STRAIGHT PIPES SERIES 1 Lenght L = 12 m PRODUCER INSTALL ENGINEERING SV LTD DIAMETER NOMINAL DIAMETER DN mm 20 25 32 40 50 65 80 100 125 150 200 250 300 350 400 450 500 600 700 800 JACKET PIPE DP mm 90 90 110 110 125 140 160 200 225 250 315 400 450 500 560 560 630 710 800 900 SERVICE PIPE DM mm ф26.9x2.0 ф33.7x2.3 ф42.4x2.6 ф48.3x2.6 ф60.3x2.9 ф76.1x2.9 ф88.9x3.2 ф114.3x3.6 ф139.7x3.6 ф168.3x4.0 ф219.1x4.5 ф273.0x5.0 ф323.9x5.6 ф355.6x5.6 ф406.4x6.3 ф457.0x6.3 ф508.0x6.3 ф610.0x7.1 ф711.0x8.8 ф813.0x8.8 WEIGHT WATER CONTENT kg/m 2.5 3.1 4.3 4.6 6.1 7.4 9.4 13.6 16.6 21.5 31.9 46.3 60.0 68.3 86.9 91.6 105,4 138.0 190,2 222.0 l/m 0.4 0.6 1.1 1.5 2.3 3.9 5.3 9.0 13.8 20.2 34.7 54.3 76.8 93.1 122.0 155.0 193.0 277.0 378.0 497.0 HOW TO ORDER: АААA-DМ DМ - Outer service pipe diameter in mm ААAА - Item 0011 - For HDPE jacket pipe 0021 - For spiral folded jacket pipe 0031 - For steam service pipe with HDPE jacket pipe 0041 - For steam service pipe with spiral folded jacket pipe Remarks: - The service pipe can be produced from carbonic or stainless steel, copper, polyethylene or another material, according to client's order. - The cover pipe can be produced from polyethylene or galvanized sheet iron respectively for underground and above-ground installation. - When the working fluid is steam, the heat insulation is increased with an additional heat-resistant layer, determined according to steam temperature. - Dimensions may vary according to client's request. 12 m Dp DM 4000 Plovdiv, 5 Dyakon Ilarion str tel: (032) 635 542, fax: (032) 268 547 e-mail: [email protected]; www.installpipe.com 1 STRAIGHT PIPES SERIES 2 Lenght L = 12 m PRODUCER NOMINAL DIAMETER DN mm 20 25 32 40 50 65 80 100 125 150 200 250 300 350 400 450 500 600 700 800 INSTALL ENGINEERING SV LTD DIAMETER JACKET PIPE DP mm 110 110 125 125 140 160 180 225 250 280 355 450 500 560 630 630 710 800 900 1000 SERVICE PIPE DM mm ф26.9x2.0 ф33.7x2.3 ф42.4x2.6 ф48.3x2.6 ф60.3x2.9 ф76.1x2.9 ф88.9x3.2 ф114.3x3.6 ф139.7x3.6 ф168.3x4.0 ф219.1x4.5 ф273.0x5.0 ф323.9x5.6 ф355.6x5.6 ф406.4x6.3 ф457.0x6.3 ф508.0x6.3 ф610.0x7.1 ф711.0x8.8 ф813.0x8.8 WEIGHT WATER CONTENT kg/m 3.0 3.5 4.6 5.0 6.5 8.0 10.1 14.8 17.7 21.5 35.1 51.1 65.5 75.7 96.3 101.0 118.0 153.6 210.0 246.0 l/m 0.4 0.6 1.1 1.5 2.3 3.9 5.3 9.0 13.8 20.2 34.7 54.3 76.8 93.1 122.0 155.0 193.0 277.0 378.0 497.0 HOW TO ORDER: АААA-DМ DМ - Outer service pipe diameter in mm АААA - Item 0012 - For HDPE jacket pipe 0022 - For spiral folded jacket pipe 0032 - For steam service pipe with HDPE jacket pipe 0042 - For steam service pipe with spiral folded jacket pipe Remarks: - The service pipe can be produced from carbonic or stainless steel, copper, polyethylene or another material, according to client's order. - The cover pipe can be produced from polyethylene or galvanized sheet iron respectively for underground and above-ground installation. - When the working fluid is steam, the heat insulation is increased with an additional heat-resistant layer, determined according to steam temperature. - Dimensions may vary according to client's request. 12 m Dp DM 4000 Plovdiv, 5 Dyakon Ilarion str tel: (032) 635 542, fax: (032) 268 547 e-mail: [email protected]; www.installpipe.com 2 STRAIGHT PIPES SERIES 3 Lenght L = 12 m PRODUCER INSTALL ENGINEERING SV LTD DIAMETER NOMINAL DIAMETER DN mm 20 25 32 40 50 65 80 100 125 150 200 250 300 350 400 450 500 600 700 JACKET PIPE DP mm 125 125 140 140 160 180 200 250 280 315 400 500 560 630 710 710 800 900 1000 SERVICE PIPE DM mm ф26.9x2.0 ф33.7x2.3 ф42.4x2.6 ф48.3x2.6 ф60.3x2.9 ф76.1x2.9 ф88.9x3.2 ф114.3x3.6 ф139.7x3.6 ф168.3x4.0 ф219.1x4.5 ф273.0x5.0 ф323.9x5.6 ф355.6x5.6 ф406.4x6.3 ф457.0x6.3 ф508.0x6.3 ф610.0x7.1 ф711.0x8.8 WEIGHT WATER CONTENT kg/m 3.3 3.9 5.0 5.4 7.1 8.7 10.9 16.2 19.9 25.7 39.0 46.3 76.9 85.1 108.8 113.5 133.6 173.0 231.8 l/m 0.4 0.6 1.1 1.5 2.3 3.9 5.3 9.0 13.8 20.2 34.7 54.3 76.8 93.1 122.0 155.0 193.0 277.0 378.0 HOW TO ORDER: ААAА-DМ DМ - Outer service pipe diameter in mm АААA - Item 0013 - For HDPE jacket pipe 0023 - For spiral folded jacket pipe 0033 - For steam service pipe with HDPE jacket pipe 0043 - For steam service pipe with spiral folded jacket pipe Remarks: - The service pipe can be produced from carbonic or stainless steel, copper, polyethylene or another material, according to client's order. - The cover pipe can be produced from polyethylene or galvanized sheet iron respectively for underground and above-ground installation. - When the working fluid is steam, the heat insulation is increased with an additional heat-resistant layer, determined according to steam temperature. - Dimensions may vary according to client's request. 