ADORA DRii - TECHNICAL SPECIFICATIONS 14200246 ADORA DRi Technical Specifications v. 4615 Page 1/18 Contents 1.0 Adora RAD system .............................................................................. 3 1.1 Ceiling Tube & Detector Positioner ........................................................... 3 1.2 Patient table ......................................................................................... 4 1.3 X-ray Generator and Tube ...................................................................... 5 1.4 Collimator ............................................................................................. 5 1.5 DAP meter ............................................................................................ 5 1.6 Primary flat panel detector ...................................................................... 6 1.7 Detector Docking ................................................................................... 7 1.8 Anti-scatter Grids .................................................................................. 7 1.9 User-interface ....................................................................................... 8 1.10 Imaging control software ........................................................................ 8 2.0 Additional portable detectors ........................................................... 10 3.0 Options ............................................................................................. 11 3.1 Automatic Image Stitching .....................................................................11 3.2 inOrbit for iso-center Tracking ................................................................11 4.0 Accessories ....................................................................................... 12 4.1 Ceiling hoist system ..............................................................................12 4.2 Table side hand grips ............................................................................12 4.3 Paper roll holder ...................................................................................12 4.4 Grids for insertion in detector housing .....................................................12 4.5 Grids for click-on to portable detectors ....................................................13 4.6 Grid storage cage .................................................................................13 4.7 Mattresses ...........................................................................................13 4.8 Patient table support stand ....................................................................13 4.9 Patient Grip stand .................................................................................14 4.10 Foot switch ..........................................................................................14 4.11 Auto-positioning button .........................................................................14 4.12 Laser cross ..........................................................................................14 4.14 Foot step .............................................................................................15 4.15 Remote control .....................................................................................15 4.15 Foot switch ..........................................................................................15 4.16 Auto-position foot switch .......................................................................15 5.1 Installation data ...................................................................................16 5.2 Operating environment ..........................................................................17 5.3 Environment ........................................................................................17 6.0 Classification and standards ............................................................. 18 7.0 Revision History ..................................................................................... 