4.0 Preliminary Secant Pile Design 3.0 Load Take Down HEYNETILLETTSTEEL Project: Title: 1095 - Project Merion Load Takedown Column Location: Car Lifts A / E1-E3 PROPOSED Level Roof 4th 3rd 2nd 1st Ground Lower Ground Basement Pile Cap SSL (m) 39.540 36.165 32.790 29.415 26.040 21.315 17.775 14.375 13.875 Summary of Loads Dead Load (kN) Live Load (kN) TOTAL Load (kN) Area L N/A N/A N/A N/A N/A N/A N/A N/A N/A W N/A N/A N/A N/A N/A N/A N/A N/A N/A Area (m2) 167.4 167.4 167.4 167.4 186.4 220.5 220.5 220.5 97.6 Floor Loads DL (kN/m2) LL (kN/m2) 9.60 8.55 8.55 8.55 8.55 8.55 8.55 13.65 18.00 1.50 2.50 2.50 2.50 2.50 2.50 2.50 2.50 0.00 Column Loads Storey Height (m) Weight (kN/m) 0.00 0.00 3.38 127.75 3.38 127.75 3.38 127.75 3.38 127.75 4.73 232.90 3.54 281.62 3.40 244.27 0.00 0.00 External Cladding Loads Length (m) Weight (kN/m) 0.00 0.00 31.56 3.34 31.56 3.34 31.56 3.34 31.56 3.34 22.14 3.34 0.00 0.00 0.00 0.00 0.00 0.00 Total Loads Gk (kN) Qk (kN) 1607 251 1968 419 1968 419 1968 419 2130 466 3060 551 2882 551 3840 551 1757 0 21179 3626 Foundation Loads 21179 3626 24806 TOTAL Load (kN) Pile Capcity (kN) No. of Piles Required kN/m2 Live 24806 1270 19.5 Design Loads Roof Dead 250mm RC Slab 75mm Screed Asphalt Waterproofing and Insulation Finishes - Paving Slab Ceiling and Services 6.00 1.65 0.45 1.20 0.30 9.60 kN/m2 1.50 Typical Floor Dead 250mm RC Slab 75mm Screed Finishes Ceiling and Services kN/m2 6.00 1.65 0.60 0.30 8.55 Live Residential Partitions OR Circulation kN/m2 1.50 1.00 2.50 3.00 Basement Dead 500mm RC Slab 75mm Screed Pile Cap kN/m2 12.00 1.65 13.65 Live Car Park OR Circulation J:\1095ͲProjectMerion\4Calculations\LoadTakedownͲSO'B(140313).xlsx kN/m2 2.50 Dead 750mm Deep kN/m2 18.00 18.00 3.00 CarLifts HEYNETILLETTSTEEL External Cladding Dead Internal - 140mm Blockwork Cavity External - 102.5mm Brickwork Glazing kN/m2 2.80 0.00 2.26 0.75 Assumed % 60 40 kN/m2 1.68 0.00 1.36 0.30 3.34 RC Walls Dead RC Walls - vary in thickness and length Approx. Area 5.323m2 kN/m 127.75 127.75 Dead RC Walls - vary in thickness and length Approx. Area 9.704m2 kN/m 232.90 232.90 Dead RC Walls - vary in thickness and length Approx. Area 11.734m2 kN/m 281.62 281.62 Dead RC Walls - vary in thickness and length Approx. Area 10.178m2 kN/m 244.27 244.27 J:\1095ͲProjectMerion\4Calculations\LoadTakedownͲSO'B(140313).xlsx CarLifts PILEDESIGNS Ltd. Page: 1 PILEDESIGNS Ltd. Page: 2 Project: Project Merion, Holland Park, LONDON Date: 19/06/2014 Project: Project Merion, Holland Park, LONDON Date: 19/06/2014 Design By: JBP Rev: 0 Design By: JBP Rev: 0 Job No: Design Ref: 15614 Job No: Design Ref: 15614 CONTENTS PRELIMINARY / OUTLINE SECANT BORED PILED RETAINING WALL DESIGN 1.0 INTRODUCTION 2.0 INFORMATION PROVIDED 3.0 FOR TEMPORARY AND PERMANENT SUPPORT CONDITIONS AT 4.0 PROJECT MERION HOLLAND PARK LONDON 2.1 General and Structural Arrangements for the Proposed Development. 2.2 Ground Conditions. DESIGN PARAMETERS 3.1 Geotechnical Design Parameters. 3.2 Construction Sequence Adopted Within the Design Calculations. 3.3 Structural Design Parameters. 3.4 Retaining Wall and Propping Geometry. DESIGN METHODOLOGY 4.1 Geotechnical Analysis for the Secant Bored Pile Retaining Wall. 4.2 Individual Retaining Wall Structural Analysis. 5.0 SUMMARY OF RESULTS AND GENERAL COMMENTS 6.0 REFERENCES APPENDICES Initial Issue 0 Stage Revision Preliminary Design Calculations for Planning Comments 19/06/2014 Date A Selected ‘WALLAP’ SLS and ULS output for the various wall sections considered. B ‘ADCOL’ outputs for the various reinforcement cages required together with the in-house designed spread sheet output for the helical shear link reinforcement. PILEDESIGNS Ltd. Page: 3 PILEDESIGNS Ltd. Page: 4 Project: Project Merion, Holland Park, LONDON Date: 19/06/2014 Project: Project Merion, Holland Park, LONDON Date: 19/06/2014 Design By: JBP Rev: 0 Design By: JBP Rev: 0 Job No: Design Ref: 15614 Job No: Design Ref: 15614 List of Figures 1.0 1. It is proposed to demolish an existing residential block of flats dating from the 1930’s replacing it with a modern structure which will incorporate an underground car park. Plan showing the required bored pile retaining wall, the sections considered within the design. List of Tables 1. Geotechnical Design Parameters 2. Retaining Wall Structural Design Parameters. 3. Temporary / Permanent Propping Structural Design Parameters. 4. Results of Retaining Wall Analysis. 5. Structural Details of Retaiing Wall Piles. 6. Details of Prop Forces. INTRODUCTION The new building will be located in the Holland Park area of London on sloping ground that requires a significant amount of material to be excavated in order to create the necessary plan surface area. As part of these earthworks / enabling works, a retaining wall will be required around the perimeter of the site. It is proposed to construct the retaining wall using interlocking secant piles using bored piling techniques whilst at the same time installing the internal bearing piles during the same visit. The existing building fronts onto Holland Park Road which bounds the western edge of the site. A steep pedestrian path, Holland Park Walk, borders the eastern edge of the site. Holland Park Avenue lies just to the north and the park itself borders the southern site boundary. Information from the topographic survey indicates that the site has a steep slope from the east to the west falling from around 29.0m AOD on the eastern side to around 21.0m AOD on the western side. It is expected that due to the large variation in retained heights required, a minimum of three pile diameters will be employed on the site These preliminary design calculations cover the required temporary / permanent secant bored pile retaining walls. At this stage of the design process the pile sizes have been estimated and the ground conditions modelled from the results of the ground investigation results. A “WALLAP” retaining wall analysis has been carried out to give an indication of the expected lateral forces to be resisted by the temporary and permanent propping to be installed. An indication of the theoretical deflection of the wall has also been included. The position of the new basement retaining walls are shown on the site plan, presented on Figure 1. This also shows the sections taken for the design of the secant bored pile retaining walls. These calculations have been carried out by Piledesigns Limited on behalf of Hyne Tillett Steel, Structural Engineers. PILEDESIGNS Ltd. Page: 5 Project: Project Merion, Holland Park, LONDON Date: 19/06/2014 Design By: JBP Rev: 0 Job No: Design Ref: 15614 Figure 1 – Plan showing the required bored pile retaining wall and the sections considered. PILEDESIGNS Ltd. Page: 6 PILEDESIGNS Ltd. Page: 7 Project: Project Merion, Holland Park, LONDON Date: 19/06/2014 Project: Project Merion, Holland Park, LONDON Date: 19/06/2014 Design By: JBP Rev: 0 Design By: JBP Rev: 0 Job No: Design Ref: 15614 2.0 INFORMATION PROVIDED 2.1 General and Structural Arrangements for the Proposed Development Details of the proposed building are presented in the Structural Stage C Report prepared by Heyne Tillett Steel, Structural Engineers. To provide an indication of the likely requirements for the secant piled retaining wall three sections have been analysed as indicated on the site plan, Figure 1. The sections have been chosen to represent the general structural requirements of the retaining walls and have been located where the worst case conditions are expected to apply. The three sections relate to the three sizes of pile diameter that are likely to be required around the excavation. 600mm Diameter Secant Pile Wall This section is located along the western front of the site where it fronts onto Holland Park Road. Within this analysis, the short section of internal retaining wall along Grid Line A3 has also been included although the retained heights are lower. For this section (as indicated on Figure 1) the following worst case design criteria have been adopted; x x x x x x x x 2.0m wide pavement – surcharge 5kN/m² 6.0m wide road – surcharge 20kN/m² Piling Platform Level – 23.0m AOD 250mm thick basement slab at a SSL of 14.375m AOD (Slab to act as a prop) Formation level of excavation – 13.80m AOD 250mm thick lower ground slab at a SSL of 17.775m AOD (Slab to act as a prop) Temporary prop at centre of capping beam (22.50m AOD) prop to be a 457 x 10 CHS steel tube. 200mm thick permanent internal waterproof concrete lining wall. For this section the male and female piles have been assumed to be 600mm in diameter and installed at 900mm centres providing a ‘bite’ of 150mm into each side of the female pile. 750mm Diameter Secant Pile Wall This section extends from the southern end of the 600mm diameter secant wall to where the retaining wall intersects Grid Line E1 on the eastern side of the site. Due to the increasing retained height required as the retaining wall moves into the site, the pile diameter has had to be increased in size. Job No: Design Ref: 15614 For this section (as indicated on Figure 1) the following worst case design criteria have been adopted; x x x x x x x x x x A general surcharge of 5kN/m² for the area immediately behind the capping beam Piling Platform Level - 28.0m AOD 250mm thick basement slab at a SSL of 14.375m AOD (Slab to act as a prop) Formation level of excavation – 13.80m AOD 250mm thick lower ground slab at a SSL of 17.775m AOD (Slab to act as a prop) 250mm thick ground floor slab at a SSL of 21.315m AOD (Slab to act as a prop) 250mm thick first floor slab at a SSL of 26.04m AOD (Slab to act as a prop) Temporary prop at centre of capping beam (27.50m AOD) prop to be a 457 x 10 CHS steel tube. Temporary prop at centre of wall (21.00m AOD) prop to be a 457 x 10 CHS steel tube. 300mm thick permanent internal waterproof concrete lining wall. For this section the male and female piles have been assumed to be 750mm in diameter and installed at 1100mm centres providing a ‘bite’ of 200mm into each side of the female pile. 900mm Diameter Secant Pile Wall This section runs along the full length of the rear (eastern) side of the site from the end of the 750mm diameter section at Grid Line E1 to the end of the 600mm diameter section at Grid Line A3. Due to the increasing height of the wall to be retained and the absence of propping restraint from the ground and first floors, the pile diameter has had to be increased in size. For this section (as indicated on Figure 1) the following worst case design criteria have been adopted; x x x x x x x x A general surcharge of 5kN/m² for the area immediately behind the capping beam Piling Platform Level – 29.0m AOD 250mm thick basement slab at a SSL of 14.375m AOD (Slab to act as a prop) Formation level of excavation – 13.80m AOD 250mm thick lower ground slab at a SSL of 17.775m AOD (Slab to act as a prop – loads transferred by the buttresses that are to be encapsulated into the slab. Temporary prop at centre of capping beam (28.50m AOD) prop to be a 457 x 10 CHS steel tube. Temporary prop at centre of wall (21.00m AOD) prop to be a 457 x 10 CHS steel tube. 400mm thick permanent internal waterproof concrete lining wall. For this section the male and female piles have been assumed to be 900mm in diameter and installed at 1400mm centres providing a ‘bite’ of 200mm in to each side of the female pile. Due to the large retained height from capping beam level to the lower ground floor slab level, (approximately 11.50m) excessive bending moments are produced in the pile section even PILEDESIGNS Ltd. Page: 8 PILEDESIGNS Ltd. Page: 9 Project: Project Merion, Holland Park, LONDON Date: 19/06/2014 Project: Project Merion, Holland Park, LONDON Date: 19/06/2014 Design By: JBP Rev: 0 Design By: JBP Rev: 0 Job No: Design Ref: 15614 allowing for the presence of the buttresses. To make the wall model work, the reinforced concrete cast in place wailing beam that will be used for the mid–level temporary prop has been retained and used as a restraint beam spanning between the adjacent buttresses to transfer the lateral forces into the buttresses and then into the foundations. A second such wailing beam has been created at a level of 25.00m AOD for the same purpose. It is expected that the transfer wailing beams can be incorporated into the 400mm thick waterproof inner lining wall without adversely affecting the external appearance of the structure. 