GB B.E.G. LUXOMAT ® PD9-1C(-GH)-FC Installation and Operating Instruction for B.E.G. - Occupancy detectors PD9-1C (-GH)-FC A circular opening of diameter min. 34 mm must be produced in the ceiling. Having connected the cables in accordance with the regulations, connect the power supply via the RJ11 plug. Therefore, open the power supply with the help of the screws and close it afterwards. After that, put the power supply through the opening in the ceiling and mount the sensor onto the ceiling according to figure. Zeit Lux TEST 30sec 1min 2 4 6 8 30 12 TIME Zeit TEST 30sec 1min 2 4 6 8 200 TIME 600 2000 1200 LUX 6. Article / Part-Nr. / Accessory Type Follow-up time for light control 2000 The time can be set infinitely variably at between 200 1200 30 seconds and 600 30 minutes. Symbol : LUXImpulse < 1 sec. Symbol TEST: Test mode (Every movement switches on the light for a period of 1 second, switching it off for a period of 2 seconds after that regardless of the level of brightness) Lux 30 12 RAL9010 RAL9006 92902 92903 PD9-1C-GH-FC 92934 92935 Accessory: Wire basket BSK Coverring for PD9 white Coverring for PD9 silver Coverring for PD9 anthracite Blind GH white 92199 92238 92237 92235 33207 7. Technical data Connection of sensor and power supply by means of telephone plug R J11 Declaration of Conformity: The product complies with the low voltage recommendation 2006/95/EC and the EMV recommendation 2004/108/EC. PD9-1C PD9-1C-GH-FC 25 25 45 45 166 mm 24 mm 24 mm 9. Range of Coverage 1. Lamp does not light up PD9-1C-GH-FC Lamp may be defect: Replace lamps 9,00 m RJ No mains connection/power: Check connection and mains fuse by qualified electrician Incorrect setting of CDS twilight threshold: Correct setting of CDS threshold Lens of sensor unit obstructed by dirt or other objects: Clean lens, remove objects 360° 2. Lamp turns ON too late or detection range too small LUXOMAT® PD9-1C-GH-FC is mounted too high: See table of mounting heights. Correct mounting if required. 5,40 m 3. Lamp stays ON continuously Continuous thermal activity detected ie fan, central heating ducts, animals within detection area: Remove heatsource. Check proper function of LUXOMAT® PD9-1C-GH-FC by covering the fresnel-lens. After expiry of delay timer, has to turn OFF lighting. PD9-1C 2.50 m RJ LUXOMAT® PD9-1C-GH-FC connected in parallel to a manual override switch: Connect switch correctly 4. Unintended switching of light Movement of heat source within detection area: Check on presence of animals, fans or heaters 2 3 m 10 Power supply:230 V~ ±10 % Power consumption: < 1W Ambient temperature: -25°C – +50°C Degree of protection/class: IP20 / II / CE Settings: Settings made manually using potentiometer Light values: 10 - 2000 Lux Area of coverage: circular 360° Range Ø H 2.50 m / T = 18°C: PD9-1C-FC seated 2.50 m / tangential 10 m / radial 6 m PD9-1C-GH-FCmax. Ø 5.40 m Recommended height for mounting: PD9-1C-FC 2 - 3m PD9-1C-GH-FC 5 - 10 m One channel to switch the lighting Type of contact:NOC/with pretravel tungsten contact 1000 W, cos ϕ=1 / Contact load: 500 W, cos ϕ= 0,5 Time-settings: 30 sec. - 30 min. / Test Dimensions PD9-1C-FC Ø 45 x H 12 mm PD9-1C-GH-FC Ø 45 x H 40 mm Power supply L 165 x W 24 x H 24 mm 5. Dimensions Twilight-switch for light control The switch-on value for the light can be set at between 10 and 2000 Lux. Using the rotary control, the luminance set points can be set as desired. Symbol : Night-time operation Symbol : Daytime /Night-time operation 8. Trouble shooting PD9-1C-FC In case the sensing area of the LUXOMAT® PD9-1C(-GH)-FC is too large or areas are being covered that should not be monitored, the range can be reduced or limited through use of the enclosed masking clips. m 4. Putting into operation / Settings The LUXOMAT® PD9-1C (-GH) enters an initial 60-second self-test cycle, when the supply is first connected. The occupancy detector is ready for operation. L L' N 5,4 0 Disconnect supply before installing! 3. E xclude sources of interference 16 Work on the 230 V mains supply may only be carried out by qualified professionals or by instructed persons under the direction and supervision of qualified skilled electrical personnel in accordance with electrotechnical regulations. The detector has been designed and developed specifically for installation in suspended ceilings. 2c. Self test cycle 24 34 mm 32 22 - 30 mm 2b. Connecting terminals 16 2a. Installation 12 1. Mounting preparations 1 1 2 3 360° quer zum Melder Walking across gehen frontal zumtowards Melder gehen Walking Unterkriechschutz Smaller motions 4m 6m 10 m 10. Wiring diagrams Standard mode with 1-channel motion detector L N E1 N L L΄΄ C1 Standard mode with 1-channel motion detector with permanent light function L N E1 S1 N L L΄΄ C1 optional: S1 = switch for permanent light RC = RC-suppression kit if required Standard mode with 1-channel motion detector with NC pushbutton L N T1 N T1 = NC button additionManual switching ally possible (press opener approx. 2 sec.). E1 L L΄΄ C1 Parallel connection with 1-channel motion detectors (max. 8 parallel) L N E1 N L L΄΄ C1 N L L΄΄ C1 Standard mode with 1-channel motion detector (f.ex. stairs) L N T2 L 30 sek. 10 min. 4 3 N L L΄΄ C1 MAN 6132 – 270812–4 T1 E1 N
© Copyright 2026 Paperzz