Installation and maintenance instructions for Altro Lavencia™ Click Before you start • • Altro Lavencia Click is normally loose laid without adhesive, although full • • It is essential to perform moisture testing per ASTM F2170 (internal relative in wet areas or those with heavy rolling loads, please consult Altro technical loose lay click tiles and to be less than <85% percent when the tiles are to space at all other abutments that cannot be undercut or placed on top of department if this applies to your installation. be glued down in place. pH testing must be performed per ASTM F710, the tile. results not to exceed 9.9. Warranty Subfloors must be structurally sound, solid, stable, level, plumb and true to 20 year commercial warranty / Lifetime residential warranty possible and allow to condition in room where installation is to take place at a tolerance in plane of 3/16” in 10 feet (6 mm in 4m). Cracks and holes Our limited commercial warranty for Altro Lavencia means that for ten years a constant temperature of 68° to 77° degrees Fahrenheit (20° to 25° C) must be filled with a fast setting cement-based polymer modified patching for a period of 24 hours prior to installation. compound or equivalent. Any unevenness over 3/16” (4.7mm) must • Check Altro Lavencia Click for possible defects prior the installation. residue etc. Carpet staples or adhesive residue should be removed prior Complaints can only be accepted before installation. Slight variations in to installation. Voids or humps in the subfloor will prevent the tiles from color and structure are designed to enhance natural appearance. Mixing the locking properly. tiles creates a more natural appearance. • Concrete shall be constructed per the guidelines contained in the ACI Be aware that when exposed to excessive temperatures and direct sunlight (American Concrete Institute) 302.2R-06: Guide for Concrete Slabs that Altro Lavencia Click if loose laid may expand and contract causing problems Receive Moisture-Sensitive Flooring Materials http://bit.ly/WHhkeH with the locking system. Please consider these exposures when choosing • your product and deciding if the product will require it being glued down in Altro Lavencia Click can be installed on existing firm floors (Linoleum, PVC...), place. but all textile floors must be removed. When laying the floor over existing ceramic In facilities where walkers, wheel chairs are present, or in facilities with movement of heavy displays, racks, dentist chairs patient beds, etc. These types of installations may exert extreme stress and compromise the locking system. Therefore it is recommended that these installations be installed glued down. Please consult your Altro representative or Altro Technical tiles first level with a fast setting cement-based polymer modified patching compound. Determine if there is a need for noise reduction. Many residential applications like condos and senior living facilities require noise suppression For application in direct sunlight or exposure to excessive heat or in areas with maintained according to instructions. This guarantee applies only to the original heavy rolling traffic i.e. Dentists chairs, wheelchairs or dollies it is recommended end user and proof of purchase is required for all claims. The guarantee is for to glue Altro Lavencia Click down and permanently into place in these areas. replacement or refund of the material only, no labor. Claims for wear must show a minimum dime size area. High-heeled shoes, rolling carts, furniture and chairs without protective pads can damage the floor and are not covered by this warranty. The warranty forms can be downloaded from our website www.altro.com/downloads Installation Different production runs Vinyl floors can have slight color variations in between production runs. Before starting the installation, it is best to check the production run # the main light-source is recommended for best visual effects. between floors. Altro recommends using Altro Hush acoustic underlay Adhesives (for direct sunlight/heavy load areas) 1. Altrofix 25 one-part acrylic pressure sensitive adhesive is the recommended adhesive. 2. Do not install over concrete floors that are excessively cold or radiantheated floors with temperatures that exceed 85°F (25°C). Radiant heating should be turned off 12 hours before commencing installation. 