FK 5000 FK 5000 MV 42,0426,0079,EN 012009 GB Operating instructions Cooling unit Dear Reader Introduction Thank you for choosing Fronius - and congratulations on your new, technically highgrade Fronius product! This instruction manual will help you get to know your new machine. Read the manual carefully and you will soon be familiar with all the many great features of your new Fronius product. This really is the best way to get the most out of all the advantages that your machine has to offer. Please also take special note of the safety rules - and observe them! In this way, you will help to ensure more safety at your product location. And of course, if you treat your product carefully, this definitely helps to prolong its enduring quality and reliability - things which are both essential prerequisites for getting outstanding results. ud_fr_st_et_00493 012004 Table of contents General ......................................................................................................................................................... Device concept ......................................................................................................................................... Variants .................................................................................................................................................... Scope of supply ........................................................................................................................................ Field of application ................................................................................................................................... Warning notices affixed to the device ...................................................................................................... 2 2 2 2 2 3 Options .......................................................................................................................................................... General .................................................................................................................................................... Return temperature and flow monitoring .................................................................................................. Coolant filter ............................................................................................................................................. 4 4 4 4 Control elements and connections ................................................................................................................ 5 Front ......................................................................................................................................................... 5 Rear ......................................................................................................................................................... 5 Fitting the cooling unit to the trolley ............................................................................................................... 6 General .................................................................................................................................................... 6 Fitting the cooling unit to the trolley .......................................................................................................... 6 Installation ..................................................................................................................................................... 7 Connecting the cooling unit and the power source .................................................................................. 7 Connecting the interconnecting hosepack to the cooling unit .................................................................. 8 Before commissioning ................................................................................................................................... 9 Safety ....................................................................................................................................................... 9 Setup regulations ..................................................................................................................................... 9 Information on the coolant ........................................................................................................................ 9 Guarantee provisions regarding the coolant pump .................................................................................. 9 Utilisation in accordance with „intended purpose“ .................................................................................. 10 Putting the cooling unit into service .............................................................................................................. 11 General ................................................................................................................................................... 11 Filling the cooling unit .............................................................................................................................. 11 Bleeding the cooling unit ......................................................................................................................... 11 Putting the cooling unit into service ........................................................................................................ 