WINDOWS & DOORS SOUTH LANARKSHIRE COUNCIL Town & Country Planning (Scotland) Acts APPROVED IN TERMS OF CONSENT OF 04 Jan 2013 Michael McGlynn Head of Planning and Building Standards Services A L L LOW LEVEL G L A Z I N G TO B E TO B S 6 2 6 2 A N D A L L UPVC A P P L I C A T I O N S TO B S 7 4 1 2 : 2 0 0 7 NEW WINDOW G L A Z I N G TO C O M P R I S E OF A R G O N FILLED UNITS TO PROVIDE A U-VALUE OFF 1.1 W / M 2 K A L L WINDOWS TO B E FITTED WITH P E R M A V E N T S A T H E A D . G L A Z I N G T H R O U G H O U T TO B E TO B S : 6 2 6 2 . T 0 U G H E N E D G L A S S ON A L L WINDOWS WITH CILLS B E L O W S O O m m NEW TILT A N D TURN WINDOWS TO PROVIDE FIRE E S C A P E WINDOW NEW WINDOWS TO U P P E R FLOOR A R E A S TO M A T C H EXISTING WINDOWS WITH TILT N TURN UNITS FITTED WITH D O U B L E G L A Z E D UNITS TO B E C L E A N A B L E S A F E L Y F R O M THE INSIDE, A N D PROVIDE E M E R G E N C Y E S C A P E TO A L L U P P E R FLOOR PUBLIC A R E A S M A X l l O O m m O F F THE FIN FLOOR LEVEL. S S O m m WHITE F A N E L P A S S D O O R S THRO'OUT U N L E S S INDICATED NEW WINDOWS T H R O U G H O U T TO B E HIGH P E R F O R M A N C E UPVC WINDOWS TO M A T C H EXISTING A L L WINDOWS TO B E FITTED A T H E A D WITH P E R M A V E N T S A L L N E W D O O R S A N D WINDOWS TO B E TO I N S T A L L E D TO B S 7 9 5 0 :1997 & B S F A S 2 4 : 2 0 0 7 & I N S T A L L E D TO P R E V E N T UNLAWFUL E N T R Y Existing Rear Elevation Scale WOO EXTERNAL HNISHES NEW E X T E R N A L F I N I S H E S TO M A T C H EXISTINC5 BUILDING M A T E R I A L IN COLOUR A N D TEXTURE A S FOLLOWS : ROOF : S L A T E G R E Y M A R L E Y M O D E R N CONCRETE TILES F A S C I A -1- V E R G E : UFVC F A S C I A THROUGHOUT G U T T E R / R W r S / S V R ' S : M A R L E Y UPVC DOWNFIFES W A L L S : F A C I N G BRICK TO EXTENSION D A D O W A L L S : F A C I N G BRICK. WINDOWS : WHITE UFVC D O O R S : WHITE UFVC SILLS : ISOmm CONCRETE SILLS ROOF FINISH TO B E M A R L E Y M O D E R N INTERLOCKING C O N C R E T E ROOF TILES WITH M A T C H I N G R I D G E A N D D R Y V E R G E D E T A I L S TO M A T C H EXISTING UFVC F A C I N G S T H R O U G H O U T TO V E R G E A N D F A S C I A INCLUDING R E P L A C I N G EXISTING TO M A T C H EXISTING WITH M A R L E Y D R Y - V E R G E A N D DRY E A V E S UNITS E X T E R N A L D O O R S A N D WINDOWS TO B E UFVC TO M A T C H EXISTING A L L WINDOWS S U P P L I E D TO S I Z E S SHOWN ON P L A N S AND ELEVATIONS WHITE UFVC FINISH TO E X T E R N A L F A C E WHITE UPVC FINISH INTERNALLY THROUGHOUT MAKLEY DRY RIDGE EAVES AND VERGE SYSTEM TO NEW G A B L E END OF ROOF TO MATCH EXISTING DRY VERGE. RIDGE AND EAVES SOFFIT TO MATCH EXISTING 250mm SOFFIT LEVEL ON THROUGHOUT MINIMUM OFEMIMCr AFBA MIN leomrn MIN LEAD ABUTMENT FLASHING D K B S e E D UP FACE OF EXISTING WALL FOK E S C A P E 1 U WINDOW TO BF (finn K r~ f^r-t r— ..