Biomet Peritrochanteric Nail (PTN) System Biomet Trauma...Providing Innovative Solutions For A Variety Of Hip And Femoral Fractures The Peritrochanteric Nail System provides four lag screw options and a range of nail lengths—for optimal flexibility of technique. Biomet Peritrochanteric Nail (PTN) System is indicated for the treatment of fractures of the femur including: non-comminuted and comminuted midshaft fracture, subtrochanteric fracture, distal third fracture, combination fractures of the shaft and neck, intertrochanteric fracture, and combination intertrochanteric and subtrochanteric fractures. The Biomet Peritrochanteric Nail (PTN) System is also indicated for osteotomies, reconstructive procedures following tumor resection, revision procedures where other treatments or devices have failed, and arthrodesis. Not for sale in Canada. One Surgeon. One Patient. Over 1 million times per year, Biomet helps one surgeon provide personalized care to one patient. The science and art of medical care is to provide the right solution for each individual patient. This requires clinical mastery, a human connection between the surgeon and the patient, and the right tools for each situation. At Biomet, we strive to view our work through the eyes of one surgeon and one patient. We treat every solution we provide as if it’s meant for a family member. Our approach to innovation creates real solutions that assist each surgeon in the delivery of durable personalized care to each patient, whether that solution requires a minimally invasive surgical technique, advanced biomaterials or a patient-matched implant. When one surgeon connects with one patient to provide personalized care, the promise of medicine is fulfilled. Short and Extra Short Peritrochanteric Nails • An effective alternative to conventional compression hip screws, particularly for unstable fractures • A 6° proximal bend facilitates accurate and easy nail insertion • Pre-assembled setscrew within the nail facilitates intra-operative efficiency by eliminating the potential for loss of setscrew in soft tissue • Small, 15.9mm proximal outer diameter lessens bone removal and minimizes adverse effects on the abductor function • Offers a single, elliptical hole distally that will allow either static or dynamic locking • 128° valgus angle enables optimal anatomic restoration of the femoral neck Short Nail 15.9mm Proximal O.D. 11mm Lag Screw Orifice 128° Valgus Angle Length 22cm Extra Short Nail 6° Proximal Bend 11mm & 13mm Shaft O.D. 5mm Slot for Static or Dynamic Distal Locking 11mm & 13mm Shaft O.D. Length 17cm Long Peritrochanteric Nails • A 6° proximal bend facilitates accurate and easy nail insertion 15.9mm Proximal O.D. 11mm Lag Screw Orifice 128° Valgus Angle 6° Proximal Bend 11mm Shaft O.D. Length 24cm - 48cm (2cm increments) 1.8m Radius of Curvature in the A/P plane 5mm Slot for Static or Dynamic Distal Locking 5mm Slot for Static Distal Locking • Flexibility—either dynamic locking (single screw) or static locking • Pre-assembled setscrew within the nail facilitates intra operative efficiency by eliminating the potential for loss of setscrew in soft tissue • Small, 15.9mm proximal outer diameter lessens bone removal and minimizes adverse effects on the abductor function • An optimal 1.8m radius of curvature in the A/P plane, with 9° of anteversion • 128° valgus angle enables optimal anatomic restoration of the femoral neck Lag Screws • A vailable in multiple options with lengths ranging from 65 to 120mm, in 5mm increments • A 128° lag screw trajectory meets the optimal anatomic neck angle and reduces extensive inventory requirements Pre-assembled Setscrew Forked setscrews are pre-installed in all Peritrochanteric Nails. Their function is to capture the lag screw in the nail. • R everse buttress threads enable efficient advancement into the femoral head, but limit advancement of the lag screw into the acetabulum • Telescoping lag screws offer an atraumatic soft tissue sleeve that allows the lag screw to slide under compression due to fracture collapse, without impinging the lateral soft tissue • K eyed telescoping lag screw minimizes femoral head rotation by limiting lag screw rotation inside the atraumatic soft tissue sleeve • S olid sliding lag screw enables healing by allowing fracture collapse; flats shaft design allows it to slide • A Solid fixed lag screw (based upon specific indication), yields a single, stable, non-sliding construct – the flats designed into the shaft hold the lag screw into position when the setscrew is fully engaged • The combination of the lip on the lateral aspect of all lag screws and the pre-assembled setscrew limits the “Z Effect” from occuring post surgery Telescoping Keyless Lag Screw Telescoping Keyed Lag Screw Solid Sliding Lag Screw Solid Fixed Lag Screw Telescoping Lag Screw yields to fracture collapse, without impinging soft tissue Peritrochanteric and UniFlex Antegrade Femoral Nail Instrumentation • Convenient single tray contains complete instrumentation for both Peritrochanteric and UniFlex antegrade nailing applications, creating intraoperative efficiencies • Color-coded instruments are intuitive and easy to find and use • High-clearance radiolucent targeting outrigger is strong, lightweight and intuitive—meeting clinical needs while creating intraoperative efficiencies • One-step reamer allows efficient single-step reaming of the proximal femur via trochanteric entry point • Modular reamers and flexible nitinol shaft facilitates non-exchange medullary canal reaming A Single Tray System - Contains Both Peritrochanteric and UniFlex Antegrade Femoral Nail Instrumentation Versatile Radiolucent Targeting Driver meets clinical need and surgeon preference for either trochanteric or pirformis nailing This material is intended for health care professionals and the Biomet sales force only. Distribution to any other recipient is prohibited. All content herein is protected by copyright, trademarks and other intellectual property rights owned by or licensed to Biomet Inc. or its affiliates unless otherwise indicated. This material must not be redistributed, duplicated or disclosed, in whole or in part, without the express written consent of Biomet. Check for country product clearances and reference product specific instructions for use. For complete product information, including indications, contraindications, warnings, precautions, and potential adverse effects, see the package insert and Biomet’s website. Not for distribution in France. Legal Manufacturer Biomet Trauma 56 East Bell Drive P.O. Box 587 Warsaw, Indiana 46581 USA ©2014 Biomet Trauma • Form No. BMET0299.0-GBL • REV0714 www.biomet.com Authorised Representative Biomet UK Ltd. Waterton Industrial Estate Bridgend, South Wales CF31 3XA UK
© Copyright 2026 Paperzz