Ranges Consult factory for other engineering units. 3½ digit display indicates up to 19.99, 199.9, or 1999. Some ranges may require models with 4-digit display. Specify if minus sign is required for vacuum models. InHg/psig –29.9 inHg-15 psi –29.9 inHg-100 psi –29.9 inHg-200 psi Pounds/sq. in. 0-3 psi 0-5 psi 15-0 psia 0-14.7 psi vac –14.7-15.0 psi 0-15 psi 30-0 psia 0-30 psi 0-60 psi 100-0 psia –14.7-100 psi 0-100 psi –14.7-200 psi 0-200 psi 0-300 psi 0-500 psi 0-1000 psi 0-3000 psi 0-5000 psi inches Hg (0°C) 0-6 inHg 0-10 inHg 30-0 inHg abs 0-29.9 inHg vac –29.9-30.0 inHg 0-30 inHg 60-0 inHg abs 0-60 inHg 0-120 inHg 200-0 inHg abs 0-200 inHg In. H2O (20°C) 0-85 inH2O 0-140 inH2O 400-0 inH2O abs 0-408 inH2O vac ±408 inH2O 0-400 inH2O 850-0 inH2O abs 0-850 inH2O Ft. H2O (20°C) 0-7 ftH2O 0-12 ftH2O 0-35 ftH2O 0-70 ftH2O 0-140 ftH2O 0-230 ftH2O 0-480 ftH2O 0-700 ftH2O 0-1150 ftH2O 0-2300 ftH2O 0-6900 ftH2O Ounces/sq. in. 0-50 oz/in2 0-80 oz/in2 240-0 oz/in2 abs 0-235 oz/in2 vac –235-240 oz/in2 0-240 oz/in2 kiloPascals 0-20 kPa 0-35 kPa 100-0 kPa abs 0-101 kPa vac 0-20 kPa 0-35 kPa kiloPascals 100-0 kPa abs 0-101 kPa vac –101-100 kPa 0-100 kPa 200-0 kPa abs 0-200 kPa 0-400 kPa 700-0 kPa abs –101-700 kPa 0-700 kPa –101-1400 kPa 0-1400 kPa 0-2000 kPa 0-3500 kPa 0-7000 kPa MegaPascal –0.1-0.7 MPa –0.1-1.4 MPa 0-1.4 MPa 0-2 MPa 0-3.5 MPa 0-7 MPa 0-20 MPa 0-35 MPa Millibar 0-200 mbar 0-350 mbar 1000-0 mbar abs 0-1013 mbar vac –1013-1000 mbar 0-1000 mbar 2000-0 mbar abs 0-2000 mbar 0-4000 mbar Bar 1-0 bar abs 1.01 bar vac –1.01-1 bar 0-1 bar 2-0 bar abs 0-2 bar 0-4 bar 7-0 bar abs –1.01-7 bar 0-7 bar –1.01-14 bar 0-14 bar 0-20 bar 0-35 bar 0-70 bar 0-200 bar 0-350 bar kilograms/cm2 1-0 kg/cm2 abs 0-1.03 kg/cm2 vac –1.03-1 kg/cm2 0-1 kg/cm2 2-0 kg/cm2 abs 0-2 kg/cm2 0-4 kg/cm2 7-0 kg/cm2 abs –1.03-7 kg/cm2 0-7 kg/cm2 –1.03-14 kg/cm2 0-14 kg/cm2 0-20 kg/cm2 0-35 kg/cm2 0-70 kg/cm2 0-200 kg/cm2 0-350 kg/cm2 Cecomp8_2010.indd 1 Range Code –30V15PSIG –30V100PSIG –30V200PSIG Range Code 3PSIG 5PSIG 15PSIA 15PSIGVAC ±15PSIG 15PSIG 30PSIA 30PSIG 60PSIG 100PSIA –15V100PSIG 100PSIG –15V200PSIG 200PSIG 300PSIG 500PSIG 1000PSIG 3000PSIG 5000PSIG Range Code 6INHGG 10INHGG 30INHGA 30INHGVAC ±30INHGG 30INHGG 60INHGA 60INHGG 120INHGG 200INHGA 200INHGG Range Code 85INH2OG 140INH2OG 400INH2OA 400INH2OVAC ±400INH2OG 400INH2OG 850INH2OA 850INH2OG Range Code 7FTH2O 12FTH2O 35FTH2O 70FTH2O 140FTH2O 230FTH2O 480FTH2O 700FTH2O 1150FTH2O 2300FTH2O 6900FTH2O Range Code 50ZING 80ZING 240ZINA 240ZINVAC ±240ZING 240ZING Range Code 20KPAG 35KPAG 100KPAA 100KPAVAC 20KPAG 35KPAG PSI –14.7-15.0 –14.7-100 –14.7-200 PSI 3.0 5.0 15.0 abs –14.7 –14.7-15.0 15.0 30.0 abs 30.0 60.0 100 abs –14.7-100 100 –14.7-200 200 300 500 1000 3000 5000 PSI 3.0 4.9 14.7 abs –14.7 ±14.7 14.7 29.5 abs 29.5 58.9 98.2 abs 98.2 PSI 3.1 5.1 14.5 abs –14.7 ±14.7 14.5 30.7 abs 30.7 PSI 3.0 5.2 15.2 30.3 60.7 99.7 208 303 498 995 2986 PSI 3.1 5.0 15.0 abs –14.7 –14.7-15.0 15.0 PSI 2.9 5.1 