Ranges Ther

Ranges
Consult factory for other engineering units.
3½ digit display indicates up to 19.99, 199.9, or 1999.
Some ranges may require models with 4-digit display.
Specify if minus sign is required for vacuum models.
InHg/psig
–29.9 inHg-15 psi
–29.9 inHg-100 psi
–29.9 inHg-200 psi
Pounds/sq. in.
0-3 psi
0-5 psi
15-0 psia
0-14.7 psi vac
–14.7-15.0 psi
0-15 psi
30-0 psia
0-30 psi
0-60 psi
100-0 psia
–14.7-100 psi
0-100 psi
–14.7-200 psi
0-200 psi
0-300 psi
0-500 psi
0-1000 psi
0-3000 psi
0-5000 psi
inches Hg (0°C)
0-6 inHg
0-10 inHg
30-0 inHg abs
0-29.9 inHg vac
–29.9-30.0 inHg
0-30 inHg
60-0 inHg abs
0-60 inHg
0-120 inHg
200-0 inHg abs
0-200 inHg
In. H2O (20°C)
0-85 inH2O
0-140 inH2O
400-0 inH2O abs
0-408 inH2O vac
±408 inH2O
0-400 inH2O
850-0 inH2O abs
0-850 inH2O
Ft. H2O (20°C)
0-7 ftH2O
0-12 ftH2O
0-35 ftH2O
0-70 ftH2O
0-140 ftH2O
0-230 ftH2O
0-480 ftH2O
0-700 ftH2O
0-1150 ftH2O
0-2300 ftH2O
0-6900 ftH2O
Ounces/sq. in.
0-50 oz/in2
0-80 oz/in2
240-0 oz/in2 abs
0-235 oz/in2 vac
–235-240 oz/in2
0-240 oz/in2
kiloPascals
0-20 kPa
0-35 kPa
100-0 kPa abs
0-101 kPa vac
0-20 kPa
0-35 kPa
kiloPascals
100-0 kPa abs
0-101 kPa vac
–101-100 kPa
0-100 kPa
200-0 kPa abs
0-200 kPa
0-400 kPa
700-0 kPa abs
–101-700 kPa
0-700 kPa
–101-1400 kPa
0-1400 kPa
0-2000 kPa
0-3500 kPa
0-7000 kPa
MegaPascal
–0.1-0.7 MPa
–0.1-1.4 MPa
0-1.4 MPa
0-2 MPa
0-3.5 MPa
0-7 MPa
0-20 MPa
0-35 MPa
Millibar
0-200 mbar
0-350 mbar
1000-0 mbar abs
0-1013 mbar vac
–1013-1000 mbar
0-1000 mbar
2000-0 mbar abs
0-2000 mbar
0-4000 mbar
Bar
1-0 bar abs
1.01 bar vac
–1.01-1 bar
0-1 bar
2-0 bar abs
0-2 bar
0-4 bar
7-0 bar abs
–1.01-7 bar
0-7 bar
–1.01-14 bar
0-14 bar
0-20 bar
0-35 bar
0-70 bar
0-200 bar
0-350 bar
kilograms/cm2
1-0 kg/cm2 abs
0-1.03 kg/cm2 vac
–1.03-1 kg/cm2
0-1 kg/cm2
2-0 kg/cm2 abs
0-2 kg/cm2
0-4 kg/cm2
7-0 kg/cm2 abs
–1.03-7 kg/cm2
0-7 kg/cm2
–1.03-14 kg/cm2
0-14 kg/cm2
0-20 kg/cm2
0-35 kg/cm2
0-70 kg/cm2
0-200 kg/cm2
0-350 kg/cm2
Cecomp8_2010.indd 1
Range Code
–30V15PSIG
–30V100PSIG
–30V200PSIG
Range Code
3PSIG
5PSIG
15PSIA
15PSIGVAC
±15PSIG
15PSIG
30PSIA
30PSIG
