131263_City-South_Manchester_v5__ 19/03/2012 12:00 Page 1 Transforming homes from G to A Low Carbon Housing Retrofit 1 An assessment of the archetype requirements and recommendations for improving the energy efficiency of dwellings in Greater Manchester Low Carbon Housing Retrofit Greater Manchester 131263_City-South_Manchester_v5__ 19/03/2012 12:00 Page 2 Foreword Over the past few years there has been a growing recognition of the magnitude of the challenge that the UK and the rest of the world is facing in terms of meeting carbon emissions reduction targets. Emissions related to domestic housing account for over Greater Manchester features many stakeholders fully 25% of our overall output and so housing has a critical committed to the housing retrofit agenda – this document role to play in contributing to the wider goals. will assist as initiatives such as Green Deal and the new As new technologies emerge for energy reduction and generation it is easy to forget about the requirements to properly insulate the fabric of existing buildings – this Energy Company Obligations are implemented and help GM along the way towards its ambitious 2050 emission reduction goals for housing. document looks at the nature of Greater Manchester’s housing stock and sets out approaches to move homes towards the upper end of the energy efficiency scale. Ashley Crumbley Acknowledgements Low Carbon Housing Retrofit 2 Tom Rock, (Chair) Alan Foster, Andy Kippax, Andy Morris, Charlie Baker, Gavin Summerson, Michael O’Doherty, Paul Maidment, Richard Hartless, Ross Hall, Shona Thomas, Stephen Passmore, Stephen Todd, Steve Parlby, Tim Barwood, Tony Baldwinson, William Swan, City South Manchester Housing Trust Homes and Communities Agency (HCA) Stockport Metropolitan Borough Council Bolton at Home Urbed Building Research Establishment Manchester City Council Northwards Housing Building Research Establishment Building Research Establishment Greater Manchester Low Carbon Housing Retrofit Programme Energy Saving Trust Salford University Irwell Valley Housing Association Greater Manchester Low Carbon Housing Retrofit Programme NW Centre for Construction Innovation Salford University Image courtesy of Manchester City Council 131263_City-South_Manchester_v5__ 19/03/2012 12:01 Page 3 Contents Executive Summary and Recommendations 2 Housing Retrofit potential in Greater Manchester • Property Archetypes • Identification of Property Types • Options for Improvement • Retrofit Potential • Measures Options – Basic Measures – Intermediate measures – Major Measures • Wall Types and Appropriate Treatment • Summary 3 Specific Considerations • Building Regulations and Planning • Flood Damage Risk • Fire Risk • Interstitial and Surface Condensation • Ventilation and Building Physics • Sustainability and the Home • Design Considerations • Technology Advancement • Summary 4 Conclusions 5 Recommendations Technical Appendices: A: Typical Ranges of Measures B: Wall U-Values and Improvements C: References and Sources D: Glossary of technical terms Low Carbon Housing Retrofit 1 Developing a Housing Retrofit Standard for Existing Stock • Background • The Challenge of the Task Group • Green Deal Guidance • Potential Financial Savings • Aims of the Report • Decision Making • Potential Economic and Social Benefits • Fuel Poverty • Energy Performance Certificate • Summary 3 131263_City-South_Manchester_v5__ 19/03/2012 12:01 Page 4 Executive Summary and Recommendations Introduction As we move closer to the Government’s launch of the Green Deal in autumn 2012, it is important for the Association of Greater Manchester Authorities (AGMA) to ensure they are in a position to deliver the best advice and maximise the benefits to its residents. Over the past 12 months Greater Manchester’s Low Carbon Economic Area (LCEA) Domestic Retrofit programmes have been focused on this agenda to ensure the region can maximise what the Green Deal has to offer to GM residents. Low Carbon Housing Retrofit 4 In order to achieve this key housing retrofit stakeholders, operating through AGMA’s Environment Commission, have started bringing together a set of independent recommendations and technical advice that is relevant to GM’s housing stock characteristics, which will help to underpin the specifying and planning of retrofit projects. In order to maximise the impact of Green Deal uptake and provide a route to meeting the local and national emissions reduction challenge for GM, this Greater Manchester Housing Retrofit Design Guidance has been developed. Aims of the report There are more that 1.1 million homes in Greater Manchester which contribute 36% of the CO2 emissions for the area1. This provides a significant challenge and opportunity to target domestic housing in order to meet the local and national emissions reduction targets. It is intended that this report will enable all users, from individual householders to large scale landlords and those involved in planning and installing retrofit measures, to understand the potential range of energy efficiency measures that may be fitted to their properties and the most efficient order in which to install them. In addition to applying the basic, intermediate and major measures, the users’ opportunity for saving money by reducing their ongoing energy usage is highlighted. These recommendations and packages of measures are linked to the Greater Manchester Climate Change Strategy2 emissions reduction target of 48% by 2020, and the national targets of 34% by 2020 and 80% by 2050. The principle aim is to maximise the installation of domestic retrofit measures by maximising the take up of new and future funding mechanisms such as the Green GM Low Carbon Housing Retrofit Strategy – discussion draft Greater Manchester Climate Change Strategy: http://www.agma.gov.uk/cms_media/files/gm_climate_change_strategy_final1.pdf 1 2 Deal, Energy Suppliers Obligation (ECO) and the local ‘Get me Toasty’ insulation scheme and to ensure that such investment produces both employment opportunities for its residents and starts to address the increasing issue of those in, or moving into, fuel poverty. The Retrofit Strategy endorses the ‘Fabric First’ model for this programme. 131263_City-South_Manchester_v5__ 19/03/2012 12:01 Page 5 1 2 3 Low Carbon Housing Retrofit Fabric first! The GM energy hierarchy approach 1. Investment should first be made to reduce energy use - by improving the building fabric of homes (e.g. insulation glazing and air tightness) and their fit-out (e.g. lights. appliances and sanitary ware) 2 Occupiers should be engaged to promote greater ‘carbon literacy’. This should form a part of all activities, and should be supported in each home by investment in energy monitoring devices and simple measures such as master switches. 3 Then investment can be made in reviewable energy technologies to supply the remaining energy needs (e.g. solar photovoltaics, biomass boilers). 5 Diagram from GM Retrofit Strategy draft The wide ranging research and standards review carried out for this report has led to the following conclusions and recommendations. These will enable a Common Standard and Framework of retrofit measures to be adopted across all areas and organisations in Greater Manchester, yielding substantial financial savings and a providing a pathway for achieving the local and national carbon emissions targets in the domestic housing retrofit sector. Image by kind permission of Energy Saving Trust The scope of this report is limited to the range of actions appropriate for the physical structure of the dwelling, which are seen as the critical first stage for the GM energy hierarchy as show in this diagram. Behavioural Change, Health/Fuel Poverty, and Skills/Training are addressed in other work groups as part of the overall Housing Retrofit programme. 131263_City-South_Manchester_v5__ 19/03/2012 12:01 Page 6 The report concludes that 1 With 1.1 million homes which are producing more than a third of the CO2 emissions in Greater Manchester, the developing Green Deal represents a significant opportunity for householders and landlords to improve the energy efficiency of their properties. This will contribute significantly towards the recently adopted Greater Manchester Climate Change Strategy target of 48% carbon emissions reduction by 2020, which exceeds the national target of 34%. 2 A review of the housing stock has identified nine major archetypes of properties to aid understanding of what is required. Low Carbon Housing Retrofit 6 3 A potential improvement required for each archetype to reach the national carbon emissions reduction targets of 34% by 2020 and 80% by 2050, has been identified in the form of a SAP rating linked to an Energy Performance Certificate and the associated carbon emissions per meter squared for that property type. 4 Each of these SAP target standards have then been analysed and a suite of energy efficiency measures designed appropriate to each archetype, identified as basic, intermediate (2020 target) and major interventions (2050 target). 5 A full evaluation of the cost and energy rating of each measure is provided in the technical appendices. 6 Crucially information is also included indicating the most efficient and cost effective order in which to install these measures using natural trigger points within the lifespan of the property and it’s ownership. Examples of these trigger points would include such works as a new roof, new windows, kitchen/bathroom upgrades or an extension. Lifestyle changes are also recognised as appropriate trigger points, including moving home, increased or reduced family size or occupancy. 7 It is recognised that property owners are unlikely to undertake a full retrofit of the property all at once; this document will help to ensure that an incremental ‘whole house’ approach is as efficient and cost effective as possible. 8 The levels of SAP/EPC/kg CO2 targets give property owners the option to upgrade the energy efficiency to the highest level possible during planned work to avoid potential wasteful and costly revisiting of the same areas later on when the higher levels are likely to be required. www.rethinkingrefurbishment.com http://www.decc.gov.uk/assets/decc/11/stats/energy/energy-efficiency/2078-need-data-framework-report.pdf 3 4 9 A range of specific building considerations are discussed to ensure users of this document are informed of key issues that are important in any retrofit planning. 10 It is made clear that in order to reach these very stretching national targets for 2050 all the properties which already exist in Greater Manchester will require some form of additional retrofit to ensure they meet the energy efficiency standards required to achieve the 80% emissions savings. 11 Development of a Greater Manchester web portal and database of these archetypes and retrofit solutions could effectively be linked to the Building Research Establishment (BRE) National Refurbishment Centre3 and the National Energy Efficiency Data-Framework (NEED)4. 12 Finally it is also acknowledged that some of the SAP/EPC/kg CO2 targets recommended will have to take advantage of newly developing technologies that may not be fully available yet in order to be cost effective. 