Now sold under the Fisher HamiltonScientific Scientific brand www.hamiltonscientific.com Laboratory Fume Hood L A B O R AT O R Y F U M E H O O D S . . . the new frontier of enhanced performance and energy efficiency! Designed to maximize containment performance and energy efficiency, Pioneer is the first laboratory fume hood to utilize Directed Airflow Technology™. A unique laminar airflow control module is positioned directly above the operator’s breathing zone. Except when being loaded, fume hoods are intended to be used with the sash lowered to an operating position. When the Pioneer sash is opened above the 18" operating position, the control module automatically activates, directing a flow of room air between the operator and the fume hood interior. This directed airflow helps purge the operator’s breathing zone. The innovative Pioneer airflow system provides enhanced performance and energy efficiency at lower face velocities. Subjected to both standard and modified ASHRAE test procedures, the Pioneer has been tested at face velocities as low as 50 fpm, sash fully open, with unmatched performance. Directed Airflow Technology™ . . . the secret behind Pioneer’s exceptional performance! Setup Position – Pioneer sash above 18" to full open - laminar flow control module activated. Operating Position – Pioneer sash at 18" to closed - laminar flow control module deactivated. Features * 35" Chain and Sprocket Sash Support System Pioneer sash counterbalance system features chain and sprocket sash support system with alignment shaft and sash leveling device. Laminar Airflow Control Module Directed air flow helps to purge operator’s breathing zone with room air when sash is raised above the 18" operating positon. CL A S S IFIE UL D AutoSash Automatic Positioning System Sash locks in setup position and automatically returns to maximum operational height when lock is released. 35" High Sightline Viewable face opening is 35" high for optimum visibility of hood interior. R 1805 UL 1805 Classified All Fisher Hamilton Pioneer Fume Hoods meet the requirements of the UL 1805 Classification. Low Profile Sill Airfoil Ergonomically designed airfoil provides obstructionfree access to hood interior. *Several patents have been applied for and are pending. Fixed Baffle System Pioneer baffle system requires no adjustment – it’s factory-tuned for optimal airflow characteristics. Pioneer Dual Performance Monitor A multifunction control system monitors the sash opening and the directed airflow system. When the sash is raised above the 18" operating position, an intermittent audio warning, a warning light and the directed air module are activated. Visual and audible alarms are triggered if the directed air flow system does not operate when the sash is raised above 18". On the combination sash hood, a visual warning activates when the sash is raised to remind the user to close sash panels. Ordering Information - Superstructures 70.5" Unframed Sash 73.5" Combination Sash 53" 37-1/4" Product Numbers Restricted Bypass Vertical Rising Unframed Sash Restricted Bypass Combination Sash 37-1/4" Depth Width 37-1/4" Depth Width 61L655P0 61L656P0 61L657P0 61L658P0 61L659P0 48" 60" 72" 84" 96" 61L655PB 61L656PB 61L657PB 61L658PB 61L659PB 48" 60" 72" 84" 96" Includes front ceiling/sash enclosure Add the following suffix letter to product numbers at left for side panel requirements: U = Without side panels, L = Left side only, R = Right side only, B = Both sides. Includes front ceiling/sash enclosure Ordering Information - Work Surface Product Numbers 37-1/4" Depth Add the following suffix letters to product numbers at left for cupsink cutout requirements: 000 = No cupsink cutouts, 1LF = Left Front, 1RF = Right Front, 2BF* = Both Front Sides, 1LR = Left Rear, 1RR = Right Rear. Hood Width 21L4830 21L6030 21L7230 21L8430 21L9630 48" 60" 72" 84" 96" *96" width only Technical Data Pioneer Fume Hood with Vertical Sash Hood Width Exhaust Volume 48" 440 60" 580 72" 715 84" 855 96" 990 Pioneer Fume Hood with Combination Sash Sash Opening Vertical Sash Opening Height Nominal Face Velocity 18 27.5 18 27.5 18 27.5 18 27.5 18 27.5 92 60 92 60 92 60 92 60 92 60 Static Pressure Exhaust Collar Size Hood Width Exhaust Volume .08" 6" x 15" 48" 440 .08" 6" x 23" 60" 580 .12" 6" x 23" 72" 715 .14" 6" x 26" 84" 855 .08" 6" x 30" 96" 990 Vertical Sash Height 18 27.5 18 27.5 18 27.5 18 27.5 18 27.5 Horizontal Sash Opening Nominal Face Velocity Sliding Sash Static Panels Vertical Horizontal Pressure 28.5 x 17.375 2 28.5 x 23.375 2 28.5 x 28.250 4 28.5 x 34.250 4 28.5 x 40.250 4 92 60 92 60 92 60 92 60 92 60 110 .08" 6" x 15" 110 .08" 6" x 23" 110 .12" 6" x 23" 110 .14" 6" x 26" 110 .08" 6" x 30" The Pioneer fume hood must be equipped with an air flow monitoring device, as recommended by NFPA. Now sold under the Hamilton Scientific brand www.hamiltonscientific.com Fisher Hamilton L.L.C. 1316 18th Street, P.O. Box 137 Two Rivers, WI 54241 Tel: 920-793-1121 Fax: 920-793-3084 www.fisherhamilton.com AL-1426-4 JULY03 USA ©2003 Fisher Hamilton L.L.C. Exhaust Collar Size
© Copyright 2026 Paperzz