60PSIG
100PSIA
–15V100PSIG
100PSIG
–15V200PSIG
200PSIG
300PSIG
500PSIG
1000PSIG
3000PSIG
5000PSIG
Range Code
6INHGG
10INHGG
30INHGA
30INHGVAC
±30INHGG
30INHGG
60INHGA
60INHGG
120INHGG
200INHGA
200INHGG
Range Code
85INH2OG
140INH2OG
400INH2OA
400INH2OVAC
±400INH2OG
400INH2OG
850INH2OA
850INH2OG
Range Code
7FTH2O
12FTH2O
35FTH2O
70FTH2O
140FTH2O
230FTH2O
480FTH2O
700FTH2O
1150FTH2O
2300FTH2O
6900FTH2O
Range Code
50ZING
80ZING
240ZINA
240ZINVAC
±240ZING
240ZING
Range Code
20KPAG
35KPAG
100KPAA
100KPAVAC
20KPAG
35KPAG
PSI
–14.7-15.0
–14.7-100
–14.7-200
PSI
3.0
5.0
15.0 abs
–14.7
–14.7-15.0
15.0
30.0 abs
30.0
60.0
100 abs
–14.7-100
100
–14.7-200
200
300
500
1000
3000
5000
PSI
3.0
4.9
14.7 abs
–14.7
±14.7
14.7
29.5 abs
29.5
58.9
98.2 abs
98.2
PSI
3.1
5.1
14.5 abs
–14.7
±14.7
14.5
30.7 abs
30.7
PSI
3.0
5.2
15.2
30.3
60.7
99.7
208
303
498
995
2986
PSI
3.1
5.0
15.0 abs
–14.7
–14.7-15.0
15.0
PSI
2.9
5.1
14.5 abs
–14.7
2.9
5.1
Range Code
100KPAA
100KPAVAC
±100KPAG
100KPAG
200KPAA
200KPAG
400KPAG
700KPAA
–100V700KPAG
700KPAG
–100V1400KPAG
1400KPAG
2000KPAG
3500KPAG
7000KPAG
Range Code
–0.1V0.7MPAG
–0.1V1.4MPAG
1.4MPAG
2MPAG
3.5MPAG
7MPAG
20MPAG
35MPAG
Range Code
200MBARG
350MBARG
1000MBARA
1000MBARVAC
±1000MBARG
1000MBARG
2000MBARA
2000MBARG
4000MBARG
Range Code
1BARA
1BARVAC
±1BARG
1BARG
2BARA
2BARG
4BARG
7BARA
1V7BARG
7BARG
1V14BARG
14BARG
20BARG
35BARG
70BARG
200BARG
350BARG
Range Code
1KGCMA
1KGCMGVAC
±1KGCMG
1KGCMG
2KGCMA
2KGCMG
4KGCMG
7KGCMA
–1V7KGCMG
7KGCMG
–1V14KGCMG
14KGCMG
20KGCMG
35KGCMG
70KGCMG
200KGCMG
350KGCMG
PSI
14.5 abs
–14.7
–14.7-14.5
14.5
29.0 abs
29.0
58
102 abs
–14.7-102
102
–14.7-203
203
290
508
1015
PSI
–14.7-102
–14.7-203
203
290
508
1015
2901
5076
PSI
2.9
5.1
14.5 abs
–14.7
–14.7-14.5
14.5
29.0 abs
29.0
58.0
PSI
14.5 abs
–14.7
–14.7-14.5
14.5
29.0 abs
29.0
58.0
102 abs
–14.7-102
102
–14.7-203
203
290
508
1015
2901
5076
PSI
14.2 abs
–14.7
–14.7-14.2
14.2
28.4 abs
28.4
56.9
99.6 abs
–14.2-99.6
99.6
–14.2-199
199
284
498
996
2845
4978
Battery Powered Gauges
15 psig, 100 psig, 200 psig, and absolute sensors are for
vacuum service.
