Existing Rear Elevation Proposed Rear Elevation

WINDOWS & DOORS
SOUTH LANARKSHIRE COUNCIL
Town & Country Planning (Scotland) Acts
APPROVED
IN TERMS OF CONSENT OF
04 Jan 2013
Michael McGlynn
Head of Planning and Building Standards
Services
A L L LOW LEVEL G L A Z I N G TO B E TO B S 6 2 6 2
A N D A L L UPVC A P P L I C A T I O N S TO B S 7 4 1 2 : 2 0 0 7
NEW WINDOW G L A Z I N G TO C O M P R I S E OF
A R G O N FILLED UNITS TO PROVIDE A U-VALUE
OFF 1.1 W / M 2 K
A L L WINDOWS TO B E FITTED WITH P E R M A V E N T S
A T H E A D . G L A Z I N G T H R O U G H O U T TO B E TO
B S : 6 2 6 2 . T 0 U G H E N E D G L A S S ON A L L WINDOWS
WITH CILLS B E L O W S O O m m
NEW TILT A N D TURN WINDOWS TO PROVIDE
FIRE E S C A P E WINDOW
NEW WINDOWS TO U P P E R FLOOR A R E A S TO M A T C H
EXISTING WINDOWS WITH TILT N TURN UNITS FITTED
WITH D O U B L E G L A Z E D UNITS TO B E C L E A N A B L E
S A F E L Y F R O M THE INSIDE, A N D PROVIDE
E M E R G E N C Y E S C A P E TO A L L U P P E R FLOOR PUBLIC
A R E A S M A X l l O O m m O F F THE FIN FLOOR LEVEL.
S S O m m WHITE F A N E L P A S S D O O R S THRO'OUT
U N L E S S INDICATED
NEW WINDOWS T H R O U G H O U T TO B E HIGH
P E R F O R M A N C E UPVC WINDOWS TO M A T C H
EXISTING A L L WINDOWS TO B E FITTED A T
H E A D WITH P E R M A V E N T S
A L L N E W D O O R S A N D WINDOWS TO B E TO
I N S T A L L E D TO B S 7 9 5 0 :1997 & B S F A S 2 4 : 2 0 0 7
& I N S T A L L E D TO P R E V E N T UNLAWFUL E N T R Y
Existing Rear Elevation
Scale WOO
EXTERNAL HNISHES
NEW E X T E R N A L F I N I S H E S TO M A T C H EXISTINC5
BUILDING M A T E R I A L IN COLOUR A N D TEXTURE
A S FOLLOWS : ROOF : S L A T E G R E Y M A R L E Y M O D E R N CONCRETE TILES
F A S C I A -1- V E R G E : UFVC F A S C I A THROUGHOUT
G U T T E R / R W r S / S V R ' S : M A R L E Y UPVC DOWNFIFES
W A L L S : F A C I N G BRICK TO EXTENSION
D A D O W A L L S : F A C I N G BRICK.
WINDOWS : WHITE UFVC
D O O R S : WHITE UFVC
SILLS : ISOmm CONCRETE SILLS
ROOF FINISH TO B E M A R L E Y M O D E R N INTERLOCKING
C O N C R E T E ROOF TILES WITH M A T C H I N G R I D G E A N D
D R Y V E R G E D E T A I L S TO M A T C H EXISTING
UFVC F A C I N G S T H R O U G H O U T TO V E R G E A N D F A S C I A
INCLUDING R E P L A C I N G EXISTING TO M A T C H EXISTING
WITH M A R L E Y D R Y - V E R G E A N D DRY E A V E S UNITS
E X T E R N A L D O O R S A N D WINDOWS TO B E UFVC TO
M A T C H EXISTING
A L L WINDOWS S U P P L I E D TO S I Z E S SHOWN ON P L A N S
AND ELEVATIONS
WHITE UFVC FINISH TO E X T E R N A L F A C E
WHITE UPVC FINISH INTERNALLY THROUGHOUT
MAKLEY DRY RIDGE EAVES AND VERGE
SYSTEM TO NEW G A B L E END OF ROOF TO
MATCH EXISTING
DRY VERGE. RIDGE AND EAVES
SOFFIT TO MATCH EXISTING 250mm SOFFIT
LEVEL ON THROUGHOUT
MINIMUM
OFEMIMCr AFBA
MIN leomrn MIN LEAD ABUTMENT FLASHING
D K B S e E D UP FACE OF EXISTING WALL
FOK E S C A P E
1 U WINDOW
TO BF (finn K
r~
f^r-t
r—
..^
^
A
>•
»^
NO CAVITY TRAYS REQUIRED WHERE NEW ROOF
MEETS THE EXISTING ROUGHCASTED WALL
FIRE STOPS TO BE PROVIDED HORIZONTALLY
BETWEEN STOREYS AND AT ALL CORNERS
PERPEND VENTS TO BE AT FLOOR LEVEL.
