This drawing must be read in conjunction with the relevant Residual Design Hazard Schedule 100 x 25mm SW C16 longitudinal bracing fixed to trusses @ ridge node point. Roof design to allow for provision of future hoist Elevations Notes 1. Kitchen extract when ceiling mounted Type and style of roof tiles and facing materials including external features such as canopies, cills, heads, fasica, windows and doors as site specification and to Local Authority Approval. SHOWN INDICATIVE ONLY ON THIS PLAN 2. Provide Code 4 lead flashings with cavity trays over at roof/wall abutments. 3. Refer to Brick Rod for setting out height to extract fans and flues. 4. All windows to first floor habitable rooms to be escape windows with a minimum unobstructed Alternate flue location Bathroom extract when wall mounted 450mm insulation to roof 30 x 5mm galv. mild steel gable peak & ceiling line straps. Straps to extend over min. 3 No. Trusses @ max. 2m crs with 75 x 50mm sw noggins below See separate drawing for eaves detail MJ All first and second floor windows to have easy clean hinges and to be fitted with window opening restrictiors. Escape windows to be fitted with an approved window opening restrictor to the satisfaction of Building Control. Where Lifetimes homes applies all window handles to be no higher than 1200mm from FFL. 6. When using intermittent extract fans, please refer to table for background (trickle) ventilation requirements. 7. Tile vents to be provided for bathroom extract in mid terrace or when adjacent a party wall, or when SP requires venting - see general notes (item 3). 8. Extract from cooker hood Maintain manufacturers required clearances from edge of boiler flue - generally 300mm directly below, above or alongside an opening window, air vent or other ventilation opening, 300mm(*) from an internal / external corner, 75mm(*) below RWP's and soil pipes, 200mm(*) below eaves and 150mm(*) horizontally from a RWP or Soil Pipe. 100 x 25mm SW C16 longitudinal bracing fixed to trusses @ rafter node point. 100 x 25mm SW C16 longitudinal binders fixed to trusses @ ceiling node points. least 450mm high and 450mm wide. The bottom of the openable area should not be more than 1100mm above the floor. 5. Provide eaves ventilation equivalent to a continuous 10mm gap with supplementary ridge level ventilation (via dry ridge) equivalent to a continuous 5mm gap. Ensure that rafter rolls are installed at the eaves to maintain the air path. Rafter roll to extend above and below insulation (use appropriate lengths as required) W 100 x 50mm wallplate. 15mm plasterboard and skim to ceilings. Landing Bed 1 E* FFL E* G* G E E Window handles to be no higher than 1200mm from FFL For fixing detail of stair refer to 2012/SD/007 G G* (As) Periscope ventilator RWP (Opp) (Opp) Alternate Gas Meter location Front Elevation 1:100 Level Entry Required (As) RWP Level Entry Required Rear Elevation 1:100 Side Elevation 1:100 Side Elevation 1:100 Notes and dimensions apply to both sides (both As and Opp layouts) Shown separate for clarity 150mm and 300mm zones indicated roundflue on elevations. Bed 2 Hall Ceilings to be under drawn with 15mm board and skim finish to provide 1/2 hour fire resistance & 40dB Lounge St DPM to be lapped up edge of floor slab & lapped under horizontal DPC at all internal loadbearing walls where provided. (*) One reduction down to 25mm is allowable per install - refer to manufactures details 1200x2000 min External Level Landing Roof Plan Notes 1200x2000 min External Level Landing 600mm deep canopy and 1.2x1.2m level landing required where parking is closest to secondary entrance Level Entry Required Coat Hooks to be provided adjacent external doors (only front door when mid terrace) Level access No services (i.e.pipe runs, electrical cabling etc) are to be installed in the floor void over the future lift position Lounge Stud walls to WC to be lined with 18mm WBP plywood internally in addition to the plasterboard for future grab rail installation Bathroom sanitaryware to comprise: Twyford Alcona Flushwise WC (AR1148) and Twyford Option 550 Basin (OT4211) with Twyford Option Pedestal (OT4910) and Twyford Celtic 1700x700 140Ltr bath (CE1572) with side panel Use ceiling mounted extract fan ducted to rear elevation when WC is adjacent a party wall and window is omitted WC Lobby WC ST ST 3. 