Legrand Surface mounting

Surface-mounting floor units,
floor service outlet boxes, access units
Metal and plastic backboxes
for concrete floor
0 896 44
0 317 48
0 896 34
0 893 07
0 896 49
0 896 30
Technical characteristics see e-catalogue
Pack
5
5
10
Cat.Nos
Surface-mounting floor sockets to be
equipped
Empty electrical wiring accessories to be equipped
with Mosaic screw connection sockets
Equipped with pivoting wiring supports for easy
installation of sockets
Can be combined with over floor trunking
Cat.No 0 328 00
Can be illuminated with LED Cat.No 0 899 06
0 317 48 2 x 4 modules
0 317 49 3 x 4 modules
0 899 06 LED to be wired, 230 V
High luminescence orange neon
Technical characteristics see e-catalogue
Cat.Nos
Adjustable metal backbox for concrete floor
1
0 896 34
5
5
0 896 35
0 896 36
5
0 896 37
5
0 896 38
Universal backbox
For junction of LV and ELV cabling and/or installation
of floor boxes
Height adjustable from 56 mm to 140 mm using
4 screws located in the box corners and a tool
adapting to electric drill or screwdriver
Bendable side walls for joining with different sizes of
floor ducts
Supplied with worksite protection cover to be
replaced by blanking cover plate or mounting cover
plate
Universal metal in-screed backbox
Cover plates
Thickness 3 mm
Blanking cover plates for simple junction
Adaptor plate for floor boxes
12 modules, or floor boxes of reduced height
10 modules
Adaptor plate for floor boxes
18 modules
Adaptor plate for floor boxes
24 modules, or floor boxes of reduced height
16 modules
Pack
Floor service outlet boxes - 3 modules
1
1
Access units for raised or concrete floor (minimum
height 80 mm)
To be equipped with: 1 Mosaic socket outlet 2P+E
2 modules and 1 Mosaic RJ 45 - 1 module or
1 Arteor socket outlet 2P+E and 1 Arteor RJ 45
1 module
Grey RAL 7031
0 896 44 Floor service outlet box - 3 modules
0 896 49 Flush-mounting box for concrete for Cat.No 0 896 44
Small aluminium access grommet
1
Body - cast aluminium
Main jaw - injection mouled plastic Nylon 66
Inner jaws - closed cell Neoprene
Recommended hole cut-out size: 127 mm diameter
Will fit floor tile thickness range of 25 to 55 mm
Can form the base of a cable management products
such as power posts and poles
Standard depth: 60 mm
0 893 07 Access grommet
IP 20 - IK 08
Auto-adjustable plastic backboxes for
concrete floor
1
1
1
Access units
1
1
0 896 90
0 896 91
1
1
0 896 94
0 896 95
Access units for raised or concrete floor (minimum
height 90 mm)
Supplied with stainless steel cover or cover for
carpet
Grey RAL 7031
Small dimensions
With cover for carpet
With stainless steel cover
Large dimensions
With cover for carpet
With stainless steel cover
For integration of floor boxes in in-screed floor
installations
Power supply by flexible conduits Ø16, 20 and 25 mm
Supplied with polystyrene for easy installation
0 896 30 For 12 modules floor boxes or 10
modules reduced height floor boxes
0 896 31 For 18 modules floor boxes
0 896 32 For 24 modules floor boxes or 16
modules reduced height floor boxes
Backboxes for shallow concrete floor and
insulation boxes for raised floor
1
1
For integration of 50 mm "reduced height" floor boxes
Cat.No 0 880 70 (see opposite) in raised or screed
floor installations
Power supply by flexible conduits Ø16, 20 and 25 mm
or floor trunking 28 mm height
0 880 73 Backbox for shallow concrete floor
0 880 71 Insulation box for raised floors
PVC floor duct,
please consult us
1
Adjustable height floor boxes
to be equipped
0 896 05
Reduced height floor boxes
to be equipped
0 896 26
0 896 11 equipped
