XX 1.2 GI 12 VX - Fresnel Technologies

XX 1.2 GI 12 VX
The lens arrays of Fresnel Technologies’ XX 1.2 GI 12 VX series are intended to be used in passive infrared
motion detector devices. They are optimized for dual-element pyroelectric detectors. They are normally used
with the grooved side facing the pyroelectric detector, and curved at a 1.2 inch (30.5 mm) radius about the
sensitive area of the detector (see Figure 1). In this case, the detector and the lens array should be inclined
downward at an angle of 12 degrees, for most of the types. The detector position should be 0.810" (20.6 mm)
below the upper edge, and centered left-right (see Figure 2).
The overall dimensions of the arrays are 1.677" ± 0.010" (42.6 mm ± 0.3 mm) high by 2.402" ± 0.010"
(61 mm ± 0.3 mm) wide by 0.015" ± 0.004" (0.38 mm ± 0.1 mm) thick. Border width is approximately 1/8"
(3 mm). Centering is held to 0.015" (0.38 mm) in both directions.
Fresnel Technologies, Inc. is the premier manufacturer of Fresnel lens arrays. We have led the industry in the
development of new lenses and materials to advance the state of the art of passive infrared motion detection.
Our lenses and lens arrays have been incorporated into most passive infrared devices using refractive optics
since 1976. Our quality standards are the highest in the industry. Surface finish and inclusions are such that
no defect is visible at a distance of 3 feet (1 meter) under ordinary light. There are no functional flaws in our
products whatsoever. Our POLY IR® infrared-transmitting materials are the best available in stiffness and in
transmittance in the 8 to 14 µm region. Active lens segments are made from our acclaimed and patented
LODIFF® lens patterns. The LODIFF® lens is covered under U.S. pat. Re. 35,534. Patents have been issued or
are pending on each of the designs in the XX 1.2 GI 12 VX series.
The members of the series are as follows:
WIDE ANGLE ARRAYS
WA 1.2 GI 12 V1
WA 1.2 GI 12 V2
WA 1.2 GI 12 V3
WA 1.2 GI 12 V4
WA 1.2 GI 12 V5
DENSE WIDE ANGLE ARRAYS
DWA 1.2 GI 12 V1
DWA 1.2 GI 12 V2
LONG RANGE ARRAYS
LR 1.2 GI 12 V1
LR 1.2 GI 12 V2
LR 1.2 GI 12 V3
EXTRA WIDE ANGLE ARRAYS
EWA 1.2 GI 12 V1
EWA 1.2 GI 12 V2
EWA 1.2 GI 12 V3
ANIMAL ALLEY ARRAYS
AA 1.2 GI 12 V1
AA 1.2 GI V1
AA 1.2 GI V2
AA 1.2 GI V3
VERTICAL BARRIER TYPES
VB 1.2 GI V1
VB 1.2 GI V2
VB 1.2 GI 12 V1
NEW! PET IMMUNE ARRAY WP 1.2 GI 12 V1
Figures 3-23 illustrate the zone patterns for the arrays. The figures postulate a dual-element detector with
110° coverage both up-down and left-right, amplifier gain of about 5,000, and a mounting height of 3.3 feet
(1 meter) for the animal alley lens arrays and 6.8 feet (2.1 meters) for the others, and the 12° tilt for all arrays
except the animal alley lens arrays. The AA 1.2 GI 12 V1 is designed to be used at a height of 3.3 feet (1
meter) from the floor, in a unit which retains the 12° downward tilt. The AA 1.2 GI V1 and the AA 1.2 GI V2
are designed to be used at a height of 3.3 feet (1 meter) from the floor, in a unit which is not inclined when
mounted at this height but which is inclined downward 12° when mounted at the normal height of 6.8 feet
(2.1 meters). The AA 1.2 GI V3 is designed to be used at a height of 3.3 feet (1 meter) from the floor in a unit
which is not inclined downward at any mounting height. The VB 1.2 GI V2 is shown in a configuration useful
for personnel detection near a door, with the detector mounted so it looks down at the floor.