BELOW SILLS, BELOW EAVES, ABOVE AND
BELOW HORIZONTAL FIRE STOPS AND BELOW
FIRESTOP AT TOP OF VERGES TO BOTH G A B L E S
ALL WINDOWS TO BE FITTED WITH
PERMAVENTS AT HEAD. GLAZING
THROUGHOUT TO BE TO 6 3 : 6 2 6 2 .
TOUGHENED G L A S S ON ALL WINDOWS
WITH CILLS BELOW SOOmm
ALL LOW LEVEL GLAZING TO BE TO B S 6 2 6 2
NEW WINDOW GLAZING TO COMPRISE OF
ARGON FILLED UNITS TO PROVIDE A U VALUE
OFF 1.1 W/M2K
PERPEND VENTILATORS
P E R P E N D VENTILATORS TO B E PROVIDED TO A L L NEW
E X T E R N A L W A L L S A T FLOOR A N D CEILING L E V E L S
P E R P E N D V E N T S TO B E A T FLOOR LEVEL. BELOW S I L L S ,
B E L O W E A V E S . A B O V E A N D BELOW HORIZONTAL FIRE
S T O P S A N D B E L O W FIRE S T O P A T TOP OF V E R G E S TO
BOTH G A B L E S
CAVITY W E E P V E N T S A T l O O O m m C R S A B O V E CAVITY
FILL L E V E L
CAVITY TO B E V E N T E D TO OUTSIDE B Y O N E O P E N
P E R P E N D JOINT A T MIN OF 1.2M C / C . TOP A N D BOTTOM.
NEW PERPEND VENTS ABOVE FLASHING ON EXISTING
REAR WALL ABOVE NEW ROOF LEVEL
D P E R P E N D VENTS AT 1200mm CRS
L A N D I N G S REQUIRED FOR A L L S T E P S T H A T
E X C E E D S O O m m . M A X RISE OF S T E P S TO B E
170mm M A X G O I N G 2 5 0 m m . C O N C R E T E P L A T T
EXTENDED MIN 4 0 0 m m B E Y O N D M A X S W I N G
OF NEW DOOR IN O P E N E D POSITION
\
bm design
UNIT 25 COLVILLES PARK
Kelvin lnt:iuet.rlal Ee-tate
E a s t Kilbride G 7 5 OGZ
Tel : 07677269321
THIS IS THE PRINCIPAL / A TRUE COPY OF THE PLANS REFERRED TO IN THE
ACCOMPANYING APPLICATION FOR PLANNING PERMISSION AND BUILDING WARRANT
SIGNED : MR BRIAN MCATEER
PATEP : MTH OCTOBER 2012
APPUCAMT
MR BRIAN MCATEER
UNIT 25 COLVILLES PARK
EAST KILBRIDE G75 OGZ
SITE ADDRESS
27 DOUOLAS STREET
HAMILTON
ML3 OBP
Proposed Rear Elevation
S c a l e 1:50i
PROJECT
FROPOSEP EXTENSION TO REAR OF HOUSE AND ASSOCIATED CAR PARKING.
PROPOSEP CHANGE OF USE TO PENTAL PRACTISE
SCAU 1:1001:50
BM 9 2 0
TITLE
EXISTING & PROPOSEP REAR ELEVATIONS
DRG NO. 1 O 0 F 1 3
REVA