BOROUGH OF POINT PLEASANT INSPECTION REQUIREMENTS A building or structure shall not be used or occupied in whole or in part until the Construction Official has issued a form Certificate of Occupancy. CONSTRUCTION HOURS IN RESIDENTIAL AREA: 8:00 A.M - 6:00 P.M MONDAY THRU SATURDAY. NO CONSTRUCTION IS ALLOWED ON SUNDAY. A port-a-john must be on the construction site prior to commencing work and removed immediately upon completion of the job. Inspections will not be conducted unless a building permit is posted on the building and a set of approved plans is on site. For new construction, water and sewer connection fees must be paid in the Water/Sewer Dept. prior to your first plumbing inspection _ _ Footing - excavation, reinforcing prior to pouring. Some jobs have monolithic pour where concrete slab & footings are poured together. If so, rough slab plumbing and/or electric must be inspected if in slab prior to building inspection _ _ Foundation - foundation constructed, coved, pressure sill anchored; waterproofed prior to backfill. If slab, ducts or piping installed. FOUNDATION LOCATION SURVEY MUST BE SUBMITTED PRIOR TO INSPECTION BEING SCHEDULED _ _ Open Deck - except for basements _ _ Sheathing - New construction; no roof shingles or windows Additions; roof shingles and windows to be installed HEIGHT CERTIFICATIONS REQUIRED FOR ALL ADDITIONS & NEW CONSTRUCTION WHERE A SECOND FLOOR IS CONSTRUCTED _ _ Framing - Complete structural framing, including non-bearing walls, subfloor sheathing, installation of duct work and/or heating pipes, and all ducts to be insulated and all pipes exposed to be insulated. Exterior complete and water tight. Vents and/or chimneys to be installed; all hot air ducts to be installed. Framing checklist to be completed and given to inspector at the time of inspection. ROUGH PLUMBING, FIRE & ELECTRICAL INSPECTIONS MUST BE APPROVED PRIOR TO FRAMING INSPECTION BY THE BUILDING INSPECTOR __ Insulation - Must be irr accordance with the Energy Conservation Code _ _ Final - All utility meters set, general compliance of plans as to type of construction. Basic items of finishing, i.e., sheetrock and other items of wall covering, doors, roof and side wall materials, ventilation, any items that bears on the structural integrity of building, finished floor. General good workmanship. Heating installation, all exterior openings enclosed, all exterior parts protected from elements. FINAL PLUMBING, FIRE & ELECTRICAL INSPECTIONS MUST BE APPROVED PRIOR TO FINAL BUILDING INSPECTION FINAL AS-BUILT PLANS AND SURVEY TO BE SUBMITTED FOR ALL NEW CONSTRUCTION Inspector's Schedules: (732) 892-7129 referring to block/lot number, address or permit number for next available date. Building: Mon. - Fri. Plumbing: Mon. - Fri. Fire: Mon. & Thurs. Electric: Mon., Wed. & Fri (after 11:30 am) Permits in conjunction with Planning Board or Zoning Board approval (subdivision & site plans): Refer to Ernie Peters, Remington, Vernick & Vena (732-286-9220) for required inspections and Ocean County Soil Conservation District: 609-971-7002 BLOCK:~~ LOT. FRAMING CHECKLIST Instructions: Builder 01· Sullcler's ruprosantatJve chacks l;loxes n1arl~ad 13'. SullcHng Inspector cilecl~s boxes 1narked ip. Rusponslbla Person In Churga of Work sluns, lnltfalu and data.a In spaces provided. BuUdlng ll_1spector Initial~ and dates In spacen, provided. 