Improved Versatility of the Transcreener® ADP2 Assay: Alternative Fluorescence Detection Modes for All Major Instrument Platforms Tony A. Klink, Thomas K. Zielinski, Matt Staeben, Cori A. Pinchard, Andrew L. Kopp, Tracy J. Worzella, and Robert G. Lowery BellBrook Labs, 5500 Nobel Drive, Suite 250, Madison, WI 53711 Introduction to the Transcreener® ADP2 Assays The Transcreener® ADP2 Assay allows the facile detection and screening of established drug targets including protein and lipid kinases, as well as other ATPases by directly measuring ADP formation. BellBrook Labs extends the robust Transcreener technology from far red fluorescence polarization (FP) to include two other red emission spectrum detection modes including time resolved fluorescence resonance energy transfer (TR-FRET) and fluorescence intensity (FI). The result is compatibility with all major instrument platforms providing the flexibility to move from assay development to high throughput screening using a single assay platform. Validated in multiple microplate well formats, the ADP2 Assays are compatible with most plate readers commonly found both in academic labs and high throughput screening settings. Each Transcreener ADP2 Assay employs BellBrook Labs’ monoclonal ADP2 antibody which has >100-fold selectivity for ADP vs. ATP providing generic ADP detection from at least 0.1 μM to 100 μM ATP at initial velocity conditions (<10% ATP conversion). The single step assay directly detects ADP formed in the enzyme reaction which eliminates false positives seen with technologies that use coupling enzymes prior to detection of ADP. Here, we provide a new EZ protocol which shows a linear relationship between [ATP] and [ADP2 Antibody]. Simply perform the enzyme titration and detect ADP in one step. Furthermore, we compare dose-dependency curves for protein kinase A (PKA) using known inhibitors for each detection mode. An EZ Format Provides a Simple Way to Get Started With Any [ATP] A B 80 60 40 20 0 0 10 20 30 40 50 60 70 80 90 100 C 200 175 y = 1.9x + 7.8 150 125 100 75 50 25 0 100 0 10 20 30 40 50 60 70 80 90 100 y = 0.93x + 0.7 80 ® y = 1.08x + 1 60 40 20 0 2 [ADP HiLyte647 Tracer] nM 100 2 [ADP Antibody] (μg/mL) 120 [ADP Antibody-IRDye QC-1] (μg/mL) Figure 1. The Transcreener ADP2 Assays are generic competitive immunoassays which follow the progress of enzymes that produces ADP. The monoclonal antibody-bound tracer is displaced by ADP, the invariant product of all kinase reactions. With each Transcreener Assay, red tracers minimize interference from fluorescent compounds and light scattering. A) The Transcreener ADP2 FP Assay comprises an AlexaFluor 633 ADP Tracer bound to the ADP2 Antibody. The displaced tracer freely rotates in solution leading to a decrease in fluorescence polarization, relative to bound tracer. Production of ADP is proportional to a decrease in polarization. B) The Transcreener ADP2 TR-FRET Assay comprises ADP HiLyte647™ Tracer bound to ADP2 Antibody-Tb. The displaced tracer no longer participates in FRET leading to a decrease in the 665 to 620 nm emission ratio, relative to bound tracer. Therefore, ADP production creates a concomitant decrease in the FRET dependent emission ratio. The time-gated nature further minimizes interference from fluorescent compounds and light scatter. C) The Transcreener ADP2 FI Assay comprises a quenched ADP Alexa594 Tracer bound to the ADP Antibody conjugated to an IRDye® QC-1 quencher licensed from LI-COR®. The displaced tracer becomes unquenched in solution leading to a positive increase in fluorescence intensity. Therefore, ADP production is proportional to an increase in fluorescence. 