^ ^ A >• »^ NO CAVITY TRAYS REQUIRED WHERE NEW ROOF MEETS THE EXISTING ROUGHCASTED WALL FIRE STOPS TO BE PROVIDED HORIZONTALLY BETWEEN STOREYS AND AT ALL CORNERS PERPEND VENTS TO BE AT FLOOR LEVEL. BELOW SILLS, BELOW EAVES, ABOVE AND BELOW HORIZONTAL FIRE STOPS AND BELOW FIRESTOP AT TOP OF VERGES TO BOTH G A B L E S ALL WINDOWS TO BE FITTED WITH PERMAVENTS AT HEAD. GLAZING THROUGHOUT TO BE TO 6 3 : 6 2 6 2 . TOUGHENED G L A S S ON ALL WINDOWS WITH CILLS BELOW SOOmm ALL LOW LEVEL GLAZING TO BE TO B S 6 2 6 2 NEW WINDOW GLAZING TO COMPRISE OF ARGON FILLED UNITS TO PROVIDE A U VALUE OFF 1.1 W/M2K PERPEND VENTILATORS P E R P E N D VENTILATORS TO B E PROVIDED TO A L L NEW E X T E R N A L W A L L S A T FLOOR A N D CEILING L E V E L S P E R P E N D V E N T S TO B E A T FLOOR LEVEL. BELOW S I L L S , B E L O W E A V E S . A B O V E A N D BELOW HORIZONTAL FIRE S T O P S A N D B E L O W FIRE S T O P A T TOP OF V E R G E S TO BOTH G A B L E S CAVITY W E E P V E N T S A T l O O O m m C R S A B O V E CAVITY FILL L E V E L CAVITY TO B E V E N T E D TO OUTSIDE B Y O N E O P E N P E R P E N D JOINT A T MIN OF 1.2M C / C . TOP A N D BOTTOM. NEW PERPEND VENTS ABOVE FLASHING ON EXISTING REAR WALL ABOVE NEW ROOF LEVEL D P E R P E N D VENTS AT 1200mm CRS L A N D I N G S REQUIRED FOR A L L S T E P S T H A T E X C E E D S O O m m . M A X RISE OF S T E P S TO B E 170mm M A X G O I N G 2 5 0 m m . C O N C R E T E P L A T T EXTENDED MIN 4 0 0 m m B E Y O N D M A X S W I N G OF NEW DOOR IN O P E N E D POSITION \ bm design UNIT 25 COLVILLES PARK Kelvin lnt:iuet.rlal Ee-tate E a s t Kilbride G 7 5 OGZ Tel : 07677269321 THIS IS THE PRINCIPAL / A TRUE COPY OF THE PLANS REFERRED TO IN THE ACCOMPANYING APPLICATION FOR PLANNING PERMISSION AND BUILDING WARRANT SIGNED : MR BRIAN MCATEER PATEP : MTH OCTOBER 2012 APPUCAMT MR BRIAN MCATEER UNIT 25 COLVILLES PARK EAST KILBRIDE G75 OGZ SITE ADDRESS 27 DOUOLAS STREET HAMILTON ML3 OBP Proposed Rear Elevation S c a l e 1:50i PROJECT FROPOSEP EXTENSION TO REAR OF HOUSE AND ASSOCIATED CAR PARKING. PROPOSEP CHANGE OF USE TO PENTAL PRACTISE SCAU 1:1001:50 BM 9 2 0 TITLE EXISTING & PROPOSEP REAR ELEVATIONS DRG NO. 1 O 0 F 1 3 REVA
© Copyright 2026 Paperzz