with Mosaic sockets
Technical characteristics see e-catalogue
Pack
Cat.Nos
1
0 896 05
1
0 896 06
1
0 896 07
1
0 896 10
1
0 896 11
1
0 896 12
1
0 896 15
1
0 896 16
1
0 896 17
75-105 mm adjustable height floor boxes
For raised or screed floor between 75 and 105 mm
Conform to standard EN 60-670 and EN 50085-2-2
Workstation connection for raised for screed floor,
using plastic or metal backbox (see opposite)
Supplied with reversible stainless steel cover or cover
for carpet
Horizontal wiring device positioning:
- height adjustable from 75 to 105 mm
- ensure perfect cable separation
- takes 2 flexible conduits Ø20 mm
- shifted from one another for optimal connection for
all sockets
- take marking labels
Easy opening cover with rings and holding in open
position during connection
To be equipped with Mosaic or Arteor wiring
accessories
12 modules
With stainless steel cover
Grey RAL 7031
With cover for carpet
Grey RAL 7031
With cover for carpet
Beige RAL 1019
18 modules
With stainless steel cover
Grey RAL 7031
With cover for carpet
Grey RAL 7031
With cover for carpet
Beige RAL 1019
24 modules
With stainless steel cover
Grey RAL 7031
With cover for carpet
Grey RAL 7031
With cover for carpet
Beige RAL 1019
Pack
Cat.Nos
65 mm "reduced height" floor boxes
1
1
1
For raised or screed floor ≥ 65 mm
Conform to standard EN 60-670 and EN 50085-2-2
Workstation connection for raised or concrete floor,
using plastic or metal backbox (see opposite)
Supplied with reversible stainless steel cover or cover
for carpet or parquet
Vertical wiring device positioning:
- supplied with blanking plates requiring sufficient
space between the sockets if angled plugs are used
- takes marking labels
- ensures perfect cable separation
Easy opening cover by rings and holding in open
position during connection
To be equipped with Mosaic or Arteor wiring
accessories
10 modules
For installing 4 x 2 modules Mosaic and
2 x 1 module Mosaic
0 896 20 With stainless steel cover, grey RAL 7031
0 896 21 With cover for carpet, grey RAL 7031
0 896 22 With cover for carpet, beige RAL 1019
1
1
1
16 modules
For installing 8 x 2 modules Mosaic
0 896 25 With stainless steel cover, grey RAL 7031
0 896 26 With cover for carpet, grey RAL 7031
0 896 27 With cover for carpet, beige RAL 1019
50 mm "reduced height" floor boxes
1
1
16 modules
0 880 70 For raised or screed floor betwen 50 and 70 mm
Workstation connection for raised or concrete floors
To be used with backbox Cat.No 0 880 73
(in concrete floors) or with insulation box
Cat.No 0 880 71 (in raised floors) (p. 772)
Supplied with cover for carpet
Vertical wiring device positioning
Ensures perfect cable separation
Easy opening cover by handle
To be equipped with Mosaic or Arteor wiring
accessories
With cover for carpet, grey RAL 7031
Can be equipped with stainless steel finishing plate
Cat.No 0 880 72
Stainless steel finishing plate
0 880 72 For 50 mm reduced height floor box
Cat.No 0 880 70
2
Floor boxes for carpet
6 896 30 equipped with
British Standard sockets
and wiring devices
(p. 369 to 378)
6 896 39
Rigid cable exits
6 896 60
6 896 31 equipped with
British Standard sockets
and wiring devices
(p. 369 to 378)
6 896 34
Flexible cable exits
6 896 73
6 896 78
Technical characteristics see e-catalogue
Conform to IEC 60670-23 and to BS EN 50 085-2.2
Compatible with either raised access floor trunking system and screed floor system
Pack
Cat.Nos
Lid and trims for carpet
5
5
To be equipped with Arteor wiring accessories
Supplied with flexible or rigid cable exits
3-compartment floor boxes
To be fllled on either
