Dosing System Manual

Dosing System Manual
Customer Technical Service - Engineering
Installation, Commissioning
and Technical Information
for the 5 - 75 L/Hr
Marine Dosing Unit
Innospec Limited
PO Box 17
Oil Sites Road
Ellesmere Port
Cheshire CH65 4EY, U.K.
tel: +44 (0)151 355 3611
fax: +44 (0)151 356 2349
The information contained in this document is provided free of charge and is based on technical data that Innospec believes to be reliable. It is intended
for use by persons having technical skill and at their own discretion and risk. Innospec accepts no liability for any loss, damage or expense arising from, or
in connection with, the use of the information. Furthermore, none of the contents of this publication should be taken as a licence to operate under any
patent, nor as a recommendation to infringe any patent.
5-75 L/Hr Dosing Unit
Issue No 1 May 2007
Dosing System Manual
Contents
Description
Page No.
System Specifications
3
Functional Description
3
General Layout Drawing
4
Equipment Overview Drawing
5
Parts Listing
6
Electrical Wiring Drawings
7
Injector Layout Drawing
8
Installation Procedure
9 - 10
Commissioning Procedure
10 - 11
Spare Parts
11
Technical Information and dosing graphs
12
5-75 L/Hr Dosing Unit
Page 2 of 12
Issue 1 May 2007
Dosing System Manual
System Specifications
Unit Dimensions :
500 (H) x 400 (W) x 300 (D) (mm)
Packaged Dimensions:
600 (H) x 500 (W) x 400 (D) (mm)
Packaged Weight :
~ 42 Kg’s
Power Supply :
115 – 230 – 400 – 440 VAC 50/60 Hz
Nom. Back Pressure:
2.0 Barg
Maximum Back Pressure : 4.0 Barg at 50 Hz; 3.5 Barg at 60 Hz
Functional Description
The INNOSPEC Marine dosing system is designed to dose into the ship’s main bunkerline. The system
should be switched ON at start bunkering and switched OFF at end of bunkering of fuel oil.
As an alternative the system can dose into the suction filter of the transferpump, for automatic
Start/Stop an optional External Start/Stop cabinet has to be installed.
To test the dosing pump or to bleed the system, see under part commissioning (page 10 – 11).
ALWAYS ENSURE THAT THE CORRECT VOLTAGE IS CONNECTED!
Power Supply:
115 – 230 – 400 – 440 VAC; 50/60 Hz.
The selection switch (12) on switch cabinet (11) has to be set accordingly.
5-75 L/Hr Dosing Unit
Page 3 of 12
Issue 1 May 2007
Dosing System Manual
General Lay-Out Drawing
5-75 L/Hr Dosing Unit
Page 4 of 12
Issue 1 May 2007
Dosing System Manual
Equipment Overview
5-75 L/Hr Dosing Unit
Page 5 of 12
Issue 1 May 2007
Dosing System Manual
Equipment List
ITEM
QTY
DESCRIPTION
1
1
Dosing pump DMX 75-4
221-75-10198
GRU-DMX75-4PVT
2
1
Flow counter
VZO 8
VIT-9263000
3
1
Bleed valve
Ball valve 8 mm
ALA-74500808
4
1
Check valve spring loaded
Check valve 10 mm; 1 barg
SO-47321-10-1 bar
5
1
Injector with check valve assembly
AQ-10700200 +
SO-7300-1/2”-1 bar
6-7
1
Suction assembly
AQ-10700XXX
8
1
Drum closer + Quick connector
Injector 1/2"x1/2" Check
valve 1/2"; 1 barg
HYD-1271983-100+TEE21042300+AQ-10700185
AQ-10700111+GEH940206+GEH-940106VIT
9
1
Drum Breather
Breather 3/4"
AQ-10700070
10
1
Main switch in box
Main switch 3 Phase 20
Amp Ye/Rd
SOL-5960892
11
1
Switch cabinet incl. transformer
CI2216A + WEC-30000020
AQ-1070XXXX
12
1
Selection switch
M220 61070 219M1
SOL-5960170
5-75 L/Hr Dosing Unit
Page 6 of 12
TYPE
ARTICLE CODE
AQ-107000XX
Issue 1 May 2007
Dosing System Manual
Electrical Wiring Drawings
5-75 L/Hr Dosing Unit
Page 7 of 12
Issue 1 May 2007
Dosing System Manual
Injector Layout Drawing
5-75 L/Hr Dosing Unit
Page 8 of 12
Issue 1 May 2007
Dosing System Manual
Installation Procedure
Securely mount the dosing cabinet, using the fixing brackets supplied, to a suitable location in the vicinity of the
fuel transfer pumps.
Ensure that the Octamar™ product drum is secured tightly to the ship build so free movement is
not possible.