4. 5. C C 2 S Hall Hall This drawing to be used in conjunction with suppliers joist, stairs, truss and kitchen layouts and with company standard details. 2. The top of all separating / compartment walls (party walls) are to be fire stopped with a minimum of one layer of 25mm thick mineral wool laid above and below roofing membrane. 3. Self sealing waste valves to be utilised on all appliances discharging into soil stacks / rest bends. Soil pipe only to be open vented (900mm above openings or at tile/soffit) at the head of the drain serving 5 to 10 dwellings, and at the head and mid-point of any drain serving 11 to 20 dwellings. In all other instances a stub stack should be provided. See site specific drainage / external works plan for further details. Wall switch Smoke detector position with mains power supply and battery backup. To be interlinked as BS:5446. To be 300mm from light fitting and wall. 4. Internal soil pipes to be wrapped in minimum 25mm mineral fibre quilt and fire stopped where it passes through intermediate floors and be encased full height with 2 layers 12.5mm plasterboard on 38x38mm sw framing in all cases. Heat detector position.To have mains power supply and battery backup and to be interlinked with smoke alarm. To be 300mm from light fitting and wall. 5. All drainage runs to first and second floor to be discharged to soil stack via floor void. No boxing / pipe work above floor, unless otherwise shown / where indicated. Waste pipes to be boxed out using 6mm ply on 38x38mm sw framing. 6. Refer to manufacturers literature for minimum required distances from inside face of support to the nearest edge of the hole when notching and drilling joists. 7. All dimensions are to the face of structure (i.e., timber stud / joists / truss / unfinished face of blockwork) unless otherwise noted. 8. Consumer Unit to be set between 1350 - 1450mm from FFL High level socket Twin high level sockets Telephone point 600 B/U Recycle Bin under sink E* Level access MJ 600 min depth canopy covering MJ Cladding fixed to block work Cladding fixed to block work (Opp) (AS) First Floor Plan 1:50 100mm dia rest bend for future shower. To be capped off. 1:20 Ensure DPM is lapped up side of floor slab & returned under blockwork Gutters and rainwater pipes sized in accordance with AD/H3. Manufacturer to check dimensions prior to fabrication. RL = Rafter Longitudinal bracing 100 x 25mm SW C16 fixed to trusses @ rafter node point 3. 100 x 50mm sw wallplates throughout. 4. All roof bracing to comply with BS:5268. All timber bracing to trussed rafters to be 100x25mm min. C16 grade timber and nailed twice into each trussed rafter, and to the wall plate. Nailing should be 3.35mm (10 gauge) x 65mm long galvanized round wire nails. 30x5mm galv. mild steel gable peak & ceiling line straps. Straps to extend over min. 3 No. Trusses @ max. 2m crs with 75x50mm sw noggins below 7. WD = Web Raking Brace 100 x 25mm SW C16 Roof Access E E WL = Web Longitudinal Bracing 100 x 25mm SW C16 to trusses @ ridge node point. E* E* G* Foundation Plan 1:100 9. 