0 10 20 30 40 50 60 70 80 90 100110 [ATP] μM [ATP] (µM) Figure 2. The EZ protocol simplifies getting started. The Transcreener Assays allow detection of ADP in the presence of excess ATP (assuming initial velocity enzyme reaction conditions) using an antibody with a finite selectivity for the diphosphate vs. the triphosphate. However, the linear relationship shown here provides an easy method to determine [Detection Reagent] at any [ATP]. A) For FP, the relationship between [ATP] and [ADP2 Antibody] is linear, the quantity of ADP2 Antibody for any [ATP] can be determined using equation of line (y = 1.08x 2 + 1; where x = [ATP] in the enzyme reaction, y = [ADP Antibody] in the ADP Detection Mixture. B) For TR-FRET, the relationship between [ATP] and [ADP HiLyte647™ Tracer] is linear, the quantity of ADP Tracer for any [ATP] can be determined using equation of line (y = 1.9x + 7.8; where x = [ATP] in the enzyme reaction, y = [ADP HiLyte647™ Tracer] in the ADP Detection Mixture. C) For FI, the relationship between [ATP] and [ADP2 Antibody IRDye® QC-1] is linear, the quantity of ADP2 Antibody IRDye® QC-1 for any [ATP] can be determined using equation of line (y = 0.93x + 0.7; where x = [ATP] in the enzyme reaction, y = [ADP2 Antibody IRDye® QC-1] in the ADP Detection Mixture. [ATP] (μ M) ADP2 300 150 Signal Stability 24 hr Deck Stability 1 hr 50 0 0.01 200 Deck Stability 8 hr Deck Stability 24 hr 0.1 1 10 μM ATP 0.1 μM ATP 150 Ratio (665/620 mP Signal Stabilty 1 hr Signal Stability 8 hr 100 250 1 μM ATP 100 10 μM ATP 50 100 uM ATP 1000 μM ATP 0 0.1 1.50 1 10 1.25 1.00 C 0.8 0.6 0.4 0.2 0.0 0.001 50000 Signal Stability 1hr 0.1 μM ATP 1.0 μM ATP 10 μM ATP 100 μM ATP 40000 Signal Stability 8 hr Signal Stability 24 hr Deck Stability 1hr Deck Stability 8 hr 30000 Deck Stability 24 hr 0.01 0.1 1 10 μM ADP 0.75 Signal Stability 1 hr Signal Stabilty 8 hr 20000 0.50 0.25 0.1 μM ATP 1.0 μM ATP 10000 10 μM ATP 100 μM ATP 1.0 Signal Stability 24 hr 0.8 Deck Stability 8 hr Deck Stability 1 hr Deck Stability 24 hr 0.6 0.4 0.2 0.0 0.01 500 μM ATP 0.00 0.01 100 1.0 Relative Intensity mP 200 RFU B 250 350 Normalized Emission ) A Normalized Emission Excellent Sensitivity and Signal Stability at Initial Rate Conditions 0.1 1 10 0 0.1 100 1 10 0.1 μM ADP 1 10 100 % ATP Conversion % ATP Conversion % ATP Conversion Figure 3. The robust assay provides a large signal at low percent ATP conversion with excellent Z’. Also, the assays provide excellent reagent and signal stability (inset) shown for both signal and deck stability of up to 24 hours at room temperature using a 10 μM ATP/ADP standard curve. A) Standard curves for FP readout shown for 0.1, 1.0, 10, 100, and 1000 μM ATP. Excellent Z’ values of >0.7 were achieved at 3% ATP conversion for 1 μM, 10 μM, 100 μM, and 1000 μM ATP and 5% conversion for 0.1 μM ATP. B) Standard curves for TR-FRET readout shown for 0.1, 1.0, 10, 100, and 500 μM ATP. Excellent Z’ values of >0.5 were achieved at 2.5% ATP conversion for 10 μM, 100 μM and 500 μM ATP; 5% ATP conversion for 1 μM ATP; 10% ATP conversion for 0.1 μM ATP. C) Standard curves for FI readout shown for 0.1, 1.0, 10, and 100 μM ATP. Excellent Z’ values of >0.7 were achieved at 1% ATP conversion for 10 μM, and 