Mess-, Regel- und Überwachungsgeräte für Haustechnik, Industrie und Umweltschutz Lindenstraße 20 74363 Güglingen Telefon +49 7135-102-0 Service +49 7135-102-211 Telefax +49 7135-102-147 [email protected] www.afriso.de Operating Instructions Alarm unit for oil and petrol separators WGA 01 WGA 01 Probe WGA-R6 Probe WGA-ES4 # 53410 # 53419 # 53418 Layer level alarm/overflow alarm Read instructions before using device! Observe all safety information! Keep instructions for future use! 09.2012 1 854.001.0397 0123 Contents 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 2 This instruction manual............................................................................................ 3 1.1 Precautions .................................................................................................. 3 1.2 Explanation of symbols and typeface .......................................................... 3 Safety....................................................................................................................... 4 2.1 Intended use................................................................................................. 4 2.2 Predictable incorrect application .................................................................. 4 2.3 Safe handling ............................................................................................... 4 2.4 Staff qualification .......................................................................................... 4 2.5 Modifications to the product ......................................................................... 4 2.6 Usage of spare parts and accessories ......................................................... 5 2.7 Liability information ...................................................................................... 5 Product description .................................................................................................. 5 3.1 Function........................................................................................................ 6 3.2 Front buttons and LED indicators................................................................. 6 Specifications .......................................................................................................... 6 Transportation and storage ..................................................................................... 8 Mounting and commissioning .................................................................................. 8 6.1 Electrical connection .................................................................................... 9 6.2 Commission the device .............................................................................. 10 6.3 Test ............................................................................................................ 11 Operation ............................................................................................................... 11 Maintenance .......................................................................................................... 12 Shutting down and disposal .................................................................................. 12 Spare parts and accessories ................................................................................. 13 Warranty ................................................................................................................ 13 Copyright ............................................................................................................... 13 Customer satisfaction ............................................................................................ 13 Addresses .............................................................................................................. 13 Appendix ................................................................................................................ 14 15.1 Approval documents evaluation unit .......................................................... 14 15.2 Approval documents WGA-ES4 capacitance probe .................................. 15 15.3 Approval documents WGA-R6 PTC thermistor probe ............................... 15 15.4 Declaration of conformity ........................................................................... 16 WGA 01 This instruction manual 1 This instruction manual This instruction manual is part of the product. Read this manual before using the product. Keep this manual during the entire service life of the product and always have it readily available for reference. Always hand this manual over to future owners or users of the product. 1.1 Precautions WARNING TERM Type and source of the danger is shown here. Precautions to take in order to avoid the danger are shown here. There are three different levels of warnings: 1.2 WGA 01 Warning term Meaning DANGER Immediately imminent danger! Failure to observe the information will result in death or serious injuries. WARNING Possibly imminent danger! Failure to observe the information may result in death or serious injuries. CAUTION Dangerous situation! Failure to observe the information may result in minor or serious injuries as well as damage to property. Explanation of symbols and typeface Symbol Meaning Prerequisite for an activity Activity consisting of a single step 1. Activity consisting of several steps Result of an activity • Bulleted list Text Indication on a display Highlighting Highlighting 3 Safety 2 2.1 Safety Intended use The WGA 01 alarm unit consists of a evaluation unit, a capacitance probe (WGA-ES4) and optional a PTC thermistor probe (WGA-R6). With the WGA-ES4 capacitance probe the WGA 01 alarm unit is exclusively suitable for detecting the layer level in an oil/grease separator. With the additional WGA-R6 PTC thermistor probe the WGA 01 alarm unit is exclusively suitable for detecting the maximum level (overflow alarm). Any use other than the use explicitly permitted in this instruction manual is not permitted. 