Section 4 WASTEWATER Page 4.1 Introduction.................................................................................................... 4 - 2 4.2 Design Standards ............................................................................................ 4 - 3 4.3 Flooding ......................................................................................................... 4 - 5 4.4 Tradewaste .................................................................................................... 4 - 6 4.5 Watercare Services Limited.............................................................................. 4 - 7 4.6 Backflow Prevention ........................................................................................ 4 - 8 4.7 Network Upgrade Charge ................................................................................ 4 - 9 Development and Connection Standards – Water, Wastewater and Stormwater Design and Policy Manual for Auckland City Isthmus, 4th Edition Mar 2009 Copyright © Mar 2009 Page 4 - 1 Section 4 Wastewater 4.1 Introduction Refer also to: • Section 3 Drainage, sub-section 3.14 Acquiring Access to Land; • Appendix I, Gaining Access. Definition of Wastewater Wastewater is defined as any water that has been adversely affected in quality by anthropogenic influence. This includes domestic, municipal, or industrial liquid waste products disposed of via a pipe or sewer. Wastewater Disposal The objective of the wastewater drainage system is to convey wastewater from the site efficiently and effectively while maintaining public health and minimising any adverse effects on the environment. Wastewater is disposed of either by gravity drains (public or private), pump stations (public or private), or on-site wastewater treatment plants (formerly termed septic tanks). On-site wastewater treatment plants still exist in some areas of the isthmus (Hauraki Gulf Islands excluded). As new development occurs, these should be abandoned wherever possible. No new wastewater treatment devices will be permitted on the Auckland City Isthmus. Private Pump Systems Pump systems are not generally permitted as an option for primary wastewater disposal for new developments. Any proposed private pump system is subject to Metrowater’s approval and conditions, and will only be accepted if no gravity connection is possible. The wastewater from a new development must discharge to a public wastewater pipe generally via a gravity connection. These connections may be through neighbouring sites if no other options are available. Where the proposed private gravity wastewater pipe passes through adjacent properties, written consent from affected landowners must be obtained (by the applicant) prior to Auckland City Environments (ACE) approval. Refer to Section 3 Drainage, sub-section 3.14: Acquiring Access to Land and Appendix I: Gaining Access. Key Documents • Health and Safety in Employment Act 1992 (and Amendments) http://www.legislation.co.nz/browse_vw.asp?content-set=pal_statutes • Health and Safety in Employment Regulations 1995 (and Amendments) • AS/NZS 2865:2001: Safe Working in a Confined Space • Code of Urban Subdivision and Development 1999 [Auckland City] http://www.legislation.co.nz/browse_vw.asp?content-set=pal_regs http://shop.standards.co.nz/productdetail.jsp?sku=2865%3A2001%28AS%2FNZS%29 http://www.aucklandcity.govt.nz/council/documents/subdivision/docs/codesurban.pdf • • • • Site Hazard Identification and Controls: Overview – Working in a Confined Space [Metrowater] [Hard copy only] Wastewater Design Manual 2007 [Metrowater] [Hard copy only] Draft Wastewater Pump Station Design Manual 1999 [Metrowater] [Hard copy only] Until this Manual is operative, it must be consulted in conjunction with: Foulwater Pump Station Design Manual 1989 [Auckland City] [Hard copy only] Development and Connection Standards – Water, Wastewater and Stormwater Design and Policy Manual for Auckland City Isthmus, 4th Edition Mar 2009 Copyright © Mar 2009 Page 4 - 2 Section 4 Wastewater 4.2 Design Standards Refer • • • • also to: Section 3: Drainage, sub-section 3.7 Bedding, Laying and Cover; Section 3: Drainage, sub-section 3.9 Manholes; Appendix R: Approved Materials for Drainage; Appendix T: Testing Requirements for New Public Assets. Public wastewater drainage must be designed to the minimum standards outlined below. Policy Minimum