2.2 Job No: Design Ref: 15614 Ground Conditions Ground conditions have been taken from a site investigation carried out by Soiltechnics, environmental and geotechnical consultants reference No STL2706D-G01, dated April 2014. The results of the investigation showed that the site is underlain by a thin covering of Made Ground (0.50m thick) overlying weathered becoming un-weathered London Clay. The London Clay has relatively constant un-drained shear strength of 130kN/m² from ground level to 14.0m AOD after which the strength increases at a constant rate of around 9.21kN/m²/m. Groundwater was not recorded in any of the boreholes whilst drilling and in only one of the standpipe installations which is probably as a result of surface water infiltration. PILEDESIGNS Ltd. Page: 10 PILEDESIGNS Ltd. Page: 11 Project: Project Merion, Holland Park, LONDON Date: 19/06/2014 Project: Project Merion, Holland Park, LONDON Date: 19/06/2014 Design By: JBP Rev: 0 Design By: JBP Rev: 0 Job No: 3.0 DESIGN PARAMETERS 3.1 Geotechnical Design Parameters Design Ref: 15614 The pile design calculations have been based on the information provided. The soil parameters employed have generally been taken from the information provided, but also supplemented where necessary from published data and other ground investigation reports in the area. The analysis has considered un-drained conditions for the cohesive deposits and drained conditions for the granular deposits when applied to the temporary condition. For the permanent condition, all soil types have been changed to the drained condition where applicable. Table 1 Design Ref: 15614 Geotechnical Design Parameters Soil Type SLS Parameters ULS Parameters Fs = 1.0 Fs = 1.5 Un-drained, 1.2 Drained 3 Made Ground %XON'HQVLW\Ȗ N1P (Granular, Drained) Ø’ = 30° Ø’ = 25° 0.50m Thick E’ = 10 000kN/m² E’ = 8 334kN/m² 3RLVVRQ¶V5DWLRȘ 3RLVVRQ¶V5DWLRȘ K0 = 0.500 K0 = 0.577 7DQįa’/Tan Ø’ = 0.666 7DQįa’/Tan Ø’ = 0.666 7DQįp’/Tan Ø’ = 0.500 7DQįp’/Tan Ø’ = 0.500 Table 1 presents a summary of the geotechnical design parameters for each soil used in the design of the retaining walls. For each soil the SLS and ULS, drained and un-drained conditions have been indicated. Further details on how the design parameters are obtained are given in Section 4.0 of this report. Groundwater for the temporary condition has been taken as the toe level of the piles whilst for the long term, permanent condition, groundwater level has been taken as 1.0m below existing or final ground level whichever is lower. Job No: 3 %XON'HQVLW\Ȗ N1P 3 3 Weathered London Clay %XON'HQVLW\Ȗ N1P (Cohesive, Un-drained) Cu = 130kN/m² Cu = 86.7kN/m² To 14.0m AOD į&u įz = 0.0kN/m²/m į&u įz = 0.0kN/m²/m Eu = 600 Cu = 78 000kN/m² Eu = 600 Cu = 52 000kN/m² įEu įz = 0.0kN/m²/m į(u įz = 0.0kN/m²/m 3RLVVRQ¶V5DWLRȘ 3RLVVRQ¶V5DWLRȘ K0 = 1.0 K0 = 1.0 3 %XON'HQVLW\Ȗ N1P 3 Weathered London Clay %XON'HQVLW\Ȗ N1P (Cohesive, Drained) E’ = 0.77 Eu E’ = 0.77 Eu To 14.0m AOD Eu = 0.77 x 78 000 = 60 060kN/m² Eu = 0.77 x 52 000 = 40 055kN/m² į(¶ įz = 0.0kN/m²/m į(¶ įz = 0.0kN/m²/m Poisson’s RatLRȘ 3RLVVRQ¶V5DWLRȘ Ø’ = 25° Ø’ = 20.83° C’ = 0.0kN/m² C’ = 0.0kN/m² 7DQįa’/Tan Ø’ = 0.666 7DQįa’/Tan Ø’ = 0.666 7DQįp’/Tan Ø’ = 0.500 7DQįp’/Tan Ø’ = 0.500 K0 = 1.0 K0 = 1.0 %XON'HQVLW\Ȗ N1P PILEDESIGNS Ltd. Page: 12 PILEDESIGNS Ltd. Page: 13 Project: Project Merion, Holland Park, LONDON Date: 19/06/2014 Project: Project Merion, Holland Park, LONDON Date: 19/06/2014 Design By: JBP Rev: 0 Design By: JBP Rev: 0 Table 1 Job No: Design Ref: 15614 Geotechnical Design Parameters (Cont’d) 3.2 Job No: Design Ref: 15614 Construction Sequence Adopted Within the Design Calculations. The construction sequence adopted for the retaining wall has been assumed to be as follows Soil Type SLS Parameters ULS Parameters Fs = 1.0 Fs = 1.5 Un-drained, 1.2 Drained 3 Secant Piles. x x x x x x 3 London Clay %XON'HQVLW\Ȗ N1P (Cohesive, Un-drained) Cu at 14.00m AOD = 130kN/m² Cu at 14.00m AOD = 86.7kN/m² 14.00m AOD (+) į&u įz = 9.21kN/m²/m į&u įz = 6.14kN/m²/m Eu = 600 Cu = 78 000kN/m² Eu = 600 Cu = 52 000kN/m² į(u įz = 5 526kN/m²/m į(u įz = 3 684kN/m²/m 3RLVVRQ¶V5DWLRȘ 3RLVVRQ¶V5DWLRȘ x K0 = 1.25 K0 = 1.25 x 3 %XON'HQVLW\Ȗ N1P 3 London Clay %XON'HQVLW\Ȗ N1P (Cohesive, Drained) E’ = 0.77 Eu E’ = 0.77 Eu 14.00m AOD (+) Eu = 0.77 x 78 000 = 60 060kN/m² Eu = 0.77 x 52 000 = 40 055kN/m² į(¶ įz = 4 255kN/m²/m į(¶ įz = 2 826kN/m²/m 3RLVVRQ¶V5DWLRȘ 3RLVVRQ¶V5DWLRȘ Ø’ = 25° Ø’ = 20.83° C’ = 5.0kN/m² C’ = 4.16kN/m² 7DQįa’/Tan Ø’ = 0.666 7DQįa’/Tan Ø’ = 0.666 7DQįp’/Tan Ø’ = 0.500 7DQįp’/Tan Ø’ = 0.500 K0 = 1.25 K0 = 1.25 %XON'HQVLW\Ȗ N1P x x x x x x x x Apply external surcharges. Install bored piles and cast capping beam to all piles. Partially excavate and install upper temporary prop Partially excavate and install lower temporary prop Excavate to formation level of 13.80m AOD Cast basement floor slab at 14.375m AOD and part inner lining wall. (Slab to act as a prop in both the temporary and permanent condition) Cast lower ground floor slab at 17.775m AOD and part inner lining wall (slab to act as a prop in permanent condition). Cast ground floor slab at 21.315m AOD (Slab to act as a prop in both the temporary and permanent conditions – 750mm diameter piles only) Cast first floor slab at 26.04m AOD (Slab to act as a prop in both the temporary and permanent conditions – 750mm diameter piles only) Cast buttresses to eastern retaining wall, inner lining wall and integral wailing spreader beams between buttresses as necessary Remove lower temporary prop Remove upper temporary prop END OF TEMPORARY DESIGN CONDITIONS Change soil parameters to long term conditions. Apply long term ground water conditions END OF PERMANENT DESIGN CONDITIONS The above construction sequence must be followed exactly as any deviation could result in piles or props being overstressed. 3.3 Structural Design Parameters The male secant bored pile retaining wall piles will be constructed using a C35 designed concrete pump mix and ‘B’ (500N/mm²) grade main reinforcement bars with ‘B’ grade helical shear links. A minimum of 75 mm cover to the main reinforcement will be provided by propriety spacers. The female piles will be constructed out of a soft (less than 10N/mm²) concrete. The main structural design parameters used in the retaining wall analysis have been summarized in Table 2, PILEDESIGNS Ltd. Page: 14 PILEDESIGNS Ltd. Page: 15 Project: Project Merion, Holland Park, LONDON Date: 19/06/2014 Project: Project Merion, Holland Park, LONDON Date: 19/06/2014 Design By: JBP Rev: 0 Design By: JBP Rev: 0 Job No: Design Ref: 15614 Table 2 – Structural Retaining Wall Design Parameters MATERIAL SHORT TERM PARAMETERS Concrete E= 600mm Ø Auger 900mm centres I = 0.0070686 m4/m run EI = 197 921 kN/m²/m Concrete E= 750mm Ø Auger 1100mm centres I = 0.0141196 m4/m run EI = 395 349 kN/m²/m 2.8 x 10+7 kN/m² 2.8 x 10+7 kN/m² 2.8 x 10+7 kN/m² 3.4 I = 0.0070686 m4/m run EI = 98 960 kN/m²/m Table 3 presents the structural and geometrical properties of the propping that has been used in the design of the retaining wall. E= 1.40 x 10+7 kN/m² I = 0.0141196 m4/m run EI = 197 674 kN/m²/m E= 1.40 x 10+7 kN/m² 900mm Ø Auger 1400mm centres I = 0.023005 m4/m run EI = 644 140 kN/m²/m I = 0.023005 m4/m run EI = 322 070 kN/m²/m Inner Lining Wall 200mm thick I = 0.00067 m4/m EI = 18 760 kN/m²/m I = 0.00067 m4/m EI = 9 380 kN/m²/m 300mm thick I = 0.00225 m4/m EI = 63 000 kN/m²/m I = 0.00225 m4/m EI = 31 500 kN/m²/m I = 0.00534 m4/m EI = 149 520 kN/m²/m I = 0.00534 m4/m EI = 74 760 kN/m²/m 2.05 x 10+8 kN/m² E= Buttress (400mm thick, 2.5m deep spaced at 3.0m centres) I = 0.1736 m4/m EI = 4 860 800 kN/m²/m Retaining Wall and Propping Geometry 1.40 x 10+7 kN/m² E= E= Steel Design Ref: 15614 The retaining wall has been designed as a propped cantilever in the temporary condition with permanent propping consisting of the structural basement, lower ground floor and ground floor slabs (where applicable) of the proposed building. LONG TERM PARAMETERS Concrete 400mm thick Job No: E= 2.05 x 10+8 kN/m² I = 0.1736 m4/m EI = 2 430 400 kN/m²/m Table 3: Temporary / Permanent Propping Structural Design Parameters. Prop No Prop Elevation (Temp/Perm) 1 (Temp) 2 (Temp) 3 (Perm) 4 (Perm) 5 (Perm) 6 (Perm) (m AOD) 28.50 21.00 14.25 17.65 21.19 25.91 Prop Prop Spacing Sectional area (m²) (m) 5.00 0.014 5.00 0.014 1.00 0.250 1.00 0.250 1.00 0.250 1.00 0.250 Prop Young’s modulus (kN/m²) 2.05 x 10+8 2.05 x 10+8 1.40 x 10+7 1.40 x 10+7 1.40 x 10+7 1.40 x 10+7 Prop free length (m) 15.00 15.00 15.00 15.00 15.00 15.00 Should the construction sequence or propping system be changed from that assumed then the retaining wall design will need to be reassessed which could result in changes to the pile length and / or reinforcement. The temporary props have been estimated as being CHS Steel tubes of section size 457 x 10. The exact size and spacing of the temporary propping is the responsibility of the temporary works design engineer. Two ‘virtual‘ props have been created for the 900mm diameter secant wall using the concrete wailing beam employed for the mid-level temporary propping and a second wailing at 25.00m AOD. The wailing beams will be employed to transfer the lateral loads from the retaining wall into the buttresses and from there into the foundations. It is expected that these transfer beams can be incorporated into the 400mm thick inner lining wall. PILEDESIGNS Ltd. Page: 16 PILEDESIGNS Ltd. Page: 17 Project: Project Merion, Holland Park, LONDON Date: 19/06/2014 Project: Project Merion, Holland Park, LONDON Date: 19/06/2014 Design By: JBP Rev: 0 Design By: JBP Rev: 0 Job No: Design Ref: 15614 4.0 DESIGN METHODOLOGY 4.1 Geotechnical Analysis for the Secant Bored Pile Retaining Wall The stability analysis has been carried out using the computer program ‘WALLAP’ Version 6.05, developed by Geosolve. The input and output data from the analyses are presented in Appendix A. Two sets of WALLAP runs were carried out for each wall section considered, namely one for ULS (Ultimate Limit State) conditions to check overall wall stability for the embedment length given with the other analysis for SLS (Serviceability Limit State) conditions to calculate the induced bending moments and shear forces. The ULS calculations have been based on the 'Strength Factor' method, with factor M' set to 1.5 for un-drained parameters and 1.2 for drained parameters. These are in accordance with British Standard, BS8002 (1994) and CIRIA report reference C580 (2003). This first analysis is mainly to verify that the proposed embedment length, i.e. reinforced toe level, provides a nominal factor of safety against failure. Bending and shear forces are un-factored in any subsequent structural calculations. An allowance for over dig within the maximum excavation of 10% (or 0.5m whichever is greater) of the retained height (below a temporary prop where employed) has also been taken into account. The SLS calculations have assumed moderately conservative soil parameters using a 'Strength factor' of 1.0 and no allowance for possible over dig. This second calculation is to determine the factored bending and shear forces for any subsequent structural calculations and to determine the anticipated wall deflections. Reinforcement calculations are based on the worst case bending moments and shear values determined from the factored ULS and un-factored SLS calculations as indicated in Table 4 and summarized in the wall reinforcement schedule, Table 5. Temporary and permanent prop forces have been summarized in Table 6. Details of the soil input values used in the analyses and output results are presented within the WALLAP printouts, Appendix A. Calculated wall displacements and corresponding program outputs may be considered to be an upper bound estimate of long-term movements, due to the following factors: (a) Geotechnical parameters, pile stiffness and surcharges are considered to be reasonably conservative values. A more accurate assessment of wall displacements would require the input of 'actual' parameters to be obtained from more sophisticated laboratory testing. (b) The computer program does not consider the beneficial effects of structural elements such as a capping beam in this instance. Job No: Design Ref: 15614 (c) The computer program is a two-dimensional analysis program and does not consider the beneficial effects of geometrical features such as internal or external wall corners which increase its overall stiffness. (d) The computer program uses a Winkler spring analysis to determine the wall displacements, in which springs are used to represent a continuum and there is no transfer of shear stresses between springs. In general, the application of this concept leads to an overestimation of structural deformations; hence the resulting displacements may be over-predicted. 4.2 Individual Retaining Wall Pile Structural Analysis. Reinforcement requirements have been analysed for the sheer forces and bending moments indicated within the WALLAP outputs (Appendix A) and summarized in the wall schedule, (Table 4). The Oasys software program ‘ADCOL’ has been employed for this purpose and all bending moments and shear force calculations have been carried out in accordance with BS 8110. Helical shear reinforcement details have been calculated from an in house designed spread sheet which calculates the shear reinforcement in accordance with BS 8110. The results of the ‘ADCOL’ analyses together with the helical reinforcement spread sheet results are given in Appendix B. For all cases the concrete grade has been taken as C35 and a worst case axial load of 0kN considered. PILEDESIGNS Ltd. Page: 18 Project: Project Merion, Holland Park, LONDON Date: 16/06/2014 Design By: JBP Rev: 0 Job No: Design Ref: 15614 Table 4 – Results of Retaining Wall Analysis Wall Pile Section Diameter (mm) 600mm secant 750mm secant 900mm secant Pile Spacing (mm) Calculated SLS Results SLS Results Deflection Bending Moments Shear (SLS) Maximum Ultimate Maximum Ultimate x1.35 x1.35 (approx.) (mm) (kNm/m) (kNm/m) (kN/m) (kN/m) ULS Results Bending Moments Maximum Ultimate x1.0 (kNm/m) (kNm/m) ULS Results Ultimate Design values Shear Per pile at spacing Maximum Ultimate Given x1.0 Moment Shear (kN/m) (kN/m) (kNm) (kN) 600 900 39.0 302.8 408.8 194.3 262.3 362.1 362.1 258.9 258.9 368 237 750 1100 40.0 401.0 541.4 318.3 429.7 580.6 580.6 310.7 310.7 639 473 900 1400 26.0 1006.1 1358.2 473.0 473.0 948.3 948.3 514.3 514.3 1902 720 Notes: The worst case conditions have been analysed for this piling appraisal. As the design progresses it is expected that value engineering can be applied to reduce the amount of steel and perhaps rationalise the piling down to 2 diameters only. The use of contiguous bored piles might also give savings to the amount of steel and concrete. PILEDESIGNS Ltd. Page: 19 Project: Project Merion, Holland Park, LONDON Date: 16/06/2014 Design By: JBP Rev: 0 Job No: Design Ref: 15614 Table 5 – Details of Retaining Wall Piles (Stability criteria only) Wall Section Pile Diameter Pile Spacing Assumed Piling Level Retaining Wall Pile Length Retaining Wall Pile Toe Level Reinforcement Main Bars No (mm) (mm) (m AOD) (m) Size (m AOD) (mm) Length Helical Size @ Spacing (m) (mm) @ (mm) 600mm Secant 600 900 23.0 12.0 11.0 9 B 32 12.0 B 10 250 750 1100 28.0 18.0 10.0 13 B 32 18.0 B 12 250 900 1400 29.0 19.0 10.0 16 B 40 19.0 B 12 250 750mm Secant 900mm Secant Notes: Retaining wall reinforcement lengths are for stability criteria only. Axial loading on the wall piles may result in longer lengths. For ease of construction, economy and installation, composite reinforcement cages are likely to be employed. PILEDESIGNS Ltd. Page: 20 Project: Project Merion, Holland Park, LONDON Date: 16/06/2014 Design By: JBP Rev: 0 Job No: Design Ref: 15614 Table 6 – Details of Prop Forces Wall Section Prop Ref Purpose of Prop Level of Prop (Temp/Perm) (m AOD) 600mm Secant 750mm Secant 900mm Secant SLS Results Prop Force Un factored Temp / Perm (kN/m run) ULS Results Prop Force Un factored Temp / Perm (kN/m run) 1 (Temp) 22.50 78 99 2 (Perm) 14.25 301 203 3 (Perm) 17.65 374 464 1 (Temp) 27.50 100 97 2 (Temp) 21.00 299 399 3 (Perm) 14.25 534 448 4 (Perm) 17.65 363 486 5 (Perm) 21.19 468 503 6 (Perm) 25.91 70 82 1 (Temp) 28.50 103 92 2 (Temp) 21.00 344 478 3 (Perm) 14.25 654 426 4 (Perm) 17.65 832 1020 5 (Virtual) (Perm) 21.00 128 165 6 (Virtual) (Perm) 25.00 216 262 Notes: Propping forces are given for information only. Temporary propping to be designed by a Temporary Works Design Engineer. PILEDESIGNS Ltd. Page: 21 PILEDESIGNS Ltd. Page: 22 Project: Project Merion, Holland Park, LONDON Date: 19/06/2014 Project: Project Merion, Holland Park, LONDON Date: 19/06/2014 Design By: JBP Rev: 0 Design By: JBP Rev: 0 5.0 Job No: Design Ref: 15614 SUMMARY OF RESULTS AND GENERAL COMMENTS Summary results of the various retaining wall stability analyses are presented in Table 4. The pile summary schedule indicating required pile lengths and reinforcement is presented in Table 5 whilst temporary and permanent prop forces are presented in Table 6. Job No: Design Ref: 15614 REFERENCES: (1) BS 8002: 1994. Code of practice for earth retaining structures (2) BS 8004: 1986. Code of practice for foundations (3) BS 8110 – 1: 1997 (Rev.2005) The detailed retaining wall analysis comprising the computer print outs from ‘WALLAP’ are presented in Appendix A. Reinforcement calculations comprising the computer printouts from the ‘ADCOL’ design software and in-house designed link reinforcement spread sheet are presented in Appendix B. (4) CIRIA C580 (2003). Embedded retaining walls – guidance for economic design. PILEDESIGNS Ltd. APPENDIX A PILEDESIGNS Ltd. APPENDIX A Project: Project Merion, Holland Park, LONDON Date: 19/06/2014 Project: Project Merion, Holland Park, LONDON Date: 19/06/2014 Design By: JBP Rev: 0 Design By: JBP Rev: 0 Job No: Design Ref: 15614 Job No: Design Ref: 15614 APPENDIX A Ref No Description A-ULS A-SLS WALLAP analysis for 600mm secant, stability and embedment. WALLAP analysis for 600mm secant, moments and deflection. B-ULS B-SLS WALLAP analysis for 750mm secant, stability and embedment. WALLAP analysis for 750mm secant, moments and deflection. C-ULS C-SLS WALLAP analysis for 900mm secant, stability and embedment. WALLAP analysis for 900mm secant moments and deflection. WALLAP analysis for 600mm secant, (ULS) stability and embedment. | Sheet No. Revision A38.B55.R43 | Job No. 15614 Licensed from GEOSOLVE | Made by : JBP Data filename/Run ID: 600mm Secant ULS | Project Merion - Holland Park, LONDON | Date:18-06-2014 Secant Retaining Wall - 600mm dia @ 900mm c/c - (ULS) | Checked : ----------------------------------------------------------------------------Units: kN,m INPUT DATA Program: WALLAP Version 6.05 SOIL PROFILE Stratum Elevation of no. top of stratum 1 23.00 2 22.50 3 14.00 ------------------ Soil types ------------------Active side Passive side 11 Made Ground ULS (D) 11 Made Ground ULS (D) 12 W.L.Clay ULS (U) 12 W.L.Clay ULS (U) 13 L.Clay ULS (U) 13 L.Clay ULS (U) SOIL PROPERTIES -- Soil type -No. Description (Datum elev.) 1 Made Ground SLS (D) 2 W. L. Clay SLS (U) 3 L. Clay S.. ( 14.00 ) 4 W.L.Clay SLS (D) 5 L.Clay SL.. ( 14.00 ) 6 Not defined 7 Not defined 8 Not defined 9 Not defined 10 Not defined 11 Made Ground ULS (D) 12 W.L.Clay ULS (U) 13 L.Clay UL.. ( 14.00 ) 14 W.L.Clay ULS (D) 15 L.Clay UL.. ( 14.00 ) Bulk Young's At rest Consol density Modulus coeff. state. kN/m3 Eh,kN/m2 Ko NC/OC (dEh/dy ) (dKo/dy) ( Nu ) 19.00 10000 0.500 OC (0.200) 20.00 78000 1.000 OC (0.490) 20.00 78000 1.250 OC ( 5526) (0.490) 20.00 60060 1.000 OC (0.200) 20.00 60060 1.250 OC ( 4255) (0.200) 19.00 8334 20.00 20.00 ( 20.00 20.00 ( 0.577 52000 1.000 52000 3684) 40055 1.250 40055 2826) 1.000 1.250 OC (0.200) OC (0.490) OC (0.490) OC (0.200) OC (0.200) Active limit Ka ( Kac ) 0.284 (0.000) 1.000 (2.000) 1.000 (2.000) 0.351 (1.391) 0.351 (1.391) 0.351 (0.000) 1.000 (2.000) 1.000 (2.000) 0.419 (1.528) 0.419 (1.528) Passive limit Cohesion Kp kN/m2 ( Kpc ) ( dc/dy ) 4.369 ( 0.000) 1.000 130.0u ( 2.000) 1.000 130.0u ( 2.000) ( 9.210) 3.253 0.0d ( 4.831) 3.253 5.000d ( 4.831) 3.253 ( 0.000) 1.000 ( 2.000) 1.000 ( 2.000) ( 2.597 ( 4.198) 2.597 ( 4.198) 86.70u 86.70u 6.140) 0.0d 4.160d Additional soil parameters associated with Ka and Kp --- parameters for Ka --- --- parameters for Kp --Soil Wall BackSoil Wall Back------- Soil type ------- friction adhesion fill friction adhesion fill No. Description angle coeff. angle angle coeff. angle 1 Made Ground SLS (D) 30.00 0.666 0.00 30.00 0.500 0.00 2 W. L. Clay SLS (U) 0.00 0.000 0.00 0.00 0.000 0.00 3 L. Clay SLS (U) 0.00 0.000 0.00 0.00 0.000 0.00 4 W.L.Clay SLS (D) 25.00 0.666 0.00 25.00 0.500 0.00 5 L.Clay SLS (D) 25.00 0.666 0.00 25.00 0.500 0.00 6 Not defined 7 Not defined 8 Not defined 9 Not defined 10 Not defined 11 Made Ground ULS (D) 25.00 0.666 0.00 25.00 0.500 0.00 12 W.L.Clay ULS (U) 0.00 0.000 0.00 0.00 0.000 0.00 13 L.Clay ULS (U) 0.00 0.000 0.00 0.00 0.000 0.00 14 W.L.Clay ULS (D) 20.83 0.666 0.00 20.83 0.500 0.00 15 L.Clay ULS (D) 20.83 0.666 0.00 20.83 0.500 0.00 GROUND WATER CONDITIONS Density of water = 10.00 kN/m3 Initial water table elevation Active side 10.00 Passive side 10.00 Automatic water pressure balancing at toe of wall : Water Active side press. ------------------------------profile Point Elev. Piezo Water no. no. elev. press. m m kN/m2 1 1 22.00 22.00 0.0 No Passive side ------------------------------Point Elev. Piezo Water no. elev. press. m m kN/m2 1 13.80 13.80 0.0 2 13.80 22.00 82.0 WALL PROPERTIES Type of structure Elevation of toe of wall Maximum finite element length Youngs modulus of wall E Moment of inertia of wall I E.I Yield Moment of wall STRUTS and ANCHORS Strut/ anchor Strut no. Elev. spacing m 1 22.50 5.00 2 14.25 1.00 3 17.65 1.00 X-section area Youngs of strut modulus sq.m kN/m2 0.014000 2.800E+08 0.250000 1.400E+07 0.250000 1.400E+07 SURCHARGE LOADS Surch Distance Length -arge from parallel no. Elev. wall to wall 1 23.00 1.00(A) 25.00 2 23.00 2.00(A) 25.00 3 23.00 0.00(A) 25.00 4 13.80 -0.00(P) 25.00 Note: A = Active side, = = = = = = = Fully Embedded Wall 11.00 0.60 m 2.8000E+07 kN/m2 7.0686E-03 m4/m run 197921 kN.m2/m run Not defined Inclin Free -ation length (degs) m 15.00 0.00 15.00 0.00 15.00 0.00 Prestress /strut kN 0 0 0 Tension allowed No No No Width Surcharge Equiv. Partial perpend. ----- kN/m2 ----- soil factor/ to wall Near edge Far edge type Category 1.00 5.00 = N/A N/A 6.00 20.00 = N/A N/A 1.00 5.00 = N/A N/A 15.00 82.00 = N/A N/A P = Passive side CONSTRUCTION STAGES Construction Stage description stage no. -------------------------------------------------------1 Apply surcharge no.1 at elevation 23.00 2 Apply surcharge no.2 at elevation 23.00 3 Change EI of wall to 197921 kN.m2/m run Yield moment not defined Reset wall displacements to zero at this stage 4 Excavate to elevation 22.00 on PASSIVE side 5 Install strut or anchor no.1 at elevation 22.50 6 Excavate to elevation 13.30 on PASSIVE side 7 Fill to elevation 13.80 on PASSIVE side with soil type 11 8 Install strut or anchor no.2 at elevation 14.25 9 Install strut or anchor no.3 at elevation 17.65 10 Change EI of wall to 216681 kN.m2/m run From elevation 23.00 to 13.80 Yield moment not defined Allow wall to relax with new modulus value 11 Remove strut or anchor no.1 at elevation 22.50 12 Apply surcharge no.3 at elevation 23.00 13 Change properties of soil type 12 to soil type 14 Ko pressures will not be reset 14 Change properties of soil type 13 to soil type 15 Ko pressures will not be reset 15 Apply surcharge no.4 at elevation 13.80 No analysis at this stage 16 Apply water pressure profile no.1 17 Change EI of wall to 108340 kN.m2/m run From elevation 23.00 to 13.80 18 Yield moment not defined No adjustments to wall displacements Change EI of wall to 98960 kN.m2/m run From elevation 13.80 to 11.00 Yield moment not defined No adjustments to wall displacements FACTORS OF SAFETY and ANALYSIS OPTIONS Stability analysis: Method of analysis - Strength Factor method Factor on soil strength for calculating wall depth = 1.50 Parameters for undrained strata: Minimum equivalent fluid density Maximum depth of water filled tension crack Bending moment and displacement Method - Subgrade reaction Open Tension Crack analysis? Non-linear Modulus Parameter = = 5.00 kN/m3 0.00 m calculation: model using Influence Coefficients - No (L) = 0 m Boundary conditions: Length of wall (normal to plane of analysis) = 1000.00 m Width of excavation on active side of wall Width of excavation on passive side of wall = 20.00 m = 20.00 m Distance to rigid boundary on active side = 20.00 m Distance to rigid boundary on passive side = 20.00 m OUTPUT OPTIONS Stage ------ Stage description ----------- ------- Output options ------no. Displacement Active, Graph. Bending mom. Passive output Shear force pressures 1 Apply surcharge no.1 at elev. 23.00 No No No 2 Apply surcharge no.2 at elev. 23.00 No No No 3 Change EI of wall to 197921kN.m2/m run No No No 4 Excav. to elev. 22.00 on PASSIVE side No No No 5 Install strut no.1 at elev. 22.50 No No No 6 Excav. to elev. 13.30 on PASSIVE side No No No 7 Fill to elev. 13.80 on PASSIVE side Yes No Yes 8 Install strut no.2 at elev. 14.25 No No No 9 Install strut no.3 at elev. 17.65 No No No 10 Change EI of wall to 216681kN.m2/m run No No No 11 Remove strut no.1 at elev. 22.50 No No No 12 Apply surcharge no.3 at elev. 23.00 No No No 13 Change soil type 12 to soil type 14 No No No 14 Change soil type 13 to soil type 15 No No No 15 Apply surcharge no.4 at elev. 13.80 No No No 16 Apply water pressure profile no.1 No No No 17 Change EI of wall to 108340kN.m2/m run No No No 18 Change EI of wall to 98960kN.m2/m run Yes No Yes * Summary output Yes Yes Program WALLAP - Copyright (C) 2012 by DL Borin, distributed by GEOSOLVE 69 Rodenhurst Road, London SW4, UK. Tel: +44 20 8674 7251 | Sheet No. Version 6.05 Revision A38.B55.R43 | Job No. 15614 Licensed from GEOSOLVE | Made by : JBP Data filename/Run ID: 600mm Secant ULS | Project Merion - Holland Park, LONDON | Date:18-06-2014 Secant Retaining Wall - 600mm dia @ 900mm c/c - (ULS) | Checked : ----------------------------------------------------------------------------Units: kN,m Program: WALLAP | Sheet No. Version 6.05 Revision A38.B55.R43 | Job No. 15614 Licensed from GEOSOLVE | Made by : JBP Data filename/Run ID: 600mm Secant ULS | Project Merion - Holland Park, LONDON | Date:18-06-2014 Secant Retaining Wall - 600mm dia @ 900mm c/c - (ULS) | Checked : ----------------------------------------------------------------------------Units: kN,m Stage No. 7 Fill to elevation 13.80 on PASSIVE side with soil type 11 Program: WALLAP STABILITY ANALYSIS of Fully Embedded Wall according to Strength Factor method Factor of safety on soil strength Stage No. 7 --- G.L. --Act. Pass. 23.00 13.80 Strut Elev. 22.50 FoS for toe elev. = 11.00 --------------Factor Moment of equilib. Safety at elev. 1.478 n/a Toe elev. for FoS = 1.500 ------------Toe Wall elev. Penetr -ation *** *** Legend: *** Result not found BENDING MOMENT and DISPLACEMENT ANALYSIS of Fully Embedded Wall Analysis options Length of wall perpendicular to section = 1000.00m Subgrade reaction model - Boussinesq Influence coefficients Soil deformations are elastic until the active or passive limit is reached Open Tension Crack analysis - No Rigid boundaries: Active side 20.00 from wall Passive side 20.00 from wall *** Wall displacements reset to zero at stage 3 Node no. Y coord Nett pressure kN/m2 1 23.00 0.00 2 22.50 3.44 2.50 3 22.00 5.00 4 21.50 7.50 5 21.00 10.00 6 20.40 13.00 7 19.80 16.00 8 19.20 19.00 9 18.60 22.00 10 18.13 24.38 11 17.65 26.75 12 17.23 28.87 13 16.80 31.01 14 16.20 34.26 15 15.60 37.59 16 15.00 40.99 17 14.63 43.15 18 14.25 45.34 19 14.00 46.82 51.16 20 13.80 60.59 21 13.30 83.12 -102.07 22 12.95 -93.12 23 12.60 -82.97 24 12.00 -63.24 25 11.50 -44.87 26 11.00 -24.93 Strut force at elev. Wall disp. m 0.000 0.004 0.004 0.007 0.010 0.013 0.017 0.020 0.023 0.025 0.026 0.028 0.028 0.028 0.028 0.027 0.026 0.025 0.024 0.023 0.023 0.022 0.019 0.019 0.018 0.016 0.013 0.010 0.007 22.50 = Wall rotation rad. -6.67E-03 -6.67E-03 -6.67E-03 -6.61E-03 -6.43E-03 -6.13E-03 -5.64E-03 -5.00E-03 -4.23E-03 -3.35E-03 -2.58E-03 -1.78E-03 -1.03E-03 -2.72E-04 8.03E-04 1.84E-03 2.82E-03 3.38E-03 3.88E-03 4.18E-03 4.18E-03 4.40E-03 4.82E-03 4.82E-03 5.02E-03 5.15E-03 5.26E-03 5.28E-03 5.29E-03 98.72 kN/m Shear force kN/m 0.0 0.9 -97.9 -96.0 -92.9 -88.5 -81.6 -72.9 -62.4 -50.1 -39.1 -26.9 -15.1 -2.4 17.2 38.7 62.3 78.1 94.7 106.2 106.2 117.4 153.3 153.3 119.2 88.3 44.5 17.4 0.0 run = Bending Strut moment forces kN.m/m kN/m -0.0 0.2 98.7 0.2 -47.8 -95.1 -140.4 -191.5 -238.0 -278.6 -312.4 -333.6 -349.3 -358.3 -362.1 -357.7 -341.1 -310.9 -284.6 -252.3 -227.2 -227.2 -204.9 -138.2 -138.2 -90.9 -54.9 -17.1 -2.9 0.0 493.61 kN/strut EI of wall kN.m2/m 197921 197921 197921 197921 197921 197921 197921 197921 197921 197921 197921 197921 197921 197921 197921 197921 197921 197921 