If you wish to use arrays from the XX 1.2 GI 12 VX series at a tilt angle other than 12°, you should move the
detector up 0.021" (0.53 mm) for each degree less than 12°, or down by the same amount for each degree
greater than 12°. The animal alley lens arrays discussed above are designed to be used at the angles specified,
so that this movement is unnecessary.
Other configurations (smooth side toward the detector, curved at other radii, tilted at other angles, etc.) can
be used as well, but the zone patterns illustrated in Figures 3-21 will not apply. As examples, we offer Figures
24-29, some of which illustrate various XX 1.2 GI 12 VX series arrays curved at a 1.2" radius but not tilted
downward 12°, and others of which show them held flat. Other examples are available on request.
© Copyright Fresnel Technologies, Inc. 2000-2003
f
www.fresneltech.com
030207
TOP VIEW:
FRONT VIEW:
Lensed Area
(seen through lens array in normal use)
Detector Envelope
1.2in
(30.5mm)
Sensitive Area
Grooved Surface
(in normal use)
Border Area
FIGURE 1
SIDE VIEW:
Detector Envelope
12°
Sensitive Area
0.81in
(20.6mm)
WALL:
1.2in
(30.5mm)
FIGURE 2
Lens Array
WIDE ANGLE ARRAY
WA 1.2 GI 12 V1
FRONT VIEW:
20.6mm
(0.81in)
42.6mm
(1.675in)
TOP VIEW:
15m
(49ft)
61mm
(2.4in)
10m
(33ft)
5m
(16ft)
88.6°
0
5m
(16ft)
10m
(33ft)
15m
(49ft)
SIDE VIEW:
2.1m
(6.8ft)
2.5m
(8ft)
6m
(20ft)
23m
(75ft)
Figure 3
fresnel technologies inc. 101W. MORNINGSIDE DR. FORT WORTH, TX 76110, U. S. A. (817) 926-7474, FAX:(817)926-7146
1991
WIDE ANGLE ARRAY
WA 1.2 GI 12 V2
FRONT VIEW:
20.6mm
(0.81in)
42.6mm
(1.675in)
TOP VIEW:
15m
(49ft)
61mm
(2.4in)
10m
(33ft)
5m
(16ft)
94°
0
5m
(16ft)
10m
(33ft)
15m
(49ft)
SIDE VIEW:
2.1m
(6.8ft)
3m
(10ft)
6m
(20ft)
23m
(75ft)
Figure 4
fresnel technologies inc. 101W. MORNINGSIDE DR. FORT WORTH, TX 76110, U. S. A. (817) 926-7474, FAX:(817)926-7146
1991
WIDE ANGLE ARRAY
WA 1.2 GI 12 V3
FRONT VIEW:
20.6mm
(0.81in)
42.6mm
(1.675in)
TOP VIEW:
15m
(49ft)
61mm
(2.4in)
10m
(33ft)
5m
(16ft)
94°
0
5m
(16ft)
10m
(33ft)
15m
(49ft)
SIDE VIEW:
2.1m
(6.8ft)
1m 3m
(3ft) (10ft)
6m
(20ft)
23m
(75ft)
Figure 5
fresnel technologies inc. 101W. MORNINGSIDE DR. FORT WORTH, TX 76110, U. S. A. (817) 926-7474, FAX:(817)926-7146
1991
WIDE ANGLE ARRAY
WA 1.2 GI 12 V4
FRONT VIEW:
20.6mm
(0.81in)
42.6mm
(1.675in)
TOP VIEW:
61mm
(2.4in)
10m
(33ft)
5m
(16ft)
0
88.2°
5m
(16ft)
10m
(33ft)
SIDE VIEW:
2.1m
(6.8ft)
1.7m 3.7m
(6ft) (12ft)
7m
(23ft)
15.6m
(51ft)
18m
(60ft)
Figure 6
fresnel technologies inc. 101W. MORNINGSIDE DR. FORT WORTH, TX 76110, U. S. A. (817) 926-7474, FAX:(817)926-7146
1991
WIDE ANGLE ARRAY
WA 1.2 GI 12 V5
FRONT VIEW:
20.6mm
(0.81in)
42.6mm
(1.675in)
TOP VIEW:
15m
(49ft)
61mm
(2.4in)
10m
(33ft)
5m
(16ft)
0
90°
5m
(16ft)
10m
(33ft)
15m
(49ft)
SIDE VIEW:
2.1m
(6.8ft)
2m
(7ft)
6m
(20ft)
23m
(75ft)
Figure 7
fresnel technologies inc. 101W. MORNINGSIDE DR. FORT WORTH, TX 76110, U. S. A. (817) 926-7474, FAX:(817)926-7146
1991
WIDE ANGLE ARRAY
WP 1.2 GI 12 V1
FRONT VIEW:
20.6mm
(0.81in)
42.6mm
(1.675in)
TOP VIEW:
15m
(49ft)
61mm
(2.4in)
10m
(33ft)
5m
(16ft)
88.5°
5m
(16ft)
10m
(33ft)
15m
(49ft)
SIDE VIEW:
2.1m
(6.8ft)
2m
(6.5ft)
4.5m
(15ft)
fresnel technologies inc.