2.2 Predictable incorrect application The WGA 01 alarm unit must never be used in the following cases: • Using the evaluation unit in hazardous areas (ex) If the device is operated in hazardous areas, sparks may cause deflagrations, fires or explosions 2.3 Safe handling The WGA 01 alarm unit represents state-of-the-art technology and is made according to the pertinent safety regulations. Each device is subjected to a function and safety test prior to shipping. Operate the WGA 01 alarm unit only when it is in perfect condition. Always observe the operating instructions, all pertinent local and national directives and guidelines as well as the applicable safety regulations and directives concerning the prevention of accidents. 2.4 Staff qualification The product may only be mounted, commissioned, operated, maintained, shut down and disposed of by qualified, specially trained staff. Electrical work may only be performed by trained electricians qualified in accordance with the local and national directives. 2.5 Modifications to the product Changes or modifications made to the product by unauthorised persons may lead to malfunctions and are prohibited for safety reasons. 4 WGA 01 Product description 2.6 Usage of spare parts and accessories Usage of unsuitable spare parts and accessories may cause damage to the product. Use only genuine spare parts and accessories of the manufacturer (refer to chapter 10, page 13). 2.7 Liability information The manufacturer shall not be liable for direct or consequential damage resulting from failure to observe the technical instructions, guidelines and recommendations. The manufacturer and the sales company shall not be liable for costs or damages incurred by the user or by third parties in the usage or application of this device, in particular in case of improper use of the device, misuse or malfunction of the connection, malfunction of the device or of connected devices. The manufacturer or the sales company shall not be liable for damages resulting from any use other than the use explicitly permitted in this instruction manual. The manufacturer shall not be liable for misprints. 3 Product description Bild 1: Evaluation unit Bild 2: WGA-ES4 capacitance probe Bild 3: WGA-R6 PTC thermistor probe The evaluation unit and the WGA-ES4 capacitance probe are included in delivery. Optional the WGA-RG PTC thermistor probe is additionally included in delivery. WGA 01 5 Specifications 3.1 Function The sensing probe circuits are intrinsically safe. The evaluation unit has a selectable jumper link on the printed circuit board (only accessible with the front cover removed) which provides selection for the number of sensing probes.It has two positions: • 1 = WGA-ES4 capacitance probe only • 2 = WGA-ES4 capacitance probe and WGA-R6 PTC thermistor probe On start-up the control evaluation unit automatically checks to determine if one or two sensors are connected. With the jumper link in position 1 the evaluation unit will not give a sensor failure alarm when the WGA-R6 PTC thermistor probe is omitted. 3.2 Front buttons and LED indicators 1 LED for layer level alarm and failure alarm 2 LED for overflow alarm and failure alarm 3 Test button 4 Reset button Bild 4: Front buttons and LED indicators of the evaluation unit 4 Specifications Tabelle 1: Specifications evaluation unit Parameter Value General specifications Intrinsically safe II (1) G [EEx ia] II B Sensor output galvanically isolated from earth. Intrinsically parameters C0 = 0.60 µF; L0 = 2.0 mH Sensor output I0 = 170 mA; U0 = 24.9 V; P0 = 1.1 W Relay outputs, contact data Um 250 V, Im 5 A, max. 100 VA (AC) Um 24 V, Im 1.5 A, 20 W (DC) Protection 6 IP 65 WGA 01 Specifications Parameter Value Operating temperature range Ambient 0 to +40 °C Supply Power supply 230 V, 50 Hz Tabelle 2: Specifications WGA-ES4 capacitance probe Parameter Value General specifications Intrinsically safe II 1 G EEx ia II A T4 Sensor must be connected to barrier isolated from earth. Electrical parameters 500 nF; Li = 10 µH; Ii = 170 mA; Ui = 25,0 V; Pi = 1,1 W Operating temperature range Ambient -20 to +40 °C Tabelle 3: Specifications WGA-R6 PTC thermistor probe Parameter Value General specifications Intrinsically safe II 1 G EEx ia II A T3 Sensor must be connected to barrier isolated from earth. Electrical parameters 1 nF; Li = 10 µH; Ii = 200 mA; Ui = 30,0 V; Pi = 1,0 W Operating temperature range Ambient WGA 01 -25 to +50 °C 7 Transportation and storage 5 Transportation and storage CAUTION Damage to the device due to improper transportation. CAUTION 6 Do not throw or drop the device. Damage to the device due to improper storage. Protect the device against shock when storing it. Store device in a clean and dry environment. Mounting and commissioning Evaluation unit All regulations and instructions for the installation and maintenance of EX certified equipment must be observed (EN 6007914, EN 60079-17 CENELEC). Use 4 screws to mount the evaluation unit directly on a wall. Probes Fix the ES4 capacitance probe at a height 150 mm below the constant water level in the separator. The WGA-ES4 capacitance probe must be immersed in water to prevent an alarm being initiated. The WGA-R6 PTC thermistor probe must be immersed in air to prevent an alarm being initiated. 1 Oil 2 Water 3 WGA-ES4 capacitance probe 4 WGA-R6 PTC thermistor probe Bild 5: Mounting the probes 8 If a 1" cable gland is used for the mounting in the tank make sure that the cable is securely tightened. WGA 01 Mounting and commissioning 6.1 Make sure that the sensor is easy to lift out of the tank in order to protect the probe when emptying the tank. The cable should be mechanically protected. If the device is used for oil surface and high level alarm functions, make sure the WGA-R6 PTC thermistor probe is mounted at the correct level in the separator tank. Electrical connection The cable should be mechanically protected. The intrinsically safe circuit is not allowed to be earthed. If the sensor cable needs to be extended, screened cable 2 should be used (2 x 1,5 mm , maximum length 200 m). Bild 6: Cable connections P1 WGA-ES4 capacitance probe 1 Brown P2 WGA-R6 PTC thermistor probe 2 Blue R1 Voltage-free relay contact for layer level alarm a 230 V supply R2 Voltage-free relay contact for overflow alarm R1 and R2 are shown in the de-energised state, in an alarm condition. 