197921 197921 197921 197921 197921 197921 197921 --- | Sheet No. Revision A38.B55.R43 | Job No. 15614 Licensed from GEOSOLVE | Made by : JBP Data filename/Run ID: 600mm Secant ULS | Project Merion - Holland Park, LONDON | Date:18-06-2014 Secant Retaining Wall - 600mm dia @ 900mm c/c - (ULS) | Checked : ----------------------------------------------------------------------------Units: kN,m Program: WALLAP Version 6.05 | Sheet No. Version 6.05 Revision A38.B55.R43 | Job No. 15614 Licensed from GEOSOLVE | Made by : JBP Data filename/Run ID: 600mm Secant ULS | Project Merion - Holland Park, LONDON | Date:18-06-2014 Secant Retaining Wall - 600mm dia @ 900mm c/c - (ULS) | Checked : ----------------------------------------------------------------------------Units: kN,m Program: WALLAP | Sheet No. Revision A38.B55.R43 | Job No. 15614 Licensed from GEOSOLVE | Made by : JBP Data filename/Run ID: 600mm Secant ULS | Project Merion - Holland Park, LONDON | Date:18-06-2014 Secant Retaining Wall - 600mm dia @ 900mm c/c - (ULS) | Checked : ----------------------------------------------------------------------------Units: kN,m Stage No. 18 Change EI of wall to 98960 kN.m2/m run From elevation 13.80 to 11.00 Yield moment not defined No adjustments to wall displacements Program: WALLAP Version 6.05 STABILITY ANALYSIS of Fully Embedded Wall according to Strength Factor method Factor of safety on soil strength Stage No. 18 --- G.L. --Act. Pass. 23.00 13.80 Strut Elev. FoS for toe Toe elev. for elev. = 11.00 FoS = 1.500 --------------------------Factor Moment Toe Wall of equilib. elev. Penetr Safety at elev. -ation More than one strut BENDING MOMENT and DISPLACEMENT ANALYSIS of Fully Embedded Wall Analysis options Length of wall perpendicular to section = 1000.00m Subgrade reaction model - Boussinesq Influence coefficients Soil deformations are elastic until the active or passive limit is reached Open Tension Crack analysis - No Rigid boundaries: Active side 20.00 from wall Passive side 20.00 from wall *** Wall displacements reset to zero at stage 3 Node no. Y coord 1 2 23.00 22.50 3 4 5 6 7 8 9 10 11 22.00 21.50 21.00 20.40 19.80 19.20 18.60 18.13 17.65 12 13 14 15 16 17 18 17.23 16.80 16.20 15.60 15.00 14.63 14.25 19 14.00 20 13.80 21 13.30 22 12.95 Nett pressure kN/m2 1.76 5.12 6.11 10.51 17.98 25.81 36.25 46.52 56.56 66.26 73.62 80.61 80.61 87.34 94.14 103.63 113.06 122.42 128.19 133.84 133.84 137.53 131.17 134.03 52.03 41.10 24.83 16.93 Wall disp. m 0.050 0.048 0.048 0.046 0.044 0.042 0.039 0.037 0.035 0.032 0.031 0.030 0.030 0.029 0.028 0.027 0.026 0.025 0.025 0.024 0.024 0.024 0.024 0.024 0.024 0.023 0.023 0.023 Wall rotation rad. 4.18E-03 4.18E-03 4.18E-03 4.18E-03 4.18E-03 4.17E-03 4.14E-03 4.04E-03 3.83E-03 3.47E-03 3.03E-03 2.42E-03 2.42E-03 1.90E-03 1.55E-03 1.32E-03 1.30E-03 1.37E-03 1.41E-03 1.41E-03 1.41E-03 1.41E-03 1.41E-03 1.41E-03 1.41E-03 1.40E-03 1.40E-03 1.41E-03 Shear force kN/m 0.0 1.7 1.7 5.9 13.0 23.9 42.6 67.4 98.3 135.2 168.4 205.0 -258.9 -223.2 -184.6 -125.3 -60.3 10.4 57.4 106.5 -96.0 -62.1 -62.1 -35.6 -35.6 -12.3 -12.3 -5.0 Bending moment kN.m/m 0.0 0.4 0.4 2.7 7.3 16.6 36.2 68.9 118.4 188.2 260.1 348.7 348.7 246.1 159.0 65.1 8.6 -6.7 6.0 36.7 36.7 17.0 17.0 7.2 7.2 -4.4 -4.4 -7.4 Strut forces kN/m EI of wall kN.m2/m 108340 108340 463.9 108340 108340 108340 108340 108340 108340 108340 108340 108340 202.5 108340 108340 108340 108340 108340 108340 108340 108340 98960 98960 98960 Run ID. 600mm Secant ULS | Sheet No. Project Merion - Holland Park, LONDON | Date:18-06-2014 Secant Retaining Wall - 600mm dia @ 900mm c/c - (ULS) | Checked : ----------------------------------------------------------------------------(continued) Stage No.18 Change EI of wall to 98960 kN.m2/m run From elevation 13.80 to 11.00 Yield moment not defined No adjustments to wall displacements Node no. Y coord Nett pressure kN/m2 23 12.60 8.92 24 12.00 5.38 25 11.50 3.75 26 11.00 -28.29 Strut force at elev. Strut force at elev. Wall disp. m 0.022 0.021 0.020 0.020 17.65 = 14.25 = Wall rotation rad. 1.42E-03 1.44E-03 1.44E-03 1.44E-03 463.88 kN/m 202.48 kN/m Shear force kN/m -0.4 3.9 6.1 0.0 run = run = Bending Strut moment forces kN.m/m kN/m -8.2 -2.6 0.4 0.0 463.88 kN/strut 202.48 kN/strut EI of wall kN.m2/m 98960 98960 98960 --- | Sheet No. Revision A38.B55.R43 | Job No. 15614 Licensed from GEOSOLVE | Made by : JBP Data filename/Run ID: 600mm Secant ULS | Project Merion - Holland Park, LONDON | Date:18-06-2014 Secant Retaining Wall - 600mm dia @ 900mm c/c - (ULS) | Checked : ----------------------------------------------------------------------------Units: kN,m Program: WALLAP Version 6.05 | Sheet No. Version 6.05 Revision A38.B55.R43 | Job No. 15614 Licensed from GEOSOLVE | Made by : JBP Data filename/Run ID: 600mm Secant ULS | Project Merion - Holland Park, LONDON | Date:18-06-2014 Secant Retaining Wall - 600mm dia @ 900mm c/c - (ULS) | Checked : ----------------------------------------------------------------------------Units: kN,m Summary of results Program: WALLAP STABILITY ANALYSIS of Fully Embedded Wall according to Strength Factor method Factor of safety on soil strength FoS for toe Toe elev. for elev. = 11.00 FoS = 1.500 --------------------------Stage --- G.L. --Strut Factor Moment Toe Wall No. Act. Pass. Elev. of equilib. elev. Penetr Safety at elev. -ation 1 23.00 23.00 Cant. Conditions not suitable for FoS calc. 2 23.00 23.00 Cant. Conditions not suitable for FoS calc. 3 23.00 23.00 No analysis at this stage 4 23.00 22.00 Cant. 12.307 11.09 21.93 0.07 5 23.00 22.00 No analysis at this stage 6 23.00 13.30 22.50 1.433 n/a *** *** 7 23.00 13.80 22.50 1.478 n/a *** *** 8 23.00 13.80 No analysis at this stage All remaining stages have more than one strut - FoS calculation n/a Legend: *** Result not found | Sheet No. Revision A38.B55.R43 | Job No. 15614 Licensed from GEOSOLVE | Made by : JBP Data filename/Run ID: 600mm Secant ULS | Project Merion - Holland Park, LONDON | Date:18-06-2014 Secant Retaining Wall - 600mm dia @ 900mm c/c - (ULS) | Checked : ----------------------------------------------------------------------------Units: kN,m Summary of results Program: WALLAP Version 6.05 BENDING MOMENT and DISPLACEMENT ANALYSIS of Fully Embedded Wall Analysis options Length of wall perpendicular to section = 1000.00m Subgrade reaction model - Boussinesq Influence coefficients Soil deformations are elastic until the active or passive limit is reached Open Tension Crack analysis - No Rigid boundaries: Active side 20.00 from wall Passive side 20.00 from wall Bending moment, shear force and displacement envelopes Node Y Displacement Bending moment no. coord maximum minimum maximum minimum m m kN.m/m kN.m/m 1 23.00 0.050 0.000 0.0 -0.0 2 22.50 0.048 0.000 0.5 0.0 3 22.00 0.046 0.000 3.5 -47.8 4 21.50 0.044 0.000 9.6 -95.1 5 21.00 0.042 0.000 20.4 -140.4 6 20.40 0.039 0.000 41.1 -191.5 7 19.80 0.037 0.000 72.1 -238.0 8 19.20 0.035 0.000 118.4 -278.6 9 18.60 0.032 0.000 188.2 -312.4 10 18.13 0.031 0.000 260.1 -333.6 11 17.65 0.030 0.000 348.7 -349.3 12 17.23 0.029 0.000 246.1 -358.3 13 16.80 0.028 0.000 159.0 -362.1 14 16.20 0.028 0.000 65.1 -357.7 15 15.60 0.027 0.000 8.6 -341.1 16 15.00 0.026 0.000 0.0 -310.9 17 14.63 0.025 0.000 6.0 -284.6 18 14.25 0.024 0.000 36.7 -252.3 19 14.00 0.024 0.000 17.0 -227.2 20 13.80 0.024 0.000 7.2 -204.9 21 13.30 0.023 0.000 0.0 -138.2 22 12.95 0.023 0.000 0.0 -91.4 23 12.60 0.022 0.000 0.0 -59.1 24 12.00 0.021 0.000 0.0 -25.9 25 11.50 0.020 0.000 0.4 -8.3 26 11.00 0.020 0.000 0.0 -0.0 Shear force maximum minimum kN/m kN/m 0.0 0.0 2.1 -97.9 8.2 -96.0 16.5 -92.9 27.0 -88.5 42.6 -81.6 67.4 -72.9 98.3 -62.4 135.2 -50.1 168.4 -39.1 205.0 -258.9 0.3 -223.2 0.5 -184.6 17.5 -139.0 38.8 -99.4 62.3 -56.2 78.1 -28.2 106.5 -96.0 106.2 -62.1 117.4 -35.6 153.3 -12.3 119.2 -5.0 88.3 -0.4 45.3 -0.0 26.4 -0.0 0.0 -0.0 Run ID. 600mm Secant ULS | Sheet No. Project Merion - Holland Park, LONDON | Date:18-06-2014 Secant Retaining Wall - 600mm dia @ 900mm c/c - (ULS) | Checked : ----------------------------------------------------------------------------Summary of results (continued) Maximum and minimum bending moment and shear force at each stage Stage --------- Bending moment ----------------- Shear force ---------no. maximum elev. minimum elev. maximum elev. minimum elev. kN.m/m kN.m/m kN/m kN/m 1 0.0 13.30 -0.6 19.80 0.2 18.13 -0.4 21.50 2 0.0 22.50 -5.5 17.65 1.2 13.80 -2.0 21.00 3 No calculation at this stage 4 3.2 21.00 -5.3 15.60 3.7 22.00 -2.5 19.20 5 No calculation at this stage 6 0.2 22.50 -359.7 16.80 150.8 13.30 -97.5 22.50 7 0.2 22.50 -362.1 16.80 153.3 13.30 -97.9 22.50 8 No calculation at this stage 9 No calculation at this stage 10 0.2 22.50 -362.1 16.80 153.3 13.30 -97.9 22.50 11 129.5 17.65 -175.9 14.63 100.6 13.30 -170.4 17.65 12 134.5 17.65 -175.8 14.63 100.6 13.30 -173.2 17.65 13 253.4 17.65 -149.8 14.25 137.6 17.65 -219.5 17.65 14 294.8 17.65 -57.4 13.30 151.5 17.65 -198.2 17.65 15 No calculation at this stage 16 348.7 17.65 -8.2 12.60 205.0 17.65 -258.9 17.65 17 No calculation at this stage 18 348.7 17.65 -8.2 12.60 205.0 17.65 -258.9 17.65 Maximum and minimum displacement at each stage Stage -------- Displacement --------Stage description no. maximum elev. minimum elev. ----------------m m 1 0.000 19.80 0.000 23.00 Apply surcharge no.1 at elev. 23.00 2 0.001 15.60 0.000 23.00 Apply surcharge no.2 at elev. 23.00 3 Wall displacements reset to zero Change EI of wall to 197921kN.m2/m run 4 0.002 23.00 0.000 23.00 Excav. to elev. 22.00 on PASSIVE side 5 No calculation at this stage Install strut no.1 at elev. 22.50 6 0.028 16.80 0.000 23.00 Excav. to elev. 13.30 on PASSIVE side 7 0.028 16.80 0.000 23.00 Fill to elev. 13.80 on PASSIVE side 8 No calculation at this stage Install strut no.2 at elev. 14.25 9 No calculation at this stage Install strut no.3 at elev. 17.65 10 0.028 16.80 0.000 23.00 Change EI of wall to 216681kN.m2/m run 11 0.040 23.00 0.000 23.00 Remove strut no.1 at elev. 22.50 12 0.040 23.00 0.000 23.00 Apply surcharge no.3 at elev. 23.00 13 0.049 23.00 0.000 23.00 Change soil type 12 to soil type 14 14 0.048 23.00 0.000 23.00 Change soil type 13 to soil type 15 15 No calculation at this stage Apply surcharge no.4 at elev. 13.80 16 0.050 23.00 0.000 23.00 Apply water pressure profile no.1 17 No calculation at this stage Change EI of wall to 108340kN.m2/m run 18 0.050 23.00 0.000 23.00 Change EI of wall to 98960kN.m2/m run Run ID. 600mm Secant ULS | Sheet No. Project Merion - Holland Park, LONDON | Date:18-06-2014 Secant Retaining Wall - 600mm dia @ 900mm c/c - (ULS) | Checked : ----------------------------------------------------------------------------Summary of results (continued) Strut forces at each stage Stage no. 6 7 10 11 12 13 14 16 18 --- Strut no. 1 --at elev. 22.50 kN/m run kN/strut 98.31 491.56 98.72 493.61 98.72 493.61 ------------------------- (horizontal components) --- Strut no. 2 --at elev. 14.25 kN/m run kN/strut --------0.00 0.00 slack slack slack slack slack slack 72.45 72.45 202.48 202.48 202.48 202.48 --- Strut no. 3 --at elev. 17.65 kN/m run kN/strut --------0.00 0.00 242.18 242.18 246.80 246.80 357.13 357.13 349.73 349.73 463.88 463.88 463.88 463.88 | Sheet No. Version 6.05 Revision A38.B55.R43 | Job No. 15614 Licensed from GEOSOLVE | Made by : JBP Data filename/Run ID: 600mm Secant ULS | Project Merion - Holland Park, LONDON | Date:18-06-2014 Secant Retaining Wall - 600mm dia @ 900mm c/c - (ULS) | Checked : ----------------------------------------------------------------------------Units: kN,m Program: WALLAP PILEDESIGNS Ltd. APPENDIX A PILEDESIGNS Ltd. APPENDIX A Project: Project Merion, Holland Park, LONDON Date: 19/06/2014 Project: Project Merion, Holland Park, LONDON Date: 19/06/2014 Design By: JBP Rev: 0 Design By: JBP Rev: 0 Job No: Design Ref: 15614 Job No: Design Ref: 15614 WALLAP analysis for 600mm secant (SLS), moments and deflection. WALLAP analysis for 750mm secant (ULS), stability and embedment. | Sheet No. Revision A38.B55.R43 | Job No. 15614 Licensed from GEOSOLVE | Made by : JBP Data filename/Run ID: 600mm Secant SLS | Project Merion - Holland Park, LONDON | Date:18-06-2014 Secant Retaining Wall - 600mm dia @ 900mm c/c - (SLS) | Checked : ----------------------------------------------------------------------------Units: kN,m INPUT DATA Program: WALLAP Version 6.05 SOIL PROFILE Stratum Elevation of no. top of stratum 1 23.00 2 22.50 3 14.00 ------------------ Soil types ------------------Active side Passive side 1 Made Ground SLS (D) 1 Made Ground SLS (D) 2 W. L. Clay SLS (U) 2 W. L. Clay SLS (U) 3 L. Clay SLS (U) 3 L. Clay SLS (U) SOIL PROPERTIES -- Soil type -No. Description (Datum elev.) 1 Made Ground SLS (D) 2 W. L. Clay SLS (U) 3 L. Clay S.. ( 14.00 ) 4 W.L.Clay SLS (D) 5 L.Clay SL.. ( 14.00 ) 6 Not defined 7 Not defined 8 Not defined 9 Not defined 10 Not defined 11 Made Ground ULS (D) 12 W.L.Clay ULS (U) 13 L.Clay UL.. ( 14.00 ) 14 W.L.Clay ULS (D) 15 L.Clay UL.. ( 14.00 ) Bulk Young's At rest Consol density Modulus coeff. state. kN/m3 Eh,kN/m2 Ko NC/OC (dEh/dy ) (dKo/dy) ( Nu ) 19.00 10000 0.500 OC (0.200) 20.00 78000 1.000 OC (0.490) 20.00 78000 1.250 OC ( 5526) (0.490) 20.00 60060 1.000 OC (0.200) 20.00 60060 1.250 OC ( 4255) (0.200) 19.00 8334 20.00 20.00 ( 20.00 20.00 ( 0.577 52000 1.000 52000 3684) 40055 1.250 40055 2826) 1.000 1.250 OC (0.200) OC (0.490) OC (0.490) OC (0.200) OC (0.200) Active limit Ka ( Kac ) 0.284 (0.000) 1.000 (2.000) 1.000 (2.000) 0.351 (1.391) 0.351 (1.391) 0.351 (0.000) 1.000 (2.000) 1.000 (2.000) 0.419 (1.528) 0.419 (1.528) Passive limit Cohesion Kp kN/m2 ( Kpc ) ( dc/dy ) 4.369 ( 0.000) 1.000 130.0u ( 2.000) 1.000 130.0u ( 2.000) ( 9.210) 3.253 0.0d ( 4.831) 3.253 5.000d ( 4.831) 3.253 ( 0.000) 1.000 ( 2.000) 1.000 ( 2.000) ( 2.597 ( 4.198) 2.597 ( 4.198) 86.70u 86.70u 6.140) 0.0d 4.160d Additional