4 NoTFO:: All /'ff:/'v/S SHOUlb EJE; AS SHOWN orv THE: PL.ANS OF? AS F?E:QU!RE:b EJY CODE:. A. BASEMENT OR CRAWL SPACE 'I. ANCHORAGE: 2. SILL PLATES: BOLTS [fil [j [fil [j SPACING SIZE STRAPS [jj] [j lfil [j SPACING (PER MANUFACTURER'S SPECS) SIZE [fil [) [fil [j [ill DJ [fil DJ [fil [j lli] [] [[j 3. BEAM POCKETS: [fil [j] [fil [j] SIZE GRADE, SPECIES 4. BEARING/SHIMS TERMITE PROTECTION OR CLEARANCE TREATMENT LAPS SILL SEALER COLUMNS: [fil ITJ [ij] [[] [ij]_[[] ATTACHMENT /PLATES [El [[] PAINT /COATING SIZED Pm PLAN SPACING/LOCATION PROPER TREATMENT OVER FOUNDATION OPENINGS (BEARING OF JOIST) m TERMITE PROTECl!ON B. Fl~OOR FRAMING AND FLOORING 1. Box OR RIM JOIST, OR PERIMETER BAND JOIST: 2"" 1"' 3"" 4TH lfil DJ [ill [j [fil ITJ lfil [[] [ijJ DJ [ijJ DJ lfil [[] [fil OJ [JjJ [[] [ij] ITJ [[j [iJ [fil DJ [Q] [jJ [ij] [iJ [ij] [iJ [ij] [jJ lfil [[] [ij] [jJ [ij] DJ OD [i] zi-m 31u.1 4n1 GRAOE, SPECIES SINGLE OR DOUBLE , PRE-ENGINEERED PER MAN· FACTURER'S SPECS CANTILEVERS AS PER DESIGN [jj] [i] [ill [iJ [fil [i] FLOOR JOIST: TO THE PLAN [ij] DJ NAILING @J ArrACHMENT SCHEDULE [ij] [[] BEARING [ij] DJ LAPPING m 5. FLOOR PANEL SPAN, THICKNESS [ij] IT! [ijJ [[] [JjJ IT! [JjJ [j] [ij] IT! [fil [! [ij] [[] [ij] [j] DTI OJ OD IT! [ij] DJ [JjJ DJ [ij] [[] [JjJ DJ lliJ DJ 0 [[] [JjJ DJ [JjJ DJ [BJ DJ 0 OJ [JjJ [j] [JjJ DJ 0 IT! [ijJ DJ [fil [iJ [JjJ DJ 0 IT! [[] [j] [JjJ IT! [ij] ITl [ill [[] ill] IT! FLOOR SIZED PER PLAN GRADE, SPECIES PRE~ENGJNEEHED COMPONENTS AS SPECIFIED Bl;ARlNG NAILING BRIDGING CUTTING AND NOTCHING (AS PER GODE) POINT LOADS - SUPPORTED AS PER PLAN SPAN HANGERS HEAOEl~S FRAMED OPENINGS STAIR ATTACHMENT: 1ST 2~1D lfil DJ @] [i] MATERIAL I.ill DJ 3. GIRDERS AND BEAMS: 3rio [ij] DJs1zED PER PLAN 2"b 4TH 1'" [ii] DJ [fil IT! [JjJ [[] [ii] [j] [ij] [[] TYPE [ij] DJ [JjJ DJ [JjJ [[] [ii] IT! [ij] DJGRADE, SPECIES [ij] [[] LOCATION ANO RELATION [JjJ DJ ill] OJ [JjJ DJ [JjJ DJ SIZE 4. FLOORING, SHEATHING, OR DECKING: 1" 2. FLOOR [i[J DJ [fil [i] 3"" OTI DJ OTIDJ 41H [JjJ [iJ [JjJ [iJ FLOOR BEARING NAILING SPECJAL REQUIREMENTS [JjJ DJ [fil IT! [fil [j] [fil IT! [ill DJ [ij] DJ [ij] [[] [ij] DJ OIJ IJ] ill] OJ [[J IJJ U.C.C. F390-1 (rev. 03!09) lliJ fJJ EDGE BLOCKING (IF REQUIRED) GAPPING LAYOUT cl·iecl~lls,t I ! l1ereby certify tl1Bt I Inspected t11!s bufldf11g using... U1ls and It conf(lrrrnJ tq tl'le released plans lllld to t~1e requlren1ente oft!·1e Unlfonn Construr.tfon !,.,ode, N.,l.A.C..·. 5;23. Hesponslble Person !11 Ct1arge of Worlc - - - - - - - - - - - - - - Date:~------ 11 Bul.l~ifn.n lnspec!or lnlt1dls . _ _ __ Dale: _ _ _ __ PERMIT# LOT. BLOCK: C. WALL FRAMING 1. EXTE:RIOR WALL FRAME:: 3110 '! !lT 4;rn 2"" FLOOR llil [i] llil [i] [[] [i] [[) [iJ ITI llil ITl llil ITl llil ITl llil lliJ [D OD [i] OD f±l III IJJ ([] OJ OD 1JJ III III IJJ III IJJ OD ITl III ITl ITO IJJ llil DJ ITO OJ llil OJ ITO OJ 1. SIZE SPACE SPECIES AND GRADE CUTTING, NOTCHING AND 80RJNG HEADER SIZES JACI.