1. Connect the power supply to connector block K1. 2. Layer level alarm: Connect the WGA-ES4 capacitance probe to block P1. 3. Overflow alarm (optional): Additionally connect the WGA-R6 PTC thermistor probe to block P2. WGA 01 9 Mounting and commissioning 4. Select the right jumper position: 1 Position 1 (factory setting): Only layer level alarm 2 Position 2: layer level alarm and overflow alarm Bild 7: Jumper 6.2 Commission the device 1. 2. 3. 10 Make sure that the connections are made correctly in accordance with fig. 6, page 9. Incorrect polarity of the sensor cables will result in an alarm on the evaluation unit. Make sure that the correct cable type and size has been used. Make sure the jumper is in the correct position, refer to fig. 7, page 10. Make sure that the probes have been mounted at the correct hight. Make sure that the cable glands are properly tightened. Correctly connect the ribbon cable to the pin connector on the circuit board. Close the lid. Start the evaluation unit. WGA 01 Operation While starting the evaluation unit will perform a diagnostic check of the sensor inputs. In the event of an incorrect connection or sensor fault an alarm will be given within 30 seconds. 6.3 Test The evaluation unit has a built-in test function which is used to test the alarm functions, the relay outputs and the LED indicators. Press and hold the "Test" button for approximately 3 seconds. The test function starts and will go on as follows: For 5 seconds a layer level alarm is given. The red LED for layer level alarm is illuminated and relay R1 is de-energised. For 5 seconds an overflow alarm is given. The red LED will be illuminated and relay R2 is de-energised. For 5 seconds no alarms is given and relays R1 and R2 are energised. 7 The evaluation unit will revert to the normal operating condition. Operation WGA 01 will only give a layer level alarm if there is a definite oil or grease surface layer on the water in the separator chamber. Please be aware that certain solvents and chemicals can destroy or degrade the oil or surface layer which could make it impossible for the unit to provide a proper layer level alarm. Normal operation – no alarm No senor alarms given. • Green LEDs for "layer level alarm" and "overflow alarm" illuminate. • Relays R1 and R2 are energized. Overflow alarm • The red LED for „overflow alarm“ is illuminated. • The internal buzzer sounds. • R2 is de-energized. Layer level alarm • The red LED for „layer level alarm“ is illuminated. • The internal buzzer sounds. • R1 is de-energized. WGA 01 11 Maintenance Probe failure alarm – layer level • With a short circuit on the layer level alarm sensor input the red LED "layer level alarm" flashes quick (at a rate of 1 Hz), with an open circuit the red LED flashes slow (at a rate of 1/3 Hz). • The internal buzzer sounds. • R1 is de-energized. Probe failure alarm – overflow • With a short circuit on the overflow alarm sensor input the red LED "overflow alarm" flashes quick (at a rate of 1 Hz), with an open circuit the red LED flashes slow (at a rate of 1/3 Hz). • The internal buzzer sounds. • R2 is de-energized. Acknowledge alarms Press the reset button. The internal buzzer mutes. The buzzer will sound again after approximately 20 hours if the alarm condition has not been corrected. 8 Maintenance Repair and modification is not permitted on site. Send the unit to the manufacturer or supplier for attention. 9 Shutting down and disposal 1. 2. Switch off mains voltage. Dismount the device (see chapter 0, page 8, reverse sequence of steps). 3. To protect the environment, this device must not be disposed of together with the normal household waste. Dispose of the device according to the local conditions and directives. This device consists of materials that can be reused by recycling firms. The electronic inserts can be easily separated and the device consists of recyclable materials. If you do not have the opportunity to dispose of the used device in accordance with environmental regulations, please contact us for possibilities to dispose of it or to return it. 12 WGA 01 Spare parts and accessories 10 Spare parts and accessories Part Part No. Event reporting system Phone Alarm SD1 90003 Event reporting system GSM Alarm 90002 Event reporting system EMS 220 90220 Event reporting system EMS 442 90442 11 Warranty The warranty of the manufacturer for this product is 24 months after the date of purchase. This warranty shall be good in all countries in which this device is sold by the manufacturer or its authorised dealers. 12 Copyright The manufacturer retains the copyright to this manual. This manual may only be reprinted, translated, copied in part or in whole with the prior written consent of the manufacturer. We reserve the right to technical modifications with reference to the specifications and illustrations in this manual. 13 Customer satisfaction Customer satisfaction is our prime objective. Please get in touch with us if you have any questions, suggestions or problems concerning your product. 14 Addresses The addresses of our worldwide representations and offices can be found on the Internet at www.afriso.de. WGA 01 13 Appendix 15 Appendix 15.1 14 Approval documents evaluation unit WGA 01 Appendix 15.2 Approval documents WGA-ES4 capacitance probe 15.3 Approval documents WGA-R6 PTC thermistor probe WGA 01 15 Appendix 15.4 16 Declaration of conformity WGA 01
© Copyright 2026 Paperzz