2002
8.7m
(29ft)
17m
(55ft)
23m
(75ft)
Figure 8
101W. MORNINGSIDE DR. FORT WORTH, TX 76110, U. S. A. (817) 926-7474, FAX:(817)926-7146
DENSE WIDE ANGLE ARRAY
DWA 1.2 GI 12 V1
FRONT VIEW:
20.6mm
(0.81in)
TOP VIEW:
42.6mm
(1.675in)
7.7m
(25ft)
61mm
(2.4in)
0
101°
7.7m
(25ft)
SIDE VIEW:
2.1m
(6.8ft)
2.9m
(10ft)
5.8m
(19ft)
10m
(33ft)
Figure 9
fresnel technologies inc. 101W. MORNINGSIDE DR. FORT WORTH, TX 76110, U. S. A. (817) 926-7474, FAX:(817)926-7146
1991
DENSE WIDE ANGLE ARRAY
DWA 1.2 GI 12 V2
FRONT VIEW:
20.6mm
(0.81in)
TOP VIEW:
42.6mm
(1.675in)
7m
(23ft)
61mm
(2.4in)
0
101°
7m
(23ft)
SIDE VIEW:
2.1m
(6.8ft)
1m
(3ft)
2.9m
(10ft)
5.8m
(19ft)
9m
(30ft)
Figure 10
fresnel technologies inc. 101W. MORNINGSIDE DR. FORT WORTH, TX 76110, U. S. A. (817) 926-7474, FAX:(817)926-7146
1991
LONG RANGE ARRAY
LR 1.2 GI 12 V1
FRONT VIEW:
20.6mm
(0.81in)
42.6mm
(1.675in)
61mm
(2.4in)
TOP VIEW:
84°
2.4m
(8ft)
28°
0
11.3°
3m
(10ft)
2.4m
(8ft)
SIDE VIEW:
2.1m
(6.8ft)
1m
(3ft)
2.3m 2.7m
(8ft) (9ft)
30m
(98ft)
Figure 11
fresnel technologies inc. 101W. MORNINGSIDE DR. FORT WORTH, TX 76110, U. S. A. (817) 926-7474, FAX:(817)926-7146.
1991
LONG RANGE ARRAY
LR 1.2 GI 12 V2
FRONT VIEW:
20.6mm
(0.81in)
42.6mm
(1.675in)
61mm
(2.4in)
TOP VIEW:
77°
31°
6m
(20ft)
3m
(10ft)
20°
8.3°
26°
CL
0
3m
(10ft)
6m
(20ft)
SIDE VIEW:
2.1m
(6.8ft)
1m
(3ft)
2.2m
(7ft)
3m
(10ft)
13.2m
(43ft)
23m
(75ft)
28m
(92ft)
Figure 12
fresnel technologies inc. 101W. MORNINGSIDE DR. FORT WORTH, TX 76110, U. S. A. (817) 926-7474, FAX:(817)926-7146
1991
LONG RANGE ARRAY
LR 1.2 GI 12 V3
FRONT VIEW:
20.6mm
(0.81in)
42.6mm
(1.675in)
61mm
(2.4in)
TOP VIEW:
77°
5m
(16ft)
21.5°
14°
2.5m
(8ft)
29°
6.5°
CL
0
2.5m
(8ft)
5.0m
(16ft)
SIDE VIEW:
2.1m
(6.8ft)
1m
(3ft)
2.2m
(7ft)
3m
(10ft)
10.7m
(35ft)
18.3m
(60ft)
30.5m
(100ft)
Figure 13
fresnel technologies inc. 101W. MORNINGSIDE DR. FORT WORTH, TX 76110, U. S. A. (817) 926-7474, FAX:(817)926-7146
1991
EXTRA WIDE ANGLE ARRAY
EWA 1.2 GI 12 V1
FRONT VIEW:
20.6mm
(0.81in)
TOP VIEW:
42.6mm
(1.675in)
3m
(10ft)
61mm
(2.4in)
135
0
3m
(10ft)
SIDE VIEW:
2.1m
(6.8ft)
5.6m
(18ft)
Figure 14
fresnel technologies inc. 101W. MORNINGSIDE DR. FORT WORTH, TX 76110, U. S. A. (817) 926-7474, FAX:(817)926-7146.