14.5 abs –14.7 2.9 5.1 Range Code 100KPAA 100KPAVAC ±100KPAG 100KPAG 200KPAA 200KPAG 400KPAG 700KPAA –100V700KPAG 700KPAG –100V1400KPAG 1400KPAG 2000KPAG 3500KPAG 7000KPAG Range Code –0.1V0.7MPAG –0.1V1.4MPAG 1.4MPAG 2MPAG 3.5MPAG 7MPAG 20MPAG 35MPAG Range Code 200MBARG 350MBARG 1000MBARA 1000MBARVAC ±1000MBARG 1000MBARG 2000MBARA 2000MBARG 4000MBARG Range Code 1BARA 1BARVAC ±1BARG 1BARG 2BARA 2BARG 4BARG 7BARA 1V7BARG 7BARG 1V14BARG 14BARG 20BARG 35BARG 70BARG 200BARG 350BARG Range Code 1KGCMA 1KGCMGVAC ±1KGCMG 1KGCMG 2KGCMA 2KGCMG 4KGCMG 7KGCMA –1V7KGCMG 7KGCMG –1V14KGCMG 14KGCMG 20KGCMG 35KGCMG 70KGCMG 200KGCMG 350KGCMG PSI 14.5 abs –14.7 –14.7-14.5 14.5 29.0 abs 29.0 58 102 abs –14.7-102 102 –14.7-203 203 290 508 1015 PSI –14.7-102 –14.7-203 203 290 508 1015 2901 5076 PSI 2.9 5.1 14.5 abs –14.7 –14.7-14.5 14.5 29.0 abs 29.0 58.0 PSI 14.5 abs –14.7 –14.7-14.5 14.5 29.0 abs 29.0 58.0 102 abs –14.7-102 102 –14.7-203 203 290 508 1015 2901 5076 PSI 14.2 abs –14.7 –14.7-14.2 14.2 28.4 abs 28.4 56.9 99.6 abs –14.2-99.6 99.6 –14.2-199 199 284 498 996 2845 4978 Battery Powered Gauges 15 psig, 100 psig, 200 psig, and absolute sensors are for vacuum service. grams/cm2 Range Code 1000-0 g/cm2 abs 1000GCMA 0-1037 g/cm2 vac 1000GCMVAC 0-1000 g/cm2 1000GCMG 2100-0 g/cm2 abs 2100GCMA 0-2100 g/cm2 2100GCMG mmHg (0°C) Range Code 0-150 mmHg 150MMHGG 0-260 mmHg 260MMHGG 760-0 mmHg abs 760MMHGA 0-760 mmHg vac 760MMHGVAC ±760 mmHg ±760MMHGG 0-760 mmHg 760MMHGG 1600-0 mmHg 1600MMHGA 0-1600 mmHg 1600MMHGG Torr (0°C) Range Code 760-0 Torr 760TORRA 1600-0 Torr 1600TORRA cm H2O (20°C) Range Code 0-210 cmH2O 210CMH2OG 0-350 cmH2O 350CMH2OG 0-1000 cmH2O 1000CMH2OG 0-2100 cmH2O 2100CMH2OG mm H2O (20°C) Range Code 0-2100 mmH2O 2100MMH2OG 0-3500 mmH2O 3500MMH2OG Atmospheres Range Code 1-0 atm abs 1ATMA ±1 atm ±1ATMG 0-1 atm 1ATMG 0-2 atm abs 2ATMA 0-2 atm 2ATMG 0-4 atm 4ATMG 0-7 atm 7ATMG 0-14 atm 14ATMG 0-20 atm 20ATMG 0-34 atm 34ATMG 0-70 atm 70ATMG 0-200 atm 200ATMG 0-340 atm 340ATMG PSI 14.2 abs –14.7 14.2 29.9 abs 29.9 PSI 2.9 5.0 14.7 abs –14.7 ±14.7 14.7 30.9 abs 30.9 PSI 14.7 abs 30.9 abs PSI 3.0 5.0 14.2 29.9 PSI 3.0 5.0 PSI 14.7 abs ±14.7 14.7 29.4 abs 29.4 58.8 103 206 294 500 1029 2939 4997 1220 American Way Libertyville, IL 60048 ★ ★ ★ ★ ★ ★ ★ ★ ★ ★ ★ ★ ★ ★ ★ ★ ★ ★ ★ ★ ★ ★ ★ ★ ★ ★ ★ ★ ★ ★ ★ ★ ★ ★ ★ ★ ★ ★ ★ ★ ★ ★ ★ ★ ★ ★ ★ ★ ★ ★ Made in USA Precision RTD Element NEMA 4X Housing 316L Stainless Steel Probe 1/2" NPT for Standard Thermowells Local Temperature Display Refrigerator or Oven Temperatures Transmitter for PLC Temperature Input Temperature Out-of-Limits Alarm Air Dryer Outlet Temperature –58.0 to 392.0°F or –50.0 to 200.0°C, selectable Resolution Accuracy ±0.1% of span, plus maximum sensor error of ±0.3°C at 0°C, ±1.1°C at 150°C Includes linearity, hysteresis, repeatability 4 readings per second nominal display update rate 4 digit LCD, 0.5" digit height, alphanumeric lower display NEMA 4X 3.5" W x 3.0" H x 2.0" D for housing only UV stabilized ABS/polycarbonate case, polycarbonate window, rubber rear gasket Connection and Probe Material ½" NPT male, 316L stainless steel Operating Temperature –4 to 185°F (–20 to 85°C) at housing T16B Battery Powered Indicator Includes 2 AA batteries Battery life approximately 1000 hours BL backlit version battery life approx. 