Air distribution systems Circular Opticlean OC-R-.… DS 4174 E 04.2013 Circular Opticlean Preliminary remark Flexible duct connection 9 The Circular Opticlean complements KRANTZ KOMPONENTEN’s following advantages: high level of thermal comfort, very little dirt øD 1 5 R HE power level. 2 6 Construction design The Circular Opticlean is designed for mounting in suspended ceil- H3 4 ø A 4) K H accumulation on the ceiling, low pressure drop and low sound H1 range of ceiling air outlets for diffuse air distribution and offers the øE ing systems, especially gypsum board ceilings. The circular face- 3 plate 4 has round staggered perforations whose diameter is 3 mm and pitch 6 mm. The Circular Opticlean is connected to the duct system via a flexible duct 9 or a connection box 8. It is fixed to the ceiling tile using fixing clips 2. Mode of operation n· 2 The supply air is discharged very uniformly through the perforated faceplate and spreads radially in the horizontal plane. As it induces indoor air, the air flow velocity and the difference in temperature Connection box L between the supply and indoor air decrease rapidly; this results in low indoor air velocities and uniform indoor air temperatures. The induced indoor air does not come into contact with the perfor- 8 ø D5 ated faceplate because a layer builds up under the air outlet and acts as an air cushion. This considerably reduces the dirt accu- H2 mulation on the ceiling which usually occurs with turbulent-flow air outlets. K Many suspended ceiling systems incorporate lighting fixtures or let fits perfectly in the overall ceiling design. H3 loudspeakers which look like the Circular Opticlean, so this air outø A 4) øE B 10.2011 Applications p. 2 –– For ceiling heights from 2.5 to 4.5 m –– Maximum temperature difference ±10 K 1) –– Also usable as return air inlet 2) Key 3 Fastener for faceplate 6 Stop buffer 1 Air distribution element 4 Perforated faceplate 8 Connection box 2 Fixing clip 9 Flexible duct 5 Clamping screw Size 1) 2) When used as return air inlet, it may get dirty but is easy to clean 3) Other ceiling thicknesses on request 4) Ceiling cutout 5) The overall height is based on a minimum bending radius of R/D = 0.5. Smaller radii are possible depending on the type of flexible duct used. 2 ø D ø A 4) øE H H1 5) HE l/s m3/h mm mm mm mm mm mm 300 25 – 70 90 – 250 124 300 365 65.5 30.0 250 500 70 – 170 250 – 610 199 490 565 88.2 28.5 385 Size H2 mm H3 mm K 3) mm n·a mm L mm B mm ø D5 mm Weight kg 300 220 3.5 10 – 25 3 · 120° 190 205 124 1.04 500 320 8.0 10 – 25 4 · 90° 265 280 199 2.65 When heating, +10 K with ceiling height up to 3 m, +5 K with ceiling height up to 4.5 m Volume flow rate range www.krantz.de DS 4174 E –– Volume flow rate range from 25 to 170 l/s [90 to 610 m3/h] Circular Opticlean 1) 40 The outlet layout must comply with the maximum allowable indoor air velocities u in the occupied zone in the cooling mode. The indoor air velocity depends on the cooling load that is to be removed from the room. The maximum specific cooling capacity q· depends on the discharge height and the maximum allowable indoor air velocity u (Graph 1). Graph 1 enables to determine for the cooling mode the maximum specific volume flow rate V· in relation to the maximum Total pressure drop pt in Pa Comfort criteria max Sp tats may not exceed this value. Graph 2 enables to determine the minimum centre spacing between two outlets on the basis of the maximum specific volume 15 10 10 2.7 in m 30 -R elb ox nb 0 50 o cti e nn Co 00 ow ° 90 elb -5 R C- - -R OC O 10 30 40 50 60 ox nb 40 -3 -R OC 30 Co 90 Co -5 -R OC 00 o cti ne n 3 R- - OC ox nb ow 00 150 170 70 80 90 100 lb °e ne n 00 o cti 00 lbo e 0° w 9 5 R- - OC 20 10 25 30 40 50 150 60 200 ht H heig 200 70 80 90 100 l/s 150 170 300 400 m3/h 600 Supply air volume flow rate V· Notes: Sound power levels related to octave band centre frequen- rge 15 0 ° 90 OC 90 100 cies are available on request. The above-mentioned values for pres- cha 20 20 sure drop and sound power level apply to the standard design. Dis 25 Maximum specific cooling capacity q· in W/m2 Maximum specific volume flow rate V· Sp max in l/(s·m2) Temperature difference max –8 K –10 K 25 300 30 4 1 0 flow rate. Sound power level LWA in dB(A) ref. 10-12W specific cooling capacity and the maximum temperature difference DJ . The volume flow rate supplied to the room V· - -R OC 5 25 50 Sp max 0 30 Co o cti e nn 20 ow ox nb 30 Values for return air available on request. 