Dosing System Manual Customer Technical Service - Engineering Installation, Commissioning and Technical Information for the 5 - 75 L/Hr Marine Dosing Unit Innospec Limited PO Box 17 Oil Sites Road Ellesmere Port Cheshire CH65 4EY, U.K. tel: +44 (0)151 355 3611 fax: +44 (0)151 356 2349 The information contained in this document is provided free of charge and is based on technical data that Innospec believes to be reliable. It is intended for use by persons having technical skill and at their own discretion and risk. Innospec accepts no liability for any loss, damage or expense arising from, or in connection with, the use of the information. Furthermore, none of the contents of this publication should be taken as a licence to operate under any patent, nor as a recommendation to infringe any patent. 5-75 L/Hr Dosing Unit Issue No 1 May 2007 Dosing System Manual Contents Description Page No. System Specifications 3 Functional Description 3 General Layout Drawing 4 Equipment Overview Drawing 5 Parts Listing 6 Electrical Wiring Drawings 7 Injector Layout Drawing 8 Installation Procedure 9 - 10 Commissioning Procedure 10 - 11 Spare Parts 11 Technical Information and dosing graphs 12 5-75 L/Hr Dosing Unit Page 2 of 12 Issue 1 May 2007 Dosing System Manual System Specifications Unit Dimensions : 500 (H) x 400 (W) x 300 (D) (mm) Packaged Dimensions: 600 (H) x 500 (W) x 400 (D) (mm) Packaged Weight : ~ 42 Kg’s Power Supply : 115 – 230 – 400 – 440 VAC 50/60 Hz Nom. Back Pressure: 2.0 Barg Maximum Back Pressure : 4.0 Barg at 50 Hz; 3.5 Barg at 60 Hz Functional Description The INNOSPEC Marine dosing system is designed to dose into the ship’s main bunkerline. The system should be switched ON at start bunkering and switched OFF at end of bunkering of fuel oil. As an alternative the system can dose into the suction filter of the transferpump, for automatic Start/Stop an optional External Start/Stop cabinet has to be installed. To test the dosing pump or to bleed the system, see under part commissioning (page 10 – 11). ALWAYS ENSURE THAT THE CORRECT VOLTAGE IS CONNECTED! Power Supply: 115 – 230 – 400 – 440 VAC; 50/60 Hz. The selection switch (12) on switch cabinet (11) has to be set accordingly. 5-75 L/Hr Dosing Unit Page 3 of 12 Issue 1 May 2007 Dosing System Manual General Lay-Out Drawing 5-75 L/Hr Dosing Unit Page 4 of 12 Issue 1 May 2007 Dosing System Manual Equipment Overview 5-75 L/Hr Dosing Unit Page 5 of 12 Issue 1 May 2007 Dosing System Manual Equipment List ITEM QTY DESCRIPTION 1 1 Dosing pump DMX 75-4 221-75-10198 GRU-DMX75-4PVT 2 1 Flow counter VZO 8 VIT-9263000 3 1 Bleed valve Ball valve 8 mm ALA-74500808 4 1 Check valve spring loaded Check valve 10 mm; 1 barg SO-47321-10-1 bar 5 1 Injector with check valve assembly AQ-10700200 + SO-7300-1/2”-1 bar 6-7 1 Suction assembly AQ-10700XXX 8 1 Drum closer + Quick connector Injector 1/2"x1/2" Check valve 1/2"; 1 barg HYD-1271983-100+TEE21042300+AQ-10700185 AQ-10700111+GEH940206+GEH-940106VIT 9 1 Drum Breather Breather 3/4" AQ-10700070 10 1 Main switch in box Main switch 3 Phase 20 Amp Ye/Rd SOL-5960892 11 1 Switch cabinet incl. transformer CI2216A + WEC-30000020 AQ-1070XXXX 12 1 Selection switch M220 61070 219M1 SOL-5960170 5-75 L/Hr Dosing Unit Page 6 of 12 TYPE ARTICLE CODE AQ-107000XX Issue 1 May 2007 Dosing System Manual Electrical Wiring Drawings 5-75 L/Hr Dosing Unit Page 7 of 12 Issue 1 May 2007 Dosing System Manual Injector Layout Drawing 5-75 L/Hr Dosing Unit Page 8 of 12 Issue 1 May 2007 Dosing System Manual Installation Procedure Securely mount the dosing cabinet, using the fixing brackets supplied, to a suitable location in the vicinity of the fuel transfer pumps. Ensure that the Octamar™ product drum is secured tightly to the ship build so free movement is not possible. SECURE THE OCTAMAR™ PRODUCT DRUM Assemble the suction, bleed and discharge hoses using the components as shown in the Equipment Overview (page 5). 