Passive House Institute Dr. Wolfgang Feist 64283 Darmstadt GERMANY Certified Passive House Component for cool, temperate climate, valid until 31.12.2015 Category: Manufacturer: Product name: Attic staircase Wellhöfer Treppen GmbH & Co.KG 97084 Würzburg, GERMANY Passive House Attic Stairs This certificate was awarded based on the following criteria: Representation of the Passive House Attic Stairs A given component size of 1.40 m by 0.70 m results in: UD = 0.77 W/(m²K) ≤ 1.00 W/(m²K) Isothermal map of the Passive House Attic Stairs Taking the installation situations into account, the component meets the following criterion. UD,installed ≤ 1.10 W/(m²K) ≥ 0.70 Functional requirements of hygiene: fRsi = 0,25 m²K/W Isothermal map installation in concrete ceiling Following thermal bridge coefficients Ψ [W/(mK)] have been determined: Thermal bridge coefficient Ψ [W/(mK)] UD,installed [W/(m²K)] Wooden- beam ceiling Concreteceiling - 0.04 0.08 - 0.94 1.10 - Description Chipboard (λ = 0.136 W/(mK)) with insulation panel (λ = 0.039 W/(mK)) with two EPDM sealings between frame and insulation panel. A sealing tape is installed in between the hatch and the ceiling. An insulation filling (λ = 0.04 W/(mK)) for reducing the thermal bridge of the installation to the connection of the hatch is inserted. Please ask the manufacturer for a detailed report containing all calculations and results. www.passivehouse.com Pilotcertificate Isothermal map installation in woodenbeam ceiling