12 Care, maintenance and disposal ................................................................................................................. General .................................................................................................................................................. Symbols for care and maintenance of the cooling unit ........................................................................... At every start-up ..................................................................................................................................... Once a week .......................................................................................................................................... Every 2 months ...................................................................................................................................... Every 6 months ...................................................................................................................................... Every 6 months - in 3-shift operation ...................................................................................................... Every 12 months .................................................................................................................................... Service life of the coolant pump ............................................................................................................. Disposal ................................................................................................................................................. Validity of „General Delivery and Payment Conditions“ .......................................................................... 13 13 13 13 14 14 14 14 17 19 19 19 Troubleshooting ........................................................................................................................................... Service codes displayed on the wire-feed unit ....................................................................................... FK 5000 / FK 5000 MV ........................................................................................................................... Tightening the coolant pump shaft ......................................................................................................... 20 20 20 21 Technical data ............................................................................................................................................. 23 General .................................................................................................................................................. 23 FK 5000, FK 5000 MV ............................................................................................................................ 23 1 General Device concept The cooling unit fits perfectly into the modular product concept of the TransSteel 3500 / 5000 power sources. The cooling unit and the power source form a unit. As with the standalone power source, the power source/cooling unit combination can be mounted on the trolley. Variants Two versions of the cooling unit are produced: - FK 5000 (basic version) - FK 5000 MV (Multivoltage version) The FK 5000 MV adapts itself automatically to the mains voltage. The Multivoltage version is available only from the factory. Scope of supply The scope of supply comprises: Cooling unit 5 l coolant Four 5x25mm self-tapping screws Operating instructions Field of application The FK 5000 / FK 5000 MV cooling unit can be used for: water-cooled MIG/MAG manual welding torches water-cooled MIG/MAG machine welding torches water-cooled MIG/MAG robot welding torches 2 Warning notices affixed to the device A number of safety symbols can be seen on the cooling unit rating plate. The safety symbols must NOT be removed or painted over. The symbols warn against operating the equipment incorrectly, as this may result in serious injury and damage. Do not dispose of used cooling units with domestic waste. Dispose of them according to safety rules. Do not use the functions until you have read all the operating instructions. 3 Options General The options listed below are available for all cooling unit variants. Return temperature and flow monitoring Return temperature monitoring: A temperature sensor monitors the return temperature of the coolant. If the coolant temperature exceeds 75 °C, the sensor interrupts the welding current. The wire-feed unit outputs the error message „hot | H2O“. The temperature sensor restores the welding current when the coolant temperature falls to 65 °C again. Flow monitoring: A flow sensor monitors the coolant flow during welding. The cooling unit will switch off if the coolant flow is disrupted. The wire-feed unit outputs the error message „No | H2O“. These two components form part of an installation kit. Coolant filter The coolant filter is equipped with a CrNi screen, and its function is to filter dirt particles above 100 micrometers in size from the coolant. This ensures that no coarse dirt particles can pass into the coolant circuit. The coolant filter is installed on the cooling unit housing from the outside. 