Gas Detection for First Responders Patented Technology no false

Distributed BY: JAECO Fire & Safety, Phone: 650-964-6050, Fax: 650-215-2285, email: [email protected]
MIL-RAM TECHNOLOGY
Gas Detection for First Responders
Patented Technology
no false alarms
Single Gas Portable Instruments
Over 400 Available Sensors
Exotic Chemistry Solutions
Tel: 510-656-2001 ● Toll Free: 1-888-4MILRAM (1-888-464-5726)
Fax: 510-656-2004 ● Email: [email protected] ● Web: www.mil-ram.com
Distributed BY: JAECO Fire & Safety, Phone: 650-964-6050, Fax: 650-215-2285, email: [email protected]
MIL-RAM TECHNOLOGY
©
Single Gas Portable Instrument
Toxic/LEL/O2/VOC Gases
The TOX-BOX Single Gas Portable Instrument provides high resolution
measurement (16-bit analog-to-digital conversion) of any Mil-Ram
Toxic, LEL, O2 or VOC sensor with corresponding meter indication (16
character x 2 line LCD display) and local/external alarm function. The
TOX-BOX is housed in a rugged, weather-proof plastic instrument case
for dependable service under demanding field conditions. The instrument is easily configured through the operator interface consisting of
front panel push button switches and a large backlit LCD display (no dip
switches). Low, mid, high and fault relays can be used to activate external alarms and/or switch equipment on/off. The alarm relays are easily
configured for non-latching/latching, non-energized/energized and
0-255 sec. time delay. The alarm relays can be configured to trigger with
increasing or decreasing meter readings. Software filtering can be
enabled at various levels to offer increased stability in noisy electrical environments. A regenerated 4-20mA signal and/or
Modbus serial interface (optional) provides reliable connection to a data logger. Continuous diagnostics further ensures
system integrity and long-term stable operation and performance.
F
e
a
t
u
r
e
s
♦ no false alarms patented
sensor technology
♦ Available with any Mil-Ram
Toxic/LEL/O2/VOC Gas Sensor
♦ On-board pump continuously
draws gas sample past sensor
♦ Rechargeable 12 VDC sealed
lead-acid battery
♦ Rugged, weather-proof, portable
instrument enclosure
♦ Backlit LCD display and push
button switches
♦ Alarm Relays: Fully programmable
♦ Local Alarms: Buzzer and LED
indicators
♦ Regenerated 4-20mA Output
♦ Modbus RTU (optional)
♦ Low Battery Indicator
♦ Buzzer Silence Mode
♦ Alarm Disable Mode
♦ Digital Filter
♦ Continuous Diagnostics
♦ Flash Programming
Tel: 510-656-2001 ● Toll Free: 1-888-4MILRAM (1-888-464-5726)
Fax: 510-656-2004 ● Email: [email protected] ● Web: www.mil-ram.com
Distributed BY: JAECO Fire & Safety, Phone: 650-964-6050, Fax: 650-215-2285, email: [email protected]
Specifications
Alarm Relays
Low, mid, high and fault
SPST, 10 A @ 28 VDC, resistive
12 A @ 120 VAC, resistive
Relay Function
Front-Panel programmable for nonlatching/latching, non-energized/energized, 0-255
sec. time delay and alarm on increasing/decreasing reading. Fault relay factory set: non-latching,
normally non-energized and 0 sec. time delay
Instrument Type
Single Gas Portable
Part No.
01-2001TBS-XX
Input
Any Mil-Ram Toxic/LEL/O2/VOC gas sensor
Sensors
More than 400: Toxic, Oxygen, VOC and LEL
Combustible
Digital Filter
Selectable levels of digital filtering for increased
stability in noisy electrical environments
Range
Many ranges available-depends on gas type
Analog Output
Regenerated 4-20mA output (16-bit resolution)
for connection to data logger or chart recorder
Flow Rate
Up to 2 SCFH
Modbus RTU protocol
Power Source
Rechargeable lead-acid battery, 12 VDC
Serial Interface
(optional)
Power Rating
12 VDC @ 2.1W
Operating Temp.