10. The top of all party walls to be fire stopped with minimum of 25mm thick mineral wool laid above & below roofing membrane. Gable peak straps Ceiling line straps 100 x 50mm sw wallplate Loft access hatch Provide Masonry bed joint reinforcement ANCON AMR 3.0 (or similar) in outer leaf. HQI SCORES Bed reinforcement every 450mm vertical centers to outer leaf of blockwork where wall are rendered and width is spaning 6 - 9 metres. increase to 225 centres when 9 - 6 metres. Place 2 courses under and and above windows in render at 225 courses, extend 600 behond jambs. In accordance with render manufacturer's recommendations Housing Quality Indicator (HQI) Design Quality Standards min. score Design Quality Standards Achieved Unit Size Unit Layout 41 41 32 56 Unit Services 22 35 102.5mm Facing brick RD = Rafter Diagonal Provide 100 x 25mm SW C16 diagonal bracing fixed to underside of rafters Adjacent ends of bracing members are to be fixed in close proximity to one another. Notes and dimensions apply to both sides (both As and Opp layouts) Shown separate for clarity Fused spur for boiler to be located within boiler housing where possible. When constructing dwelling from Timber Frame all sockets on the party wall are to be staggered or located on external wall. Ceiling rose light point - low energy IPX4 rated light fitting - low energy Wall mounted light point - low energy For the type and fitting of energy efficient lighting, please refer to separate specification for further details. 1 0.2 -- 1.50 1.50 Understair Store 0.400 0.800 2 0.6 0.30 0.90 1.20 Bulkhead Cupboard 0.800 0.934 3 2.2 0.30 0.80* 1.50 Total Area of Shelving to be installed 3.08 Total Area Required 3.00 0.720 0.720 0.52 1 Total Area of Tall Storage Provided 0.52 Total Area of Tall Storage Required 0.50 100mm Lightwieght Aircrete (AAC) blockwork kg/m Roof Truss designs to allow for potential hoist load Roof Plan 1:100 100mm Dense Concrete Aggregate blockwork 1350 - 1600kg/m 3 Additional restraint straps may be required to separating / party wall - refer to specification for further details 63mm CLS Stud with 12.5mm plaster board & 2.5mm skim to each side Acoustic Insulated partition to provide 40dB sound reduction PLOT NUMBERS AREA OF BACKGROUND VENTILATORS (TRICKLE VENTS) TO WINDOWS / FRENCH DOORS REQUIRED SYSTEM 1 APPROACH (ADF TABLE 5.2a) Window Ref W01 / W02 D03 / D04 W03 / W04 W05 / W06 W07 / W10 W08 / W9 Ventilator area provided Equivalent ventilator area req'd - min occupancy Equivalent ventilator area req'd - max occupancy Min equivalent area required per window 15000 15000 2500 15000 2500 15000 65000 45000 60000 Tenure Affordable DQS Yes Lifetime Homes House Type L Structural Stud - See Eastwood and Partners detail 32787/001B MJ As 20 Yes 49 77 Opp 21 26 50 78 79 Cooker hood extract vented to external wall. Ventilation rates as below. Ceiling mounted extract fan ducted to outside air. IPX4 rated and RCD protected. Ventilation rates as below. Intermittent Fan Ventilation Rate / Switching Requirements Kitchen - 60ltrs/sec [Ceiling / Wall mounted] To be used in conjunction with re-circulating cooker hood and controlled with separate wall switch. Kitchen - 30ltrs/sec [Cooker hood] When vented to outside air via external wall. Controlled via grid switch and connected to high level socket. Bathroom - 15ltrs/sec [Ceiling / Wall Mounted] Where no windows are provided then fan is to have a 15min overrun and be linked to the light switch, otherwise control via separate wall switch. WC - 6lts/sec [Ceiling Mounted] To be linked to light switch and have 15min overrun when no window provided. Can be omitted when window provided. When using intermittent fans please refer to separate table for the total equivalent area of background (trickle) ventilators required to the windows and French doors. GP Radiator Position. Where Lifetime Homes applies, TRV's to be located between 450mm - 1200mm high and 300mm from an internal corner 4 Bed Spaces Wall mounted balanced flue boiler to be gas fired, for size and type refer to heating design All Dwellings Plinth heater Cubic Storage Capacity Provided 1.68 Additional Larder Storage Understairs 0.57 Total Storage Provided 2.25 Minimum Cubic Capacity Required 2.10 Length of fitments provided 5.94 M Length of fitments Required 5.63 M P1 4 Person Dwelling Notes Kitchen supplier