Requirements The public wastewater system must be designed for Maximum Probable Development (MPD) of the entire natural catchment and in accordance with the Wastewater Design Manual 2007 and Appendix R: Approved Materials for Drainage and Appendix T, Testing Requirements for New Public Assets. Provision must be made where relevant for pumped flows from or to adjacent land. Minimum Diameters Minimum diameters of new public wastewater pipes: • 150mm diameter: Residential areas; • 225mm diameter: Business, Commercial and Industrial areas. Approved Materials Refer to Appendix R: Approved Materials for Drainage. Reticulation Layout Manholes and pipelines must be located to minimise interference with future building, in particular: • in Residential zones: within the front, rear and side yards; • in Business zones: adjacent to road frontage boundaries; • in All zones: within common access ways. Public drains must connect, start or terminate at manholes only, unless otherwise approved by Metrowater. Design Criteria • Minimum Gradient 150mm diameter: 1 in100 or 1% (at the discretion of Metrowater, 0.8% if population served is less than 30, or at the top of the line) , refer Wastewater Design Manual • Minimum Fall Through of a Manhole: Refer to Section 3: Drainage, sub-section 3.9: Manholes; • Minimum Cover: − in private land and under footpaths: 900mm; − in road carriageways: 1200mm. Where minimum cover cannot be achieved, additional protection is required which requires specific design and approval. It is essential that the lack of cover will not compromise the future extension of the line; • Minimum Self-Cleansing Velocity: 0.75m/sec. Refer to Wastewater Design Manual 2007. Development and Connection Standards – Water, Wastewater and Stormwater Design and Policy Manual for Auckland City Isthmus, 4th Edition Mar 2009 Copyright © Mar 2009 Page 4 - 3 Section 4 Wastewater 4.2 (cont) Design Standards Policy (cont) Service Connections on New Public Wastewater Pipes Where required, all new public wastewater pipes must have approved service connections (with end caps) constructed at the time the wastewater pipe is laid. Connection to these stubs will only be made under Building Consent after the wastewater pipe is declared ‘public’. Public Wastewater Pumping Stations A new public wastewater pumping station may be considered if at least ten lots are topographically unable to be drained by gravity means. Approval will be to the standards required by Metrowater (at their discretion). A key requirement of Metrowater accepting public pump stations will be a Net Present Value (NPV) analysis by a Registered Valuer. The NPV analysis will allow Metrowater to assess the maintenance costs for the economic life of the pump station. Prior to the pump station being declared ‘public’ and being vested Metrowater may require a contribution to maintenance costs from the developer based on the NPV analysis. Key Documents • Draft Wastewater Pump Station Design Manual 1999 [Metrowater] [Hard • • • Foulwater Pump Station Design Manual 1989 [Auckland City] [Hard copy only] Wastewater Design Manual 2007 [Metrowater] [Hard copy only] Standard Specification for Construction of Gravity Drain-Pipes November 2006, [Metrowater] [Hard copy only] copy only] Until this Manual is operative, it must be consulted in conjunction with: Development and Connection Standards – Water, Wastewater and Stormwater Design and Policy Manual for Auckland City Isthmus, 4th Edition Mar 2009 Copyright © Mar 2009 Page 4 - 4 Section 4 Wastewater 4.3 Flooding Refer also to: • Section 7: Standard Drawings, 12908/244. Policy Key Documents Wastewater Surcharge All wastewater pipe fittings from proposed dwellings must be of sufficient height above the connection point to the public wastewater system, to minimise the potential for backflow through the private drainage system. Minimum elevation details (wastewater pipe to floor levels) are detailed in Section 7: Standard Drawings, 12908/244. Refer also to Building Industry Authority approved documents. • Building Act 2004 http://www.legislation.co.nz/browse_vw.asp?content-set=pal_statutes • Building Regulations 1992 (and Amendments) http://www.legislation.co.nz/browse_vw.asp?content-set=pal_regs • Health and Safety in Employment Act 1992 (and Amendments) http://www.legislation.co.nz/browse_vw.asp?content-set=pal_statutes • Health and Safety in Employment