3. The trowel size to be used is a U notch trowel of 1/32” inch deep notch, by 1/16” wide notch, by 1/32” apart spacing between notches (Gundlach 680-FFA trowel). Agree on which direction the floor boards should run since this influences • 4. Altro adhesive must achieve a 95% or greater transfer of the adhesive to the backing of the tile. 5. Set tile according to diagrams on back of page 6. Roll with a 100lb roller. which is indicated on the label on the carton. If you find that you have The recommended open time for the Ecofix 25 pressure sensitive adhesive is cartons from different production runs, it is highly recommended that you from 30 to 60 minutes open time and with a working time of approximately 2 open cartons and install a mix of tiles from each different production run on hours to set the tiles in place (do not let the open adhesive become contaminated your floor. This will result in a more natural looking floor. with dirt, dust, humidity, condensation, or any other contaminants from the air), Pre-plan the floor by measuring the room first. If the width of the last row is less than 2” inches (5 cm) lay out the room to achieve that the first and the consult your Altro representative or Altro technical if you have any questions. be free from manufacturing defects and will not wear through when installed and the visual size ratio of the space. Installation parallel to the longest wall or • Altro Lavencia Click can also be installed on a radiant heated subfloor. Please Installation in direct sunlight or heavy load areas Measurements • Installation over radiant heated subfloors (commercial) or lifetime (residential), from the date of purchase, your floor will • Services. • other moldings door casings for tiles to fit underneath and leave a minimum 3/16” inch be sanded down or levelled. The surface must be clean of dirt, oil, glue • columns and other abutments, these will be covered later with base or humidity) on all concrete floors. Results are not to exceed <92% IRH for Altro Lavencia Click must be acclimatized. Store flat and fully supported Maintain a small expansion gap (minimum 3/16 of an inch) at all walls, Do not tight fit the tile to door casings, walls, or other abutments, undercut spread gluing is also possible; gluing may be required and recommended during shipping and storage. Remove material from packaging, spread out if • • Do not install Altro Lavencia Click over soft subfloors such as carpet or immediately after setting the tiles roll with a 100lb roller. foam underlayments. last tile are equal in width. for Altro Lavencia Click (sub-floor mat) where there is a need for noise reduction between floors. • Snap lines on the substrate to identify the layout reference points - tiles • successful install. should be set using this reference to ensure tiles are aligned and will lock together correctly. Subfloors • The use of a pull bar and tapping block is recommended to ensure a • Altro Lavencia Click provides a very tight fit. Proper care must be used to In large areas where flooring will span in excess of 40’ long, an expansion ensure all seams are tight at end of install. An unprofessional installation or moisture barrier. Your subfloor should be completely dry prior to installation gap should be used. Otherwise place expansion space in and under the use of improper tools can result in damage to the 5G locking profiles. of the vinyl floor. door thresholds. Cover the expansion space with suitable coverings. Although Altro Lavencia Click is water-resistant, they are not to be used as a • Installing Altro Lavencia Plus? Please use Altro Lavencia installation guide for the plus range. explore altro.com INSTALLATION METHOD OF FLOOR PLANKS OR TILES General and Installation Instructions Harbinger Acoustic Click 5G-C with Bristle Tongue Fig 2. Second plank, first row Place this plank gently and tight to the short end of the4.first one. Fig At the end of the first row, put a distance 5-10 mm, to the wall and measure the length of the Fig 1. last plank to be fit. First plank, first row. General and Installation Instructions Harbinger Acoustic Click 5G-C with Bristle Tongue Place a 5-6 mm thick spacer to the left and position the plank against the wall. Later, after 3 rows, you can easily position the flooring 5-6mm from the wall and install spacers. 1. Start with the first tile in the left corner Fig 5. 