131263_City-South_Manchester_v5__ 19/03/2012 12:01 Page 7 Recommendations Recommendations for this report were developed following the compilation of evidence by the GM Housing Retrofit Standards Group and the associated stakeholder seminar held in July 2010. The recommendations should be adopted to maximise the potential benefits of physical housing retrofit programmes and to endorse long term energy efficiency changes in behaviour. The following recommendations are made to inform those responsible for developing strategy and implementing domestic retrofit programmes in both the private and social sector. Recommendation Social Landlords • That Social Landlords should take into consideration the recommended SAP/EPC/kg CO2 standards when developing, tendering or managing retrofit schemes. • That they should also take these standards into consideration when preparing future asset plans and maintenance budgets. • To link these standards and targets to planned maintenance ‘trigger points’ such as kitchen/bathroom upgrades or new windows/roofs etc, to ensure effective long term cost efficiencies. • Take into consideration the items included in the specific considerations section when planning or tendering a project. Local Authorities • Local Authorities to recommend these SAP/EPC/kg CO2 standards to all social landlords, retrofit developers and private householders through the Planning and Building Control services. • To work with private landlords and Landlords Associations to promote the installation of measures to improve the energy efficiency for the private rented stock. This will include promotion through the landlords forums, the Greater Manchester Landlords Accreditation Scheme and where appropriate, active enforcement under the provision of the Housing Act 2004. • That householders be proactively made aware of these standards and opportunities for funding linked to the Green Deal/FITs/RHI etc when contact is made with the sustainability/housing or affordable warmth departments. Retrofit Developers • That developers, builders and designers include these standards in any retrofit schemes undertaken in Greater Manchester. • That the higher level standards are recommended to ensure effective long term cost efficiencies for the owners. • Be aware of the potential for linking Green Deal and other local and national funding to these standards. • Take into consideration the items included in the specific considerations section when planning or tendering a project. Scheme Managers • To ensure that these standards are embedded in the project management and work plans. • To be aware of the potential for reaching the higher standards when retrofitting at a natural ‘trigger point’, rather than costly revisiting at a later date. Homeowners • To use this document to help plan the most efficient and effective energy efficient retrofit programme for their home, to ensure an incremental ‘whole house’ approach is used where possible. • That these standards are included in the contract documentation for any scheme or project. • Take into consideration the items included in the specific considerations section when planning or contracting a project. Large scale Scheme Developers/ Installers • The Greater Manchester wide Get me Toasty scheme should take flood risk factors into account prior to recommending specific materials for CWI. • Low Carbon Housing Retrofit/LCEA committee. Low Carbon • To carry out an annual review of this report in light of developments in retrofit technology and funding models such as Housing the Green Deal. This will ensure that this document remains relevant and provides appropriate recommended standards Retrofit/LCEA up to 2020. • To monitor the developments in domestic energy efficiency and retrofit technologies and encourage trial pilot schemes board where appropriate. • To create the photo library of front elevations and develop the Greater Manchester Retrofit Housing Web Portal and Database to allow users to access the archetypes and measures packages as well as measuring progress towards the emissions reduction targets. Low Carbon Housing Retrofit Sector 7 131263_City-South_Manchester_v5__ 19/03/2012 12:01 Page 8 1. Developing a Retrofit Standard for Existing Housing Stock in Greater Manchester Background: the Greater Manchester context. A coordinated approach to improving existing housing stock is being developed and Greater Manchester’s Low Carbon Economic Area (LCEA) designation presents an opportunity to introduce a common standards framework for all domestic retrofit works throughout the conurbation. Low Carbon Housing Retrofit 8 This report has been prepared by the LCEA Housing Retrofit Standards Group, which reports to the Low Carbon Housing Retrofit Sub-Group of the LCEA Board and to the Association of Greater Manchester Authorities’ (AGMA) Environment Commission. Understanding the local housing stock will play a vital part in the success of the forthcoming basic energy efficiency measures programme, ‘Get me Toasty’, which seeks to treat 75% (approximately 400,000) of under-insulated lofts or un-insulated cavities by 2013 in Greater Manchester. This work provides a valuable opportunity to identify the total retrofit potential for the range of existing domestic properties, many of which were built before the new building regulations came into force, it will also ensure that the measures that are installed achieve their full energy saving potential. It will also be crucial when work is being planned that householders are given the opportunity to understand how to benefit from specifying and installing higher standards of insulation and energy efficient technologies, and at the same time being encouraged to think differently about their energy use to reduce demand. 5 Retrofit Strategy 2011 and Energy Saving Trust’s HEED database 2010 However, the longer-term ambition is to engage with the whole of the existing housing stock in order to reach the very ambitious national carbon emission reduction targets for 2020 and 2050. There are a total of 1.1 million homes in Greater Manchester, the majority (38%) of which consist of semidetached properties, followed by terraced (33%), flats or maisonettes (15%) and detached (14%) properties. Within this stock it is estimated that 25% of the stock is of solid wall construction and that there are still over 500,000 untreated lofts and cavity walls across Greater Manchester5. The Retrofit Strategy proposes a GM wide network of local showhomes and streets in every neighbourhood, where the notion of ‘seeing is believing’ will inspire take up of the Green Deal. How energy efficient is your home? 26% Loft Insulation Fit loft insulation and save around £110 and around 1 tonne of CO2 pa Loft 26% of heat lost from an uninsulated home is through the roof. Fitting sufficient loft insulation is one of the easiest and most cost effective ways of saving energy and money. Hot water tank Fit an insulating jacket around the hot water tank and save £20 and 160kg of CO2 pa Shower Thermostat Turn down the thermostat by 1˚C and save nearly £40 and around 325kg of CO2 pa Have a shower instead of a bath and use nearly two thirds less water and energy Fill gaps in floors Fill in gaps in floors and skirting and save around £15 and around 130kg of CO2 pa Windows Nearly a fifth of heat lost from an uninsulated home can be through windows. Double glazing can save around £90 and 700kg CO2 pa. 18% Boiler Appliances Upgrade to a condensing boiler and save a third on your heating bills and around 875kg of CO2 pa Turn TVs and other appliances off standby when not in use 33% Walls Walls leak more heat than any other part of the home – around a third in an uninsulated home. If your home has cavity walls, insulating them is the best way you can save energy and money. ESR fridge freezer Upgrading to an Energy Saving Recommended one can save up to £37 and 150kg of CO2 pa Draught proofing Washing Wash clothes at 30˚C rather than at higher temperatures and use a third less electricity, and so produces a third less CO2 Draught proof windows and doors and save £20 and around 155kg of CO2 pa Energy saving lightbulb One energy saving lightbulb will save £7 and around 45kg of CO2 pa 11% Doors and Floors Gaps around doors and floors account for around 11% of heat loss in an uninsulated home. Sealing up gaps will stop heat escaping. Cavity wall insulation Insulate cavity walls and save around £90 and around 750kg of CO2 pa Energy Saving Recommended For the most energy efficient products, always look for the Energy Saving Recommended logo. For more independent and impartial advice on energy saving in the home call 0800 512 012 or visit www.energysavingtrust.org.uk © Energy Saving Trust 2007. E&OE KEY Grants and advice available through Energy Saving Trust No-cost or low-cost measures 131263_City-South_Manchester_v5__ 19/03/2012 12:01 Page 9 The Group’s initial starting point has been to identify the most common housing types found within Greater Manchester. Then to apply an archetype grouping across three bands, against which the properties can be categorised. Against each archetype a brief description of the original construction details that are common to the age and materials used for that period has been given. It is recognised that subsequent individual improvements may have been carried out either through planned investment or by individual homeowners. Therefore, it will be necessary for all users to have their dwelling initially surveyed and assessed to establish the actual energy rating. The archetype list and measures set out in this report will assist the user to decide where their property currently falls with regard to the recommended measures described within these retrofit proposals. The initial physical upgrade of a property to improve energy performance will provide significantly enhanced thermal and financial benefits when combined with the behavioural changes described in another key Low Carbon Housing Retrofit report ‘The Missing Quarter’6. It is crucial that all retrofit schemes across Greater Manchester are complemented by awareness and behaviour change programmes to ensure that occupants of the improved properties understand and take full advantage of the upgrades made to their homes. Green Deal Guidance The Government’s Green Deal scheme aims to enable households to install home energy measures that are in part funded by a loan attached to the property rather than the household and repaid from savings in energy bills. The scheme has been driven by the need for a national comprehensive retrofit programme and carbon emission targets set for 2020 and 2050. In addition to its core aims, the Green Deal provides the potential to unlock not only a huge economic opportunity, but social benefits through warmer homes and mitigation of rising fuel Missing Quarter report: http://manchesterismyplanet.com/behavioural-change 6 costs, it also raises the prospect of local action where residents act together to bring about improvements to their homes and communities. In 2011, Greater Manchester was chosen by Government to trail-blaze a pilot for the Green Deal scheme within social housing ahead of its nationwide launch. GM has a social housing stock of over 260,000 properties and of these up to 25,000 fall in the ‘hard to treat’ category. The trailblazer will seek to establish delivery partnerships and supply chains to build customer confidence in the Green Deal. It will be essential that long term behaviour change support for householders is intrinsic to the Green Deal approach in order to achieve the best possible savings. The success of the Green Deal relies on the application of the ‘Golden Rule’ where customer repayments are always lower than the savings made though the energy efficiency works. The Golden Rule calculations will be based on assumptions and modelling. In its practical application it is critical that households adopt behaviour that will maximise the benefits of the physical measure to ensure that the anticipated savings are made. Low Carbon Housing Retrofit In July 2010 a stakeholder engagement seminar was held to assess the need for a Greater Manchester Retrofit Standard in response to local and national developments. From this the LCEA Retrofit Standards Group was formed and tasked with the development of this standard, through the identification of property types, measures and the options for the potential improvement in energy performance of a dwelling. The range of measures identified has been developed to apply across the majority of property archetypes. Many other factors such as location, conservation status, occupation etc will affect the identified measures recommended. These factors are discussed in the GM Retrofit Strategy and the GM Green Deal Intelligence report which will be published in the near future. Image by kind permission of Energy Saving Trust The Challenge for the Retrofit Standards Group 9 131263_City-South_Manchester_v5__ 19/03/2012 12:01 Page 10 A full discussion of the Green Deal requirements and data intelligence is included in the GM Green Deal Intelligence report which will be published in the near future. Green Deal Criteria7: Low Carbon Housing Retrofit 10 The first is called the “Golden Rule”; it states that the measures recommended must produce sufficient savings on the annual energy bill to pay back the initial cost of carrying out the works. • The identified measures must be approved so that the claimed