grams/cm2
Range Code
1000-0 g/cm2 abs
1000GCMA
0-1037 g/cm2 vac
1000GCMVAC
0-1000 g/cm2
1000GCMG
2100-0 g/cm2 abs
2100GCMA
0-2100 g/cm2
2100GCMG
mmHg (0°C)
Range Code
0-150 mmHg
150MMHGG
0-260 mmHg
260MMHGG
760-0 mmHg abs
760MMHGA
0-760 mmHg vac
760MMHGVAC
±760 mmHg
±760MMHGG
0-760 mmHg
760MMHGG
1600-0 mmHg
1600MMHGA
0-1600 mmHg
1600MMHGG
Torr (0°C)
Range Code
760-0 Torr
760TORRA
1600-0 Torr
1600TORRA
cm H2O (20°C)
Range Code
0-210 cmH2O
210CMH2OG
0-350 cmH2O
350CMH2OG
0-1000 cmH2O
1000CMH2OG
0-2100 cmH2O
2100CMH2OG
mm H2O (20°C)
Range Code
0-2100 mmH2O
2100MMH2OG
0-3500 mmH2O
3500MMH2OG
Atmospheres
Range Code
1-0 atm abs
1ATMA
±1 atm
±1ATMG
0-1 atm
1ATMG
0-2 atm abs
2ATMA
0-2 atm
2ATMG
0-4 atm
4ATMG
0-7 atm
7ATMG
0-14 atm
14ATMG
0-20 atm
20ATMG
0-34 atm
34ATMG
0-70 atm
70ATMG
0-200 atm
200ATMG
0-340 atm
340ATMG
PSI
14.2 abs
–14.7
14.2
29.9 abs
29.9
PSI
2.9
5.0
14.7 abs
–14.7
±14.7
14.7
30.9 abs
30.9
PSI
14.7 abs
30.9 abs
PSI
3.0
5.0
14.2
29.9
PSI
3.0
5.0
PSI
14.7 abs
±14.7
14.7
29.4 abs
29.4
58.8
103
206
294
500
1029
2939
4997




1220 American Way
Libertyville, IL 60048
★ ★ ★ ★ ★ ★
★ ★ ★ ★ ★
★ ★ ★ ★ ★ ★
★ ★ ★ ★ ★
★ ★ ★ ★ ★ ★
★ ★ ★ ★ ★
★ ★ ★ ★ ★ ★
★ ★ ★ ★ ★
★ ★ ★ ★ ★ ★
Made
in
USA




Precision RTD Element
NEMA 4X Housing
316L Stainless Steel Probe
1/2" NPT for Standard Thermowells




Local Temperature Display
Refrigerator or Oven Temperatures
Transmitter for PLC Temperature Input
Temperature Out-of-Limits Alarm
Air Dryer Outlet Temperature
–58.0 to 392.0°F or –50.0 to 200.0°C, selectable
Resolution
Accuracy
±0.1% of span, plus maximum sensor error of
±0.3°C at 0°C, ±1.1°C at 150°C
Includes linearity, hysteresis, repeatability
4 readings per second nominal display update rate
4 digit LCD, 0.5" digit height, alphanumeric lower display
NEMA 4X
3.5" W x 3.0" H x 2.0" D for housing only
UV stabilized ABS/polycarbonate case, polycarbonate
window, rubber rear gasket
Connection and Probe Material
½" NPT male, 316L stainless steel
Operating Temperature
–4 to 185°F (–20 to 85°C) at housing
T16B Battery Powered Indicator
Includes 2 AA batteries
Battery life approximately 1000 hours
BL backlit version battery life approx. 150 to 750 hours
T16L Loop Powered Transmitter
Powered by 8 to 32 VDC current loop
Reverse polarity protected
3 ft long, 2-conductor 22 AWG cable
4-20 mA output, approx. 12,000 counts, updated 4
times per second
Configurable temperature range to correspond to 4-20
mA output, configurable for upscale or downscale
burnout
T16ADA Dual Temperature Alarm
Powered by 8 to 24 VAC 50/60 Hz or 9 to 32 VDC
Reverse polarity protected
3 ft long, 2-conductor 22 AWG cable
2 SPDT relays, 1A/24VDC, 0.5A/115VAC non-inductive
Programmable setpoints, High or Low
Normal or reverse acting, programmable hysteresis
Front panel LED alarm status indication
–4 to 185
185°F
°F (–2
(–20 to 85°C)
Info Quick Link
cecomp.com/battery
Compensated Temperature
32 to
t 158°F (0 to 70°C)
ARM760
760B
ARM760B
DPG1000B
F16B
F18BN, NEMA 4X
F20B
F22B with RB Rubber Boot
DPG1000 & F4 ranges to 1999
Factory set to 5, 10, 30 minutes, or on/off
DPG1000 & F4 ranges 2000-up, F16, F18, F20, F22
Factory set to any number of minutes or hours
ThermoPro
T16B
Indicator
Probe
Display
Auto Racing Tire Pressure
Operating Temperature
Auto Shutoff
Sensor
316L SS sheath, 1/4" diameter
Replaceable probe assembly
Fixed length probe: Welded to hex nipple
Spring-loaded probe: For use with thermowells
3000 psig range an
and metr
e ic equivalents:
s 5000 psig
5000 psig range an
nd metric equivalents: 7500 psig
All otherrs 2 times normal sensor pressure rating
Burst: 4 tim
imes
es sen
sensor
s pressure rating, or 10,000
0 psi,
whi
hiche
chever
ver is le
less
ss
ARM760, DPG1000 & F4 ranges to 1999
Front push button turns gauge on or off
Front-accessible calibration potentiometers
Non-interactive zero and span, ±10% range
DPG1000 & F4 ranges 2000-up, F16, F18, F20, F22
Front push button turns gauge on or off, zeroes gauge
Internal calibration push buttons
Non-interactive zero and span, ±10% range
© 2009 Matthew Wolfe, Branded Media Group
Info Quick Link
cecomp.com/thermopro
0.1°F or 0.1°C resolution
100 Ohm RTD element, 0.00385 alpha coefficient
IEC-751 Class B: ±0.3°C at 0°C, ±1.1°C at 150°C
10 second time constant
Overpressure & Burst
Controls & Calibration
Range
Batteries & Battery Life
L=
Thermowelll
Probe
Length
Two AA alkaline
B ranges up to 1999:
Approx. 2500 hours
B ranges 2000-up:
Approx. 2000 hours
BBL ranges up to 1999: Approx. 180 hours
BBL ranges 2000-up: Approx. 150 to 1500 hours
Low battery symbol on display when batteries must bee
replaced
ThermoPro
T16L
Transmitter
Housings
See thermowell manufacturer’s
ctttu
ture
ure
rer’’ss specifications.
