K-SYSTEMS - DESIGNED FOR ART THE IVF TRI-GAS INCUBATOR FOR GAMETES AND EMBRYOS • • • • • • • • • Designed for ART with stable temperature and gas environment conditions Low oxygen range adjustable for 2-20% Grade A air quality Recovery to homeostatic conditions CO2 < 2min ; N2 < 4min* No premixed gas required - just connect to pure CO2 and/or N2 Minimized risk of cross-contamination - one incubation chamber per patient Data logging for process parameters and alarm functions Up to 40 individual dishes in one incubator SMS Alarm to your cell phone Direct warming of the dishes Easy cleaning - rounded edges G185 SensorTech - for improved external quality control Option for pH Monitoring via MTG pH Online System Option for external CO2 and Temperature Quality Control www.k-systems.dk K-SYSTEMS LONGTERM INCUBATOR G185 Common Laboratory Pains G185 Laboratory Solutions • Expensive space utilization • No space availability • Limits work efficiencies • Optimize space utilization • Up to 3 units per cabinet • Fluidity in work • Designed for Life Science • No Direct Heat • Limitation of dishes per compartment • Designed for ART • Direct heat to the dish • 1 chamber takes up to 4 dishes • Large volume = slow recovery of gas and temperature • High operating costs due to high gas consumption • Fast recovery to homeostatic conditions • CO2 & O2 recovers in < 3 min • Very low gas consumption: 1 l/h of CO2 Specifications G185 Standard G185 SensorTech 22110 22200 850x558x152.5 mm 850x558x152.5 mm 2-10% / 2-20% 2-10% / 2-20% Connection to 100% CO2 and 100% N2 √ √ Recovery Time < 3 min √ √ 1 l/h of CO2 & 12 l/h of N2 1 l/h of CO2 & 12 l/h of N2 √ √ OrderCode Overall dimensions (WxDxH) CO2 / O2 range Gas consumption (all lids closed; CO2 and O2 setpoint: 5.0% Internal Air Quality—Grade A Ambient to 49.9°C Ambient to 49.9°C Datalogger system on one computer (XP Service Pack II/III, Home, Pro or Vista and Win7) Temperature range √ √ Decontamination Programme √ √ Prepared for Ph Monitoring √ Prepared for external CO2 and temperature sensors for enhanced quality control √ SMS Alert function (option) √ Warming Block Inserts The 10 chambers are prepared for a flat warming block insert. The warming blocks are customized for either Falcon or Nunc and can take up to 4 dishes. Sensors for External Control • The system is prepared for a high precision CO2 sensor (0-10%) from Vaisala (GMP221). • The temperature sensor should be a standard pin sensor with a PT100 element (150mm—Ø; 3mm) √ *Measurement observed with setpoint at 5% on both gasses, all lids closed and gasses stabilised. www.k-systems.dk Both sensors can be connected to a variety of measurement devices.
© Copyright 2026 Paperzz