bill savings can be those accredited to pay back the loan. • The provider of the loan must give appropriate advice under the terms of the Consumer Credit Act, under which the individual’s circumstances shall be taken into account. • The loan stays with the property not the individual, so is paid back as part of the future energy bills. • The present energy provider must be informed of the proposed measures before the funds are released to undertake the works. • The measures recommended should be identified by an accredited Domestic Energy Assessor “DEA” who has undertaken an Energy Performance Certificate on the property, or be based on the recommendations contained within an existing Energy Performance Certificate which has been lodged by a DEA. An objective adviser can be used, if appropriate. • The loan must be paid back before the measures undertaken have reached their replacement date, this can be up to 25 years. • Only accredited installers/contractors will be allowed to undertake the recommended measures, or installations, for the funds to be released under the Green Deal offer. • Any Green Deal provider must have consent from all relevant parties, including the express consent of the current energy bill-payer. • Properties should have the basic energy efficiency measures undertaken prior to implementing the high tech solutions for maximising energy income. • The presence of a Green Deal charge must be properly disclosed to all future occupants whether through selling or offering the property for rent. Department of Energy and Climate Change: http://www.decc.gov.uk/ Energy Saving Trust: http://www.energysavingtrust.org.uk/ 7 • There is a move at Government level to look at how micro-generation income can subsidise retrofit. These measures have been put in place to protect residents and will ensure that only works appropriate to reducing the property’s overall energy demands will be approved under the Green Deal. The GM Housing Retrofit strategy is being developed in advance of the launch of the Green Deal will support this by identifying the most effective and appropriate combinations of measures, assembled into packages, for the different property types. The level of retrofit activity is being monitored by proactive information gathering across the region regarding the property types and the measures installed in them over time, which in turn will enable the retrofit packages to be updated and refined. Image by kind permission of Energy Saving Trust Under the current proposals for Green Deal the Government has set certain criteria which must be met in order for the finance to be made available, which protects the resident from committing themselves to undertaking uneconomic measures within their homes. These criteria are subject to confirmation by the end of 2011. Further information will also be made available regarding the role of social housing providers and the criteria for social housing tenants in relation to the Green Deal. Retrofit Finance models: Potential financial savings from retrofit installed measures As well as the Green Deal a new Energy Company Obligation (ECO) fund is under development which will be a replacement to the existing Carbon Emissions Reduction Target (CERT) and Community Energy Saving Programme (CESP) funds. A range of other retrofit funding is available for renewable technologies such as the Feed in Tariff (FiT) and Renewable Heat Incentive (RHI). It is the intention that all appropriate retrofit funding should be maximised across Greater Manchester and that all schemes should be encouraged to meet the common standard and framework proposed in this report. Residents can achieve substantial savings on their annual energy bills by installing a range of measures, some of which are shown below: In addition to national funding programmes, Greater Manchester has developed the local ‘Get me Toasty’ insulation scheme which provides free cavity wall and loft insulation to the majority of private sector households, subject to survey. This programme aims to install 400,000 basic measures by 2013. Indicative Measures (figures for 2010) Approx savings Payback time (£/year)8 (years)9 Cavity wall insulation 110 2 Full Loft insulation 150 1 Loft insulation top-up 45 6 New “A” rated Condensing Boiler 225 8 – 11 Voltage optimisation 35 13 Internal solid wall insulation 365 15 – 23 External solid wall insulation 385 27 – 38 Solar Panels (water) 75 33 – 46 Ground Source Heat Pumps 125 36 – 48 Photovoltaic PV (electric) 92 41 – 60 Double Glazed PVCu Windows 85 41 – 53 Low Carbon Housing Retrofit Image courtesy of Creative Concern 131263_City-South_Manchester_v5__ 19/03/2012 12:01 Page 11 Heat Recovery from Air (MVHR) 75 46 – 60 11 PVCu insulated Doors 15 50 – 57 The above table sets out estimated potential savings for introducing these measures within the home (based on a 3 bed semi detached house). It should be noted that savings cannot be simply added together where multiple measures are being installed, because the savings from measures are interdependent. Individuals should be mindful that the performance of the actual measures as noted in the table above will be subject to a range of factors such as the size of property, occupancy and individual preference for heating their property. The savings shown have been developed 8 These figures are based on the Department for Energy and Climate Change (DECC), Building Research Establishment (BRE) and the Energy Saving Trust’s (EST) advice. All the savings figures are based on a 3 bedroom semi detached property.: (http://www.energysavingtrust.org.uk/business/Business/Information/Energy-Saving-Statistics/Energy-Saving-Assumptions) These payback periods are based on 2010 fuel prices and are likely to become shorter as fuel prices increase 9 from work done by the Energy Saving Trust (EST) and Building Research Establishment (BRE) along with other material used within this report. Further information on a wide range of energy efficiency work and advice is available through accessing their web sites shown below: www.energysavingtrust.gov.uk www.bre.co.uk 131263_City-South_Manchester_v5__ 19/03/2012 12:01 Page 12 Aims of the report It is intended that this report will enable all users, from individual householders to large scale landlords and those involved in planning and installing retrofit measures, to understand the potential range of energy efficiency measures that may be fitted to their properties and the most efficient order in which to install them. In addition to applying the basic and intermediate measures the user’s opportunity for saving money by reducing their ongoing energy usage is highlighted. These recommendations and packages of measures are linked to the local 2020 Greater Manchester Climate Change Strategy emissions saving target of 48%, and the national targets of 34% by 2020 and 80% by 2050. 12 Image from ‘The Missing Quarter’ Low Carbon Housing Retrofit This work has been undertaken through the Low Carbon Economic Area Domestic Retrofit programme in order to offer recommendations and advice on the potential of energy efficiency measures that can benefit all the properties within the Greater Manchester area. The main archetypes and their recommended measures are described in this report to assist users in identifying the present condition and likely energy efficiency of their properties and the potential improvements and savings which can be achieved by investing in the recommended measures. The principle objective is to provide clear realistic targets for typical property types within Greater Manchester and a range of clear, simple and increasingly cost effective retrofit package options for our residents, landlords, developers and installers, by bringing together a range of services that will ensure they receive the best advice and support. Creating these local archetype standards and retrofit package options for 2020 and 2050 will meet the challenges set out in the LCEA Low Carbon Housing Retrofit Strategy. It is anticipated that Greater Manchester will provide a lead both locally and nationally in driving down the levels of domestic emissions in line with or ahead of the national timescales. Decision Making As well as the physical retrofitting information in this report a range of further support and advice is available from the wider AGMA domestic retrofit programme work being undertaken. It is intended that users will be able to access the following: • Guidance on how to best ensure that behavioural change programmes are effective and properly integrated into retrofit projects as described in the ‘Missing Quarter’ report. • Obtain objective advice on retrofit standards and appropriate measures to be undertaken as described in this report and in the Retrofit Strategy. • Support through Greater Manchester’s approach to Green Deal: • AGMA is working towards creating the most appropriate delivery programme for Green Deal for the conurbation through the establishment of a Greater Manchester Green Deal partnership/framework designed to give confidence to consumers and strategic direction to activity. This approach will provide access to: • An independent, impartial and expert customer advice service that can support the customer journey and promote most appropriate retrofit project approaches. • Accredited suppliers whose materials and performance meets the required specifications and standards. • Accredited installers/contractors whose operatives are appropriately trained to undertake these works and installations within the home. • The best market prices for guaranteeing both materials and workmanship. • Installers/contractors who can if needed provide servicing and maintenance support, if called upon. • Guarantees that will be honoured by both suppliers and installers. 131263_City-South_Manchester_v5__ 19/03/2012 12:01 Page 13 Potential Low Carbon Economic and Social Benefits Our aim is to put every representative home type in the area on a database accessible through a web portal, so it can be assessed against this GM Housing Retrofit Standard, to highlight the most cost and energy efficiency interventions based on property type and other stock intelligence. This database will also allow forward planning of any retrofitting work so that when homes change hands future householders or managers will be able to pick up where the previous ones left off. A core ‘grid’ of 9 principle types of properties and approximately 24 types of interventions have been identified and developed into retrofit option packages linked to the national 2020 and 2050 emissions reduction targets. This will enable adoption of these standard packages as a Greater Manchester core programme of improvements to homes, providing the AGMA ‘family’ of organisations with a common framework within which to maximise a range of low carbon economic and social benefits including: • Provision of business assistance to Construction SMEs (small and medium enterprises) located within the conurbation to maximise the capacity of local firms to bid for and undertake the works. • Understanding of the range of interventions that will help make best use of local existing and potential sources of Construction Products. This will help to minimise the environmental impact during the manufacturing and transporting stages, and to maximise the local economic impact and its multiplier effects. • The option packages will hopefully enable the supply chain to develop with more confidence about the future and the capacity needed. • Greater Manchester’s wide sharing of best practice and intelligence on the regional supplier base will enable these packages to be updated and remain relevant. • Working with local colleges, and with area teams focussed on assisting NEET (not in employment, education or training) young people to provide additional incentives to develop and join Construction Courses for successful sandwich placements and improved job prospects. • Providing a focus on ‘entry level’ construction work opportunities particularly for families with complex needs and with inter-generational unemployment, as a supported package with college and mentoring. • Developing an understanding of households in fuel poverty (see below) and using this to inform the strand of the forthcoming Green Deal programme which will allow for the PAYS (pay as you save) principle to be subsidised by public funds. • To place this framework of specific interventions in the public domain, with the stability of commitment from across the range of Greater Manchester organisations, as a resource to other private sector investors in the Domestic Refurbishment market, including ‘green mortgage’ providers and other substantial fund holders and investors. The opportunities to realise the economic potential of the Green Deal in Greater Manchester are further discussed in the GM Housing Retrofit Strategy. Fuel Poverty. The existing Government’s definition of fuel poverty is when a household spends 10% or more of its income on fuel costs; however a new definition is under development. Fuel poverty is an issue that disproportionately affects households on low incomes and can severely impact on the health and wellbeing of vulnerable households, and in particular the elderly. Improving the energy efficiency of properties will assist greatly in minimising the health and financial impacts of fuel poverty. Certain national funding streams have been available to target Fuel Poverty, with the new Energy Company Obligation (ECO) due to replace the existing Community Energy Saving Programme (CESP) next year. Low Carbon Housing Retrofit It is expected that residents, landlords and owners who wish to consider the Green Deal offer for their property will find this suite of advice and guidance helpful. It is further hoped that the user will decide to use The Greater Manchester Green Deal Partnership network of selected independent and objective advisors to support accessing the Green Deal and other funding options, administration of the works and procurement of the recommended retrofit measures. 