12 m Dp DM 4000 Plovdiv, 5 Dyakon Ilarion str tel: (032) 635 542, fax: (032) 268 547 e-mail: [email protected]; www.installpipe.com 3 PRE-INSULATED CURVED PIPES SERIES 1, 2 AND 3 Lenght L = 12 m PRODUCER DN INSTALL ENGINEERING SV LTD DIAMETER mm SERVICE PIPE mm 20 25 32 40 50 65 80 100 125 150 200 250 300 350 400 ф26.9x2.0 ф33.7x2.3 ф42.4x2.6 ф48.3x2.6 ф60.3x2.9 ф76.1x2.9 ф88.9x3.2 ф114.3x3.6 ф139.7x3.6 ф168.3x4.0 ф219.1x4.5 ф273.0x5.0 ф323.9x5.6 ф355.6x5.6 ф406.4x6.3 MAXIMUM BENDING ANGLE Y WEIGHT JACKET PIPE mm Series 1 Series 2 Series 3 Series 1 90 110 125 2.5 90 110 125 3.1 110 125 140 4.3 110 125 140 4.6 125 140 160 6.1 140 160 180 7.4 160 180 200 9.4 200 225 250 13.6 225 250 280 16.6 250 280 315 21.5 315 355 400 31.9 400 450 500 46.3 450 500 560 60.0 500 560 630 68.3 560 630 710 86.9 kg/m Series 2 3.0 3.5 4.6 5.0 6.5 8.0 10.1 14.8 17.7 21.5 35.1 51.1 65.5 75.7 96.3 Series 3 Series 1 Series 2 Series 3 35 O 35 O 35 O 3.3 O O 35 35 35 O 3.9 O O 35 35 35 O 5.0 O O 35 35 35 O 5.4 O O 35 35 35 O 7.1 O O 35 35 35 O 8.7 O O 35 35 35 O 10.9 O O 35 35 35 O 16.2 O O 35 35 35 O 19.9 O O 35 35 35 O 25.7 O O 25 25 25 O 39.0 O O 20 20 20 O 46.3 O O 15 15 15 O 76.9 O O 15 15 15 O 85.1 O O 15 15 15 O 108.8 HOW TO ORDER: АААA-DМ/Y Y - Bending angle in degrees DМ - Outer service pipe diameter in mm ААAА - Item 0051 - For Series 1 0052 - For Series 2 0053 - For Series 3 Remarks: - The service pipe can be produced from carbonic or stainless steel, copper, polyethylene or another material, according to client's order. - The cover pipe can be produced from polyethylene or galvanized sheet iron respectively for underground and above-ground installation. - When the working fluid is steam, the heat insulation is increased with an additional heat-resistant layer, determined according to steam temperature. - Dimensions may vary according to client's request. Y 4000 Plovdiv, 5 Dyakon Ilarion str tel: (032) 635 542, fax: (032) 268 547 e-mail: [email protected]; www.installpipe.com 4 PRE-INSULATED BENDS SERIES 1, 2 AND 3 Bending angle Y=90, 105, 120, 135, 150 and 165 degrees and upon request PRODUCER INSTALL ENGINEERING SV LTD NOMINAL DIAMETER DN mm 20 25 32 40 50 65 80 100 125 150 200 250 300 350 400 450 500 600 700 800 DIAMETER JACKET PIPE SERVICE PIPE mm ф26.9x2.0 ф33.7x2.6 ф42.4x2.6 ф48.3x2.6 ф60.3x2.9 ф76.1x2.9 ф88.9x3.2 ф114.3x3.6 ф139.7x3.6 ф168.3x4.0 ф219.1x4.5 ф273.0x5.0 ф323.9x5.6 ф355.6x5.6 ф406.4x6.3 ф457.0x6.3 ф508.0x6.3 ф610.0x7.1 ф711.0x8.8 ф813.0x8.8 LENGTH mm Series 2 110 110 125 125 140 160 180 225 250 280 355 450 500 560 630 630 710 800 900 1000 Series 1 90 90 110 110 125 140 160 200 225 250 315 400 450 500 560 560 630 710 800 900 HOW TO ORDER: ААAА-DМ/Y Y - Bending angle in degrees DМ - Outer service pipe diameter in mm АААA - Item 0111 - For Series 1 with HDPE jacket pipe 0112 - For Series 2 with HDPE jacket pipe 0113 - For Series 3 with HDPE jacket pipe 0121 - For Series 1 with spiral folded jacket pipe 0122 - For Series 2 with spiral folded jacket pipe 0123 - For Series 3 with spiral folded jacket pipe L mm Series 3 125 125 140 140 160 180 200 250 280 315 400 500 560 630 710 710 800 900 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1200 1200 1200 1200 1200 1600 1600 1600 1700 1850 0131 - For steam Series 1 with HDPE jacket pipe 0132 - For steam Series 2 with HDPE jacket pipe 0133 - For steam Series 3 with HDPE jacket pipe 0141 - For steam Series 1 with spiral folded jacket pipe 0142 - For steam Series 2 with spiral folded jacket pipe 0143 - For steam Series 2 with spiral folded jacket pipe Remarks: - The service pipe can be produced from carbonic or stainless steel, copper, polyethylene or another material, according to client's order. - The cover pipe can be produced from polyethylene or galvanized sheet iron respectively for underground and above-ground installation. - When the working fluid is steam, the heat insulation is increased with an additional heat-resistant layer, determined according to steam temperature. - Dimensions may vary according to client's request. L Y L 4000 Plovdiv, 5 Dyakon Ilarion str tel: (032) 635 542, fax: (032) 268 547 e-mail: [email protected]; www.installpipe.com 5 BEND SHELLS Bending angle Y = 90, 120, 135 and 150 degrees and upon request PRODUCER INSTALL ENGINEERING SV LTD POLYETHYLENE PIPE DIAMETER D LENGTH L 90 110 125 140 160 180 200 250 mm 360 370 380 420 440 470 540 700 HOW TO ORDER 0150-D/Y Y - Bending angle in degrees D - Outer diameter of polyethylene pipe in mm Remarks: - The shell, which is produced from polyethylene, is consisted of two parts, joined by bolts. - After installation, the space between the shell and the service pipe is filled with polyurethane foam. L Y L D 4000 Plovdiv, 5 Dyakon Ilarion str tel: (032) 635 542, fax: (032) 268 547 e-mail: [email protected]; www.installpipe.com 6 PRE-INSULATED T-PIECES SERIES 1, 2 AND 3 Deviation angle: 90 degrees PRODUCER INSTALL ENGINEERING SV LTD NOMINAL DIAMETER MAIN PIPE DNM BRANCH PIPE DNO mm mm 25-200 25-80 100-200 100-200 250-800 25-80 250-800 100-200 250-800 250-600 LENGTH L1 mm 1200 1500 1200 1500 1800 L2 mm 1000 1000 1200 1200 1500 HOW TO ORDER АААA-DNM/DNO DNО - Branch service pipe nominal diameter in mm DNM - Main service pipe nominal diameter in mm АААA - Item 0211 - For Series 1 with HDPE jacket pipe 0231 - For steam Series 1 with HDPE jacket pipe 0212 - For Series 2 with HDPE jacket pipe 0232 - For steam Series 2 with HDPE jacket pipe 0213 - For Series 3 with HDPE jacket pipe 0233 - For steam Series 3 with HDPE jacket pipe 0221 - For Series 1 with spiral folded