- modular backbox for raised floors Cat.No 6 896 39
- screed floor backbox Cat.No 6 896 34
6 896 30 Grey cover RAL 7031 with rigid cable exits
6 896 31 Grey cover RAL 7031 with flexible cable exits
5
5
4-compartment floor boxes
To be fllled on either
- modular backbox for raised floors Cat.No 6 896 49
- screed floor backbox Cat.No 6 896 45
6 896 40 Grey cover RAL 1019 with rigid cable exits
6 896 41 Grey cover RAL 1019 with flexible cable exits
Modular backbox for raised floors
3
1
Adjustable height between 86 to 107 mm
To be fitted with lid and trims for carpet and support
plates for Arteor Wiring accessories (p. 385)
Backboxes are connected to the raised floor
trunking system with flexible conduits
One complete assembly consists of: support frame
+ modules + lid and trim
Support frame
To be equipped with modules below
6 896 39 3 compartments (264 x 264 mm)
1
6 896 49 4 compartments (264 x 341 mm)
4
6 896 60 Single module for 77 mm plates
Module
Pack
Cat.Nos
Screed floor backboxes
1
To be fitted with lid and trim for carpet and support
plates for Arteor mechanisms
Accept PVC and metal screed floor ducting and
conduits Ø20 mm and Ø25 mm
Auto-adjustable to screed height 65 up to 90 mm
For ducting up to 225 mm
6 896 34 3 compartments
1
For ducting up to 300 mm
6 896 45 4 compartments
Support plates for Arteor mechanism
12
12
12
6 896 73
6 896 74
6 896 77
4
6 896 78
Support plates for integration of Arteor mechanisms
in floor boxes
77 mm width plate
Flat support plates
For 4 modules (2 x 2 modules)
For 6 modules (3 x 2 modules)
For 6 modules (2 x 3 modules)
Waved support plates
For 4 modules (2 x 2 modules)
Floor boxes for tiles/marble
6 896 56 + 0 896 04
Steel & polycarbonate floor box
6 896 51 + 0 896 04
6 896 56 equipped
with Arteor mechanisms
(p. 369 to 378)
6 896 51 equipped
with Arteor mechanisms
(p. 369 to 378)
CFB3EC
Technical characteristics see e-catalogue
Conforms to IEC 60670-23 and to BS EN 50 085-2.2
Compatible with screed floor system
Pack
Cat.Nos
Lid and trim for tiles/marble
To be installed in backbox Cat.No 0 896 04 for
screed floor system
To be equipped with support plates for Arteor
mechanisms (p. 385)
1
1
1
1
1
Pack
Cat.Nos
1
CFB3EC
1
CFB6MOD
1
CFBBLANK
Single cable outlet stainless steel lid and trim
6 896 56 Edge trim for tile 8 to 15 mm thickness
Single cable outlet powder coated lid and trim
6 896 55 Edge trim for tile 8 to 15 mm thickness
Grey RAL 7031
Double cable outlet stainless steel lid and trim
6 896 51 Edge trim for tile 8 to 15 mm thickness
6 896 52 Edge trim for tile 15 to 12 mm thickness
3-compartment floor box
for South Africa
Floor box
Recommended hole cut out size:
305 x 225 mm
Standard depth: 75 mm
Universal knockouts (20/25 mm) to each
compartment
Manufactured from pre-galvanised steel
and polycarbonate/ABS
Supplied with back box
Support plate for Arteor mechanism
For 6 modules
Blank plate
For unused space
Specific backbox
0 896 04 For installation of floor boxes
Cat.Nos 6 896 51/52/55/56 for screed
floor system
4
Heavy duty in-screed floor box
Heavy duty in-screed floor box
for concrete floors
n Metal in-screed floor box, installation principle
When used as junction box
Junction box with plain cover Cat.No 0 896 85
0 896 34 + 0 896 83 + 0 896 85
0 896 34 + 0 896 83 + 0 896 86 + 0 896 87
Junction box
with plain cover
Cat.No 0 896 85
Set for normal
load
Cat.No 0 896 83
or set for heavy
load
Cat.No 0 896 84
0 896 34 + 0 896 83 + 0 896 88
Metal backbox
Cat.No 0 896 34
For highly frequented areas, requiring important mechanical resistance
and/or washing down
