XX 1.2 GI 12 VX The lens arrays of Fresnel Technologies’ XX 1.2 GI 12 VX series are intended to be used in passive infrared motion detector devices. They are optimized for dual-element pyroelectric detectors. They are normally used with the grooved side facing the pyroelectric detector, and curved at a 1.2 inch (30.5 mm) radius about the sensitive area of the detector (see Figure 1). In this case, the detector and the lens array should be inclined downward at an angle of 12 degrees, for most of the types. The detector position should be 0.810" (20.6 mm) below the upper edge, and centered left-right (see Figure 2). The overall dimensions of the arrays are 1.677" ± 0.010" (42.6 mm ± 0.3 mm) high by 2.402" ± 0.010" (61 mm ± 0.3 mm) wide by 0.015" ± 0.004" (0.38 mm ± 0.1 mm) thick. Border width is approximately 1/8" (3 mm). Centering is held to 0.015" (0.38 mm) in both directions. Fresnel Technologies, Inc. is the premier manufacturer of Fresnel lens arrays. We have led the industry in the development of new lenses and materials to advance the state of the art of passive infrared motion detection. Our lenses and lens arrays have been incorporated into most passive infrared devices using refractive optics since 1976. Our quality standards are the highest in the industry. Surface finish and inclusions are such that no defect is visible at a distance of 3 feet (1 meter) under ordinary light. There are no functional flaws in our products whatsoever. Our POLY IR® infrared-transmitting materials are the best available in stiffness and in transmittance in the 8 to 14 µm region. Active lens segments are made from our acclaimed and patented LODIFF® lens patterns. The LODIFF® lens is covered under U.S. pat. Re. 35,534. Patents have been issued or are pending on each of the designs in the XX 1.2 GI 12 VX series. The members of the series are as follows: WIDE ANGLE ARRAYS WA 1.2 GI 12 V1 WA 1.2 GI 12 V2 WA 1.2 GI 12 V3 WA 1.2 GI 12 V4 WA 1.2 GI 12 V5 DENSE WIDE ANGLE ARRAYS DWA 1.2 GI 12 V1 DWA 1.2 GI 12 V2 LONG RANGE ARRAYS LR 1.2 GI 12 V1 LR 1.2 GI 12 V2 LR 1.2 GI 12 V3 EXTRA WIDE ANGLE ARRAYS EWA 1.2 GI 12 V1 EWA 1.2 GI 12 V2 EWA 1.2 GI 12 V3 ANIMAL ALLEY ARRAYS AA 1.2 GI 12 V1 AA 1.2 GI V1 AA 1.2 GI V2 AA 1.2 GI V3 VERTICAL BARRIER TYPES VB 1.2 GI V1 VB 1.2 GI V2 VB 1.2 GI 12 V1 NEW! PET IMMUNE ARRAY WP 1.2 GI 12 V1 Figures 3-23 illustrate the zone patterns for the arrays. The figures postulate a dual-element detector with 110° coverage both up-down and left-right, amplifier gain of about 5,000, and a mounting height of 3.3 feet (1 meter) for the animal alley lens arrays and 6.8 feet (2.1 meters) for the others, and the 12° tilt for all arrays except the animal alley lens arrays. The AA 1.2 GI 12 V1 is designed to be used at a height of 3.3 feet (1 meter) from the floor, in a unit which retains the 12° downward tilt. The AA 1.2 GI V1 and the AA 1.2 GI V2 are designed to be used at a height of 3.3 feet (1 meter) from the floor, in a unit which is not inclined when mounted at this height but which is inclined downward 12° when mounted at the normal height of 6.8 feet (2.1 meters). The AA 1.2 GI V3 is designed to be used at a height of 3.3 feet (1 meter) from the floor in a unit which is not inclined downward at any mounting height. The VB 1.2 GI V2 is shown in a configuration useful for personnel detection near a door, with the detector mounted so it looks down at the floor. If you wish to use arrays from the XX 1.2 GI 12 VX series at a tilt angle other than 12°, you should move the detector up 0.021" (0.53 mm) for each degree less than 12°, or down by the same amount for each degree greater than 12°. The animal alley lens arrays discussed above are designed to be used at the angles specified, so that this movement is unnecessary. Other configurations (smooth side toward the detector, curved at other radii, tilted at other angles, etc.) can be used as well, but the zone patterns illustrated in Figures 3-21 will not apply. As examples, we offer Figures 24-29, some of which illustrate various XX 1.2 GI 12 VX series arrays curved at a 1.2" radius but not tilted downward 12°, and others of which show them held flat. Other examples are available on request. © Copyright Fresnel Technologies, Inc. 2000-2003 f www.fresneltech.com 030207 TOP VIEW: FRONT VIEW: Lensed Area (seen through lens array in normal use) Detector Envelope 1.2in (30.5mm) Sensitive Area Grooved Surface (in normal use) Border Area FIGURE 1 SIDE VIEW: Detector Envelope 12° Sensitive Area 0.81in (20.6mm) WALL: 1.2in (30.5mm) FIGURE 2 Lens Array WIDE ANGLE ARRAY WA 1.2 GI 12 V1 FRONT VIEW: 20.6mm (0.81in) 42.6mm (1.675in) TOP VIEW: 15m (49ft) 61mm (2.4in) 10m (33ft) 5m (16ft) 88.6° 0 5m (16ft) 10m (33ft) 15m (49ft) SIDE VIEW: 2.1m (6.8ft) 2.5m (8ft) 6m (20ft) 23m (75ft) Figure 3 fresnel technologies inc. 101W. MORNINGSIDE DR. FORT WORTH, TX 76110, U. S. A. (817) 926-7474, FAX:(817)926-7146 1991 WIDE ANGLE ARRAY WA 1.2 GI 12 V2 FRONT VIEW: 20.6mm (0.81in) 42.6mm (1.675in) TOP VIEW: 15m (49ft) 61mm (2.4in) 10m (33ft) 5m (16ft) 94° 0 5m (16ft) 10m (33ft) 15m (49ft) SIDE VIEW: 2.1m (6.8ft) 3m (10ft) 6m (20ft) 23m (75ft) Figure 4 fresnel technologies inc. 101W. MORNINGSIDE DR. FORT WORTH, TX 