P.C. Board Mount (601

P.C. Board Mount (601-610 Series)
• These ferrite cored transformers are fully encapsulated in a high grade black molded case with a UL94V-O rating.
• Used in digital and data processing, line coupling, matching, isolation etc.
• Working voltage rating maximum of 500V D.C.
• ET values up to 50V uS.
12.7
1:01
1:01
1:01
1:01
1:01
1:01:01
1:01:01
1:01:01
2060
492
219
50
9.5
2060
492
219
2
6
4
12.7
10.16
2
5
6
Inter W
Capacity
pf. Ref.
Leakage
Inductance
uH (max.)
45
20
12
10
10
35
20
12
0.6
0.3
0.25
0.2
0.2
0.6
0.3
0.25
1
Sec. 2
D.C.
Cir.
Resistance
Dia.
Ohms max.
1.5
0.8
0.5
0.4
0.4
1.5
0.8
0.5
B
B
B
B
B
C
C
C
2
3
4
5
6
Primary
1
5
3
Sec. 1
Diagram B
2.5
NOTES:
- All dimensions in mm
- Pins 3 & 4 are omitted on
circuit diagram A & B units
Primary
ET
Constant
V
uS
17.5
8.5
5.5
4
6
17.5
8.5
5.5
1
8.89
Pin Dia. 0.56
6.35
601A
601B
601C
601D
601F
602A
602B
602C
Primary
4.3
Primary
Inductance uH
(min)
Secondary
PULSE TRANSFORMERS
Part
No.
Turns
Ratio
+/- 2%
Diagram C
5.08
610A Dimensions & Schematic
11.4
12.7
3
2
11.4
7.6
4
1
Primary
7.6
1
3
2
4
Secondary
9.1
Note: All dimensions in mm
610B Dimensions & Schematic
11.4
12.7
7.6
11.4
1
Primary
Pulse
6.4
6 5 4
1 2 3
3
3.8
2
4
5
Secondary
12.7
PULSE TRANSFORMERS
6
Note: All dimensions in mm
Part
No.
Ratio
610A
610B
1:01
1:01
Secondary
Resistance
Primary
Inductance
mH (min)
3.9
2.7
Resistance
Ohms
3.4
2.1
Sec. 1
(Ohms)
3.9
2.1
Sec. 2
(Ohms)
2.3
• These ferrite cored transformers are fully encapsulated in a high grade black molded case with a UL94V-O rating.
• Units are intended for wide band and pulse applications including thyristor / triac firing circuits.
• Peak pulse voltage rating maximum of 250V.
• Insulation tested to 1,000V RMS.
Primary
ET
Constant
V
(uS).
500
500
CANADA
©
60
50
Max. Primary or
Secondary
Peak Current
@ 10%
@ 1%
Duty
Duty
0.2A
0.6A
0.2A
0.6A
EUROPE
Guelph, Ontario (519) 822-2960
St. Laurent, Quebec (514) 343-9010
www.hammondmfg.com
Cheektowaga, NY (716) 630-7030
104
USA
Leakage
Inductance
uH (max.)
Basingstoke, UK 01256 812812
AUSTRALIA
Queenstown, Australia 61-8-8240-2244
P.C. Board Mount (610-611 Series)
1
PRI
NOTES
- Pins 0.8 or .64 squar e
- Dot above pin 1
- All dimensions in mm
- Pin 3 & 4 exists on 610BB & C
5
2
6
Fig. A
15
3
PRI
15.8
1
S. 1
4
5
2
6
S. 2
6
Fig. B
10.2
4
5
6
PULSE TRANSFORMERS
10.2
2
3
• These ferrite cored transformers are fully encapsulated in a high grade black molded
case with a UL94V-O rating.
• Units are intended for wide band and pulse applications including thyristor / triac firing
circuits, signal isolation, line matching, low power switch mode power supplies, etc.
• Working voltage rating maximum of 500V RMS
• All units are voltage proof tested to 2.0KV peak 50 Hz.
5.1
1
Part
No.
Ratio
610AA
610BB
610C
1:01
1:01
2:01
Primary
Inductance ET Constant
mH (min)
V (uS)
3
200
3
200
12
400
Leakage
Inductance
uH (max)
22
9
35
Capacity
pf. (Ref)
23
28
30
D.C. Winding Resistance
Pri
Sec. 1
Sec. 2
(Ohms)
(Ohms)
(Ohms)
1.2
1
1.4
1.3
1.7
4
1.8
2.4
Sch.
Fig
#
A
B
B
611A & 611C
611B & 611D
611B
PULSE TRANSFORMERS
611D
• Economical, open style, P. C. board pin mount
• Units are intended for pulse applications including thyristor / triac firing circuits.
611A
611B
611C
611D
Ratio
Circuit
Max.
volts
Primary
ET
Constant
V (uS)
1:01
1:01
1:01
1:01
125
125
250
250
1400
1400
7250
4000
Part
No.
611A & 611B
611C & 611D
D.C. Winding
Resistance
Primary
Inductance
mH (min)
8.6
17.2
56
17
Pin Spacing
0.2” x 0.6”
0.2” x 0.6”
D.C. Res.
(Ohms)
0.45
1.26
3.31
1.73
Sec. 1
(Ohms)
0.55
1
4.46
1.31
Height Width
.69”
.82”
.82”
1.06”
Sec. 2
(Ohms)
1.53
2.12
Coil
Depth
.57”
.82”
EUROPE
Basingstoke, UK 01256 812812
AUSTRALIA
Queenstown, Australia 61-8-8240-2244
Max. Primary or
Secondary Peak
Current
@ 10%
@ 1%
Duty
Duty
0.7 A
2.1 A
0.7 A
2.1 A
0.7 A
2.1 A
0.7 A
2.1 A
Insulation
RMS
(Volts)
Wt.
Oz.
1000
1000
1500
1500
0.7
0.7
1.2
1.2
Pulse
Part
No.
Mounting Tab
Centers
Size
1”
.12” x .25”
CANADA
www.hammondmfg.com
Guelph, Ontario (519) 822-2960
St. Laurent, Quebec (514) 343-9010
105
Cheektowaga, NY (716) 630-7030
USA
©