18 14200246 ADORA DRi Technical Specifications v. 4615 Page 2/18 1.0 Adora RAD system 1.1 Ceiling Tube & Detector Positioner Image #1. Adora tube and detector are suspended in one ceiling unit rotating around its center suspension axis. The two telescopic arms supporting the X-ray tube and detector can be positioned individually. This facilitates e.g. horizontal projections from each side of the table enabling both right and left axial hip imaging, without repositioning the patient. Type Fully automatic, motorized digital radiographic imaging solution based upon anatomical programme selection. Provides fast and accurate DR imaging from every examination angle through one-touch, stress-free operation. Positioning Up to 999 APRs and associated auto-positions including all examination parameters can be programmed. Handson, power-assisted positioning can be activated at any time, and any adjustment can be made to system defaults when needed. Advanced software monitors all system components in order to avoid collisions. • inMotion tech. The inMotion technology enforces the notion of having a highly flexible system with the capacity for high patient throughput. It offers safe transitions to pre-programmed positions through the auto-position linked directly to the imaging systems anatomical programme selection. 14200246 ADORA DRi Technical Specifications v. 4615 Page 3/18 SmartHandle Automatic operation with smooth, power-assisted movements ensures precise and easy positioning of the detector and tube, even for complex DR examinations. The ergonomic SmartHandle controls up to 3 movements in the X, Y and Z plane at the same time. User interfaces A large 12” floating touch screen on the tube displays and controls the SmartHandle movements, and tilts to keep text horizontal to the user at all times. Short and simple menus and self-explanatory icons guide the user through the DR process. Integrated access to generator parameters; image preview. SID Range 50-200 cm if CXDI-701C docking 50-197 cm if CXDI-401C docking Automatically calculated when detector is docked Manually using built-in measuring tape in portable mode 26-185 cm above floor level @ 300 cm ceiling height 26-169 cm above floor level @ 300 cm ceiling height +/- 120o around vertical axis +/- 120o around horisontal axis +/- 93o around vertical axis +/- 120o around horisontal axis + 90o in Z-axis +/- 270o @ 4-22o/sec. 3-25 cm/sec. in rails Focal spot travel Detector center travel Tube Rotation Detector Rotation Ceiling Unit Rotation Ceiling Unit Longitudinal 1.2 Patient table Image #2. The durable carbon fiber patient table with floating top and 340° rotation around the base ensures easy patient access all around the table, and optimum conditions for examinations in wheelchairs and patient beds. 14200246 ADORA DRi Technical Specifications v. 4615 Page 4/18 Height Adjustment Longitudinal Movement Transverse Movement Center alignment Max load Table Top Size Table Top Material X-ray translucent area Al equivalence 1.3 X-ray Generator and Tube Type Rating kV range kV accuracy mA range mA accuracy mAs range Exposure Time range Anode Heat capacity Focal spot sizes (IEC) Stator Target angle 1.4 Fully DR-integrated, high-frequency (100kHz) 65 kW (optional 80 kW) 40 to 150 Kv 5% + 1 kVp 10 - 800 mA (10 – 1000 mA for 80 kW option) 5% +1.0 mA for all mA values 0.5 - 1000 mAs 1 ms – 6.3 s (pls observe detector limitations) 350 kHU 0.6 - 1.0mm High-speed 12° Collimator Type Rotation Spectral Filtration Collimation Light Field 1.5 51 – 86 cm 56 – 91 cm with 340° rotation option +/- 10 cm manual floating +/- 20 cm manual floating Automatic/manual, motorized 250 kg evenly distributed load 2930 x 700 mm Carbon fibre 2000 x 700 mm < 1.25 mm Fully automatic, motorised with manual override +/- 180o motorised 1.0mm Al + 0.1mm Cu, motorised, pre-programmable 1.0mm Al + 0.2mm Cu, motorised, pre-programmable 2.0mm Al, motorised, pre-programmable Motorized square collimation – pre-programmable or controllable via SmartHandle Timer-controlled after last system movement. Adora system light dims when the collimator light is active DAP meter Type 14200246 ADORA DRi Technical Specifications v. 4615 Page 5/18 Fully integrated; recorded in DICOM file 1.6 Primary flat panel detector Image #3. A strong and expanding range of high quality flat panel detectors from Canon is the cornerstone in Adora system configurations. The Canon detectors and CDXI control software provide fast, high quality, digital image capture on demand and cover an extensive range of radiographic examinations. Adora can be configured with one detector to be used for all examinations (see below for list of primary detectors). In addition to the docked detector, Adora supports up to two portable detectors. Thus, ergonomics and examination flexibility can be further enhanced by adding e.g. a small wireless detector to the configuration (see page 9 for optional detectors). Model Pixel pitch Resolution Scintillator Weight Dimensions Imaging area size Wireless network Battery performance Recharge time Image available time Cycle time Interface Composition 14200246 ADORA DRi Technical Specifications v. 4615 Page 6/18 Canon CXDI-701C Wireless (Portable) 125 microns 2800 x 3408 pixels (9.5 Megapixels) High sensitivity Cesium Iodide (CsI) 3.3 kg incl. battery 38.4 x 46 x 1.5 cm 35 x 43 cm IEEE 802.11 n (2.4 GHz & 5GHz) Max mode: 1200 images (@ 9-second cycle, 1-second sleep), 3 hours; Ave. mode: 140 images (@ 100second cycle, 1-second sleep), 4 hours; Save mode: 6.5 hours @ sleep mode Less than 3 hours Preview image: 3 seconds High-resolution image: Approx. 