76110, U. S. A. (817) 926-7474, FAX:(817)926-7146 1991 WIDE ANGLE ARRAY WA 1.2 GI 12 V3 FRONT VIEW: 20.6mm (0.81in) 42.6mm (1.675in) TOP VIEW: 15m (49ft) 61mm (2.4in) 10m (33ft) 5m (16ft) 94° 0 5m (16ft) 10m (33ft) 15m (49ft) SIDE VIEW: 2.1m (6.8ft) 1m 3m (3ft) (10ft) 6m (20ft) 23m (75ft) Figure 5 fresnel technologies inc. 101W. MORNINGSIDE DR. FORT WORTH, TX 76110, U. S. A. (817) 926-7474, FAX:(817)926-7146 1991 WIDE ANGLE ARRAY WA 1.2 GI 12 V4 FRONT VIEW: 20.6mm (0.81in) 42.6mm (1.675in) TOP VIEW: 61mm (2.4in) 10m (33ft) 5m (16ft) 0 88.2° 5m (16ft) 10m (33ft) SIDE VIEW: 2.1m (6.8ft) 1.7m 3.7m (6ft) (12ft) 7m (23ft) 15.6m (51ft) 18m (60ft) Figure 6 fresnel technologies inc. 101W. MORNINGSIDE DR. FORT WORTH, TX 76110, U. S. A. (817) 926-7474, FAX:(817)926-7146 1991 WIDE ANGLE ARRAY WA 1.2 GI 12 V5 FRONT VIEW: 20.6mm (0.81in) 42.6mm (1.675in) TOP VIEW: 15m (49ft) 61mm (2.4in) 10m (33ft) 5m (16ft) 0 90° 5m (16ft) 10m (33ft) 15m (49ft) SIDE VIEW: 2.1m (6.8ft) 2m (7ft) 6m (20ft) 23m (75ft) Figure 7 fresnel technologies inc. 101W. MORNINGSIDE DR. FORT WORTH, TX 76110, U. S. A. (817) 926-7474, FAX:(817)926-7146 1991 WIDE ANGLE ARRAY WP 1.2 GI 12 V1 FRONT VIEW: 20.6mm (0.81in) 42.6mm (1.675in) TOP VIEW: 15m (49ft) 61mm (2.4in) 10m (33ft) 5m (16ft) 88.5° 5m (16ft) 10m (33ft) 15m (49ft) SIDE VIEW: 2.1m (6.8ft) 2m (6.5ft) 4.5m (15ft) fresnel technologies inc. 2002 8.7m (29ft) 17m (55ft) 23m (75ft) Figure 8 101W. MORNINGSIDE DR. FORT WORTH, TX 76110, U. S. A. (817) 926-7474, FAX:(817)926-7146 DENSE WIDE ANGLE ARRAY DWA 1.2 GI 12 V1 FRONT VIEW: 20.6mm (0.81in) TOP VIEW: 42.6mm (1.675in) 7.7m (25ft) 61mm (2.4in) 0 101° 7.7m (25ft) SIDE VIEW: 2.1m (6.8ft) 2.9m (10ft) 5.8m (19ft) 10m (33ft) Figure 9 fresnel technologies inc. 101W. MORNINGSIDE DR. FORT WORTH, TX 76110, U. S. A. (817) 926-7474, FAX:(817)926-7146 1991 DENSE WIDE ANGLE ARRAY DWA 1.2 GI 12 V2 FRONT VIEW: 20.6mm (0.81in) TOP VIEW: 42.6mm (1.675in) 7m (23ft) 61mm (2.4in) 0 101° 7m (23ft) SIDE VIEW: 2.1m (6.8ft) 1m (3ft) 2.9m (10ft) 5.8m (19ft) 9m (30ft) Figure 10 fresnel technologies inc. 101W. MORNINGSIDE DR. FORT WORTH, TX 76110, U. S. A. (817) 926-7474, FAX:(817)926-7146 1991 LONG RANGE ARRAY LR 1.2 GI 12 V1 FRONT VIEW: 20.6mm (0.81in) 42.6mm (1.675in) 61mm (2.4in) TOP VIEW: 84° 2.4m (8ft) 28° 0 11.3° 3m (10ft) 2.4m (8ft) SIDE VIEW: 2.1m (6.8ft) 1m (3ft) 2.3m 2.7m (8ft) (9ft) 30m (98ft) Figure 11 fresnel technologies inc. 101W. MORNINGSIDE DR. FORT WORTH, TX 76110, U. S. A. (817) 926-7474, FAX:(817)926-7146. 