SYSTEM High quality generating sets with Volvo Penta diesel engines are prepared for both: continuous and emergency operation after mains supply failure. They feature low fuel consumption, high durability and lowest operating costs. Designed for emergency power supply in case of mains supply failure or disruption as well as for autonomous electric power source. Sets available from 94 to 700 kVA units. kVA 385 STAND-BY ACTIVE POWER kW 308 PRIME POWER kVA 350 PRIME ACTIVE POWER kW 280 NOMINAL CURRENT A 505,8 VOLTAGE AVAILABLE V 400/231 STEADY VOLTAGE PRECISION % 1 RATED FREQUENCY Hz 50 % 0,5 TYPE POWER mm 3230 WIDTH mm 1140 HEIGHT mm 1885 WEIGHT kg 3010 TAD1342GE l 650 dB - NOISE kW/hp 333/452,5 No.OF CYLINDERS, ARRANGEMENT - 6L ASPIRATION TYPE - TURBO INTERCOOLER TOTAL DISPLACEMENT l 12,78 ENGINE OIL CAPACITY 36,0 COOLING TYPE l - LIQUID COOLANT CAPACITY l 44,0 rpm 1500 SPEED GOVERNOR - ELECTRONIC WIRING VOLTAGE V 24 FUEL CONSUMPTION at 75% load l/h 54,00 FUEL CONSUMPTION at 100% load l/h 71,20 ROTATION SPEED ALTERNATOR LENGTH FUEL TANK - CANOPIED VERSION - GV 385 S Silenced according to Noise Directive 2000/14/WE with amendment 2005/88/WE GV 385 S VOLVO ENGINE FREQUENCY TOLERANCE OPEN VERSION - GV 385 GV 385 STAND-BY POWER LENGTH mm 4100 WIDTH mm 1600 HEIGHT mm 2615 kg 3995 l 700 dB(A) approx. 70 TYPE - ECO 38-3LN/4 PROTECTION RATING - IP 21 REACTANCE Xd” % 9,4 WEIGHT THDu % 2,9 FUEL TANK - H MECC ALTE INSULATION CLASS EPS SYSTEM Systemy Zasilania Awaryjnego ul. Harcerska 16, 32 - 540 Trzebinia tel. +48 32 623 66 88, fax +48 32 623 69 53 www.epssystem.pl, e-mail: [email protected] NOISE LEVEL AT 7 m ver. 07.01.11 PROJECT & INSTALLATION DATA FOR GENERATING SET GV 385 OPEN RADIATOR HEIGHT mm 900 RADIATOR WIDTH mm 925 RADIATOR-BASE DISTANCE mm 707 MIN. SURFACE OF AIR INLET m2 1,000 MIN. SURFACE OF AIR OUTLET m2 0,83 EXHAUST PIPE DIAMETER mm MAX CABLE CROSS-SECTION mm 2 CANOPIED 108 108 2x150 2x150 Details above enable to project air circulation system in a premises designed for generating sets fitting. Exact size of air inlet and outlet as well as cable cross-section should be selected with taking gen-set location under consideration. For open sets - outer radiator dimensions, pipe diameter exhaust coupler - muffler. For canopied sets - outer dimensions of air outlet fitted in the canopy. Stand-By power ( STAND-BY/LTP acc. to PN-ISO 8528) -power of the set using for emergency power supply; maximum power available for a period of 500 hours/year with varying loads. No kind of overload is permissible. Prime power ( PRP acc. to PN-ISO 8528) -maximum power available with varying loads for an unlimited number of hours. A 10% overload is permissible for 1 hour every 12 hours of operation. STANDARD OUTFIT Engine and generator Steel frame with vibration damping system Cooling system and radiator Ignition battery, wiring system Fuel tank, fuel system Exhaust muffler and coupler-separated Generator main switch Control panel Open generating sets are to be put into premises or containers. Canopied versions are resistant to weather and can be installed outside. Control panels types: - manual control panel; -automatic control panel (turns on sets with volt-free contact); - transfer switch panel with ATS (Automatic Transfer Switch) Automatic versions are normally equipped with engine block heater and battery charger. Oil drainage pump CANOPIED SETS ADDITIONAL EQUIPMENT Varnished steel canopy Muffler fitted in a canopy Easy access lockable door Window for reading control devices External emergency stop button For more information about control panels see details in separate auxiliary laeflets. Further information about canopies and gen-set installation are available in additional booklets. OPTIONS: - container canopies made of steel, concrete or prefabricated; - certified towing trailers; - differential current switch; - 1 and 3-phase fused sockets; - remote monitoring system of operation; - volt-free contacts for operating conditions signalling; - engine block heating system; - battery charger; - enlarged basic fuel tanks; - external fuel tanks with re-filling system; - muffler with enhanced attenuation degree; - many canopy colours available(standard blue RAL 5010). Our products are constantly modified, so their appearance as well as some parameters may be slightly different to those enclosed in this leaflet. Presented photographies are only for example EPS SYSTEM Systemy Zasilania Awaryjnego ul. Harcerska 16, 32 - 540 Trzebinia tel. +48 32 623 66 88, fax +48 32 623 69 53 www.epssystem.pl, e-mail: [email protected] ver. 07.01.11
© Copyright 2026 Paperzz