Planning guide Urban III for glass panel (t: 1/4“ - 1/2“ ) min. 1“ 25 A sliding glass panel 13⁄8“ 35 fixed glass panel 27⁄8“ 73 31⁄16“ 78 max. 132 lb TH FGH H 1 9⁄16“ 40 TH ¼“-½“ ¼“-½“ inside outside F= 5⁄16 min. 5⁄64“ 2 8 DB > 215⁄8“ FGH track rail length L = A - 15/16“ (24mm) B Note: Reduce top track length opposite of pre-drilled holes. 3¾“ 95 65_30_00.0117_US_Urban3_2016_03_19jb The standard track rails can, if necessary, shorten on the door side. By shortening the track rail, the passage width DB changes. The door width TB is to reduce the same dimension to be shortened. The dimension to the fixed glass panel FGB remains unchanged. A 315⁄16“ 100 315⁄16“ 100 *315⁄16“ *100 x=? *315⁄16“ *100 B FGB TB © by ABP-Beyerle GmbH - technical amendments reserved - all dimensions in 4 1⁄8“ 104 mm acurate; inch approx x=? *recommended A = DLO-W (Day Light Opening - Width) L = track rail length TB = sliding glass panel width TH = sliding glass panel height FGB = fixed glass panel width FGH = fixed glass panel height DB = Clear opening width H = track rail height x = gap size min. 5/64“ F = Horizontal gap at bottom of sliding glas panel Planning guide Urban III for glass panel (t: 1/4“ - 1/2“ ) calculation door glass panel heigth (TH): FGH = H + 2 7⁄8“- 5⁄64“ TH = FGH = 315⁄16“ 100 13⁄8“ 35 A calculation fixed glass panel heigth (FGH): TH = H - F + 2 7⁄8“ 315⁄16“ 100 *315⁄16“ *100 3 1⁄16“ 78 B TB FGB DB 60“ 59 1⁄16“ 22 5⁄8“ 32 5⁄16“ 30 ½“ 27 3⁄8“ 71 19⁄16“ 70 7⁄8“ 28 9⁄16“ 38 3⁄16“ 36 7⁄16“ 33 5⁄16“ *315⁄16“ *100 B for custom special lenght only: calculation glass panel width: TB = A/2 + 2 5⁄16“ FGB = A/2 + 1/2“ B = FGB - 7 7⁄8“ DB = A - FGB - 2 3⁄16“ - x Ø 5/8“ Ø16 ex. A = 68 3⁄8“ TB = 68 3⁄8“ /2 + 2 5⁄16“ = 36 ½“ FGB = 68 3⁄8“ /2 + 1/2“ = 34 11⁄16“ B = 34 11⁄16 - 7 7⁄8“ = 26 13⁄16“ DB = 68 3⁄8“ - 34 11⁄16“ - 2 3⁄16“ - 5⁄64“ = 31 27⁄64“ max. 132 lb knob/ flush pull/ handle bar L 48 3⁄16“ 47 ¼“ 16 9⁄16“ 26 3⁄8“ 24 7⁄16“ 21 11⁄16“ 2 7⁄8“ 73 Ø 5/8“ Ø 16 ? standard length: calculation for special lenght only: TH FGH A = H = TB = FGB = 65_30_00.0117_US_Urban3_2016_03_19jb B = DB = TB TB = A/2 + 2 5⁄16“ Beyerle US L.L.C. 5126 S Royal Atlanta Dr. , Tucker, GA 30084 Phone (770) 349 - 6324 , Fax (770) 934 - 3384 , mail: [email protected], www.beyerle-us.com FGB FGB = A/2 + 1/2“ technical changes reserved - dimension in © by ABP-Beyerle GmbH *recommended mm acurate; inch approx A = DLO-W (Day Light Opening - Width) L = track rail length TB = sliding glass panel width TH = sliding glass panel height FGB = fixed glass panel width FGH = fixed glass panel height DB = Clear opening width H = track rail height x = gap size min. 5/64“ F = Horizontal gap at bottom of sliding glas panel
© Copyright 2026 Paperzz