-20°C to +50°C
-4°F to +122°F
Battery Charger
110 VAC operation
Rel. Humidity
5-95% non-condensing
Battery Life
>24 hours continuous/charge (most sensors)
Enclosure Type
Operator Interface
Back-lit LCD display (16 character x 2 lines)
4 push button switches (no dip switches)
All parameters front panel programmable
Plastic-ultra high impact structural copolymer,
neoprene o-ring, dust/water/chemical/corrosion
resistant. Colors: yellow, orange, or black
Enclosure
Dimensions
10 5/8 in. W x 9 3/4 in. H x 6 7/8 in. D
Options
RS-485 Modbus RTU, 2 or 4-wire
External Alarm Station
4-20mA Data Logger
Calibration Kits
Battery Charger
Continuous Operation Adapter
Alarm Levels
Local Alarms
Low, mid, high, and fault
Integral Buzzer, LED’s, LCD messages
Low Alarm: buzzer pulses, green LED
Mid Alarm: buzzer pulses faster, yellow LED
High Alarm: buzzer continuous, red LED
Fault Alarm: buzzer continuous, red LED
All alarm conditions accompanied by LCD messages
Specifications subject to change without notice
Mil-Ram Technology, Inc.
Patented Technology
no false alarms
Toll Free: (888) 4MILRAM ● (888) 464-5726
4135 Business Center Drive ● Fremont, CA 94538
Tel: (510) 656-2001 ● Fax: (510) 656-2004
Distributed BY: JAECO Fire & Safety, Phone: 650-964-6050, Fax: 650-215-2285, email: [email protected]
MIL-RAM TECHNOLOGY
©
Natural Gas Pipeline
Carbon Dioxide, CO2
Portable Analyzer
The TOX-BOX Single Gas Portable Instrument provides
high resolution measurement (16-bit analog-to-digital
conversion) of Carbon Dioxide gas utilizing Mil-Ram’s
non-dispersive infrared (NDIR) sensor technology. The
TOX-BOX efficiently and accurately measures CO2
contaminant levels in natural gas pipelines with simple
connection to a positive pressure sample line. The TOXBOX is housed in a rugged, weather-proof, plastic instrument enclosure for dependable service under demanding field conditions. The instrument is easily configured through the
operator interface consisting of front panel push button switches and a large backlit LCD display (no dip switches). Low,
mid, and high fault relays can be used to activate external alarms and/or switch equipment on/off. The alarm relays are easily
configured for non-latching/latching, non-energized/energized and 0-255 sec. time delay. The alarm relays can be configured
to trigger with increasing or decreasing meter readings. Software filtering can be enabled at various levels to offer increased
stability in noisy electrical environments. A regenerated 4-20mA signal and/or Modbus serial interface (optional) provides
reliable connection to a data logger. Continuous diagnostics further ensures system integrity and long-term stable operation
and performance.
F
e
a
t
u
r
e
s
♦ no false alarms Infrared
(NDIR) sensor technology
♦ Flow meter and coalescing filter
♦ Rechargeable 12 VDC sealed
lead-acid battery: >12 hrs./charge
♦ Rugged, weather-proof, portable
instrument enclosure
♦ Backlit LCD display and push
button switches
♦ Alarm Relays: Fully programmable
♦ Local Alarms: Buzzer and LED
indicators
♦ Regenerated 4-20mA Output
♦ Modbus RTU (optional)
♦ Low Battery Indicator
♦ Buzzer Silence Mode
♦ Alarm Disable Mode
♦ Digital Filter
♦ Continuous Diagnostics
♦ Flash Programming
Tel: 510-656-2001 ● Toll Free: 1-888-4MILRAM (1-888-464-5726)
Fax: 510-656-2004 ● Email: [email protected] ● Web: www.mil-ram.com
Distributed BY: JAECO Fire & Safety, Phone: 650-964-6050, Fax: 650-215-2285, email: [email protected]
Specifications
Instrument Type
Single Gas Portable
Part No.
01-2001TBF-89
Sensor
Non-dispersive infrared for CO2
(other models available for H2S)
Alarm Relays
Low, mid, high and fault
SPST, 10 A @ 28 VDC, resistive
12 A @ 120 VAC, resistive
Relay Function
Front-Panel programmable for nonlatching/latching, non-energized/energized, 0-255
sec. time delay and alarm on increasing/decreasing reading. Fault relay factory set: non-latching,
normally non-energized and 0 sec. time delay
Digital Filter
Selectable levels of digital filtering for increased
stability in noisy electrical environments
Analog Output
Regenerated 4-20mA output (16-bit resolution)
for connection to data logger or chart recorder
Range
0.0-5.0% Vol. (other ranges available)
Inlet Pressure
Up to 25 psig
Power Source
Rechargeable sealed lead-acid battery,
12 VDC
Serial Interface
(optional)
Modbus RTU protocol
Power Rating
12 VDC @ 2.1W
Operating Temp.