100 μM ATP and 5% conversion for 0.1 μM and 1 μM ATP. PKA Titrations: Minimize Enzyme Requirements A B 250 C 2.0 60000 PKA + Substrate PKA - Substrate 50000 200 mP 100 40000 Raw RFU Ratio (665/620) 1.5 150 1.0 30000 20000 0.5 50 PKA + Substrate PKA - Substrate 0 0.001 0.01 0.1 1 PKA + Substrate PKA - Substrate 10 100 1000 0.0 0.001 10000 0.01 0.1 10000 1 mU/Rxn PKA 10 100 0 0.001 1000 10000 0.01 0.1 1 10 100 1000 10000 mU/Rxn PKA mU/Rxn PKA Figure 4. The high sensitivity of the Transcreener ADP2 Assays minimizes enzyme costs. Graphs show PKA is capable of catalyzing ATP hydrolysis with 400-fold less efficiency, relative to productive phosphorylation of substrate. PKA was titrated (1:2) in a 10μL assay volume with 10 μM ATP and 50 μM kemptide substrate (or without substrate) for one hour. Detection Mixture (10 μL) was added and reactions equilibrated for one hour before reading. Enzyme EC50 values show that excellent signal at low [enzyme] for each of the readouts. A) For FP, EC50 values = 1.9 and 793 mU/RXN with and without substrate. B) For TR-FRET, EC50 values = 1.2 and 458 mU/RXN. C) For FI, EC50 values = 1.5 and 454 mU/RXN. Inhibitor Dose Dependency Curves: Consistent Data for Each Transcreener ADP2 Assay 2.0 A 250 Staurosporine B Staurosporine Tyrphostin AG1478 mP 1.0 150 100 Go 6983 Tyrphostin AG1478 Relative Intensity 1.5 GO-6983 Ratio (665/620) 200 C H-89 H-89 1.0 0.5 0.8 0.6 Staurosporine Safire 2 H-89 Safire 2 0.4 50 Go-6983 Safire 2 Staurosporine SpectraM ax M 2 H-89 SpectraM ax M 2 0 0.1 1 10 100 1000 10000 100000 [inhibitor] (nM) 0.0 0.01 0.1 1 10 100 1000 [inhibitor] (nM) 10000 100000 0.2 0.01 Go-6983 SpectraM ax M 2 0.1 1 10 100 1000 10000 100000 [inhibitor] (nM) Transcreener ADP2 Figure 5. Accurate pharmacology is shown for each Assay. Dose dependency curves were generated for known PKA inhibitors by serially titrating into the PKA reaction conditions. A) For FP, IC50 values for Staurosporine, H-89 and GO-6983 were 37 nM, 179 nM and 9.0 μM respectively. B) For TR-FRET, IC50 values for Staurosporine, H-89 and GO-6983 were 58 nM, 283 nM and 9.3 μM respectively. C) For FI, similar IC50 values are shown using commonly used HTS and academic plate reader instruments (Safire2/SpectraMax M2) for Staurosporine, H89 and GO-6983 were 37/32 nM, 165/124 nM and 9.0/4.7 μM respectively. Conclusions Transcreener ADP2 Assays: Three detection modes. All major instrument platforms. Generic ADP assay for eazy development to HTS. The Transcreener ADP2 Assay is now offered in red emission spectra readouts for FP, TR-FRET, and FI readouts allowing compatibility with all instrument platforms. Transcreener assays directly detect ADP formed in the enzyme reaction in a single step, which eliminates false positives seen with technologies that use coupling enzymes prior to ADP detection. The new monoclonal ADP2 antibody has increased sensitivity and greater than 100-fold selectivity over ATP which enables its use from 0.1 µM to 1 mM ATP. ©2009 BellBrook Labs. All rights reserved. Transcreener® is a registered trademark of BellBrook Labs. Transcreener is a patented technology of BellBrook Labs. AlexaFluor® is a registered trademark and Lanthascreen™ is a trademark of Invitrogen. HiLyte Fluor™ is a trademark of AnaSpec, Inc. IRDye® is a registered trademark of LI-COR®. BellBrook Labs 5500 Nobel Drive, Suite 250, Madison, WI 53711 866.313.7881 or 608.443.2400 www.BellBrookLabs.com
© Copyright 2026 Paperzz