Planning guide Urban II for glass panel (t: 1/4“ - 1/2“ ) A min. 23⁄8“ min. 60 fixed glass panel sliding glass panel 13⁄16“ 30 19⁄16“ 40 1¼“ 32 19⁄16“ 40 max. 132 lb FGH TH H 1/4“-1/2“ 6 - 12 TH inside F= 5/16“ 8 DB > 215⁄8“ FGH 9/16“ 14 1/4“-1/2“ 6 - 12 outside min. 5/64“ 2 track rail length L = A - (24mm) 15/16“ B Note: Reduce top track length opposite of pre-drilled holes 3¾“ 95 65_30_00.0114_US_Urban2_2016_03jb The standard track rails can, if necessary, shorten on the door side. By shortening the track rail, the passage width DB changes. The door width TB is to reduce the same dimension to be shortened. The dimension to the fixed glass panel FGB remains unchanged. A 31⁄8“ 80 31⁄8“ *315⁄16“ *100 x 4 1⁄8“ 80 TB © by ABP-Beyerle GmbH - technical amendments reserved - mm acurate; Inch approx 104 *315⁄16“ *100 B FGB x *recommended A = DLO-W (Day Light Opening - Width) L = track rail length TB = sliding glass panel width TH = sliding glass panel height FGB = fixed glass panel width FGH = fixed glass panel height DB = Clear opening width H = track rail height x = gap size min. 5/64“ (2mm) F = Horizontal gap at bottom of sliding glass panel Planning guide Urban II for glass panel (t: 1/4“ - 1/2“ ) standard length: L B TB FGB DB calculation fixed glass panel heigth (FGH): 48 3⁄16“ 47 ¼“ 16 9⁄16“ 26 3⁄8“ 24 7⁄16“ 21 11⁄16“ TH = H - F - 1 ¼“ FGH = H + 1 9⁄16“- 5⁄64“ TH = FGH = 60“ 59 1⁄16“ 22 5⁄8“ 32 5⁄16“ 30 ½“ 27 3⁄8“ 71 19⁄16“ 70 7⁄8“ 28 9⁄16“ 38 3⁄16“ 36 7⁄16“ 33 5⁄16“ *315⁄16“ *100 31⁄8“ 80 31⁄8“ 80 13⁄16“ 30 B *315⁄16“ *100 for custom special length only: calculation glass panel width: 19⁄16“ TB = A/2 + 2 5⁄16“ FGB = A/2 + 1/2“ B = FGB - 7 7⁄8“ DB = A - FGB - 2 3⁄16“ - x Ø 5/8“ 16 19⁄16“ 40 ex. A = 68 3⁄8“ TB = 68 3⁄8“ /2 + 2 5⁄16“ = 36 ½“ FGB = 68 3⁄8“ /2 + 1/2“ = 34 11⁄16“ B = 34 11⁄16 - 7 7⁄8“ = 26 13⁄16“ DB = 68 3⁄8“ - 34 11⁄16“ - 2 3⁄16“ - 5⁄64“ = 31 27⁄64“ Ø 5/8“ 16 ? knob/ flush pull/ handle bar A calculation door glass panel heigth (TH): calculation: max. 132 lb TH FGH A = H = TB = FGB = B = DB = TB TB = A/2 + 2 5⁄16“ Beyerle US L.L.C. 5126 S Royal Atlanta Dr. , Tucker, GA 30084 Phone (770) 349 - 6324 , Fax (770) 934 - 3384 , mail: [email protected], www.beyerle-us.com FGB FGB = A/2 + 1/2“ *recommende technical changes reserved - version 03.2016 mm acurate; Inch approx © by ABP-Beyerle GmbH A = DLO-W (Day Light Opening - Width) L = track rail length TB = sliding glass panel width TH = sliding glass panel height FGB = fixed glass panel width FGH = fixed glass panel height DB = Clear opening width H = track rail height x = gap size min. 5/64“ (2mm) F = Horizontal gap at bottom of sliding glass panel
© Copyright 2026 Paperzz