-20°C to +50°C
-4°F to +122°F
Battery Charger
110 VAC operation
Rel. Humidity
5-95% non-condensing
Battery Life
>12 hours continuous/charge
Enclosure Type
Operator Interface
Back-lit LCD display (16 character x 2 lines)
4 push button switches (no dip switches)
All parameters front panel programmable
Plastic-ultra high impact structural copolymer,
neoprene o-ring, dust/water/chemical/corrosion
resistant. Color: black (yellow or orange avail.)
Enclosure
Dimensions
10 5/8 in. W x 9 3/4 in. H x 6 7/8 in. D
Options
RS-485 Modbus RTU, 2 or 4-wire
External Alarm Station
4-20mA Data Logger
Calibration Kits
Battery Charger
Continuous Operation Adapter
Alarm Levels
Low, mid, high, and fault
Local Alarms
Integral Buzzer, LED’s, LCD messages
Low Alarm: buzzer pulses, green LED
Mid Alarm: buzzer pulses faster, yellow LED
High Alarm: buzzer continuous, red LED
Fault Alarm: buzzer continuous, red LED
All alarm conditions accompanied by LCD messages
Specifications subject to change without notice
Mil-Ram Technology, Inc.
Patented Technology
no false alarms
Toll Free: (888) 4MILRAM ● (888) 464-5726
4135 Business Center Drive ● Fremont, CA 94538
Tel: (510) 656-2001 ● Fax: (510) 656-2004
Distributed BY: JAECO Fire & Safety, Phone: 650-964-6050, Fax: 650-215-2285, email: [email protected]
Gas List: Partial
Gas Name
Symbol
Acetic Acid
CH3CO2H
Acetone
(CH3)2CO
Acrylonitrile
C3H3N
Alcohol
CH3OH
Ammonia
NH3
Antimony Pentachloride
SbCl5
Arsenic Pentachloride
AsCl5
Arsenic Pentafluoride
AsF5
Arsenic Trichloride
AsCl3
Arsenic Trifluoride
AsF3
Arsine
AsH3
Benzene
C6H6
Boron Trichloride
BCl3
Boron Trifluoride
BF3
Bromine
Br2
Carbon Dioxide
CO2
Carbon Monoxide
CO
Carbon Tetrachloride
CCl4
Carbonyl Difluoride
COF2
Chlorine
Cl2
Chlorine Dioxide
ClO2
Chlorine Trifluoride
ClF3
Chloro­Benzene
C6H5Cl
Chloro­Fluorocarbons
CFCs
Chloroform
CHCl3
Combustibles
LEL
Diborane
B2H6
Dichloroethane
C2H4Cl2
Dichlorosilane
SiH2Cl2
Difluoromethane
CH2F2
Disilane
Si2H6
Fluorine
F2
Fluorosulfonic Acid
HSO3F
Germane
GeH4
Germanium Tetrachloride
GeCl4
Germanium Trichloride
GeCl3
Halon 1211
Halon 1211
Halon 1301
Halon 1301
Halon 2402
Halon 2402
HCFCs (Freons)
Freons
Hexane
C6H14
* Other Ranges Available­­Consult Factory
Detection Range *
0­100 %LEL
0­100 %LEL
0­200 ppm
0­100 %LEL
0­200 ppm
0.0­20.0 ppm
0.0­20.0 ppm
0.0­20.0 ppm
0.0­20.0 ppm
0.0­20.0 ppm
0.0­1.00 ppm
0­100 %LEL
0.0­20.0 ppm
0.0­20.0 ppm
0.0­5.0 ppm
0­2 %Vol
0­200 ppm
0­100 ppm
0.0­20.0 ppm
0.0­5.0 ppm
0.0­5.0 ppm
0.0­20.0 ppm
0­100 ppm
0­100 ppm
