
Welded
mm
500 - 700
500 - 700
500 - 700
500 - 700
500 - 700
500 - 700
500 - 700
500 - 700
500 - 700
500 - 700
500 - 700
500 - 700
500 - 700
500 - 700
500 - 700
500 - 700
500 - 700
500 - 700
500 - 700
500 - 700
500 - 700
500 - 700
500 - 700
500 - 700
500 - 700
HOW TO ORDER
АААА-D/L
L - Casing length
D - Outer diameter of HDPE pipe in mm
АААА - Item
0701 - Shrinkable casing w. mastix
0723 - Welded casing
DВ
Remarks:
Their purpose is to link two preinsulated welded pipe ends,
ensuring the tightness of
connections. Installation is through
heating, which causes the casings to
shrink. The space between the
casing and the service pipe is filled
with polyurethane foam.
L
4000 Plovdiv, 5 Dyakon Ilarion str
tel: (032) 635 542, fax: (032) 268 547
e-mail: [email protected]; www.installpipe.com
27
SHRINKABLE OPEN CASINGS
Length - L = 450, 650, 760 and 900 mm
PRODUCER
SALLING PLAST AS Denmark
HDPE pipe diameter D
mm
90
110
125
140
160
180
200
225
250
280
315
355
400
450
500
560
630
HOW TO ORDER
0703-D/L
L - Casing length in mm
D - Outside diameter of HDPE pipe in mm
DВ
Remarks:
Their purpose is to link two preinsulated welded pipe ends, ensuring
the tightness of connections. The open
end of the casings has self-adhesive
coating. Installation is through heating,
which causes the casings to shrink.
The space between the casing and the
service pipe is filled with polyurethane
foam.
L
4000 Plovdiv, 5 Dyakon Ilarion str
tel: (032) 635 542, fax: (032) 268 547
e-mail: [email protected]; www.installpipe.com
28
SHRINKABLE BAND
Width - W = 150, 225, 650, 760 and 900 mm
Length L = 15 и 30 m
PRODUCER
SALLING PLAST AS Denmark
HOW TO ORDER
0713-W/L
L - Band length in m
W - Band width in mm
W
Remarks:
Their purpose is to link the ends of
the casing with the HDPE pipe.
Installation is through heating,
which causes the casings to
shrink.
L
4000 Plovdiv, 5 Dyakon Ilarion str
tel: (032) 635 542, fax: (032) 268 547
e-mail: [email protected]; www.installpipe.com
29
ORDINARY CASINGS
Length - 500, 600, 700 mm
PRODUCER
SALLING PLAST AS Denmark
HDPE pipe diameter
D
mm
63
75
90
110
125
140
160
180
200
225
250
280
315
355
400
450
500
560
630
710
800
900
1000
Casing inner diameter
DВ
mm
69
84
96
116
132
149
170
189
209
237
263
290
329
370
413
464
517
578
648
733
827
929
1028
Casing wall thickness
mm
3,0
3,0
3,0
3,0
3,0
3,0
3,5
3,5
3,5
4,0
4,0
4,5
5,0
5,5
6,5
7,5
8,0
8,5
9,0
11,1
12,5
14,0
15,6
HOW TO ORDER
0704-D/L
L - Casing length in mm
D - HDPE pipe outside diameter in mm
DВ
Remarks:
Their purpose is to link two preinsulated welded pipe ends,
ensuring the tightness of
connections. The space between
the casing and the service pipe is
filled with polyurethane foam.
L
4000 Plovdiv, 5 Dyakon Ilarion str
tel: (032) 635 542, fax: (032) 268 547
e-mail: [email protected]; www.installpipe.com
30
SHRINKABLE REDUCTION CASINGS
Length L = 700 mm, 900 mm
PRODUCER
SALLING PLAST AS Denmark
Small HDPE pipe
diameter DB1
Large HDPE pipe
diameter DB2
Inner diameter
casing DB1/DB2
mm
63
mm
75
90
110
125
140
90
110
125
140
160
110
125
140
160
180
125
140
160
180
200
140
160
180
200
225
160
180
200
225
250
180
200
225
250
280
mm
77/89
77/103
77/125
77/140
77/156
89/103
89/125
89/140
89/156
89/177
103/125
103/140
103/156
103/177
103/197
125/140
125/156
125/177
125/197
125/218
140/156
140/177
140/197
140/218
140/244
156/177
156/197
156/218
156/244
156/269
177/197
177/218
177/244
177/269
177/300
75
90
110
125
140
160
HOW TO ORDER
0705-DB2/DB1/L
Small HDPE pipe Large HDPE pipe
diameter DB1
diameter DB2
mm
180
mm
200
225
250
280
315
225
250
280
315
355
250
280
315
280
315
355
400
315
355
400
355
400
450
400
450
450
500
500
560
560
630
710
800
900
1000
200
225
250
280
315
355
400
450
500
560
630
710
800
900
Inner diameter
casing DB1/DB2
mm
197/218
197/244
197/269
197/300
197/336
218/244
218/269
218/300
218/336
218/377
244/269
244/300
244/336
269/300
269/336
269/377
269/425
300/336
300/377
300/425
336/377
336/425
336/474
377/425
377/474
425/474
425/530
476/530
474/590
530/590
590/660
660/749
749/838
838/949
949/1060
Casing length in mm
DB1 - Small HDPE pipe diameter in mm
DB2 - Large HDPE pipe diameter in mm
DB2
DB1
Remarks:
Their purpose is to link two preinsulated welded pipe ends with
different sizes, ensuring the tightness
of connections.Installation is through
heating, which causes the casings to
shrink. The space between the casing
and the service pipe is filled with
polyurethane foam.