Conform to standard EN 60-670 and EN 50 085-2-2
Pack
1
Cat.Nos
Metal in-screed floor box
0 896 34 Universal metal in-screed backbox
Junction or connection point for
concrete floor according to type of
cover associated
For junction of LV and ELV cabling and/or installation
of floor boxes
Height adjustable from 105 mm to 140 mm using
4 inserts located in the box corners and a tool
adapting to electric drill or screwdriver
Bendable side walls for assembling with different
sizes of floor ducts
Supplied with worksite protection cover to be
replaced by blanking cover plate or mounting cover
plate
Allowing floor covering infill between 6 and 24 mm
When used as floor box for wiring accessories
Floor box with central cable Cat.No 0 896 86
Cable exit
Cat.No 0 896 87
Accessories for metal in-screed floor box
1
0 896 83 Normal load support
Up to 8 KN load with deflection < 6 mm
1
0 896 84 Heavy load support
Up to 20 KN load with deflection < 3 mm
6
0 896 39 Set of 2 conduit adaptors for metal cavity
floor box Cat.No 0 896 34
- Floor box with central
cable Cat.No 0 896 86
- Wiring accessories
support
- Wiring accessories
frames
Plates for metal in-screed floor boxes
5
1
0 896 85
1
0 896 86
1
0 896 87
1
0 896 88
For metal in-screed floor box Cat.No 0 896 34
Use support Cat.No 0 896 83 or 0 896 84
All types of floors
IP 66 plain cover (cover closed)
Access trap for junction, no cable exit
Marbled and tiled floors
IP 66 plate (cover closed and plugs not
connected) with central cable exit
To receive 24 mosaic modules
Supplied with all necessary wiring accessories
supports
Accessory for plate with central cable exit
Cable exit accessory for IP 66 cover plate
Cat.No 0 896 86
Wooden floors
IP 30 plate with 2 lateral cable exits
To receive 24 mosaic modules
Supplied with all necessary wiring accessories
supports
Set for normal load
Cat.No 0 896 83 or
Set for heavy load
Cat.No 0 896 84
Metal backbox
Cat.No 0 896 34
Pop-up type flush-mounting boxes
for workstation & meeting room table applications
0 540 13
0 540 18
0 540 23
0 540 45
0 540 00
0 540 06
0 540 47
Technical characteristics p. 778
Can be installed in concrete or raised access floors or integrated directly into the furniture (desks, meeting room tables, etc)
Conform to IEC 60670-1, IEC 60670-23 et IEC 60884-1
Pack
Cat.Nos
1
1
1
0 540 10
0 540 15
0 540 20
1
1
1
0 540 12
0 540 17
0 540 22
1
1
1
1
1
0 540 11
0 540 16
0 540 21
0 540 26
0 540 31
1
1
1
1
1
0 540 13
0 540 18
0 540 23
0 540 28
0 540 33
Pop-up boxes to be equipped
Slim design for perfect integration into the floor or
office furniture
Soft opening for enhanced comfort and safety
Equipped with "push and slide" locking system to
avoid accidental opening by feet
To be equipped with Mosaic or Arteor socket outlets
For installation use the flush-mounting boxes for
concrete floors or the kits for raised access floors or
table top (see below)
3 modules
Matt Aluminium finsih
Brushed Brass
Brushed Stainless Steel finish
6 (2 x 3) modules
Matt Aluminium finsih
Brushed Brass
Brushed Stainless Steel finish
4 modules
Matt Aluminium finsih
Brushed Brass
Brushed Stainless Steel finish
Matt Black
Glossy White
8 (2 x 4) modules
Matt Aluminium finsih
Brushed Brass
Brushed Stainless Steel finish
Matt Black
Glossy White
Pack
1
1
1
1
0 540 00
0 540 02
0 540 01
0 540 03
1
10
6 503 90
6 503 31
1
1
1
1
0 540 05
0 540 07
0 540 06
0 540 08
Flush-mounting boxes for installation in
concrete floors
For installation of pop-up floor boxes in concrete floors
Equipped with knockouts for Φ 20 and Φ 25 mm
conduits
Metal flush-mounting boxes
3 modules
