Planning guide Urban III

Planning guide Urban III
for glass panel (t: 1/4“ - 1/2“ )
min. 1“
25
A
sliding glass panel
13⁄8“
35
fixed glass panel
27⁄8“
73
31⁄16“
78
max. 132 lb
TH
FGH
H
1 9⁄16“
40
TH
¼“-½“
¼“-½“
inside
outside
F=
5⁄16
min.
5⁄64“
2
8
DB > 215⁄8“
FGH
track rail length L = A - 15/16“ (24mm)
B
Note:
Reduce top track length opposite of pre-drilled holes.
3¾“
95
65_30_00.0117_US_Urban3_2016_03_19jb
The standard track rails can, if necessary, shorten on the door side.
By shortening the track rail, the passage width DB changes.
The door width TB is to reduce the same dimension to be shortened.
The dimension to the fixed glass panel FGB remains unchanged.
A
315⁄16“
100
315⁄16“
100
*315⁄16“
*100
x=?
*315⁄16“
*100
B
FGB
TB
© by ABP-Beyerle GmbH - technical amendments reserved - all dimensions in
4 1⁄8“
104
mm acurate; inch approx
x=?
*recommended
A = DLO-W (Day Light Opening - Width)
L = track rail length
TB = sliding glass panel width
TH = sliding glass panel height
FGB = fixed glass panel width
FGH = fixed glass panel height
DB = Clear opening width
H = track rail height
x = gap size min. 5/64“
F = Horizontal gap at bottom
of sliding glas panel
Planning guide Urban III
for glass panel (t: 1/4“ - 1/2“ )
calculation door glass panel heigth (TH):
FGH = H + 2 7⁄8“- 5⁄64“
TH =
FGH =
315⁄16“
100
13⁄8“
35
A
calculation fixed glass panel heigth (FGH):
TH = H - F + 2 7⁄8“
315⁄16“
100
*315⁄16“
*100
3 1⁄16“
78
B
TB
FGB
DB
60“ 59 1⁄16“ 22 5⁄8“ 32 5⁄16“ 30 ½“ 27 3⁄8“
71 19⁄16“ 70 7⁄8“ 28 9⁄16“ 38 3⁄16“ 36 7⁄16“ 33 5⁄16“
*315⁄16“
*100
B
for custom special lenght only:
calculation glass panel width:
TB = A/2 + 2 5⁄16“
FGB = A/2 + 1/2“
B = FGB - 7 7⁄8“
DB = A - FGB - 2 3⁄16“ - x
Ø 5/8“
Ø16
ex.
A = 68 3⁄8“
TB = 68 3⁄8“ /2 + 2 5⁄16“ = 36 ½“
FGB = 68 3⁄8“ /2 + 1/2“ = 34 11⁄16“
B = 34 11⁄16 - 7 7⁄8“ = 26 13⁄16“
DB = 68 3⁄8“ - 34 11⁄16“ - 2 3⁄16“ - 5⁄64“ = 31 27⁄64“
max. 132 lb
knob/
flush pull/
handle bar
L
48 3⁄16“ 47 ¼“ 16 9⁄16“ 26 3⁄8“ 24 7⁄16“ 21 11⁄16“
2 7⁄8“
73
Ø 5/8“
Ø 16
?
standard length:
calculation for special lenght only:
TH
FGH
A
=
H
=
TB =
FGB =
65_30_00.0117_US_Urban3_2016_03_19jb
B
=
DB =
TB
TB = A/2 + 2 5⁄16“
Beyerle US L.L.C.
5126 S Royal Atlanta Dr. , Tucker, GA 30084
Phone (770) 349 - 6324 , Fax (770) 934 - 3384 , mail: [email protected], www.beyerle-us.com
FGB
FGB = A/2 + 1/2“
technical changes reserved - dimension in
© by ABP-Beyerle GmbH
*recommended
mm acurate; inch approx
A = DLO-W (Day Light Opening - Width)
L = track rail length
TB = sliding glass panel width
TH = sliding glass panel height
FGB = fixed glass panel width
FGH = fixed glass panel height
DB = Clear opening width
H = track rail height
x = gap size min. 5/64“
F = Horizontal gap at bottom
of sliding glas panel