Regulations 1995 (and Amendments) http://www.legislation.co.nz/browse_vw.asp?content-set=pal_regs • Resource Management Act 1991 (and Amendments) http://www.legislation.govt.nz/libraries/contents/om_isapi.dll?clientID=2471096289&infobas e=pal_statutes.nfo&record=%7BF82ABA07%7D&hitsperheading=on&softpage=DOC • Building Controls Approved Documents [Department of Building and Housing] http://www.building.dbh.govt.nz/e/publish/publications/approved_docs/publications_approv ed_documents.shtml Development and Connection Standards – Water, Wastewater and Stormwater Design and Policy Manual for Auckland City Isthmus, 4th Edition Mar 2009 Copyright © Mar 2009 Page 4 - 5 Section 4 Wastewater 4.4 Tradewaste A Tradewaste Discharge Permit from Watercare Services Limited (WSL) is required where a proposed wastewater discharge is classified as ‘tradewaste’ under the first schedule of the Auckland Regional Council Tradewaste Bylaw 1991. WSL has the delegated authority from Auckland Regional Council to administer the Tradewaste Bylaw. Applications will specify a maximum flow rate (for example, 5 l/s) and maximum daily discharge (for example, 6 m³) and details on the type of contaminant and proposed pre-treatment systems etc. Policy Metrowater Tradewaste applications are primarily processed by Watercare Services. Details on maximum flow rates and volumes are however forwarded to Metrowater who will advise the allowable flow rates thereby ensuring the public wastewater system has sufficient capacity for the proposed tradewaste discharge. Any development work resulting in connection of new or existing wastewater systems to Watercare Service’s systems will be carried out by Metrowater. These costs will be met by the applicant. Grease Traps All Building Consents which require the installation of a grease trap, or re-approval of a grease trap, should be referred to Metrowater for approval. Generally, the grease trap should be: outside the building (where practicable); located as far as possible from the hot water source; and, should be sized as per New Zealand Building Code G13. Conditions Conditions may be imposed by Metrowater, as appropriate. Capacity Analysis A capacity analysis will be required. Environment Protection As well as the discharge quantity and flow rate, Metrowater will also consider the possible environmental effects of a proposed discharge. These include possible impacts on: people; the pipe system (such as pumps in public pump stations); proposed pre-treatment; and (in cases of overflow) the effect of the discharge on the environment. Key Documents • Local Government Act 1974 (and Amendments) http://www.legislation.co.nz/browse_vw.asp?contentset=pal_statutes&clientid=592831&viewtype=contents • Local Government Act 2002 (and Amendments) http://www.legislation.co.nz/browse_vw.asp?contentset=pal_statutes&clientid=592831&viewtype=contents • Catchment Management Plans [Auckland City Environments or Metrowater] • Trade Waste Bylaw 1991 [Auckland Regional Council] [Hard copy only] [Hard copy only] Development and Connection Standards – Water, Wastewater and Stormwater Design and Policy Manual for Auckland City Isthmus, 4th Edition Mar 2009 Copyright © Mar 2009 Page 4 - 6 Section 4 Wastewater 4.5 Watercare Services Limited WSL owns and operates the bulk trunk-water supply and wastewater drainage systems. WSL provides supply of water as well as wastewater disposal services to the Auckland region either through the territorial authority or the local city councils. Policy Auckland City Council and Watercare Services Limited (WSL) Liaison on drainage issues between Auckland City Council and WSL will be undertaken by Metrowater. Work Near Watercare Services’ Systems No works shall take place within 10m of a WSL wastewater pipe (or watermain), or 20m if blasting, without specific prior written approval from WSL. Auckland City Environments (ACE) advises all applicants of this requirement, and will not be able to process any Consent until a WSL Building Approval Permit for the proposed work has been received. Direct Private Connections to Watercare Services’ Systems No direct private connections to WSL systems are permitted. Key Documents • Building Act 2004 http://www.legislation.co.nz/browse_vw.asp?content-set=pal_statutes • Building Regulations 1992 (and Amendments) • Local Government Act 1974 (and Amendments) http://www.legislation.co.nz/browse_vw.asp?content-set=pal_regs