4 Control elements and connections Front (1) (2) (3) No. Function (4) (1) Water flow connection blanking cover (black) (2) Water return connection blanking cover (red) (3) Screw cap for coolant container (4) Operation and maintenance instructions (5) Coolant inspection window (5) Rear (1) No. Function (2) (4) (3) 5 (1) Power source connecting plug (2) Rating plate (3) Water flow connection (black) (4) Water return connection (red) Fitting the cooling unit to the trolley General The welding system can be fitted to a PickUp 5000 trolley to make the system (incl. cooling unit) more mobile. Important! If the welding system is not equipped with an auto-transformer, the cooling unit must be installed right at the bottom. Fitting the cooling unit to the trolley CAUTION! Risk of damage to the cooling unit. To ensure that the cooling unit is properly insulated there must be no electrical conductor connecting the base plate of the cooling unit to the bottom of the trolley. 6 Installation Connecting the cooling unit and the power source WARNING! An electric shock can be fatal. If the power source is connected to the mains electricity supply during installation, there is a high risk of very serious injury and damage. Only carry out work on the device when - the power source mains switch is in the - O - position, - the power source is unplugged from the mains. 1 2 1 2 2 7 6 3 4 1 1 2 3 5 2 CAUTION! Risk of short circuit from kinked or damaged cables. When connecting the power source to the cooling unit, ensure that the cables are not kinked. 4 3 3 2 1 1 6 5 7 4 6 CAUTION!! Danger from machines falling or toppling over. Ensure that all screw connections are secure. 7 Connecting the interconnecting hosepack to the cooling unit 8 Before commissioning Safety Setup regulations WARNING! Operating the equipment incorrectly can cause serious injury and damage. Do not use the functions described until you have thoroughly read and understood the following documents: These operating instructions All the operating instructions for the system components, especially the safety rules WARNING! If one of these machines topples over or falls it could cause serious or even fatal injury. Place device on a solid, level surface in such a way that it remains stable. Cooling air The system must be set up in such a way that the cooling air can flow unimpeded through the slots in the side panels. Dust Ensure that any metallic dust, for example from grinding work, is not sucked into the system by the fan. Outdoor operation The system can be set up and used outdoors. The built-in electrical parts must, however, be protected from direct contact with fluids (e.g. external wet cleaning). Information on the coolant The cooling unit is delivered empty. The coolant is supplied separately in a 5 l canister. Fill the cooling unit with coolant before commissioning the unit. Use only original Fronius coolant (item no. 40,0009,0046) when filling the cooling unit. Other coolants are not recommended for electrical conductivity and compatibility reasons. Guarantee provisions regarding the coolant pump The coolant pump may only be used with original coolant supplied by the manufacturer. Do not allow the coolant pump to run dry (even for a very short time), as this will destroy the coolant pump. Warranty claims will not be entertained in such cases. 9 Utilisation in accordance with „intended purpose“ The device is intended exclusively for cooling Fronius hosepacks and welding torches. The cooling unit is to be used exclusively for its intendedpurpose. Utilisation for any other purpose, or in any other manner, shall be deemed to be „not in accordance with the intended purpose“. The manufacturer is not liable for any damage, inadequate or incorrect results arising out of such misuse. Utilisation in accordance with the „intended purpose“ also comprises carefully reading and following the operating instructions and all safety and danger notices performing all stipulated inspection and servicing work. The device is designed for use in industry and the workshop. The manufacturer accepts no responsibility for any damage caused through use in a domestic setting. 10 Putting the cooling unit into service General The cooling unit is powered from the power source. If the power source mains switch is turned to position - I -, the cooling unit will also start to operate. Filling the cooling unit NOTE! If the cooling unit is being filled with coolant for the first time, it must be bled before it is used. 3 1 2 5 max. 6 Bleeding the cooling unit CAUTION!! Danger of scalding by hot coolant. Never bleed the cooling unit until it has been allowed to cool down. Bleed the cooling unit: when it has just been filled if the coolant is not circulating, even though the coolant pump is working 1 3 1 2 2 2 1 ma .23 x. 6 6 i mm nc h 4 3 4 11 5 Bleeding the cooling unit (continued) 3 4 1 1 1 2 Putting the cooling unit into service NOTE! The coolant level and cleanliness of the coolant must always be checked before starting the cooling unit. 3 1 2 5 NOTE! During welding, check at regular intervals that the coolant is flowing through properly. You should be able to see a steady return flow of coolant into the coolant container. max. 6 12 Care, maintenance and disposal General WARNING! An electric shock can be fatal. Before opening the device: Turn power source mains switch to position „O“ Unplug the power source from the mains Put up an easy-to-understand warning sign to stop anybody inadvertently switching it back on again Using a suitable measuring instrument, check to make sure that electrically charged components (e.g. capacitors) have been discharged WARNING! Operating the equipment incorrectly can cause serious injury and damage. The following activities must only be carried