5 seconds 9 seconds DICOM 3.0, Ethernet 10/100/1000 Mbps CXDI-701C Wireless detector incl. batteries + charger Control PC w. advanced CXDI-NE software preinstalled DICOM Storage, Print Management, Modality Worklist, Performed Procedure Steps (MPPS) DICOM 3.0 compliant. X-ray images are sent to servers using Storage Service Class (SCU) and to printers using Print Management Service Class (SCU). C-echo and Storage Commitment – all as SCU. Model Pixel pitch Resolution Scintillator Imaging area size Image available time Cycle time Interface Composition Model Pixel pitch Resolution Scintillator Imaging area size Image available time Cycle time Interface Composition 1.7 Canon CXDI-401C Compact (Fixed) 125 microns 3320 x 3408 (11.3 Megapixels) High sensitivity Cesium Iodide (CsI) 42 x 43 cm Preview image: Approx.3 seconds High-resolution image: Approx. 5 seconds Approx. 9 seconds DICOM 3.0, Ethernet 10/100/ Mbps Control PC w. advanced CXDI-NE software preinstalled DICOM Storage, Print Management, Modality Worklist, Performed Procedure Steps (MPPS) DICOM 3.0 compliant. X-ray images are sent to servers using Storage Service Class (SCU) and to printers using Print Management Service Class (SCU). C-echo and Storage Commitment – all as SCU. Detector Docking Type AEC 1.8 Canon CXDI-401C Wireless (Portable) 125 microns 3320 x 3408 (11.3 Megapixels) High sensitivity Cesium Iodide (CsI) 41.5 x 42.6 cm Preview image: Approx. 3 seconds High-resolution image: Approx. 5 seconds Approx. 9 seconds DICOM 3.0, Ethernet 10/100/ Mbps Control PC w. advanced CXDI-NE software preinstalled DICOM Storage, Print Management, Modality Worklist, Performed Procedure Steps (MPPS) DICOM 3.0 compliant. X-ray images are sent to servers using Storage Service Class (SCU) and to printers using Print Management Service Class (SCU). C-echo and Storage Commitment – all as SCU. Slim housing with minimised spacing between the detector and the patient in order to optimise image quality. The slim assembly construction around the detector minimises the inactive ‘dead’ area. 5-field, solid state, carbon fibre Anti-scatter Grids Type 14200246 ADORA DRi Technical Specifications v. 4615 Page 7/18 Transparent, stationary with Canon grid line removal algorithm and automatic grid presence detection Construction Legend Display Specification 1.9 Carbon fibre covered and interspaced; easy interchange Colour and symbol coding for easy identification Grid info is displayed in the SmartHandle user interface Select among a range of grids; see options at page 12 - 10:1 110 cm 52 l/cm parallel to long or short edge - 10:1 140 cm 52 l/cm parallel to long or short edge - 12:1 180 cm 52 l/cm parallel to long or short edge User-interface The Adora ‘SmartHandle’ is provided at the X-ray tube control console for easy manually controlled, motorised positioning: enables hands-on, power-assisted positioning in all three dimensions, and is safe in operation by means of the InTouch technology with light indicating active state at the base. It can be activated any time for manual operation, e.g. minor adjustments of pre-set auto-positions. A 12” LCD touch-screen displays the SmartHandle movement modes with self-explanatory icons, positioning data and system messages. The graphics and text on the display auto-rotates to match the tube housing angulation, thus maintaining a natural horizontal viewing orientation (here examples from the identical DRFi). . Preview and generator controls are available on the tube touch screen. A removable control panel is provided on the patient table for table movements and activation of auto-positions (not shown here). An LCD in-room information monitor is provided in a position of individual choice, displaying patient data: name, selected APR, system messages etc. 1.10 Imaging control software Canon’s CXDI Control Software NE provides an optimized workflow which reduces operational steps and supports multiple study acquisitions. The software delivers high-resolution images, generator communication for preset X-ray parameters, as well as actual exposure factors and patient dose information in the DICOM header. Three levels of access can be set for specific user requirements. 