soil parameters associated with Ka and Kp --- parameters for Ka --- --- parameters for Kp --Soil Wall BackSoil Wall Back------- Soil type ------- friction adhesion fill friction adhesion fill No. Description angle coeff. angle angle coeff. angle 1 Made Ground SLS (D) 30.00 0.666 0.00 30.00 0.500 0.00 2 W. L. Clay SLS (U) 0.00 0.000 0.00 0.00 0.000 0.00 3 L. Clay SLS (U) 0.00 0.000 0.00 0.00 0.000 0.00 4 W.L.Clay SLS (D) 25.00 0.666 0.00 25.00 0.500 0.00 5 L.Clay SLS (D) 25.00 0.666 0.00 25.00 0.500 0.00 6 Not defined 7 Not defined 8 Not defined 9 Not defined 10 Not defined 11 Made Ground ULS (D) 25.00 0.666 0.00 25.00 0.500 0.00 12 W.L.Clay ULS (U) 0.00 0.000 0.00 0.00 0.000 0.00 13 L.Clay ULS (U) 0.00 0.000 0.00 0.00 0.000 0.00 14 W.L.Clay ULS (D) 20.83 0.666 0.00 20.83 0.500 0.00 15 L.Clay ULS (D) 20.83 0.666 0.00 20.83 0.500 0.00 GROUND WATER CONDITIONS Density of water = 10.00 kN/m3 Initial water table elevation Active side 10.00 Passive side 10.00 Automatic water pressure balancing at toe of wall : Water Active side press. ------------------------------profile Point Elev. Piezo Water no. no. elev. press. m m kN/m2 1 1 22.00 22.00 0.0 No Passive side ------------------------------Point Elev. Piezo Water no. elev. press. m m kN/m2 1 13.80 13.80 0.0 2 13.80 22.00 82.0 WALL PROPERTIES Type of structure Elevation of toe of wall Maximum finite element length Youngs modulus of wall E Moment of inertia of wall I E.I Yield Moment of wall STRUTS and ANCHORS Strut/ anchor Strut no. Elev. spacing m 1 22.50 5.00 2 14.25 1.00 3 17.65 1.00 X-section area Youngs of strut modulus sq.m kN/m2 0.014000 2.800E+08 0.250000 1.400E+07 0.250000 1.400E+07 SURCHARGE LOADS Surch Distance Length -arge from parallel no. Elev. wall to wall 1 23.00 1.00(A) 25.00 2 23.00 2.00(A) 25.00 3 23.00 0.00(A) 25.00 4 13.80 -0.00(P) 25.00 Note: A = Active side, = = = = = = = Fully Embedded Wall 11.00 0.60 m 2.8000E+07 kN/m2 7.0686E-03 m4/m run 197921 kN.m2/m run Not defined Inclin Free -ation length (degs) m 15.00 0.00 15.00 0.00 15.00 0.00 Prestress /strut kN 0 0 0 Tension allowed No No No Width Surcharge Equiv. Partial perpend. ----- kN/m2 ----- soil factor/ to wall Near edge Far edge type Category 1.00 5.00 = N/A N/A 6.00 20.00 = N/A N/A 1.00 5.00 = N/A N/A 15.00 82.00 = N/A N/A P = Passive side CONSTRUCTION STAGES Construction Stage description stage no. -------------------------------------------------------1 Apply surcharge no.1 at elevation 23.00 2 Apply surcharge no.2 at elevation 23.00 3 Change EI of wall to 197921 kN.m2/m run Yield moment not defined Reset wall displacements to zero at this stage 4 Excavate to elevation 22.00 on PASSIVE side 5 Install strut or anchor no.1 at elevation 22.50 6 Excavate to elevation 13.80 on PASSIVE side 7 Install strut or anchor no.2 at elevation 14.25 8 Install strut or anchor no.3 at elevation 17.65 9 Change EI of wall to 216681 kN.m2/m run From elevation 23.00 to 13.80 Yield moment not defined Allow wall to relax with new modulus value 10 Remove strut or anchor no.1 at elevation 22.50 11 Apply surcharge no.3 at elevation 23.00 12 Change properties of soil type 2 to soil type 4 Ko pressures will not be reset 13 Change properties of soil type 3 to soil type 5 Ko pressures will not be reset 14 Apply surcharge no.4 at elevation 13.80 No analysis at this stage 15 Apply water pressure profile no.1 16 Change EI of wall to 108340 kN.m2/m run From elevation 23.00 to 13.80 Yield moment not defined 17 No adjustments to wall displacements Change EI of wall to 98960 kN.m2/m run From elevation 13.80 to 11.00 Yield moment not defined No adjustments to wall displacements FACTORS OF SAFETY and ANALYSIS OPTIONS Stability analysis: Method of analysis - Strength Factor method Factor on soil strength for calculating wall depth = 1.50 Parameters for undrained strata: Minimum equivalent fluid density Maximum depth of water filled tension crack Bending moment and displacement Method - Subgrade reaction Open Tension Crack analysis? Non-linear Modulus Parameter = = 5.00 kN/m3 0.00 m calculation: model using Influence Coefficients - No (L) = 0 m Boundary conditions: Length of wall (normal to plane of analysis) = 1000.00 m Width of excavation on active side of wall Width of excavation on passive side of wall = 20.00 m = 20.00 m Distance to rigid boundary on active side = 20.00 m Distance to rigid boundary on passive side = 20.00 m OUTPUT OPTIONS Stage ------ Stage description ----------- ------- Output options ------no. Displacement Active, Graph. Bending mom. Passive output Shear force pressures 1 Apply surcharge no.1 at elev. 23.00 No No No 2 Apply surcharge no.2 at elev. 23.00 No No No 3 Change EI of wall to 197921kN.m2/m run No No No 4 Excav. to elev. 22.00 on PASSIVE side No No No 5 Install strut no.1 at elev. 22.50 No No No 6 Excav. to elev. 13.80 on PASSIVE side Yes No Yes 7 Install strut no.2 at elev. 14.25 No No No 8 Install strut no.3 at elev. 17.65 No No No 9 Change EI of wall to 216681kN.m2/m run No No No 10 Remove strut no.1 at elev. 22.50 No No No 11 Apply surcharge no.3 at elev. 23.00 No No No 12 Change soil type 2 to soil type 4 No No No 13 Change soil type 3 to soil type 5 No No No 14 Apply surcharge no.4 at elev. 13.80 No No No 15 Apply water pressure profile no.1 No No No 16 Change EI of wall to 108340kN.m2/m run No No No 17 Change EI of wall to 98960kN.m2/m run Yes No Yes * Summary output Yes Yes Program WALLAP - Copyright (C) 2012 by DL Borin, distributed by GEOSOLVE 69 Rodenhurst Road, London SW4, UK. Tel: +44 20 8674 7251 | Sheet No. Revision A38.B55.R43 | Job No. 15614 Licensed from GEOSOLVE | Made by : JBP Data filename/Run ID: 600mm Secant SLS | Project Merion - Holland Park, LONDON | Date:18-06-2014 Secant Retaining Wall - 600mm dia @ 900mm c/c - (SLS) | Checked : ----------------------------------------------------------------------------Units: kN,m Program: WALLAP Version 6.05 | Sheet No. Version 6.05 Revision A38.B55.R43 | Job No. 15614 Licensed from GEOSOLVE | Made by : JBP Data filename/Run ID: 600mm Secant SLS | Project Merion - Holland Park, LONDON | Date:18-06-2014 Secant Retaining Wall - 600mm dia @ 900mm c/c - (SLS) | Checked : ----------------------------------------------------------------------------Units: kN,m Stage No. 6 Excavate to elevation 13.80 on PASSIVE side Program: WALLAP STABILITY ANALYSIS of Fully Embedded Wall according to Strength Factor method Factor of safety on soil strength Stage No. 6 --- G.L. --Act. Pass. 23.00 13.80 Strut Elev. 22.50 FoS for toe elev. = 11.00 --------------Factor Moment of equilib. Safety at elev. 2.348 n/a Toe elev. for FoS = 1.500 ------------Toe Wall elev. Penetr -ation 12.90 0.90 BENDING MOMENT and DISPLACEMENT ANALYSIS of Fully Embedded Wall Analysis options Length of wall perpendicular to section = 1000.00m Subgrade reaction model - Boussinesq Influence coefficients Soil deformations are elastic until the active or passive limit is reached Open Tension Crack analysis - No Rigid boundaries: Active side 20.00 from wall Passive side 20.00 from wall *** Wall displacements reset to zero at stage 3 Node no. Y coord Nett pressure kN/m2 1 23.00 0.00 2 22.50 2.78 2.50 3 22.00 5.00 4 21.50 7.50 5 21.00 10.00 6 20.40 13.00 7 19.80 16.00 8 19.20 19.00 9 18.60 22.00 10 18.13 24.38 11 17.65 26.75 12 17.23 28.87 13 16.80 31.00 14 16.20 34.00 15 15.60 37.00 16 15.00 40.00 17 14.63 41.87 18 14.25 44.27 19 14.00 58.67 103.55 20 13.80 114.47 -149.21 21 13.20 -138.02 22 12.60 -98.45 23 12.00 -21.76 24 11.50 44.13 25 11.00 113.24 Strut force at elev. Wall disp. m 0.001 0.003 0.003 0.005 0.007 0.009 0.011 0.012 0.014 0.015 0.016 0.016 0.016 0.016 0.015 0.014 0.013 0.012 0.011 0.010 0.010 0.010 0.010 0.008 0.006 0.004 0.003 0.002 22.50 = Wall rotation rad. -4.09E-03 -4.09E-03 -4.09E-03 -4.04E-03 -3.90E-03 -3.67E-03 -3.29E-03 -2.79E-03 -2.21E-03 -1.55E-03 -9.91E-04 -4.09E-04 1.18E-04 6.41E-04 1.34E-03 1.98E-03 2.51E-03 2.78E-03 2.96E-03 3.05E-03 3.05E-03 3.08E-03 3.08E-03 3.06E-03 2.90E-03 2.75E-03 2.68E-03 2.66E-03 78.00 kN/m Shear force kN/m 0.0 0.7 -77.3 -75.4 -72.3 -67.9 -61.0 -52.3 -41.8 -29.5 -18.5 -6.4 5.4 18.2 37.7 59.0 82.1 97.4 113.6 126.4 126.4 148.2 148.2 62.1 -8.9 -44.9 -39.3 0.0 run = Bending Strut moment forces kN.m/m kN/m 0.0 0.2 78.0 0.2 -37.6 -74.5 -109.7 -148.4 -182.5 -210.8 -232.3 -243.7 -249.7 -249.9 -244.9 -228.3 -199.4 -157.2 -123.5 -81.1 -51.2 -51.2 -23.8 -23.8 37.8 62.4 39.4 14.2 -0.0 390.01 kN/strut EI of wall kN.m2/m 197921 197921 197921 197921 197921 197921 197921 197921 197921 197921 197921 197921 197921 197921 197921 197921 197921 197921 197921 197921 197921 197921 197921 197921 --- | Sheet No. Revision A38.B55.R43 | Job No. 15614 Licensed from GEOSOLVE | Made by : JBP Data filename/Run ID: 600mm Secant SLS | Project Merion - Holland Park, LONDON | Date:18-06-2014 Secant Retaining Wall - 600mm dia @ 900mm c/c - (SLS) | Checked : ----------------------------------------------------------------------------Units: kN,m Program: WALLAP Version 6.05 | Sheet No. Version 6.05 Revision A38.B55.R43 | Job No. 15614 Licensed from GEOSOLVE | Made by : JBP Data filename/Run ID: 600mm Secant SLS | Project Merion - Holland Park, LONDON | Date:18-06-2014 Secant Retaining Wall - 600mm dia @ 900mm c/c - (SLS) | Checked : ----------------------------------------------------------------------------Units: kN,m Program: WALLAP | Sheet No. Revision A38.B55.R43 | Job No. 15614 Licensed from GEOSOLVE | Made by : JBP Data filename/Run ID: 600mm Secant SLS | Project Merion - Holland Park, LONDON | Date:18-06-2014 Secant Retaining Wall - 600mm dia @ 900mm c/c - (SLS) | Checked : ----------------------------------------------------------------------------Units: kN,m Stage No. 17 Change EI of wall to 98960 kN.m2/m run From elevation 13.80 to 11.00 Yield moment not defined No adjustments to wall displacements Program: WALLAP Version 6.05 STABILITY ANALYSIS of Fully Embedded Wall according to Strength Factor method Factor of safety on soil strength Stage No. 17 --- G.L. --Act. Pass. 23.00 13.80 Strut Elev. FoS for toe Toe elev. for elev. = 11.00 FoS = 1.500 --------------------------Factor Moment Toe Wall of equilib. elev. Penetr Safety at elev. -ation More than one strut BENDING MOMENT and DISPLACEMENT ANALYSIS of Fully Embedded Wall Analysis options Length of wall perpendicular to section = 1000.00m Subgrade reaction model - Boussinesq Influence coefficients Soil deformations are elastic until the active or passive limit is reached Open Tension Crack analysis - No Rigid boundaries: Active side 20.00 from wall Passive side 20.00 from wall *** Wall displacements reset to zero at stage 3 Node no. Y coord 1 2 23.00 22.50 3 4 5 6 7 8 9 10 11 22.00 21.50 21.00 20.40 19.80 19.20 18.60 18.13 17.65 12 13 14 15 16 17 18 17.23 16.80 16.20 15.60 15.00 14.63 14.25 19 14.00 20 13.80 21 22 23 13.20 12.60 12.00 Nett pressure kN/m2 1.42 4.14 5.13 8.82 15.90 23.04 31.58 40.05 48.43 57.76 65.26 72.31 72.31 78.34 84.72 97.08 104.33 110.37 115.36 120.11 120.11 123.10 154.87 161.04 54.88 47.38 39.89 32.88 Wall disp. m 0.039 0.037 0.037 0.035 0.033 0.031 0.028 0.026 0.023 0.021 0.019 0.018 0.018 0.017 0.016 0.015 0.014 0.013 0.013 0.012 0.012 0.012 0.012 0.012 0.012 0.012 0.011 0.011 Wall rotation rad. 4.30E-03 4.30E-03 4.30E-03 4.30E-03 4.31E-03 4.30E-03 4.27E-03 4.18E-03 3.99E-03 3.67E-03 3.28E-03 2.75E-03 2.75E-03 2.26E-03 1.92E-03 1.60E-03 1.39E-03 1.20E-03 1.04E-03 8.16E-04 8.16E-04 6.54E-04 6.54E-04 5.50E-04 5.50E-04 3.10E-04 1.80E-04 1.16E-04 Shear force kN/m 0.0 1.4 1.4 4.9 11.1 20.8 37.2 58.7 85.2 117.1 146.3 179.0 -194.3 -162.3 -127.6 -73.1 -12.7 51.7 94.1 138.2 -162.2 -131.8 -131.8 -100.2 -100.2 -69.5 -43.3 -21.5 Bending moment kN.m/m 0.0 0.3 0.3 2.3 6.2 14.0 31.1 59.7 102.7 163.4 225.7 302.8 302.8 227.0 164.9 103.9 77.9 88.9 116.3 162.8 162.8 126.0 126.0 102.8 102.8 53.0 31.4 9.7 Strut forces kN/m EI of wall kN.m2/m 108340 108340 373.2 108340 108340 108340 108340 108340 108340 108340 108340 108340 300.4 108340 108340 108340 108340 108340 108340 108340 108340 98960 98960 98960 98960 Run ID. 600mm Secant SLS | Sheet No. Project Merion - Holland Park, LONDON | Date:18-06-2014 Secant Retaining Wall - 600mm dia @ 900mm c/c - (SLS) | Checked : ----------------------------------------------------------------------------(continued) Stage No.17 Change EI of wall to 98960 kN.m2/m run From elevation 13.80 to 11.00 Yield moment not defined No adjustments to wall displacements Node no. Y coord Nett pressure kN/m2 24 11.50 25.85 25 11.00 1.33 Strut force at elev. Strut force at elev. Wall disp. m 0.011 0.011 17.65 = 14.25 = Wall rotation rad. 1.02E-04 1.00E-04 373.24 kN/m 300.38 kN/m Shear force kN/m -6.8 0.0 run = run = Bending Strut moment forces kN.m/m kN/m 1.3 -0.0 373.24 kN/strut 300.38 kN/strut EI of wall kN.m2/m 98960 --- | Sheet No. Version 6.05 Revision A38.B55.R43 | Job No. 15614 Licensed from GEOSOLVE | Made by : JBP Data filename/Run ID: 600mm Secant SLS | Project Merion - Holland Park, LONDON | Date:18-06-2014 Secant Retaining Wall - 600mm dia @ 900mm c/c - (SLS) | Checked : ----------------------------------------------------------------------------Units: kN,m Program: WALLAP | Sheet No. Version 6.05 Revision A38.B55.R43 | Job No. 15614 Licensed from GEOSOLVE | Made by : JBP Data filename/Run ID: 600mm Secant SLS | Project Merion - Holland Park, LONDON | Date:18-06-2014 Secant Retaining Wall - 600mm dia @ 900mm c/c - (SLS) | Checked : ----------------------------------------------------------------------------Units: kN,m Summary of results Program: WALLAP STABILITY ANALYSIS of Fully Embedded Wall according to Strength Factor method Factor of safety on soil strength FoS for toe Toe elev. for elev. = 11.00 FoS = 1.500 --------------------------Stage --- G.L. --Strut Factor Moment Toe Wall No. Act. Pass. Elev. of equilib. elev. Penetr Safety at elev. -ation 1 23.00 23.00 