Distributed BY: JAECO Fire & Safety, Phone: 650-964-6050, Fax: 650-215-2285, email: [email protected] MIL-RAM TECHNOLOGY Gas Detection for First Responders Patented Technology no false alarms Single Gas Portable Instruments Over 400 Available Sensors Exotic Chemistry Solutions Tel: 510-656-2001 ● Toll Free: 1-888-4MILRAM (1-888-464-5726) Fax: 510-656-2004 ● Email: [email protected] ● Web: www.mil-ram.com Distributed BY: JAECO Fire & Safety, Phone: 650-964-6050, Fax: 650-215-2285, email: [email protected] MIL-RAM TECHNOLOGY © Single Gas Portable Instrument Toxic/LEL/O2/VOC Gases The TOX-BOX Single Gas Portable Instrument provides high resolution measurement (16-bit analog-to-digital conversion) of any Mil-Ram Toxic, LEL, O2 or VOC sensor with corresponding meter indication (16 character x 2 line LCD display) and local/external alarm function. The TOX-BOX is housed in a rugged, weather-proof plastic instrument case for dependable service under demanding field conditions. The instrument is easily configured through the operator interface consisting of front panel push button switches and a large backlit LCD display (no dip switches). Low, mid, high and fault relays can be used to activate external alarms and/or switch equipment on/off. The alarm relays are easily configured for non-latching/latching, non-energized/energized and 0-255 sec. time delay. The alarm relays can be configured to trigger with increasing or decreasing meter readings. Software filtering can be enabled at various levels to offer increased stability in noisy electrical environments. A regenerated 4-20mA signal and/or Modbus serial interface (optional) provides reliable connection to a data logger. Continuous diagnostics further ensures system integrity and long-term stable operation and performance. F e a t u r e s ♦ no false alarms patented sensor technology ♦ Available with any Mil-Ram Toxic/LEL/O2/VOC Gas Sensor ♦ On-board pump continuously draws gas sample past sensor ♦ Rechargeable 12 VDC sealed lead-acid battery ♦ Rugged, weather-proof, portable instrument enclosure ♦ Backlit LCD display and push button switches ♦ Alarm Relays: Fully programmable ♦ Local Alarms: Buzzer and LED indicators ♦ Regenerated 4-20mA Output ♦ Modbus RTU (optional) ♦ Low Battery Indicator ♦ Buzzer Silence Mode ♦ Alarm Disable Mode ♦ Digital Filter ♦ Continuous Diagnostics ♦ Flash Programming Tel: 510-656-2001 ● Toll Free: 1-888-4MILRAM (1-888-464-5726) Fax: 510-656-2004 ● Email: [email protected] ● Web: www.mil-ram.com Distributed BY: JAECO Fire & Safety, Phone: 650-964-6050, Fax: 650-215-2285, email: [email protected] Specifications Alarm Relays Low, mid, high and fault SPST, 10 A @ 28 VDC, resistive 12 A @ 120 VAC, resistive Relay Function Front-Panel programmable for nonlatching/latching, non-energized/energized, 0-255 sec. time delay and alarm on increasing/decreasing reading. Fault relay factory set: non-latching, normally non-energized and 0 sec. time delay Instrument Type Single Gas Portable Part No. 01-2001TBS-XX Input Any Mil-Ram Toxic/LEL/O2/VOC gas sensor Sensors More than 400: Toxic, Oxygen, VOC and LEL Combustible Digital Filter Selectable levels of digital filtering for increased stability in noisy