14200246 ADORA DRi Technical Specifications v. 4615 Page 8/18 Real-time viewing of high quality images Large and high resolution monitor Optimized workflow with less steps Active GUI for intuitive operation Supports various workflows Suspend exam Emergency study PrePack Protocol Operation Warm and Cool colour settings The Canon CXDI Control Software NE is DICOM 3.0 compliant, HIS/RIS ready, and integrates seamlessly into hospital information systems (PACS). 14200246 ADORA DRi Technical Specifications v. 4615 Page 9/18 2.0 Additional portable detectors In addition to the docked detector, Adora supports up to two portable detectors. Thus, ergonomics and examination flexibility can be further enhanced by adding e.g. a small wired or wireless detector to the configuration. Model Pixel pitch Resolution Scintillator Weight Dimensions Imaging area size Wireless network Battery performance Recharge time Image available time Cycle time Model Pixel pitch Resolution Scintillator Weight Dimensions Imaging area size Wireless network Battery performance Recharge time Image available time Cycle time Canon CXDI-701C Wireless Portable 125 microns 2800 x 3408 pixels (9.5 Megapixels) High sensitivity Cesium Iodide (CsI) 3.3 kg incl. battery 38 x 46 x 1.5 cm 35 x 43 cm IEEE 802.11 n (2.4 GHz) Max mode: 800 images (@ 15-second cycle, 1-second sleep), 3 hours; Ave. mode: 140 images (@ 100second cycle, 1-second sleep), 4 hours; Save mode: 6.5 hours @ sleep mode Approx. 3 hours Preview image: Approx. 3 seconds High-resolution image: Approx. 5 seconds 9 Approx. seconds Canon CXDI-801C Wireless Portable 125 microns 2800 x 2192 pixels (6.1 Megapixels) High sensitivity Cesium Iodide (CsI) 2.3 kg 38 x 31 x 1.5 cm 27.4 x 35 cm IEEE 802.11 n (2.4 GHz) Max mode: 800 images (@ 15-second cycle, 1-second sleep), 3 hours; Ave. mode: 140 images (@ 100second cycle, 1-second sleep), 4 hours; Save mode: 6.5 hours @ sleep mode Less than 3 hours Preview image: 3 seconds High-resolution image: 5 seconds 9 seconds Image #5. The 701C features a smaller pixel size and a higher sensitivity than previous detectors, and enables reduction in radiation doses while maintaining a consistently high imaging quality. The Canon CXDI-801C Wireless is identical with the 701C but smaller in size (27.4 x 35 cm) and available for Adora as an extra, portable, lightweight detector. 14200246 ADORA DRi Technical Specifications v. 4615 Page 10/18 3.0 Options 3.1 Automatic Image Stitching A simple three-step, automatic approach to stitching based on image acquisition from both standing and supine patients. Hardware The stitching panel rotates forward from behind the patient grip stand for image stitching. Both grid and air-gap technique (variable patient-detector distance) can be employed. A patient step is also provided. Image Acquisition Automatic software-controlled acquisition of up to 5 images with automatic motorised tube movements. Ability to adjust the stitch area to reduce radiation exposure. Dedicated stitching push-button for full acquisition sequence with a single button press for a quick and seamless acquisition. 3.2 inOrbit for iso-center Tracking Enables operators to make different exposures of the same anatomy by changing the angle of either the tube or the detector. The technique has been developed to make the tube and detector rotate on an imaginable sphere, and is highly useful in examinations where multiple precision images of the same anatomy are needed. 14200246 ADORA DRi Technical Specifications v. 4615 Page 11/18 4.0 Accessories 4.1 Ceiling hoist system The patient ceiling hoist system is indispensable for handling immobile, elderly and overweight patients. Consisting of an integrated patient ceiling hoist and lifting sling, it enables staff to manoeuvre patients into position with minimum hassle and maximum ease. Please refer to Guldmann product literature. 4.2 Table side hand grips Grips to be fixed freely along both sides of the table for increased patient comfort. 4.3 Paper roll holder Mounted on the patient table when laminated or unlaminated paper is used for hygienic coverage of the table. 4.4 Grids for insertion in detector housing A wide range of colour- and symbol-coded noise reducing grids for insertion in the detector docking unit: - 10:1 110 cm parallel to long or short edge - 10:1 140 cm parallel to long or short edge - 12:1 180 cm parallel to long or short edge 14200246 ADORA DRi Technical Specifications v. 4615 Page 12/18 4.5 Grids for click-on to portable detectors Different grids are offered for fixation directly onto the portable detectors, e.g. - 10:1 110 cm, parallel to long or short edge - 10:1 140 cm, parallel to long or short edge - 10:1 Parallel, parallel to long or short edge - 8:1 110 cm parallel to long edge handle (70C) 4.6 Grid storage cage A wall-mounted storage cage is available in customer specific configurations, depending of the number of grids and the number of additional portable detectors to be stored. 