7. Fig Fig 3. General. Cut with jig saw, hand knife or laminate cutter. Fold theaplank down in saw, a single movement. Minimum distance between endsaction of planks in During the fold down, make sure the planks are tight parallel rows shall not be less than 50 cm. against each other. Afterwards press or slightly knock at the short end just installed. Cleaning and maintenance guide Initial Maintenance Fig 8a Second plank, second row. Place the plank gently and tight to the short end of the previous plank. 1. Do not begin any maintenance procedure for at least 72 hours after 3. Lower the tile down in a single action 2. Position the following tile as an exact movement. During the fold down, make Fig 7. installation. sure the planks are tight against each other. JuneGeneral. 2014 Page 2 of 8 Afterwards, press or slightly at the width. Work from left to right. one. 2. Sweep and/or vacuum floor surface to remove all loose dust and debris. Minimum distance between ends ofknock planks in Fig 3. rows shall not be less than 50 cm. parallel Fig 2. enddown just installed. 3. Scrub floor with an automatic scrubber (3 in 1 machine) or a standard low Fold theshort plank in a single action movement. Second plank, first row During the fold down, make sure the planks are tight speed swing machine (150rpm to 350rpm) fitted with an Altro Unipad™. Fig 5. Place plankBristle gently Tongue and tight to the short end of Fig5G-C 4.this with General and Installation Instructions Harbinger Acoustic Click Fig 6. against each other.hand saw, knife or laminate cutter. Cut with a jig saw, the one.of the first row, put a distance At first the end General and Installation Instructions Harbinger Acoustic ClickSecond 5G-C with Bristle 4. UsingTongue a 1:40 dilution of AltroClean 44™ with warm, clean water scrub floor row Afterwards press or slightly knock at the short end 5-10 mm, to the wall and measure the length of the Place first plank of minimum length 50 cm. put a just installed. thoroughly. DO NOT FLOOD THE FLOOR. last plank to be fit. spacer against the wall. of the room, Instructions tongue-side facing out from Acoustic the of the first one. Place this tile eneral and Installation Harbinger Click 5G-C extension with Bristle Tongue wall on the length and to the right on the gently and tight to the short end of the first Fig 7. General. Minimum distance between ends of planks in parallel rows shall not be less than 50 cm. Fig 8a 5. Begin the second row with the cut-off Second plank, second row. from the first (start left).end Place the end plank gently androw tight to on thethe short of the previous plank. June 2014 Page 2 of 8 4. Measure and cut to fit the last tile of the row. To do this you can use a utility knife to score the surface at the appropriate point and then break the tile over an edge. Alternatively a vct tile cutter or Miter saw can be 6. Allow at least a 6” stagger for end Fig 3. June 2014 used. seams Fold the plank down in a single action movement. General and Instructions Acoustic Fig 5. Installation During the fold down, make sure Harbinger the planks are tight Click 5G-C with Bristle Tongue Cut with a jig saw, hand saw, knife or laminate cutter. against each other. Afterwards press or slightly knock at the short end Fig 8b Fig 8a FigFold 6. the plank down in a single action just installed. plank, second row. Second Second row with a slight press to the left to movement Place the plank gently and tight to the short end Place first plank minimum the short end ofofthe previouslength plank.50 cm. put a of the previous plank. Fig 9.against the wall. spacer During the fold down, make sure the After 2-3 rows. planksthe aredistance tight against Adjust to theeach wall other. by pulling floor out and placing spacers of 5-6 mm against wall. June 2014 Page 2 of 8 8. Lower the tile while holding the two 7. Starting with the first plank in the row, eneral and Installation Instructions Harbinger Acoustic Click 5G-C with Bristle Tongue together until they are flat and tightly raise the plank at a 45° angle, insert the Fig 8b together. lengthways tongue into the lengthways Fold the plank down in a single action movement with a slight press to the left to groove. June 2014 the short end of the previous plank. FigDuring 6. 