to achieve minimum capacity and state actual Cubic Capacity on kitchen layouts P2 When constructing dwelling from Timber Frame no gas / gas runs are to be incorporated within the party wall. Wall mounted meter position (E - Electricity / G - Gas).To have E lintel, weep vents and DPC over * Symbol denotes alternate meter location if built as mid G* terraced Floor mounted gas meter box (* symbol denotes alternate meter location if built as mid terraced) G* Movement Joint ANCON AMR 3.0 Bed Reinforcement 'Approved' foundation grade blockwork/common brickwork below ground level. Blockwork to be minimum 7N/mm2. Lean mix cavity fill up to 225mm minimum below d.p.c. 4 courses minimum facing brick below d.p.c. to outer leaf of external walls. Provide a minimum clear cavity of minimum 225mm from dpc to top of cavity fill. In relation to party walls a clear 225mm is required to underside of slab and trench blocks Bathrooms and En-Suites to have moisture resistant plasterboard installed throughout excluding ceilings and to achieve the required sound insulation levels, as above. External Wall - Eternit Cladding on Blockwork Outerleaf Outerleaf : Eternit cladding on 50x50mm vertical counter battens (EPDM over battons at joints )on 100mm dense concrete aggregate blockwork with a minimum strength of cement:lime:sand. Also refer to Structural Engineers drawings) Cavity: - As exterior brick Cavity Walls Inner leaf : - As exterior brick Cavity Walls For Eternit bay on timber plywood timber framing refer to A(21)014 Copyright in this drawing remains the property of BM3 Architecture Limited. Do not scale this drawing. Work to figured dimensions only. Contractors and consultants are to advise BM3 Architecture Limited of any discrepancies. revision NOTE: Where movement joints are between 6-9m bed reinforcement should be provided in outer leaf at 450mm horizontal centers. (unless otherwise detailed or as recommended by render manufacturer) 24.03.14 25.07.14 drawn chckd RW BG JJ JJ Construction Issue project PASTON RESERVE PETERBOROUGH CiSfb element SUPERSTRUCTURE drawing HOUSE TYPE L WORKING DRAWING Party Walls 300mm cavity wall construction comprising of 2no. leaves of 100mm Dense Concrete blockwork with a density of 1350 - 1600kg/m 3 in 225mm courses with a 100mm cavity with 12.5mm plasterboard (nominal 9.8kg/m2) mounted on dabs. Cavities are to be filled with 100mm Isover RD Party Wall Roll (ensuring that no gaps remain) Robust Standard Detail E-WM-20. 2 Bed 4 Person LTH/DQS drawn by Outerleaf: 15-20mm through colour cement based render by Weber Monocouche (or equal approved) on 100mm dense concrete blockwork with a minimum strength of (minimum mortar strength of 1:1:6 cement:lime:sand. Also refer to Structural Engineers drawings) Cavity: 100mm minimum width fully insulated, insulation to have a thermal conductivity of 0.036 w/mK or better and to comply with the requirements of the Building Regulations Part E 2010. Cavity insulation to be taken down to top of weak mix cavity fill, and where extra external facings are required insulation to be taken to a minimum of 225mm below DPC level. Innerleaf: 100mm 450-800 kg/m density blockwork with a thermal conductivity of 0.11W/mK with 12.5mm plasterboard on dabs to give an overall wall 'U' value of 0.25 W/m 2 date A: NHBC Building Control Issue B: Air brick, light and movement joints added, notes updated ALL ELECTRICAL INSTALLATIONS TO BE IN ACCORDANCE WITH BS:7671 (latest edition) Exterior Render Cavity Walls PROMISE. DELIVERED. Notes Programmable Room Thermostat (P1 = Zone 1, P2 = Zone 2) Motorised port valves and wiring centre for zone controls (to be installed at low level) 4 Person Dwelling * Bottom of cupboard to be classed as 1st shelf Cavity: 100mm minimum width fully insulated, insulation to have a thermal conductivity of 0.036 w/mK or better and to comply with the requirements of the Building Regulations Part E 2010. Cavity insulation to be taken down to top of weak mix cavity fill, and where extra external facings are required insulation to be taken to a minimum of 225mm below DPC level. Innerleaf: 100mm 450-800 kg/m density blockwork with a thermal conductivity of 0.11W/mK with 12.5mm plasterboard on dabs to give an overall wall 'U' value of 0.25 W/m 2 . Keepmoat Gas point Exterior brick Cavity Walls Wall Types For alternative or 'Specialist' bracing refer to Truss Manufacturers or Engineers specific details. Restraint straps to be provided where highlighted within separate specification notes. 