13 131263_City-South_Manchester_v5__ 19/03/2012 12:01 Page 14 Energy Performance Certificate10 The principle tool for assessing a dwelling’s energy efficiency performance is the Standard Assessment Procedure “SAP” which categorises the dwelling using seven band ratings from “A”, the best performing, to “G”, the worst performing, and is normally displayed on an issued Energy Performance Certificate (EPC). The title for this document is ‘Transforming homes from G to A’ based on this improvement of energy efficiency SAP rating which will be required from all domestic properties to meet the GM national emissions reduction targets. The Retrofit Strategy indicates that to achieve the national standards for 2050 across Greater Manchester 90% of all homes will need to achieve an average of band B. The EPC certificates also show a variety of useful information relating to a dwelling; from its actual energy rating together with its An Energy Performance Certificate display showing the proposed improvements in SAP banding is shown below. If the dwelling has had an EPC assessment undertaken to establish its SAP rating, as an initial starting point for planning any retrofit works the EPC certificate should be viewed to evaluate the current status and review the potential measures recommended for improving the energy efficiency. At the time of writing this report the Government is currently looking at introducing a new layout for the EPC certificate, which will provide clearer advice to the owner on what initiatives can be undertaken to enhance their properties overall energy performance and the savings that would result. Current Potential A B Diagram from GM Retrofit Strategy draft Source: DCLG Low Carbon Housing Retrofit 14 potential rating should the owner take action and invest in the recommended measures listed in the accompanying report. Summary The opportunity provided by both the local GM and national emissions reductions targets and the development of funding mechanisms such as the Green Deal, Energy Company Obligation, FITs and RHI and local ‘Get me Toasty’ scheme has led to the development of a range of work packages for Low Carbon Housing Retrofitting. It is seen as important and economically astute to encourage all ten authorities and all organisations in Greater Manchester to work to a common framework of targets, standards, methodologies and timeframes. It is recognised that interventions through works only will not address the behavioural changes necessary to ensure that the occupants achieve the full potential savings on their energy bills and that advice and support are therefore also key factors in reducing emissions. It is recommended that a Greater Manchester housing stock database and web portal be developed to keep track of improvement and to allow owners to search for their house type and the most effective measures packages. 90% of stock C 10% of stock D GM average E F 10 http://www.direct.gov.uk/en/HomeAndCommunity/BuyingAndSellingYourHome/ Energyperformancecertificates/index.htm G Proposed Greater Manchester EPC Targets 131263_City-South_Manchester_v5__ 19/03/2012 12:01 Page 15 The journey of improving solid walls with insulation During After Low Carbon Housing Retrofit Before 15 Before During After It’s not just about improving energy efficiency is it? 131263_City-South_Manchester_v5__ 19/03/2012 12:01 Page 16 2. Housing Retrofit potential in Greater Manchester. Property Archetypes The initial approach taken by the Retrofit Standards Group has been to categorise the representative property types throughout the GM area into set archetypes groupings. The 9 most common GM property types have been identified. Archetypes 1 to 8 represent over 95% of the housing stock11, less common, non traditional property types have been put together in Archetype 9. This approach ensures that the original construction standards for each type are accounted for and appropriate to the retrofit package options being recommended. Categorisation of Wall types Solid Wall (Generally all pre 1919 housing) Cavity Wall (Generally all brick built post 1919) All ‘non traditional’ construction Mid – terraced 1 5 9 Semi-detached/end terraced 2 6 9a Detached 3 7 9b All flats 4 8 9c Identification of Property Types Low Carbon Housing Retrofit 16 A library of photographs of typical front elevations is being collated to assist in identifying the dwellings classifications listed in the archetypes. This approach has enabled the Retrofit Standards Group to ensure it has included as many of the representative archetypes across the GM area as possible. The aim is to establish a web portal where you will be able to view this library by accessing a Greater Manchester Low Carbon Economic Area website to help identify the correct house type category and package of retrofit options for your property. A brief description of archetypes 1-9 is shown below and on page 17 for reference purposes: Archetype 1 pre 1919 Typical property: ‘Victorian’ 2 storey pre 1919 mid terraced house, brick built with 225 mm walls and a slate roof. Includes: All solid wall construction mid terraced housing including ‘finger cavity’ stock brick walls, and larger 340 mm solid walls. As a general rule, this would include all terraced property built before 1919. Archetype 2 pre 1919 Typical property: ‘Victorian’ 2 storey pre 1919 ‘end of’ terraced house or small semi-detached, brick built with 225 mm walls and a slate roof. Includes: All solid wall construction end of terrace/semi – detached housing, including ‘finger cavity’ stock brick walls, and larger 340 mm solid walls. As a general rule, this would include all semi- detached/end terraced property built before 1919. Archetype 3 pre 1919 Typical property: Large ‘Victorian’/’Edwardian’ detached house, brick built with 225 mm or 340 mm walls. Includes: All solid wall construction detached housing, including ‘finger cavity’ stock brick walls, and larger 340 mm solid walls. As a general rule, this would include all detached property built before 1919. http://data.gov.uk/dataset/english_house_condition_survey 11 131263_City-South_Manchester_v5__ 19/03/2012 12:01 Page 17 Archetype 5 pre 1961 Archetype 6 1937 Typical property: Converted Large ‘Victorian’/’Edwardian’ house, brick built with 225 mm or 340 mm walls. Typical property: 1960’s ‘town house’ with 275 mm cavity walls. Typical property: 1930’s ‘inter war’ semi detached house with 275 mm cavity walls. Includes: All cavity wall properties, including properties with partial cladding, and tile hung bays. As a general rule, this would include all mid terraced properties built from 1920 up to 2000. Includes: All cavity wall properties, including properties with partial cladding, and tile hung bays. As a general rule, this would include all semi detached/end terraced properties built from 1920 up to 2000. Includes: All flats in buildings of solid wall construction individually evaluated. Low Carbon Housing Retrofit Archetype 4 pre 1919 17 Archetype 7 1930 Archetype 8 pre 1955 Archetype 9, 9a, & 9b 1974 Typical property: 1930’s ‘inter war’ detached house with 275 mm cavity walls. Typical property: 1950’s ‘low rise’ brick built flats, with 275 mm cavity walls. Typical property: 1960’s ‘non traditional’ low rise construction. Includes: All cavity wall properties, including properties with partial cladding, and tile hung bays. As a general rule, this would include all detached properties built from 1920 up to 2000. Includes: All cavity wall properties, including properties with partial cladding, and tile hung bays. As a general rule, this would include all low rise brick built flats constructed from 1920 up to 2000. Includes: All non traditional construction, including ‘system built’ properties such as Wimpey ‘no-fines’ Reema hollow panel, high rise concrete frame flats, and timber framed housing. Archetype 9c Typical property: Medium and High rise flats 131263_City-South_Manchester_v5__ 19/03/2012 12:01 Page 18 Options for Improvement through Identified Measures For each property archetype three approaches have been identified depending on the extent and standard to which the properties are to be improved, these are linked to the national emissions reduction requirements for 2020 and 2050. The Standard options are: • Basic Measures • Intermediate Measures (2020 Standard) • Major Measures (including new technology) (2050 Standard) After Major Measures 2050* SAP/EPC Band /kgCO2/m2 Archetype 1 SAP 1 band G CO2 1 <1900 mid/terraced house with solid wall SAP 57 band D CO2 46 SAP 66 band D CO2 61 SAP 87 band B CO2 84 Archetype 2 SAP 1 band G CO2 1 <1900 end/terraced house with solid wall SAP 55 band D CO2 49 SAP 64 band D CO2 59 SAP 83 band B CO2 80 Archetype 3 <1900 large detached house with solid wall SAP 1 band G CO2 1 SAP 52 band E CO2 46 SAP 66 band D CO2 61 SAP 80 band C CO2 76 Archetype 4 Converted 1900-29 large detached house with solid wall SAP 1 band G CO2 1 SAP 56 band D CO2 50 SAP 78 band C CO2 76 SAP 87 band B CO2 85 Archetype 5 SAP 48 band E CO2 43 1960 mid terraced house with cavity walls including those with tile hung bays SAP 64 band D CO2 60 SAP 72 band C CO2 70 SAP 88 band B CO2 86 Archetype 6 SAP 1 band G CO2 1 1930 Semi detached house with cavity walls including those with tile hung bays SAP 61 band D CO2 55 SAP 72 band C CO2 68 SAP 85 band B CO2 82 Archetype 7 SAP 1 band G CO2 1 1930 detached house with cavity walls including those with tile hung bays SAP 56 band D CO2 50 SAP 69 band C CO2 64 SAP 82 band B CO2 78 Archetype 8 1950 low rise cavity brick built flats SAP 69 band C CO2 66 SAP 71 band C CO2 67 SAP 77 band C CO2 73 SAP 94 band A CO2 92 Archetype 9, 9a, 9b, & 9c SAP 53 band E CO2 49 1960 system built mid/terraced wimpy no-fines etc SAP 63 band D CO2 57 SAP 71 band C CO2 67 SAP 85 band B CO2 81 *All figures use NHER Stock Assessor calculations Low Carbon Housing Retrofit The table below shows the “as built” SAP rating and related EPC band for each archetype. It shows the level of improvement that each requires to meet the 3 standards. After Basic Measures* After intermediate Measures 2020* SAP/EPC Band SAP/EPC Band /kgCO2/m2 /kgCO2/m2 Type 18 Basic and intermediate measures, as their name implies will not be sufficient to meet the national 2050 target meaning that the properties will have to be retrofitted at least once more before then. As Built* SAP/EPC Band /kgCO2/m2 131263_City-South_Manchester_v5__ 19/03/2012 12:01 Page 19 It is apparent from the above table that especially with the older stock; it may not be possible to achieve the set standards by 2020 without major investment being made. The three recommended