150 to 750 hours T16L Loop Powered Transmitter Powered by 8 to 32 VDC current loop Reverse polarity protected 3 ft long, 2-conductor 22 AWG cable 4-20 mA output, approx. 12,000 counts, updated 4 times per second Configurable temperature range to correspond to 4-20 mA output, configurable for upscale or downscale burnout T16ADA Dual Temperature Alarm Powered by 8 to 24 VAC 50/60 Hz or 9 to 32 VDC Reverse polarity protected 3 ft long, 2-conductor 22 AWG cable 2 SPDT relays, 1A/24VDC, 0.5A/115VAC non-inductive Programmable setpoints, High or Low Normal or reverse acting, programmable hysteresis Front panel LED alarm status indication –4 to 185 185°F °F (–2 (–20 to 85°C) Info Quick Link cecomp.com/battery Compensated Temperature 32 to t 158°F (0 to 70°C) ARM760 760B ARM760B DPG1000B F16B F18BN, NEMA 4X F20B F22B with RB Rubber Boot DPG1000 & F4 ranges to 1999 Factory set to 5, 10, 30 minutes, or on/off DPG1000 & F4 ranges 2000-up, F16, F18, F20, F22 Factory set to any number of minutes or hours ThermoPro T16B Indicator Probe Display Auto Racing Tire Pressure Operating Temperature Auto Shutoff Sensor 316L SS sheath, 1/4" diameter Replaceable probe assembly Fixed length probe: Welded to hex nipple Spring-loaded probe: For use with thermowells 3000 psig range an and metr e ic equivalents: s 5000 psig 5000 psig range an nd metric equivalents: 7500 psig All otherrs 2 times normal sensor pressure rating Burst: 4 tim imes es sen sensor s pressure rating, or 10,000 0 psi, whi hiche chever ver is le less ss ARM760, DPG1000 & F4 ranges to 1999 Front push button turns gauge on or off Front-accessible calibration potentiometers Non-interactive zero and span, ±10% range DPG1000 & F4 ranges 2000-up, F16, F18, F20, F22 Front push button turns gauge on or off, zeroes gauge Internal calibration push buttons Non-interactive zero and span, ±10% range © 2009 Matthew Wolfe, Branded Media Group Info Quick Link cecomp.com/thermopro 0.1°F or 0.1°C resolution 100 Ohm RTD element, 0.00385 alpha coefficient IEC-751 Class B: ±0.3°C at 0°C, ±1.1°C at 150°C 10 second time constant Overpressure & Burst Controls & Calibration Range Batteries & Battery Life L= Thermowelll Probe Length Two AA alkaline B ranges up to 1999: Approx. 2500 hours B ranges 2000-up: Approx. 2000 hours BBL ranges up to 1999: Approx. 180 hours BBL ranges 2000-up: Approx. 