Cant. Conditions not suitable for FoS calc. 2 23.00 23.00 Cant. Conditions not suitable for FoS calc. 3 23.00 23.00 No analysis at this stage 4 23.00 22.00 Cant. 18.449 11.09 21.96 0.04 5 23.00 22.00 No analysis at this stage 6 23.00 13.80 22.50 2.348 n/a 12.90 0.90 7 23.00 13.80 No analysis at this stage All remaining stages have more than one strut - FoS calculation n/a | Sheet No. Revision A38.B55.R43 | Job No. 15614 Licensed from GEOSOLVE | Made by : JBP Data filename/Run ID: 600mm Secant SLS | Project Merion - Holland Park, LONDON | Date:18-06-2014 Secant Retaining Wall - 600mm dia @ 900mm c/c - (SLS) | Checked : ----------------------------------------------------------------------------Units: kN,m Summary of results Program: WALLAP Version 6.05 BENDING MOMENT and DISPLACEMENT ANALYSIS of Fully Embedded Wall Analysis options Length of wall perpendicular to section = 1000.00m Subgrade reaction model - Boussinesq Influence coefficients Soil deformations are elastic until the active or passive limit is reached Open Tension Crack analysis - No Rigid boundaries: Active side 20.00 from wall Passive side 20.00 from wall Bending moment, shear force and displacement envelopes Node Y Displacement Bending moment no. coord maximum minimum maximum minimum m m kN.m/m kN.m/m 1 23.00 0.039 0.000 0.0 0.0 2 22.50 0.037 0.000 0.4 0.0 3 22.00 0.035 0.000 2.7 -37.6 4 21.50 0.033 0.000 7.3 -74.5 5 21.00 0.031 0.000 15.7 -109.7 6 20.40 0.028 0.000 32.0 -148.4 7 19.80 0.026 0.000 59.7 -182.5 8 19.20 0.023 0.000 102.7 -210.8 9 18.60 0.021 0.000 163.4 -232.3 10 18.13 0.019 0.000 225.7 -243.7 11 17.65 0.018 0.000 302.8 -249.7 12 17.23 0.017 0.000 227.0 -249.9 13 16.80 0.016 0.000 164.9 -244.9 14 16.20 0.015 0.000 103.9 -228.3 15 15.60 0.014 0.000 77.9 -199.4 16 15.00 0.013 0.000 88.9 -157.2 17 14.63 0.013 0.000 116.3 -123.5 18 14.25 0.012 0.000 162.8 -81.1 19 14.00 0.012 0.000 126.0 -51.2 20 13.80 0.012 0.000 102.8 -23.8 21 13.20 0.012 0.000 53.0 -9.6 22 12.60 0.011 0.000 62.4 -7.6 23 12.00 0.011 0.000 39.4 -7.8 24 11.50 0.011 0.000 14.2 -3.4 25 11.00 0.011 0.000 0.0 -0.0 Shear force maximum minimum kN/m kN/m 0.0 0.0 1.6 -77.3 6.1 -75.4 12.6 -72.3 21.0 -67.9 37.2 -61.0 58.7 -52.3 85.2 -41.8 117.1 -29.5 146.3 -18.5 179.0 -194.3 5.4 -162.3 18.2 -127.6 37.7 -94.5 59.0 -56.2 82.1 -15.0 97.4 0.0 138.2 -162.2 126.4 -131.8 148.2 -100.2 62.1 -69.5 1.5 -43.3 10.2 -44.9 12.0 -39.3 0.0 -0.0 Run ID. 600mm Secant SLS | Sheet No. Project Merion - Holland Park, LONDON | Date:18-06-2014 Secant Retaining Wall - 600mm dia @ 900mm c/c - (SLS) | Checked : ----------------------------------------------------------------------------Summary of results (continued) Maximum and minimum bending moment and shear force at each stage Stage --------- Bending moment ----------------- Shear force ---------no. maximum elev. minimum elev. maximum elev. minimum elev. kN.m/m kN.m/m kN/m kN/m 1 0.0 13.80 -0.5 19.80 0.2 18.13 -0.3 21.50 2 0.0 22.50 -4.0 18.13 0.9 13.80 -1.6 21.00 3 No calculation at this stage 4 3.1 21.00 -4.1 15.60 3.6 22.00 -2.1 19.20 5 No calculation at this stage 6 62.4 12.60 -249.9 17.23 148.2 13.80 -77.3 22.50 7 No calculation at this stage 8 No calculation at this stage 9 62.4 12.60 -249.9 17.23 148.2 13.80 -77.3 22.50 10 128.6 17.65 -70.1 15.00 95.6 13.80 -131.2 17.65 11 132.6 17.65 -70.0 15.00 95.6 13.80 -133.6 17.65 12 212.5 17.65 -47.4 14.63 115.5 17.65 -164.6 17.65 13 238.8 17.65 -9.6 13.20 125.1 17.65 -138.5 17.65 14 No calculation at this stage 15 302.8 17.65 -0.0 11.00 179.0 17.65 -194.3 17.65 16 No calculation at this stage 17 302.8 17.65 -0.0 11.00 179.0 17.65 -194.3 17.65 Maximum and minimum displacement at each stage Stage -------- Displacement --------Stage description no. maximum elev. minimum elev. ----------------m m 1 0.000 19.80 0.000 23.00 Apply surcharge no.1 at elev. 23.00 2 0.000 16.20 0.000 23.00 Apply surcharge no.2 at elev. 23.00 3 Wall displacements reset to zero Change EI of wall to 197921kN.m2/m run 4 0.001 23.00 0.000 23.00 Excav. to elev. 22.00 on PASSIVE side 5 No calculation at this stage Install strut no.1 at elev. 22.50 6 0.016 17.23 0.000 23.00 Excav. to elev. 13.80 on PASSIVE side 7 No calculation at this stage Install strut no.2 at elev. 14.25 8 No calculation at this stage Install strut no.3 at elev. 17.65 9 0.016 17.23 0.000 23.00 Change EI of wall to 216681kN.m2/m run 10 0.031 23.00 0.000 23.00 Remove strut no.1 at elev. 22.50 11 0.031 23.00 0.000 23.00 Apply surcharge no.3 at elev. 23.00 12 0.037 23.00 0.000 23.00 Change soil type 2 to soil type 4 13 0.036 23.00 0.000 23.00 Change soil type 3 to soil type 5 14 No calculation at this stage Apply surcharge no.4 at elev. 13.80 15 0.039 23.00 0.000 23.00 Apply water pressure profile no.1 16 No calculation at this stage Change EI of wall to 108340kN.m2/m run 17 0.039 23.00 0.000 23.00 Change EI of wall to 98960kN.m2/m run Run ID. 600mm Secant SLS | Sheet No. Project Merion - Holland Park, LONDON | Date:18-06-2014 Secant Retaining Wall - 600mm dia @ 900mm c/c - (SLS) | Checked : ----------------------------------------------------------------------------Summary of results (continued) Strut forces at each stage Stage no. 6 9 10 11 12 13 15 17 --- Strut no. 1 --at elev. 22.50 kN/m run kN/strut 78.00 390.01 78.00 390.01 ------------------------- (horizontal components) --- Strut no. 2 --at elev. 14.25 kN/m run kN/strut ----0.00 0.00 slack slack slack slack slack slack 155.66 155.66 300.38 300.38 300.38 300.38 --- Strut no. 3 --at elev. 17.65 kN/m run kN/strut ----0.00 0.00 202.81 202.81 206.58 206.58 280.09 280.09 263.61 263.61 373.24 373.24 373.24 373.24 | Sheet No. Version 6.05 Revision A38.B55.R43 | Job No. 15614 Licensed from GEOSOLVE | Made by : JBP Data filename/Run ID: 600mm Secant SLS | Project Merion - Holland Park, LONDON | Date:18-06-2014 Secant Retaining Wall - 600mm dia @ 900mm c/c - (SLS) | Checked : ----------------------------------------------------------------------------Units: kN,m Program: WALLAP | Sheet No. Revision A38.B55.R43 | Job No. 15614 Licensed from GEOSOLVE | Made by : JBP Data filename/Run ID: 750mm Secant ULS | Project Merion - Holland Park, LONDON | Date:18-06-2014 Secant Retaining Wall - 750mm dia @ 1100mm c/c - (ULS) | Checked : ----------------------------------------------------------------------------Units: kN,m INPUT DATA Program: WALLAP Version 6.05 SOIL PROFILE Stratum Elevation of no. top of stratum 1 28.00 2 27.50 3 14.00 ------------------ Soil types ------------------Active side Passive side 11 Made Ground ULS (D) 11 Made Ground ULS (D) 12 W.L.Clay ULS (U) 12 W.L.Clay ULS (U) 13 L.Clay ULS (U) 13 L.Clay ULS (U) SOIL PROPERTIES -- Soil type -No. Description (Datum elev.) 1 Made Ground SLS (D) 2 W. L. Clay SLS (U) 3 L. Clay S.. ( 14.00 ) 4 W.L.Clay SLS (D) 5 L.Clay SL.. ( 14.00 ) 6 Not defined 7 Not defined 8 Not defined 9 Not defined 10 Not defined 11 Made Ground ULS (D) 12 W.L.Clay ULS (U) 13 L.Clay UL.. ( 14.00 ) 14 W.L.Clay ULS (D) 15 L.Clay UL.. ( 14.00 ) Bulk Young's At rest Consol density Modulus coeff. state. kN/m3 Eh,kN/m2 Ko NC/OC (dEh/dy ) (dKo/dy) ( Nu ) 19.00 10000 0.500 OC (0.200) 20.00 78000 1.000 OC (0.490) 20.00 78000 1.250 OC ( 5526) (0.490) 20.00 60060 1.000 OC (0.200) 20.00 60060 1.250 OC ( 4255) (0.200) 19.00 8334 20.00 52000 20.00 ( 20.00 20.00 ( 52000 3684) 40055 40055 2826) 0.577 1.000 1.250 1.000 1.250 OC (0.200) OC (0.490) OC (0.490) OC (0.200) OC (0.200) Active limit Ka ( Kac ) 0.284 (0.000) 1.000 (2.000) 1.000 (2.000) 0.351 (1.391) 0.351 (1.391) 0.351 (0.000) 1.000 (2.000) 1.000 (2.000) 0.419 (1.528) 0.419 (1.528) Passive limit Cohesion Kp kN/m2 ( Kpc ) ( dc/dy ) 4.369 ( 0.000) 1.000 130.0u ( 2.000) 1.000 130.0u ( 2.000) ( 9.210) 3.253 0.0d ( 4.831) 3.253 5.000d ( 4.831) ( ( ( ( ( 3.253 0.000) 1.000 2.000) 1.000 2.000) ( 2.597 4.198) 2.597 4.198) 86.70u 86.70u 6.140) 0.0d GROUND WATER CONDITIONS Density of water = 10.00 kN/m3 Initial water table elevation Additional soil parameters associated with Ka and Kp --- parameters for Ka --- --- parameters for Kp --Soil Wall BackSoil Wall Back------- Soil type ------- friction adhesion fill friction adhesion fill No. Description angle coeff. angle angle coeff. angle 1 Made Ground SLS (D) 30.00 0.666 0.00 30.00 0.500 0.00 2 W. L. Clay SLS (U) 0.00 0.000 0.00 0.00 0.000 0.00 3 L. Clay SLS (U) 0.00 0.000 0.00 0.00 0.000 0.00 4 W.L.Clay SLS (D) 25.00 0.666 0.00 25.00 0.500 0.00 5 L.Clay SLS (D) 25.00 0.666 0.00 25.00 0.500 0.00 6 Not defined 7 Not defined 8 Not defined 9 Not defined 10 Not defined 11 Made Ground ULS (D) 25.00 0.666 0.00 25.00 0.500 0.00 12 W.L.Clay ULS (U) 0.00 0.000 0.00 0.00 0.000 0.00 13 L.Clay ULS (U) 0.00 0.000 0.00 0.00 0.000 0.00 14 W.L.Clay ULS (D) 20.83 0.666 0.00 20.83 0.500 0.00 15 L.Clay ULS (D) 20.83 0.666 0.00 20.83 0.500 0.00 Passive side 10.00 Automatic water pressure balancing at toe of wall : Water Active side press. ------------------------------profile Point Elev. Piezo Water no. no. elev. press. m m kN/m2 1 1 27.00 27.00 0.0 No Passive side ------------------------------Point Elev. Piezo Water no. elev. press. m m kN/m2 1 13.80 13.80 0.0 2 13.80 27.00 132.0 WALL PROPERTIES Type of structure Elevation of toe of wall Maximum finite element length Youngs modulus of wall E Moment of inertia of wall I E.I Yield Moment of wall STRUTS and ANCHORS Strut/ anchor Strut no. Elev. spacing m 1 27.50 5.00 2 21.00 5.00 3 14.25 1.00 4 17.65 1.00 5 21.19 1.00 6 25.91 1.00 X-section area of strut sq.m 0.014000 0.014000 0.250000 0.250000 0.250000 0.250000 SURCHARGE LOADS Surch Distance Length -arge from parallel no. Elev. wall to wall 1 28.00 1.00(A) 25.00 2 28.00 0.00(A) 25.00 3 13.80 -0.00(P) 25.00 Note: A = Active side, 4.160d Active side 10.00 Youngs modulus kN/m2 2.800E+08 2.800E+08 1.400E+07 1.400E+07 1.400E+07 1.400E+07 = = = = = = = Fully Embedded Wall 10.00 1.00 m 2.8000E+07 kN/m2 0.014120 m4/m run 395349 kN.m2/m run Not defined Inclin Free -ation length (degs) m 15.00 0.00 15.00 0.00 15.00 0.00 15.00 0.00 15.00 0.00 15.00 0.00 Prestress /strut kN 0 0 0 0 0 0 Tension allowed No No No No No No Width Surcharge Equiv. Partial perpend. ----- kN/m2 ----- soil factor/ to wall Near edge Far edge type Category 15.00 5.00 = N/A N/A 1.00 5.00 = N/A N/A 15.00 132.00 = N/A N/A P = Passive side CONSTRUCTION STAGES Construction Stage description stage no. -------------------------------------------------------1 Apply surcharge no.1 at elevation 28.00 2 Change EI of wall to 395349 kN.m2/m run Yield moment not defined Reset wall displacements to zero at this stage 3 Excavate to elevation 27.00 on PASSIVE side 4 Install strut or anchor no.1 at elevation 27.50 5 Excavate to elevation 20.00 on PASSIVE side 6 Install strut or anchor no.2 at elevation 21.00 7 Excavate to elevation 13.30 on PASSIVE side 8 Fill to elevation 13.80 on PASSIVE side with soil type 11 9 Install strut or anchor no.3 at elevation 14.25 10 Install strut or anchor no.4 at elevation 17.65 11 Remove strut or anchor no.2 at elevation 21.00 12 Install strut or anchor no.5 at elevation 21.19 13 Remove strut or anchor no.1 at elevation 27.50 14 Install strut or anchor no.6 at elevation 25.91 15 Change EI of wall to 458349 kN.m2/m run From elevation 28.00 to 13.80 Yield moment not defined Allow wall to relax with new modulus value 16 Apply surcharge no.2 at elevation 28.00 17 Change properties of soil type 12 to soil type 14 Ko pressures will not be reset 18 Change properties of soil type 13 to soil type 15 Ko pressures will not be reset 19 Apply surcharge no.3 at elevation 13.80 No analysis at this stage 20 Apply water pressure profile no.1 21 Change EI of wall to 229174 kN.m2/m run From elevation 28.00 to 13.80 Yield moment not defined No adjustments to wall displacements 22 Change EI of wall to 197674 kN.m2/m run From elevation 13.80 to 11.00 Yield moment not defined No adjustments to wall displacements FACTORS OF SAFETY and ANALYSIS OPTIONS Stability analysis: Method of analysis - Strength Factor method Factor on soil strength for calculating wall depth = 1.50 Parameters for undrained strata: Minimum equivalent fluid density Maximum depth of water filled tension crack Bending moment and displacement Method - Subgrade reaction Open Tension Crack analysis? Non-linear Modulus Parameter = = 5.00 kN/m3 0.00 m calculation: model using Influence Coefficients - No (L) = 0 m Boundary conditions: Length of wall (normal to plane of analysis) = 1000.00 m Width of excavation on active side of wall Width of excavation on passive side of wall = 20.00 m = 20.00 m Distance to rigid boundary on active side = 20.00 m Distance to rigid boundary on passive side = 20.00 m OUTPUT OPTIONS Stage ------ Stage description ----------- ------- Output options ------no. Displacement Active, Graph. Bending mom. Passive output Shear force pressures 1 Apply surcharge no.1 at elev. 28.00 No No No 2 Change EI of wall to 395349kN.m2/m run No No No 3 Excav. to elev. 27.00 on PASSIVE side No No No 4 Install strut no.1 at elev. 27.50 No No No 5 Excav. to elev. 20.00 on PASSIVE side No No No 6 Install strut no.2 at elev. 21.00 No No No 7 Excav. to elev. 13.30 on PASSIVE side No No No 8 Fill to elev. 13.80 on PASSIVE side Yes No Yes 9 Install strut no.3 at elev. 14.25 No No No 10 Install strut no.4 at elev. 17.65 No No No 11 Remove strut no.2 at elev. 21.00 No No No 12 Install strut no.5 at elev. 21.19 No No No 13 Remove strut no.1 at elev. 27.50 No No No 14 Install strut no.6 at elev. 25.91 No No No 15 Change EI of wall to 458349kN.m2/m run No No No 16 Apply surcharge no.2 at elev. 28.00 No No No 17 Change soil type 12 to soil type 14 No No No 18 Change soil type 13 to soil type 15 No No No 19 Apply surcharge no.3 at elev. 13.80 No No No 20 Apply water pressure profile no.1 No No No 21 Change EI of wall to 229174kN.m2/m run No No No 22 Change EI of wall to 197674kN.m2/m run Yes No Yes * Summary output Yes