Planning guide Urban II - ABP

Planning guide Urban II
for glass panel (t: 1/4“ - 1/2“ )
A
min. 23⁄8“
min. 60
fixed glass panel
sliding glass panel
13⁄16“
30
19⁄16“
40
1¼“
32
19⁄16“
40
max. 132 lb
FGH
TH
H
1/4“-1/2“
6 - 12
TH
inside
F=
5/16“
8
DB > 215⁄8“
FGH
9/16“
14
1/4“-1/2“
6 - 12
outside
min.
5/64“
2
track rail length L = A - (24mm) 15/16“
B
Note:
Reduce top track length opposite of pre-drilled holes
3¾“
95
65_30_00.0114_US_Urban2_2016_03jb
The standard track rails can, if necessary, shorten on the door side.
By shortening the track rail, the passage width DB changes.
The door width TB is to reduce the same dimension to be shortened.
The dimension to the fixed glass panel FGB remains unchanged.
A
31⁄8“
80
31⁄8“
*315⁄16“
*100
x
4 1⁄8“
80
TB
© by ABP-Beyerle GmbH - technical amendments reserved - mm acurate; Inch approx
104
*315⁄16“
*100
B
FGB
x
*recommended
A = DLO-W (Day Light Opening - Width)
L = track rail length
TB = sliding glass panel width
TH = sliding glass panel height
FGB = fixed glass panel width
FGH = fixed glass panel height
DB = Clear opening width
H = track rail height
x = gap size min. 5/64“ (2mm)
F = Horizontal gap at bottom
of sliding glass panel
Planning guide Urban II
for glass panel (t: 1/4“ - 1/2“ )
standard length:
L
B
TB
FGB
DB
calculation fixed glass panel heigth (FGH):
48 3⁄16“ 47 ¼“ 16 9⁄16“ 26 3⁄8“ 24 7⁄16“ 21 11⁄16“
TH = H - F - 1 ¼“
FGH = H + 1 9⁄16“- 5⁄64“
TH =
FGH =
60“ 59 1⁄16“ 22 5⁄8“ 32 5⁄16“ 30 ½“ 27 3⁄8“
71 19⁄16“ 70 7⁄8“ 28 9⁄16“ 38 3⁄16“ 36 7⁄16“ 33 5⁄16“
*315⁄16“
*100
31⁄8“
80
31⁄8“
80
13⁄16“
30
B
*315⁄16“
*100
for custom special length only:
calculation glass panel width:
19⁄16“
TB = A/2 + 2 5⁄16“
FGB = A/2 + 1/2“
B = FGB - 7 7⁄8“
DB = A - FGB - 2 3⁄16“ - x
Ø 5/8“
16
19⁄16“
40
ex.
A = 68 3⁄8“
TB = 68 3⁄8“ /2 + 2 5⁄16“ = 36 ½“
FGB = 68 3⁄8“ /2 + 1/2“ = 34 11⁄16“
B = 34 11⁄16 - 7 7⁄8“ = 26 13⁄16“
DB = 68 3⁄8“ - 34 11⁄16“ - 2 3⁄16“ - 5⁄64“ = 31 27⁄64“
Ø 5/8“
16
?
knob/
flush pull/
handle bar
A
calculation door glass panel heigth (TH):
calculation:
max. 132 lb
TH
FGH
A
=
H
=
TB =
FGB =
B
=
DB =
TB
TB = A/2 + 2 5⁄16“
Beyerle US L.L.C.
5126 S Royal Atlanta Dr. , Tucker, GA 30084
Phone (770) 349 - 6324 , Fax (770) 934 - 3384 , mail: [email protected], www.beyerle-us.com
FGB
FGB = A/2 + 1/2“
*recommende
technical changes reserved - version 03.2016 mm acurate; Inch approx
© by ABP-Beyerle GmbH
A = DLO-W (Day Light Opening - Width)
L = track rail length
TB = sliding glass panel width
TH = sliding glass panel height
FGB = fixed glass panel width
FGH = fixed glass panel height
DB = Clear opening width
H = track rail height
x = gap size min. 5/64“ (2mm)
F = Horizontal gap at bottom
of sliding glass panel