0­100 ppm
0­100 %LEL
0.0­1.00 ppm
0­100 ppm
0.0­20.0 ppm
0­100 ppm
0.0­1.00 ppm
0.0­5.0 ppm
0.0­20.0 ppm
0.0­5.0 ppm
0.0­20.0 ppm
0.0­20.0 ppm
0­100 ppm
0­100 ppm
0­100 ppm
0­100 ppm
0­100 %LEL
1
Distributed BY: JAECO Fire & Safety, Phone: 650-964-6050, Fax: 650-215-2285, email: [email protected]
Gas List: Partial
Gas Name
Symbol
Hydrazine
N2H4
Hydrogen
H2
Hydrogen Bromide
HBr
Hydrogen Chloride
HCl
Hydrogen Cyanide
HCN
Hydrogen Fluoride
HF
Hydrogen Iodide
HI
Hydrogen Peroxide
H2O2
Hydrogen Sulfide
H2 S
Iodine
I2
Isopropyl Alcohol
C3H7OH
Methane
CH4
Methyl Bromide
CH3Br
Methyl Chloride
CH3Cl
Methyl Iodide
CH3I
Methyl Chloroform
C2H3Cl3
Methylene Chloride
CH2Cl2
Molybdenum Fluoride
MoF4
Molybdenum Hexafluoride
MoF6
Molybdenum Pentachloride MoCl5
Nitric Acid Vapors
HNO3
Nitric Oxide
NO
Nitrogen Dioxide
NO2
Nitrogen Trifluoride
NF3
Nitrogen Tetroxide
N2O4
Oxygen
O2
Ozone
O3
Phosgene
COCl2
Phosphine
PH3
Phosphorous Oxychloride
POCl3
Phosphorous Pentachloride
PCl5
Phosphorous Pentafluoride
PF5
Phosphorous Trichloride
PCl3
Phosphorous Trifluoride
PF3
Propane
C5H12
Silane
SiH4
Silicon Tetrachloride
SiCl4
Silicon Tetrafluoride
SiF4
Sulfur Dioxide
SO2
Sulfur Tetrafluoride
SF4
* Other Ranges Available­­Consult Factory
Detection Range *
0.0­1.00 ppm
0­100 %LEL
0.0­20.0 ppm
0.0­20.0 ppm
0­50 ppm
0.0­20.0 ppm
0.0­20.0 ppm
0.0­5.0 ppm
0­50 ppm
0.0­5.0 ppm
0­100 %LEL
0­100 %LEL
0­200 ppm
0­200 ppm
0­200 ppm
0­100 ppm
0­100 ppm
0.0­20.0 ppm
0.0­20.0 ppm
0.0­20.0 ppm
0.0­20.0 ppm
0­100 ppm
0.0­20.0 ppm
0­100 ppm
0.0­20.0 ppm
0.0­25.0 %Vol
0.0­20.0 ppm
0.0­1.00 ppm
0.0­1.00 ppm
0.0­20.0 ppm
0.0­20.0 ppm
0.0­20.0 ppm
0.0­20.0 ppm
0.0­20.0 ppm
0­100 %LEL
0.0­50.0 ppm
0.0­20.0 ppm
0.0­20.0 ppm
0.0­20.0 ppm
0.0­20.0 ppm
2
Distributed BY: JAECO Fire & Safety, Phone: 650-964-6050, Fax: 650-215-2285, email: [email protected]
Gas List: Partial
Gas Name
Symbol
Sulfuric Acid Vapors
H2SO4
Tantalum Fluoride
TaF5
Tetrachloroethylene
C2Cl4
Tetraethyl­Orthosilicate
TEOS
Tin Tetrachloride
SnCl4
Titanium Fluoride
TiF4
Titanium Tetrachloride
TiCl3
Trichloroethylene
C2HCl3
Trichlorosilane
SiHCl3
Tungsten Hexachloride
WCl6
Tungsten Hexafluoride
WF6
Vinyl Chloride
CH2CHCl
Many More
* Other Ranges Available­­Consult Factory
Detection Range *
0.0­20.0 ppm
0.0­20.0 ppm
0­100 ppm
0­100 ppm
0.0­20.0 ppm
0.0­20.0 ppm
0.0­20.0 ppm
0­100 ppm
0.0­20.0 ppm
0.0­20.0 ppm
0.0­20.0 ppm
0­100 ppm
VOCs
Alcohols
Aldehydes
Amides
Amines
Aromatics
Chloro­Hydrocarbons
Hydrocarbons
Ketones
Sulfur Compounds
Many More
3