specifi
Measure stem length from
m to
ttop
p of threads.
Fixed Length
Probe
T16B2
T16B4
T16B6
T16B9
T16B12
T16BBL2
T16BBL4
T16BBL6
T16BBL9
T16BBL12
T16L2
T16L4
T16L6
T16L9
T16L12
T16ADA2
T16ADA4
T16ADA6
T16ADA9
T16ADA12
T16ADABL2
T16ADABL4
T16ADABL6
T16ADABL9
T16ADABL12
Spring-Loaded for
Thermowells
T16B2S
T16B4S
T16B6S
T16B9S
T16B12S
T16BBL2S
T16BBL4S
T16BBL6S
T16BBL9S
T16BBL12S
T16L2S
T16L4S
T16L6S
T16L9S
T16L12S
T16ADA2S
T16ADA4S
T16ADA6S
T16ADA9S
T16ADA12S
T16ADABL2S
T16ADABL4S
T16ADABL6S
T16ADABL9S
T16ADABL12S
Standard: 3.38" W x 2.88" H x 1.65" D
Epoxy powder coated aluminum case, ABS/
polycarbonate bezel, front and rear gaskets
NEMA 4X: 3.5" W x 3.0" H x 2.0" D
UV stabilized ABS/polycarbonate case, polycarbonate
window, rear gasket
Add approximately 0.75" to height for pressure fitting
ThermoPro
T16ADA
Alarm
Housing
-TP Top Port Option
¼" NPT malee, 316
3 L SS wett
e ed parts
ARM760, DPG1000 & F4 ranges to 1999
3 readings per second nominal display update rate
3½ digit LCD, 0.5" H digits
DPG1000 & F4 ranges 2000-up, F16, F18, F20, F22
3 readings per second nominal display update rate
4 digit LCD, 0.5" H, 0.25" H alphanumeric lower display
BL: Red LED display backlight
ThermoPro Temperature Indicators, Transmitters, Alarms
User settable pass code required for calibration mode
d
Zero and span temperature calibration
RB Rubber Boot
Pressure/Vacuum Connection & Material
Display
®
Portable and Rugged Test Gauge
Auto Racing Tire Pressure
Leak Down Testing
ARM Replaces Mercury Manometers
See range table for available engineering units
Vacuum to 5000 psi, absolute, bipolar, compound
ARM760: 760 Torr absolute
±0.25% of full scale ±1 least significant digit, includes
linearity, hysteresis, repeatability
See cecomp.com for latest product information. Call 800-942-0315 for questions or quotes. See www.cecomp.com/pdf/cecompprices.pdf for latest pricing.




Ranges
Accuracy
Calibration
Pressure Gauge Options and Accessories
Option Add to end of model number
-CC Moisture resistant circuit board coating.
-ET Extended temperature display (–40 to 85°C),
includes CC
-HA High accuracy, ±0.1% FS ±1 LSD. Some ranges
require 4-digit display. Not available with 3 psi
sensor, compound, vacuum, or bipolar ranges.
-PM Panel mount, 4.1" x 4.1", not for NEMA models.
-SM Surface mount plate. Battery powered models
only, not for NEMA models.
-MC Metal bezel instead of plastic. Synthetic oil resistant. Std. on DPG2000, not for NEMA models.
-TP Top Port. Fitting at top of case. Battery-powered
gauges only.
-CS Case stiffener to reinforce bottom of case for tire
pressure applications. Std. on DPG2000.