0.400 0.500 CL = Ceiling Longitudinal bracing 100 x 25mm SW C16 fixed to trusses @ ceiling node points. Long bracing members may be lap jointed, providing the overlap is nailed to at least 2 No. roof truss members. G G 8. Rainwater pipe with access gully Frame out with min 38x38mm CLS studwork and clad with 18mm WBP Ply and 12.5mm plasterboard and skim. Boxing to be 950mm high (finished). SP to terminate at tile vent, only where required - see general notes (items 3 & 4) Roof Access Location Understair Store Understair Store CB = Web Chevron Brace 100 x 25mm SW C16 No longitudinal or diagonal bracing to penetrate any separating / party wall. Longitudinal bracing to tightly abut separating / party wall and be in line or nearly in line on both sides of separating / party wall. Storage Requirements General All roof trusses to be @ 600mm crs max. & fixed in accordance with BS:5268. 2. 6. (Opp) Bathroom WC Boxing Detail Roof Plan Notes Foundations to be taken down to a level below invert of any adjacent drainage. All services to pass through wall above foundation - provide PCC lintel over services where they pass through walls. Provide switches and socket outlets for lighting and other equipment in all habitable rooms at appropriate heights between 450mm and 1200mm from FFL (and 300mm from an internal corner when Lifetimes Homes applies) Wall mounted extract fan position with switched control. IPX4 rated and RCD protected. Ventilation rates as below. Rockpanel Cladding fixed to block work Render Notes and dimensions apply to both sides (both As and Opp layouts) Shown separate for clarity 5. H C Spacing (M) 1200x1200 min External Level Landing (AS) Ground Floor Plan 1:50 Roof truss design to allow for potential hoist loading over bedroom and bathroom G* Render S Bulkhead light point - low energy Bed 1 Number of shelves 1200x1200 min External Level Landing Bed 1 Length (M) G* Use Twford Option 550 basin and pedestal in bathroom to ensure that basin doesn't project into WC approach zone by more than 200mm Consumer unit (* symbol denotes alternate location) Isolator switch for extract fans M Recycle Bin under sink Level access Grid switched spur (above worktop) CSU W 600 B/U E* W Width (M) W GP Cladding fixed to block work G* General Notes 1. Twin low level sockets Flush to be central on cistern S M Design should be in accordance with relevant Building Regulations (Section A1/2 Section 2E) and other statutory requirements with min. cover in accordance with BS 8004:1986 and BS 8110:1997 For sites implementing a beam and block floor, please refer to beam and block manufacturers details / drawings for sleeper wall requirements. 600 B/U M W (Shelving) 1500 t.c Tracking hoist P1 2 Foundations to be to the satisfaction of the Building Inspector. Span of beam and block suspended ground floor Stud walls to the bathroom to be lined with 18mm WBP plywood internally in addition to the plasterboard for future grab rail installation Tall Alternative boiler flue location and meter locations P2 Cladding fixed to block work P1 600 B/U Cladding fixed to block work Ceiling mounted extract fan and re-circulating cooker hood to be used when it is not possible to vent cooker hood to outside air when adjacent to party wall. Preferred boiler flue location and meter locations P2 Kitchen/ Dining Foundations to be of a site specific design to suit individual site conditions, as produced and approved by site engineering consultant. Foundation Key Bathroom Roof Access Occasional Cot Space Foundation Notes 2. Roof Access FF 1. 