jacket pipe 0241 - For steam Series 1 with spiral folded jacket pipe 0222 - For Series 2 with spiral folded jacket pipe 0242 - For steam Series 2 with spiral folded jacket pipe 0223 - For Series 3 with spiral folded jacket pipe 0243 - For steam Series 2 with spiral folded jacket pipe Remarks: L2 -The service pipe can be produced from carbonic or stainless steel, copper, polyethylene or another material, according to client's order. - The cover pipe can be produced from polyethylene or galvanized sheet iron respectively for underground and above-ground installation. - When the working fluid is steam, the heat insulation is increased with an additional heat-resistant layer, determined according to steam temperature. - Dimensions may vary according to client's request. - The branch pipe diameter cannot exceed the diameter of the service pipe. L1 4000 Plovdiv, 5 Dyakon Ilarion str tel: (032) 635 542, fax: (032) 268 547 e-mail: [email protected]; www.installpipe.com 7 PERPENDICULAR T-PIECES SERIES 1, 2 AND 3 Deviation angle 90 degrees Length - Main pipe 1.2 m, branch pipe 0.7 m PRODUCER INSTALL ENGINEERING SV LTD NOMINAL DIAMETER MAIN PIPE DNM mm 25-200 BRANCH PIPE DNO mm 25-200 HOW TO ORDER АААA-DNM/DNO DNО - Branch service pipe nominal diameter in mm DNM - Main service pipe nominal diameter in mm АААA - Item 0311 - For Series 1 with HDPE jacket pipe 0312 - For Series 2 with HDPE jacket pipe 0313 - For Series 3 with HDPE jacket pipe 0321 - For Series 1 with spiral folded jacket pipe 0322 - For Series 2 with spiral folded jacket pipe 0323 - For Series 3 with spiral folded jacket pipe 0331 - For steam Series 1 with HDPE jacket pipe 0332 - For steam Series 2 with HDPE jacket pipe 0333 - For steam Series 3 with HDPE jacket pipe 0341 - For steam Series 1 with spiral folded jacket pipe 0342 - For steam Series 2 with spiral folded jacket pipe 0343 - For steam Series 2 with spiral folded jacket pipe Remarks: 700 1200 -The service pipe can be produced from carbonic or stainless steel, copper, polyethylene or another material, according to client's order. - The cover pipe can be produced from polyethylene or galvanized sheet iron respectively for underground and above-ground installation. - When the working fluid is steam, the heat insulation is increased with an additional heat-resistant layer, determined according to steam temperature. - Dimensions may vary according to client's request. - The branch pipe diameter cannot exceed the diameter of the service pipe. 4000 Plovdiv, 5 Dyakon Ilarion str tel: (032) 635 542, fax: (032) 268 547 e-mail: [email protected]; www.installpipe.com 8 PARALLEL T-PIECES SERIES 1, 2 AND 3 PRODUCER MAIN PIPE DNM mm 25-400 125-500 INSTALL ENGINEERING SV LTD NOMINAL DIAMETER BRANCH PIPE DNO mm 25-100 125-300 LENGTH L mm 1200 1500 HOW TO ORDER АAАА-DNM/DNO DNО - Branch service pipe nominal diameter in mm DNM - Main service pipe nominal diameter in mm АAАА - Item 0411 - For Series 1 with HDPE jacket pipe 0412 - For Series 2 with HDPE jacket pipe 0413 - For Series 3 with HDPE jacket pipe 0421 - For Series 1 with spiral folded jacket pipe 0422 - For Series 2 with spiral folded jacket pipe 0423 - For Series 3 with spiral folded jacket pipe 0431 - For steam Series 1 with HDPE jacket pipe 0432 - For steam Series 2 with HDPE jacket pipe 0433 - For steam Series 3 with HDPE jacket pipe 0441 - For steam Series 1 with spiral folded jacket pipe 0442 - For steam Series 2 with spiral folded jacket pipe 0443 - For steam Series 2 with spiral folded jacket pipe Remarks: - The service pipe can be produced from carbonic or stainless steel, copper, polyethylene or another material, according to client's order. - The cover pipe can be produced from polyethylene or galvanized sheet iron respectively for underground and above-ground installation. - When the working fluid is steam, the heat insulation is increased with an additional heat-resistant layer, determined according to steam temperature. - Dimensions may vary according to client's request. - The branch pipe diameter cannot exceed the diameter of the service pipe. 150 L 4000 Plovdiv, 5 Dyakon Ilarion str tel: (032) 635 542, fax: (032) 268 547 e-mail: [email protected]; www.installpipe.com 9 T-PIECES SHELLS Deviation angle 90 degrees Main pipe length = 450 mm PRODUCER INSTALL ENGINEERING SV LTD NOMINAL DIAMETER MAIN PIPE DNM BRANCH PIPE DNO mm mm 125 110 140 125 160 125 140 180 125 140 160 200 160 180 LENGTH L2 mm 190 200 220 210 300 215 220 230 240 HOW TO ORDER 0450-DNM/DNO DNО - Branch service pipe nominal diameter in mm DNM - Main service pipe nominal diameter in mm L2 450 Remarks: - The shell, which is produced from polyethylene, is consisted of two parts, joined by bolts. - After installation, the space between the shell and the service pipe is filled with polyurethane foam. DNM 4000 Plovdiv, 5 Dyakon Ilarion str tel: (032) 635 542, fax: (032) 268 547 e-mail: [email protected]; www.installpipe.com 10 PRE-INSULATED AIR RELEASE/DRAINAGE UNITS SERIES 1, 2 AND 3 Length L = 1.2 m PRODUCER INSTALL ENGINEERING SV LTD NOMINAL DIAMETER DN mm SERVICE PIPE DM mm 25 32 40 50 65 80 100 125 150 