AXIS T90A 2x/3x/4x Installation Guide AXIS T90A 2x

VISTA ZOOM Infra Red Illuminator Instructions
This manual will detail the installation and set up required to get the best
performance from your VISTA Zoom Infra-Red LED illuminator
Contents
1. Back of unit & Wiring Page 2
2. Adjusting the beam angle Page 3
3. Mounting and Set-up Page 4
4. Specifications
Page 5
5. Dimensions Page 6
6. Troubleshooting
Page 7
VISTA Zoom Installation Guide
1
1. Back of Unit
Photocell
Input Cable
12-24V AC/DC
Wiring
Standard Lamp cable - 0.75mm
DC
AC
Black wire
-
~
Red wire
+
~
1.5m
Install in a well
ventilated area
2
Do not continually
stare at lamp
VISTA Zoom Installation Guide
2. Adjusting the beam angle
Alter angle of illumination (Optional)
The angle of illumination can be adjusted using the ‘Zoom Adjustment Screw’
(ZAS) on the front of the illuminator. Using a 4mm hex/allen key, turn the ZAS
clockwise to widen the angle of illumination. Turn the ZAS anti-clockwise to
narrow the angle of illumination. Please refer to the table below to set your
required angle of illumination.
Please note: The default setting for the Zoom illuminator will be 90°
Angle°
(FWHM)
Achievable
Distance (m)*
No. Turns
3.5
100
38
6
75
32
8
55
28
10
45
24
15
30
22
20
22
19
30
20
17
40
18
15
50
17
11
60
16
8
70
15
6
80
14
3
90
11
0
Zoom Adjustment
Screw
Using a 4mm Hex/Allen key
Clockwise = Widens illumination
Counterclockwise = Narrows illumination
*Subject to camera performance
VISTA Zoom Installation Guide
3
3. Mounting and Set-up
1
2
Position illuminator adjacent to camera and
point towards scene (Optional night set-up
for optimum image performance)
Adjust vertical and horizontal
position of lamp to ensure full
field of view illuminated
TARGET
3 Tighten all fixings
4
Connect Illuminator to low voltage power supply: Installers can extend or reduce lead length
using appropriate cable and weather proof box. Power the unit using 12-24V AC/DC
Optional Bracketry
Wall Mount
4
Ptz Mount
Dome Mount
Pole Mount
VISTA Zoom Installation Guide
4. Specifications
VISTA Zoom
Wavelength
850nm Infra-Red
Max Distance
100m*
(see Page 3 for full distances)
Angles available
3.5° to 90°
Consumption
5W max
Input
12-24V AC/DC
Current (DC only)
12V: 0.37A
24V: 0.21A
Environment
IP66
Temp Range
-30° to +50°C
Weight
0.85kg (1.9lbs)
Dimensions
LxWxD
124 x 90 x 176mm
(4.8” x 3.5” x 7”)
Integrated Control Features
• Built-in photocell for automatic on/off operation
VISTA Zoom Installation Guide
5
5.Dimensions
176.1mm
90.6mm
6
123.5mm
93.4mm
Front
Rear
VISTA Zoom Installation Guide
6. Troubleshoot
Ensure all tests are undertaken by a qualified, trained engineer.
Ensure safe working practices are followed at all times.
Step 1: Basics
• Ensure power is 12-24V AC/DC
• Check photocell is working-cover photocell, light should turn on.
• Ensure power supply is suitably rated to product - check page 5 for
specifications
• If longer cables used, ensure sufficient voltage is provided to allow for
voltage drops across the cable
If OK…
Step 2: Lamp Test
• Check current draw of lamp corresponds to specification on page 5
To check lamp current remove +ve (red) lead from external power source and
connect multimeter (set to 10A) in line with the lamp. [One lead of multimeter
in common (COM), other lead into 10A socket of multimeter; set multimeter to
read Amps]. For correct current draw, see page 5.
Step 3: Set-up Camera, lens and illumination
• Check alignment of lamp and angle selected
• Check camera lens – fully open at night & set correctly
• Check performance specification of illuminator with camera and lens to
ensure required distance is achievable
Step 4: Call VISTA for further assistance
Note down:
• Model and serial number of illuminator
• Camera make and model
• Lens make and model
If the Vista lamp is still not delivering the required performance, please contact us for further
assistance:
Vista, 210 Wharfedale Road, Winnersh Triangle, Workingham, Berkshire, UK, RG41 5TP
Tel: +44 (0)118 912 5000
Fax: +44 (0)1 18 912 5001
VISTA Zoom Installation Guide
www.vista-cctv.com
7
Vista, 210 Wharfedale Road, Winnersh Triangle, Workingham, Berkshire RG41 5TP