Basic, Intermediate and Major Standards measures identified when implemented will impact on SAP/EPC/kg CO2 levels. They have been broken down into sub group elements to help users decide where their property is in relation to the works being recommended. This will also help to identify whether the investment will be cost effective in the longterm and help to reduce the user’s potential future energy costs. Specifications for these retrofit package options can be found in Technical Appendix A. This sectional view of a property shows what can be done in order to enhance the energy efficiency of a property. Specific details for these elements are listed within each of the Basic, Intermediate and Major retrofit options packages. It is important to realise that not all the work is likely to be carried out at one time, but will be best undertaken when a natural ‘trigger point’ is reached eg when work is being carried out such as new kitchen/bathroom or roof or when family numbers change. A Solar thermal or photovoltaic panels B Full Loft insulation & Top up C Internal heat recovery unit D Low energy light bulbs E Ventilation extractor fan F Double or triple glazed windows Low Carbon Housing Retrofit Users will also need to consider when this investment is to be made on a property and how best it will contribute to the 2050 targets. These aim to reduce the average home’s CO2 emissions from 6 tonnes down to only 1.5 tonnes per year, to meet the overall 80% reduction targets set by the Government for 2050. Retrofit potential property overview G Hardboard laid over floors & sealed skirting boards to prevent drafts 19 H External walls, see treatment potential in the Technical Appendix I Insulated door and frame fitted J Voltage optimisation meter fitted to electric distribution board K Timber floor overlaid with hardboard & sealed skirting boards to stop drafts L Insulation fitted externally to prevent cold bridge M Solid floor renewed with insulation layer installed N External garden used for ground source heat recovery or alternative use air source heat recovery units Diagram courtesy of City South Manchester Housing Trust The NHER Assessor software used to develop these target standards is based on reduced SAP (RD SAP) which relies on approximations and assumptions. Calculations carried out using full SAP methodology may therefore be different and are likely to be more accurate. 131263_City-South_Manchester_v5__ 19/03/2012 12:01 Page 20 Basic Measures These works will improve the energy efficiency of the properties and reduce energy usage and the expenditure on fuel bills and should be considered as a minimum first stage for retrofitting. Although not part of the building fabric, installation of energy efficient ‘A’ rated appliances should also be an intrinsic part of any basic retrofit project. Reduced infiltration Loft Insulation Cavity wall insulation Reduced flow hot water fittings Primary pipework insulation Thermostatic radiator valves Energy saving light bulbs Draught proofing Diagram courtesy of EST Low Carbon Housing Retrofit 20 Roofs Pitched Roofs Pitched roofs insulated at ceiling level minimum 270mm. Target U-value max ~ 0.16W/m2K Pitched roofs insulated at Rafter level Target U-value ~ 0.18W/m2K. Flat Roofs Usually upgraded as part of a re-roofing project. Target U-value ~ 0.18W/m2K Walls Cavity Walls Cavity fill. Performance dependent on cavity width and materials. Target U-value ~ 0.58W/m2K Draught proofing/Ventilation Provide basic sealing measures around windows and doors, walls, floors, roofs and around service entry points and loft hatches maintaining background ventilation requirements. Install extraction fans to the current Part F of the Building Regulations. Heating Controls Central heating systems to be interlocked and controlled by a programmer with separate channels for heating and hot water; a cylinder thermostat; TRVs. Low Energy Lighting Install 100% low energy lighting 131263_City-South_Manchester_v5__ 19/03/2012 12:01 Page 21 Intermediate Measures linked to 34% 2020 national emissions targets and the 48% Greater Manchester target. These measures fit into packages that will make the most sense together both to avoid repeat work but also ensure maximum energy and cost efficiency for each measure. Roofs Pitched roofs insulated at ceiling level. Target U-value ~ 0.1W/m2K. Flat Roofs Usually upgraded as part of a re-roofing project. Target U-value ~ 0.12W/m2K Walls Solid External Walls Internal insulation. Performance dependent on system. Target U-value ~ 0.25W/m2K External insulation. Performance dependant on system. Target U-value ~ 0.2W/m2K Cavity Walls Cavity fill and internal insulation. Performance dependent on cavity width and materials. Target U-value ~ 0.2W/m2K. Cavity fill and external insulation. Performance dependent on cavity width and materials. Target U-value ~ 0.16W/m2K Windows and Doors New energy efficient windows and doors. Target U-values Windows ~ 0.6-1.2W/m2K, Doors 0.8-1.2 W/m2K. Ground and Exposed Floors Suspended timber (access and scope of works dependent) Possible insulation between the joists and draught proof. Target U-value ~ 0.25W/m2K Ground Supported Slabs – overlay insulation. Performance dependant on system. Target U-value ~ 0.25W/m2K Perimeter Trench insulation. Performance dependant on system. Target U-value ~ 0.45W/m2K Thermal Bridging Minimise the effects of thermal bridging by careful detailing. Draught proofing/Ventilation Draught proof to a target of 5m3/hr at 50Pa. Install low energy extract fans Heating Systems/Controls Upgrade gas boilers to “A” rated condensing incorporating a flue gas heat recovery unit and high efficiency hot water system. Controls - as for Basic Measures and use of a weather and/or load compensator Low Carbon Housing Retrofit Pitched Roofs 21 131263_City-South_Manchester_v5__ 19/03/2012 12:01 Page 22 Solar water heating Solar Photovoltaic Major Measures (Including new technology) – linked to 80% 2050 national emissions targets. While these measures can be more expensive or disruptive, the possibilities of revenue generation from some of these measures will mean that in some circumstance they should be considered earlier. Loft insulation High performance insulated DHW cylinder Triple Glazing Reduced/ Sensor flow hot water fittings Reduced infiltration Air source heat pumps, (or ground source heat pumps in larger properties) Primary pipework insulation External wall insulation Energy saving light bulbs Thermostatic radiator valves Draught proofing Diagram courtesy of EST 22 Low Carbon Housing Retrofit Cavity wall insulation Ground and Exposed Floors Replace existing ground floor. Target U-value ~ 0.12W/m2K Draught proofing/Ventilation Draught proof to a target of 3m3/hr at 50Pa. Install whole house ventilation either using passive stack, or mechanical ventilation with heat recovery minimum 85% efficient. Renewables Install Solar Thermal system Install PV System Individual / communal biomass boiler/ heating Install a ground/air source heat pump Community heating and combined heat and power Install a micro CHP system (combined heat and power) Install a waste water/heat recovery system The Technical appendices include additional information and recommendations on the range of measures appropriate for your property. These recommendations should be considered when drawing up the property data sheets for identifying the appropriate treatment to maximise the opportunities under the different funding models such as the Green Deal and local Get me Toasty scheme. 131263_City-South_Manchester_v5__ 19/03/2012 12:01 Page 23 Summary Analysis of the potential for thermal efficiency improvements across the GM housing stock has identified the following: • Nine specific archetypes have been identified as the most prevalent across the Greater Manchester housing stock. • These standard levels have been designed to match the national 2020 and 2050 emissions reductions targets. • Basic, Intermediate and Major Packages of measures have been identified for each archetype as it was originally built. It is recognised that property owners are unlikely to undertake a full retrofit of the property at the same time. This document will help to ensure that an incremental ‘whole house’ approach is as efficient and cost effective as possible. Low Carbon Housing Retrofit Based on the range of 9 archetypes described on page 18, using the as built wall specifications for the period of construction, a range of wall treatments have been shown in Technical Appendix B. The measures described in the table enable the user to assess the impact of the basic and intermediate treatment measures on the walls U-values once installed. These are not by any means exhaustive and in the short to medium term advice should be sought from appropriate design professionals before selecting the optimal solution for a given situation. As the GM stock intelligence data is built up a greater body of evidence of what works in these situations will be available. Eventually users will be able to select solutions from this stock intelligence database via the web portal discussed earlier. • Target standards for SAP level linked to EPC band and kgCO2/m2 are then defined for three levels of retrofit intervention – Basic, Intermediate and Major. 23 Image by kind permission of Energy Saving Trust Wall Types and Appropriate Treatment 131263_City-South_Manchester_v5__ 19/03/2012 12:01 Page 24 3. Specific Considerations Building Regulations and Planning A further consideration for the designer and/or property owner, when looking at any treatment to external walls, is to take into account the impact the proposed treatment on the existing structure and whether it will meet current Building Regulation requirements. As a rule of thumb, if the treatment covers more than 25% of the wall area then Building Regulation requirements will apply; if in doubt check with your local Building Control Officer, prior to applying any treatment. Low Carbon Housing Retrofit 24 Whilst our attention in this report is focused primarily on wall treatments, this rule of thumb applies equally to the upgrading of other ‘retained thermal elements’ such as floors and roofs. Improvement works affected by Building Regulation control include replacement windows, external doors with more than 50% glazing, installation of central heating boilers and/or wood burning stoves, new/replacement electrical wiring, and the installation of renewable technologies. Building Regulation requirements are broken down in two parts, procedural and substantive. The procedural requirements in this instance would be to either use accredited contractors registered on a nationally recognised ‘Competent Persons Scheme - thus allowing them to self certify that their works comply, or to seek approval directly from a Building Control body. The substantive element is simply a matter of ensuring that the treatment works meet the functional requirements of Part L of the Building Regulations, details of which are outlined in the supporting guidance that is Approved Document L1B. It should be noted that where approval under Building Regulations becomes necessary, charges will be applicable for determining compliance, unless the work is undertaken under the auspices of a ‘Competent Persons Scheme’. The on-going intelligence gathering of improved Greater Manchester properties will not only assist those carrying out the work, the pattern book approach that it will develop will also assist Building Control. As they will not only be able to contribute to this body of evidence it will also prove invaluable in assessing applications to ensure that as the pace of retrofit picks up it will not be held up by the statutory procedures. Planning permission may also be required, particularly for measures that would involve changes to the external appearance of the property. Advice should be sought from the local authority. Risk From Flood Damage The environmental impact of the risk of flooding is an important consideration when considering any treatment to cavity walls. Flood risk levels for a property can be found at www.environment-agency.gov.uk • select the “Home and Leisure” list and • select “What’s in your backyard“. • From here you can go straight to a map and • enter your “post code” where you will find clear guidance on the likelihood of flooding damage to your property and in the local area in general. 