1991
EXTRA WIDE ANGLE ARRAY
EWA 1.2 GI 12 V2
FRONT VIEW:
20.6mm
(0.81in)
42.6 mm
(1.675in)
TOP VIEW:
61 mm
(2.4 in)
19.4°
10m
(33ft)
5m
(16ft)
0
5m
(16ft)
10m
(33ft)
SIDE VIEW:
2.1m
(6.8ft)
1.7m
(6ft)
4.6m
(15ft)
7.7 m
(25ft)
15.3m
(50ft)
Figure 15
fresnel technologies inc. 101W. MORNINGSIDE DR. FORT WORTH, TX 76110, U. S. A. (817) 926-7474, FAX:(817)926-7146
1991
EXTRA WIDE ANGLE ARRAY
EWA 1.2 GI 12 V3
FRONT VIEW:
TOP VIEW:
20.6mm
(0.81in)
42.6mm
(1.675in)
23.5°
61mm
(2.4in)
5m
(16ft)
0
5m
(16ft)
SIDE VIEW:
2.1m
(6.8ft)
1.2m
(4ft)
4.1m
(14ft)
8.6m
(28ft)
18.7m
(62ft)
Figure 16
fresnel technologies inc. 101W. MORNINGSIDE DR. FORT WORTH, TX 76110, U. S. A. (817) 926-7474, FAX:(817)926-7146
1991
ANIMAL ALLEY ARRAY
AA 1.2 GI 12 V1
FRONT VIEW:
20.6mm
(0.81in)
TOP VIEW:
42.6mm
(1.675in)
9m
(30ft)
61mm
(2.4in)
100°
0
9m
(30ft)
SIDE VIEW:
1m
(3.3ft)
12m
(39ft)
Figure 17
fresnel technologies inc. 101W. MORNINGSIDE DR. FORT WORTH, TX 76110, U. S. A. (817) 926-7474, FAX:(817)926-7146
1991
ANIMAL ALLEY ARRAY
AA 1.2 GI V1
FRONT VIEW:
42.6mm
(1.675in)
20.6mm
(0.81in)
TOP VIEW:
12°
10m
(33ft)
61mm
(2.4in)
5m
(16ft)
0
5m
(16ft)
10m
(33ft)
12°
SIDE VIEW:
1.0m
(3.3ft)
15m
(49ft)
Figure 18
fresnel technologies inc. 101W. MORNINGSIDE DR. FORT WORTH, TX 76110, U. S. A. (817) 926-7474, FAX:(817)926-7146
1991
ANIMAL ALLEY ARRAY
AA 1.2 GI V2
FRONT VIEW:
TOP VIEW:
20.6mm
(.81in)
42.6mm
(1.677in)
10.0 m
(32.8 ft)
61mm
(2.4in)
5.0 m
(16.4 ft)
0
90°
5.0 m
(16.4 ft)
10.0 m
(32.8 ft)
SIDE VIEW:
1.0 m
(3.3 ft)
0
15.0 m
(49 ft)
fresnel technologies inc.
