Aviation upgrade - Isoil Impianti SpA

VegaT
Aviation upgrade
Data sheet: DS/VE/0022/EN Ed.November 2015
The Aviation market is a growing and
successful market for Isoil Impianti. This is to due
to our specific product range, development,
and the new dedicated sales and support
network.
VegaT is one of the dedicated products
appreciate by many customers for its full
feature package and superior performance.
Due to market requirements, we have added
additional features.
Keyboard access control
Unlike our competitors of electronic registers, VegaT has always a full keyboard available, this
makes life easy for operators, especially those who need to insert data for maintenance,
installation or calibration meter data.
However we receive some feedback from end users, especially those who used MasterLoad
register previously, that too many button can create a perception that Vega T is not user
friendly.
The standard version of VegaT allaws a password protection to access the menu, so in any
event the operator cannot change anything without permission. This feature is basically to
keep the focus strictly on the loading operation.
Regarding the number of buttons, we have designed two solutions, both available now for
new purchases. Additionally existing Vega T can be upgraded
Up to four LFD6 display per VegaT with flow rate and total
LFD6 is a product that you can be found on many aviation trucks, sometimes even
interfaced with competitors equipment.
Based on this good experience, our customers are requiring to have more than delivered
volume displayed. We are now receiving requests for additions like ROF to be displayed. This
is to control the refuelling operations from other locations other than local to Vega T.
This feature is available now for new purchases. For existing installed equipment these
can be upgraded.
ISOIL IMPIANTI S.p.A.- 24061 Albano S. Alessandro (BG) - Italy
tel: +39.02.91988.5 fax: +39.02.66012457
web:www.isoilmeter.come-mail: [email protected]
DS/VE/0022/EN - 11/2015
Pag. 1/4
Keyboard Mask
In many hydrant dispenser and
refuelling operation, no preset
function is required neither any data
input. The only action required is to
clear and print the data at the end
of the dispatch.
For such users a heavy duty
anodised aluminium mask is now
available. This permits the use of
only two pushbuttons
necessary to clear the register and confirm the operation, receiving the
print out and to reset LFD6 additional displays.
The mask includes 4 non-loose mounting screws, special
adapter frame to be installed in any VegaT.
This version is available for new purchases additionally a
proper kit including the new software, that uses only two push
at the end of the operation, is available to upgrade existing
units.
Lock Menu by switch
An alternative solution to the mask, for who needs full
access to the keyboard but needs to have a second level
of access control over the password, is the possibility to lock
the Menu pushbutton by an external switch.
During normal operation, if you push the menu it opens a
screen asking the password. In this way the system is
protected, but with this new function, the menu button is
activated only if an authorized person unlock it by using the
external locked switch.
It can be a standard switch since VegaT allows an intrinsically safe
interlock inputs to avoid costly armoured explosion proof switches. The
switch can be with a key lock.
The new functionality is actually included into our standard software
on VegaT for aviation and a software kit is available to upgrade
previous versions.
VegaT supplied before October 2015 need to install this new software.
Contact us for offer.
External locked switch
ISOIL IMPIANTI S.p.A.- 24061 Albano S. Alessandro (BG) - Italy
tel: +39.02.91988.5 fax: +39.02.66012457
web:www.isoilmeter.come-mail: [email protected]
DS/VE/0022/EN - 11/2015
Pag. 2/4
Up to four LFD6 with dual data
Now there is a new software VegaT that
allow it to be interfaced with can be
interfaced with up to four LFD6 that can
display two different data, including
delivered volume or instantaneous flow rate.
Specifically an instantaneous flow rate is
required to see how fast the fuelling
operation are going and if all the
equipment, including filtration, are reducing
the flow rate.
Thanks to the automatic adjustment of the LED lights, the LFD6
can be also visible from long distance like a platform location.
The new software permit to have up to four LFD6 with assigned,
for each one, the data1 or data2 display. The switch from
data1 to data2 happen push an external button or toggle a
switch connected to the intrinsically safe input VegaT.
The input can be a switch or a pushbutton. If the second one is
chosen, a time in seconds can be inserted about the permanence of
the second data when the button is pressed.
The data can be chosen from the below table:


Meter one or meter two (on a VegaT for two meters)
Gross volume

Gross standard volume (on a temperature compensated version)

Mass (based on inputted density)


Preset in decreasing
Instantaneous flowrate
The communication link is by means of a native RS485 serial port communication.
Here below the two main screen where LFD6 readout is set up
ISOIL IMPIANTI S.p.A.- 24061 Albano S. Alessandro (BG) - Italy
tel: +39.02.91988.5 fax: +39.02.66012457
web:www.isoilmeter.come-mail: [email protected]
DS/VE/0022/EN - 11/2015
Pag. 3/4
ISOIL IMPIANTI S.p.A.- 24061 Albano S. Alessandro (BG) - Italy
tel: +39.02.91988.5 fax: +39.02.66012457
web:www.isoilmeter.come-mail: [email protected]
DS/VE/0022/EN - 11/2015
Pag. 4/4