200 250 300 ф33.7x2.3 ф42.4x2.6 ф48.3x2.6 ф60.3x2.9 ф76.1x2.9 ф88.9x3.2 ф114.3x3.6 ф139.7x3.6 ф168.3x4.0 ф219.1x4.5 ф273.0x5.0 ф323.9x5.6 DIAMETER JACKET PIPE DP mm Series 1 Series 2 Series 3 90 110 125 110 125 140 110 125 140 125 140 160 140 160 180 160 180 200 200 225 250 225 250 280 250 280 315 315 355 400 400 450 500 450 500 560 HEIGHT Н mm 409 414 417 423 431 438 450 463 477 502 530 570 HOW TO ORDER ААAА-DM/DNK DNK - Nominal valve diameter in mm DM - Outer service pipe diameter in mm ААAА - Item 0511 - For Series 1 with HDPE jacket pipe 0512 - For Series 2 with HDPE jacket pipe 0513 - For Series 3 with HDPE jacket pipe 0521 - For Series 1 with spiral folded jacket pipe 0522 - For Series 2 with spiral folded jacket pipe 0523 - For Series 3 with spiral folded jacket pipe 0531 - For steam Series 1 with HDPE jacket pipe 0532 - For steam Series 2 with HDPE jacket pipe 0533 - For steam Series 3 with HDPE jacket pipe 0541 - For steam Series 1 with spiral folded jacket pipe 0542 - For steam Series 2 with spiral folded jacket pipe 0543 - For steam Series 2 with spiral folded jacket pipe Remarks: -The service pipe can be produced from carbonic or stainless steel, copper, polyethylene or another material, according to client's order. - The cover pipe can be produced from polyethylene or galvanized sheet iron respectively for underground and above-ground installation. - When the working fluid is steam, the heat insulation is increased with an additional heat-resistant layer, determined according to steam temperature. - Dimensions may vary according to client's request. - Valve dimensions: DN25, DN40 and DN50 Н 1200 4000 Plovdiv, 5 Dyakon Ilarion str tel: (032) 635 542, fax: (032) 268 547 e-mail: [email protected]; www.installpipe.com 11 PRE-INSULATED STOP VALVES SERIES 1, 2 AND 3 Length L = 1.5 m PRODUCER INSTALL ENGINEERING SV LTD NOMINAL DIAMETER DN mm SERVICE PIPE DM mm 25 32 40 50 65 80 100 125 150 200 250 300 ф33.7x2.6 ф42.4x2.6 ф48.3x2.6 ф60.3x2.9 ф76.1x2.9 ф88.9x3.2 ф114.3x3.6 ф139.7x3.6 ф168.3x4.0 ф219.1x4.5 ф273.0x5.0 ф323.9x5.6 DIAMETER JACKET PIPE DP mm Series 1 Series 2 Series 3 90 110 125 110 125 140 110 125 140 125 140 160 140 160 180 160 180 200 200 225 250 225 250 280 250 280 315 315 355 400 400 450 500 450 500 560 HEIGHT Н mm WIDTH B mm 480 485 495 500 505 515 525 545 565 585 625 665 110 110 110 110 110 110 125 125 125 160 160 160 HOW TO ORDER ААAА-DM DM - Outer service pipe diameter in mm ААAА - Item 0561 - For Series 1 with HDPE jacket pipe 0562 - For Series 2 with HDPE jacket pipe 0563 - For Series 3 with HDPE jacket pipe Remarks: B - The service pipe is produced from carbonic steel P235GH/ W.nr. 1.0345 (~St. 37.0). - Shaft - stainless steel AISI 316L. - Ball - stainless steel AISI 304. - Ring - PTFE reinforced carbon. - Sealing - PTFE reinforced carbon. - The cover pipe is produced from polyethylene for underground installation. - Dimensions may vary according to client's request. Н 1500 4000 Plovdiv, 5 Dyakon Ilarion str tel: (032) 635 542, fax: (032) 268 547 e-mail: [email protected]; www.installpipe.com 12 PRE-INSULATED ANCHOR POINTS SERIES 1, 2 AND 3 Length L = 2.0 m PRODUCER INSTALL ENGINEERING SV LTD NOMINAL DIAMETER DN mm SERVICE PIPE DM mm 25 32 40 50 65 80 100 125 150 200 250 300 400 ф33.7x2.3 ф42.4x2.6 ф48.3x2.6 ф60.3x2.9 ф76.1x2.9 ф88.9x3.2 ф114.3x3.6 ф139.7x3.6 ф168.3x4.0 ф219.1x4.5 ф273.0x5.0 ф323.9x5.6 ф406.4x6.3 DIAMETER JACKET PIPE DП mm mm mm Series 1 Series 2 Series 3 90 110 125 110 125 140 110 125 140 125 140 160 140 160 180 160 180 200 200 225 250 225 250 280 250 280 315 315 355 400 400 450 500 450 500 560 560 630 710 HEIGHT H mm WIDTH t mm STRESSED AREA cm2 200 220 220 240 280 300 350 400 450 550 650 700 850 25 25 25 25 25 30 30 30 30 35 40 40 40 191 243 243 289 452 392 565 765 875 1385 1730 1885 2560 HOW TO ORDER ААAА-DM DM - Outer service pipe diameter in mm ААAА - Item 0571 - For Series 1 with HDPE jacket pipe 0572 - For Series 2 with HDPE jacket pipe 0573 - For Series 3 with HDPE jacket pipe Remarks: - The service pipe can be produced from carbonic or stainless steel, copper, polyethylene or another material, according to client's order. - The cover pipe can be produced from polyethylene or galvanized sheet iron respectively for underground and above-ground installation. - When the working fluid is steam, the heat insulation is increased with an additional heat-resistant layer, determined according to steam temperature. - Dimensions may vary according to client's request. t Н 2000 4000 Plovdiv, 5 Dyakon Ilarion str tel: (032) 635 542, fax: (032) 268 547 e-mail: [email protected]; www.installpipe.com 13 PRE-INSULATED DOUBLE PIPES Length L = 12 m PRODUCER INSTALL ENGINEERING SV LTD DIAMETER NOMINAL DIAMETER 2 х DN mm 25 32 40 50 65 80 100 125 150 JACKET PIPE PIPE Dp mm 140 160 160 200 225 250 315 400 450 STEEL PIPE DM mm ф33.7x2.3 ф42.4x2.6 ф48.3x2.6 ф60.3x2.9 ф76.1x2.9 ф88.9x3.2 ф114.3x3.6 ф139.7x3.6 ф168.3x4.0 WEIGHT DISTANCE C kg/m 7.1 9.1 9.6 13.1 16.5 20.7 30.7 41.5 51.0 mm 19 19 19 20 20 25 25 30 40 HOW TO ORDER АААA-DМ DМ - Outer service pipe diameter in mm АААA - Item 0014 - For HDPE jacket pipe 0015 - For spiral folded jacket pipe Remarks: -The service pipe can be produced from carbonic or stainless steel, copper, polyethylene or another material, according to client's order. - The cover pipe can be produced from polyethylene or galvanized sheet iron respectively for underground and aboveground installation. - Dimensions may vary according to client's request. 