GEOTHERMIE NEUBRANDENBURG GmbH Seestrasse 7 A; D-17033 Neubrandenburg phone: +49 (0) 395/3 67 74-0; fax: +49 (0) 395/3 67 74-11 [email protected] www.gtn-online.de Project sample: Reichstag Building and Integrated Energy Supply System of the Parliament Buildings in Berlin Client: Planungsgemeinschaft Technik für den Umbau des Reichstagsgebäudes zum Sitz des Deutschen Bundestages in Berlin und TVP Planungsgesellschaft Kuehn Bauer Partner Ingenieure GmbH Wilhelm-Wagenfeld-Strasse 6 D-80807 München Land/Region: Germany Period: 1996 - 2007 Project Description: The Parliament buildings in the Berlin Spree river curve incl. the Reichstag building covering a total floor area of approx. 240,000 m² are equipped with heating and cooling installations at the following temperature levels: Heating 110 °C/60 °C 45° C/30 °C (>60 %) Cooling 12 °C/6 °C 16 °C/19 °C (>60 %) Eight block-type cogeneration plants form the center of the energy production systems. They are consistently electricity-driven and supply primarily the inter-connected heating systems of the four buildings based on a centralized energy management. Absorption machines are driven as well. In summer, surplus heat is fed into the aquifer heat store at a temperature of 70 °C, recovered in winter and supplied at different points to the low-temperature heating networks of the integrated energy supply system. A second aquifer which is situated at a depth of approx. 50 m serves as a cold store. Groundwater is stored here which has been cooled to 5 °C by means of ambient cold or heat pumps in winter. In summer, it serves the base-load supply of the hightemperature cooling systems in the buildings. Contact for additional information: Dr. Frank Kabus GTN Services: Energy concept Licensing procedures under the Mining Code, Water Act, and Immission Control Act of Germany Numerical simulation of the aquifer store operation Design, call for bids, and supervision of the construction of the aquifer heat stores, blocktype cogeneration plants, boilers, heat pumps, chillers, primary heat, and cold supply systems Process monitoring and R&D Facts and Figures: Aquifer heat store o Effective horizon Hettangian o Depth 300 m o Wells 2 o Flow rate 100 m³/h Aquifer cold store o Effective horizon Quaternary o Depth 50 m o Wells 12 o Flow rate 300 m³/h Various block-type cogenerqation plants, 3,200 kWel Various hot water boilers, 13,000 kW Various absorption chillers/heat pumps, 2,000 kW Various compressor chillers, 200 … 650 kW
© Copyright 2026 Paperzz