Fast Mineral Oil Analysis using LTM Matthew S. Klee, Ph.D. Agilent Technologies Wilmington, Delaware, USA 1 5990-4851EN 2 Mineral Oil Analysis (HOI: hydrocarbon oil index) • Mineral Oil analysis is in top 5 of current environmental analyses (next to VOCs, PAHs, pesticides) • Analysis is done by GC-FID (replaces old extraction – FTIR analysis) • Technique is similar to “TPH” (Total Petroleum Hydrocarbon) analyses done in the U.S.A. ... #1 LTM application in U.S.A. Ref: ISO 9377-2, ISO 9377-4, EN 14039, DIN H53,… 3 What is included in “Mineral Oil” analysis? Any mixture of compounds that: 1. are extracted by hydrocarbon solvent (from soil or water) 2. are not adsorbed by Florisil (used for cleanup) 3. elute from an apolar column between decane (C10) and tetracosane (C40) 4 Typical HOI analytical procedure 1. Extract Water: extract 1 L water with hexane Soil: extract by ASE 2. Clean-up Florisil (removes polar and semi-polar solutes such as sterols and lipids) 3. Concentrate to 1 mL N2 purge 4. Analyze extract by “discrimination free” injection, GCFID, area sum between C10 and C40 5 Analytical requirements Non-discriminatory injection: – COC • concerns about dirty samples – PTV – SSL (splitless) • concerns about discrimination against high boilers Low bleed column – Must elute C40 (thin film, high phase ratio) – Needs to separate solvent and 1st peak (decane) • can be problematic with splitless injection (wide solvent peak), so low initial temperature is required 6 Typical GC-FID conditions Agilent S/Sl: 1 µL injection in SL mode Others: COC or PTV (if S/Sl discriminates) Column: 5-25 m x 0.25-0.53 mm ID 0.1-0.5 µm HP-1 or HP-5 35-40°C init to 300-350°C Current disatisfier: Cycle time (~ 20-30 min without cool-dow) Limited ramp rate or lab GCs Cool-down time 7 80 4.207 pA 90 70 15 m x 0.53 mm id x 1.5 µm HP-1 He: 7.4 mL/min, constant flow 35°C (1.5 min) → 60°C@ 5°C/min → 350°C (5 min) @ 15°C/min 22.535 Typical Hydrocarbon Index Analysis by GC (Application note 5988-0621EN) 13.331 60 50 40 30 20 10 5 8 10 15 20 25 min “LTM” (Low Thermal Mass) Directly Heated Column Technology (Patented) 9 LTM System Installed on 7890A 10 The LTM Advantage • Total cycle time for an analysis can be cut by a factor of 3 or more (compared to same columns in air oven and LTM) • 1-4 independent column modules per GC – Dual column module configurations allow simultaneous parallel analyses – Each module can have a different column type – Temperature programs for modules are independent • Compatible with CFT devices for splitting, multidimensional separations, and/or for backflush 11 LTM method 1 (hot splitless) 1 µL splitless injection, 320°C GC oven: 340°C FID: 340°C LTM: 10 m x 0.32 mm ID x 0.1 µm DB-5HT • 40°C (0.5 min) → 240°C @ 200°C/min → 340°C (0.5 min) @ 100°C/min (3 min total) Carrier: He • 120 kPa (0.5 min) → 160 kPa @ 40 kPa/min → 180 kPa (0.5 min) @ 20 kPa/min 12 n-Alkane test mixture Response 2800000 C10 2400000 C20 2000000 1600000 C40 1200000 800000 400000 0 Time 13 0.00 0.20 0.40 0.60 0.80 1.00 1.20 1.40 1.60 1.80 2.00 2.20 2.40 2.60 2.80 n-Alkane test mixture Retention time repeatability (n=6) • C10: tR = 0.812 min, s = 0.001 min, RSD = 0.06% • C20: tR = 1.501 min, s < 0.001 min, RSD < 0.01% • C40: tR = 2.633 min, s = 0.003 min, RSD = 0.10% Peak Area repeatability • C10: mean area = 4265145, RSD = 0.86% • C20: mean area = 4578586, RSD = 1.05% • C40: mean area = 4117178, RSD = 0.85% Discrimination test • Relative peak area C40/C20 = 0.899 (RSD: 1.31%) (criterion: > 0.80) 14 Calibration diesel/motor oil 400 mg/L Response 2800000 Diesel 2400000 2000000 1600000 1200000 Motor oil 800000 400000 0 Time 15 0.20 0.40 0.60 0.80 1.00 1.20 1.40 1.60 1.80 2.00 2.20 2.40 2.60 2.80 Mineral Oil calibration Calibration from 40 – 1000 mg/L Linearity: r² > 0.999 Repeatability at 400 mg/L: • RSD on peak area = 0.64% LOD: < 25 mg/L 1200 R2 = 0.9991 Area (x10 -6) 1000 800 600 400 200 0 0 200 400 600 mg/L 16 800 1000 1200 Calibration 100 mg/L Response 550000 450000 350000 250000 150000 50000 Time 17 0.20 0.40 0.60 0.80 1.00 1.20 1.40 1.60 1.80 2.00 2.20 2.40 2.60 2.80 Extra benefit: sensitivity gain Response_ Signal: SENS-TEST07.D\FID1A.ch Signal: SENS-TEST05.D\FID1A.ch (*) 2800000 2600000 2400000 2200000 3 min run 2000000 1800000 21 min run 1600000 1400000 1200000 1000000 800000 600000 400000 200000 0 0.00 Time 18 2.00 4.00 6.00 8.00 10.00 12.00 14.00 16.00 18.00 20.00 HOI analysis with LTM - conclusions • Sample analysis cycle time is reduced to 5 min! • Analysis time: 3 min • Cool-down time to 40°C < 2 min • Meets all method requirements with hot splitless and Agilent ALS • Excellent repeatability, linearity • High sensitivity (“signal compression”) • Dual column module configuration with simultaneous injection and parallel analyses will maximize throughput 19 Thank you for you interest. Questions? This information is subject to change without notice. © Agilent Technologies, Inc. 2010 20
© Copyright 2026 Paperzz