...Start with accuracy, finish with quality CFS Narrow Body Wizard Boilerless Tunnel Finisher SELF-CONTAINED, SIMPLE SYSTEM FOR ON-SITE FINISHING WITHOUT THE NEED OF A BOILER A tunnel finishing system suited for small or remote installations where a high pressure boiler system is not available or desirable. The “Wizard” technology (patent pending) uses a built-in steam generating unit to eliminate the need for an external boiler to supply the steam for fabric relaxation. In the small OPL (on-premise laundry) this effectively replaces the boiler, piping, water feed systems and chemicals, a dryer, and a main garment press. Benefits: • Non-pressurized system means no boiler restrictions or regulations • Simple water and drain connection • Use ordinary tap water • Built-in filtration system • Electrically-heated system generation, water supply and electrically-heated air section (EWE) • Optional gas heating for steam generation and/or heated air section (EWG, GWG) CFS 90 EWE Production Rate hk/hr Application 75 Damp-to-Dry 150 - 300 Dry-to-Dry CFS 300 EWE/GWG Production Rate hk/hr Application 250 Damp-to-Dry 500 Dry-to-Dry Specifications CFS 90 EWE CFS 300 EWE CFS 300 GWG Length (in/mm) 110 (2794) 170 (4318) 170 (4318) Width (in/mm) 55 (1387) 55 (1387) 55 (1387) Dimensions Height (in/mm) 80 (2032) 80 (2032) 80 (2032) Shipping Weight (lbs/kg) 1770 (805) 3450 (1564) 3450 (1564) 75 - 300 250 - 500 250 - 500 Production Garments per hour Electrical Electrical Supply 3 phase Water Requirements Water Supply: (mm) Drain Connection: (mm) Water Consumption: (l/hr) 3/8” (9.52) 3/8” (9.52) 3/8” (9.52) 3/4” (19.05) 3/4” (19.05) 3/4” (19.05) 13.5 gph (51.1) 13.5 gph (51.1) 13.5 gph (51.1) n/a 2” (50.90) Natural Gas Requirements Line Size: (mm) n/a Supply Pressure: (BAR) Minimum n/a n/a 10 inWC (0.02) Maximum n/a n/a 15 inWC (0.03) Maximum - start-up n/a n/a 210,000 Btu/hr (221,500) Average - operating n/a n/a 210,000 Btu/hr (221,500) Maximum - start-up n/a n/a 250,000 Btu/hr (63,000) Average - operating n/a n/a 125,000 Btu/hr (31,500) Consumption - Humidifier: (kJ/hr) Consumption - Heat Total: (kJ/hr) Options: • Leveling pads, for leveling on uneven floors and elevation for cleaning underneath • Dropped-garment safety switch shuts off the tunnel finisher in the event a garment should fall off of its hanger, reducing the possibility of fabric damage The rate of finishing is dependent on garment type, and quality requirements. The guidelines are recommended starting points. Narrow Body conveyors are capable of speeds exceeding the listed guideline production rates 2 Underwriters Laboratory, Inc. (UL.com) 3 FM Global (FMGLOBAL.com) 4 Unavailable on CFS 40, our smallest Narrow Body 1 ...Start with accuracy, finish with quality P.O. Box 72 • Colville, WA 99114 USA Tel: (509) 684-4505 • (800) 926-5622 • Fax: (509) 684-4500 [email protected] • www.colmacind.com
© Copyright 2026 Paperzz