GE Sensing The Modus Model DA is a controller designed for the monitoring of low differential pressures. It combines in one enclosure a low pressure transducer, a digital display, and up to two alarms (see figure 1). panel. Figure 2 shows a typical deadband diagram for an alarm energizing on falling pressure. When the momentary push button is pressed, the reading on the display is the position of the midpoint of the deadband. A 4 to 20 mA output is also available as an option. The Modus Model DA controller is typically used for the monitoring of clean room pressures, duct static and velocity pressures; as well as filter differential, draft, fume hood, and other low pressure applications. When the potentiometer is turned all the way counterclockwise, the lowest reading appearing on the display is half the deadband. Barb fittings and pluggable terminals with screw clamps are provided at the rear for quick and simple field connections. The pressure sensing element is a differential capacitance cell for pressure measurements ranging from 0.1 in to 5.0 in (2.5 mm to 127 mm) of water (25 Pa to 1.0 kPa), or a piezoresistive (silicon) sensor for pressures from 5 in (127 mm) of water to 30 PSI (1.0 kPa to 200 kPa). The display section has three 1/2 digits with bright, easy to read LEDs. The display is factory-calibrated to read in engineering units. The alarm section is offered with one or two alarms. Each alarm may be ordered with a relay or transistor output. Each setpoint is displayed by pressing a button on the front panel and its setting is changed by means of a multiturn potentiometer also accessible on the front Modus Model DA General Eastern Low Differential Pressure Alarm Controller Modus Model DA is a General Eastern product. General Eastern has joined other GE high-technology sensing businesses under a new name—GE Industrial, Sensing. g Pressure Hi Lo Power VAC, In Setpoints 1 2 Outputs 1 Pressure transducer Alarms Power supply 1.8.8.8 display 2 Figure 1_Block Diagram GE Sensing Model DA Specifications 3.93 in (89.6 mm) Screw clamp 2 places On *=Deadband Output state 0.30 in (75 mm) 1* 2 1* 2 Minimum setpoint Setpoint 1* 2 3.78 in (96 mm) Off 0 Pressure Top View Figure 2_Deadband Diagram Modus General Accuracy of Reading Standard ±1% of span one digit (including non-linearity and hysteresis) 3 2 1 Setpoint Inches of water Front View Alarm receptacle (plug not shown) 1 2 3 4 5 6 7 8 9 Alar m1 Setpoint Accuracy ±0.2% of span one digit (including repeatability) HI J3 Alar m2 A B 0.19 in (4.75 mm) OD pressure fittings LO J1 AC Power AC power receptacle (plug not shown) Rear View 5.72 in (145 mm) Power Requirements 21 to 32 VAC, 50/60 Hz, 105 to 135 VAC, 50/60 Hz or 210 to 265 VAC, 50/60 Hz Electrical Connections Non-interchangeable power and alarm plugs with #4-40 screw clamps; wire range is 14 to 22 AWG 1.89 in (48 mm) Power Consumption 2.5 VA 5.28 in (134 mm) 0.25 in (6 mm) maximum panel thickness 1.67 in (42.5 mm) Side View 3.62 in (92 mm)/ 3.65 in (92.8 mm) Plug with #4-40 screw clamp wire range: 14-22 AWG 177 in (45 mm)/ 1.8 in (45.6 mm) Warmup Time Five minutes to rated accuracy Panel Cutout (Per DIN standard 43700) Modus Model DA dimensions GE Sensing Model DA Specifications Pressure Transmitter Measures differential, gage pressure or vacuum Medium Air or inert gases Standard Pressure Ranges See table A for English units and metric units Maximum Safe Momentary Overpressure See table A Zero and Span Adjustments 15-turn potentiometers accessible behind red front filter Port Connections 3/16 in (4.75 mm) diameter