Lynx Touch with Z-Wave Thermostat Temperature Threshold

Step-By-Step
Lynx Touch with Z-Wave Thermostat Temperature
Threshold Monitoring
The Lynx Touch panels with the Honeywell Z-Wave Thermostat can be set up to monitor the
temperature to alert the user if the room temp goes above or below a desired setting via the
following notification methods:
•
•
Local Sounder
Central Station report
•
•
Follow Me Report
Total Connect 2.0
Steps:
1.
‘Include’ the Z-Wave Thermostats in the automation section of panel according to Lynx
Touch Automation manual.
2. The Threshold Monitoring zones are located on zones 180-185 for the L5200. (Also add
zones 186 and 187 for the L7000). Program the respective zones for each Z-Wave
thermostat in zone programming.
a. Z-Wave Thermostat 1 program zone 180 for high temp monitoring and zone 181 for
low temp monitoring.
b. Z-Wave Thermostat 2 program zone 182 for high temp monitoring and zone 183 for
low temp monitoring.
c. Z-Wave Thermostat 3 program zone 184 for high temp monitoring and zone 185 for
low temp monitoring.
d. Z-Wave Thermostat 4 program zone 186 for high temp monitoring and zone 187 for
low temp monitoring. (L7000 ONLY)
Lynx Touch Temperature Zone Types and options for response
Zone Type
24 hr aux
Monitor
Resident
Monitor
Resident
Response
General
monitor
General
Response
Follow Me Report
Yes
Yes
No
Report to C.S.
Yes
Yes
No
Local Annunciation
Yes- alarm
No – Display only
Yes - auto clears
TotalConnect2.0
Yes
Yes
No
No
No
No
No
No
Yes - tap cancel &
code to clear
Yes- Fault on zone
Yes - Trouble
Notification
No
Yes - Fault
notification
Yes - Fault notification Yes - Fault
notification
-1-
Updated: 1/12/16
Step-By-Step
Setting Up Threshold Monitoring Through the Panel
1. Select “Automation”
4. Select “Threshold Monitor”
2. Select “Thermostats”
5. Select the High or Low Threshold to
see the next selection options
3. Select the desired Thermostat
6. Select the threshold Limit for High or
Low
-2-
Updated: 1/12/16
Step-By-Step
Incorporation with Total Connect 2.0
First, make sure the Lynx Touch has been synced with Total Connect 2.0 and you are able to
view the thermostat in the Automation Window.
1. Select the Scheduling Icon
2. If Threshold Monitoring has not been programmed in the Lynx Touch after panel sync has
been completed, the Threshold Monitoring Hi and Low will not be displayed.
3. Drag the High and Low Thresholds to the desired Temperature and press “Save”
4. Finally, you must sync the data to the panel before these setting will take effect. To do this
you select “Location” then “Sync Panel Data”
-3-
Updated: 1/12/16
Step-By-Step
Setting Up Email/Text Notifications for Monitoring Temperature
Thresholds
1. Select “Setup” in Events, Rules, & Notifications window
2. Select the Automation Icon
3. Select “Thermostat”
-4-
Updated: 1/12/16
Step-By-Step
4. Select “Threshold Alert”
5. Select Desired Thermostat
6.
After Selecting the desired thermostat, Setup your Notification settings and press Save
-5-
Updated: 1/12/16
Step-By-Step
7. Screen shots of threshold monitoring notification messages
-6-
Updated: 1/12/16