1991 LONG RANGE ARRAY LR 1.2 GI 12 V2 FRONT VIEW: 20.6mm (0.81in) 42.6mm (1.675in) 61mm (2.4in) TOP VIEW: 77° 31° 6m (20ft) 3m (10ft) 20° 8.3° 26° CL 0 3m (10ft) 6m (20ft) SIDE VIEW: 2.1m (6.8ft) 1m (3ft) 2.2m (7ft) 3m (10ft) 13.2m (43ft) 23m (75ft) 28m (92ft) Figure 12 fresnel technologies inc. 101W. MORNINGSIDE DR. FORT WORTH, TX 76110, U. S. A. (817) 926-7474, FAX:(817)926-7146 1991 LONG RANGE ARRAY LR 1.2 GI 12 V3 FRONT VIEW: 20.6mm (0.81in) 42.6mm (1.675in) 61mm (2.4in) TOP VIEW: 77° 5m (16ft) 21.5° 14° 2.5m (8ft) 29° 6.5° CL 0 2.5m (8ft) 5.0m (16ft) SIDE VIEW: 2.1m (6.8ft) 1m (3ft) 2.2m (7ft) 3m (10ft) 10.7m (35ft) 18.3m (60ft) 30.5m (100ft) Figure 13 fresnel technologies inc. 101W. MORNINGSIDE DR. FORT WORTH, TX 76110, U. S. A. (817) 926-7474, FAX:(817)926-7146 1991 EXTRA WIDE ANGLE ARRAY EWA 1.2 GI 12 V1 FRONT VIEW: 20.6mm (0.81in) TOP VIEW: 42.6mm (1.675in) 3m (10ft) 61mm (2.4in) 135 0 3m (10ft) SIDE VIEW: 2.1m (6.8ft) 5.6m (18ft) Figure 14 fresnel technologies inc. 101W. MORNINGSIDE DR. FORT WORTH, TX 76110, U. S. A. (817) 926-7474, FAX:(817)926-7146. 1991 EXTRA WIDE ANGLE ARRAY EWA 1.2 GI 12 V2 FRONT VIEW: 20.6mm (0.81in) 42.6 mm (1.675in) TOP VIEW: 61 mm (2.4 in) 19.4° 10m (33ft) 5m (16ft) 0 5m (16ft) 10m (33ft) SIDE VIEW: 2.1m (6.8ft) 1.7m (6ft) 4.6m (15ft) 7.7 m (25ft) 15.3m (50ft) Figure 15 fresnel technologies inc. 101W. MORNINGSIDE DR. FORT WORTH, TX 76110, U. S. A. (817) 926-7474, FAX:(817)926-7146 1991 EXTRA WIDE ANGLE ARRAY EWA 1.2 GI 12 V3 FRONT VIEW: TOP VIEW: 20.6mm (0.81in) 42.6mm (1.675in) 23.5° 61mm (2.4in) 5m (16ft) 0 5m (16ft) SIDE VIEW: 2.1m (6.8ft) 1.2m (4ft) 4.1m (14ft) 8.6m (28ft) 18.7m (62ft) Figure 16 fresnel technologies inc. 101W. MORNINGSIDE DR. FORT WORTH, TX 76110, U. S. A. (817) 926-7474, FAX:(817)926-7146 1991 ANIMAL ALLEY ARRAY AA 1.2 GI 12 V1 FRONT VIEW: 20.6mm (0.81in) TOP VIEW: 42.6mm (1.675in) 9m (30ft) 61mm (2.4in) 100° 0 9m (30ft) SIDE VIEW: 1m (3.3ft) 12m (39ft) Figure 17 fresnel technologies inc. 101W. MORNINGSIDE DR. FORT WORTH, TX 76110, U. S. A. (817) 926-7474, FAX:(817)926-7146 1991 ANIMAL ALLEY ARRAY AA 1.2 GI V1 FRONT VIEW: 42.6mm (1.675in) 20.6mm (0.81in) TOP VIEW: 12° 10m (33ft) 61mm (2.4in) 5m (16ft) 0 5m (16ft) 10m (33ft) 12° SIDE VIEW: 1.0m (3.3ft) 15m (49ft) Figure 18 fresnel technologies inc. 101W. MORNINGSIDE DR. FORT WORTH, TX 76110, U. S. A. (817) 926-7474, FAX:(817)926-7146 1991 ANIMAL ALLEY ARRAY AA 1.2 GI V2 FRONT VIEW: TOP VIEW: 20.6mm (.81in) 42.6mm (1.677in) 10.0 m (32.8 ft) 61mm (2.4in) 5.0 m (16.4 ft) 0 90° 5.0 m (16.4 ft) 10.0 m (32.8 ft) SIDE VIEW: 1.0 m (3.3 ft) 0 15.0 m (49 ft) fresnel technologies inc. 1995 Figure 19 101W. MORNINGSIDE DR. FORT WORTH, TX 76110, U. S. A. (817) 926-7474, FAX:(817)926-7146 ANIMAL ALLEY