Roll-in Showers - Comfort Designs

no
Roll-in
seat Showers
608.5.2 In standard roll-in type
shower compartments, the
controls, faucets, and shower
spray unit shall be located above
the grab bar, but no higher than
48 inches (1220 mm) above the
shower floor.
Advisory 608.5.2 In standard rollin type showers without seats,
the shower head and operable
parts can be located on any of
the three walls of the shower
without adversely affecting
accessibility.
608.3.2 Where a seat is not
provided in standard roll-in type
shower compartments, grab bars
shall be provided on three walls.
Grab bars shall be installed 6
inches (150 mm) maximum from
adjacent walls.
code c o m p l i a n t c u r b l e s s s h ow e r s
6 0 8 . 2.2 Standard roll-in type shower compartments shall
b e 3 0 inches (760 mm) wide minimum by 60 inches (1525
m m ) deep minimum clear inside dimensions measured at
c e n t er points of opposing sides and shall have a 60 inches
( 1 5 2 5 mm) wide minimum entry on the face of the shower
c o m p artment.
Roll-in showers are the most universal
in their ability to meet the needs of
transfer patients, roll-in patients or
stand-up bathers.
configuration A:
back wall
Valve placement
Either configuration A or B is
compliant when no seat is present.
A non-ambulatory patient can
maneuver to access the valve at either
location.
configuration B:
either side wall
Entry bar
Assist with balance and stability
during entr y and exit for standing
bathers.
Integral soap ledge
conveniently placed for access
Low threshold
allowing easy maneuvering
XSA 6436 BF .75
Design Journal ADEX - Award for Design Excellence
Shown in U-bar configuration with out seat
roll-in shower thresholds
Advisory 608.1 General.
Shower stalls that
are 60 inches (1525
mm) wide and have no
curb may increase the
rol l - i n thr
usability of a bathroom
because the shower
area provides additional
maneuvering space.
XSA 6430 BF .75
floor transition illustrated on roll-in shower
seat
608.5.2 In standard roll-in type
shower compartments, where a
seat is provided, the controls,
faucets, and shower spray unit
shall be installed on the back wall
adjacent to the seat wall and shall
be located 27 inches (685 mm)
maximum from the seat wall.
608.3.2 Where a seat is provided
in standard roll-in type shower
compartments, grab bars shall be
provided on the back wall and the
side wall opposite the seat. Grab
bars shall not be provided above
the seat.
Configuration with seat
valve and hand held shower
kit are within reach of
seated bather
XSA 6430 BF .75
shown in L-bar configuration
with frameless phenolic seat
finished floor area
1/2” max. rise with
bevel (2:1 max. slope
3/4”
bedding compound
1/4”
floor construction
CODE
area stiffened for
additional support
1/4”
COMPLIANT
Cutout or recess so
drain is below floor
level and additional
slope is provided
finished floor area
3/4”
Cutout or recess so
drain is below floor
level and additional
slope is provided
roll-in
showers
608.7 Thresholds in roll-in type
shower compartments shall be
1/2 inch (13 mm) high maximum in
accordance with 303.
303.1 Where changes in level are
permitted in floor or ground
surfaces, they shall comply
with 303.
res h o l d s
additional
subfloor
bedding
compound
floor construction
303.2 Changes in level of 1/4 inch
(6.4 mm) high maximum shall be
permitted to be vertical.
3