12 m Dp DM С DM 4000 Plovdiv, 5 Dyakon Ilarion str tel: (032) 635 542, fax: (032) 268 547 e-mail: [email protected]; www.installpipe.com 14 PRE-INSULATED CURVED DOUBLE PIPES Length L = 12 m Maximum bending angle Y = 35o PRODUCER INSTALL ENGINEERING SV LTD DIAMETER WEIGHT NOMINAL DIAMETER 2 х DN STEEL PIPE JACKET PIPE PIPE mm 25 32 40 50 65 80 100 125 150 mm ф33.7x2.3 ф42.4x2.6 ф48.3x2.6 ф60.3x2.9 ф76.1x2.9 ф88.9x3.2 ф114.3x3.6 ф139.7x3.6 ф168.3x4.0 mm 140 160 160 200 225 250 315 400 450 kg/m 7.1 9.1 9.6 13.1 16.5 20.7 30.7 41.5 51.0 HOW TO ORDER АААA-DМ/Y Y - Bending angle in degrees DМ - Outer service pipe diameter in mm АААA - Itam 0016 - For HDPE jacket pipe 0017 - For spiral folded jacket pipe Remarks: - The service pipe can be produced from carbonic or stainless steel, copper, polyethylene or another material, according to client's order. - The cover pipe can be produced from polyethylene or galvanized sheet iron respectively for underground and aboveground installation. - Dimensions may vary according to client's request. Y 4000 Plovdiv, 5 Dyakon Ilarion str tel: (032) 635 542, fax: (032) 268 547 e-mail: [email protected]; www.installpipe.com 15 PRE-INSULATED BENDS DOUBLE PIPE Bending angle Y=90, 105, 120, 135, 150 and 165 degrees and upon request PRODUCER INSTALL ENGINEERING SV LTD NOMINAL DIAMETER 2 х DN STEEL PIPE mm 25 32 40 50 65 80 100 125 150 mm ф33.7x2.3 ф42.4x2.6 ф48.3x2.6 ф60.3x2.9 ф76.1x2.9 ф88.9x3.2 ф114.3x3.6 ф139.7x3.6 ф168.3x4.0 DIAMETER JACKET PIPE PIPE mm 140 160 160 200 225 250 315 400 450 LENGTH L mm 1000 1000 1000 1000 1000 1000 1000 1000 1000 HOW TO ORDER ААAА-DМ/Y Y - Bending angle in degrees DМ - Outer service pipe diameter in mm АААA - Item 0114 - For HDPE jacket pipe 0115 - For spiral folded jacket pipe Remarks: - The service pipe can be produced from carbonic or stainless steel, copper, polyethylene or another material, according to client's order. - The cover pipe can be produced from polyethylene or galvanized sheet iron respectively for underground and above-ground installation. - Dimensions may vary according to client's request. L Y L 4000 Plovdiv, 5 Dyakon Ilarion str tel: (032) 635 542, fax: (032) 268 547 e-mail: [email protected]; www.installpipe.com 16 PRE-INSULATED T-PIECES DOUBLE PIPE Deviation angle 90 degrees PRODUCER INSTALL ENGINEERING SV LTD NOMINAL DIAMETER MAIN PIPE DNM BRANCH PIPE DNO mm mm 25-100 25-100 125-150 125-150 LENGTH L1 mm 1200 1500 L2 mm 700 700 HOW TO ORDER ААAА-DNM/DNO DNО - Branch service pipe nominal diameter in mm DNM - Main service pipe nominal diameter in mm АААA - Item 0314 - For HDPE jacket pipe 0315 - For spiral folded jacket pipe Remarks: L2 L1 - The service pipe can be produced from carbonic or stainless steel, copper, polyethylene or another material, according to client's order. - The cover pipe can be produced from polyethylene or galvanized sheet iron respectively for underground and above-ground installation. - Dimensions may vary according to client's request. - The branch pipe diameter cannot exceed the diameter of the service pipe. 4000 Plovdiv, 5 Dyakon Ilarion str tel: (032) 635 542, fax: (032) 268 547 e-mail: [email protected]; www.installpipe.com 17 TRANSITION UNITS SINGLE/DOUBLE PIPE PRODUCER INSTALL ENGINEERING SV LTD DIAMETER NOMINAL DIAMETER 2 х DN mm 25 32 40 50 65 80 100 125 150 SERVICE PIPE DM mm ф33.7x2.3 ф42.4x2.6 ф48.3x2.6 ф60.3x2.9 ф76.1x2.9 ф88.9x3.2 ф114.3x3.6 ф139.7x3.6 ф168.3x4.0 JACKET PIPE DE/Dp mm 90/140 110/160 110/160 125/200 140/225 160/250 200/315 200/400 225/450 LENGTH L DISTANCE C mm 1600 1600 1600 1600 1600 1800 1800 2000 2100 mm 310 330 330 340 360 380 475 500 530 HOW TO ORDER АААA-DМ DМ - Outer service pipe diameter in mm ААAА - Item 0580 - For HDPE jacket pipe 0581 - For spiral folded jacket pipe Remarks: - The service pipe can be produced from carbonic or stainless steel, copper, polyethylene or another material, according to client's order. - The cover pipe can be produced from polyethylene or galvanized sheet iron respectively for underground and above-ground installation. - Dimensions may vary according to client's request. L Dp С DЕ 4000 Plovdiv, 5 Dyakon Ilarion str tel: (032) 635 542, fax: (032) 268 547 e-mail: [email protected]; www.installpipe.com 18 PRE-INSULATED AIR RELEASE/DRAINAGE UNITS DOUBLE PIPE Length L = 1.2 m PRODUCER NOMINAL DIAMETER 2 x DN mm 25 32 40 50 65 80 100 125 150 INSTALL ENGINEERING SV LTD DIAMETER SERVICE PIPE mm ф33.7x2.3 ф42.4x2.6 ф48.3x2.6 ф60.3x2.9 ф76.1x2.9 ф88.9x3.2 ф114.3x3.6 ф139.7x3.6 ф168.3x4.0 JACKET PIPE mm 140 160 160 200 225 250 315 400 450 HEIGHT Н mm 437 445 451 463 479 495 520 548 581 HOW TO ORDER АААA-DM/DNK DNK - Nominal valve diameter in mm DM - Outer service pipe diameter in mm АААA - Item 0514 - For HDPE jacket pipe 0515 - For spiral folded jacket pipe Remarks: - The service pipe can be produced from carbonic or stainless steel, copper, polyethylene or another material, according to client's order. - The cover pipe can be produced from polyethylene or galvanized sheet iron respectively for underground and above-ground installation. - Dimensions may vary according to client's request. - Valve dimensions: DN25, DN40 and DN50 Н 1200 4000 Plovdiv, 5 Dyakon Ilarion str tel: (032) 635 542, fax: (032) 268 547 e-mail: [email protected]; www.installpipe.com 19 PRE-INSULATED VALVES DOUBLE PIPE Distance between valves 200 mm PRODUCER INSTALL ENGINEERING SV LTD NOMINAL DIAMETER 2 х DN mm 25 32 40 50 65 80 100 125 150 SERVICE PIPE DM mm ф33.7x2.3 ф42.4x2.6 ф48.3x2.6 ф60.3x2.9 ф76.1x2.9 ф88.9x3.2 ф114.3x3.6 ф139.7x3.6 ф168.3x4.0 DIAMETER JACKET PIPE DP mm 140 160 160 200 225 250 315 400 450 HEIGHT Н mm 409 422 435 451 463 483 519 540 578 LENGTH L mm 1500 1500 1500 1500 1500 1500 1500 1500 1500 HOW TO ORDER АААA-DM DM - Outer service pipe diameter in mm АААA - Item 0564 - For HDPE jacket pipe 0565 - For spiral folderd jacket pipe Remarks: - The service pipe can be produced from carbonic or stainless steel, copper, polyethylene or another material, according to client's order. - The cover pipe can be produced from polyethylene or galvanized sheet iron respectively for underground and above-ground installation. - Dimensions may vary according to client's request. 200 Н L 4000 Plovdiv, 5 Dyakon Ilarion str tel: (032) 635 542, fax: (032) 268 547 e-mail: [email protected]; www.installpipe.com 20 PRE-INSULATED ANCHOR POINTS DOUBLE PIPE Length L = 2.0 m PRODUCER NOMINAL DIAMETER DN mm 25 32 40 50 65 80 100 125 150 INSTALL ENGINEERING SV LTD SERVICE PIPE DM mm ф33.7x2.3 ф42.4x2.6 ф48.3x2.6 ф60.3x2.9 ф76.1x2.9 ф88.9x3.2 ф114.3x3.6 ф139.7x3.6 ф168.3x4.0 DIAMETER JACKET PIPE DP mm 140 160 160 200 225 250 315 400 450 HEIGHT H mm 250 300 300 300 350 400 450 550 650 WIDTH t mm 20 20 20 20 30 30 30 35 40 STRESSED AREA cm2 337 505 505 390 565 765 810 1120 1720 HOW TO ORDER ААAА-DM DM - Outer service pipe diameter in mm АAАА - Item 0574 - For HDPE jacket pipe 0575 - For spiral folded jacket pipe Remarks: - The service pipe can be produced from carbonic or stainless steel, copper, polyethylene or another material, according to client's order. - The cover pipe can be produced from polyethylene or galvanized sheet iron respectively for underground and above-ground installation. - Dimensions may vary according to client's request. t Н 2000 4000 Plovdiv, 5 Dyakon Ilarion str tel: (032) 635 542, fax: (032) 268 547 e-mail: [email protected]; www.installpipe.com 21 AXIAL COATED COMPENSATORS Nominal pressure PN = 16 bar PRODUCER T-COMP Denmark NOMINAL DIAMETER DN mm 32 40 50 65 80 100 125 150 175 200 250 300 350 400 450 500 OUTER DIAMETER Du mm 73.0 73.0 86.0 102.0 123.0 139.7 168.3 193.7 219.1 268.0 323.9 355.6 406.0 460.0 510.0 560.0 MAXIMUM AXIAL FORCE ELONGATION ∆L mm N/mm 100 63 100 57 100 71 100 77 100 124 125 105 125 108 125 120 125 126 125 152 125 203 125 241 125 265 125 404 125 434 125 482 LENGTH L mm 605 605 605 640 620 795 765 755 750 745 815 875 790 790 790 790 HOW TO ORDER 0600-DN/∆L ∆L - Maximum elongation in mm DN - Nominal diameter in mm Du L 4000 Plovdiv, 5 Dyakon Ilarion str tel: (032) 635 542, fax: (032) 268 547 e-mail: [email protected]; www.installpipe.com 22 AXIAL COATED COMPENSATORS Nominal pressures PN = 16 и 25 bar PRODUCER T-COMP Denmark NOMINAL DIAMETER DN mm 32 40 50 65 80 100 125 150 175 200 250 300 350 400 450 500 600 OUTER DIAMETER Du mm 16 bar 73.0 73.0 86.0 102.0 123.0 139.7 168.3 193.7 219.1 268.0 323.9 355.6 406.0 460.0 510.0 560.0 675.0 25 bar 132 160 185 220 247 272 326 385 417 468 519 572 683 MAXIMUM ELONGATION ∆L mm 16 bar 25 bar 200 200 200 200 200 180 250 180 250 180 250 180 250 180 250 180 250 180 250 180 250 180 250 180 250 180 250 180 250 180 AXIAL FORCE N/mm 16 bar 25 bar 32 29 36 38.5 62 136 53 119 54 133 60 146 63 180 76 203 102 201 121 312 133 313 202 306 217 344 241 288 289 431 LENGTH L mm 16 bar 1100 1100 1100 1350 1150 1450 1400 1400 1400 1350 1470 1600 1450 1450 1450 1450 1500 25 bar 1100 1100 1100 1100 1150 1200 1200 1200 1200 1200 1200 1200 1300 HOW TO ORDER 0604-DN-∆L-PN PN - Nominal pressure in bar ∆L - Maximum elongation in mm DN - Nominal diameter in mm Du L 4000 Plovdiv, 5 Dyakon Ilarion str tel: (032) 635 542, fax: (032) 268 547 e-mail: [email protected]; www.installpipe.com 23 ONE-TIME AXIAL COATED COMPENSATORS Nominal pressures PN = 16 и 25 bar PRODUCER T-COMP Denmark NOMINAL DIAMETER DN mm 25 32 40 50 65 80 100 125 150 175 200 250 300 350 400 450 500 600 OUTER DIAMETER Du mm 56.0 73.0 73.0 86.0 106.0 122.0 139.7 168.3 193.7 219.1 268.0 323.9 355.6 406.4 457.2 508.0 560.0 675.0 MAXIMUM ELONGATION ∆L mm 50 50 50 50 70 70 80 80 100 100 120 120 140 140 140 150 150 150 AXIAL FORCE LENGTH L mm 275 275 275 275 335 345 390 400 475 475 515 515 660 650 650 660 660 690 N/mm 176 204 177 224 219 180 212 226 261 648 361 362 353 617 505 528 537 864 HOW TO ORDER 0601-DN-∆L-PN PN - Nominal pressure in bar ∆L - Maximum elongation in mm DN - Nominal diameter in mm Du L 4000 Plovdiv, 5 Dyakon Ilarion str tel: (032) 635 542, fax: (032) 268 547 e-mail: [email protected]; www.installpipe.com 24 AXIAL COMPENSATORS Nominal pressures PN = 10, 16 и 25 bar PRODUCER T-COMP Denmark NOMINAL DIAMETER DN mm 25 32 40 50 65 80 100 125 150 200 250 300 350 400 450 500 600 AXIAL FORCE MAXIMUM ELONGATION ∆L mm N/mm 10 bar 16 bar 25 bar 10 bar 16 bar 25 bar 10 10 10 127 127 236 10 10 10 146 146 236 20 20 15 204 204 252 25 20 20 172 208 381 30 30 15 130 233 310 35 35 20 184 203 320 35 35 25 94 234 328 35 35 25 233 233 442 40 40 30 151 247 441 40 40 30 173 259 574 55 40 30 174 323 631 55 40 30 310 383 748 55 45 35 393 445 685 55 45 30 366 715 1394 55 45 30 418 817 1568 55 45 30 465 908 1618 55 45 30 558 1089 2427 LENGTH 10 bar 175 180 235 245 220 240 200 245 220 235 260 265 285 305 265 265 265 L mm 16 bar 175 180 235 225 235 230 245 245 230 245 245 245 270 310 275 275 275 25 bar 175 175 215 240 205 220 210 230 230 230 250 250 255 260 270 240 250 HOW TO ORDER 0602-DN-∆L-PN PN - Nominal pressure in bar ∆L - Maximum elongation in mm DN - Nominal diameter in mm L 4000 Plovdiv, 5 Dyakon Ilarion str tel: (032) 635 542, fax: (032) 268 547 e-mail: [email protected]; www.installpipe.com 25 AXIAL COMPENSATORS WITH FLANGES Nominal pressures PN = 10, 16 и 25 bar NOMINAL DIAMETER DN mm 25 32 40 50 65 80 100 125 150 200 250 300 350 400 450 500 600 AXIAL FORCE MAXIMUM ELONGATION ∆L mm N/mm 10 bar 16 bar 25 bar 10 bar 16 bar 25 bar 10 10 10 127 127 236 10 10 10 146 146 236 20 20 15 204 204 252 25 20 20 172 208 381 30 30 15 130 233 310 35 35 20 184 203 320 35 35 25 94 234 328 35 35 25 233 233 442 40 40 30 151 247 441 40 40 30 173 259 574 55 40 30 174 323 631 55 40 30 310 383 748 55 45 35 393 445 685 55 45 30 366 715 1394 55 45 30 418 817 1568 55 45 30 465 908 1618 55 45 30 558 1089 2427 LENGTH 10 bar 90 95 145 160 140 160 125 170 145 165 195 200 225 250 225 225 240 L mm 16 bar 130 140 200 195 205 210 230 240 220 245 265 280 315 360 325 335 345 25 bar 135 139 185 215 190 215 220 246 260 270 305 310 335 360 370 370 380 HOW TO ORDER 0603-DN-∆L-PN PN - Nominal pressure in bar ∆L - Maximum elongation in mm DN - Nominal diameter in mm L 4000 Plovdiv, 5 Dyakon Ilarion str tel: (032) 635 542, fax: (032) 268 547 e-mail: [email protected]; www.installpipe.com 26 SHRINKABLE CASINGS Length 500 - 700 mm PRODUCER HDPE pipe diameter D mm 63 75 90 110 125 140 160 180 200 225 250 280 315 355 400 450 500 520 560 630 670 710 800 900 1000 SALLING PLAST AS Denmark Casing inner diameter DВ mm 77 89 103 125 140 156 177 197 218 244 269 300 336 377 425 474 530 556 590 660 713 749 838 949 1060 Length L Casing wall thickness w. mastix mm 500 - 700 500 - 700 500 - 700 500 - 700 500 - 700 500 - 700 500 - 700 500 - 700 500 - 700 500 - 700 500 - 700 500 - 700 500 - 700 500 - 700 500 - 700 500 - 700 500 - 700 500 - 700 500 - 700 500 - 700 500 - 700 500 - 700 500 - 700 500 - 700 500 - 700 mm 3,0 3,0 3,0 3,0 3,0 3,0 3,0 3,5 3,5 3,5 4,0 4,0 4,5 5,0 5,5 6,5 7,5 7,8 8,8 9,8 12,3 11,1 12,5 14,0 15,6 Welded mm 500 - 700 500 - 700 500 - 700 500 - 700 500 - 700 500 - 700 500 - 700 500 - 700 500 - 700 500 - 700 500 - 700 500 - 700 500 - 700 500 - 700 500 - 700 500 - 700 500 - 700 500 - 700 500 - 700 500 - 700 500 - 700 500 - 700 500 - 700 500 - 700 500 - 700 HOW TO ORDER АААА-D/L L - Casing length D - Outer diameter of HDPE pipe in mm АААА - Item 0701 - Shrinkable casing w. mastix 0723 - Welded casing DВ Remarks: Their purpose is to link two preinsulated welded pipe ends, ensuring the tightness of connections. Installation is through heating, which causes the casings to shrink. The space between the casing and the service pipe is filled with polyurethane foam. L 4000 Plovdiv, 5 Dyakon Ilarion str tel: (032) 635 542, fax: (032) 268 547 e-mail: [email protected]; www.installpipe.com 27 SHRINKABLE OPEN CASINGS Length - L = 450, 650, 760 and 900 mm PRODUCER SALLING PLAST AS Denmark HDPE pipe diameter D mm 90 110 125 140 160 180 200 225 250 280 315 355 400 450 500 560 630 HOW TO ORDER 0703-D/L L - Casing length in mm D - Outside diameter of HDPE pipe in mm DВ Remarks: Their purpose is to link two preinsulated welded pipe ends, ensuring the tightness of connections. The open end of the casings has self-adhesive coating. Installation is through heating, which causes the casings to shrink. The space between the casing and the service pipe is filled with polyurethane foam. L 4000 Plovdiv, 5 Dyakon Ilarion str tel: (032) 635 542, fax: (032) 268 547 e-mail: [email protected]; www.installpipe.com 28 SHRINKABLE BAND Width - W = 150, 225, 650, 760 and 900 mm Length L = 15 и 30 m PRODUCER SALLING PLAST AS Denmark HOW TO ORDER 0713-W/L L - Band length in m W - Band width in mm W Remarks: Their purpose is to link the ends of the casing with the HDPE pipe. Installation is through heating, which causes the casings to shrink. L 4000 Plovdiv, 5 Dyakon Ilarion str tel: (032) 635 542, fax: (032) 268 547 e-mail: [email protected]; www.installpipe.com 29 ORDINARY CASINGS Length - 500, 600, 700 mm PRODUCER SALLING PLAST AS Denmark HDPE pipe diameter