out by trained and qualified personnel. Take note of the „Safety rules“ chapter in the instructions for the power source and cooling unit. Under normal operating conditions the cooling unit requires only a minimum of care and maintenance. However, it is vital to observe some important points to ensure the welding system remains in a usable condition for many years. Symbols for care and maintenance of the cooling unit Change coolant The relevant maintenance intervals are described in detail on the following pages. Blow out cooler Read operating instructions At every start-up - Check welding torch, interconnecting hosepack and grounding (earthing) connection for signs of damage Check that there is a gap of 0.5 m (1ft. 7.69 in.) all around the machine to ensure that cooling air can flow and escape unhindered NOTE! Air inlets and outlets must never be covered, not even partially. CAUTION!! Danger of scalding by hot coolant. Do not check the water connections until the coolant has had time to cool down. - Check the welding torch water connections for leaks Monitor the water return in the coolant container If no water is returning, check the cooling unit and bleed if necessary NOTE! If water-cooled torches are operated without coolant, this will normally result in a fault in the torch body or hosepack. Fronius shall not be liable for any damage resulting from such action. In addition, no warranty claims will be entertained. 13 Every week CAUTION!! Danger of scalding by hot coolant. Do not check the water connections until the coolant has had time to cool down. - Check coolant level and cleanliness. If the coolant level is below the „min“ mark, top up with coolant. NOTE! Use only original Fronius coolant (40,0009,0046) when filling cooling units. Other coolants are not recommended for electrical conductivity and compatibility reasons. Every 2 months Every 6 months - Check the return for dirt and clean if necessary If present: Check that coolant filter and flow monitor are working properly and are not contaminated; clean if necessary Blow out cooling unit NOTE! Risk of damage to electronic components. Do not bring air nozzle too close to electronic components. 1 - Remove the side panels and clean the water cooler If a large amount of dust has accumulated: - Dismantle machine side panels and clean inside of machine with dry reduced compressed air Every 6 months in 3-shift operation Blow out cooling unit NOTE! Risk of damage to electronic components. Do not bring air nozzle too close to electronic components. 1 - Remove the side panels and clean the water cooler If a large amount of dust has accumulated: - Remove side panels and clean inside of machine with dry reduced compressed air 14 Every 6 months in 3-shift operation (continued) Change coolant CAUTION!! Danger of scalding by hot coolant. Never change the coolant until it has cooled down. Important! Coolant must not be disposed of in the public sewage system. NOTE! Use only original Fronius coolant (item no. 40,0009,0046) when refilling the cooling unit. 1 2 1 2 1 2 4 4 3 1 2 3 4 3 3 1 2 2 3 1 4 min. WARNING! An electric shock can be fatal. Before restarting the cooling unit, first make sure that: there is no water inside the cooling unit all the hose connections are present and correct 15 Every 6 months in 3-shift operation (continued) 5 6 1 2 3 2 max. 3 4 4 Bleed the cooling unit CAUTION!! Danger of scalding by hot coolant. Never bleed the cooling unit until it has been allowed to cool down. 1 3 1 2 2 2 1 ma .23 x. 6 6 i mm nc h 4 3 4 3 5 4 1 1 1 2 16 Change coolant Every 12 months CAUTION!! Danger of scalding by hot coolant. Never change the coolant until it has cooled down. Important! Coolant must not be disposed of in the public sewage system. NOTE! Use only original Fronius coolant (item no. 40,0009,0046) when refilling the cooling unit. 1 2 1 2 1 2 4 4 3 1 2 3 4 3 3 1 2 2 3 1 4 min. WARNING! An electric shock can be fatal. Before restarting the cooling unit, first make sure that: there is no water inside the cooling unit all the hose connections are present and correct 17 Every 12 months (continued) 5 6 1 2 3 2 max. 3 4 4 Bleed the cooling unit CAUTION!! Danger of scalding by hot coolant. Never bleed the cooling unit until it has been allowed to cool down. 1 3 1 2 2 2 1 ma .23 x. 6 6 i mm nc h 4 3 4 3 5 4 1 1 1 2 18 Service life of the coolant pump Important! If used properly the coolant pump will offer a service life of approx. 10,000 operating hours. After the end of its nominal service life, the coolant pump may develop a fault. To avoid the possibility of a lengthy work disruption the pump should be scheduled for replacement after approx. 