Circular Opticlean OC-R.

Air distribution systems
Circular Opticlean OC-R-.…
DS 4174 E 04.2013
Circular Opticlean
Preliminary remark
Flexible duct connection
9
The Circular Opticlean complements KRANTZ KOMPONENTEN’s
following advantages: high level of thermal comfort, very little dirt
øD
1
5
R
HE
power level.
2
6
Construction design
The Circular Opticlean is designed for mounting in suspended ceil-
H3
4
ø A 4)
K
H
accumulation on the ceiling, low pressure drop and low sound
 H1
range of ceiling air outlets for diffuse air distribution and offers the
øE
ing systems, especially gypsum board ceilings. The circular face-
3
plate 4 has round staggered perforations whose diameter is 3 mm
and pitch 6 mm. The Circular Opticlean is connected to the duct
system via a flexible duct 9 or a connection box 8. It is fixed to the
ceiling tile using fixing clips 2.
Mode of operation
n·
2

The supply air is discharged very uniformly through the perforated
faceplate and spreads radially in the horizontal plane. As it induces
indoor air, the air flow velocity and the difference in temperature
Connection box
L
between the supply and indoor air decrease rapidly; this results
in low indoor air velocities and uniform indoor air temperatures.
The induced indoor air does not come into contact with the perfor-
8
ø D5
ated faceplate because a layer builds up under the air outlet and
acts as an air cushion. This considerably reduces the dirt accu-
H2
mulation on the ceiling which usually occurs with turbulent-flow
air outlets.
K
Many suspended ceiling systems incorporate lighting fixtures or
let fits perfectly in the overall ceiling design.
H3
loudspeakers which look like the Circular Opticlean, so this air outø A 4)
øE
B
10.2011
Applications
p. 2
–– For ceiling heights from 2.5 to 4.5 m
–– Maximum temperature difference ±10 K 1)
–– Also usable as return air inlet 2)
Key
3 Fastener for faceplate
6 Stop buffer
1 Air distribution element 4 Perforated faceplate
8 Connection box
2 Fixing clip
9 Flexible duct
5 Clamping screw
Size
1)
2)
When used as return air inlet, it may get dirty but is easy to clean
3)
Other ceiling thicknesses on request
4)
Ceiling cutout
5)
The overall height is based on a minimum bending radius of R/D = 0.5.
Smaller radii are possible depending on the type of flexible duct used.
2
ø D ø A 4)
øE
H
H1 5)
HE
l/s
m3/h
mm
mm
mm
mm
mm
mm
300
25 –   70
  90 – 250
124
300
365
65.5
30.0
250
500
70 – 170
250 – 610
199
490
565
88.2
28.5
385
Size
H2
mm
H3
mm
K 3)
mm
n·a
mm
L
mm
B
mm
ø D5
mm
Weight
kg
300
220
3.5
10 – 25
3 · 120°
190
205
124
1.04
500
320
8.0
10 – 25
4 ·   90°
265
280
199
2.65
When heating, +10 K with ceiling height up to 3 m, +5 K with ceiling
height up to 4.5 m
Volume flow rate range
www.krantz.de
DS 4174 E
–– Volume flow rate range from 25 to 170 l/s [90 to 610 m3/h]
Circular Opticlean
1)
40
The outlet layout must comply with the maximum allowable indoor air velocities u in the occupied zone in the cooling mode.
The indoor air velocity depends on the cooling load that is to be
removed from the room. The maximum specific cooling capacity
q· depends on the discharge height and the maximum allowable
indoor air velocity u (Graph 1).
Graph 1 enables to determine for the cooling mode the maximum
specific volume flow rate V·
in relation to the maximum
Total pressure drop pt in Pa
Comfort criteria
max
Sp tats
may not exceed this value.
Graph 2 enables to determine the minimum centre spacing
between two outlets on the basis of the maximum specific volume
15
10
10
2.7
in m
30
-R
elb
ox
nb
0
50
o
cti
e
nn
Co
00
ow
°
90
elb
-5
R
C-
-
-R
OC
O
10
30
40
50
60
ox
nb
40
-3
-R
OC
30
Co
90
Co
-5
-R
OC
00
o
cti
ne
n
3
R-
-
OC
ox
nb
ow
00
150 170
70 80 90 100
lb
°e
ne
n
00
o
cti
00
lbo
e
0°
w
9
5
R-
-
OC
20
10
25
30
40
50
150
60
200
ht H
heig
200
70 80 90 100
l/s 150 170
300
400 m3/h 600
Supply air volume flow rate V·
Notes: Sound power levels related to octave band centre frequen-
rge
15
0
°
90
OC
90 100
cies are available on request. The above-mentioned values for pres-
cha
20
20
sure drop and sound power level apply to the standard design.
