980mm deep below C.L. surface water sewer 4.160 Existing wall built up to new gable area +9.959 New roof area over kitchen New manhole 1500mm turning circle 3.190 Extension with rendered wall finish NEW BEDROOM A: 14.920 m2 Front Elevation Rear garden A: 4.844 m2 UTILITY 1.200 3.175 Drainage channel 1.000 OFFICE A: 4.324 m2 A: 15.059 m2 Slope up 1.760 Rear lobby Patio A: 5.190 m2 W.C. A: 3.984 m2 A: 2.715 m2 1:100 Fire resistant glazing to window screen CONSERVATORY Wheelchair height worktop EXTENDED KITCHEN AREA A: 10.704 m2 Floor level to be level with main dining room Waste gully Side Elevation Timber fence SCFD 30s optional doorway Conservatory Rendered wall finish 1.800 SCFD 30s 4.560 Boundary line 1.500 1.200 1.800 +9.945 Dryer W under 9.890 Wash W machine under Drainage channel 1:100 Extension New manhole SCFD 30s New manhole drainage run altered Back Elevation 1.200 EN-SUITE 1:100 Conservatory New roof extended over existing kitchen area 9.890 New extension 2 BEDROOM 1 Bi fold doors 2 4.180 Beam built in over 2 BATHROOM opening widened to 1200mm wide DINING ROOM 2 Area 14.7m² 2 KITCHEN 2 South Elevation HALL 2 up 50mm Gas fire T BATHROOM C/B SITTING ROOM/ BEDROOM 3 Area 16.0m² 1:100 Water heater 2 BEDROOM 2 Rendered wall finish Soil pipe gully RW pipe T Obscure glazing 2 Area 14.7m² SCFD Obscure glazing Existing rendered wall finish +10.728 2 Area 15.5m² 2.810 +10.000 2 2 980mm deep below C.L. surface water sewer T +9.959 RW pipe & gully +9.802 ramp up 2 2 +9.771 Water 2 heater ramp up 2 ramp up 2.994 Rear garden hedging T +9.945 Extract fan hood over KITCHEN Boundary line Patio Timber fence This drawing must not be scaled. dimensions, levels etc only are to be used and any discrepancies, inaccurances etc must be reported to 'M. Swain Architectural and Surveying Services.' Detail drawings. & larger scale drawings take precedence over smaller scale drawings. 2 2.530 Front garden area +9.710 Revision A - 10-04-2012, Amendments following site meeting with client The contractor is to comply in all respects with current British Standards specifications, Building Regulations, Statutary Authority Regulations and requirements etc- whether or not specifically stated on this drawing or not 2 up 50mm RW pipe parking area Soil gully pipe This Drawing is Copyright. 2 M .P.S. Surveying & Architectural Design Ltd 23A Monk Street, Abergavenny, Monmouthshire, NP7 5LD Client: 4.090 SITTING AREA Front garden area STATUS: parking area Planning Tel. No. (01873) 852841 Mobile 07812741196 Email: MPSsurveying@ aol.com T DATE: February 2012 2 2 3.130 PROJECT: Water stop valve Proposed extension at: The Cedars, Usk Road, Raglan Monmouthshire, NP15 2EB +9.710 +9.714 Boundary wall +9.641 +9.822 +9.783 Boundary wall DRAWING TITLE: Pavement SCALE: Ground floor plan 1:50 Site plan 1:200 Initial Proposed plans, and elevations for discussion with the client As shown DRAWING No. 11145 - 02 A Rear 3D view Front 3D View Sectional view B This drawing must not be scaled. dimensions, levels etc only are to be used and any discrepancies, inaccurances etc must be reported to 'M. Swain Architectural and Surveying Services.' Detail drawings & larger scale drawings take precedence over smaler scal drawings. This Drawing is Copyright. Client #Client Top colour view of rooms STATUS: DESIGN DRAWING DATE: February 2012 PROJECT: DRAWING TITLE: SCALE: Mike Swain Surveying & Architectural Services 15 Clifton Road, Abergavenny, Monmouthshire NP7 6AG Tel. No. (01873) 852841 Mobile 07812741196 Email: MPSsurveying@ aol.com Proposed extension at: The Cedars, Usk Road, Raglan Monmouthshire, NP15 2EB 3D Views for the proposals As shown DRAWING No. 11145 -03
© Copyright 2026 Paperzz