150 to 1500 hours Low battery symbol on display when batteries must bee replaced ThermoPro T16L Transmitter Housings See thermowell manufacturer’s ctttu ture ure rer’’ss specifications. specifi Measure stem length from m to ttop p of threads. Fixed Length Probe T16B2 T16B4 T16B6 T16B9 T16B12 T16BBL2 T16BBL4 T16BBL6 T16BBL9 T16BBL12 T16L2 T16L4 T16L6 T16L9 T16L12 T16ADA2 T16ADA4 T16ADA6 T16ADA9 T16ADA12 T16ADABL2 T16ADABL4 T16ADABL6 T16ADABL9 T16ADABL12 Spring-Loaded for Thermowells T16B2S T16B4S T16B6S T16B9S T16B12S T16BBL2S T16BBL4S T16BBL6S T16BBL9S T16BBL12S T16L2S T16L4S T16L6S T16L9S T16L12S T16ADA2S T16ADA4S T16ADA6S T16ADA9S T16ADA12S T16ADABL2S T16ADABL4S T16ADABL6S T16ADABL9S T16ADABL12S Standard: 3.38" W x 2.88" H x 1.65" D Epoxy powder coated aluminum case, ABS/ polycarbonate bezel, front and rear gaskets NEMA 4X: 3.5" W x 3.0" H x 2.0" D UV stabilized ABS/polycarbonate case, polycarbonate window, rear gasket Add approximately 0.75" to height for pressure fitting ThermoPro T16ADA Alarm Housing -TP Top Port Option ¼" NPT malee, 316 3 L SS wett e ed parts ARM760, DPG1000 & F4 ranges to 1999 3 readings per second nominal display update rate 3½ digit LCD, 0.5" H digits DPG1000 & F4 ranges 2000-up, F16, F18, F20, F22 3 readings per second nominal display update rate 4 digit LCD, 0.5" H, 0.25" H alphanumeric lower display BL: Red LED display backlight ThermoPro Temperature Indicators, Transmitters, Alarms User settable pass code required for calibration mode d Zero and span temperature calibration RB Rubber Boot Pressure/Vacuum Connection & Material Display ® Portable and Rugged Test Gauge Auto Racing Tire Pressure Leak Down Testing ARM Replaces Mercury Manometers See range table for available engineering units Vacuum to 5000 psi, absolute, bipolar, compound ARM760: 760 Torr absolute ±0.25% of full scale ±1 least significant digit, includes linearity, hysteresis, repeatability See cecomp.com for latest product information. Call 800-942-0315 for questions or quotes. See www.cecomp.com/pdf/cecompprices.pdf for latest pricing. Ranges Accuracy Calibration Pressure Gauge Options and Accessories Option Add to end of model number -CC Moisture resistant circuit board coating. -ET Extended temperature display (–40 to 85°C), includes CC -HA High accuracy, ±0.1% FS ±1 LSD. Some ranges require 4-digit display. Not available with 3 psi sensor, compound, vacuum, or bipolar ranges. -PM Panel mount, 4.1" x 4.1", not for NEMA models. -SM Surface mount plate. Battery powered models only, not for NEMA models. -MC Metal bezel instead of plastic. Synthetic oil resistant. Std. on DPG2000, not for NEMA models. -TP Top Port. Fitting at top of case. Battery-powered gauges only. -CS Case stiffener to reinforce bottom of case for tire pressure applications. Std. on DPG2000. Accessories NC NIST certificate; 5 test points, test date, NIST traceability documentation CD 5 point factory calibration data with test date RB Protective rubber boot, not for NEMA models. WMPSK Wall mount power supply kit, 115VAC/12VDC ±0.25% Accuracy, 316L SS Sensor Proven Stability and Reliability Models with Selectable Units, Memory Digi-Max with Min/Max, Zero Length "L" 2.5" L 4" L 6" L 9" L 12" L 2.5" L 4" L 6" L 9" L 12" L 2.5" L 4" L 6" L 