D mm 63 75 90 110 125 140 160 180 200 225 250 280 315 355 400 450 500 560 630 710 800 900 1000 Casing inner diameter DВ mm 69 84 96 116 132 149 170 189 209 237 263 290 329 370 413 464 517 578 648 733 827 929 1028 Casing wall thickness mm 3,0 3,0 3,0 3,0 3,0 3,0 3,5 3,5 3,5 4,0 4,0 4,5 5,0 5,5 6,5 7,5 8,0 8,5 9,0 11,1 12,5 14,0 15,6 HOW TO ORDER 0704-D/L L - Casing length in mm D - HDPE pipe outside diameter in mm DВ Remarks: Their purpose is to link two preinsulated welded pipe ends, ensuring the tightness of connections. The space between the casing and the service pipe is filled with polyurethane foam. L 4000 Plovdiv, 5 Dyakon Ilarion str tel: (032) 635 542, fax: (032) 268 547 e-mail: [email protected]; www.installpipe.com 30 SHRINKABLE REDUCTION CASINGS Length L = 700 mm, 900 mm PRODUCER SALLING PLAST AS Denmark Small HDPE pipe diameter DB1 Large HDPE pipe diameter DB2 Inner diameter casing DB1/DB2 mm 63 mm 75 90 110 125 140 90 110 125 140 160 110 125 140 160 180 125 140 160 180 200 140 160 180 200 225 160 180 200 225 250 180 200 225 250 280 mm 77/89 77/103 77/125 77/140 77/156 89/103 89/125 89/140 89/156 89/177 103/125 103/140 103/156 103/177 103/197 125/140 125/156 125/177 125/197 125/218 140/156 140/177 140/197 140/218 140/244 156/177 156/197 156/218 156/244 156/269 177/197 177/218 177/244 177/269 177/300 75 90 110 125 140 160 HOW TO ORDER 0705-DB2/DB1/L Small HDPE pipe Large HDPE pipe diameter DB1 diameter DB2 mm 180 mm 200 225 250 280 315 225 250 280 315 355 250 280 315 280 315 355 400 315 355 400 355 400 450 400 450 450 500 500 560 560 630 710 800 900 1000 200 225 250 280 315 355 400 450 500 560 630 710 800 900 Inner diameter casing DB1/DB2 mm 197/218 197/244 197/269 197/300 197/336 218/244 218/269 218/300 218/336 218/377 244/269 244/300 244/336 269/300 269/336 269/377 269/425 300/336 300/377 300/425 336/377 336/425 336/474 377/425 377/474 425/474 425/530 476/530 474/590 530/590 590/660 660/749 749/838 838/949 949/1060 Casing length in mm DB1 - Small HDPE pipe diameter in mm DB2 - Large HDPE pipe diameter in mm DB2 DB1 Remarks: Their purpose is to link two preinsulated welded pipe ends with different sizes, ensuring the tightness of connections.Installation is through heating, which causes the casings to shrink. The space between the casing and the service pipe is filled with polyurethane foam. L 4000 Plovdiv, 5 Dyakon Ilarion str tel: (032) 635 542, fax: (032) 268 547 e-mail: [email protected]; www.installpipe.com 31 END CASINGS Length L 500 mm PRODUCER SALLING PLAST AS Denmark HDPE pipe diameter D mm 63 75 90 110 125 140 160 180 200 225 250 280 315 355 400 450 500 560 630 710 800 900 1000 Casing inner diameter DВ mm 69 84 96 116 132 149 170 189 209 237 263 290 329 370 413 464 517 578 648 733 827 929 1028 Casing wall thickness mm 3,0 3,0 3,0 3,0 3,0 3,0 3,5 3,5 3,5 4,0 4,0 4,5 5,0 5,5 6,5 7,5 8,0 8,5 9,0 11,1 12,5 14,0 15,6 HOW TO ORDER 0706-D/500 D - Outer diameter of HDPE pipe in mm DВ Remarks: Their purpose is to fully close the end of a HDPE pipe, ensuring tightness of closing. Installation is through heating, which causes the casings to shrink. The space between the casing and the service pipe is filled with polyurethane foam. 500 4000 Plovdiv, 5 Dyakon Ilarion str tel: (032) 635 542, fax: (032) 268 547 e-mail: [email protected]; www.installpipe.com 32 END CAPS Lengths L = 500 and 700 mm PRODUCER SALLING PLAST AS Denmark HDPE pipe diameter Dp Service pipe diameter DМ Minimum service pipe diameter mm 110 125 140 mm 48 60 60 76 76 89 76 89 89 114 114 140 114 140 168 140 168 194 168 219 219 219 273 273 324 273 324 356 356 406 mm 48 55 60 60 65 65 70 70 85 85 100 100 110 110 110 125 125 125 140 140 150 160 160 190 190 210 210 210 220 220 160 180 200 225 250 280 315 355 400 450 500 520 Small HDPE pipe Large HDPE pipe Minimum service diameter DB1 diameter DB2 pipe diameter mm 560 630 670 710 780 800 900 1000 1100 1200 mm 324 356 406 457 356 406 457 508 406 457 508 406 457 508 558 559 610 457 508 559 510 508 559 610 711 610 711 813 813 914 914 1016 mm 210 210 210 210 245 245 245 245 250 250 250 265 265 265 265 290 290 300 300 300 300 335 335 335 335 375 375 375 405 405 440 440 HOW TO ORDER 0707-DП/DМ/L L - Cap length in mm DB1 - Small HDPE pipe diameter in mm DB2 - Large HDPE pipe diameter in mm Dp DМ Remarks: Their purpose is to fully close the end of a HDPE pipe to the service pipe surface, ensuring the tightness of the closing. Installation is through heating, which causes the casings to shrink. L 4000 Plovdiv, 5 Dyakon Ilarion str tel: (032) 635 542, fax: (032) 268 547 e-mail: [email protected]; www.installpipe.com 33 "О"- RINGS PRODUCER SALLING PLAST AS Denmark HDPE pipe diameter D 63 75 90 110 125 140 160 180 200 225 250 280 315 355 400 450 500 560 630 710 800 900 1000 1100 1200 HOW TO ORDER 0708-D D - Outside diameter of HDPE pipe in mm Remarks: Their purpose is to close the space between the HDPE pipe and walls, concrete channels, etc. in building constructions. D 4000 Plovdiv, 5 Dyakon Ilarion str tel: (032) 635 542, fax: (032) 268 547 e-mail: [email protected]; www.installpipe.com 3534
© Copyright 2024 Paperzz