lumencove® nano 2.0 Specification Sheet WHITE Client Project name Order#Type Qty FEATURES AND BENEFITS Physical : 1f t • Polymer extruded housing • Available in 1' or 4' [0.3m or 1.2m] sections • Adjustable mounting brackets, +/- 81° aiming (tool-less) • Beam angle: 120° x 120° • IP20 • White standard finish • Clear high-transmittance polycarbonate injected lens, frosted lens option available • Indoor applications, dry/damp location only • 10 year limited warranty1 up 20 da 5W 15 te /ft 09 d te 25 st ed va l Electrical : • • • • • • • Performance summary sf or CRI value: 80+ Binning within a 2 step MacAdam ellipse Color temperatures: 2700K, 3000K, 3500K or 4000K Lumen maintenance 100,000 hrs [L70 @ 25°C] Lumen measurements comply with LM-79-08 standard Operating temperatures: 0° C to 50° C [32F to 122F] 4ft fixture, clear lens* ue • • • • • • Powered by HO Performance : Line voltage luminaire for 120V, 230V or 277V Powered by Lumendrive AC step drive, no power supply onboard Power and data in 1 cable (#16-4), white cable and connector standard Thumb latch connectors, breakable under load 3W/ft - RO version, 5W/ft - HO version Dimming options: 0-10V, DMX and DALI dimming enabled with Digital Data Bridge (accessory) Lumentalk network enabled with Lumentalk Data Bridge (accessory) RO - Regular output HO - High output** CCT [K] Delivered output [lm] Efficacy [lm/W] Delivered output [lm] Efficacy [lm/W] 2700K 1,188 99.2 1,668 87.6 3000K 1,310 109.6 1,696 89.1 3500K 1,265 105.7 1,868 98.5 4000K 1,358 114.2 1,840 97.9 *1ft fixture delivered output ratio = x0.25 Frosted lens option delivered output ratio = x0.85 **Estimated. Consult website for latest ies files and reports. 1 1 8 ", 47 2 " [309mm, 1206mm] 12 TOP VIEW 7 1 " 16 [36mm] 1 Minimum 2" [14mm] end to end spacing 3 " 8 [35mm] 1 FRONT VIEW 7 3 9 44 " 16 ", 4 [239mm, 1137mm] 3 " 8 [60mm] 2 3 3 " 16 [81mm] 81° 81° SIDE VIEW Maximum Pivot Limits Adjustable in 9° increments BOTTOM VIEW 1 The limited 10-year warranty is only valid if the product is operated in an ambient environment that does not exceed 25 °C. Otherwise, our limited 5-year warranty shall apply. 1/7 © Copyright Lumenpulse 2017 2017.03.30 1751 Richardson, Suite 1505 Montreal (Quebec) Canada H3K 1G6 GS - R1 1.877.937.3003 P.514.937.3003 F. 514.937.6289 [email protected] www.lumenpulsegroup.com 10-year limited warranty. Consult www.lumenpulsegroup.com for our complete Standard Terms and Conditions of Sales. Lumenpulse reserves the right to make changes to this product at any time without prior notice and such modification shall be effective immediately. lumencove® nano 2.0 Specification Sheet WHITE MOUNTING DETAILS MOUNTING PLATE DIMENSIONS Ø 3" 16 [5mm] 11 " 4 [32mm] BREAKABLE TAB 13 " 17 " 16 8 [20mm] [48mm] Ø 3" 16 [5mm] 5 " 32 [4mm] SUGGESTED COVE DIMENSIONS 120° 111 " 16 [43mm] 111 " 16 [43mm] 3" [76mm] Suggested cove dimensions for minimum cove height MAXIMUM ANGLE ADJUSTMENT A jumper cable is required for angles greater than 45°. TOP VIEW 45˚ 2/7 © Copyright Lumenpulse 2017 2017.03.30 1751 Richardson, Suite 1505 Montreal (Quebec) Canada H3K 1G6 GS - R1 1.877.937.3003 P.514.937.3003 F. 514.937.6289 [email protected] www.lumenpulsegroup.com 10-year limited warranty. Consult www.lumenpulsegroup.com for our complete Standard Terms and Conditions of Sales. Lumenpulse reserves the right to make changes to this product at any time without prior notice and such modification shall be effective immediately. lumencove® nano 2.0 Specification Sheet WHITE ACCESSORIES Order separately, refer