suitable for 1/8 in or 5/32 in ID Tygon™ or polyurethane tubing; 1/4 in OD polyethylene tubing. Air filter at both ports Display Display Three 1/2 digits, seven segments, orange-red LEDs, 0.56 in (14.2 mm) high, decimal point factory-programmable to four positions (1.8.8.8) Conversion Rate Three readings/second Polarity Automatic, no positive sign, “–” negative sign Overrange Indication Beyond 1999 display shows “1” Zero and Span Adjustments 15-turn potentiometers accessible behind red front filter Alarms Number of Alarms One or two alarms Setpoint Adjustment 15-turn potentiometer accessible through hole in front filter Setpoint Display By pressing momentary push button in front of controller Deadband Factory set at 5% of range to prevent output chatter in most applications Output Each alarm is available with either: A) • SPDT (One form C) electromechanical relay; contacts • rated at 5 A 30 VDC 120 VAC, or 4 A at 240 VAC resistive • Contact material is gold overlay • Isolation between contacts and coil is 2000 VAC one minute B) • Transistor (NPN with open collector) rated at: 40 VDC off-state voltage • 120 mA DC on-state current when using an external power supply • 40 mA per alarm when using the internal 5 VDC supply (consult factory for higher currents) • 0.4 V saturation voltage at 100 mA • Internal diode to absorb transients when the internal 5 VDC supply is connected to inductive loads GE Sensing Model DA Specifications Environmental Operating Temperature 32°F to 125°F (0°C to 52°C) Storage Temperature -40°F to 185°F (-40°C to 85°C) Relative Humidity 0 to 90% non-condensing Effect of Temperature ±0.03%/°F reading (±0.05%/°C reading), ±0.005%/°F (±0.01%/°C) setpoint Physical Dimensions 1/8 DIN case (see drawing) Case Material Glass-reinforced NORYL® rated UL94V-1 Weight 1.0 lb (454 g) Offset If the controller must operate when a reversal of pressure occurs, then an offset must be specified. To order a controller with offset zero, estimate the maximum positive pressure excursion needed and select the appropriate pressure range from Table A. Then estimate the maximum negative pressure excursion. If it is about equal to the positive excursion, specify “B” offset. If the negative excursion is less than half of the positive excursion, specify an “A” offset. Alarm Outputs • R Electromechanical relay • T Transistor, NPN with open collector (specify if external power supply is used) The above alarms can be configured at the factory to energize on rising or falling pressure. To specify the logic, add the following letter after the alarm type: • R Energizing on rising pressure • F Energizing on falling pressure For example: Alarm one is selected with a transistor energized on falling pressure, the ordering code is “TF”. Alarm two is a relay energized on rising pressure, the code would be “TR”. GE Sensing Model DA Specifications Wiring Diagrams Standard Pressure Ranges Pressure Range 0 to 0.1 inH20 0 to 0.2 inH20 0 to 0.5 inH20 0 to 1.0 inH20 0 to 2.0 inH20 0 to 5.0 inH20 0 to 10.0 inH20 0 to 20.0 inH20 0 to 1 psi 0 to 2 psi 0 to 3 psi 0 to 5 psi 0 to 15 psi 0 to 30 psi Displayed Units(2) .100 .200 .500 1.000 1.999 5.00 10.00 19.99 1.000 1.999 3.00 5.00 15.00 30.0 Resolution 0.001 in 0.001 in 0.001 in 0.001 in 0.001 in 0.01 in 0.01 in 0.01 in 0.001 in psi 0.001 in psi 0.01 in psi 0.01 in psi 0.01 in psi 0.1 in psi Maximum Overpressure 5 in 5 in 5 in 20 in 20 in 5 psi 5 psi 5 psi 15 psi 15 psi 15 psi 15 psi 30 psi 60 psi **E Contact factory for other pressure ranges displayed units and resolution. Metric Units, Millimeters