1. Bathroom Lobby Kitchen/ Dining GP Provide single socket at high level directly above appliance to isolate the hood for maintenance Low level socket Use wall mounted extract fan to bathroom wherever possible. When adjacent a party wall then a ceiling mounted extract fan should be used in lieu of a wall mounted fan and be ducted to a tile vent on rear face of roof. Self sealing waste valves to be utilised on all appliances discharging into soil stacks. M G Block Brick -Block -Block Beam Door Doors Window Lintel beam Hanger Truss Tilse --Unit Worktop Stair Door Boiler Radiator Basin Bath Cistern -Hatch Slab All drainage runs at first floor to be discharged to soil stack via floor void. 2 Kitchen Double socket for oven and hob ignition Type of ground floor as site specification. Shown indicative only Fixed to wall between 900-1000mm above pitch line M&E Legend & Notes S M E Per 21.3 2.5 -7.7 -2.0 112.2 30.0 57.0 12.0 10.4 52.0 2.0 41.0 7.5 --30.3 69.8 96.0 15.0 31.5 25.0 15.6 19.5 19.0 -4.8 15.0 Landing SP 500 B/U G Max Weight (Kg) Landing 2 FF E Element Foundation Blocks Facing Material - Brickwork Facing Material - Stonework Blockwork Celcon Solar Blockwork Polystyrene Block Flooring Pre-stressed Ground Floor Beam External Doors French Doors Windows Lintels I-Beam Joist Hangers Roof Trusses Roof Tile GRP Canopy GRP Dormer Kitchen Units Worktop Staircase Internal Doors Boiler Radiator Wash Hand Basin Bath Toilet (Cistern) Shower Tray Loft Hatch Paving Slabs 450x450mm S Full height opening between nibs Drawers of varying height to be provided to kitchen as well as secure store for the storage of harmful substances. Stair design to provide a clear width of 900mm when measured 450mm above pitch line (excluding newel) Cooker control point w/ socket Switch fused spur 1500 t.c Larder Space Coat Hooks KEY WEIGHTS TABLE TYPE 740 Soil pipe to be terminated below bath at low level unless required to be open vented (see general notes - item 3). Where soil pipe is to be open vented it should terminate via a tile vent with full height boxing. Boxing should be sized to allow for use of a wall mounted fan where installed. 700 x 1100 dressing zone Washer Space Dishwasher Space Fridge Freezer Space Slim Dishwasher Space SP Tracking hoist W D FF SD Future Lift Position SP Flush to be central on cistern Stud walls in the Bathroom and WC to be lined internally with 18mm WBP plywood in addition to plasterboard on internal stud partitions for future grab rails 700 x 1100 dressing zone SP Wider linings to doors D10 & D18 (111mm o/a internal partitions to WC & Bathrooms) 203.62mm 227mm 900 mm TV aerial socket CSU 6. Bed 2 Visitors Chair WC sanitaryware to comprise: Twyford Alcona Flushwise WC (AR1148) and Twyford Optimise Short Project Basin (GP4051) Roof Truss design to allow for potential hoist load Bed 2 Future Lift Position 700 x 1100 dressing zone 5. Future Lift Position Cladding fixed to block work 4. Future Lift Position Cladding fixed to block work 3. 2000 x 2500 activity zone CSU 2. Balustrade to top of stair opening only. Newel to be fixed to side of joists as detail on 2012/SD/007 - additional TGI blocking required. - 700 x 1100 dressing zone Top Shelf to be Fixed at: 1. Stairs Rise Going O/A String Pitch Handrail (Home Office) 1500 t.c Bottom Shelf to be fixed at: Type Specific Notes Spur for Future Fire Lounge (Home Office) Living Room Home Office Required Daylight factor 1.5% Average daylight Factor 2.59%. Section 1:50 Level access Foundation type & design to suit ground conditions & CP2004 See Engineers details where provided. SJK scale checked JJ date VARIOUS@A1 16.01.2014 job number 60006 drawing number L(2-)010 revision B
© Copyright 2025 Paperzz