Integrating New Holland PLM with Raven & Rawson Controllers Raven SCS 100 Series: 440/450/460/660 Raven SCS 1000 Series: 4000/4400/4600/5000 Rawson Accu-Rate Control System Category: Precision Land Management Series/Model: Integrating New Holland PLM with Raven & Rawson Controllers Document: PLM-10003-09 Date: January 2009 Precision Land Management This is a Sale Education document not to be used for advertisement. Specifications Third Party Controller Capability Raven and Rawson Rate Controllers New Holland Precision Land Management products may be used in conjunction with Raven and Rawson variable rate controllers. Specific cables are available through New Holland Parts to communicate with Raven/Rawson controllers through the DB9 port and Tyco port of the IntelliView Plus II display. New Holland offers an operator’s manual for both third party controllers through the Document Management Center. Please refer to “Raven Variable Rate Software for IntelliView Plus II Display” operator’s manual for display set up and operation (87472173). Refer to “Rawson Accu-Rate Control System Software for IntelliView Plus II Display” operator’s manual for display set up and operation (87472174. An important step prior to selecting the appropriate cable is to determine if the vehicle is IntelliSteer ready. If it is not IntelliSteer ready or a non-New Holland vehicle a separate harness is required. Additionally, a power source such as an auxilary fuse will suffice. Compatible Models - Raven The following Raven systems are supported using an RS-232 serial connection in conjunction with the data menu settings listed in the chart below. • SCS 100 series: 440/450/460/660 and other variants • SCS 1000 series: 4000/4400/4600/5000 and other variants Function Baud Rate Trigger Value Trigger Units GPS Functions Decimals Data Direction* Datalog Mode* Variable Rate Control** Setting 9600 1 1 sec Disabled Unshifted Com port Console Data On *4400/4600 models only **4400/4600/5000 models only A null modem serial cable is required to connect to the Raven Control System to the IntelliView Plus II display. Raven Part Number • • 115-0159-624 for the Raven 100 series 115-0171-395 for the Raven 1000 series Specifications IntelliView Plus II Required Software Raven • Raven Controller 16.1.0.0 • Com3 Manager 16.1.0.0 • As Applied 16.2.0.0 • Precision Farming 16.2.0.0 • Generic Tractor 16.2.0.0 or Large Tractor 16.1.0.0 • Framework 16.4.0.0 Rawson • Rawson Controller 16.1.0.0 • Com3 Manager 16.1.0.0 • As Applied 16.2.0.0 • Pecision Farming 16.2.0.0 • Generic Tractor 16.2.0.0 or Large Tractor 16.1.0.0 • Framework 16.4.0.0 New Holland Tractor Compatibility by Serial Number and IntelliSteer Option New Holland Tractor Serial Break - IntelliSteer Ready Model T7000 T8000 T9000 Serial Number Z6RW04319 and above Z6RW04319 and above Z7F202169 and above Harness Part Number 87732647 87732647 87732647 New Holland Tractor Serial Break - Non-IntelliSteer Ready* Model TG/T8000 TJ/T9000 Serial Number Z6RW01001 - Z6RW04319 Z6RW01001 and below Z6F200013 - Z7F202169 Z6F200013 - and below Harness Part Number 84169716 84169716 84169716 84169716 *Must install appropriate ISO11783 harness, mounting brackets and IntelliView Plus II display on New Holland tractors not equipped IntelliSteer ready from factory in addition to listed harness. Note - if auto guidance is not desired, the steering sensor, hydraulic manifold and hoses are not required to be installed. Specifications Communicating with third party variable rate controller via IntelliView Plus II IntelliSteer ready tractor OR OR Rawson Accu-Rate Com Port A Com Port B (DB9 male connection) (DB9 male connection) Harness p/n 87732647 Raven SCS 1000 series 4000/4400/4600/5000 Raven SCS 100 series 440/450/460/660 *Both female com ports are found on the third party controller IntelliView Plus II Tyco Connector *Plugs into IntelliView Plus II. This is com port A - RS232 14 *Wires must be insterted into appropriate cavity in Tyco connector. This is com port A - RS232 10 13 Com Port *DB9 female connection found next to Amp connector on IntelliView Plus II. This is com port B - RS232 *If using IntelliSteer auto guidance, tractor must have NH162, NH252 or NH262 receiver and NAVII controller installed per manufacturer specification. Auto guidance must be configured through IntelliView Plus II display. Specifications Communicating with third party variable rate controller via IntelliView Plus II • Non-IntelliSteer ready New Holland tractor • New Holland vehicle using an IntelliView Plus II display with an NH100, NH162, NH252 or NH262 *If using IntelliSteer auto guidance, tractor must have NH162, NH252 or NH262 receiver and NAVII controller installed per manufacturer specification. Auto guidance must be configured through IntelliView Plus II display. Power Supply Switched 12V + and clean ground. *Not used in this application IntelliView Plus II GPS Connection Metripack female connector to GPS harness Diagnostic Port Connector CAN Terminator Harness p/n 84169716 Connects CAN, 12V+ and clean