10,000 operating hours. Disposal Dispose of in accordance with the applicable national and local regulations. Validity of „General Delivery and Payment Conditions“ With regard to cooling units, the „General Delivery and Payment Conditions“ shown in the price list only apply under the following conditions: - Max. 8 hrs/day operation (single-shift operation) Original Fronius coolant used exclusively (item number 40,0009,0046 or 40,0009,0075) Regular maintenance and regular change of coolant 19 Troubleshooting Service codes displayed on the wire-feed unit hot | H2O The optional cooling unit temperature sensor has tripped. Cause: Remedy: Coolant temperature too high Wait until the end of the cooling phase, i.e. until „hot | H2O“ is no longer displayed. ROB 5000 or field bus coupler for robot control: Before resuming welding, set the „Source error reset“ signal. no | H2O The optional cooling unit temperature sensor has tripped. FK 5000 / FK 5000 MV Cause: Remedy: Coolant flow problem Check coolant level, cleanliness and proper return; bleed cooling unit if necessary, top up with coolant Cause: Remedy: Coolant filter (option) displaced when connecting water return Clean coolant filter using clean tap water or change filter element Water flow too low or non-existent Cause: Remedy: Coolant level too low Top up coolant Cause: Remedy: Constriction or foreign body in cooling circuit Remove constriction or foreign body Cause: Remedy: Coolant pump defective Contact service team Cause: Remedy: Coolant pump sticking Tighten the coolant pump shaft - Contact the service team Cause: Remedy: Coolant filter (option) displaced when connecting water return Clean coolant filter using clean tap water or change filter element After tightening the coolant pump shaft, coolant pump not working Cause: Remedy: Thermostatic switch on coolant pump has tripped Wait until the end of coolant pump’s cooling phase (2 - 3 minutes) Insufficient cooling Cause: Remedy: Faulty fan Contact service team Cause: Remedy: Coolant pump defective Contact service team Cause: Remedy: Cooler contaminated Blow out cooler with dry compressed air 20 FK 5000 / FK 5000 MV (continued) High operating noise level Cause: Remedy: Coolant level too low Top up coolant Cause: Remedy: Coolant pump defective Contact service team The welding torch becomes very hot Cause: Remedy: The design dimensions of the torch are not sufficient for this task Observe the duty cycle and loading limits Cause: Remedy: Inadequate coolant flow Check coolant level, flow rate, contamination, etc., Coolant pump blocked: Tighten the coolant pump shaft Tighten the coolant pump shaft WARNING! An electric shock can be fatal. Before opening the device: Turn power source mains switch to position „O“ Disconnect power source from mains supply Put up an easy-to-understand warning sign to stop anybody inadvertently switching it back on again Using a suitable measuring instrument, check to make sure that electrically charged components (e.g. capacitors) have discharged WARNING! Operating the equipment incorrectly can cause serious injury and damage. The following activities must only be carried out by trained and qualified personnel. Take note of the „Safety rules“ chapter in the instructions for the power source and cooling unit. 1 1 2 3 4 5 7 6 21 Technical data General The cooling capacity of a cooling unit depends on Ambient temperature Delivery head Flow rate Q (l/min) The flow rate Q depends on the length of the interconnecting hosepack and the diameter of the hose. FK 5000, FK 5000 MV FK 5000 FK 5000 MV Mains voltage 400 V AC 200-230/400-480 V AC Mains voltage tolerance -10% / +10% -10% / +10% Mains frequency 50 / 60 Hz 50 / 60 Hz Current input 0.6 / 1.4 A 0.6 / 0.7 A Cooling power at Q = 1 l/min + 25 °C (77 °F) Q = 1 l/min + 40 °C (104 °F) Q = max. + 25 °C (77 °F) Q = max. + 40 °C (104 °F) 1100 W 800 W 1500 W 1000 W 1100 W 800 W 1500 W 1000 W Max. delivery head 35 m 114 ft. 9.95 in. 35 m 114 ft. 9.95 in. Max. delivery rate 3.5 l / min 0.92 gal./min 3.5 l / min 0.92 gal./min Max. pump pressure 4.2 bar 60.89 psi. 4.2 bar 60.89 psi. Pump Centrifugal pump Centrifugal pump Pump service life approx. 10,000 hrs. approx. 10,000 hrs. Coolant capacity 6l 1.59 gal. 6l 1.59 gal. Degree of protection IP 23 IP 23 Dimensions l/w/h 710 / 300 / 230 mm 27.95 / 11.81 / 9.06 in. 710 / 300 / 230 mm 27.95 / 11.81 / 9.06 in. Weight (without coolant) 9 kg 19.84 lb. 9.1 kg 20.06 lb Flow monitoring* Sensor Sensor Error below 0.7 l/min Error below 0.7 l/min Return temperature monitoring* Error above 75 °C Error above 75 °C Marks of conformity S, CE S, CE * Optional 22 D GB Ersatzteilliste Schaltplan Spare Parts List Circuit Diagram F Liste de pièces de rechange Schéma de connexions I Lista parti di ricambio Schema E Lista de repuestos Esquema de cableado P Lista de peças sobresselentes Esquema de conexões NL Onderdelenlijst Bedradingsschema N Reservdelsliste Koblingsplan CZ RUS SK Seznam náhradních dílů Schéma zapojení Ñïèñîê çàïàñíûõ ÷àñòåé Ýëåêòðè÷åñêàÿ ñõåìà Zoznam náhradných dielov Schéma zapojenia ud_fr_st_tb_00149 012008 4,048,001 4,048,001,630 FK 5000 FK 5000 MV 42,0401,1119 (4x) 42,0401,1118 (2x) BU2,0201,2972 option - 4,100,604 43,0009,0052 BU2,0201,2973 BU2,0201,2974 43,0001,1084 42,0401,1118 (6x) option - 4,100,612 44,0001,1145 43,0001,1131 42,0402,0236 42,0405,0186 - RED 42,0405,0187 - BLACK 42,0201,0105 44,0001,1398 42,0401,0962 44,0001,1238 44,0001,1253 42,0405,0694 43,0006,0223 4,071,074,Z FKR2500 4,071,073,Z FKC2500 - MV 42,0300,2859 BU2,0201,2976 42,0405,0696 24,0450,1039 43,0006,0170 42,0405,0695 42,0300,2856 42,0401,1116 (4x) 42,0401,0937 42,0201,2969 42,0300,1564 33,0030,0114 - MV 42,0201,2975 42,0405,0693 40,0006,3004 40,0001,0496 -* 40,0009,0046 FK 5000 Ersatzteilliste / Spare parts list / Listes de pièces de rechange / Lista de repuestos / Lista de pecas sobresselentes / Lista dei Ricambi el_fr_st_kg_01719 1/1 012009 FK 5000 FK 5000 MV FRONIUS INTERNATIONAL GMBH Buxbaumstraße 2, A-4600 Wels, Austria Tel: +43 (0)7242 241-0, Fax: +43 (0)7242 241-3940 E-Mail: [email protected] www.fronius.com www.fronius.com/addresses Under http://www.fronius.com/addresses you will find all addresses of our Sales & service partners and Locations. ud_fr_st_so_00082 012008
© Copyright 2026 Paperzz