Accessories
NC
NIST certificate; 5 test points, test date, NIST
traceability documentation
CD
5 point factory calibration data with test date
RB
Protective rubber boot, not for NEMA models.
WMPSK Wall mount power supply kit, 115VAC/12VDC
±0.25% Accuracy, 316L SS Sensor
Proven Stability and Reliability
Models with Selectable Units, Memory
Digi-Max with Min/Max, Zero
Length
"L"
2.5" L
4" L
6" L
9" L
12" L
2.5" L
4" L
6" L
9" L
12" L
2.5" L
4" L
6" L
9" L
12" L
2.5" L
4" L
6" L
9" L
12" L
2.5" L
4" L
6" L
9" L
12" L
atures
Features
Power
Battery powered
temperature indicator
2 AA batteries,
1000 hrs.
Battery powered
temperature indicator,
with red LED display
backlight
2-wire 4-20 mA
loop powered
transmitter
Temperature alarm,
2 SPDT relays,
programmable
Temperature alarm,
2 SPDT relays,
programmable,
with red LED display
backlight
2 AA batteries,
150 to 750 hrs.
8-32 VDC
loop power
8 to 24 VAC or
9 to 32 VDC
8 to 24 VAC or
9 to 32 VDC
Div. of Absolute Process Instruments, Inc.
1220 American Way Phone: 800-942-0315
15
Libertyville, IL 60048 Fax:
800-949-7502
cecomp.com
★ ★ ★ ★ ★ ★
★ ★ ★ ★ ★
★ ★ ★ ★ ★ ★
★ ★ ★ ★ ★
★ ★ ★ ★ ★ ★
★ ★ ★ ★ ★
★ ★ ★ ★ ★ ★
★ ★ ★ ★ ★
★ ★ ★ ★ ★ ★
Made
in
USA
Signal Conditioners & Isolators
Process Transmitters
Electrical Power Monitors
Custom Electronics
api-usa.com
API maintains a constant effort to upgrade and improve its products. Specifications
are subject to change without notice. Consult factory for your specific requirements.
Carina Nebula taken by the Hubble Space Telescope
Space Telescope Science Institute, hubblesite.org
© Absolute Process Instruments, Inc. 09/10
Model
ARM760B
ARM760BBL
DPG1000B
DPG1000BBL
F4B
F4BBL
F16B
F16BBL
F16BN
F16BNBL
F18B
F18BBL
F18BN
F18BNBL
F20B
F20BBL
F20BN
F20BNBL
F22B
F22BBL
F22BN
F22BNBL
Ranges
NEMA
760 Torr absolute
Vacuum to 5000 psi,
absolute, compound,
± bipolar
Vacuum to 5000 psi,
absolute, compound,
± bipolar
Vacuum to 5000 psi,
absolute, compound,
± bipolar
Vacuum to 5000 psi,
absolute, compound,
± bipolar
Vacuum to 5000 psi,
absolute, compound,
± bipolar
Model Series
See table below
_______________
Backlight
Red LED
Red LED
4X
4X
Red LED
Red LED
4X
4X
Red LED
Red LED
4X
4X
Red LED
Red LED
4X
4X
Keypad
1 button
on/off
Zero
Front zero
pot.
1 button
on/off
Front zero
pot.
Calibration
Units
Front zero,
Factory set
span pots.
Red LED
1 button
on/off, zero, Hold button
cycle through at startup
min/max
1 button
on/off, zero, Hold button
cycle through at startup
min/max
Options
See options list
_______________
Memory
Shutoff
none
Factory set to 5 minutes
-5
-10
-30
-ON
5 min., factory set
10 min., factory set
30 min., factory set
on/off, factory set
Front zero,
span pots.
Factory set
none
Internal
buttons
Factory set
Min/max
Factory set
-5, -10, -30, minutes or
-1H, -2H, -3H hours
-ON, or desired time
Internal
buttons
Internal
button
select
Min/max
Internal button select to
desired minutes or hours or
continuous on
Red LED
Red LED
4X
4X
To Order
Range
Auto Shutoff Time
See range table
Default for F18, F20, F22
_______________
_______________
3 button
on/off,
zero/clear,
, 
Keypad zero Keypad with
4 or 6 max
Keypad select
button
pass code
readings
Keypad select to desired
minutes or hours or
continuous on
3 button
on/off,
zero/clear,
, 
Keypad zero Keypad with
Keypad select
button
pass code
Keypad select to desired
minutes or hours or
continuous on
Min/max
CEC-8C
8/31/2010 10:27:36 AM