4.7 Mattresses Transfer mattresses in the patient table shape design with both high friction and low friction surfaces. 4.8 Patient table support stand Height-adjustable support stand to be placed under the table in case of emergency CPR to prevent deflection of the patient table. 14200246 ADORA DRi Technical Specifications v. 4615 Page 13/18 4.9 Patient Grip stand For the convenience and support of standing patients, including a height adjustable lateral grip. The Patient Grip stand is also used for stitching examinations (here with inactive stitching positioner). 4.10 Foot switch Enables easier movement of the table up & down and XY table floating. 4.11 Auto-positioning button Wall-mounted pushbutton for convenient access to activation of an auto-position. 4.12 Laser cross In addition to the collimator light, a laser cross can be built into the tube assembly for a more precise identification of the center of the beam 14200246 ADORA DRi Technical Specifications v. 4615 Page 14/18 4.14 Foot step Building-blocks for configurable foot step - can also be configured as a two-step staircase. 4.15 Remote control Wireless, programmable, remote control for onehand operation as supplement to the SmartHandle and Control panel at the patient table. Autumn 2015 introductions 4.15 Foot switch RAD exposure foot switch for control room; alternative to hand held exposure switch. 4.16 Auto-position foot switch Foot switch for activating auto-positions; supplement/alternative to the wall mounted button. 14200246 ADORA DRi Technical Specifications v. 4615 Page 15/18 5.0 Installation 5.1 Installation data Power connection req. 3 x 400V, Phase and Ground, 80A fuse 1 x 230V, Grounded, 16 A fuse Floor space requirement Minimum 3300 x 5000 mm Optimum ceiling height Optimum 3000 mm Minimum 2800 mm Room access requirements Height min. 180 cm Width: min. 116 cm crated; min 105 cm uncrated Complete table weight 360 kg (794 lbs) Ceiling unit weight 740 kg (1630 lbs) Patient grip stand 50 kg (110 lbs) Floor Ground wire in the floor is recommended for better working environment Measurements of the celling unit and the patient table. Further information 14200246 ADORA DRi Technical Specifications v. 4615 Page 16/18 Adora Site Planning Guide (#14200007) Pre-installation Manual (#14200010) 5.2 Operating environment Relative humidity Min. 5% - max. 60% Temperature Min. 10°C - max. 35°C Atmospheric pressure Min. 860 hPa – max. 1060 hPa Audible emission Positioner standby: <45 dB(A) Generator standby: <51 dB(A) Positioner operation: <55 dB(A) Generator operation: <51 dB(A) Mode of operation 40% intermittent operation; 4 min. operation, 6 min. rest Power consumption Location split Control cabinet Exam room Control Area W W W System element split Generator Positioner and image system Total system Total system, 10% intermittent op. W W W W Standby 700 200 200 Operation ≤ 65.000 < 700 200 500 600 1.100 < 65.000 < 1.100 < 1.160* 1.160 * at 6 patients/hour 2 exp./ patient each 100 kV, 200mA, 15 ms Power consumption when turned off Generator <50 W Positioner <25 W Canon PC <1 W Start-up time Less than 120 seconds Shutdown time Depends on the number of exposures per day It is recommended to turn the system off every day after use 5.3 Environment Materials satisfies the RoHS directive, the REACH regulation, and the Montreal protocol 14200246 ADORA DRi Technical Specifications v. 4615 Page 17/18 6.0 Classification and standards Classification UL: Class I, Type B applied part EU/CE: Class IIb (according to annex IX, rule 10) Standards and directives Quality ISO 13485:2012+AC2012 and Canadian MDR CE 93/42/EEC – the Council Directive concerning Medical Devices as transposed into the national legislation of the member states on the market of which we place the product, including all applicable amendments Additional Bek. 664 of 27 June 2005: Håndtering af Affald omkring elektrisk og elektronisk udstyr (in English: WEEE) EU directive 2002/95/EC ROHS – with the exceptions mentioned in annex to the directive concerning X-ray devices Service life 10 years 7.0 Revision History Version Description 1008 First release 4913 Information updated 1314 Minor revisions added 4615 DRi name change; major revision of images; partly text updates DK-8361 Hasselager Denmark T +45 86283500 E [email protected] www.nrtxray.com www.adoraxray.com 14200246 ADORA DRi Technical Specifications v. 4615 Page 18/18
© Copyright 2026 Paperzz