electrical environments Range Many ranges available-depends on gas type Analog Output Regenerated 4-20mA output (16-bit resolution) for connection to data logger or chart recorder Flow Rate Up to 2 SCFH Modbus RTU protocol Power Source Rechargeable lead-acid battery, 12 VDC Serial Interface (optional) Power Rating 12 VDC @ 2.1W Operating Temp. -20°C to +50°C -4°F to +122°F Battery Charger 110 VAC operation Rel. Humidity 5-95% non-condensing Battery Life >24 hours continuous/charge (most sensors) Enclosure Type Operator Interface Back-lit LCD display (16 character x 2 lines) 4 push button switches (no dip switches) All parameters front panel programmable Plastic-ultra high impact structural copolymer, neoprene o-ring, dust/water/chemical/corrosion resistant. Colors: yellow, orange, or black Enclosure Dimensions 10 5/8 in. W x 9 3/4 in. H x 6 7/8 in. D Options RS-485 Modbus RTU, 2 or 4-wire External Alarm Station 4-20mA Data Logger Calibration Kits Battery Charger Continuous Operation Adapter Alarm Levels Local Alarms Low, mid, high, and fault Integral Buzzer, LED’s, LCD messages Low Alarm: buzzer pulses, green LED Mid Alarm: buzzer pulses faster, yellow LED High Alarm: buzzer continuous, red LED Fault Alarm: buzzer continuous, red LED All alarm conditions accompanied by LCD messages Specifications subject to change without notice Mil-Ram Technology, Inc. Patented Technology no false alarms Toll Free: (888) 4MILRAM ● (888) 464-5726 4135 Business Center Drive ● Fremont, CA 94538 Tel: (510) 656-2001 ● Fax: (510) 656-2004 Distributed BY: JAECO Fire & Safety, Phone: 650-964-6050, Fax: 650-215-2285, email: [email protected] MIL-RAM TECHNOLOGY © Natural Gas Pipeline Carbon Dioxide, CO2 Portable Analyzer The TOX-BOX Single Gas Portable Instrument provides high resolution measurement (16-bit analog-to-digital conversion) of Carbon Dioxide gas utilizing Mil-Ram’s non-dispersive infrared (NDIR) sensor technology. The TOX-BOX efficiently and accurately measures CO2 contaminant levels in natural gas pipelines with simple connection to a positive pressure sample line. The TOXBOX is housed in a rugged, weather-proof, plastic instrument enclosure for dependable service under demanding field conditions. The instrument is easily configured through the operator interface consisting of front panel push button switches and a large backlit LCD display (no dip switches). Low, mid, and high fault relays can be used to activate external alarms and/or switch equipment on/off. The alarm relays are easily configured for non-latching/latching, non-energized/energized and 0-255 sec. time delay. The alarm relays can be configured to trigger with increasing or decreasing meter readings. Software filtering can be enabled at various levels to offer increased stability in noisy electrical environments. A regenerated 4-20mA signal and/or Modbus serial interface (optional) provides reliable connection to a data logger. Continuous diagnostics further ensures system integrity and long-term stable operation and performance. F e a t u r e s ♦ no false alarms Infrared (NDIR) sensor technology ♦ Flow meter and coalescing filter ♦ Rechargeable 12 VDC sealed lead-acid battery: >12 hrs./charge ♦ Rugged, weather-proof, portable instrument enclosure ♦ Backlit LCD display and push button switches ♦ Alarm Relays: Fully programmable ♦ Local Alarms: Buzzer and LED indicators ♦ Regenerated 4-20mA Output ♦ Modbus RTU (optional) ♦ Low Battery Indicator ♦ Buzzer Silence Mode ♦ Alarm Disable Mode ♦ Digital Filter ♦ Continuous Diagnostics ♦ Flash Programming Tel: 510-656-2001 ● Toll Free: 1-888-4MILRAM (1-888-464-5726) Fax: 510-656-2004 ● Email: [email protected] ● Web: www.mil-ram.com Distributed BY: JAECO Fire & Safety, Phone: 650-964-6050, Fax: 650-215-2285, email: [email protected] Specifications Instrument Type Single Gas Portable Part No. 01-2001TBF-89 Sensor Non-dispersive infrared for CO2 (other models available for H2S) Alarm Relays Low, mid, high and fault SPST, 10 A @ 28 VDC, resistive 12 A @ 120 VAC, resistive Relay Function Front-Panel programmable for nonlatching/latching, non-energized/energized, 0-255 sec. time delay and alarm on increasing/decreasing reading. Fault relay factory set: non-latching, normally non-energized and 0 sec. time delay Digital Filter Selectable levels of digital filtering for increased stability in noisy electrical environments Analog Output Regenerated 4-20mA output (16-bit resolution) for connection to data logger or chart recorder Range 0.0-5.0% Vol. (other ranges available) Inlet Pressure Up to 25 psig Power Source Rechargeable sealed lead-acid battery, 12 VDC Serial Interface (optional) Modbus RTU protocol Power Rating 12 VDC @ 2.1W Operating Temp. -20°C to +50°C -4°F to +122°F Battery Charger 110 VAC operation Rel. Humidity 5-95% non-condensing Battery Life >12 hours continuous/charge Enclosure Type Operator Interface Back-lit LCD display (16 character x 2 lines) 4 push button switches (no dip switches) All parameters front panel programmable Plastic-ultra high impact structural copolymer, neoprene o-ring, dust/water/chemical/corrosion resistant. Color: black (yellow or orange avail.) Enclosure Dimensions 10 5/8 in. W x 9 3/4 in. H x 6 7/8 in. D Options RS-485 Modbus RTU, 2 or 4-wire External Alarm Station 4-20mA Data Logger Calibration Kits Battery Charger Continuous Operation Adapter Alarm Levels Low, mid, high, and fault Local Alarms Integral Buzzer, LED’s, LCD messages Low Alarm: buzzer pulses, green LED Mid Alarm: buzzer pulses faster, yellow LED High Alarm: buzzer continuous, red LED Fault Alarm: buzzer continuous, red LED All alarm conditions accompanied by LCD messages Specifications subject to change without notice Mil-Ram Technology, Inc. Patented Technology no false alarms Toll Free: (888) 4MILRAM ● (888) 464-5726 4135 Business Center Drive ● Fremont, CA 94538 Tel: (510) 656-2001 ● Fax: (510) 656-2004 Distributed BY: JAECO Fire & Safety, Phone: 650-964-6050, Fax: 650-215-2285, email: [email protected] Gas List: Partial Gas Name Symbol Acetic Acid CH3CO2H Acetone (CH3)2CO Acrylonitrile C3H3N Alcohol CH3OH Ammonia NH3 Antimony Pentachloride SbCl5 Arsenic Pentachloride AsCl5 Arsenic Pentafluoride AsF5 Arsenic Trichloride AsCl3 Arsenic Trifluoride AsF3 Arsine AsH3 Benzene C6H6 Boron Trichloride BCl3 Boron Trifluoride BF3 Bromine Br2 Carbon Dioxide CO2 Carbon Monoxide CO Carbon Tetrachloride CCl4 Carbonyl Difluoride