Yes Program WALLAP - Copyright (C) 2012 by DL Borin, distributed by GEOSOLVE 69 Rodenhurst Road, London SW4, UK. Tel: +44 20 8674 7251 | Sheet No. Version 6.05 Revision A38.B55.R43 | Job No. 15614 Licensed from GEOSOLVE | Made by : JBP Data filename/Run ID: 750mm Secant ULS | Project Merion - Holland Park, LONDON | Date:18-06-2014 Secant Retaining Wall - 750mm dia @ 1100mm c/c - (ULS) | Checked : ----------------------------------------------------------------------------Units: kN,m Program: WALLAP | Sheet No. Version 6.05 Revision A38.B55.R43 | Job No. 15614 Licensed from GEOSOLVE | Made by : JBP Data filename/Run ID: 750mm Secant ULS | Project Merion - Holland Park, LONDON | Date:18-06-2014 Secant Retaining Wall - 750mm dia @ 1100mm c/c - (ULS) | Checked : ----------------------------------------------------------------------------Units: kN,m Stage No. 8 Fill to elevation 13.80 on PASSIVE side with soil type 11 Program: WALLAP STABILITY ANALYSIS of Fully Embedded Wall according to Strength Factor method Factor of safety on soil strength Stage No. 8 --- G.L. --Act. Pass. 28.00 Strut Elev. 13.80 FoS for toe Toe elev. for elev. = 10.00 FoS = 1.500 --------------------------Factor Moment Toe Wall of equilib. elev. Penetr Safety at elev. -ation More than one strut BENDING MOMENT and DISPLACEMENT ANALYSIS of Fully Embedded Wall Analysis options Length of wall perpendicular to section = 1000.00m Subgrade reaction model - Boussinesq Influence coefficients Soil deformations are elastic until the active or passive limit is reached Open Tension Crack analysis - No Rigid boundaries: Active side 20.00 from wall Passive side 20.00 from wall *** Wall displacements reset to zero at stage 2 Node no. Y coord Nett pressure kN/m2 1 28.00 0.00 2 27.50 5.15 17.32 3 27.00 18.75 4 26.46 19.99 5 25.91 20.51 6 24.96 18.38 7 24.00 20.00 8 23.00 25.00 9 22.10 29.52 10 21.19 34.05 11 21.00 35.00 35.00 12 20.00 40.00 13 19.00 45.00 14 18.33 48.45 15 17.65 51.97 16 16.83 56.34 17 16.00 70.27 18 15.13 88.11 19 14.25 106.02 20 14.00 111.15 21 13.80 112.83 22 13.30 113.72 -71.53 23 12.65 -80.54 24 12.00 -76.00 25 11.00 -64.08 26 10.00 -47.56 Strut force at elev. Strut force at elev. Wall disp. m 0.001 0.002 0.002 0.004 0.005 0.007 0.010 0.012 0.015 0.018 0.021 0.022 0.022 0.026 0.030 0.033 0.035 0.037 0.038 0.038 0.037 0.036 0.036 0.034 0.034 0.032 0.030 0.026 0.022 27.50 = 21.00 = Wall Shear rotation force rad. kN/m -2.94E-03 0.0 -2.94E-03 1.3 -2.94E-03 -27.9 -2.93E-03 -18.9 -2.91E-03 -8.4 -2.88E-03 2.7 -2.86E-03 21.2 -2.88E-03 39.6 -3.00E-03 62.1 -3.25E-03 86.7 -3.69E-03 115.5 -3.82E-03 122.1 -3.82E-03 -276.6 -4.17E-03 -239.1 -3.91E-03 -196.6 -3.44E-03 -165.1 -2.79E-03 -131.2 -1.78E-03 -86.5 -6.35E-04 -34.2 6.45E-04 35.0 1.85E-03 120.0 2.17E-03 147.1 2.40E-03 169.5 2.91E-03 226.2 2.91E-03 226.2 3.37E-03 176.7 3.62E-03 125.9 3.79E-03 55.8 3.82E-03 -0.0 29.22 kN/m run = 398.67 kN/m run = Bending Strut moment forces kN.m/m kN/m -0.0 0.2 29.2 0.2 -11.0 -18.4 -19.9 -7.3 22.1 72.4 139.5 242.5 265.0 398.7 265.0 6.5 -213.1 -335.8 -436.4 -527.4 -578.8 -580.6 -514.9 -481.6 -449.9 -351.0 -351.0 -206.5 -108.9 -22.4 0.0 146.12 kN/strut 1993.33 kN/strut EI of wall kN.m2/m 395349 395349 395349 395349 395349 395349 395349 395349 395349 395349 395349 395349 395349 395349 395349 395349 395349 395349 395349 395349 395349 395349 395349 395349 395349 --- | Sheet No. Version 6.05 Revision A38.B55.R43 | Job No. 15614 Licensed from GEOSOLVE | Made by : JBP Data filename/Run ID: 750mm Secant ULS | Project Merion - Holland Park, LONDON | Date:18-06-2014 Secant Retaining Wall - 750mm dia @ 1100mm c/c - (ULS) | Checked : ----------------------------------------------------------------------------Units: kN,m Program: WALLAP | Sheet No. Version 6.05 Revision A38.B55.R43 | Job No. 15614 Licensed from GEOSOLVE | Made by : JBP Data filename/Run ID: 750mm Secant ULS | Project Merion - Holland Park, LONDON | Date:18-06-2014 Secant Retaining Wall - 750mm dia @ 1100mm c/c - (ULS) | Checked : ----------------------------------------------------------------------------Units: kN,m Program: WALLAP | Sheet No. Revision A38.B55.R43 | Job No. 15614 Licensed from GEOSOLVE | Made by : JBP Data filename/Run ID: 750mm Secant ULS | Project Merion - Holland Park, LONDON | Date:18-06-2014 Secant Retaining Wall - 750mm dia @ 1100mm c/c - (ULS) | Checked : ----------------------------------------------------------------------------Units: kN,m Stage No. 22 Change EI of wall to 197674 kN.m2/m run From elevation 13.80 to 11.00 Yield moment not defined No adjustments to wall displacements Program: WALLAP Version 6.05 STABILITY ANALYSIS of Fully Embedded Wall according to Strength Factor method Factor of safety on soil strength Stage No. 22 --- G.L. --Act. Pass. 28.00 13.80 Strut Elev. Active side 20.00 from wall Passive side 20.00 from wall *** Wall displacements reset to zero at stage 2 Node no. Y coord 1 2 28.00 27.50 3 4 5 27.00 26.46 25.91 6 7 8 9 10 24.96 24.00 23.00 22.10 21.19 11 12 13 14 15 21.00 20.00 19.00 18.33 17.65 16 17 18 19 16.83 16.00 15.13 14.25 20 14.00 21 13.80 Nett pressure kN/m2 3.68 6.19 11.11 11.62 18.52 26.26 26.26 39.82 53.67 68.77 83.03 97.43 97.43 100.41 115.98 131.70 142.35 152.73 152.73 164.50 176.89 191.15 205.39 205.39 209.29 202.93 205.89 73.89 Wall disp. m 0.039 0.039 0.039 0.039 0.038 0.038 0.038 0.037 0.036 0.035 0.035 0.034 0.034 0.034 0.035 0.036 0.036 0.037 0.037 0.038 0.038 0.038 0.038 0.038 0.038 0.038 0.038 0.038 Wall rotation rad. 8.53E-04 8.52E-04 8.52E-04 8.50E-04 8.41E-04 8.19E-04 8.19E-04 8.00E-04 8.08E-04 7.42E-04 5.07E-04 -4.48E-05 -4.48E-05 -1.91E-04 -6.64E-04 -7.89E-04 -8.12E-04 -9.06E-04 -9.06E-04 -8.86E-04 -5.55E-04 -1.16E-04 1.30E-04 1.30E-04 1.59E-04 1.59E-04 1.91E-04 1.91E-04 Shear force kN/m 0.0 2.5 2.5 8.1 16.4 28.6 -52.7 -21.2 23.5 84.7 153.4 235.0 -268.0 -249.2 -141.0 -17.2 75.3 174.9 -310.7 -179.9 -39.1 122.0 295.5 -152.5 -100.6 -100.6 -59.8 -59.8 Bending moment kN.m/m 0.0 0.7 0.7 3.5 10.1 22.3 22.3 -12.8 -12.1 40.8 147.6 334.1 334.1 284.9 87.1 4.6 23.4 107.1 107.1 -96.5 -189.0 -155.1 25.7 25.7 -6.0 -6.0 -22.0 -22.0 Node no. Y coord 22 13.30 23 12.65 24 12.00 25 11.00 26 10.00 Strut force Strut force Strut force Strut force FoS for toe Toe elev. for elev. = 10.00 FoS = 1.500 --------------------------Factor Moment Toe Wall of equilib. elev. Penetr Safety at elev. -ation More than one strut BENDING MOMENT and DISPLACEMENT ANALYSIS of Fully Embedded Wall Analysis options Length of wall perpendicular to section = 1000.00m Subgrade reaction model - Boussinesq Influence coefficients Soil deformations are elastic until the active or passive limit is reached Open Tension Crack analysis - No Rigid boundaries: Run ID. 750mm Secant ULS | Sheet No. Project Merion - Holland Park, LONDON | Date:18-06-2014 Secant Retaining Wall - 750mm dia @ 1100mm c/c - (ULS) | Checked : ----------------------------------------------------------------------------(continued) Stage No.22 Change EI of wall to 197674 kN.m2/m run From elevation 13.80 to 11.00 Yield moment not defined No adjustments to wall displacements Strut forces kN/m EI of wall kN.m2/m 229174 229174 81.3 229174 229174 229174 503.1 229174 229174 229174 229174 229174 485.6 229174 229174 229174 229174 229174 447.9 229174 229174 229174 229174 229174 197674 Nett pressure kN/m2 64.53 46.82 31.95 16.47 -8.05 -32.74 at elev. at elev. at elev. at elev. Wall disp. m 0.038 0.038 0.038 0.038 0.038 0.037 25.91 = 21.19 = 17.65 = 14.25 = Wall rotation rad. 2.32E-04 2.32E-04 2.96E-04 3.51E-04 4.03E-04 4.17E-04 81.28 kN/m 503.07 kN/m 485.63 kN/m 447.92 kN/m Shear force kN/m -25.1 -25.1 0.5 16.2 20.4 0.0 run = run = run = run = Bending Strut moment forces kN.m/m kN/m -42.6 -42.6 -36.4 -30.5 -11.0 0.0 81.28 kN/strut 503.07 kN/strut 485.63 kN/strut 447.92 kN/strut EI of wall kN.m2/m 197674 197674 197674 395349 --- | Sheet No. Revision A38.B55.R43 | Job No. 15614 Licensed from GEOSOLVE | Made by : JBP Data filename/Run ID: 750mm Secant ULS | Project Merion - Holland Park, LONDON | Date:18-06-2014 Secant Retaining Wall - 750mm dia @ 1100mm c/c - (ULS) | Checked : ----------------------------------------------------------------------------Units: kN,m Program: WALLAP Version 6.05 | Sheet No. Version 6.05 Revision A38.B55.R43 | Job No. 15614 Licensed from GEOSOLVE | Made by : JBP Data filename/Run ID: 750mm Secant ULS | Project Merion - Holland Park, LONDON | Date:18-06-2014 Secant Retaining Wall - 750mm dia @ 1100mm c/c - (ULS) | Checked : ----------------------------------------------------------------------------Units: kN,m Summary of results Program: WALLAP STABILITY ANALYSIS of Fully Embedded Wall according to Strength Factor method Factor of safety on soil strength FoS for toe Toe elev. for elev. = 10.00 FoS = 1.500 --------------------------Stage --- G.L. --Strut Factor Moment Toe Wall No. Act. Pass. Elev. of equilib. elev. Penetr Safety at elev. -ation 1 28.00 28.00 Cant. Conditions not suitable for FoS calc. 2 28.00 28.00 No analysis at this stage 3 28.00 27.00 Cant. 15.207 10.46 26.94 0.06 4 28.00 27.00 No analysis at this stage 5 28.00 20.00 27.50 2.193 n/a 18.57 1.43 6 28.00 20.00 No analysis at this stage All remaining stages have more than one strut - FoS calculation n/a | Sheet No. Revision A38.B55.R43 | Job No. 15614 Licensed from GEOSOLVE | Made by : JBP Data filename/Run ID: 750mm Secant ULS | Project Merion - Holland Park, LONDON | Date:18-06-2014 Secant Retaining Wall - 750mm dia @ 1100mm c/c - (ULS) | Checked : ----------------------------------------------------------------------------Units: kN,m Summary of results Program: WALLAP Version 6.05 BENDING MOMENT and DISPLACEMENT ANALYSIS of Fully Embedded Wall Analysis options Length of wall perpendicular to section = 1000.00m Subgrade reaction model - Boussinesq Influence coefficients Soil deformations are elastic until the active or passive limit is reached Open Tension Crack analysis - No Rigid boundaries: Active side 20.00 from wall Passive side 20.00 from wall Bending moment, shear force and displacement envelopes Node Y Displacement Bending moment no. coord maximum minimum maximum minimum m m kN.m/m kN.m/m 1 28.00 0.040 0.000 0.0 -0.0 2 27.50 0.039 0.000 0.7 0.0 3 27.00 0.039 0.000 3.5 -46.7 4 26.46 0.038 0.000 10.1 -96.1 5 25.91 0.038 0.000 22.3 -143.3 6 24.96 0.037 0.000 27.6 -217.1 7 24.00 0.036 0.000 56.5 -277.6 8 23.00 0.035 0.000 106.9 -321.8 9 22.10 0.035 0.000 174.7 -340.4 10 21.19 0.034 0.000 334.1 -323.0 11 21.00 0.034 0.000 284.9 -318.4 12 20.00 0.035 0.000 111.0 -272.8 13 19.00 0.036 0.000 37.6 -213.1 14 18.33 0.036 0.000 33.2 -335.8 15 17.65 0.037 0.000 107.1 -436.4 16 16.83 0.038 0.000 21.2 -527.4 17 16.00 0.038 0.000 21.1 -578.8 18 15.13 0.038 0.000 14.3 -580.6 19 14.25 0.038 0.000 25.7 -514.9 20 14.00 0.038 0.000 4.0 -481.6 21 13.80 0.038 0.000 2.8 -449.9 22 13.30 0.038 0.000 0.9 -351.5 23 12.65 0.038 0.000 0.0 -208.4 24 12.00 0.038 0.000 0.0 -111.0 25 11.00 0.038 0.000 0.0 -26.4 26 10.00 0.037 0.000 0.0 -0.0 Shear force maximum minimum kN/m kN/m 0.0 0.0 2.5 -95.3 8.1 -92.5 16.4 -89.0 28.6 -84.1 23.4 -71.8 40.2 -55.0 84.7 -32.5 153.4 -7.8 235.0 -268.0 122.2 -276.6 106.4 -239.1 107.5 -196.6 139.0 -165.1 174.9 -310.7 6.8 -212.8 0.2 -131.6 122.0 -50.9 295.5 -152.5 147.1 -100.6 169.5 -65.7 226.2 -25.1 176.7 -0.9 126.1 0.0 56.9 0.0 0.0 -0.0 Run ID. 750mm Secant ULS | Sheet No. Project Merion - Holland Park, LONDON | Date:18-06-2014 Secant Retaining Wall - 750mm dia @ 1100mm c/c - (ULS) | Checked : ----------------------------------------------------------------------------Summary of results (continued) Maximum and minimum bending moment and shear force at each stage Stage --------- Bending moment ----------------- Shear force ---------no. maximum elev. minimum elev. maximum elev. minimum elev. kN.m/m kN.m/m kN/m kN/m 1 0.0 27.50 -2.4 23.00 0.3 20.00 -0.9 25.91 2 No calculation at this stage 3 4.2 25.91 -4.6 15.13 3.9 27.00 -1.3 23.00 4 No calculation at this stage 5 21.2 16.83 -249.3 22.10 106.4 20.00 -77.3 27.50 6 No calculation at this stage 7 265.8 21.00 -576.8 15.13 222.6 13.30 -275.8 21.00 8 265.0 21.00 -580.6 15.13 226.2 13.30 -276.6 21.00 9 No calculation at this stage 10 No calculation at this stage 11 0.2 27.50 -393.0 14.25 172.8 17.65 -229.6 17.65 12 No calculation at this stage 13 278.1 21.19 -410.0 14.25 171.5 13.30 -237.6 17.65 14 No calculation at this stage 15 278.1 21.19 -410.0 14.25 171.5 13.30 -237.6 17.65 16 279.2 21.19 -410.4 14.25 171.7 13.30 -238.5 17.65 17 303.6 21.19 -428.2 15.13 179.6 13.30 -288.4 17.65 18 287.7 21.19 -146.7 15.13 162.7 21.19 -204.5 17.65 19 No calculation at this stage 20 334.1 21.19 -189.0 16.00 295.5 14.25 -310.7 17.65 21 No calculation at this stage 22 334.1 21.19 -189.0 16.00 295.5 14.25 -310.7 17.65 Maximum and minimum displacement at each stage Stage -------- Displacement --------Stage description no. maximum elev. minimum elev. ----------------m m 1 0.000 20.00 0.000 28.00 Apply surcharge no.1 at elev. 28.00 2 Wall displacements reset to zero Change EI of wall to 395349kN.m2/m run 3 0.002 28.00 0.000 28.00 Excav. to elev. 27.00 on PASSIVE side 4 No calculation at this stage Install strut no.1 at elev. 27.50 5 0.014 21.00 0.000 28.00 Excav. to elev. 20.00 on PASSIVE side 6 No calculation at this stage Install strut no.2 at elev. 21.00 7 0.038 15.13 0.000 28.00 Excav. to elev. 13.30 on PASSIVE side 8 0.038 16.00 0.000 28.00 Fill to elev. 13.80 on PASSIVE side 9 No calculation at this stage Install strut no.3 at elev. 14.25 10 No calculation at this stage Install strut no.4 at elev. 17.65 11 0.037 16.00 0.000 28.00 Remove strut no.2 at elev. 21.00 12 No calculation at this stage Install strut no.5 at elev. 21.19 13 0.040 28.00 0.000 28.00 Remove strut no.1 at elev. 27.50 14 No calculation at this stage Install strut no.6 at elev. 25.91 15 0.040 28.00 0.000 28.00 Change EI of wall