Wiring Instructions for Class 1 LED Power Supplies to LED Modules Installation Guide Wiring Block Diagram RED (V+) BLACK (V-) AC INPUT (3*AWG #18) DC OUTPUT (2*AWG #18) LED Module Class 1 Power Supply Types • LED modules MUST be wired in multiple strings. • Number of modules per string cannot exceed the maximum specified below. • Total number of modules per power supply are specified below. 100W Power Supply Load Chart 100W 150W DC OUTPUT (2*AWG #18) AC INPUT (3*AWG #18) 220W LED Module Maximum # of Modules per String Total # of Modules Maximum # of Modules per String Total # of Modules Maximum # of Modules per String Total # of Modules BASE CORE APEX CORE XTRA APEX XTRA COLOR (R,G,B) COLOR (Y,O) MINI 120 120 36 60 48 120 120 120 208 208 56 100 75 187 136 268 120 120 36 60 48 120 120 120 313 313 83 150 113 281 205 402 120 120 36 60 48 120 120 120 458 458 122 220 165 412 300 589 RED (V+) BLACK (V-) 150W AC INPUT (3*AWG #18) DC OUTPUT (2*AWG #18) L (BLK) INP UT 100-277 VA C MAXIMUM DISTANCE* Wire Gauge (AWG) STANDARD (ft) 18 18 16 29 14 45 12 71 10 120 METRIC (m) 5.5 8.8 13.7 21.6 36.6 Power Distribution Block V+ (RED) L E D P o we r S u p p l y PS12-150W-100-277V I nput V ol t age E345769 I nput Current N(WHT) (GRN) C u sto me r Se rvi ce :1 -8 6 6 -4 8 2 -0 2 0 3 C onstant Voltage Type 100-277 V A C 50/ 60 Hz Output V ol t age 11.4-12.6DC Output Current 0-12.5 A DC 1.75 A @ 100V A C tc:90°C For dry, damp and wet locations 12 V DC V- (BLK) RED (V+) BLACK (V-) DC OUTPUT (2*AWG #18) AC INPUT (3*AWG #18) L (BLK) General LED ,Inc. INP UT 100-277 VA C V+ (RED) L E D P o we r S u p p l y PS12-220W-100-277V E345769 I nput V ol t age I nput Current N(WHT) C u sto me r Se rvi ce :1 -8 6 6 -4 8 2 -0 2 0 3 C onstant Voltage Type tc:90°C 100-277 V A C 50/ 60 Hz Output V ol t age 2. 8 A @ 100V A C Output Current 11.4-12.6DC OUTPUT 12 V DC 0-18.33 A DC For dry, damp and wet locations V- (BLK) RED (V+) BLACK (V-) Troubleshooting Problems All LED modules are OFF or some of the LED modules are not illuminated Entire section does not light or lights intermittently LEDs flicker or appear dim *Distance from power supply to first LED module of the string (at full capacity) General LED Power Supply Possible Causes 1. No power to power supply 2. Wrong voltage power supply 3. Bad/Loose connection 4. LED modules connected in reverse polarity 1. Bad/Loose/Improper connections 2. Power supplies spaced too close together 1. Power supply may not be loaded properly with LED modules 2. Power supply may be damaged or defective. • The maximum case temperature shall not exceed 88ºC when used in end product. • The maximum leakage current measured from the metal enclosure is 0.76 mA. This needs to • These products are intended for use in dry and damp locations. • These products are intended to be connected to a max. 20 A branch circuit. be considered if the end product is cord and plug connected. AgiLight, Inc., a Division of General LED, Inc. +1.866.482.0203 OUTPUT 220W (GRN) Jumper Wire Gauge Chart General LED ,Inc. www.AgiLight.com www.GenLEDLighting.com www.GeneralLED.com WARNING RISK OF ELECTRICAL SHOCK Turn OFF power before perfoming any maintenance. © 2013 General LED, Inc. 2013 All rights reserved. Product Specifications subject to change without notice. 02-2013
© Copyright 2026 Paperzz