COF2 Chlorine Cl2 Chlorine Dioxide ClO2 Chlorine Trifluoride ClF3 ChloroBenzene C6H5Cl ChloroFluorocarbons CFCs Chloroform CHCl3 Combustibles LEL Diborane B2H6 Dichloroethane C2H4Cl2 Dichlorosilane SiH2Cl2 Difluoromethane CH2F2 Disilane Si2H6 Fluorine F2 Fluorosulfonic Acid HSO3F Germane GeH4 Germanium Tetrachloride GeCl4 Germanium Trichloride GeCl3 Halon 1211 Halon 1211 Halon 1301 Halon 1301 Halon 2402 Halon 2402 HCFCs (Freons) Freons Hexane C6H14 * Other Ranges AvailableConsult Factory Detection Range * 0100 %LEL 0100 %LEL 0200 ppm 0100 %LEL 0200 ppm 0.020.0 ppm 0.020.0 ppm 0.020.0 ppm 0.020.0 ppm 0.020.0 ppm 0.01.00 ppm 0100 %LEL 0.020.0 ppm 0.020.0 ppm 0.05.0 ppm 02 %Vol 0200 ppm 0100 ppm 0.020.0 ppm 0.05.0 ppm 0.05.0 ppm 0.020.0 ppm 0100 ppm 0100 ppm 0100 ppm 0100 %LEL 0.01.00 ppm 0100 ppm 0.020.0 ppm 0100 ppm 0.01.00 ppm 0.05.0 ppm 0.020.0 ppm 0.05.0 ppm 0.020.0 ppm 0.020.0 ppm 0100 ppm 0100 ppm 0100 ppm 0100 ppm 0100 %LEL 1 Distributed BY: JAECO Fire & Safety, Phone: 650-964-6050, Fax: 650-215-2285, email: [email protected] Gas List: Partial Gas Name Symbol Hydrazine N2H4 Hydrogen H2 Hydrogen Bromide HBr Hydrogen Chloride HCl Hydrogen Cyanide HCN Hydrogen Fluoride HF Hydrogen Iodide HI Hydrogen Peroxide H2O2 Hydrogen Sulfide H2 S Iodine I2 Isopropyl Alcohol C3H7OH Methane CH4 Methyl Bromide CH3Br Methyl Chloride CH3Cl Methyl Iodide CH3I Methyl Chloroform C2H3Cl3 Methylene Chloride CH2Cl2 Molybdenum Fluoride MoF4 Molybdenum Hexafluoride MoF6 Molybdenum Pentachloride MoCl5 Nitric Acid Vapors HNO3 Nitric Oxide NO Nitrogen Dioxide NO2 Nitrogen Trifluoride NF3 Nitrogen Tetroxide N2O4 Oxygen O2 Ozone O3 Phosgene COCl2 Phosphine PH3 Phosphorous Oxychloride POCl3 Phosphorous Pentachloride PCl5 Phosphorous Pentafluoride PF5 Phosphorous Trichloride PCl3 Phosphorous Trifluoride PF3 Propane C5H12 Silane SiH4 Silicon Tetrachloride SiCl4 Silicon Tetrafluoride SiF4 Sulfur Dioxide SO2 Sulfur Tetrafluoride SF4 * Other Ranges AvailableConsult Factory Detection Range * 0.01.00 ppm 0100 %LEL 0.020.0 ppm 0.020.0 ppm 050 ppm 0.020.0 ppm 0.020.0 ppm 0.05.0 ppm 050 ppm 0.05.0 ppm 0100 %LEL 0100 %LEL 0200 ppm 0200 ppm 0200 ppm 0100 ppm 0100 ppm 0.020.0 ppm 0.020.0 ppm 0.020.0 ppm 0.020.0 ppm 0100 ppm 0.020.0 ppm 0100 ppm 0.020.0 ppm 0.025.0 %Vol 0.020.0 ppm 0.01.00 ppm 0.01.00 ppm 0.020.0 ppm 0.020.0 ppm 0.020.0 ppm 0.020.0 ppm 0.020.0 ppm 0100 %LEL 0.050.0 ppm 0.020.0 ppm 0.020.0 ppm 0.020.0 ppm 0.020.0 ppm 2 Distributed BY: JAECO Fire & Safety, Phone: 650-964-6050, Fax: 650-215-2285, email: [email protected] Gas List: Partial Gas Name Symbol Sulfuric Acid Vapors H2SO4 Tantalum Fluoride TaF5 Tetrachloroethylene C2Cl4 TetraethylOrthosilicate TEOS Tin Tetrachloride SnCl4 Titanium Fluoride TiF4 Titanium Tetrachloride TiCl3 Trichloroethylene C2HCl3 Trichlorosilane SiHCl3 Tungsten Hexachloride WCl6 Tungsten Hexafluoride WF6 Vinyl Chloride CH2CHCl Many More * Other Ranges AvailableConsult Factory Detection Range * 0.020.0 ppm 0.020.0 ppm 0100 ppm 0100 ppm 0.020.0 ppm 0.020.0 ppm 0.020.0 ppm 0100 ppm 0.020.0 ppm 0.020.0 ppm 0.020.0 ppm 0100 ppm VOCs Alcohols Aldehydes Amides Amines Aromatics ChloroHydrocarbons Hydrocarbons Ketones Sulfur Compounds Many More 3
© Copyright 2026 Paperzz