1995
Figure 19
101W. MORNINGSIDE DR. FORT WORTH, TX 76110, U. S. A. (817) 926-7474, FAX:(817)926-7146
ANIMAL ALLEY ARRAY
AA 1.2 GI V3
FRONT VIEW:
TOP VIEW:
14.4mm
(0.567 in)
42.6mm
(1.677in)
10.0 m
(32.8 ft)
61mm
(2.4in)
5.0 m
(16.4 ft)
0
90°
5.0 m
(16.4 ft)
10.0 m
(32.8 ft)
SIDE VIEW:
1.0 m
(3.3 ft)
0
15.0 m
(49 ft)
fresnel technologies inc.
1995
Figure 20
101W. MORNINGSIDE DR. FORT WORTH, TX 76110, U. S. A. (817) 926-7474, FAX:(817)926-7146
VERTICAL BARRIER ARRAY
VB 1.2 GI V1
FRONT VIEW:
inactive areas
20.6mm
(0.81in)
42.6mm
(1.675in)
61mm
(2.4in)
TOP VIEW:
0
5.6°
SIDE VIEW:
7m
(23ft)
2.1m
(6.8ft)
18°
44°
15m
(49ft)
Figure 21
fresnel technologies inc. 101W. MORNINGSIDE DR. FORT WORTH, TX 76110, U. S. A. (817) 926-7474, FAX:(817)926-7146
1991
VERTICAL BARRIER ARRAY
VB 1.2 GI V2
FRONT VIEW:
42.6mm
(1.675in)
61mm
(2.4in)
TOP VIEW:
60° Typ.
CL
CL
60° Typ.
CL
5'
SIDE VIEW:
2.4m
(8ft)
2.5m
(8ft)
1m
(3ft)
0m
1m
(3ft)
2.5m
(8ft)
Figure 22
fresnel technologies inc.
101W. MORNINGSIDE DR. FORT WORTH, TX 76110, U. S. A. (817) 926-7474, FAX:(817)926-7146
1999
VERTICAL BARRIER ARRAY
VB 1.2 GI 12 V1
FRONT VIEW:
inactive areas
20.6mm
(0.81in)
42.6mm
(1.675in)
61mm
(2.4in)
TOP VIEW:
2.2m
(7.2ft)
0
SIDE VIEW:
2.1m
(6.8ft)
1.0m
(3ft)
2.0m
(6ft)
6.0m
(19ft)
9.0m
(29ft)
10.5m
(34ft)
16m
(52ft)
22.5m
(73ft)
AREA COVERED BY CYLINDRICAL LENS
Figure 23
fresnel technologies inc. 101W. MORNINGSIDE DR. FORT WORTH, TX 76110, U. S. A. (817) 926-7474, FAX:(817)926-7146.
1991
WIDE ANGLE ARRAY
WA 1.2 GI 12 V4
NOT INCLINED DOWNWARD
FRONT VIEW:
14.4mm
(0.56in)
42.6mm
(1.675in)
TOP VIEW:
10m
(33ft)
61mm
(2.4in)
5m
(16ft)
88.6°
0
5m
(16ft)
10m
(33ft)
NOTE:this drawing shows the pattern
produced by this array when the array
is curved at a radius of 1.2 inches
(30.5mm) but not inclined downward,
and the detector centerline is at a
distance of 0.56 inches (14.4mm)
below the top edge of the top border.
SIDE VIEW:
2.1m
(6.9ft)
2m
(7ft)
4m
(13ft)
7.1m
(23ft)
18m
(59ft)
Figure 24
fresnel technologies inc. 101W. MORNINGSIDE DR. FORT WORTH, TX 76110, U. S. A. (817) 926-7474, FAX:(817)926-7146
1991
EXTRA WIDE ANGLE ARRAY
EWA 1.2 GI 12 V3
NOT INCLINED DOWNWARD
FRONT VIEW:
14.4mm
(0.56in)
TOP VIEW:
42.6mm
(1.675in)
23.5°
61mm
(2.4in)
5m
(16.4ft)
0
5m
(16.4ft)
NOTE:this drawing shows the pattern
produced by this array when the array
is curved at a radius of 1.2 inches
(30.5mm) but not inclined downward,
and the detector centerline is at a
distance of 0.56 inches (14.4mm)
below the top edge of the top border.