ARRAY AA 1.2 GI V3 FRONT VIEW: TOP VIEW: 14.4mm (0.567 in) 42.6mm (1.677in) 10.0 m (32.8 ft) 61mm (2.4in) 5.0 m (16.4 ft) 0 90° 5.0 m (16.4 ft) 10.0 m (32.8 ft) SIDE VIEW: 1.0 m (3.3 ft) 0 15.0 m (49 ft) fresnel technologies inc. 1995 Figure 20 101W. MORNINGSIDE DR. FORT WORTH, TX 76110, U. S. A. (817) 926-7474, FAX:(817)926-7146 VERTICAL BARRIER ARRAY VB 1.2 GI V1 FRONT VIEW: inactive areas 20.6mm (0.81in) 42.6mm (1.675in) 61mm (2.4in) TOP VIEW: 0 5.6° SIDE VIEW: 7m (23ft) 2.1m (6.8ft) 18° 44° 15m (49ft) Figure 21 fresnel technologies inc. 101W. MORNINGSIDE DR. FORT WORTH, TX 76110, U. S. A. (817) 926-7474, FAX:(817)926-7146 1991 VERTICAL BARRIER ARRAY VB 1.2 GI V2 FRONT VIEW: 42.6mm (1.675in) 61mm (2.4in) TOP VIEW: 60° Typ. CL CL 60° Typ. CL 5' SIDE VIEW: 2.4m (8ft) 2.5m (8ft) 1m (3ft) 0m 1m (3ft) 2.5m (8ft) Figure 22 fresnel technologies inc. 101W. MORNINGSIDE DR. FORT WORTH, TX 76110, U. S. A. (817) 926-7474, FAX:(817)926-7146 1999 VERTICAL BARRIER ARRAY VB 1.2 GI 12 V1 FRONT VIEW: inactive areas 20.6mm (0.81in) 42.6mm (1.675in) 61mm (2.4in) TOP VIEW: 2.2m (7.2ft) 0 SIDE VIEW: 2.1m (6.8ft) 1.0m (3ft) 2.0m (6ft) 6.0m (19ft) 9.0m (29ft) 10.5m (34ft) 16m (52ft) 22.5m (73ft) AREA COVERED BY CYLINDRICAL LENS Figure 23 fresnel technologies inc. 101W. MORNINGSIDE DR. FORT WORTH, TX 76110, U. S. A. (817) 926-7474, FAX:(817)926-7146. 1991 WIDE ANGLE ARRAY WA 1.2 GI 12 V4 NOT INCLINED DOWNWARD FRONT VIEW: 14.4mm (0.56in) 42.6mm (1.675in) TOP VIEW: 10m (33ft) 61mm (2.4in) 5m (16ft) 88.6° 0 5m (16ft) 10m (33ft) NOTE:this drawing shows the pattern produced by this array when the array is curved at a radius of 1.2 inches (30.5mm) but not inclined downward, and the detector centerline is at a distance of 0.56 inches (14.4mm) below the top edge of the top border. SIDE VIEW: 2.1m (6.9ft) 2m (7ft) 4m (13ft) 7.1m (23ft) 18m (59ft) Figure 24 fresnel technologies inc. 101W. MORNINGSIDE DR. FORT WORTH, TX 76110, U. S. A. (817) 926-7474, FAX:(817)926-7146 1991 EXTRA WIDE ANGLE ARRAY EWA 1.2 GI 12 V3 NOT INCLINED DOWNWARD FRONT VIEW: 14.4mm (0.56in) TOP VIEW: 42.6mm (1.675in) 23.5° 61mm (2.4in) 5m (16.4ft) 0 5m (16.4ft) NOTE:this drawing shows the pattern produced by this array when the array is curved at a radius of 1.2 inches (30.5mm) but not inclined downward, and the detector centerline is at a distance of 0.56 inches (14.4mm) below the top edge of the top border. SIDE VIEW: 2.1m (6.8ft) 1.2m 4.1m (3.9ft) (13.5ft) 8.6m (28.2ft) 18.7m (61ft) Figure 25 fresnel technologies inc. 101W. MORNINGSIDE DR. FORT WORTH, TX 76110, U. S. A. (817) 926-7474, FAX:(817)926-7146 1991 LONG RANGE ARRAY LR 1.2 