131263_City-South_Manchester_v5__ 19/03/2012 12:01 Page 25 Risk from Fire In England all External Wall Insulation systems must meet the requirements of the Building Regulations approved documents B1 (Fire Safety - dwellings) Section B4 (8). This document can be found at the following link: http://www.planningportal.gov.uk/uploads/br/ BR_PDF_ADB1_2006.pdf http://www.inca-ltd.org.uk/pdfs/INCATechnical-Guide-01-Fire-PR-for-EWISystems.pdf Photo courtesy of Property Tectonics The Greater Manchester Get me Toasty campaign, which promotes Loft and Cavity Wall Insulation to private householders, should identify flood risk properties as part of its delivery process and recommend suitable materials for the affected properties. Further guidance and material specifications is offered by the Insulated Render and Cladding Association (INCA): Interstitial and Surface Condensation Condensation is a modern phenomenon affecting approximately 15% of homes in the UK (BS 5250) and its effect is generally greater in post-war housing. Condensation must not be confused with dampness due to water penetration from the outside or dampness caused by the normal drying out of a new building. Condensation, like all forms of dampness, is a particular problem because damp homes are ‘harder to heat.’ Surface condensation can occur when water vapour, usually from occupants and their activities condenses on an exposed surface or interstitial condensation where it is within the fabric. Air containing a large amount of water vapour has a higher vapour pressure than drier air and therefore moisture from the wetter air disperses towards drier air. This means that the concentration of moist air in a kitchen or bathroom easily disperses throughout a dwelling and the moist air at higher pressure inside a dwelling tries to escape by ventilation and through the structure where it may condense within it. Air at all temperatures absorbs moisture and the higher the temperature is the more moisture it can contain. This air will reach a state when it cannot absorb any more and it will have therefore have reached saturation point. Condensation will occur when the warm moist air is cooled to its ‘dewpoint’ temperature, either by being brought into contact with cold surfaces or by passing into a cooler part of the building. Condensation will also occur on absorbent surfaces but will not always show until the surface is very damp. In these cases mould growth can occur consisting of black patches which will cause deterioration of decorative finishings and potentially health problems for residents. This type of growth can also form on clothing and shoes etc. stored in unventilated and un-heated built in cupboards. Low Carbon Housing Retrofit A range of materials are available for insulating cavity and solid walled properties. Some are more suitable than others in areas of high flood risk, for example; blown mineral fibre filled cavities, if affected by flood water will need to have the fibre removed to enable the drying out process to occur. Properties that are situated in flood risk areas should be insulated with alternative materials such as bonded EPS beads which drain freely or injected PUR expanding insulation which can assist in providing an effective water barrier as an integral part of the existing wall construction. Guidance from the product manufacturer should be sought prior to installation and consideration given to the breathability of the resulting wall. 25 131263_City-South_Manchester_v5__ 19/03/2012 12:01 Page 26 The occurrence of condensation is influenced by a number of factors: 1. The number of occupants and their behaviour; 2. The type of dwelling and its construction; 3. Heat levels maintained in the property; 4. Type of heating; 5. Length of time the property remains unheated; 6. Level of insulation and airtightness; 7. Amount of ventilation and Low Carbon Housing Retrofit 26 8. Prevailing weather conditions. To reduce the risk of condensation attention should be given to improving ventilation, insulation or heating, or a combination of them. Checklist of considerations: • Check that condensation is the cause of the dampness problem. • Improve insulation or its continuity particularly if mould growth is associated with cold bridges e.g. uninsulated lintels. This is obviously more expensive than ventilation but the main aims are to keep surface temperatures above dew point. This measure is linked to heating as insulation without a suitable heat input will not provide a satisfactory remedy. Double glazing windows will reduce the occurrence of surface condensation. • Provide extract ventilation preferably at source and possible with humidistat controlled extractor fans in kitchens and bathrooms. A limited amount of ventilation is essential to keep the relative humidity below 70%, achieving a level below 55% will also ensure that dust mites are eliminated. Ventilated hoods above cookers are particularly useful in extracting steam generated by cooking. Kitchen and bathroom doors should be well fitting to prevent moist air entering cooler rooms. The amount of openable window (where provided) should be in line with part F of the current Building Regulations. • Ventilate unheated internal stores on external walls. • Provide background ventilation by e.g. trickle ventilators. • Advise occupants about activities that can promote condensation and mould growth e.g. flue less heaters, unvented tumble driers, excessive indoor clothes drying, and failure to use/blocking off ventilators. Clothes drying should be in heated and well ventilated spaces. References in Appendix C Ventilation and Building Physics Diagram courtesy of EST When a property is retrofitted to make it more energy efficient, by improving air tightness to prevent heat loss along with high levels of wall insulation, there is a need to consider the flow of moisture through and out of the building. Adequate ventilation is essential to ensure that condensation does not become a problem either within the building fabric (a) or within the rooms (b). a. Moisture trapped and condensing within the building roof or walls is known as interstitial condensation and can cause rot, mould and fungal growth. Calculations should be carried out to ensure that this does not happen. There are some circumstances such as in stone buildings and some solid wall properties 131263_City-South_Manchester_v5__ 19/03/2012 12:01 Page 27 where it is advantageous to the building fabric for materials to be used that allow moisture to pass through them. The installation of the more expensive heat recovery measures would generally only be introduced into a property that has undergone both the basic and intermediate measures recommendations. A property which has undergone such extensive works can be affected by a restricted air flow which may result in the property suffering from internal condensation. Design Considerations 1. Bath and shower use, Low Carbon Housing Retrofit b. Moisture and stale air from the activities within the home will also need to be removed both for comfort and for minimisation of allergens such as dust mites. With all the draughts removed this level of ventilation will need to be designed in. The greater the level of insulation the more the ventilation becomes a whole house solution. This can be done using passive stack ie’ (no fans) using the buoyancy of the warm air or by Mechanical Ventilation with Heat Recovery (MVHR) where a fan pushes the air thorough a heat recovery unit. Moisture in a home is produced principally by: 2. Cooking or 3. Drying clothes indoors or 4. Running an unvented tumble dryer. Residents may be tempted in these situations to open doors or windows to allow the moisture-laden air to escape, which will also cause the property to lose heat. It is recommended that the designer should consider the replacement of ordinary fans with the installation of new low voltage MVHR extractor fans within the kitchen and bathroom. Modern replacement fans have been developed to recover up to 85% of the heat loss during the extraction of the moist air from the room and at the same time bring in fresh air from the outside that is partially heated during the heat exchange process. An alternative would be a fully ducted ventilation system throughout the property either using a passive stack or with the unit located in the loft area that would allow the heat recovery to take place during the air exchange process. This option would be considerably more expensive. 27 Image by kind permission of Energy Saving Trust Designers of retrofit works will be aware that although the walls, roof and floor elements are the primary consideration when looking at energy efficiency, specific technical determinants such as eaves details, integral garages, extensions, rooms in the roof and velux windows will all need to be considered on a case by case basis. It is hoped that this document will allow retrofit designers and property owners to adopt a sensible and cost effective methodology for assessing the most appropriate measures to install and the most suitable order in which to undertake the work. 131263_City-South_Manchester_v5__ 19/03/2012 12:01 Page 28 28 Sustainability and the Home Low Carbon Housing Retrofit There is also a need to consider the effect of installing insulation to an existing wall structure when considering the general specification and performance calculations for the U-value. A before and after calculation to establish the dew point should be carried out by the designer to see if the insulation will cause any interstitial condensation within the existing materials. As noted above failure to do so could lead to mould growth, rot and fungi growth occurring within or on the structure behind the newly installed insulation material. The Retrofit Standards and Housing Intelligence Groups have taken the opportunity to set out the full range of measures which can be applied to provide a sustainable living environment. The list shown in Appendix A includes an extensive review of measures that can have a considerable impact on the following: • Energy Usage • Water Usage household’s energy consumption, financial expenditure and carbon footprint. Users are recommended to read the ‘Missing Quarter’ report which includes clear guidance on ensuring that behaviour change advice is included in any retrofit project or programme. It is commonly recognised that up to 25% of the annual cost of a typical home’s energy bill can be saved by adopting a different approach to energy use. Technology Advancement As with all advances in the field of energy efficiency the current range of products in the marketplace will have a varied impact on reaching the design standards required. Users need to be aware that, due to restrictions on available space within the home, it may not always be possible to incorporate some products. As the technology advances, and improvements are made to the products performance and overall size, such restrictions may be overcome. New products will continue to enter the market as the technology develops through increased innovation. It is anticipated that some of the older and harder to treat stock will be able to reach the 2050 target of an 80% reduction in their annual CO2 emissions, in a more cost effective and affordable way as a result of such innovations. This process will be streamlined at the Greater Manchester wide level by developing and using the stock intelligence database and web portal noted earlier. This will allow development and testing of new products, plus the effective dissemination and use of best practice information across the whole area. Summary This section will allow property owners and retrofit programme designers to assess their schemes against a range of specific issues which will affect all or some of the Greater Manchester housing stock. The topics above are not designed as a comprehensive list of issues but will provide a useful check list of specific considerations for any proposed works. • Behavioural Change • CO2 emissions. Individual users should consider that in future there will be ever increasing demands placed on both energy and water supplies. While the introduction of new technologies may help, it is recognised that changing our behaviour regarding how we use these scarce resources will make significant savings to a Image courtesy of C. Baker Image by kind permission of Energy Saving Trust 131263_City-South_Manchester_v5__ 19/03/2012 12:01 Page 29 4. Conclusions These will enable a Common Standard and Framework of retrofit measures to be adopted across all areas and organisations in Greater Manchester, yielding substantial financial savings and a pathway for achieving the national carbon emissions targets in the domestic housing retrofit sector. 