6 (2 x 3) modules
4 modules
8 (2 x 4) modules
Plastic flush-mounting boxes
3 modules
6 modules
Retractable kits
1
1
Composition:
- retractable cord
- Mosaic cover plate
- fixing accessory
0 540 34 RJ 45 cat. 6 UTP retractable kit. 1 module
0 540 36 USB/micro-USB retractable kit. 1 module
Equipped pop-up boxes
1
1
Slim design for perfect integration into the floor or
office furniture
Soft opening for enhanced comfort and safety
Equipped with "push and slide" locking system to
avoid accidental opening by feet
Supplied with installation kits for raised access floors
or table top
With power & data sockets - 4 modules
Pre-wired and equipped with:
- 1 x 2P+E socket - German standard
- 2 x RJ 45 data sockets Cat. 6 UTP
- 2 m cord with 2P+E plug
- 3 m RJ 45 cord with RJ 45 Cat. 6 UTP plug
0 540 44
Glossy White
0 540 45
Brushed Stainless Steel finish
1
1
With power, data & audio-video sockets
8 (2 x 4) modules
Pre-wired and equipped with
- 2 x 2P+E socket - German standard
- 2 x RJ 45 data sockets Cat. 6 UTP
- 1 HD 15 connector + 3.5 mm jack
- 2 m cord with 2P+E plug
- 3 m RJ 45 cord with RJ 45 Cat. 6 UTP plug
- 0.1 m female VGA cord
- 0.1 m female jack 3.5 mm cord
0 540 46
Glossy White
0 540 47
Brushed Stainless Steel finish
Installation kits for raised access floors or
table top
Include an empty receptacle and fixing brackets for
raised access floor tiles or table tops
Equipped with cable retainer for power cables, to
ensure increased safety of the installation
Compatible with:
- Cat. 6 data cabling
- audio/video cabling
3 modules
6 (2 x 3) modules
4 modules
8 (2 x 4) modules
Cat.Nos
6
Pop-up type flush-mounting boxes
technical characteristics
■ Technical characteristics
■ Dimensions
Classification of pop-up flush-mounting boxes according to
NFC 61-314 / EN 60670-1 / EN 60670-23
Earthing system:
R < 0.05 Ohms
Protection against mechanical impact: IK 07
Degree of protection: IP 30 cover open
IP 40 cover closed
Resistance to vertical load applied through small surface area:
1500 N cover open
3000 N cover closed
Rated voltage:
U 500 V - R > 5 MOhms
Electric strength:
2000 V
Installation on the floor: to be installed on floor subjected to a dry
treatment
Cover
Material
Halogen free, fire proofed and no propagator of the flame
Corrosion resistant and to temperature changes
Finishes
Material
Brass
Brass material
Aluminium
Aluminium material
Stainless Steel
Zamak nickel coating
Black
Aluminium material with black painting
White
Aluminium material with white painting
A
B
Pop-up size
A (mm)
B (mm)
3 modules
120
120
4 modules
120
142.5
6 modules
120
230
8 modules
120
275
C
Empty pop-up
D
A
High/low current compatibility
B
Floor type
High current
Low current
Concrete
Yes
No
Pop-up size
A (mm)
B (mm)
C (mm)
Technical floor
Yes
Cat. 6 compatible
3 modules
79.8
92
57
77.5
Furniture
Yes
Cat. 6 compatible
4 modules
102.3
114.5
57
77.5
■ Installation
D (mm)
6 modules
189.8
202
57
77.5
8 modules
231.6
247
57
77.5
Pop-up with installation kit for desk or technical floor
C
Desk or technical floor
A
A
B
B
A(1) (mm)
B(1) (mm)
A (mm)
B (mm)
C (mm)
3 modules
108
108
3 modules
79.8
92
74.8
96.1
4 modules
108
131
4 modules
102.3
114.5
74.8
96.1
6 modules
108
218
6 modules
189.8
202
74.8
96.1
263
8 modules
231.6
247
74.8
96.1
Pop-up size
8 modules
108
Pop-up size
D
D (mm)
1: +/- 1 mm
Concrete floors (fixing centres)
A
Pop-up size
A (mm)
3 modules
84
4 modules
106.5
6 modules
194
8 modules
239
www.klinkmann.ee
778
Klinkmann Eesti AS
Mehaanika 2b, 10616 Tallin, Estonia
Tel: + 372 6 684 500, Faks: + 372 6 684 501
E-post: [email protected]