of Water Pressure Code(1) 01M 02M 04M 05M 06M 08M 09M 11M 13M 14M 15M 16M 17M Pressure Code(1) 01P 02P 04P 05P 06P 08P 09P 11P 13P 14P 15P 16P 17P Pressure Range 0 to 25 Pa 0 to 50 Pa 0 to 100 Pa 0 to 250 Pa 0 to 500 Pa 0 to 1.0 kPa 0 to 2.5 kPa 0 to 5.0 kPa 0 to 10 kPa 0 to 25 kPa 0 to 50 kPa 0 to 100 kPa 0 to 200 kPa Displayed Units(2) 250 50.0 100.0 250 500 1.000 2.50 5.00 10.00 25.0 50.0 100.0 199.9 Resolution 0.1 Pa 0.1 Pa 0.1 Pa 1 Pa 1 Pa 1 Pa 10 Pa 10 Pa 10 Pa 100 Pa 100 Pa 100 Pa 100 Pa Maximum Overpressure 1.25 kPa 1.25 kPa 1.25 kPa 5.0 kPa 5.0 kPa 35 kPa 35 kPa 35 kPa 100 kPa 100 kPa 100 kPa 200 kPa 400 kPa **P Contact factory for other pressure ranges displayed units and resolution. English Units Pressure Code(1) 01E 02E 04E 05E 06E 08E 09E 11E 15E 16E 17E 18E 19E 20E Metric Units, Pascals Pressure Range 0 to 2.50 mmH20 0 to 5.00 0 to 10.0 0 to 25.0 0 to 50.0 0 to 100 0 to 250 0 to 500 0 to 1.00 m 0 to 2.50 m 0 to 5.00 m 0 to 10.0 m 0 to 20.0 m Displayed Units(2) 2.50 5.00 10.00 25.0 50.0 100.0 250 500 1.000 2.50 5.00 10.00 19.99 Resolution 0.01 mm 0.01 mm 0.01 mm 0.1 mm 0.1 mm 0.1 mm 1.0 mm 1.0 mm .001 m .01 m .01 m .01 m .01 m **M Contact factory for other pressure ranges displayed units and resolution. Maximum Overpressure 125 mm 125 mm 125 mm 500 mm 500 mm 3.5 m 3.5 m 3.5 m 10 m 10 m 10 m 20 m 40 m (1) Use this code when ordering. (2) This column shows the number of digits that are displayed and the position of the decimal point. J3, Connector Controller C NO NC 1 (4) Terminals 2 (5) 3 (6) Relay Figure 3_Relay output Shows the internal wiring of the electromechanical relay. This type of output will switch small loads such as pilot lights or audible alarms. Also, the gold contacts offer a reliable output when a contact closure must be sensed and the current is very low. J3, Connector Controller 1 (4) Terminals Transistor 2 (5) +5 VDC Diode 3 (6) Solid-state relay Figure 4_Transistor output, internal power supply A wiring diagram of the transistor output connected to a solid-state relay. The input voltage range of the relay is 3 to 32 VDC. Power is supplied by the internal 5 VDC supply of the controller. If an inductive load is connected, the internal diode will protect the transistor against transients. GE Sensing Model DA Specifications Controller J3, Connector Diode* 1 (4) Terminals Transistor 2 (5) +5 VDC Load Power supply 40 VDC maximum 3 (6) *Diode required with inductive loads. _ Figure 5 Transistor output, external power supply Shows the transistor controlling a load powered by an external 12 or 24 VDC supply. An external diode or other means of limiting transients to 40 Volts must be added if the load is inductive. The current must not exceed 120 mA. Ordering Information Record selected option in blank indicated at bottom of form. DA Code 1 2 3 Power Supply 120 VAC 240 VAC 24 VAC Code Input Pressure X See Standard Pressure Range Tables Code Offset 0 No offset A 1/4 offset B 1/2 offset Code Alarm Output R Electro mechanical T Transistor Code Energize (E) F Falling pressure R Rising pressure Code Option 420 4 to 20 mA output DA - ___ - ___ - ___ - ___ - ___ - ___ Typical model number GE Sensing GE Sensing g ©2006 GE. All rights reserved. 920-295A All specifications are subject to change for product improvement without notice. GE® is a registered trademark of General Electric Co. Other company or product names mentioned in this document may be trademarks or registered trademarks of their respective companies, which are not affiliated with GE. www.gesensing.com
© Copyright 2026 Paperzz