100 Features 5 •• High level of thermal comfort thanks to diffuse indoor air flow 5 •• Fulfils thermal comfort criteria for commercial applications as defined in EN ISO 7730 0 0 0.1 0 0.2 0.3 0.35 a result, no or only very little dirt accumulation on the ceiling board ceilings •• For ceiling heights from 2.5 to 4.5 m 6 Minimum air outlet centre spacing tmin in m DS 4174 E www.krantz.de •• Very uniform air discharge and formation of an air cushion; as •• For mounting in suspended ceiling systems, e.g. gypsum Graph 1: Maximum specific volume flow rate p. 3 04.2013 Maximum allowable indoor air velocity u in m/s •• Steady radial air spread •• Volume flow rate range from 25 to 170 l/s [90 to 610 m³/h] •• Maximum temperature difference between the supply and in- 7 8 5 9 10 4 3 1 me flo ic volu pecif Max. s 2 20 50 w · max rate V Sp 12 14 16 2 ) 18 in l/(s·m 100 150 200 Air outlet volume flow rate V·A in l/s Graph 2: Minimum air outlet centre spacing door air ±10 K 2) •• Also usable as return air inlet •• 2 sizes available: 300 and 500 •• Low sound power level •• Low pressure drop •• Suitable for connection to a flexible duct or fitted with a connection box •• Connection box optionally available with volume flow damper adjustable at the connection spigot •• Faceplate and connection box made of galvanized sheet metal 220 •• Air distribution element made of aluminium 1) See our brochure ref. TB 69 ‘Layout specifications for thermal comfort’ 2) When heating, +10 K up to 3 m ceiling height, +5 K up to 4.5 m ceiling height 3 Circular Opticlean Type code Connection type Surface finish ––––––––– Connection type ––––––– Damper ––––––––––––– Size –––––––––––––––– Geometry –––––––––––– Opticlean –––––––––––– OC – R – ___ / _ _ – ____ O = no connection piece (suitable for connection to flexible duct) K = connection box Damper O = no volume flow damper S = with volume flow damper adjustable at spigot (only for design with connection box) Surface finish Geometry 9010 = face painted to RAL 9010, semi-matt R .... = circular faceplate = face painted to RAL …. Size 300 = Size 300 500 = Size 500 Tender text Materials: –– Faceplate made of galvanized sheet metal painted to RAL .... .... units –– Air distribution element made of aluminium Circular Opticlean with horizontal air discharge, for installation in –– Connection box made of galvanized sheet metal suspended ceiling systems made from mineral fibre or gypsum board, designed to generate a high-quality indoor air flow at low air velocities and uniform air temperatures; unobtrusive integration Make: into the suspended ceiling; strong reduction of dirt accumulation Type: KRANTZ KOMPONENTEN OC – R – ___ / _ _ – ____ on the ceiling thanks to very uniform air discharge and formation of an air cushion; also usable as return air inlet; outlet consisting of: –– circular faceplate with round staggered perforations, 3 mm in diameter, and collar –– air distribution element with top connection spigot for connection to a flexible duct –– optional connection box with lateral connection spigot and suspension brackets, optionally fitted with volume flow damper DS 4174 E p. 4 10.2011 Subject to technical alteration. www.krantz.de adjustable at the spigot. Caverion Deutschland GmbH Krantz Komponenten Uersfeld 24, 52072 Aachen, Germany Phone: +49 241 441-1, Fax: +49 241 441-555 [email protected], www.krantz.de
© Copyright 2025 Paperzz