5-75 L/Hr Dosing Unit Page 9 of 12 Issue 1 May 2007 Dosing System Manual A. Connect the pump suction side with flexible hose to the suction assembly and drum closer with suction filter (6, 7, 8). Note: The suction hose should be kept as short as possible (2 metres). B. Mount the suction hose with suction assembly, drum-closer and suction filter to the product drum. Note: Ensure that the drum-closer is screwed in completely so that the suction valve and filter will hang 1 cm above the bottom of the drum. Important: The vertical distance (height) between pump unit and bottom of the product drum must not exceed 2 meters (6,5 feet). C. Connect the pump discharges with flexible hoses to the injection assembly and fit the injection nozzle in the main bunkerline. D. Connect the short air bleed hose and place a small container beneath the outlet from the bleed discharge. E. Connect a power supply cable to main switch in box (10). The power supply is 2 phases 115 or 230 or 400 or 440 VAC 50/60 Hz. The power supply is connected directly to the main switch at terminal 1 and 3 and Earth (PE). F. Before powering up the system check if the selection switch (12) is set at right voltage level. Commissioning Procedure The INNOSPEC Marine dosing system is designed to dose into the ship’s main bunkerline. The system should be switched ON at start bunkering and switched OFF at end of bunkering of fuel oil. As an alternative the system can dose into the suction filter of the transferpump, for automatic Start/Stop an optional External Start/Stop cabinet has to be installed. Prior to putting the dosage unit into service, the system has to be primed and bled of air. After priming of the unit is completed, setting of the correct chemical dosage rate (flow rate in L/hr) will also be required. You will be informed of the recommended flow rate for your installation prior to commissioning. Please follow the instructions below. A. Make sure all connections are tight. B. Make sure the dosing system is switched ON at main switch (10). C. Make sure the stroke length of the dosage pump is set at 100%. This is the large knob on the pump console. Unscrew the locking screw before turnig the knob. D. Open the air bleed valve (3) 5-75 L/Hr Dosing Unit Page 10 of 12 Issue 1 May 2007 Dosing System Manual E. After a few minutes, chemical will discharge from the air bleed hose. F. When there is a constant flow of chemical from the air bleed hose, shut air bleed valve (3). G. Adjust the flow rate with the large knob on the pump. See dosing graph on page 12. The knob can be set from 0 – 100 % and is locked tight using a locking screw. Loosen this screw before altering the setting. Tighten the screw after setting of the desired flowrate. The flow rate can be checked with the flow counter (2). H. Switch OFF the power to the dosage unit and close the panel door. Note: Re-priming of the pump may be necessary after changing the product drum and/or if the pump and hoses are disconnected for maintenance or repair. Spare Parts If spare parts are required, please contact your nearest Innospec Marine Specialties office. Address and contact details are on the inside of the cabinet door. Please quote the pump serial number, the system serial number and item(s) you require. Please also refer to the parts listing shown in the Equipment Overview Drawing and Parts Listing on page 5 - 6 of this manual. USA Europe, Middle East, Africa Innospec – Marine Specialties Customer Service Centre - USA 8375 South Willow Street Littleton, CO 80124 USA Tel: +1 800 441 9547 Fax: +1 303 792 5668 e-mail: [email protected] Innospec – Marine Specialties Customer Service Centre - EMEA P.O. Box 53156 CY-3301 Limassol Cyprus Tel: +357 25 762 535 Fax: +357 25 762 545 e-mail: [email protected] Greece/Turkey Asia Pacific Innospec Hellas Ltd. Marine Specialties Customer Service Centre - Greece & Turkey 11, II Merarchias Street 185-35 Piraeus Greece Tel: +30 210 411 0727 / 8 Fax: +30 210 411 0748 e-mail: [email protected] Innospec – Marine Specialties Customer Service Centre - Asia Pacific 47 Scotts Road, #02-03 Goldbell Towers Singapore 228233 Tel : +65 6336 6286 Fax : +65 6336 1692 e-mail: [email protected] 5-75 L/Hr Dosing Unit Page 11 of 12 Issue 1 May 2007 Dosing System Manual TECHNICAL INFORMATION Grundfos Alldos Primus 221 75-4 Motor Driven Dosing Pump Note: The pump has been calibrated to operate between 5-75 litres per hour. The Grundfos Alldos manual is attached for reference. 5-75 L/Hr Dosing Unit Page 12 of 12 Issue 1 May 2007
© Copyright 2026 Paperzz