Product Data Sheet Version 02 (01 / 2010) Sika® Glazing Tape Prefix Glazing tape for glass pre-fixation Technical Product Data Closed-cell polyethylene foam carrier with acrylic adhesive on both sides and siliconised paper or filmic liner 0.1 mm Black / White 1.5 mm 6, 8, 10, 12 mm 15 - 50°C (60 - 120°F) 2 0.35 N/mm approx. 2 0.28 N/mm approx. 2 1.4 N/mm approx. 250 % approx. 2 0.1 N/mm -40 - 70°C (-40 - 160°F) 15 - 25°C (60 - 75°F) 12 months Liner thickness Colour 3) Total thickness including liner Available widths (other widths upon request) Application temperature 2 Tensile strength on glass (DIN 52 455) 2 Tensile shear strength on glass (DIN 52 455) 1 Tensile strength of foam (CQP 036-1 / ISO 37) 1 Elongation at break of foam (CQP 036-1 / ISO 37) Compression force (DIN 53 577) 1 Service temperature (CQP 513-1) Storage Shelf life 1) CQP = Corporate Quality Procedure Description ® Sika Glazing Tape Prefix is a high performance double-coated pressure sensitive foam tape used to attach glass, PVC, wood, metal or painted surfaces with minor pretreatment. ® Sika Glazing Tape Prefix is manufactured in accordance with ISO 9001 / 14001 quality assurance system and the responsible care program. 2) 23°C (73°F) / 50% r.h. 3) Product Benefits - Excellent UV-Resistance - Excellent humidity resistance - Excellent solvent resistance - Excellent adhesion to most surfaces with minor pre-treatment - High initial tack - Easy release liner other thicknesses upon request Areas of Application ® Sika Glazing Tape Prefix is used where immediate handling and transportation of assembled parts is required. Typical area of application is the attachment of glass to sash frame in windows. ® Sika Glazing Tape Prefix is used for non-structural purposes only. This product is suitable for professional experienced users only. Tests with actual substrates and conditions have to be performed to ensure adhesion and material compatibility. Sika® Glazing Tape Prefix 1 / 2 Chemical base Application The tape must be oriented and positioned on the first surface (e.g. sash frame) with liner on and then firmly pressed down. The protective liner shall be deducted immediately before the second surface is attached (e.g. glass or insulating glass, previously cleaned, see above). It must be ensured that the tape has full contact with the respective substrate surface. Minimal pressure evenly applied on whole bond surface shall be applied in order to assure optimal adhesion. Once affixed, the tape shall not be removed or repositioned. It is therefore important that the tape is immediately correctly positioned. If the component is positioned incorrectly, the tape shall be removed and disposed. The assembling shall be repeated with new material after bond faces are cleaned. ® Sika Glazing Tape Prefix is compatible with Sikasil SG, WT, WS and IG sealants and adhesives. Other sealants must be compatible, tested and approved by Sika before using them in ® combination with Sika Glazing Tape Prefix. The tape is suitable for manual and automated application. For advice on selecting and setting up a suitable application system please contact the System Engineering Department of Sika Industry. Removal ® Sika Glazing Tape Prefix may be removed mechanically. Further Information Copies of the following publications are available on request: - Material Safety Data Sheets Packaging Information Logs 50 m Cross Coil Max. 1200 m Value Bases All technical data stated in this Product Data Sheet are based on laboratory tests. Actual measured data may vary due to circumstances beyond our control. Further information available at: www.sika.ch www.sika.com Sika Schweiz AG Business Unit Industry Tüffenwies 16 CH-8048 Zurich Switzerland Tel. +41 58 436 40 40 Fax +41 58 436 55 30 Health and Safety Information For information and advice regarding transportation, handling, storage and disposal of chemical products, users shall refer to the actual Material Safety Data Sheets containing physical, ecological, toxicological and other safetyrelated data. Legal Notes The information, and, in particular, the recommendations relating to the application and end-use of Sika products, are given in good faith based on Sika's current knowledge and experience of the products when properly stored, handled and applied under normal conditions in accordance with Sika's recommendations. In practice, the differences in materials, substrates and actual site conditions are such that no warranty in respect of merchantability or of fitness for a particular purpose, nor any liability arising out of any legal relationship whatsoever, can be inferred either from this information, or from any written recommendations, or from any other advice offered. The user of the product must test the product’s suitability for the intended application and purpose. Sika reserves the right to change the properties of its products. The proprietary rights of third parties must be observed. All orders are accepted subject to our current terms of sale and delivery. Users must always refer to the most recent issue of the local Product Data Sheet for the product concerned, copies of which will be supplied on request. Sika® Glazing Tape Prefix 2 / 2 Method of Application Surface preparation The bond face must be clean and free of contaminants such as dust, oil and grease. Advice on specific applications is available from the Technical Service Department of Sika Industry.
© Copyright 2026 Paperzz