Biomet Peritrochanteric Nail (PTN) System Brochure

Biomet
Peritrochanteric Nail (PTN) System
Biomet Trauma...Providing Innovative Solutions
For A Variety Of Hip And Femoral Fractures
The Peritrochanteric Nail System provides four lag screw options and
a range of nail lengths—for optimal flexibility of technique. Biomet
Peritrochanteric Nail (PTN) System is indicated for the treatment of
fractures of the femur including: non-comminuted and comminuted
midshaft fracture, subtrochanteric fracture, distal third fracture,
combination fractures of the shaft and neck, intertrochanteric fracture,
and combination intertrochanteric and subtrochanteric fractures.
The Biomet Peritrochanteric Nail (PTN) System is also indicated for
osteotomies, reconstructive procedures following tumor resection,
revision procedures where other treatments or devices have failed, and
arthrodesis. Not for sale in Canada.
One Surgeon. One Patient.
Over 1 million times per year, Biomet helps one surgeon
provide personalized care to one patient.
The science and art of medical care is to provide the right
solution for each individual patient. This requires clinical
mastery, a human connection between the surgeon and
the patient, and the right tools for each situation.
At Biomet, we strive to view our work through the eyes of
one surgeon and one patient. We treat every solution we
provide as if it’s meant for a family member.
Our approach to innovation creates real solutions that assist
each surgeon in the delivery of durable personalized care
to each patient, whether that solution requires a minimally
invasive surgical technique, advanced biomaterials or a
patient-matched implant.
When one surgeon connects with one patient to provide
personalized care, the promise of medicine is fulfilled.
Short and Extra Short Peritrochanteric Nails
• An effective alternative to conventional compression hip
screws, particularly for unstable fractures
• A 6° proximal bend facilitates accurate and easy nail insertion
• Pre-assembled setscrew within the nail facilitates
intra-operative efficiency by eliminating the potential for
loss of setscrew in soft tissue
• Small, 15.9mm proximal outer diameter lessens bone removal and minimizes adverse effects on the abductor function
• Offers a single, elliptical hole distally that will allow either static or dynamic locking
• 128° valgus angle enables optimal anatomic restoration of the femoral neck
Short Nail
15.9mm
Proximal
O.D.
11mm Lag
Screw
Orifice
128°
Valgus
Angle
Length
22cm
Extra Short Nail
6°
Proximal
Bend
11mm
& 13mm
Shaft O.D.
5mm Slot for
Static or
Dynamic Distal
Locking
11mm & 13mm
Shaft O.D.
Length
17cm
Long Peritrochanteric Nails
• A 6° proximal bend facilitates accurate and easy nail insertion
15.9mm
Proximal
O.D.
11mm Lag
Screw
Orifice
128°
Valgus
Angle
6°
Proximal
Bend
11mm
Shaft O.D.
Length
24cm - 48cm
(2cm increments)
1.8m Radius
of Curvature in
the A/P plane
5mm Slot for
Static or
Dynamic Distal
Locking
5mm Slot for
Static Distal
Locking
• Flexibility—either dynamic locking (single screw) or static locking
• Pre-assembled setscrew within the nail facilitates intra operative efficiency by eliminating the potential for loss of
setscrew in soft tissue
• Small, 15.9mm proximal outer diameter lessens bone removal and minimizes adverse effects on the abductor function
• An optimal 1.8m radius of curvature in the A/P plane, with 9°
of anteversion
• 128° valgus angle enables optimal anatomic restoration of the femoral neck
Lag Screws
• A
vailable in multiple options with lengths ranging from 65 to
120mm, in 5mm increments
• A 128° lag screw trajectory meets the optimal anatomic neck angle and reduces extensive inventory requirements
Pre-assembled Setscrew
Forked setscrews are pre-installed in all
Peritrochanteric Nails. Their function is to capture the
lag screw in the nail.
• R
everse buttress threads enable efficient advancement into
the femoral head, but limit advancement of the lag screw
into the acetabulum
• Telescoping lag screws offer an atraumatic soft tissue sleeve
that allows the lag screw to slide under compression due to
fracture collapse, without impinging the lateral soft tissue
• K
eyed telescoping lag screw minimizes femoral head rotation
by limiting lag screw rotation inside the atraumatic soft
tissue sleeve
• S
olid sliding lag screw enables healing by allowing fracture
collapse; flats shaft design allows it to slide
• A
Solid fixed lag screw (based upon specific indication),
yields a single, stable, non-sliding construct – the flats
designed into the shaft hold the lag screw into position
when the setscrew is fully engaged
• The combination of the lip on the lateral aspect of all lag
screws and the pre-assembled setscrew limits the
“Z Effect” from occuring post surgery
Telescoping Keyless Lag Screw
Telescoping Keyed Lag Screw
Solid Sliding Lag Screw
Solid Fixed Lag Screw
Telescoping Lag
Screw yields to
fracture collapse,
without impinging
soft tissue
Peritrochanteric and UniFlex
Antegrade Femoral Nail Instrumentation
• Convenient single tray contains complete instrumentation for both
Peritrochanteric and UniFlex antegrade nailing applications,
creating intraoperative efficiencies
• Color-coded instruments are intuitive and easy
to find and use
• High-clearance radiolucent targeting outrigger is
strong, lightweight and intuitive—meeting clinical
needs while creating intraoperative efficiencies
• One-step reamer allows efficient single-step
reaming of the proximal femur via trochanteric
entry point
• Modular reamers and flexible nitinol shaft
facilitates non-exchange medullary canal reaming
A Single Tray System - Contains
Both Peritrochanteric and UniFlex
Antegrade Femoral Nail Instrumentation
Versatile Radiolucent Targeting Driver
meets clinical need and surgeon
preference for either trochanteric or
pirformis nailing
This material is intended for health care professionals and the Biomet sales
force only. Distribution to any other recipient is prohibited. All content herein is
protected by copyright, trademarks and other intellectual property rights owned
by or licensed to Biomet Inc. or its affiliates unless otherwise indicated. This material
must not be redistributed, duplicated or disclosed, in whole or in part, without the
express written consent of Biomet.
Check for country product clearances and reference product specific instructions
for use. For complete product information, including indications, contraindications,
warnings, precautions, and potential adverse effects, see the package insert and
Biomet’s website.
Not for distribution in France.
Legal Manufacturer
Biomet Trauma
56 East Bell Drive
P.O. Box 587
Warsaw, Indiana 46581
USA
©2014 Biomet Trauma • Form No. BMET0299.0-GBL • REV0714
www.biomet.com
Authorised Representative
Biomet UK Ltd.
Waterton Industrial Estate
Bridgend, South Wales
CF31 3XA
UK