VegaT Aviation upgrade Data sheet: DS/VE/0022/EN Ed.November 2015 The Aviation market is a growing and successful market for Isoil Impianti. This is to due to our specific product range, development, and the new dedicated sales and support network. VegaT is one of the dedicated products appreciate by many customers for its full feature package and superior performance. Due to market requirements, we have added additional features. Keyboard access control Unlike our competitors of electronic registers, VegaT has always a full keyboard available, this makes life easy for operators, especially those who need to insert data for maintenance, installation or calibration meter data. However we receive some feedback from end users, especially those who used MasterLoad register previously, that too many button can create a perception that Vega T is not user friendly. The standard version of VegaT allaws a password protection to access the menu, so in any event the operator cannot change anything without permission. This feature is basically to keep the focus strictly on the loading operation. Regarding the number of buttons, we have designed two solutions, both available now for new purchases. Additionally existing Vega T can be upgraded Up to four LFD6 display per VegaT with flow rate and total LFD6 is a product that you can be found on many aviation trucks, sometimes even interfaced with competitors equipment. Based on this good experience, our customers are requiring to have more than delivered volume displayed. We are now receiving requests for additions like ROF to be displayed. This is to control the refuelling operations from other locations other than local to Vega T. This feature is available now for new purchases. For existing installed equipment these can be upgraded. ISOIL IMPIANTI S.p.A.- 24061 Albano S. Alessandro (BG) - Italy tel: +39.02.91988.5 fax: +39.02.66012457 web:www.isoilmeter.come-mail: [email protected] DS/VE/0022/EN - 11/2015 Pag. 1/4 Keyboard Mask In many hydrant dispenser and refuelling operation, no preset function is required neither any data input. The only action required is to clear and print the data at the end of the dispatch. For such users a heavy duty anodised aluminium mask is now available. This permits the use of only two pushbuttons necessary to clear the register and confirm the operation, receiving the print out and to reset LFD6 additional displays. The mask includes 4 non-loose mounting screws, special adapter frame to be installed in any VegaT. This version is available for new purchases additionally a proper kit including the new software, that uses only two push at the end of the operation, is available to upgrade existing units. Lock Menu by switch An alternative solution to the mask, for who needs full access to the keyboard but needs to have a second level of access control over the password, is the possibility to lock the Menu pushbutton by an external switch. During normal operation, if you push the menu it opens a screen asking the password. In this way the system is protected, but with this new function, the menu button is activated only if an authorized person unlock it by using the external locked switch. It can be a standard switch since VegaT allows an intrinsically safe interlock inputs to avoid costly armoured explosion proof switches. The switch can be with a key lock. The new functionality is actually included into our standard software on VegaT for aviation and a software kit is available to upgrade previous versions. VegaT supplied before October 2015 need to install this new software. Contact us for offer. External locked switch ISOIL IMPIANTI S.p.A.- 24061 Albano S. Alessandro (BG) - Italy tel: +39.02.91988.5 fax: +39.02.66012457 web:www.isoilmeter.come-mail: [email protected] DS/VE/0022/EN - 11/2015 Pag. 2/4 Up to four LFD6 with dual data Now there is a new software VegaT that allow it to be interfaced with can be interfaced with up to four LFD6 that can display two different data, including delivered volume or instantaneous flow rate. Specifically an instantaneous flow rate is required to see how fast the fuelling operation are going and if all the equipment, including filtration, are reducing the flow rate. Thanks to the automatic adjustment of the LED lights, the LFD6 can be also visible from long distance like a platform location. The new software permit to have up to four LFD6 with assigned, for each one, the data1 or data2 display. The switch from data1 to data2 happen push an external button or toggle a switch connected to the intrinsically safe input VegaT. The input can be a switch or a pushbutton. If the second one is chosen, a time in seconds can be inserted about the permanence of the second data when the button is pressed. The data can be chosen from the below table: Meter one or meter two (on a VegaT for two meters) Gross volume Gross standard volume (on a temperature compensated version) Mass (based on inputted density) Preset in decreasing Instantaneous flowrate The communication link is by means of a native RS485 serial port communication. Here below the two main screen where LFD6 readout is set up ISOIL IMPIANTI S.p.A.- 24061 Albano S. Alessandro (BG) - Italy tel: +39.02.91988.5 fax: +39.02.66012457 web:www.isoilmeter.come-mail: [email protected] DS/VE/0022/EN - 11/2015 Pag. 3/4 ISOIL IMPIANTI S.p.A.- 24061 Albano S. Alessandro (BG) - Italy tel: +39.02.91988.5 fax: +39.02.66012457 web:www.isoilmeter.come-mail: [email protected] DS/VE/0022/EN - 11/2015 Pag. 4/4
© Copyright 2025 Paperzz