to each item’s specification sheet for ordering information Cables (required): Leader Cable for Lumencove® Nano 2.0, 10ft (3m) or 25ft (7.6m) standard lengths* Jumper Cable for Lumencove® Nano 2.0, 2ft (0.6m) or 4ft (1.2m) standard lengths Digital Data Bridge (required for dimming applications)*: Digital Data Bridge converts 0-10V, DALI and DMX control protocols to be compatible with Lumencove® Nano 2.0. *A Digital Data Bridge is included with every leader cable specified for dimming applications. Refer to the LCN2 leader cable specification sheet for details. 45" 16 [110mm] 4" [102mm] 45" 16 [110mm] TOP VIEW 4" [102mm] TOP VIEW 29" 16 [65mm] 21" 4 [58mm] FRONT VIEW SIDE VIEW FRONT VIEW UL version SIDE VIEW CE version Lumentalk Data Bridge (optional dimming accessory): DMX, 0-10V and TRIAC inputs enabled via Lumentranslator for the Lumentalk network. Lumentalk control enabled with Lumentalk Data Bridge. 5 6 16 " [160mm] 5 5 " 16 [135mm] For 4x 1/4-20 UNC (M6) screws TOP VIEW 11 " 16 [169mm] 1 78" [180mm] 6 9 3 " 16 [91mm] FRONT VIEW 3/7 © Copyright Lumenpulse 2017 2017.03.30 1751 Richardson, Suite 1505 Montreal (Quebec) Canada H3K 1G6 GS - R1 SIDE VIEW 1.877.937.3003 P.514.937.3003 F. 514.937.6289 [email protected] www.lumenpulsegroup.com 10-year limited warranty. Consult www.lumenpulsegroup.com for our complete Standard Terms and Conditions of Sales. Lumenpulse reserves the right to make changes to this product at any time without prior notice and such modification shall be effective immediately. lumencove® nano 2.0 Specification Sheet WHITE TYPICAL WIRING DIAGRAMS Wiring Color Code American Color Code CE USE Color Code Black White Red Orange Brown Blue Black Grey Maximum run length - Lumencove® Nano 2.0 RO & HO Live Neutral Data + Data - Cable length/Voltage 120V 230V 277V 25ft [8m] leader cable 150ft [46m] 300ft [91m] 300ft [91m] Non-Dimming (NO) Non-Dimming (NO) - Wiring detail Non-Dimming A B C D A E B G C D E F A - Power input B - To fixture C - Line D - Neutral E - Ground F - Wire-nuts (by others) G - Junction box (by others) A - Power input (120V, 230V or 277V, to match fixture specified voltage) B - Junction box (by others) C - Leader cable (LCN2LC) D - Lumencove Nano 2.0 (LCN2) E - Jumper cable (LCN2JC) Notes: • Consult factory for specific applications and maximum fixture count/cable length recommendations. • Regular Output version: 3 watts per foot [0.3m], High Output version: 5 watts per foot [0.3m]. 4/7 © Copyright Lumenpulse 2017 2017.03.30 1751 Richardson, Suite 1505 Montreal (Quebec) Canada H3K 1G6 GS - R1 1.877.937.3003 P.514.937.3003 F. 514.937.6289 [email protected] www.lumenpulsegroup.com 10-year limited warranty. Consult www.lumenpulsegroup.com for our complete Standard Terms and Conditions of Sales. Lumenpulse reserves the right to make changes to this product at any time without prior notice and such modification shall be effective immediately. lumencove® nano 2.0 Specification Sheet WHITE TYPICAL WIRING DIAGRAMS - continued Wiring Color Code American Color Code CE USE Color Code Black White Red Orange Brown Blue Black Grey Maximum run length using Digital Data Bridge Lumencove® Nano 2.0 RO & HO Cable length/Voltage Live Neutral Data + Data - 25ft [8m] leader cable 120V 230V 150ft [46m] 277V Maximum cable length between Digital Data Bridge and 1st fixture in run 100ft [30m] (#16-4 cable) 0-10V, DALI or DMX Dimming (Digital Data Bridge required) 10% minimum dimming value for 0-10V dimming, 5% minimum dimming value for DALI and DMX dimming A - Power input (120V, 230V or 277V, to match fixture specified voltage) B - Third party dimmer/DALI or DMX controller C - Digital Data Bridge (DDB-DIM, DDB-DALI or DDB-DMX) D - Leader cable (LCN2LC) E - Lumencove Nano 2.0 (LCN2) F - Jumper cable (LCN2JC) C A D E F B Wiring Detail using Digital Data Bridge DDB-DIM, DDB-DALI or DDB-DMX (UL) D C INPUT OUTPUT E B A F G H I N M L K J A - Power input (to match fixture specified voltage) B - Ground (green) C - Data + D - Data E - Data - (orange) F - Power and data output to fixture (4 or 5C/cable) G - Data + (red) H - Neutral (white) I - Line (black) J - Data input from third party dimmer/controller K - Data - (orange) L - Data + (purple) M - Neutral (white) N - Line (black) G - Junction box (by others) Wiring Detail using Digital Data Bridge DDB-DIM, DDB-DALI or DDB-DMX (CE) INPUT OUTPUT B A C K J I H G A - Power input (to match fixture specified voltage) B - Data - (grey) C - Power and data output to fixture (4 or 5C/cable) D - Data + (black) E - Neutral (blue) F - Line (brown) G - Data input from third party dimmer/controller H - Data - (grey) I - Data + (black) J - Line (brown) K - Neutral (blue) D E F Notes: • Consult factory for specific applications and maximum fixture count/cable length recommendations. • 0-10V mA ratings: passive dimmer (Current Sink): 3mA per fixture, active dimmer (Current Source): 0.5mA per fixture. • Regular Output version: 3 watts per foot [0.3m], High Output version: 5 watts per foot [0.3m]. 5/7 © Copyright Lumenpulse 2017 2017.03.30 1751 Richardson, Suite 1505 Montreal (Quebec) Canada H3K 1G6 GS - R1 1.877.937.3003 P.514.937.3003 F. 514.937.6289 [email protected] www.lumenpulsegroup.com 10-year limited warranty. Consult www.lumenpulsegroup.com for our complete Standard Terms and Conditions of Sales. Lumenpulse reserves the right to make changes to this product at any time without prior notice and such modification shall be effective immediately. lumencove® nano 2.0 Specification Sheet WHITE TYPICAL WIRING DIAGRAMS - continued Wiring Color Code American Color Code CE USE Color Code Black White Red Orange Brown Blue Black Grey Maximum run length using Lumentalk Data Bridge Lumencove® Nano 2.0 RO & HO Cable length/Voltage 120V 25ft [8m] leader cable Live Neutral Data + Data - 230V 277V Maximum cable length between Digital Data Bridge and 1st fixture in run 100ft [30m] (#16-4 cable) 150ft [46m] Lumentalk (LT, Lumentranslator, Lumentalk Data Bridge and Digital Data Bridge required) 10 % minimum dimming value A - Third party dimmer/DMX controller B - Lumentranslator (LTL-010, -DMX) C - Data wiring (by others) D - Power line (120-277V AC) E - Lumentalk Data Bridge (LDB-DIM or LDB-DMX) F - Digital Data Bridge (DDB-DIM or DDB-DMX) G - Leader cable (LCN2LC) H - Lumencove Nano 2.0 (LCN2) I - Jumper cable (LCN2JC) B F A C D E F G H I Wiring detail using LDB (LDB-DIM or LDB-DMX) Wiring Detail using Digital Data Bridge DDB-DIM or DDB-DMX (UL) B C D E A D C INPUT INPUT OUTPUT E B A F A - Power input (control over power line via Lumentalk system) B - Line C - Neutral D - 0-10V + / Data + E - 0-10V - / Data F - To next fixture G - To Digital Data Bridge Wiring Detail using Digital Data Bridge DDB-DIM or DDB-DMX (CE) OUTPUT B A C F N M L K G H I J A - Power input (to match fixture specified voltage) B - Ground (green) C - Data + D - Data E - Data - (orange) F - Power and data output to fixture (4 or 5C/cable) G - Data + (red) H - Neutral (white) I - Line (black) J - Data input from third party dimmer/controller K - Data - (orange) L - Data + (purple) M - Neutral (white) N - Line (black) G - Junction box (by others) K J I H G D E F A - Power input (to match fixture specified voltage) B - Data - (grey) C - Power and data output to fixture (4 or 5C/cable) D - Data + (black) E - Neutral (blue) F - Line (brown) G - Data input from third party dimmer/controller H - Data - (grey) I - Data + (black) J - Line (brown) K - Neutral (blue) Notes: • Consult factory for specific applications and maximum fixture count/cable length recommendations. • Lumentalk Data Bridge and Digital Data Bridge required for Lumentalk applications. All fixtures attached to the Digital Data Bridge will act as 1 zone. For applications with all fixtures controlled as 1 zone: Digital Data Bridge and Lumentalk Data Bridge must be specified as DIM. Maximum of 24 Digital Data Bridges per Lumentalk Data Bridge (LDB-DIM). Consult factory for details. For applications where each Digital Data Bridge is a separate zone: Digital Data Bridge and Lumentalk Data Bridge must be specified as DMX. Maximum of 24 Digital Data Bridges per Lumentalk Data Bridge (LDB-DMX). • For DMX applications: 1 DMX controller per Lumentalk network, maximum of 48 DMX channels per Lumentalk network (minimum step transition update rate is 1 second, minimum fade time between two colors is 1 minute). Consult factory for applications that require additional capabilities. • Maximum of 1 transmitter (Lumentranslator or Lumenlink) per system • No third party fixtures allowed on the same circuit. • Consult factory for DALI Lumentalk applications. • Regular Output version: 3 watts per foot [0.3m], High Output version: 5 watts per foot [0.3m]. 6/7 © Copyright Lumenpulse 2017 2017.03.30 1751 Richardson, Suite 1505 Montreal (Quebec) Canada H3K 1G6 GS - R1 1.877.937.3003 P.514.937.3003 F. 514.937.6289 [email protected] www.lumenpulsegroup.com 10-year limited warranty. Consult www.lumenpulsegroup.com for our complete Standard Terms and Conditions of Sales. Lumenpulse reserves the right to make changes to this product at any time without prior notice and such modification shall be effective immediately. lumencove® nano 2.0 Specification Sheet WHITE HOW TO ORDER LCN2 Select: Select: Select: Select: Select: Select: 2 3 4 5 6 1 1 WH 7 6 Housing: Lens: LCN2 RO - Lumencove® Nano 2.0, Regular Output 3W/ft LCN2 HO - Lumencove® Nano 2.0, High Output 5W/ft 2 CL - Clear lens FR - Frosted lens 7 Certification: Finish: UL - UL compliant CE - CE compliant WH - White (standard finish) 3 Notes: LCN2 is suitable for non-dimming and dimming applications. For dimming applications, a Digital Data Bridge is required. Specify a dimming control option in the LCN2 leader cable order code. Voltage: 120 - 120 volts 230 - 230 volts 277 - 277 volts Consult the LCN2 leader cable specification sheet for more information, as well as the accessories page of this specification sheet. 4 Length: 12 - 12 1/8 inches (309mm) (0.23kg/0.5 lbs) 48 - 47 1/2 inches (1206mm) (0.68kg/1.5 lbs) 5 Colors and Color temperatures: 27K - 2700K 30K - 3000K 35K - 3500K 40K - 4000K 7/7 © Copyright Lumenpulse 2017 2017.03.30 1751 Richardson, Suite 1505 Montreal (Quebec) Canada H3K 1G6 GS - R1 1.877.937.3003 P.514.937.3003 F. 514.937.6289 [email protected] www.lumenpulsegroup.com 10-year limited warranty. Consult www.lumenpulsegroup.com for our complete Standard Terms and Conditions of Sales. Lumenpulse reserves the right to make changes to this product at any time without prior notice and such modification shall be effective immediately.
© Copyright 2026 Paperzz