9" L 12" L 2.5" L 4" L 6" L 9" L 12" L 2.5" L 4" L 6" L 9" L 12" L atures Features Power Battery powered temperature indicator 2 AA batteries, 1000 hrs. Battery powered temperature indicator, with red LED display backlight 2-wire 4-20 mA loop powered transmitter Temperature alarm, 2 SPDT relays, programmable Temperature alarm, 2 SPDT relays, programmable, with red LED display backlight 2 AA batteries, 150 to 750 hrs. 8-32 VDC loop power 8 to 24 VAC or 9 to 32 VDC 8 to 24 VAC or 9 to 32 VDC Div. of Absolute Process Instruments, Inc. 1220 American Way Phone: 800-942-0315 15 Libertyville, IL 60048 Fax: 800-949-7502 cecomp.com ★ ★ ★ ★ ★ ★ ★ ★ ★ ★ ★ ★ ★ ★ ★ ★ ★ ★ ★ ★ ★ ★ ★ ★ ★ ★ ★ ★ ★ ★ ★ ★ ★ ★ ★ ★ ★ ★ ★ ★ ★ ★ ★ ★ ★ ★ ★ ★ ★ ★ Made in USA Signal Conditioners & Isolators Process Transmitters Electrical Power Monitors Custom Electronics api-usa.com API maintains a constant effort to upgrade and improve its products. Specifications are subject to change without notice. Consult factory for your specific requirements. Carina Nebula taken by the Hubble Space Telescope Space Telescope Science Institute, hubblesite.org © Absolute Process Instruments, Inc. 09/10 Model ARM760B ARM760BBL DPG1000B DPG1000BBL F4B F4BBL F16B F16BBL F16BN F16BNBL F18B F18BBL F18BN F18BNBL F20B F20BBL F20BN F20BNBL F22B F22BBL F22BN F22BNBL Ranges NEMA 760 Torr absolute Vacuum to 5000 psi, absolute, compound, ± bipolar Vacuum to 5000 psi, absolute, compound, ± bipolar Vacuum to 5000 psi, absolute, compound, ± bipolar Vacuum to 5000 psi, absolute, compound, ± bipolar Vacuum to 5000 psi, absolute, compound, ± bipolar Model Series See table below _______________ Backlight Red LED Red LED 4X 4X Red LED Red LED 4X 4X Red LED Red LED 4X 4X Red LED Red LED 4X 4X Keypad 1 button on/off Zero Front zero pot. 1 button on/off Front zero pot. Calibration Units Front zero, Factory set span pots. Red LED 1 button on/off, zero, Hold button cycle through at startup min/max 1 button on/off, zero, Hold button cycle through at startup min/max Options See options list _______________ Memory Shutoff none Factory set to 5 minutes -5 -10 -30 -ON 5 min., factory set 10 min., factory set 30 min., factory set on/off, factory set Front zero, span pots. Factory set none Internal buttons Factory set Min/max Factory set -5, -10, -30, minutes or -1H, -2H, -3H hours -ON, or desired time Internal buttons Internal button select Min/max Internal button select to desired minutes or hours or continuous on Red LED Red LED 4X 4X To Order Range Auto Shutoff Time See range table Default for F18, F20, F22 _______________ _______________ 3 button on/off, zero/clear, , Keypad zero Keypad with 4 or 6 max Keypad select button pass code readings Keypad select to desired minutes or hours or continuous on 3 button on/off, zero/clear, , Keypad zero Keypad with Keypad select button pass code Keypad select to desired minutes or hours or continuous on Min/max CEC-8C 8/31/2010 10:27:36 AM
© Copyright 2026 Paperzz