1. With 1.1 million homes which are producing more than a third of the CO2 emissions in Greater Manchester, the developing Green Deal represents a significant opportunity for householders and landlords to improve the energy efficiency of their properties. This will contribute significantly towards the recently adopted Greater Manchester Climate Change Strategy target of 48% carbon emissions reduction by 2020, which exceeds the national target of 34%. 2. A review of the housing stock has identified 9 major archetypes of properties to aid understanding of what is required. 3. A potential for energy efficiency improvement for each archetype to reach the national carbon emissions reduction targets of 34% by 2020 and 80% by 2050, has been identified in the form of 12 a SAP rating linked to an Energy Performance Certificate and the associated amount of carbon per meter squared for that property type. 4. Each of these SAP target standards have then been analysed and a suite of energy efficiency measures designed appropriate to each archetype, identified as basic, intermediate (2020 target) and major interventions (2050 target). 5. A full evaluation of the cost and energy rating of each measure is included in the Technical Appendices. 6. Crucially information is also included indicating the most efficient and cost effective order in which to install these measures using natural trigger points within the lifespan of the property and it’s ownership. Examples of these trigger points would include such works as a new roof, new windows, kitchen/ bathroom upgrades or an extension. Lifestyle changes are also recognised as appropriate trigger points, including moving home, increased or reduced family size or occupancy. 7. It is recognised that property owners are unlikely to undertake a full retrofit of the property all at once; this document will help to ensure that an incremental ‘whole house’ approach is as efficient and cost effective as possible. 8. These levels of SAP/EPC/kg CO2 targets give property owners the option to upgrade the energy efficiency to the highest level possible during planned work to avoid potential wasteful and costly revisiting of the same areas later on when the higher levels are likely to be required. 9. A range of specific building considerations are discussed to ensure users of this document are informed of key issues that are important in any retrofit planning. 10. It is made clear that in order to reach these very stretching national targets for 2050 all the properties which already exist in Greater Manchester will require some form of retrofit to ensure they meet the energy efficiency standards required to achieve the 80% emissions savings. 11. Finally it is also acknowledged that some of the SAP/EPC/kg CO2 targets recommended will have to take advantage of newly developing technologies that may not be fully available yet. 12. Development of a Greater Manchester web portal and database of these archetypes and retrofit solutions could effectively be linked to the Building Research Establishment (BRE) National Refurbishment Centre12 and the National Energy Efficiency Data-Framework (NEED).13 www.rethinkingrefurbishment.com http://www.decc.gov.uk/assets/decc/11/stats/energy/energy-efficiency/2078-need-data-framework-report.pdf 13 Low Carbon Housing Retrofit The research and standards review carried out for this report has led to the following conclusions and recommendations. 29 131263_City-South_Manchester_v5__ 19/03/2012 12:01 Page 30 5. Recommendations Recommendations for this report were developed following the compilation of evidence by the GM Housing Retrofit Standards Group and the associated stakeholder seminar held in July 2010. The recommendations should be adopted to maximise the potential benefits of physical housing retrofit programmes and to endorse long term energy efficiency changes in behaviour. The following recommendations are made to inform those responsible for developing strategy and implementing domestic retrofit programmes in both the private and social sector. Sector Recommendation Social Landlords • That Social Landlords should take into consideration the recommended SAP/EPC/kg CO2 standards when developing, tendering or managing retrofit schemes. • That they should also take these standards into consideration when preparing future asset plans and maintenance budgets. • To link these standards and targets to planned maintenance ‘trigger points’ such as kitchen/bathroom upgrades or new windows etc, to ensure effective long term cost efficiencies. Low Carbon Housing Retrofit 30 • Take into consideration the items included in the specific considerations section when planning or tendering a project. Local Authorities • Local Authorities to recommend these SAP/EPC/kg CO2 standards to all social landlords, retrofit developers and private householders through the Planning and Building Control services. • To work with private landlords and Landlords Associations to promote the installation of measures to improve the energy efficiency for the private rented stock. This will include promotion through the landlords forums, the Greater Manchester Landlords Accreditation Scheme and where appropriate, active enforcement under the provision of the Housing Act 2004. • That householders be proactively made aware of these standards and opportunities for funding linked to the Green Deal/FITs/RHI etc when contact is made with the sustainability/housing or affordable warmth departments. Retrofit Developers • That developers, builders and designers include these standards in any retrofit schemes undertaken in Greater Manchester. • That the higher level standards are recommended to ensure effective long term cost efficiencies for the owners. • Be aware of the potential for linking Green Deal and other local and national funding to these standards. • Take into consideration the items included in the specific considerations section when planning or tendering a project. 131263_City-South_Manchester_v5__ 19/03/2012 12:01 Page 31 Recommendation Scheme Managers • To ensure that these standards are embedded in the project management and work plans. • To be aware of the potential for reaching the higher standards when retrofitting at a natural ‘trigger point’, rather than costly revisiting at a later date. Homeowners • To use this document to help plan the most efficient and effective energy efficient retrofit programme for their home, to ensure an incremental ‘whole house’ approach is used where possible. • That these standards are included in the contract documentation for any scheme or project. • Take into consideration the items included in the specific considerations section when planning or contracting a project. Low Carbon Housing Retrofit/LCEA committee • To carry out an annual review of this report in light of developments in retrofit technology and funding models such as the Green Deal. This will ensure that this document remains relevant and provides appropriate recommended standards up to 2020. Large scale Scheme Developers/ Installers • The Greater Manchester wide Toasty scheme should take flood risk factors into account prior to recommending specific materials for CWI. • To monitor the developments in domestic energy efficiency and retrofit technologies and encourage trial pilot schemes where appropriate. • To create the photo library of front elevations and develop the Greater Manchester Retrofit Housing Web Portal and Database to allow users to access the archetypes and measures packages as well as measuring progress towards the emissions reduction targets. Low Carbon Housing Retrofit Sector 31 131263_City-South_Manchester_v5__ 19/03/2012 12:01 Page 32 Greater Manchester Low Carbon Economic Area Retrofit Standards TECHNICAL APPENDICES Appendix A: Typical range of measures which can be utilised to enhance the properties sustainability and energy performance Green = Basic Measures Amber = Intermediate measures Purple = Major Measures Blue = Whole House Sustainable *Costs based on 2010 figures Sustainability and Energy Measures Low Carbon Housing Retrofit 32 Quantity Unit Rate* Cost* Undertake a before and after EPC certificate 2 No £60.00 £120.00 Air tightness test to establish leakage 2 item £60.00 £120.00 Draught stripping all doors and windows 100 m £1.30 £130.00 140 m2 £10.00 £1,400.00 Option A - Loft top up insulation to minimum 270mm laid between ceiling 0.16W/m2K rafters and on hatch to achieve set U-value 50 m2 £6.00 £380.00 Option B - loft top up insulation to 400mm, replace loft hatch 0.1W/m2K 50 m2 £10.00 £500.00 Cavity wall insulation 0.35W/m2k 80 m2 £4.00 £320.00 Option A - External wall insulation 0.35W/m2k 80 m2 £72.00 £5,760.00 Option B - external wall insulation - foam @approx 100mm, fibre 120mm 0.25W/m2/K 80 m2 £86.00 £6880.00 Option C - external wall insulation - foam @approx 175mm, fibre 220mm 0.15W/m2/K 80 m2 £100.00 £8000.00 Provide 100% low energy light bulbs fitted internally and externally 10 No £5.00 £50.00 Lay hardboard covering over floor boards to prevent air leakage Aim 6mm thick Option A – Internal insulation - Dry lining of all external walls to achieve minimum U-value 0.35W/m2k 80 m2 £45.00 £3,600.00 Option B – Internal insulation - Dry lining of all external walls to achieve intermediate U-value 0.25W/m2k 80 m2 £65.00 £5,200.00 Option A - Install double glazed PVCu windows 1.7W/m2k 9 No £350.00 £3,150.00 Option B - Install double glazed gas filled PVCu windows 1.5W/m2k 9 No £ 375.00 £3,375.00 Option C - Install triple glazed PVCu windows 0.9W/m2k 9 No £420.00 £3,780.00 Option D - Install composite frame triple glazed windows 0.7W/m2K 9 No £550.00 £4,950.00 Option A - Install new insulated PVCu doors (Solid / 50% glazed doors) 1.7W/m2k 2 No £550.00 £1,100.00 Option B - Install new insulated PVCu doors (Solid / 25% glazed doors) 1.0W/m2k 2 No £650.00 £1,300.00 Option A - Overlay existing ground floor with 25mm insulated boarding 10mm thick 70 m2 £12.00 £840.00 131263_City-South_Manchester_v5__ 19/03/2012 12:01 Page 33 Sustainability and Energy Measures Aim Rate* Cost* 70 m2 £35.00 £2,450.00 20 m £70.00 £1,400.00 20 m £65.00 £1,300.00 Install Smart meter data display for monitoring energy usage 1 No £65.00 £65.00 Voltage optimisation install a Voltage optimisation meter 1 No £ 400.00 £400.00 Upgrade heating controls including new thermostat programmer in line with CHeSS (2005) 1 item £120.00 £120.00 Thermostatic radiator valves fitted to all radiators 7 No £ 25.00 £175.00 Install A rated condensing boiler fitted with low levels of NOx 1 No £1,800.00 £1,800.00 Option B - Take up ground floor boards and insulate between joists and relay to achieve 0.7 U-value Option C - Dig out trench around external walls and put in recycled foamed glass pumice insulation (Misapor) to achieve 0.45W/m2/K U-value Option D - Take up ground floor boards as option B and insulate trench around external walls as option B to achieve 0.25W/m2/K U-value Aerated showerhead flow restrictor to reduce flow rate 8 ltr/min 1 item £15.00 £15.00 Alternative to electric shower, install thermostatic mixer taps which can control shower temperature fed direct from combi boiler. Remove scalding potential 1 item £345.00 £345.00 3 No £85.00 £255.00 2 No £170.00 £340.00 1 item £1,350.00 £1,350.00 1 Item £3,500.00 £3,500.00 2No 1 item £4,300.00 £4,300.00 4No 1 item £7,150.00 £7,150.00 1.1KWp 1 item £4,500.00 £4,500.00 2.1KWp 1 item £5,200.00 £5,200.00 3.9KWp 1 item £6,500.00 £6,500.00 Install Electric shower 8.5kW 1 item £145.00 £145.00 Fit new bath sized 156ltr 1 item £275.00 £ 275.00 Duel flush WC cisterns 4/2 ltr 2 No £65.00 £130.00 Target water usage to meet the set levels of 115 ltr per person per day Goal 1 item £20.00 £20.00 Water butt for non potable water 200ltr 1 item £225.00 £225.00 Recycling water for WC cistern usage 100ltr 1 item £195.00 £195.00 Monitor water rate flow before and after 2 item £45.00 £90.00 External clothes rotary dryer fitted 1 No £65.00 £65.00 Composting bin supplied 1 No £75.00 £75.00 1 item £320.00 £320.00 1 item £20.00 £20.00 Spray taps and flow regulators provided for wash hand basins and kitchen 8 ltr /min sink SAP Appendix Q extractor fans fitted whole house including bathroom and kitchen Install heat recovery system by installing ventilation within house and system in loft Option A - Install 2 panel solar thermal system and 215 ltr indirect twin 2No coil cylinder to existing heating system to provide hot water Option B - Install 2 x 20 evacuated tube solar thermal system as above Option C - install 4 x 20 tube evacuated tubes and twin coil solar thermal store Option A - Solar photovoltaic panel to provide electricity for lights and appliances Option B - Solar photovoltaic panel to provide electricity for lights and appliances Option C - Solar photovoltaic panel to provide electricity for lights and appliances Waste storage and recycling area as defined by BS 5906 General sustainable homes guide and operational manual 3No bins Low Carbon Housing Retrofit Quantity Unit 33 131263_City-South_Manchester_v5__ 19/03/2012 12:01 Page 34 TECHNICAL APPENDICES Wall U-values and Improvements Based on Applied Insulation Measures – Appendix B Walls are particularly complex when considered for energy efficiency improvements, with a number of different common wall construction designs, and several treatments that can be applied to improve the thermal efficiency. To assist in demonstrating the effectiveness of the these various treatments, the following illustrations have been provided as a guide to the typical U-values that may be obtained for differing types of wall construction, from the ‘as built’ construction. This level of detail has not been included for other property elements such as roofs and floors as these have a much smaller range of retrofit options. 1 Low Carbon Housing Retrofit 34 • Cavity wall construction referred to in archetypes 5 to 8 is covered by Type “D” to “E” treatments. • Solid wall treatment referred to in Type “F” would be applicable in system built properties referred to in archetype 9. 2 Wall construction Inside • The solid wall construction referred to in archetypes 1 to 4 is covered in Type “A” to “C” treatments. existingW/ m2K-1 3 1st visit (basic or interim) Outside 215mm solid wall 2.03 IWI part 215mm solid wall porous brickwork 2.03 IWI part 340mm solid wall Produced in partnership with Urbed 1.30 0.36 0.37 IWI part 0.33 target 0.15W/m2K-1 forecast U-value W/m2K-1 add rendered 30mm phenolic foam bonded to 30mm aerogel fixed to wall with plastic pin fixings EWI to finish 0.16 add external polymer render on 160mm woodfibre insulation fixed direct to external wall EWI to finish 0.16 add polymer modified render on 120mm mineral wool on external face fixed with plastic pin fixings plastered 55mm phenolic foam on base coat on internal face 25mm plaster, on brick + half wall C 2nd visit internal smooth coat polymer render vapour control layer on 100mm woodfibre 25mm plaster, on 215mm brick wall B forecast U-value W/m2K-1 fermacel board fixed to internal wall through 30mm aerogel insulation 25mm plaster, on 215mm brick wall A target 0.35W/m2K-1 EWI to finish 0.16 131263_City-South_Manchester_v5__ 19/03/2012 12:01 Page 35 will have to be repaid back from the savings achieved through the ongoing energy bill. There are a substantial range of products available which could equal or better the performance of the products used in these calculations. When undertaking a formal technical assessment the designer should make their recommendations based on the products offering the highest achievable performance and value for money to the end user. The designer will have to bear in mind that the cost of the works to be undertaken single visit external 5 target 0.2W/m2K-1 forecast U-value W/m2K-1 single visit target internal 0.25W/m2K-1 rendered 50mm phenolic foam bonded to 30mm aerogel fixed to wall with plastic pin fixings full EWI 0.20 fermacel board fixed to internal wall through 50mm aerogel insulation full IWI external polymer render on 180mm woodfibre insulation fixed direct to external wall full EWI 0.20 full IWI 0.20 Where there are issues as above and such as with lime mortar and porous bricks a vapour permeable insulant should be used. Wood fibre also has wicking properties as well as carbon sequestration and renewable advantages but it is costly. 0.26 plastered 80mm phenolic foam on base coat on internal face full IWI These measures suit a wall with feature internal plaster or limited space so an insulant at or near the thickness of the existing plaster is required internally. Further advice should be sought before using a non permeable external insulant on old buildings eg. if there is timber within the construction of the wall. 0.26 internal smooth coat polymer render vapour control layer on 150mm woodfibre polymer modified render on 160mm mineral wool fixed to external face with plastic pin fixings full EWI forecast U-value W/m2K-1 The specifications here are not the only solutions, only suggestions for some scenarios. These are described briefly here as an aid. 0.25 Phenolic foam can be used internally as it is much less toxic in a fire. Mineral wool offers vapour permeability at a lower cost but without other advantages. There are technical issues with it self-supporting at high thicknesses. Low Carbon Housing Retrofit 4 Designers should consider the insulations materials available and assess the performance criteria in use. There are various manufactured products available that will meet all the possible design criteria requirements along with more natural and sustainable products such as sheep’s wool etc. 35 131263_City-South_Manchester_v5__ 19/03/2012 12:01 Page 36 TECHNICAL APPENDICES Appendix B (continued) 1 2 Wall construction Inside existingW/ m2K-1 3 1st visit (basic or interim) Outside 250mm small cavity wall 1.37 IWI part Low Carbon Housing Retrofit 36 275mm cavity wall 1.39 cavity fill non-trad 2.58 0.79 0.51 EWI part 0.37 target 0.15W/m2K-1 forecast U-value W/m2K-1 add external polymer render on 220mm woodfibre insulation fixed direct to external wall EWI to finish 0.16 add polymer modified render on 105mm phenolic foam on base coat on external face EWI to finish polymer modified render on 100mm mineral wool external insulation 20mm render on 200mm wimpey no-fines with 15mm plaster F 2nd visit injected cavity fill, graphite coated polystyrene bead achieves 0.49 W/m2K 15mm plaster, 2 standard brick courses, 50mm cavity E forecast U-value W/m2K-1 injected cavity fill, graphite coated polystyrene bead achieves 0.79 W/m2K 20mm plaster, 2 standard brick courses, 25mm cavity D target 0.35W/m2K-1 0.15 add plastered 85mm phenolic foam on base coat on internal face IWI to finish 0.15 131263_City-South_Manchester_v5__ 19/03/2012 12:01 Page 37 4 single visit external 5 target 0.2W/m2K-1 forecast U-value W/m2K-1 single visit target internal 0.25W/m2K-1 full EWI 0.19 full IWI polymer modified render on 100mm phenolic foam on base coat on external face full EWI 0.20 0.21 There may be little advantage to insulating cavities this small and going straight to the external wall insulation. Where there are issues with moisture in a property, wicking permeable external insulants will assist in creating a better internal environment as well as insulating the property. 0.26 plastered 75mm phenolic foam on base coat on internal face full IWI full IWI 37 Where there is a big enough cavity for any moisture condensing in the cavity to run to ground and also so there is clear separation between internal and external leaf, phenolic foam is a cost effective insulation method due to its low thermal conductivity. 0.26 fermacel board on battens with 20mm rubber coated Vacuum insulated panels between on levelling basecoat rain-screen cladding on proprietary support rails with 200mm mineral wool insulation between full EWI internal smooth coat polymer render vapour control layer on 140mm woodfibre 0.26 Low Carbon Housing Retrofit external polymer render on 180mm woodfibre insulation fixed direct to external wall forecast U-value W/m2K-1 The specifications here are not the only solutions, only suggestions for some scenarios. These are described briefly here as an aid. The assumption here is that in non trad properties movement and cracking mean that it is inadvisable to put vapour impermeable insulants on the outside of the property however as vapour pressure is almost always outward foams are suggested here. 131263_City-South_Manchester_v5__ 19/03/2012 12:01 Page 38 TECHNICAL APPENDICES Appendix C: References & Sources 1. Department for Energy and Climate Change: http://www.decc.gov.uk/ 2. Energy Saving Trust: http://www.energysavingtrust.org.uk/ 3. Building Research Establishment: http://www.bre.co.uk/ 4. Greater Manchester Climate Change Strategy: http://www.agma.gov.uk/cms_media/files /gm_climate_change_strategy_final1.pdf Low Carbon Housing Retrofit 38 5. The Building Regulations Part L1B, October 2010. http://www.legislation.gov.uk/uksi/2010/2 214/contents/made 6. Sustainable refurbishment CE 309, Energy Saving Trust. http://www.energysavingtrust.org.uk/ business/Business/Housingprofessionals/ Existing-housing/Housetypes 7. Detailed House type scenarios including EPC/CO2 and financial savings for 8 principle archetypes: http://www.energysavingtrust.org.uk/ Publication-Download/?oid=1532044&cg =bestpracticedocs&ci=energyst 8. Moving Beyond the Decent Homes Standard 2009, Sustainable Housing Action Partnership. http://www.shap.uk.com/ 9. Greener Homes for Redbridge, Property portfolio. http://www.east-homes.co.uk/ CMSPage.aspx?ssbid=2987 10. Domestic low and zero carbon technologies: CE 317, Energy Saving Trust: http://www.energysavingtrust.org.uk/busi ness/Global-Data/Publications/CE-317Domestic-low-and-zero-carbontechnologies 11. Energy Saving Trust publications including: Materials Chart: CE71 http://www.energysavingtrust.org.uk/busi ness/Business/Housingprofessionals/Publications-and-casestudies 12. National Refurbishment Centre and Portal: http://www.rethinkingrefurbishment.com/ 13. Old Homes Super Homes: http://superhome.urbed.coop/ 14. Retrofit for the Future: http://retrofitforthefuture.org/viewproject. php?id=186 15. Isothane Ltd http://www.isothane.com/ 16. Vent Axia Ltd http://www.vent-axia.com/ Interstitial and surface condensation references 17. British Standard 5250: Code of Practice for Control of Condensation in Buildings, 2002 and revisions, BSI. 18. Garratt, J and Nowak, F, Tackling condensation, BRE Report 174 (BR 174), Building Research Establishment, Watford, 1991. 19. The Building Regulations Part F, October 2010 131263_City-South_Manchester_v5__ 19/03/2012 12:01 Page 39 KW Kilo Watts Glossary of Terms KWh Kilo Watt Hours AGMA LSOA Local Super Output Areas MCC Manchester City Council mm millimetres MVHR Mechanical Ventilation and Heat Recovery National Home Energy Rating Association of Greater Manchester Authorities BRE Building Research Establishment BS British Standard CERT Carbon Emission Reduction Target CESP Community Energy Saving Programme NHER CHP Combined Heat and Power CO2 Carbon Dioxide OFGem Office of the Gas and Electricity Markets CWI Cavity Wall Insulation DEA PUR Polyurethane Foam Domestic Energy Assessor PVCu Polyvinyl Chloride Un-plasticised DECC Department of Energy and Climate Change PV Photovoltaic ECO Energy Company Obligation RHI Renewable Heat Incentive ELENA European Local Energy Assistance EPC Energy Performance Certificate EPS Expanding Polystyrene ERDF European Regional Development Fund EST Energy Saving Trust FiTs Feed-in Tariffs GM Greater Manchester RDSAP Reduced Data Standard Assessment Procedure SAP Standard Assessment Procedures SWI Solid Wall Insulation TRV Thermostatic Radiator Valve U-Value Measure of thermal efficiency of a building element Low Carbon Housing Retrofit Appendix D: Glossary of terms 39 131263_City-South_Manchester_v5__ 19/03/2012 12:01 Page 40 Low Carbon Housing Retrofit Greater Manchester Published by City South Manchester Housing Trust for the Retrofit Standards Group Printed by ERDF NW, Northwards Housing, Salford University and Wigan and Leigh Housing for the Retrofit Standards Group
© Copyright 2026 Paperzz