< STUD SEARi.NG TOP PLATES llil ill OD DJ llil OJ OD DJ ITO [i] III IJJ OD IJJ OD [i] lil IJJ [fil [j] NAl.LING llil IJJ [[J [j] ·LAPS llil IJJ OD [j] RAFTER TIES STRAPS llil IJJ [fil [jJ HURRICANE (AS REQUIRED) 0. ROOF FRAMING 1. Thuss ROOF FRAMING (As PE:R DESIGN): APPROVED DOCUME:NlS WHICH SHOW: lliJ [i] LAYOUT PLANS . lliJ [JJ TRUSS MEMBrns [ill IJJ CONNECTION SCHEDULE @] [] [ill OJ 2. INTERIOR LOAD-BEARING WALLS: llil [i] [fil [fil OJ [fil IJJ [fil [ill OJ llil ill [ill @J Ql IIJ IIJ [j] llil ill lil OJ llil ill llil DJ lliJ III ffi I III OJ llil [iJ llil IJJ [ill IJJ lill IJJ lill III llil [i] lil DJ lill m ITiJ III lill DJ llil DJ . [fil 1ST SIZE SPACE .LAYOUT-SUPPORT BELOW PER CODE SPECIES AND GRADE CUlTING, NOTCHING AND BORING FIRE BLOCKING I-I EADER SrzEs 2"" 3"' 4'" [fil [j] @:] [j] [ijJ OJ [fil [j] IIJ OJ llil [j] llil [j] @] [j] [ijJ III [fil [JJ [fil [JJ llil [JJ [fil OJ [ill OJ [fil OJ [[] ill [fil wllil III III [fil OJ llil ill lliJ [JJ [fil [ill ill llil OJ [ill OJ llil III [fil [JJ llil III FLOOR SIZE SPACE SPECIES AND GRADE CUTIING, NOTCHING AND BORING FIRE BLOCKING HEADER SIZES .TOP PLATE NAILING JACK STUD BEAR.ING NAILING LAPS STRAPPING 2. PERMANENT Thuss-To-Thuss BRACING (As PE:R DESIGN): [fil OJ [fil III [jjJ [j] llil [j] [ij] ill llil III Ilil III @]ill EQUIPMENT/ APPLIANCES ON MANUFACTURER'S DRAWINGS III SIZE OD ill GRADES, SPECIES LAYOUT OD [JJ SPACING SIZE TYPE NAILING · [ijJ [jJ SPAN [ijJ [i] BEARING OVERLAP TtRMINATION ThANS!T!ON (I.E., CROSS) BRACING 3. GABLE END BRACING (AS PE:R DE:SIGN): ITiJ [j] ITiJ [j] OD III llil [iJ llil [j] llil ill LAYO UT SIZE TYPE NAILING OVERLAP 4. SOLID SAWN ROOF FRAMING: [jJ l_AYOUT OD III FASTENING [fil III DAMAGE CAUSED BY FASTENERS (RAFTERS NOT SPL!T BY TOENAILS) Oii [J] CUlTING, NOTCHING, AND BORING [ijJ III BRIDGING III [JJ RIDGE SIZE [fil>III 1-JURRICANE TIES WHERE APPLICABLE TERMINATION SHEATHING 1. SHEATHING - EXTERIOR WALLS: 2. SHEATHING - Roop: MATERIAL MATERIAL @:] [j] OJ llil OJ lfil OJ lill OJ ~ ill n 3. INTERIOR NoN-LOAb·BEARING.WALLS: FLOOR TOP PLATES MANUFACTURER'S DRAWINGS E. 4.Tfl :;l"" llil III llil III llil III lil III lill ITl llil DJ STRUCTURES ON lli] [iJ LOCATION AS PER LAYOUT @] IJ] ALIGNMENT [i\J [j] BEARING @J OJ SPACING lli] OJ CONNECTIONS TO BEARING POINTS [ill OJ No CONNECT!ON TO NON-BEARING POlNTS lli] [i] DAMAGE AND DEFECTS fli] DJ ENGINEERED METHQD OF' REPAIR OJ ffiJ [j] llil III llil OJ lfil OJ llil DJ PERMANENT BRACING DETAILS DORMERS/!~OOF 2'" '!ST PANEL SPAN, THICKNESS SPECIAL REQUIREMENTS [ill OJ GAPPING lli] OJ [EJ OJ U.C.C. F390·2 (rev. 03/09) [fil III SHEATHING, FRT- ROciF llil III [[] OJ PANEL SPAN, THICKNESS SPECIAL REQUIREME:NTS LAYOUT CORNER BRACING (!F REQUIRED) [fil OJ fill OJ 8LOCKJNG, EDGE (IF' REQUIRED) CLIPS (IF REQUIRED) Initials: Hs~p Pflrntln 1n Charga of Wo1I( FOUR FEET FROM FIREWALL NONCORROStVE FASTENERS [fil ITJGAPPING [fil IJJ LAYOUT G11lldlnu tnspoclor
© Copyright 2026 Paperzz