ground Com Port Tyco Connector *Plugs into IntelliView Plus II. This is com port A - RS232 Com Port *DB9 female connection on IntelliView II. This is com port B - RS232 Clean ground connection *DB9 male connection on rate controller. This is com port A - RS232 Com Port *DB9 male connection on rate controller. This is com port B - RS232 *Both female com ports are found on the third party controller OR Rawson Accu-Rate OR Raven SCS 100 series 440/450/460/660 Raven SCS 1000 series 4000/4400/4600/5000 Specifications Communicating with third party variable rate controller via IntelliView Plus II • Non-New Holland vehicle using an IntelliView Plus II display with an NH100, NH162, NH252 or NH262 Power Supply Switched 12V + and clean ground. Must be wired to 12V source such as auxillary fuse panel or cigarette lighter *If using a NH100, NH162, NH252 or NH262 receiver measurements must be recorded and entered into IntelliView Plus II display. IntelliView Plus II GPS Connection Metripack female connector to GPS harness Diagnostic Port Connector CAN Terminator Harness p/n 84169716 Connects CAN, 12V+ and clean ground. *Not used in this application Com Port Tyco Connector *Plugs into IntelliView Plus II. This is com port A - RS232 Com Port *DB9 female connection on IntelliView II. This is com port B - RS232 Clean ground connection *DB9 male connection on rate controller. This is com port A - RS232 Com Port *DB9 male connection on rate controller. This is com port B - RS232 *Both female com ports are found on the third party controller OR Rawson Accu-Rate OR Raven SCS 100 series 440/450/460/660 Raven SCS 1000 series 4000/4400/4600/5000 Notes Additional Notes ________________________________________________________________________________ ________________________________________________________________________________ ________________________________________________________________________________ ________________________________________________________________________________ ________________________________________________________________________________ ________________________________________________________________________________ ________________________________________________________________________________ ________________________________________________________________________________ ________________________________________________________________________________ ________________________________________________________________________________ ________________________________________________________________________________ ________________________________________________________________________________ ________________________________________________________________________________ ________________________________________________________________________________ ________________________________________________________________________________ ________________________________________________________________________________ ________________________________________________________________________________ ________________________________________________________________________________ ________________________________________________________________________________ ________________________________________________________________________________ ________________________________________________________________________________ The information presented herein is intended for sales education purposes and is intended for the use of CNH Global N.V., its affiliates, and its independent dealers only. This information is to be treated as CONFIDENTIAL and is not to be used for advertising purposes. Competitive comparisons are based on competitive information known at time of printing. Sources of information include published industry specifications and data. General statements made herein are the opinions of the authors concluded from supporting data. Note: Specifications are stated in accordance with industry standards or recommended practices, where applicable. Any trademarks referred to herein in association with the goods and/or services of companies other than CNH Global N.V. are the property of these respective companies. New Holland is a registered trademark of CNH Global N.V. This Sales Education Document has been published for worldwide circulation. The availability of some models and equipment builds vary according to the country in which the equipment is used and sold. The illustrations and text may include optional equipment and accessories and may not include all standard equipment. For more information about the current standard and optional equipment offered for your sales area, consult the published price listings. Important CNH Global N.V. reserves the right to change product specifications without notice and without incurring any obligation relating to such changes. CNH ORIGINAL PARTS ENGINEERED FOR NEW HOLLAND EQUIPMENT. SUPERIOR QUALITY, GLOBAL SUPPORT. COM-10002-08 © 2008 CNH Global N.V. All Rights Reserved. Printed in U.S.A. www.newholland.com
© Copyright 2026 Paperzz