Dis
25
Maximum specific cooling capacity q· in W/m2
Maximum specific volume flow rate V· Sp max in l/(s·m2)
Temperature difference max
–8 K –10 K
25
300
30
4
1
0
flow rate.
Sound power level LWA in dB(A) ref. 10-12W
specific cooling capacity and the maximum temperature difference DJ . The volume flow rate supplied to the room V·
-
-R
OC
5
25
50
Sp max
0
30
Co
o
cti
e
nn
20
ow
ox
nb
30
Values for return air available on request.
100
Features
5
•• High level of thermal comfort thanks to diffuse indoor air flow
5
•• Fulfils thermal comfort criteria for commercial applications as
defined in EN ISO 7730
0
0
0.1
0
0.2
0.3
0.35
a result, no or only very little dirt accumulation on the ceiling
board ceilings
•• For ceiling heights from 2.5 to 4.5 m
6
Minimum air outlet centre spacing tmin in m
DS 4174 E
www.krantz.de
•• Very uniform air discharge and formation of an air cushion; as
•• For mounting in suspended ceiling systems, e.g. gypsum
Graph 1: Maximum specific volume flow rate
p. 3
04.2013
Maximum allowable indoor air velocity u in m/s
•• Steady radial air spread
•• Volume flow rate range from 25 to 170 l/s [90 to 610 m³/h]
•• Maximum temperature difference between the supply and in-
7
8
5
9
10
4
3
1
me flo
ic volu
pecif
Max. s
2
20
50
w
· max
rate V Sp
12
14
16
2 ) 18
in l/(s·m
100
150
200
Air outlet volume flow rate V·A in l/s
Graph 2: Minimum air outlet centre spacing
door air ±10 K 2)
•• Also usable as return air inlet
•• 2 sizes available: 300 and 500
•• Low sound power level
•• Low pressure drop
•• Suitable for connection to a flexible duct or fitted with a connection box
•• Connection box optionally available with volume flow damper
adjustable at the connection spigot
•• Faceplate and connection box made of galvanized sheet metal
220
•• Air distribution element made of aluminium
1) See our brochure ref. TB 69 ‘Layout specifications for thermal comfort’
2) When heating, +10 K up to 3 m ceiling height, +5 K up to 4.5 m ceiling height
3
Circular Opticlean
Type code
Connection type
Surface finish –––––––––
Connection type –––––––
Damper –––––––––––––
Size ––––––––––––––––
Geometry ––––––––––––
Opticlean ––––––––––––
OC – R – ___ / _ _ – ____
O
= no connection piece (suitable for connection to flexible duct)
K
= connection box
Damper
O
= no volume flow damper
S
= with volume flow damper adjustable at spigot (only for design
with connection box)
Surface finish
Geometry
9010 = face painted to RAL 9010, semi-matt
R
....
= circular faceplate
= face painted to RAL ….
Size
300
= Size 300
500
= Size 500
Tender text
Materials:
–– Faceplate made of galvanized sheet metal painted to RAL ....
.... units
–– Air distribution element made of aluminium
Circular Opticlean with horizontal air discharge, for installation in
–– Connection box made of galvanized sheet metal
suspended ceiling systems made from mineral fibre or gypsum
board, designed to generate a high-quality indoor air flow at low
air velocities and uniform air temperatures; unobtrusive integration
Make: into the suspended ceiling; strong reduction of dirt accumulation
Type:
KRANTZ KOMPONENTEN
OC – R – ___ / _ _ – ____
on the ceiling thanks to very uniform air discharge and formation
of an air cushion; also usable as return air inlet;
outlet consisting of:
–– circular faceplate with round staggered perforations, 3 mm in
diameter, and collar
–– air distribution element with top connection spigot for connection to a flexible duct
–– optional connection box with lateral connection spigot and
suspension brackets, optionally fitted with volume flow damper
DS 4174 E
p. 4
10.2011
Subject to technical alteration.
www.krantz.de
adjustable at the spigot.
Caverion Deutschland GmbH