GI 12 V3 NOT INCLINED DOWNWARD FRONT VIEW: 14.4mm (0.56in) 42.6mm (1.675in) TOP VIEW: 61mm (2.4in) 77° 5m (16ft) 21.5° 14° 2.5m (8ft) 29° 6.56° CL 0 2.5m (8ft) 5m (16ft) NOTE:this drawing shows the pattern produced by this array when the array is curved at a radius of 1.2 inches (30.5mm) but not inclined downward, and the detector centerline is at a distance of 0.56 inches (14.4mm) below the top edge of the top border. SIDE VIEW: 2.1m (6.8ft) 1m (3ft) 2.2m (7ft) 3m (10ft) 10.7m (35ft) 18.3m (60ft) 30.5m (100ft) Figure 26 fresnel technologies inc. 101W. MORNINGSIDE DR. FORT WORTH, TX 76110, U. S. A. (817) 926-7474, FAX:(817)926-7146 1991 LONG RANGE ARRAY LR 1.2 GI 12 V3 MOUNTED FLAT FRONT VIEW: inactive areas 14.4mm (0.56in) 42.6mm (1.675in) 61mm (2.4in) TOP VIEW: 5m (16ft) 14° 2.5m (8ft) 27° 6.6° 21° CL 0 2.5m (8ft) 5m (16ft) NOTE:this drawing shows the pattern produced by this array when the array is held flat at a distance of 1.2 inches (30.5mm) from the detector, but not inclined downward, and the detector centerline is at a distance of 0.56 inches (14.4mm) below the top edge of the top border. SIDE VIEW: 2.1m (6.8ft) 1m (3ft) 2.2m 3m 6m (7ft) (10ft) (20ft) 18.3m (60ft) 30.5m (100ft) Figure 27 fresnel technologies inc. 101W. MORNINGSIDE DR. FORT WORTH, TX 76110, U. S. A. (817) 926-7474, FAX:(817)926-7146 1991 EXTRA WIDE ANGLE ARRAY EWA 1.2 GI 12 V2 MOUNTED FLAT FRONT VIEW: TOP VIEW: 14.4mm (0.56in) 42.6 mm (1.675 in) 59° 53° 61 mm (2.4 in) 46° 8m (26ft) 39.6° 4m (13ft) 0 4m (13ft) 8m (26ft) NOTE:this drawing shows the pattern produced by this array when the array is held flat at a distance of 1.2 inches (30.5mm) from the detector, but not inclined downward, and the detector centerline is at a distance of 0.56 inches (14.4mm) below the top edge of the top border. SIDE VIEW: 2.1m (6.8ft) 1.7m (6ft) 4.6m 6m (15ft) (20ft) 15m (50ft) Figure 28 fresnel technologies inc. 101W. MORNINGSIDE DR. FORT WORTH, TX 76110, U. S. A. (817) 926-7474, FAX:(817)926-7146 1991 ANIMAL ALLEY ARRAY AA 1.2 GI V1 MOUNTED FLAT FRONT VIEW: 42.6mm (1.675in) 20.6mm (0.81in) TOP VIEW: 61mm (2.4in) 8m (26ft) 41° 4m (13ft) 36° 0 4m (13ft) 8m (26ft) SIDE VIEW: NOTE:this drawing shows the pattern produced by this array when the array is held flat at a distance of 1.2 inches (30.5mm) from the detector, but not inclined downward, and the detector centerline is at a distance of 0.81 inches (20.6mm) below the top edge of the top border. 1.0m (3.3ft) 15m (49ft) Figure 29 fresnel technologies inc. 101W. MORNINGSIDE DR. FORT WORTH, TX 76110, U. S. A. (817) 926-7474, FAX:(817)926-7146 1991
© Copyright 2025 Paperzz