9. the fold down, make sure the Fig planksrow are tight against each other. Second After 2-3 rows. Place first plank of minimum length cm. put a Adjust the distance to the wall by50 pulling floor spacer the wall. out against and placing spacers of 5-6 mm against wall. June 2014 June 2014 9. Close the joint using hand pressure, tapping block or pull bar. Fig 8c Press or knock slightly along the short end of the installed plank until a click is heard. Page Do not 3 of 8 force or use mallet on seam. Fig 10. • row How(and to shorten wooden Last perhaps also first doorframes: row). Position a loose plank face down close to Minimum plank width should be at least 5 cm. Remember to allow forand a gap 5-6an mmundercut the doorframe cutofwith to wall. or ajamb saw. Tip! Put spacer before measuring • Fig 8b Fold the plank down in a single action movement with a slight press to the left tooption Maintenance with finish the short end of the previous plank. During the fold down, make sure the Fig 7. planks are tight against each other. General. 1. Follow initial maintenance procedure outlined above. Minimum distance between ends planks 2. Once floor is dry,ofapply twoincoats of Johnson Over & Under®. This will parallel rows shall not be less than 50 cm. seal the floor and only needs to occur once. 3. 4. Allow floor to dry. 10. Adjust the distance to the wall by pulling floor out and placing spacers of June 2014 5-6mm against the wall. Remember to allow for a gap of 5-6mm to wall. Fig 10. Page 3 of 8 Tip: Putperhaps a spaceralso before measuring. Last row (and first row). Cut the tile lengthwise and glue the short ends. Minimum plank width should be at least 5 cm. Remember to allow for a gap of 5-6 mm these to the wall, never to the floor. 6. Allow surface to dry before use. For routine maintenance, sweep/vacuum floor to remove all loose dust and debris then damp mop or machine scrub using Johnson Stride™ according to label instructions. Apply two coats of Johnson Carefree Matte™ floor finish for the desired low Use an auto scrubber fitted with an Altro Unipad or any standard low speed swing machine. gloss look. (2,000 square feet per gallon). Allow the finish to become dry 8. Be sure to remove all wash water and cleaning residue from floor. to the touch, around 45 - 60 minutes, before applying the second coat. 9. Allow surface to dry before use. Fig 8c Fig 8a Apply no more than coatsend within Press or5. knock slightly along the2short of a 24 hour time period. Second plank, second row. the installed plank until a click is heard. Do not Place the plank gently and tight to the short end force or useplank. mallet on seam. of the previous Maintenance without finish option Using an auto scrubber Using a low speed swing machine 1. Sweep and/or vacuum floor surface Page 4 of to 8 remove all loose dust and debris. 1. Sweep and/or vacuum floor surface to remove all loose dust and debris. 2. Add AltroClean 48W in a 1:40 dilution rate into the auto scrubber. 2. Add AltroClean 48W in a 1:40 dilution rate into a mop bucket. 3. Mop the floor with the diluted AltroClean 48W solution and allow a few Fig 8b 3. Fit auto scrubber with white, fine, nylon pads and scrub floor. Fold the plank down in a single action “higher gloss” look movement4.withIfaaslight press to the leftistodesired, wait for the floor to dry thoroughly then the short end ofapply the previous plank. a fine spray of diluted AltroClean 48W (1:40). During the fold down, make sure the a low planks are5.tightUsing against eachspeed other.swing machine (150rpm - 350 rpm) fitted with a white, fine nylon pad buff to a shine. minutes for the cleaner to attack the surface soil. 4. Scrub with low speed swing machine using an Altro Unipad or white, fine nylon pad. 5. Remove excess liquid from floor using a wet vac. 6. If a “higher gloss” look is desired, wait for the floor to dry thoroughly then apply a fine spray of diluted AltroClean 48W (1:40). 7. People can walk on the flooring Install new base or moldings; fasten Ensure the floor is thoroughly rinsed with fresh, clean water. No cleaning residue should remain on the floor. 7. Page 3 of 8 Page 4 of 8 Cut the plank lengthwise and glue the short ends. • If using a standard low-speed swing machine, remove wash water with a wet vac. 6. 7. Using a low speed swing machine (150rpm - 350 rpm) fitted with a white, fine nylon pad buff to a shine. immediately after the installation. Fig 8c Press or knock slightly along the short end of the installed plank until a click is heard. Do not force or use mallet on seam. 11. Minimum tile width should be at least 5cm. 5. Fig 8c Press or knock slightly along the short end of the installed plank until a click is heard. Do not force or use mallet on seam. AltroClean 48W dilution rate: Regular maintenance 1:40 | Heavily soiled floors 1:10
© Copyright 2026 Paperzz