L
4000 Plovdiv, 5 Dyakon Ilarion str
tel: (032) 635 542, fax: (032) 268 547
e-mail: [email protected]; www.installpipe.com
31
END CASINGS
Length L 500 mm
PRODUCER SALLING PLAST AS Denmark
HDPE pipe diameter
D
mm
63
75
90
110
125
140
160
180
200
225
250
280
315
355
400
450
500
560
630
710
800
900
1000
Casing inner diameter
DВ
mm
69
84
96
116
132
149
170
189
209
237
263
290
329
370
413
464
517
578
648
733
827
929
1028
Casing wall thickness
mm
3,0
3,0
3,0
3,0
3,0
3,0
3,5
3,5
3,5
4,0
4,0
4,5
5,0
5,5
6,5
7,5
8,0
8,5
9,0
11,1
12,5
14,0
15,6
HOW TO ORDER
0706-D/500
D - Outer diameter of HDPE pipe in mm
DВ
Remarks:
Their purpose is to fully close the
end of a HDPE pipe, ensuring
tightness of closing. Installation is
through heating, which causes the
casings to shrink. The space
between the casing and the service
pipe is filled with polyurethane foam.
500
4000 Plovdiv, 5 Dyakon Ilarion str
tel: (032) 635 542, fax: (032) 268 547
e-mail: [email protected]; www.installpipe.com
32
END CAPS
Lengths L = 500 and 700 mm
PRODUCER
SALLING PLAST AS Denmark
HDPE pipe
diameter Dp
Service pipe
diameter DМ
Minimum service
pipe diameter
mm
110
125
140
mm
48
60
60
76
76
89
76
89
89
114
114
140
114
140
168
140
168
194
168
219
219
219
273
273
324
273
324
356
356
406
mm
48
55
60
60
65
65
70
70
85
85
100
100
110
110
110
125
125
125
140
140
150
160
160
190
190
210
210
210
220
220
160
180
200
225
250
280
315
355
400
450
500
520
Small HDPE pipe Large HDPE pipe Minimum service
diameter DB1
diameter DB2
pipe diameter
mm
560
630
670
710
780
800
900
1000
1100
1200
mm
324
356
406
457
356
406
457
508
406
457
508
406
457
508
558
559
610
457
508
559
510
508
559
610
711
610
711
813
813
914
914
1016
mm
210
210
210
210
245
245
245
245
250
250
250
265
265
265
265
290
290
300
300
300
300
335
335
335
335
375
375
375
405
405
440
440
HOW TO ORDER
0707-DП/DМ/L
L - Cap length in mm
DB1 - Small HDPE pipe diameter in mm
DB2 - Large HDPE pipe diameter in mm
Dp
DМ
Remarks:
Their purpose is to fully close the end
of a HDPE pipe to the service pipe
surface, ensuring the tightness of the
closing. Installation is through heating,
which causes the casings to shrink.
L
4000 Plovdiv, 5 Dyakon Ilarion str
tel: (032) 635 542, fax: (032) 268 547
e-mail: [email protected]; www.installpipe.com
33
"О"- RINGS
PRODUCER
SALLING PLAST AS Denmark
HDPE pipe diameter D
63
75
90
110
125
140
160
180
200
225
250
280
315
355
400
450
500
560
630
710
800
900
1000
1100
1200
HOW TO ORDER
0708-D
D - Outside diameter of HDPE pipe in mm
Remarks:
Their purpose is to close the space between the
HDPE pipe and walls, concrete channels, etc. in
building constructions.
D
4000 Plovdiv, 5 Dyakon Ilarion str
tel: (032) 635 542, fax: (032) 268 547
e-mail: [email protected]; www.installpipe.com
3534