http://www.legislation.co.nz/browse_vw.asp?contentset=pal_statutes&clientid=592831&viewtype=contents • Local Government Act 2002 (and Amendments) http://www.legislation.co.nz/browse_vw.asp?contentset=pal_statutes&clientid=592831&viewtype=contents • Resource Management Act 1991 (and Amendments) • Auckland Metropolitan Drainage Act 1960 (and Amendments) http://www.legislation.co.nz/browse_vw.asp?content-set=pal_statutes http://www.legislation.co.nz/browse_vw.asp?contentset=pal_localprivate&clientid=592831&viewtype=contents • Consolidated Bylaw 1998 (and Amendments) [Auckland City] http://www.aucklandcity.govt.nz/council/documents/bylaw/ Development and Connection Standards – Water, Wastewater and Stormwater Design and Policy Manual for Auckland City Isthmus, 4th Edition Mar 2009 Copyright © Mar 2009 Page 4 - 7 Section 4 Wastewater 4.6 Backflow Prevention Refer also to: • Section 6: Water Supply, sub-section 6.25: Backflow Prevention. Backflow or cross-connection contamination of the potable water supply must be avoided in all cases. Policy Public Pump Stations All public pump stations must have approved backflow prevention devices fitted to any water supply servicing the pump station. ‘Backflow’ signs must be installed on all pump stations. Flushing hoses connected (with backflow preventers) to the water supply must not be able to be immersed in, or contaminated with wastewater. Private Pump Stations Private wastewater pumping stations must have approved backflow prevention devices installed on any external water supply fixture servicing the pump station. Certification and Permits Annual test certification of all backflow fittings is required, and will be arranged by Metrowater’s Backflow Prevention Manager. A permit must be obtained from Metrowater prior to installing any backflow prevention device. If other works are involved however, this can form part of a Building Consent application to Auckland City Environments (ACE). An ACE Building Inspector or Building Certifier will inspect the installation of the new device. Details, including the location of the new device, will be forwarded to Metrowater’s Backflow Prevention Manager. Private Wastewater Ejector Station Any pressurised tanks discharging wastewater into the public wastewater system that utilise pumps primed with water from the public water supply system, must be fitted with backflow devices. Combined Wastewater and Stormwater Screens Water Supplies connected to chambers used for cleaning of overflow or stormwater screens must be fitted with backflow devices to ensure no contaminants may be drawn back into the water supply system. Key Documents • Health and Safety in Employment Act 1992 (and Amendments) http://www.legislation.co.nz/browse_vw.asp?content-set=pal_statutes • Health and Safety in Employment Regulations 1995 (and Amendments) http://www.legislation.co.nz/browse_vw.asp?content-set=pal_regs • Water Supplies Protection Regulations 1961 (and Amendments) (esp. § 3, 4, 5, 9) http://www.legislation.co.nz/browse_vw.asp?contentset=pal_regs&clientid=592831&viewtype=contents • Health and Safety Policy Manual [Auckland City] http://www.aucklandcity.govt.nz/council/documents/handbook/key.asp • Backflow Cross-Connection Policy [Metrowater] [Hard copy only] Development and Connection Standards – Water, Wastewater and Stormwater Design and Policy Manual for Auckland City Isthmus, 4th Edition Mar 2009 Copyright © Mar 2009 Page 4 - 8 Section 4 Wastewater 4.7 Network Upgrade Charge Refer to: • Section 2: Development, sub-section 2.14: Network Upgrade Charge. The Network Upgrade Charge is imposed by Metrowater to recover a fair share of infrastructure investment costs attributable to growth from those contributing to increased growth and demand. Policy Key Documents The Trigger for Metrowater charging a Network Upgrade Charge typically occurs when an authorisation for a new or upsized service connection (water or wastewater) is approved by Metrowater, or when a Building Consent is approved by Auckland City Council. • • Network Upgrade Charge Policy (2007) http://helios.metrowater.co.nz/SiteCollectionDocuments/Metrowater_NUC_Policy_Final_07_(3).pdf Development and Connection Standards – Water, Wastewater and Stormwater Design and Policy Manual for Auckland City Isthmus, 4th Edition Mar 2009 Copyright © Mar 2009 Page 4 - 9
© Copyright 2026 Paperzz