SECURE
THE
OCTAMAR™
PRODUCT
DRUM
Assemble the suction, bleed and discharge hoses using the components as shown in the Equipment
Overview (page 5).
5-75 L/Hr Dosing Unit
Page 9 of 12
Issue 1 May 2007
Dosing System Manual
A.
Connect the pump suction side with flexible hose to the suction assembly and drum closer with
suction filter (6, 7, 8).
Note: The suction hose should be kept as short as possible (2 metres).
B. Mount the suction hose with suction assembly, drum-closer and suction filter to the product drum.
Note: Ensure that the drum-closer is screwed in completely so that the suction valve and filter will
hang 1 cm above the bottom of the drum.
Important: The vertical distance (height) between pump unit and bottom of the product drum must
not exceed 2 meters (6,5 feet).
C. Connect the pump discharges with flexible hoses to the injection assembly and fit the injection nozzle in the
main bunkerline.
D. Connect the short air bleed hose and place a small container beneath the outlet from the bleed discharge.
E. Connect a power supply cable to main switch in box (10). The power supply is 2 phases 115 or 230 or 400
or 440 VAC 50/60 Hz. The power supply is connected directly to the main switch at terminal 1 and 3 and
Earth (PE).
F. Before powering up the system check if the selection switch (12) is set at right voltage level.
Commissioning Procedure
The INNOSPEC Marine dosing system is designed to dose into the ship’s main bunkerline. The system
should be switched ON at start bunkering and switched OFF at end of bunkering of fuel oil.
As an alternative the system can dose into the suction filter of the transferpump, for automatic
Start/Stop an optional External Start/Stop cabinet has to be installed.
Prior to putting the dosage unit into service, the system has to be primed and bled of air. After priming
of the unit is completed, setting of the correct chemical dosage rate (flow rate in L/hr) will also be required. You
will be informed of the recommended flow rate for your installation prior to commissioning.
Please follow the instructions below.
A. Make sure all connections are tight.
B. Make sure the dosing system is switched ON at main switch (10).
C. Make sure the stroke length of the dosage pump is set at 100%. This is the large knob on the pump
console. Unscrew the locking screw before turnig the knob.
D. Open the air bleed valve (3)
5-75 L/Hr Dosing Unit
Page 10 of 12
Issue 1 May 2007
Dosing System Manual
E. After a few minutes, chemical will discharge from the air bleed hose.
F. When there is a constant flow of chemical from the air bleed hose, shut air bleed valve (3).
G. Adjust the flow rate with the large knob on the pump. See dosing graph on page 12. The knob can be set
from 0 – 100 % and is locked tight using a locking screw. Loosen this screw before altering the setting.
Tighten the screw after setting of the desired flowrate. The flow rate can be checked with the flow counter
(2).
H. Switch OFF the power to the dosage unit and close the panel door.
Note: Re-priming of the pump may be necessary after changing the product drum and/or if the pump and hoses
are disconnected for maintenance or repair.
Spare Parts
If spare parts are required, please contact your nearest Innospec Marine Specialties office. Address
and contact details are on the inside of the cabinet door.
Please quote the pump serial number, the system serial number and item(s) you require. Please also
refer to the parts listing shown in the Equipment Overview Drawing and Parts Listing on page 5 - 6 of this
manual.
USA
Europe, Middle East, Africa
Innospec – Marine Specialties
Customer Service Centre - USA
8375 South Willow Street
Littleton, CO 80124
USA
Tel: +1 800 441 9547
Fax: +1 303 792 5668
e-mail: [email protected]
Innospec – Marine Specialties
Customer Service Centre - EMEA
P.O. Box 53156
CY-3301 Limassol
Cyprus
Tel: +357 25 762 535
Fax: +357 25 762 545
e-mail: [email protected]
Greece/Turkey
Asia Pacific
Innospec Hellas Ltd.
Marine Specialties
Customer Service Centre - Greece & Turkey
11, II Merarchias Street
185-35 Piraeus
Greece
Tel: +30 210 411 0727 / 8
Fax: +30 210 411 0748
e-mail: [email protected]
Innospec – Marine Specialties
Customer Service Centre - Asia Pacific
47 Scotts Road, #02-03 Goldbell Towers
Singapore 228233
Tel : +65 6336 6286
Fax : +65 6336 1692
e-mail: [email protected]
5-75 L/Hr Dosing Unit
Page 11 of 12
Issue 1 May 2007
Dosing System Manual
TECHNICAL INFORMATION
Grundfos Alldos Primus 221 75-4 Motor Driven Dosing Pump
Note: The pump has been calibrated to operate between 5-75 litres per hour.
The Grundfos Alldos manual is attached for reference.
5-75 L/Hr Dosing Unit
Page 12 of 12
Issue 1 May 2007