SIDE VIEW:
2.1m
(6.8ft)
1.2m
4.1m
(3.9ft) (13.5ft)
8.6m
(28.2ft)
18.7m
(61ft)
Figure 25
fresnel technologies inc. 101W. MORNINGSIDE DR. FORT WORTH, TX 76110, U. S. A. (817) 926-7474, FAX:(817)926-7146
1991
LONG RANGE ARRAY
LR 1.2 GI 12 V3
NOT INCLINED DOWNWARD
FRONT VIEW:
14.4mm
(0.56in)
42.6mm
(1.675in)
TOP VIEW:
61mm
(2.4in)
77°
5m
(16ft)
21.5°
14°
2.5m
(8ft)
29°
6.56°
CL
0
2.5m
(8ft)
5m
(16ft)
NOTE:this drawing shows the pattern
produced by this array when the array
is curved at a radius of 1.2 inches
(30.5mm) but not inclined downward,
and the detector centerline is at a
distance of 0.56 inches (14.4mm)
below the top edge of the top border.
SIDE VIEW:
2.1m
(6.8ft)
1m
(3ft)
2.2m
(7ft)
3m
(10ft)
10.7m
(35ft)
18.3m
(60ft)
30.5m
(100ft)
Figure 26
fresnel technologies inc. 101W. MORNINGSIDE DR. FORT WORTH, TX 76110, U. S. A. (817) 926-7474, FAX:(817)926-7146
1991
LONG RANGE ARRAY
LR 1.2 GI 12 V3
MOUNTED FLAT
FRONT VIEW:
inactive areas
14.4mm
(0.56in)
42.6mm
(1.675in)
61mm
(2.4in)
TOP VIEW:
5m
(16ft)
14°
2.5m
(8ft)
27°
6.6°
21°
CL
0
2.5m
(8ft)
5m
(16ft)
NOTE:this drawing shows the pattern
produced by this array when the array
is held flat at a distance of 1.2
inches (30.5mm) from the detector,
but not inclined downward, and the
detector centerline is at a distance
of 0.56 inches (14.4mm) below the top
edge of the top border.
SIDE VIEW:
2.1m
(6.8ft)
1m
(3ft)
2.2m 3m
6m
(7ft) (10ft) (20ft)
18.3m
(60ft)
30.5m
(100ft)
Figure 27
fresnel technologies inc. 101W. MORNINGSIDE DR. FORT WORTH, TX 76110, U. S. A. (817) 926-7474, FAX:(817)926-7146
1991
EXTRA WIDE ANGLE ARRAY
EWA 1.2 GI 12 V2
MOUNTED FLAT
FRONT VIEW:
TOP VIEW:
14.4mm
(0.56in)
42.6 mm
(1.675 in)
59°
53°
61 mm
(2.4 in)
46°
8m
(26ft)
39.6°
4m
(13ft)
0
4m
(13ft)
8m
(26ft)
NOTE:this drawing shows the pattern
produced by this array when the array
is held flat at a distance of 1.2
inches (30.5mm) from the detector,
but not inclined downward, and the
detector centerline is at a distance
of 0.56 inches (14.4mm) below the top
edge of the top border.
SIDE VIEW:
2.1m
(6.8ft)
1.7m
(6ft)
4.6m 6m
(15ft) (20ft)
15m
(50ft)
Figure 28
fresnel technologies inc. 101W. MORNINGSIDE DR. FORT WORTH, TX 76110, U. S. A. (817) 926-7474, FAX:(817)926-7146
1991
ANIMAL ALLEY ARRAY
AA 1.2 GI V1
MOUNTED FLAT
FRONT VIEW:
42.6mm
(1.675in)
20.6mm
(0.81in)
TOP VIEW:
61mm
(2.4in)
8m
(26ft)
41°
4m
(13ft)
36°
0
4m
(13ft)
8m
(26ft)
SIDE VIEW:
NOTE:this drawing shows the pattern
produced by this array when the array
is held flat at a distance of 1.2
inches (30.5mm) from the detector,
but not inclined downward, and the
detector centerline is at a distance
of 0.81 inches (20.6mm) below the top
edge of the top border.
1.0m
(3.3ft)
15m
(49ft)
Figure 29
fresnel technologies inc. 101W. MORNINGSIDE DR. FORT WORTH, TX 76110, U. S. A. (817) 926-7474, FAX:(817)926-7146
1991