to 458349kN.m2/m run 16 0.040 28.00 0.000 28.00 Apply surcharge no.2 at elev. 28.00 17 0.040 28.00 0.000 28.00 Change soil type 12 to soil type 14 18 0.040 28.00 0.000 28.00 Change soil type 13 to soil type 15 19 No calculation at this stage Apply surcharge no.3 at elev. 13.80 20 0.039 28.00 0.000 28.00 Apply water pressure profile no.1 21 No calculation at this stage Change EI of wall to 229174kN.m2/m run 22 0.039 28.00 0.000 28.00 Change EI of wall to 197674kN.m2/m run Run ID. 750mm Secant ULS | Sheet No. Project Merion - Holland Park, LONDON | Date:18-06-2014 Secant Retaining Wall - 750mm dia @ 1100mm c/c - (ULS) | Checked : ----------------------------------------------------------------------------Summary of results (continued) Strut forces at each stage Stage no. 5 7 8 11 13 15 16 17 18 20 22 --- Strut no. 1 --at elev. 27.50 kN/m run kN/strut 78.19 390.94 29.20 146.01 29.22 146.12 96.27 481.34 ----------------------------- Stage no. (horizontal components) --- Strut no. 2 --at elev. 21.00 kN/m run kN/strut ----398.00 1990.02 398.67 1993.33 --------------------------------- Run ID. 750mm Secant ULS | Sheet No. Project Merion - Holland Park, LONDON | Date:18-06-2014 Secant Retaining Wall - 750mm dia @ 1100mm c/c - (ULS) | Checked : ----------------------------------------------------------------------------- --- Strut no. 3 --at elev. 14.25 kN/m run kN/strut ------------slack slack slack slack slack slack slack slack slack slack 262.30 262.30 447.92 447.92 447.92 447.92 11 13 15 16 17 18 20 22 --- Strut no. 4 --at elev. 17.65 kN/m run kN/strut 402.36 402.36 251.92 251.92 251.92 251.92 253.63 253.63 342.75 342.75 285.19 285.19 485.63 485.63 485.63 485.63 --- Strut no. 5 --at elev. 21.19 kN/m run kN/strut ----280.61 280.61 280.61 280.61 282.98 282.98 371.40 371.40 347.40 347.40 503.07 503.07 503.07 503.07 --- Strut no. 6 --at elev. 25.91 kN/m run kN/strut --------0.00 0.00 8.74 8.74 41.62 41.62 45.03 45.03 81.28 81.28 81.28 81.28 | Sheet No. Revision A38.B55.R43 | Job No. 15614 Licensed from GEOSOLVE | Made by : JBP Data filename/Run ID: 750mm Secant ULS | Project Merion - Holland Park, LONDON | Date:18-06-2014 Secant Retaining Wall - 750mm dia @ 1100mm c/c - (ULS) | Checked : ----------------------------------------------------------------------------Units: kN,m Program: WALLAP Version 6.05 PILEDESIGNS Ltd. APPENDIX A PILEDESIGNS Ltd. APPENDIX A Project: Project Merion, Holland Park, LONDON Date: 19/06/2014 Project: Project Merion, Holland Park, LONDON Date: 19/06/2014 Design By: JBP Rev: 0 Design By: JBP Rev: 0 Job No: Design Ref: 15614 Job No: Design Ref: 15614 WALLAP analysis for 900mm secant (ULS), stability and embedment. WALLAP analysis for 750mm secant (SLS), moments and deflection. | Sheet No. Revision A38.B55.R43 | Job No. 15614 Licensed from GEOSOLVE | Made by : JBP Data filename/Run ID: 750mm Secant SLS | Project Merion - Holland Park, LONDON | Date:18-06-2014 Secant Retaining Wall - 750mm dia @ 1100mm c/c - (SLS) | Checked : ----------------------------------------------------------------------------Units: kN,m INPUT DATA Program: WALLAP Version 6.05 SOIL PROFILE Stratum Elevation of no. top of stratum 1 28.00 2 27.50 3 14.00 ------------------ Soil types ------------------Active side Passive side 1 Made Ground SLS (D) 1 Made Ground SLS (D) 2 W. L. Clay SLS (U) 2 W. L. Clay SLS (U) 3 L. Clay SLS (U) 3 L. Clay SLS (U) SOIL PROPERTIES -- Soil type -No. Description (Datum elev.) 1 Made Ground SLS (D) 2 W. L. Clay SLS (U) 3 L. Clay S.. ( 14.00 ) 4 W.L.Clay SLS (D) 5 L.Clay SL.. ( 14.00 ) 6 Not defined 7 Not defined 8 Not defined 9 Not defined 10 Not defined 11 Made Ground ULS (D) 12 W.L.Clay ULS (U) 13 L.Clay UL.. ( 14.00 ) 14 W.L.Clay ULS (D) 15 L.Clay UL.. ( 14.00 ) Bulk Young's At rest Consol density Modulus coeff. state. kN/m3 Eh,kN/m2 Ko NC/OC (dEh/dy ) (dKo/dy) ( Nu ) 19.00 10000 0.500 OC (0.200) 20.00 78000 1.000 OC (0.490) 20.00 78000 1.250 OC ( 5526) (0.490) 20.00 60060 1.000 OC (0.200) 20.00 60060 1.250 OC ( 4255) (0.200) 19.00 8334 20.00 52000 20.00 ( 20.00 20.00 ( 52000 3684) 40055 40055 2826) 0.577 1.000 1.250 1.000 1.250 OC (0.200) OC (0.490) OC (0.490) OC (0.200) OC (0.200) Active limit Ka ( Kac ) 0.284 (0.000) 1.000 (2.000) 1.000 (2.000) 0.351 (1.391) 0.351 (1.391) 0.351 (0.000) 1.000 (2.000) 1.000 (2.000) 0.419 (1.528) 0.419 (1.528) Passive limit Cohesion Kp kN/m2 ( Kpc ) ( dc/dy ) 4.369 ( 0.000) 1.000 130.0u ( 2.000) 1.000 130.0u ( 2.000) ( 9.210) 3.253 0.0d ( 4.831) 3.253 5.000d ( 4.831) ( ( ( ( ( 3.253 0.000) 1.000 2.000) 1.000 2.000) ( 2.597 4.198) 2.597 4.198) 86.70u 86.70u 6.140) 0.0d GROUND WATER CONDITIONS Density of water = 10.00 kN/m3 Initial water table elevation Additional soil parameters associated with Ka and Kp --- parameters for Ka --- --- parameters for Kp --Soil Wall BackSoil Wall Back------- Soil type ------- friction adhesion fill friction adhesion fill No. Description angle coeff. angle angle coeff. angle 1 Made Ground SLS (D) 30.00 0.666 0.00 30.00 0.500 0.00 2 W. L. Clay SLS (U) 0.00 0.000 0.00 0.00 0.000 0.00 3 L. Clay SLS (U) 0.00 0.000 0.00 0.00 0.000 0.00 4 W.L.Clay SLS (D) 25.00 0.666 0.00 25.00 0.500 0.00 5 L.Clay SLS (D) 25.00 0.666 0.00 25.00 0.500 0.00 6 Not defined 7 Not defined 8 Not defined 9 Not defined 10 Not defined 11 Made Ground ULS (D) 25.00 0.666 0.00 25.00 0.500 0.00 12 W.L.Clay ULS (U) 0.00 0.000 0.00 0.00 0.000 0.00 13 L.Clay ULS (U) 0.00 0.000 0.00 0.00 0.000 0.00 14 W.L.Clay ULS (D) 20.83 0.666 0.00 20.83 0.500 0.00 15 L.Clay ULS (D) 20.83 0.666 0.00 20.83 0.500 0.00 Passive side 10.00 Automatic water pressure balancing at toe of wall : Water Active side press. ------------------------------profile Point Elev. Piezo Water no. no. elev. press. m m kN/m2 1 1 27.00 27.00 0.0 No Passive side ------------------------------Point Elev. Piezo Water no. elev. press. m m kN/m2 1 13.80 13.80 0.0 2 13.80 27.00 132.0 WALL PROPERTIES Type of structure Elevation of toe of wall Maximum finite element length Youngs modulus of wall E Moment of inertia of wall I E.I Yield Moment of wall STRUTS and ANCHORS Strut/ anchor Strut no. Elev. spacing m 1 27.50 5.00 2 21.00 5.00 3 14.25 1.00 4 17.65 1.00 5 21.19 1.00 6 25.91 1.00 X-section area of strut sq.m 0.014000 0.014000 0.250000 0.250000 0.250000 0.250000 SURCHARGE LOADS Surch Distance Length -arge from parallel no. Elev. wall to wall 1 28.00 1.00(A) 25.00 2 28.00 0.00(A) 25.00 3 13.80 -0.00(P) 25.00 Note: A = Active side, 4.160d Active side 10.00 Youngs modulus kN/m2 2.800E+08 2.800E+08 1.400E+07 1.400E+07 1.400E+07 1.400E+07 = = = = = = = Fully Embedded Wall 10.00 1.00 m 2.8000E+07 kN/m2 0.014120 m4/m run 395349 kN.m2/m run Not defined Inclin Free -ation length (degs) m 15.00 0.00 15.00 0.00 15.00 0.00 15.00 0.00 15.00 0.00 15.00 0.00 Prestress /strut kN 0 0 0 0 0 0 Tension allowed No No No No No No Width Surcharge Equiv. Partial perpend. ----- kN/m2 ----- soil factor/ to wall Near edge Far edge type Category 15.00 5.00 = N/A N/A 1.00 5.00 = N/A N/A 15.00 132.00 = N/A N/A P = Passive side CONSTRUCTION STAGES Construction Stage description stage no. -------------------------------------------------------1 Apply surcharge no.1 at elevation 28.00 2 Change EI of wall to 395349 kN.m2/m run Yield moment not defined Reset wall displacements to zero at this stage 3 Excavate to elevation 27.00 on PASSIVE side 4 Install strut or anchor no.1 at elevation 27.50 5 Excavate to elevation 20.00 on PASSIVE side 6 Install strut or anchor no.2 at elevation 21.00 7 Excavate to elevation 13.80 on PASSIVE side 8 Install strut or anchor no.3 at elevation 14.25 9 Install strut or anchor no.4 at elevation 17.65 10 Remove strut or anchor no.2 at elevation 21.00 11 Install strut or anchor no.5 at elevation 21.19 12 Remove strut or anchor no.1 at elevation 27.50 13 Install strut or anchor no.6 at elevation 25.91 14 Change EI of wall to 458349 kN.m2/m run From elevation 28.00 to 13.80 Yield moment not defined Allow wall to relax with new modulus value 15 Apply surcharge no.2 at elevation 28.00 16 Change properties of soil type 2 to soil type 4 Ko pressures will not be reset 17 Change properties of soil type 3 to soil type 5 Ko pressures will not be reset 18 Apply surcharge no.3 at elevation 13.80 No analysis at this stage 19 Apply water pressure profile no.1 20 Change EI of wall to 229174 kN.m2/m run From elevation 28.00 to 13.80 Yield moment not defined No adjustments to wall displacements 21 Change EI of wall to 197674 kN.m2/m run From elevation 13.80 to 11.00 Yield moment not defined No adjustments to wall displacements FACTORS OF SAFETY and ANALYSIS OPTIONS Stability analysis: Method of analysis - Strength Factor method Factor on soil strength for calculating wall depth = 1.50 Parameters for undrained strata: Minimum equivalent fluid density Maximum depth of water filled tension crack Bending moment and displacement Method - Subgrade reaction Open Tension Crack analysis? Non-linear Modulus Parameter = = 5.00 kN/m3 0.00 m calculation: model using Influence Coefficients - No (L) = 0 m Boundary conditions: Length of wall (normal to plane of analysis) = 1000.00 m Width of excavation on active side of wall Width of excavation on passive side of wall = 20.00 m = 20.00 m Distance to rigid boundary on active side = 20.00 m Distance to rigid boundary on passive side = 20.00 m OUTPUT OPTIONS Stage ------ Stage description ----------- ------- Output options ------no. Displacement Active, Graph. Bending mom. Passive output Shear force pressures 1 Apply surcharge no.1 at elev. 28.00 No No No 2 Change EI of wall to 395349kN.m2/m run No No No 3 Excav. to elev. 27.00 on PASSIVE side No No No 4 Install strut no.1 at elev. 27.50 No No No 5 Excav. to elev. 20.00 on PASSIVE side No No No 6 Install strut no.2 at elev. 21.00 No No No 7 Excav. to elev. 13.80 on PASSIVE side Yes No Yes 8 Install strut no.3 at elev. 14.25 No No No 9 Install strut no.4 at elev. 17.65 No No No 10 Remove strut no.2 at elev. 21.00 No No No 11 Install strut no.5 at elev. 21.19 No No No 12 Remove strut no.1 at elev. 27.50 No No No 13 Install strut no.6 at elev. 25.91 No No No 14 Change EI of wall to 458349kN.m2/m run No No No 15 Apply surcharge no.2 at elev. 28.00 No No No 16 Change soil type 2 to soil type 4 No No No 17 Change soil type 3 to soil type 5 No No No 18 Apply surcharge no.3 at elev. 13.80 No No No 19 Apply water pressure profile no.1 No No No 20 Change EI of wall to 229174kN.m2/m run No No No 21 Change EI of wall to 197674kN.m2/m run Yes No Yes * Summary output Yes Yes Program WALLAP - Copyright (C) 2012 by DL Borin, distributed by GEOSOLVE 69 Rodenhurst Road, London SW4, UK. Tel: +44 20 8674 7251 | Sheet No. Revision A38.B55.R43 | Job No. 15614 Licensed from GEOSOLVE | Made by : JBP Data filename/Run ID: 750mm Secant SLS | Project Merion - Holland Park, LONDON | Date:18-06-2014 Secant Retaining Wall - 750mm dia @ 1100mm c/c - (SLS) | Checked : ----------------------------------------------------------------------------Units: kN,m Program: WALLAP Version 6.05 | Sheet No. Version 6.05 Revision A38.B55.R43 | Job No. 15614 Licensed from GEOSOLVE | Made by : JBP Data filename/Run ID: 750mm Secant SLS | Project Merion - Holland Park, LONDON | Date:18-06-2014 Secant Retaining Wall - 750mm dia @ 1100mm c/c - (SLS) | Checked : ----------------------------------------------------------------------------Units: kN,m Stage No. 7 Excavate to elevation 13.80 on PASSIVE side Program: WALLAP STABILITY ANALYSIS of Fully Embedded Wall according to Strength Factor method Factor of safety on soil strength Stage No. 7 --- G.L. --Act. Pass. 28.00 Strut Elev. 13.80 FoS for toe Toe elev. for elev. = 10.00 FoS = 1.500 --------------------------Factor Moment Toe Wall of equilib. elev. Penetr Safety at elev. -ation More than one strut BENDING MOMENT and DISPLACEMENT ANALYSIS of Fully Embedded Wall Analysis options Length of wall perpendicular to section = 1000.00m Subgrade reaction model - Boussinesq Influence coefficients Soil deformations are elastic until the active or passive limit is reached Open Tension Crack analysis - No Rigid boundaries: Active side 20.00 from wall Passive side 20.00 from wall *** Wall displacements reset to zero at stage 2 Node no. Y coord Nett pressure kN/m2 1 28.00 0.00 2 27.50 4.70 21.98 3 27.00 18.47 4 26.46 14.18 5 25.91 10.45 6 24.96 15.22 7 24.00 20.00 8 23.00 25.00 9 22.10 29.52 10 21.19 34.05 11 21.00 35.00 35.00 12 20.00 40.00 13 19.00 45.00 14 18.33 48.37 15 17.65 51.75 16 16.83 55.87 17 16.00 60.00 18 15.13 64.38 19 14.25 69.95 20 14.00 82.48 152.36 21 13.80 160.91 -102.78 22 12.90 -94.70 23 12.00 -81.85 24 11.00 -27.35 25 10.00 82.79 Strut force at elev. Strut force at elev. Wall disp. m 0.001 0.002 0.002 0.003 0.005 0.006 0.008 0.010 0.012 0.014 0.016 0.016 0.016 0.018 0.020 0.021 0.022 0.022 0.021 0.020 0.018 0.018 0.018 0.017 0.017 0.014 0.012 0.009 0.006 27.50 = 21.00 = Wall Shear rotation force rad. kN/m -2.43E-03 0.0 -2.43E-03 1.2 -2.43E-03 -44.6 -2.42E-03 -34.5 -2.39E-03 -25.6 -2.33E-03 -18.9 -2.21E-03 -6.6 -2.07E-03 10.2 -1.96E-03 32.7 -1.92E-03 57.4 -2.02E-03 86.2 -2.07E-03 92.7 -2.07E-03 -205.9 -2.08E-03 -168.4 -1.67E-03 -125.9 -1.19E-03 -94.3 -6.18E-04 -60.6 1.82E-04 -16.2 1.01E-03 31.6 1.83E-03 86.1 2.46E-03 144.8 2.59E-03 163.9 2.59E-03 163.9 2.68E-03 195.2 2.68E-03 195.2 2.88E-03 106.3 2.86E-03 26.9 2.77E-03 -27.7 2.71E-03 0.0 45.76 kN/m run = 298.57 kN/m run = Bending Strut moment forces kN.m/m kN/m 0.0 0.2 45.8 0.2 -18.8 -34.7 -46.4 -59.0 -57.7 -36.7 3.8 81.2 98.2 298.6 98.2 -90.0 -239.8 -314.9 -368.0 -401.0 -395.7 -345.5 -228.2 -189.7 -189.7 -153.9 -153.9 -21.3 34.5 41.5 -0.0 228.81 kN/strut 1492.87 kN/strut EI of wall kN.m2/m 395349 395349 395349 395349 395349 395349 395349 395349 395349 395349 395349 395349 395349 395349 395349 395349 395349 395349 395349 395349 395349 395349 395349 395349 ---
© Copyright 2025 Paperzz